SIP Compliant - CyberData Corporation

Mounting Options
7 Fold Down all Flagnuts (4 Places)
Installation Quick Reference
8 (4Flagnuts
Places)
The IP Endpoint Company
before Inserting into Wall Cutout
Wire &
3 Ground
Network Cable
Custom
2 Gang Box
Enclosure
(Not Provided)
9 Mounting
Screws
(Phillip Drive)
SIP Compliant
6.03 inches
[153mm]
5
011306
1
Network Cable
to J1
Wall
Cutout
2
K.O.
9 Mounting
Screws
(Security
Torx Drive)
Singlewire InformaCast Indoor Intercom Flush Mount
5.28 inches
[134mm]
Parameter
Factory Default Setting
IP Addressing
DHCP
a
Torx Key
6
Intrusion
Sensor
Faceplate
Assembly
Arrow Labels must
Point Upward.
This will Ensure that
the Intrusion Sensor
Functions Properly.
J1
IP Address
10.10.10.10
Web Access Username
admin
Web Access Password
admin
Subnet Maska
255.0.0.0
Default Gatewaya
10.0.0.1
a. Default if there is not a DHCP server present.
Typical System Installation
CreateService
Service
Loop
Loop
4 Create
Inside Gang Box
Inside Custom Enclosure
*More installation and mounting
options are available in the
Operations Guide.
To mount the Intercom:
802.3af Compliant Ethernet Switch
1. Make a wall cutout as shown in the picture.
2. Use a flat blade screwdriver to remove the knockout (KO) of the gang box.
3. Feed the ground wire (shown in the “Ground Connection” section) and the network cable from the wall cutout through the
knockout hole of the gang box.
Intercom
Intercom
Intercom
IP Phone
Informacast Server
4. Create a service loop for both the ground wire and network cable.
Getting Started
5. Plug the network cable into the J1 connector.
•
6. Make sure that the arrow labels on the sides of the gang box are pointing up. This will ensure that the intrusion sensor
functions properly.
Download the Operations Guide PDF file, from the Downloads tab at the following webpage:
http://www.cyberdata.net/voip/011306
•
Create a plan for the locations of your Intercoms.
•
WARNING: This product should be installed by a licensed electrician according to all local electrical and building codes.
8. Tighten the flagnuts with a size #2 Phillips screwdriver.
•
WARNING: To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the installation
instructions.
9. Use a size #2 Phillips screwdriver to secure the Intercom faceplate assembly to the gang box with either Phillips drive
screws or security Torx drive screws.
•
WARNING: The PoE connector is intended for intra-building connections only and does not route to the outside plant.
•
WARNING: This enclosure is not rated for any AC voltages!
7. Fold down all of the flagnuts, and then insert the gang box into the wall cutout.
Contacting CyberData
Intercom Parts
Tool required for assembly: A size #2 Phillips screwdriver
Corporate Headquarters
CyberData Corporation
3 Justin Court
Monterey, CA 93940, USA
Phone: 831-373-2601
Fax: 831-373-4193
http://www.cyberdata.net/
Sales: (831) 373-2601 ext. 334
Support: 831-373-2601 ext. 333
Support Website: http://support.cyberdata.net/
RMA Department: (831) 373-2601 ext. 136
RMA Email: RMA@CyberData.net
RMA Status: http://support.cyberdata.net/
Warranty Information: http://support.cyberdata.net/
© 2017, CyberData Corporation, ALL RIGHTS RESERVED
930937C
(1) Intercom Assembly
(1) Mounting Kit
(1) Optional Mounting Kit
(4) #6 X 3/8-inch,100 Deg.,
Flat Head, Self-Tapping Screw
Quick Reference
Quick Reference
(4) #6 X 3/8-inch,100 Deg.,
Flat Head T15 Security Pin Torx
Screw
930937C
(1) T15 Security Pin Torx Key
© 2017, CyberData Corporation, ALL RIGHTS RESERVED
RTFM Button
Dimensions
RTFM button (SW1)
When the device is operational and linked to a network,
you can use the Reset Test Function Management
(RTFM) button (SW1 [see picture]) to announce the
device’s IP address or restore the device to the factory
default settings.
To announce the device’s current IP address:
0.170 [4.3]
•
Press and release the RTFM button within a five
second window.
Note
The device will use DHCP to obtain the new IP
address (DHCP-assigned address or default to
10.10.10.10 if a DHCP server is not present).
To restore the device to factory default settings:
5.860 [148.8]
•
Press and hold the RTFM button for longer than five
seconds until you hear the device announce that it is
restoring the factory default settings.
Ground Connection
Create Service Loop
inside Gang Box
6.840 [173.7]
Dimensions are in Inches [Millimeter]
Knock Out
2.419 [61.4]
Terminal Block Connections
Alternate Power Input:
1 = +8 to +12VDC @ 1000mA Regulated Power Supply*
2 = Power Ground*
3
Nut
#6 Ring Terminal
4
Wire (IN)
0.25"
Ground Wire Assembly
(Not Provided)
Ground Lug
screwdriver for the terminal block screws
Relay Contact:
(1 A at 30 VDC for continuous loads)
3 = Relay Common
4 = Relay Normally Open Contact
5 = Sense Input
6 = Sense Ground
7 = Remote Switch "A"
8 = Remote Switch "B"
1
8
*Contacts 1 and 2 on the terminal block are only for
powering the device from a non-PoE 12VDC power
source as an alternative to Network PoE power. Use of
these contacts for any other purpose will damage the
device and void the product warranty.
© 2017, CyberData Corporation, ALL RIGHTS RESERVED
Star Washer
Use a 3.17 mm (1/8-inch) flat blade
930937C
Terminal Block
can accept 16 AWG wire
Quick Reference
Quick Reference
930937C
© 2017, CyberData Corporation, ALL RIGHTS RESERVED
Download PDF
Similar pages