wolf new generation design guide - Sub

NEW GENERATION
INTERNATIONAL DESIGN GUIDE
Contents
3
M Series Ovens
12
E Series Ovens
24
Convection Steam Ovens
29
Microwave Ovens
34
Warming Drawers
39
Induction Cooktops
45
Gas Cooktops
51
Coffee Systems
56
Cup Warming Drawer
60
Cooktop Hoods
65
Downdraft Systems
70
Ventilation Recommendations
71
Wolf Warranty
Features and specifications are subject to change at any
time without notice.
IMPORTANT NOTE: Throughout this guide, dimensions may
vary by ± 3 mm.
WOLF M SERIES OVENS
M Series Ovens
Three striking new looks are just the beginning. Superior
performance features include an even more advanced dual
vertical convection fan system, touch-screen controls, convenient new preset cooking programs and improved interior
lighting. There is more usable space inside for deliciousness
on a grand scale. M series ovens can be installed in a standard or flush inset application.
M SERIES OVENS
TRANSITIONAL
ICBSO36TM/S/TH
ICBSO30TM/S/TH
ICBDO30TM/S/TH
PROFESSIONAL
UPPER OVEN
LOWER OVEN
ICBSO30PM/S/PH
ICBDO30PM/S/PH
CONTEMPORARY
ICBSO30CM/B
ICBDO30CM/B
wolfappliance.com
|
3
WOLF M SERIES OVENS
M Series Ovens
TRANSITIONAL SINGLE OVEN
46 mm
218
mm
22
mm
51 mm
36 mm
CONDUIT
CHANNEL
723
mm
W
WIDTH
65
mm
686
mm
584 mm
BEHIND FRAME
OPEN OVEN DOOR
543
mm
TRANSITIONAL DOUBLE OVEN
46 mm
218
mm
22
mm
51 mm
36 mm
CONDUIT
CHANNEL
1254
mm
1291
mm
OPEN OVEN DOOR
W
WIDTH
65
mm
584 mm
BEHIND FRAME
WIDTH
TRANSITIONAL
762 mm Model
914 mm Model (single oven only)
4
|
English
W
759 mm
911 mm
543
mm
WOLF M SERIES OVENS
M Series Ovens
PROFESSIONAL SINGLE OVEN
218
mm
22
mm
46 mm
51 mm
36 mm
723
mm
759 mm
83
mm
CONDUIT
CHANNEL
686
mm
584 mm
BEHIND FRAME
OPEN OVEN DOOR
543
mm
PROFESSIONAL DOUBLE OVEN
UPPER OVEN
46 mm
218
mm
22
mm
LOWER OVEN
51 mm
36 mm
CONDUIT
CHANNEL
1254
mm
1291
mm
OPEN OVEN DOOR
759 mm
83
mm
543
mm
584 mm
BEHIND FRAME
wolfappliance.com
|
5
WOLF M SERIES OVENS
M Series Ovens
CONTEMPORARY SINGLE OVEN
46 mm
218
mm
25
mm
51 mm
36 mm
723
mm
CONDUIT
CHANNEL
686
mm
584 mm
759 mm
OPEN OVEN DOOR
BEHIND FRAME
543
mm
CONTEMPORARY DOUBLE OVEN
46 mm
218
mm
25
mm
51 mm
36 mm
CONDUIT
CHANNEL
1254
mm
1291
mm
OPEN OVEN DOOR
759 mm
584 mm
BEHIND FRAME
6
|
English
543
mm
WOLF M SERIES OVENS
Planning Information
The M series oven can be installed in a standard or flush
inset application. If a cooktop is being installed above an
oven, a minimum of 6 mm is required between units. Location of the electrical supply within the oven opening may
require additional cabinet depth.
Finish the edges of the opening. They may be visible when
the door is open.
For standard installations, face trim will overlap stiles and
rails. Refer to the chart below.
For flush inset installations, a minimum 3 mm reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
BASE SUPPORT
Single Oven
Double Oven
MIN
115 kg
181 kg
ELECTRICAL
Installation must comply with all applicable electrical codes
and be properly grounded (earthed).
Locate the electrical supply flush with the back wall and
within the shaded area shown in the illustration for your specific installation on the following pages. For ease of installation, the electrical supply for the oven can be placed in an
adjacent cabinet within reach of the conduit.
Performance may be compromised if the electrical supply is
less than 220 volts.
The oven is supplied with a single phase and 3-phase
convertible power inlet box. The wiring diagram covering the
control circuit is provided with the oven.
ELECTRICAL REQUIREMENTS
SINGLE OVEN
SINGLE PHASE
3-PHASE
Required Power Supply
Maximum Connected Load
220-240 V AC
50/60 Hz
4.2– 4.8 kW
380-415 V AC
50 Hz
3.0–3.6 kW
DOUBLE OVEN
SINGLE PHASE
3-PHASE
Required Power Supply
220-240 V AC
50/60 Hz
8.4– 9.6 kW
380-415 V AC
50 Hz
4.2–4.8 kW
TRIM OVERLAP
Top
Bottom
Sides
25 mm
0 mm
18 mm
Maximum Connected Load
wolfappliance.com
|
7
WOLF M SERIES OVENS
M Series Single Oven
STANDARD INSTALLATION
591 mm
OPENING
DEPTH
TOP VIEW
127
mm
E
102
mm
699 mm
W
OPENING
HEIGHT
OPENING WIDTH
E
E
SIDE VIEW
FRONT VIEW
NOTE: Location of electrical supply within opening may require additional cabinet depth.
Dashed line represents profile of unit.
OPENING WIDTH
SINGLE OVEN
762 mm Model
914 mm Model
8
|
English
W
724 mm
876 mm
WOLF M SERIES OVENS
M Series Double Oven
STANDARD INSTALLATION
591 mm
OPENING
DEPTH
TOP VIEW
127
mm
E
102
mm
1267 mm
W
OPENING
HEIGHT
OPENING WIDTH
E
E
432 mm
TYPICAL
SIDE VIEW
FRONT VIEW
NOTE: Location of electrical supply within opening may require additional cabinet depth.
Dashed line represents profile of unit.
OPENING WIDTH
DOUBLE OVEN
762 mm Model
W
724 mm
wolfappliance.com
|
9
WOLF M SERIES OVENS
M Series Single Oven
FLUSH INSET INSTALLATION
22 mm
610 mm
OR
FLUSH INSET
DEPTH
25 mm**
FINISHED
CLEATS*
TOP VIEW
W
FLUSH INSET WIDTH***
127
29 mm mm
E
102
mm
730 mm
FLUSH INSET
HEIGHT***
21 mm
E
3 mm
SIDE VIEW
FRONT VIEW
*25 mm minimum depth. Shaded areas will be visible and should be finished to match cabinetry.
** 22 mm for professional and transitional models and 25 mm for contemporary model.
***Dimension provides minimum reveals.
NOTE: Location of electrical supply within opening may require additional cabinet depth.
Dashed line represents profile of unit.
FLUSH INSET WIDTH
SINGLE OVEN
762 mm Model
914 mm Model
10
|
English
W
765 mm
918 mm
E
WOLF M SERIES OVENS
M Series Double Oven
FLUSH INSET INSTALLATION
22 mm
610 mm
OR
FLUSH INSET
DEPTH
25 mm**
FINISHED
CLEATS*
TOP VIEW
W
FLUSH INSET WIDTH***
127
29 mm mm
E
102
mm
1299 mm
FLUSH INSET
HEIGHT***
21 mm
E
3 mm
E
432 mm
TYPICAL
SIDE VIEW
FRONT VIEW
*25 mm minimum depth. Shaded areas will be visible and should be finished to match cabinetry.
** 22 mm for professional and transitional models and 25 mm for contemporary model.
***Dimension provides minimum reveals.
NOTE: Location of electrical supply within opening may require additional cabinet depth.
Dashed line represents profile of unit.
FLUSH INSET WIDTH
DOUBLE OVEN
762 mm Model
W
765 mm
wolfappliance.com
|
11
WOLF E SERIES OVENS
E Series Ovens
Stainless models now feature a redesigned stainless steel
touch-action control panel, helping to create great meals
with ease, as well as adding a striking design feature to the
kitchen. Smart technology gives the E series ten cooking
modes, with Wolf’s innovative dual convection in single
ovens and in the upper unit of double ovens. Wolf E series
ovens are crafted of stainless steel. Tubular handles have
been updated to match the rest of the new Wolf cooking
appliance offering, providing a more cohesive family look.
E series ovens can be installed in a standard or flush inset
application.
E SERIES OVENS
TRANSITIONAL
WARM
WATER
LIGHT
TEMP
MODE
OK
TIMER
TIME
LIGHT
TEMP
MODE
OK
TIMER
TIME
OFF
OFF
ICBSO2418TE/S/TH
ICBSO24TE/S/TH
ICBSO30TE/S/TH
ICBDO30TE/S/TH
PROFESSIONAL
ICBSO30PE/S/PH
ICBDO30PE/S/PH
CONTEMPORARY
ICBSO30CE/B/TH
ICBDO30CE/B/TH
12
|
English
WOLF E SERIES OVENS
610 mm E Series Ovens
MODEL ICBSO2418TE/S/TH TRANSITIONAL SINGLE OVEN
538 mm
22 mm
WATER
LIGHT
TEMP
MODE
OK
TIMER
TIME
OFF
446
mm
454
mm
597 mm
64
mm
546 mm
BEHIND FRAME
OPEN OVEN DOOR
360
mm
MODEL ICBSO24TE/S/TH TRANSITIONAL SINGLE OVEN
22 mm
WARM
LIGHT
TEMP
MODE
OK
TIMER
TIME
559 mm
OFF
591
mm
597
mm
597 mm
64
mm
546 mm
BEHIND FRAME
OPEN OVEN DOOR
460
mm
wolfappliance.com
|
13
WOLF E SERIES OVENS
762 mm E Series Ovens
TRANSITIONAL SINGLE OVEN
244
mm
25 mm
76 mm
708
mm
CONDUIT
CHANNEL
225
mm
689
mm
718 mm
759 mm
70
mm
603 mm
BEHIND FRAME
OPEN OVEN DOOR
559
mm
TRANSITIONAL DOUBLE OVEN
244
mm
25 mm
76 mm
1280
mm
CONDUIT
CHANNEL
225
mm
1261
mm
718 mm
OPEN OVEN DOOR
759 mm
14
|
English
70
mm
603 mm
BEHIND FRAME
559
mm
WOLF E SERIES OVENS
762 mm E Series Ovens
PROFESSIONAL SINGLE OVEN
244
mm
25 mm
76 mm
708
mm
CONDUIT
CHANNEL
225
mm
689
mm
718 mm
759 mm
86
mm
603 mm
BEHIND FRAME
OPEN OVEN DOOR
559
mm
PROFESSIONAL DOUBLE OVEN
244
mm
25 mm
76 mm
1280
mm
CONDUIT
CHANNEL
225
mm
1261
mm
718 mm
OPEN OVEN DOOR
759 mm
86
mm
559
mm
603 mm
BEHIND FRAME
wolfappliance.com
|
15
WOLF E SERIES OVENS
762 mm E Series Ovens
CONTEMPORARY SINGLE OVEN
32 mm
244
mm
76 mm
708
mm
CONDUIT
CHANNEL
225
mm
687
mm
718 mm
759 mm
76
mm
603 mm
BEHIND FRAME
OPEN OVEN DOOR
559
mm
CONTEMPORARY DOUBLE OVEN
32 mm
244
mm
76 mm
1280
mm
CONDUIT
CHANNEL
225
mm
1257
mm
718 mm
OPEN OVEN DOOR
759 mm
16
|
English
76
mm
603 mm
BEHIND FRAME
559
mm
WOLF E SERIES OVENS
Planning Information
The E series oven can be installed in a standard or flush
inset application. If a cooktop is being installed above an
oven, a minimum of 6 mm is required between units. Location of the electrical supply within the oven opening may
require additional cabinet depth.
Finish the edges of the opening. They may be visible when
the door is open.
For standard installations, face trim will overlap stiles and
rails. Refer to the chart below.
For flush inset installations, a minimum 6 mm reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
ELECTRICAL
Installation must comply with all applicable electrical codes
and be properly grounded (earthed).
Locate the electrical supply flush with the back wall and
within the shaded area shown in the illustration for your specific installation on the following pages. For ease of installation, the electrical supply for the oven can be placed in an
adjacent cabinet within reach of the conduit. Unit is supplied
with terminal box convertible to single or 3-phase.
The wiring diagram covering the control circuit is provided
with the oven.
ELECTRICAL REQUIREMENTS
INSTALLATION REQUIREMENTS
610 mm SINGLE OVEN
BASE SUPPORT
MIN
610 mm Single Oven
762 mm Single Oven
762 mm Double Oven
TRIM OVERLAP
Top
Bottom
Sides
68 kg
115 kg
181 kg
610 mm MODEL
762 mm MODEL
6 mm
0 mm
17 mm
13 mm
3 mm
17 mm
Electrical Supply
Service
Receptacle
Power Cord
220-240 V AC, 50 Hz
3400 Watts
grounding-type (earthed)
1.8 m
ELECTRICAL REQUIREMENTS
762 mm SINGLE OVEN
SINGLE PHASE
3-PHASE
Required Power Supply
Maximum Connected Load
Total Amps
220-240 V AC
50/60 Hz
4.4 kW
19
380-415 V AC
50 Hz
4.4 kW
19
762 mm DOUBLE OVEN
SINGLE PHASE
3-PHASE
Required Power Supply
220-240 V AC
50/60 Hz
7.4 kW
32
380-415 V AC
50 Hz
5.1 kW
22
Maximum Connected Load
Total Amps
wolfappliance.com
|
17
WOLF E SERIES OVENS
610 mm E Series Oven
STANDARD INSTALLATION
572 mm
OPENING
DEPTH
TOP VIEW
E
E
H
OPENING
HEIGHT
562 mm
OPENING WIDTH
SIDE VIEW
FRONT VIEW
NOTE: Electrical supply must be located in adjacent cabinet within .9 m of opening.
OPENING HEIGHT
610 mm E SERIES OVEN
Model ICBSO2418TE/S/TH
Model ICBSO24TE/S/TH
18
|
English
H
449 mm
591 mm
WOLF E SERIES OVENS
762 mm E Series Single Oven
STANDARD INSTALLATION
610 mm
OPENING
DEPTH
TOP VIEW
127
mm
692 mm
OPENING
HEIGHT
E
102
mm
724 mm
OPENING WIDTH
E
E
SIDE VIEW
FRONT VIEW
NOTE: Location of electrical supply within opening may require additional cabinet depth.
Dashed line represents profile of unit.
wolfappliance.com
|
19
WOLF E SERIES OVENS
762 mm E Series Double Oven
STANDARD INSTALLATION
610 mm
OPENING
DEPTH
TOP VIEW
127
mm
E
102
mm
1264 mm
OPENING
HEIGHT
724 mm
OPENING WIDTH
E
E
432 mm
TYPICAL
SIDE VIEW
NOTE: Location of electrical supply within opening may require additional cabinet depth.
Dashed line represents profile of unit.
20
|
English
FRONT VIEW
WOLF E SERIES OVENS
610 mm E Series Oven
FLUSH INSET INSTALLATION
584 mm
FLUSH
INSET
DEPTH
22 mm
FINISHED
CLEATS*
TOP VIEW
13 mm
E
E
H
FLUSH INSET
HEIGHT**
24 mm
6 mm
610 mm
FLUSH INSET WIDTH**
SIDE VIEW
FRONT VIEW
*Will be visible and should be finished to match cabinetry.
**Dimension provides minimum reveals.
NOTE: Electrical supply must be located in adjacent cabinet within .9 m of opening.
FLUSH INSET HEIGHT
610 mm E SERIES OVEN
Model ICBSO2418TE/S/TH
Model ICBSO24TE/S/TH
H
467 mm
610 mm
wolfappliance.com
|
21
WOLF E SERIES OVENS
762 mm E Series Single Oven
FLUSH INSET INSTALLATION
25 mm
635 mm
OR
FLUSH INSET
DEPTH
32 mm**
FINISHED
CLEATS*
TOP VIEW
772 mm
FLUSH INSET WIDTH***
127
19 mm mm
E
102
mm
721 mm
FLUSH INSET
HEIGHT***
24 mm
E
10 mm
981 mm
TYPICAL
SIDE VIEW
*Will be visible and should be finished to match cabinetry.
**25 mm for professional and transitional models and 32 mm for contemporary model.
***Dimension provides minimum reveals.
NOTE: Location of electrical supply within opening may require additional cabinet depth.
Dashed line represents profile of unit.
22
|
English
FRONT VIEW
E
WOLF E SERIES OVENS
762 mm E Series Double Oven
FLUSH INSET INSTALLATION
25 mm
635 mm
OR
FLUSH INSET
DEPTH
32 mm**
FINISHED
CLEATS*
TOP VIEW
772 mm
FLUSH INSET WIDTH***
127
19 mm mm
E
102
mm
1292 mm
FLUSH INSET
HEIGHT***
24 mm
E
10 mm
E
432 mm
TYPICAL
SIDE VIEW
FRONT VIEW
*Will be visible and should be finished to match cabinetry.
**25 mm for professional and transitional models and 32 mm for contemporary model.
***Dimension provides minimum reveals.
NOTE: Location of electrical supply within opening may require additional cabinet depth.
Dashed line represents profile of unit.
wolfappliance.com
|
23
WOLF CONVECTION STEAM OVENS
Convection Steam Ovens
The legacy of the “combination oven” goes back decades,
to innovative chefs in America and Europe who embraced
the combination of air movement with superheated steam to
achieve superior results—from breads and roasts to delicate
fishes, seafood and vegetables. Wolf combines the benefits
of convection and steam for the most innovative steam oven
on the market today. Virtually any dish prepared in a conventional oven, range or microwave can also be prepared
in the Wolf convection steam oven—with more control. Two
widths and three distinct styles compliment the look of Wolf
ovens, ranges and cooktops. Convection steam ovens can
be installed in a standard or flush inset application.
CONVECTION STEAM OVENS
TRANSITIONAL
WATER
LIGHT
TEMP
MODE
OK
TIMER
TIME
OFF
ICBCSO24TE/S/TH
PROFESSIONAL
ICBCSO30PM/S/PH
CONTEMPORARY
ICBCSO30CM/B/TH
24
|
English
ICBCSO30TM/S/TH
ICBCSO30PE/S/PH
ICBCSO30TE/S/TH
WOLF CONVECTION STEAM OVENS
Convection Steam Ovens
TRANSITIONAL
538 mm
22 mm
446
mm
454
mm
W
WIDTH
64
mm
546 mm
BEHIND FRAME
OPEN OVEN DOOR
360
mm
WIDTH
TRANSITIONAL
W
610 mm Model
762 mm Model
597 mm
759 mm
PROFESSIONAL
22 mm
446
mm
454
mm
759 mm
83
mm
538 mm
546 mm
BEHIND FRAME
OPEN OVEN DOOR
360
mm
CONTEMPORARY
22 mm
446
mm
454
mm
759 mm
64
mm
538 mm
546 mm
BEHIND FRAME
OPEN OVEN DOOR
360
mm
wolfappliance.com
|
25
WOLF CONVECTION STEAM OVENS
Planning Information
The convection steam oven can be installed in a standard
or flush inset application. The electrical supply for the oven
must be located in an adjacent cabinet.
Finish the edges of the opening. They may be visible when
the door is open.
For standard installations, face trim will overlap stiles and
rails. Refer to the chart below.
For flush inset installations, a minimum 3 mm reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
MIN
Convection Steam Oven
Top
Bottom
Sides
26
|
English
Installation must comply with all applicable electrical codes
and be properly grounded (earthed).
Locate the electrical supply as shown in the illustrations
on the following pages. A separate circuit, servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
Performance may be compromised if the electrical supply is
less than 220 volts.
ELECTRICAL REQUIREMENTS
BASE SUPPORT
TRIM OVERLAP
ELECTRICAL
45 kg
610 mm MODEL
762 mm MODEL
5 mm
0 mm
18 mm
5 mm
0 mm
98 mm
Electrical Supply
Service
220-240 V AC, 50 Hz
3800 Watts
Receptacle
grounding-type (earthed)
Power Cord
1.8 m
WOLF CONVECTION STEAM OVENS
Convection Steam Oven
STANDARD INSTALLATION
548 mm
OPENING
DEPTH
TOP VIEW
E
E
449 mm
OPENING
HEIGHT
W
OPENING WIDTH
SIDE VIEW
FRONT VIEW
NOTE: 610 mm and 762 mm models require the same opening dimensions.
Electrical supply must be located in adjacent cabinet within .9 m of opening.
Dashed line represents profile of unit.
OPENING WIDTH
CONVECTION STEAM OVEN
610 mm Model
762 mm Model
W
562 mm
562 mm
wolfappliance.com
|
27
WOLF CONVECTION STEAM OVENS
Convection Steam Oven
FLUSH INSET INSTALLATION
584 mm
25 mm
FLUSH INSET
DEPTH
FINISHED
CLEATS*
TOP VIEW
E
E
8 mm
460 mm
FLUSH INSET
HEIGHT**
A
3 mm
W
FLUSH INSET WIDTH**
SIDE VIEW
FRONT VIEW
*Will be visible and should be finished to match cabinetry.
**Dimension provides minimum reveals.
NOTE: Electrical supply must be located in adjacent cabinet within .9 m of opening.
Dashed line represents profile of unit.
FLUSH INSET WIDTH
CONVECTION STEAM OVEN
610 mm Model
762 mm Model
28
|
English
W
A
603 mm
765 mm
21 mm
102 mm
WOLF MICROWAVE OVENS
Microwave Ovens
As true cooking instruments, Wolf microwave ovens have
features that make fast meals better meals. New drop down
door microwaves feature a door that hinges at the bottom.
Drop down door microwaves are designed to match Wolf
transitional, professional and contemporary products.
Microwave ovens can be installed in a standard or flush
inset application.
DROP DOWN DOOR MICROWAVES
TRANSITIONAL
ICBMDD24TE/S/TH
ICBMDD30TM/S/TH
ICBMDD30TE/S/TH
PROFESSIONAL
ICBMDD30PM/S/PH
ICBMDD30PE/S/PH
CONTEMPORARY
ICBMDD30CM/B/TH
wolfappliance.com
|
29
WOLF MICROWAVE OVENS
Drop Down Door Microwave Ovens
TRANSITIONAL
538 mm
22 mm
446
mm
454
mm
W
WIDTH
64
mm
546 mm
BEHIND FRAME
OPEN OVEN DOOR
360
mm
WIDTH
TRANSITIONAL
W
610 mm Model
762 mm Model
597 mm
759 mm
PROFESSIONAL
22 mm
446
mm
454
mm
759 mm
83
mm
538 mm
546 mm
BEHIND FRAME
OPEN OVEN DOOR
360
mm
CONTEMPORARY
22 mm
446
mm
454
mm
759 mm
64
mm
538 mm
546 mm
BEHIND FRAME
OPEN OVEN DOOR
30
|
English
360
mm
WOLF MICROWAVE OVENS
Planning Information
Electrical
DROP DOWN DOOR MICROWAVE
Installation must comply with all applicable electrical codes
and be properly grounded (earthed).
The drop down door microwave oven can be installed in a
standard or flush inset application.
Finish the edges of the opening. They may be visible when
the door is open.
For standard installations, face trim will overlap stiles and
rails. Refer to the chart below.
For flush inset installations, a minimum 3 mm reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
BASE SUPPORT
MIN
Drop Down Door Microwave
TRIM OVERLAP
Top
Bottom
Sides
57 kg
610 mm MODEL
762 mm MODEL
5 mm
0 mm
18 mm
5 mm
0 mm
98 mm
Locate the electrical supply as shown in the illustrations on
the following pages. The receptacle may also be located
in an adjacent cabinet within reach of the power cord. A
separate circuit, servicing only this appliance is required. A
ground fault circuit interrupter (GFCI) is not recommended
and may cause interruption of operation. Refer to the illustration below for minimum power cord plug clearance.
ELECTRICAL REQUIREMENTS
Electrical Supply
220-240 V AC, 50/60 Hz
Service
15 amp dedicated circuit
Receptacle
grounding-type (earthed)
Power Cord
1.2 m
wolfappliance.com
|
31
WOLF MICROWAVE OVENS
Drop Down Door Microwave Oven
STANDARD INSTALLATION
548 mm
OPENING
DEPTH
TOP VIEW
E
449 mm
OPENING
HEIGHT
W
OPENING WIDTH
SIDE VIEW
FRONT VIEW
NOTE: 610 mm and 762 mm models require the same opening dimensions.
Dashed line represents profile of unit.
OPENING WIDTH
DROP DOWN DOOR MICROWAVE
610 mm Model
762 mm Model
32
|
English
W
562 mm
562 mm
WOLF MICROWAVE OVENS
Drop Down Door Microwave Oven
FLUSH INSET INSTALLATION
584 mm
25 mm
FLUSH INSET
DEPTH
FINISHED
CLEATS*
TOP VIEW
E
8 mm
460 mm
FLUSH INSET
HEIGHT**
A
3 mm
W
FLUSH INSET WIDTH**
SIDE VIEW
FRONT VIEW
*Will be visible and should be finished to match cabinetry.
**Dimension provides minimum reveals.
NOTE: Dashed line represents profile of unit.
FLUSH INSET WIDTH
DROP DOWN DOOR MICROWAVE
610 mm Model
762 mm Model
W
A
603 mm
765 mm
21 mm
102 mm
wolfappliance.com
|
33
WOLF WARMING DRAWERS
Warming Drawers
Wolf warming drawers are designed to take care of prepared foods until it’s time to serve them. You can adjust the
temperature, keeping moist foods moist and crisp foods
crisp. Warming drawers are ideal for proofing dough. Drawer
fronts are available to match the look of Wolf ovens and
sealed burner rangetops. The integrated drawer front allows
for a custom wood panel and handle.
WARMING DRAWER FRONTS
M / E SERIES
Transitional
INTEGRATED
KEY FEATURES
•850-watt heating element with temperature control range
of 25°C to 95°C.
•Spacious 42 L interior capacity.
•Preset, four-hour automatic shutoff.
•Hidden electronic touch controls for sleek appearance.
•Ball-bearing drawer glides for smooth, full extension.
•Accessory six-piece container set available.
34
|
English
Custom Panel
Professional
Contemporary
WOLF WARMING DRAWERS
Warming Drawers
DRAWER FRONT OPTIONS
DIMENSIONS
Wolf warming drawer fronts allow for many design options,
but the warming drawer itself will be the same for all applications. A panel mounting kit is required when installing a
custom panel. The panel mounting kit is available through
an authorized Wolf dealer.
A
264
mm
W
The 51 mm thick drawer front, in 762 mm and 914 mm
widths, is designed to be installed below a sealed burner
rangetop, so the panel aligns properly with the front of the
rangetop. Dimensions for the warming drawer remain the
same, even though the drawer front may be wider to match
a Wolf 914 mm oven or sealed burner rangetop.
229
mm
B
WIDTH
578 mm
718 mm
OPEN DRAWER
546
mm
DRAWER FRONT
MODEL
W
762 mm Drawer Front
914 mm Drawer Front
759 mm
911 mm
M SERIES
Transitional / Professional
Contemporary
E SERIES
Transitional / Professional
Professional (51 mm thick)
Contemporary
A
B
22 mm
25 mm
83 mm
86 mm
A
B
29 mm
54 mm
35 mm
89 mm
114 mm
95 mm
INTEGRATED DRAWER FRONT
CUSTOM PANEL
Typical Dimensions
Min Thickness
W
H
D
759 mm
264 mm
19 mm
16 mm
wolfappliance.com
|
35
WOLF WARMING DRAWERS
Planning Information
The warming drawer must be installed with a Wolf drawer
front, avail­able through an authorized Wolf dealer. Specific
installation instructions are included with the drawer front.
The warming drawer can be installed in a standard or flush
inset application.
For a standard installation, the drawer collar and front panel
sit proud of the cabinet face frame. A recessed installation
requires the cabinetry be recessed by 5 mm so the collar is
flush with the cabinet face frame but the drawer front will
sit proud. A flush inset installation requires the drawer collar
and front panel be recessed to be flush with surrounding
cabinetry. Refer to illustrations on the following pages for
minimum cabinet dimensions for your specific installation.
Finish the edges of the opening. They may be visible when
the drawer is open.
For standard installations, face trim will overlap stiles and
rails. Refer to the chart below.
For flush inset installations, a minimum 3 mm reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
BASE SUPPORT
Warming Drawer
MIN
90 kg
TRIM OVERLAP
Top, Bottom and Sides
36
|
English
16 mm
ELECTRICAL
Installation must comply with all applicable electrical codes
and be properly grounded (earthed).
Locate the electrical supply flush with the back wall and
within the shaded area shown in the illustrations on the
following pages. For ease of installation, the electrical
supply for the warming drawer can be placed in an adjacent
cabinet within reach of the power cord.
ELECTRICAL REQUIREMENTS
Electrical Supply
220-240 V AC, 50/60 Hz
Service
15 amp dedicated circuit
Receptacle
grounding-type (earthed)
Power Cord
.9 m
WOLF WARMING DRAWERS
Warming Drawer
STANDARD INSTALLATION
584 mm
OPENING
DEPTH
TOP VIEW
ANTI-TIP BLOCK
232 mm
OPENING
HEIGHT
E
727 mm
OPENING WIDTH
SIDE VIEW
FRONT VIEW
NOTE: Location of electrical supply within opening may require additional cabinet depth.
wolfappliance.com
|
37
WOLF WARMING DRAWERS
Warming Drawer
FLUSH INSET INSTALLATION
A
DRAWER
FRONT
DEPTH
610 mm
FLUSH INSET
DEPTH
FINISHED
CLEATS*
TOP VIEW
ANTI-TIP BLOCK
19 mm
270 mm
FLUSH INSET
HEIGHT**
19 mm
E
19 mm
765 mm
FLUSH INSET WIDTH**
SIDE VIEW
FRONT VIEW
*Will be visible and should be finished to match cabinetry.
**Dimension provides minimum reveals.
NOTE: Location of electrical supply within opening may require additional cabinet depth.
DRAWER FRONT DEPTH
A
Transitional / Professional
Professional (51 mm thick)
Contemporary
M SERIES
E SERIES
22 mm
NA
25 mm
29 mm
54 mm
35 mm
Custom front panel depth is dependent on panel thickness.
38
|
English
E
WOLF INDUCTION COOKTOPS
Induction Cooktops
Ultrafast. Exceptionally energy efficient. Induction cooking
has been popular among European chefs and homeowners for decades. Now Wolf leads the way in bringing
this remarkable technology to North American kitchens.
Its secret is magnetism. Electromagnetic elements cause
iron and magnetic stainless cookware to heat up instantly
and with perfectly distributed heat. Heat generation stops
the instant you turn off the element or remove the pan. The
cooktop’s surface remains cool. Your kitchen stays cooler
too. Transitional models have stainless steel trim. Contemporary models can be mounted flush with the countertop.
INDUCTION COOKTOPS
TRANSITIONAL
ICBCI152T/S
ICBCI304T/S
ICBCI365T/S
CONTEMPORARY
ICBCI243C/B
ICBCI304C/B
ICBCI365C/B
wolfappliance.com
|
39
WOLF INDUCTION COOKTOPS
Induction Cooktops
381 mm TRANSITIONAL
762 mm TRANSITIONAL
914 mm TRANSITIONAL
533
mm
533
mm
762 mm
381 mm
51 mm
CONDUIT
32
mm
914 mm
CONDUIT
22
mm
32 mm
610 mm CONTEMPORARY
51 mm
600 mm
32 mm
762 mm CONTEMPORARY
22
mm
32 mm
216 mm
152 mm
610 mm INDUCTION COOKTOP
267 mm
(2) 203 mm
762 mm INDUCTION COOKTOP
267 mm
(2) 203 mm
152 mm
914 mm INDUCTION COOKTOP
267 mm
(4) 203 mm
|
English
W
2300 / 3150 boost
1400
W
2600 / 3150 boost
2100 / 3000 boost
W
2600 / 3150 boost
2100 / 3000 boost
1400
W
2600 / 3700 boost
2100 / 3000 boost
533
mm
914 mm
CONDUIT
ELEMENT RATING
381 mm INDUCTION COOKTOP
22
mm
533
mm
64 mm
51 mm
914 mm CONTEMPORARY
762 mm
CONDUIT
32 mm
CONDUIT
22
mm
533
mm
40
533
mm
22
mm
64 mm
CONDUIT
32 mm
22
mm
64 mm
WOLF INDUCTION COOKTOPS
Planning Information
A minimum height clearance of 159 mm is required from the
top of the countertop to any combustible surface directly
below the cooktop.
Contemporary induction cooktops can be mounted flush
with the top of the countertop, or as a frameless standard
installation sitting on top of the countertop surface. If the
cooktop is to be mounted flush with the countertop, a
recessed area surrounding the cooktop cut-out must be
provided. Wolf downdraft systems cannot be used with
contemporary induction cooktops.
IMPORTANT NOTE: Flush mount installations are intended
for granite, solid surface or stone countertop surfaces only.
ELECTRICAL
Installation must comply with all applicable electrical codes
and be properly grounded (earthed).
Locate the electrical supply as shown in the illustrations on
the following pages. A separate circuit, servicing only this
appliance is required.
Performance may be compromised if the electrical supply is
less than 220 volts.
ELECTRICAL REQUIREMENTS
INDUCTION COOKTOPS
SINGLE PHASE
3-PHASE
Required Power Supply
220-240 V AC
50/60 Hz
380-415 V AC
50 Hz
TOTAL AMPS
SINGLE PHASE
3-PHASE
16
30
32
48
16
16
16
16
381 mm Induction
610 mm Induction
762 mm Induction
914 mm Induction
wolfappliance.com
|
41
WOLF INDUCTION COOKTOPS
381 mm Cooktops
STANDARD INSTALLATION
64 mm
356
mm
495
mm
64 mm
COUNTERTOP CUT-OUT
330
mm
457
mm
762
mm
51
mm
E
914 mm min
FLOOR TO
COUNTERTOP
SIDE VIEW
FRONT VIEW
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
combustible materials cannot be located within this area.
42
|
English
WOLF INDUCTION COOKTOPS
610 mm, 762 mm and 914 mm Cooktops
STANDARD INSTALLATION
64 mm
W
495
mm
WIDTH
64 mm
COUNTERTOP CUT-OUT
330
mm
457
mm
762
mm
51
mm
114 mm
89 mm
E
254 mm
914 mm min
FLOOR TO
COUNTERTOP
SIDE VIEW
FRONT VIEW
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
combustible materials cannot be located within this area.
Electrical supply location only applies to installations with built-in oven.
CUT-OUT WIDTH
INDUCTION COOKTOP
610 mm
762 mm
914 mm
W
562 mm
737 mm
889 mm
wolfappliance.com
|
43
WOLF INDUCTION COOKTOPS
610 mm, 762 mm and 914 mm Cooktops
FLUSH INSTALLATION
64 mm
COUNTERTOP
PROFILE
22
mm MAX
W
537 mm
495
mm
CUT-OUT WIDTH
RECESS
A
RECESS
8 mm
64 mm
40 mm min
COUNTERTOP CUT-OUT
330
mm
457
mm
762
mm
51
mm
114 mm
89 mm
E
254 mm
914 mm min
FLOOR TO
COUNTERTOP
SIDE VIEW
FRONT VIEW
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
combustible materials cannot be located within this area.
Electrical supply location only applies to installations with built-in oven.
Outside corner radius 11 mm.
CUT-OUT WIDTH
INDUCTION COOKTOP
610 mm
762 mm
914 mm
44
|
English
W
A
562 mm
737 mm
889 mm
603 mm
765 mm
918 mm
WOLF GAS COOKTOPS
Gas Cooktops
New performance enhancements make delicious results
even more of a certainty than ever. Multiple sizes, choice of
knob colors, distinctly different grates, and even a new way
to integrate with custom cabinetry—the new gas cooktops
offer exceptional design flexibility.
GAS COOKTOPS
TRANSITIONAL
ICBCG152T/S
ICBCG304T/S
ICBMM15T/S
ICBCG365T/S
PROFESSIONAL
ICBCG304P/S
ICBCG365P/S
wolfappliance.com
|
45
WOLF GAS COOKTOPS
Gas Cooktops
381 mm TRANSITIONAL MULTIFUNCTION
381 mm TRANSITIONAL
533
mm
533
mm
381
mm
381
mm
102 mm
127 mm
22 mm
22 mm
914 mm TRANSITIONAL
762 mm TRANSITIONAL
533
mm
533
mm
914 mm
762 mm
102 mm
102 mm
22 mm
22 mm
BURNER RATING
381 mm TRANSITIONAL
KW
Medium
Small
3.5
2.7
381 mm TRANSITIONAL MULTIFUNCTION
KW
Burner
8.0
762 mm TRANSITIONAL
KW
Large
Medium
(2) Small
5.3
3.5
2.7
914 mm TRANSITIONAL
KW
Large
Medium
(3) Small
5.3
3.5
2.7
46
|
English
WOLF GAS COOKTOPS
Gas Cooktops
762 mm PROFESSIONAL
914 mm PROFESSIONAL
533
mm
533
mm
914 mm
762 mm
102 mm
102 mm
22 mm
22 mm
BURNER RATING
762 mm PROFESSIONAL
KW
Large
Medium
(2) Small
5.3
3.5
2.7
914 mm PROFESSIONAL
KW
Large
Medium
(3) Small
5.3
3.5
2.7
wolfappliance.com
|
47
WOLF GAS COOKTOPS
Planning Information
A minimum 51 mm is required from the bottom of the
cooktop to combustible materials. If a cooktop is installed
above an oven, a minimum of 6 mm is required between
units.
ELECTRICAL
Installation must comply with all applicable electrical codes
and be properly grounded (earthed).
Locate the electrical supply as shown in the illustration
on the following pages. A separate circuit, servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
Electrical Supply
220-240 V AC, 50/60 Hz
Service
10 amp dedicated circuit
Receptacle
grounding-type (earthed)
Power Cord
1.8 m
|
English
A gas supply line of 19 mm rigid pipe must be provided
to the cooktop. If local codes permit, a certified, .9 m long,
13 mm or 19 mm ID flexible metal appliance connector is
recommended to connect the units 1/2" NPT (or ISO 7/1)
male inlet to the gas supply line.
Wolf natural gas cooktops will function up to 3124 m in altitude without adjustment and LP gas cooktops will function
up to 2621 m. If the installation exceeds these elevations,
contact an authorized Wolf dealer for a high altitude conversion kit.
GAS REQUIREMENTS
NATURAL GAS
Supply Pressure
ELECTRICAL REQUIREMENTS
48
GAS SUPPLY
LP GAS
Supply Pressure
WC
25 mb
WC
37 mb
WOLF GAS COOKTOPS
381 mm Transitional Gas and Multifunction Cooktops
STANDARD INSTALLATION
64 mm
356
mm
495
mm
64 mm
COUNTERTOP CUT-OUT
330
mm
457
mm
762
mm
178
mm
E
127
mm
G
ELECTRICAL
AND GAS FLOOR
LOCATION
SIDE VIEW
FRONT VIEW
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
combustible materials cannot be located within this area.
wolfappliance.com
|
49
WOLF GAS COOKTOPS
762 and 914 mm Transitional and Professional Gas Cooktops
STANDARD INSTALLATION
64 mm
W
495
mm
WIDTH
64 mm
COUNTERTOP CUT-OUT
330
mm
457
mm
762
mm
229
mm
102 mm
89 mm
E
G
254 mm
SIDE VIEW
FRONT VIEW
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
combustible materials cannot be located within this area.
Electrical and gas supply location only applies to installations with built-in oven.
CUT-OUT WIDTH
TRANSITIONAL AND PROFESSIONAL
762 mm Model
914 mm Model
50
|
English
W
737 mm
889 mm
WOLF COFFEE SYSTEMS
Coffee Systems
Make professional-quality brewed coffee, espresso,
cappuccino, latte and more. The Wolf coffee system
automatically steams and foams the milk perfectly. Water
temperature and brew strength are adjustable. Uses either
whole-bean or ground coffee. The design pairs beautifully,
either side-by-side or in a tower application, with other
Wolf products such as the convection steam oven. Coffee
systems can be installed in a standard or flush inset
application. All 762 mm trim options are based on model
ICBEC24/B.
COFFEE SYSTEMS
610 mm MODELS
ICBEC24/B
ICBEC24/S
TRANSITIONAL
With 762 mm
M Series Trim
With 762 mm
E Series Trim
PROFESSIONAL
With 762 mm
M Series Trim
With 762 mm
E Series Trim
CONTEMPORARY
With 762 mm
M / E Series Trim
wolfappliance.com
|
51
WOLF COFFEE SYSTEMS
Coffee System
DIMENSIONS
22 mm
454
mm
W
WIDTH
394 mm
UNIT
FULL EXTENSION
BEHIND FRAME
WIDTH
COFFEE SYSTEM
610 mm Model
762 mm Trim
52
|
English
W
597 mm
759 mm
464
mm
WOLF COFFEE SYSTEMS
Planning Information
The coffee system can be installed in a standard or flush
inset application. All 762 mm trim options are based on
model ICBEC24/B. The sides of the cabinetry opening must
be adequate to support installation of the mounting slides.
Refer to the illustration below.
Finish the edges of the opening. They may be visible when
the unit is slid forward.
For standard installations, face trim will overlap stiles and
rails. Refer to the chart below.
For flush inset installations, a minimum 3 mm reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
To install a coffee system above a cup warming drawer,
one opening for both units must be specified. To achieve
the minimum reveal between units, place the coffee system
support rails on top of the cup warming drawer, then secure
the rails to the sides of the cabinet. Any material between
the units will increase the horizontal reveal.
ELECTRICAL
Installation must comply with all applicable electrical codes
and be properly grounded (earthed).
Locate the electrical supply as shown in the illustrations
on the following pages. A separate circuit, servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
ELECTRICAL REQUIREMENTS
Electrical Supply
220-240 V AC, 50/60 Hz
Service
10 amp dedicated circuit
Receptacle
grounding-type (earthed)
Power Cord
1.8 m
INSTALLATION REQUIREMENTS
BASE SUPPORT
MIN
Coffee System
45 kg
TRIM OVERLAP
Top
Bottom
Sides
610 mm MODEL
762 mm TRIM
5 mm
0 mm
18 mm
5 mm
0 mm
98 mm
356
mm
254
mm
19 mm
TYPICAL
Side support.
wolfappliance.com
|
53
WOLF COFFEE SYSTEMS
Coffee System
STANDARD INSTALLATION
548 mm
OPENING
DEPTH
SLIDE
SUPPORT
TOP VIEW
449 mm
SLIDE
SUPPORT
E
OPENING
HEIGHT
W
OPENING WIDTH
SIDE VIEW
FRONT VIEW
NOTE: 610 mm model and model with 762 mm trim require the same opening dimensions.
Dashed line represents profile of unit.
OPENING WIDTH
COFFEE SYSTEM
610 mm Model
762 mm Trim
54
|
English
W
562 mm
562 mm
WOLF COFFEE SYSTEMS
Coffee System
FLUSH INSET INSTALLATION
584 mm
SLIDE
SUPPORT
FLUSH
INSET
DEPTH
25 mm
FINISHED
CLEATS*
TOP VIEW
8 mm
460 mm
SLIDE
SUPPORT
A
FLUSH INSET
HEIGHT**
E
3 mm
W
FLUSH INSET WIDTH**
SIDE VIEW
FRONT VIEW
*Will be visible and should be finished to match cabinetry.
**Dimension provides minimum reveals.
Dashed line represents profile of unit.
FLUSH INSET WIDTH
COFFEE SYSTEM
610 mm Model
762 mm Trim
W
A
603 mm
765 mm
21 mm
102 mm
wolfappliance.com
|
55
WOLF CUP WARMING DRAWER
Cup Warming Drawers
Wolf cup warming drawers preheat cups so hot beverages
stay hot longer. The temperature is adjustable. Two model
options match the look of Wolf stainless and black coffee
systems. Cup warming drawers can be installed in a standard or flush inset application.
DIMENSIONS
140
mm
597 mm
22
mm
CUP WARMING DRAWERS
ICBCW24/S
Stainless
ICBCW24/B
Black
DRAWER
FULL EXTENSION
56
|
English
483
mm
533 mm
BEHIND FRAME
WOLF CUP WARMING DRAWER
Planning Information
The cup warming drawer can be installed in a standard or
flush inset application. Finish the edges of the opening.
They may be visible when the drawer is open.
For standard installations, face trim will overlap stiles and
rails. Refer to the chart below.
For flush inset installations, a minimum 3 mm reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
An anti-tip block must be installed to prevent the cup
warming drawer from tipping forward when opened.
Cup Warming Drawer
Installation must comply with all applicable electrical codes
and be properly grounded (earthed).
Locate the electrical supply as shown in the illustrations
on the following pages. A separate circuit, servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
ELECTRICAL REQUIREMENTS
Electrical Supply
Service
INSTALLATION REQUIREMENTS
BASE SUPPORT
ELECTRICAL
MIN
34 kg
220-240 V AC, 50/60 Hz
5 amp dedicated circuit
Receptacle
grounding-type (earthed)
Power Cord
.9 m
TRIM OVERLAP
Top
Bottom
Sides
0 mm
0 mm
18 mm
COMBINATION INSTALLATION
To install a cup warming drawer below a coffee system,
one opening for both units must be specified. To achieve
the minimum reveal between units, place the coffee system
support rails on top of the cup warming drawer, then secure
the rails to the sides of the cabinet. Any material between
the units will increase the horizontal reveal.
Installation of an anti-tip block is not necessary when the
cup warming drawer is installed below a coffee system.
wolfappliance.com
|
57
WOLF CUP WARMING DRAWER
Cup Warming Drawer
STANDARD INSTALLATION
572 mm
OPENING
DEPTH
TOP VIEW
ANTI-TIP BLOCK
140 mm
OPENING HEIGHT
E
562 mm
OPENING WIDTH
SIDE VIEW
NOTE: Dashed line represents profile of unit.
58
|
English
FRONT VIEW
WOLF CUP WARMING DRAWER
Cup Warming Drawer
FLUSH INSET INSTALLATION
597 mm
FLUSH
INSET
DEPTH
25 mm
FINISHED
CLEATS*
TOP VIEW
3 mm
ANTI-TIP BLOCK
146 mm
FLUSH INSET HEIGHT**
21
mm
E
3 mm
603 mm
FLUSH INSET WIDTH**
SIDE VIEW
FRONT VIEW
*Will be visible and should be finished to match cabinetry.
**Dimension provides minimum reveals.
NOTE: Dashed line represents profile of unit.
wolfappliance.com
|
59
WOLF COOKTOP HOODS
Cooktop Ventilation Hoods
The new generation of Wolf cooktop ventilation hoods
feature three new looks—black, stainless and glass.
Brilliant LED lighting illuminates your cooking surface while
powerful multi-speed blowers whisk away smoke and
odors. Dishwasher-safe filters can be removed easily for
cleaning. Wall-mount and island hoods are crafted of
stainless steel.
COOKTOP VENTILATION HOODS
BLACK
ICBVW30B Wall
ICBVW36B Wall
ICBVW45B Wall
ICBVW36S Wall
ICBVI42S Island
ICBVI42B Island
STAINLESS
ICBVW30S Wall
GLASS
ICBVW36G Wall
60
|
English
ICBVW45G Wall
ICBVI45G Island
WOLF COOKTOP HOODS
Cooktop Ventilation Hoods
WALL HOODS—BLACK
298 mm
260 mm
740 mm
540
mm
TO
997 mm*
57 mm
W
489 mm
WIDTH
*1248 mm to 1505 mm with accessory flue extension.
WIDTH
WALL HOOD
W
ICBVW30B
ICBVW36B
ICBVW45B
762 mm
914 mm
1143 mm
ISLAND HOOD—BLACK
349 mm
286 mm
591 mm
TO
813 mm*
600
mm
57 mm
1067 mm
673 mm
*1175 mm to 1397 mm with accessory flue extension.
wolfappliance.com
|
61
WOLF COOKTOP HOODS
Cooktop Ventilation Hoods
WALL HOODS—STAINLESS
298 mm
260 mm
740 mm
540
mm
TO
997 mm*
152
mm
W
559 mm
WIDTH
*1248 mm to 1505 mm with accessory flue extension.
WIDTH
WALL HOOD
W
ICBVW30S
ICBVW36S
762 mm
914 mm
ISLAND HOOD—STAINLESS
349 mm
286 mm
591 mm
TO
813 mm*
600
mm
152
mm
1067 mm
*1175 mm to 1397 mm with accessory flue extension.
62
|
English
673 mm
WOLF COOKTOP HOODS
Cooktop Ventilation Hoods
WALL HOODS—GLASS
298 mm
260 mm
740 mm
TO
997 mm*
540
mm
57 mm
W
489 mm
WIDTH
*1248 mm to 1505 mm with accessory flue extension.
WIDTH
WALL HOOD
W
ICBVW36G
ICBVW45G
914 mm
1143 mm
ISLAND HOOD—GLASS
349 mm
286 mm
591 mm
TO
813 mm*
600
mm
57 mm
1143 mm
673 mm
*1175 mm to 1397 mm with accessory flue extension.
wolfappliance.com
|
63
WOLF COOKTOP HOODS
Planning Information
Wolf cooktop ventilation hoods are recommended for use
with Wolf induction, electric and gas cooktops and integrated modules. For ranges and rangetops, a Wolf pro ventilation hood is recommended.
These hoods have a telescopic chimney flue. A flue extension is available through an authorized Wolf dealer.
Installation of the cooktop hood should be 762 mm to
914 mm from the bottom of the hood to the countertop.
Wall and island hoods require an internal or remote blower
assembly, avail­able through an authorized Wolf dealer. Refer
to ventilation recommendations on page 70. Cooktop hoods
have a vertical discharge with 152 mm round duct.
ELECTRICAL
Installation must comply with all applicable electrical codes
and be properly grounded (earthed).
For wall hoods, locate the electrical supply within the
shaded area shown in the illustration below. For island
hoods, locate the electrical supply on the ceiling inside the
top of the hood.
ELECTRICAL REQUIREMENTS
Electrical Supply
220-240V, 50 Hz
220V, 60 Hz
Service
10 amp dedicated circuit
Consult a qualified HVAC professional for specific installation and ducting applications.
E
457
mm
762 mm TO 914 mm BOTTOM EDGE TO COUNTERTOP
Electrical location—all wall hoods.
64
|
English
WOLF DOWNDRAFT SYSTEMS
Downdraft Ventilation
Constructed of heavy duty stainless steel, the Wolf downdraft rises from the countertop to whisk away odor and
smoke into stainless steel, mesh filters and can be lowered beneath the countertop when not in use. Downdrafts
integrate perfectly with transitional induction cooktops, gas
cooktops and some integrated modules, they can also be
installed with certain sealed burner rangetops.
DOWNDRAFTS
ICBDD30
ICBDD36
ICBDD45
wolfappliance.com
|
65
WOLF DOWNDRAFT SYSTEMS
Downdraft
DIMENSIONS
51 mm
W
DOWNDRAFT WIDTH
172
mm
356
mm
60 mm
330
mm
381
mm
730
mm
254
mm
330
mm
A
64 mm
CHIMNEY WIDTH
NOTE: Shown with front mounted internal blower with 152 mm round discharge,
dashed line represents rear mount.
WIDTH
DOWNDRAFT
ICBDD30
ICBDD36
ICBDD45
66
|
English
W
A
762 mm
914 mm
1143 mm
673 mm
826 mm
978 mm
WOLF DOWNDRAFT SYSTEMS
Planning Information
Wolf downdrafts can be installed with most Wolf cooktops, but are not compatible with contemporary induction
cooktops and the grill, steamer and fryer modules. Downdrafts can be installed with sealed burner rangetop model
ICBSRT304. An accessory trim kit is necessary for this
installation. Contact an authorized Wolf dealer for details.
The remote-mounted control module must be located within
2.7 m of the downdraft assembly and a minimum 76 mm
from the edge of the cooktop cut-out.
Internal and remote blowers are available through an authorized Wolf dealer. Refer to ventilation recommendations on
page 70.
Internal blowers include a 152 mm round discharge and can
be front or rear mounted. It can be discharged in any direction by rotating the blower box. Remote blowers include a
254 mm discharge and can be discharged from the front or
rear.
ELECTRICAL
Installation must comply with all applicable electrical codes
and be properly grounded (earthed).
Locate the electrical supply as shown in the illustrations
on the following pages. A separate circuit, servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
Certain installations may require that the electrical supply
be placed in an adjacent cabinet.
ELECTRICAL REQUIREMENTS
Electrical Supply
220-240 V AC, 50 Hz
220 V AC, 60 Hz
Service
10 amp dedicated circuit
Receptacle
grounding-type (earthed)
Power Cord
.8 m
Consult a qualified HVAC professional for specific installation and ducting applications.
wolfappliance.com
|
67
WOLF DOWNDRAFT SYSTEMS
Downdraft
INSTALLATION WITH COOKTOP
W
DOWNDRAFT
CUT-OUT WIDTH
68 mm
E
210 mm*
COOKTOP CUT-OUT
TOP VIEW
210
mm*
540
mm
540
mm
594
mm
E
SIDE VIEW
FRONT VIEW
*152 mm back from countertop cut-out when internal blower is rear mounted.
NOTE: Internal blower 152 mm round, side, rear or bottom discharge. Remote blower 254 mm round, rear discharge.
Centerline indicates center of downdraft cut-out.
CUT-OUT WIDTH
DOWNDRAFT
ICBDD30
ICBDD36
ICBDD45
68
|
English
W
699 mm
851 mm
1003 mm
WOLF DOWNDRAFT SYSTEMS
Downdraft
INSTALLATION WITH SEALED BURNER RANGETOP
W
DOWNDRAFT
CUT-OUT WIDTH
68 mm
E
210 mm*
RANGETOP OPENING
TOP VIEW
483 mm
PLATFORM DEPTH
540
mm
540
mm
594
mm
210
mm*
E
SIDE VIEW
FRONT VIEW
*152 mm back from countertop cut-out when internal blower is rear mounted.
NOTE: Internal blower 152 mm round, side, rear or bottom discharge. Remote blower 254 mm round, rear discharge.
Centerline indicates center of downdraft cut-out.
CUT-OUT WIDTH
DOWNDRAFT
ICBDD30
ICBDD36
W
699 mm
851 mm
wolfappliance.com
|
69
WOLF VENTILATION RECOMMENDATIONS
Wolf Ventilation Blower Options
BLOWER
CMH
INTERNAL
900
REMOTE
1521
1528
2028
2535
•
•
•
•
•
•
•
COOKTOP HOOD
ICBVW30B ICBVW36B ICBVW45B ICBVI42B
ICBVW30S ICBVW36S ICBVI42S
ICBVW36G ICBVW45G ICBVI45G
•
•
•
DOWNDRAFT
ICBDD30 ICBDD36 ICBDD45
•
Wolf, Wolf & Design, Wolf Gourmet, W & Design and the color red as applied to knobs are registered trademarks and service marks of Wolf Appliance, Inc. Sub-Zero, Sub-Zero &
Design, Dual Refrigeration, Constant Care, The Living Kitchen, Great American Kitchens The Fine Art of Kitchen Design, and Ingredients are registered trademarks and service marks
of Sub-Zero, Inc. All other trademarks or registered trademarks are property of their respective owners in the United States and other countries.
70
|
English
Wolf Products Limited Warranty
INTERNATIONAL PRODUCTS
FOR RESIDENTIAL USE ONLY
FULL TWO YEAR WARRANTY
For two years from the date of original installation, your Wolf Appliance product warranty covers all parts
and labor to repair or replace, under normal residential use, any part of the product that proves to be
defective in materials or workmanship. All service provided by Wolf Appliance under the above warranty
must be performed by Wolf factory certified service, unless otherwise specified by Wolf Appliance, Inc.
Service will be provided during normal business hours.
LIMITED THIRD THROUGH FIFTH YEAR WARRANTY
For five years from the date of original installation, Wolf Appliance will repair or replace the following parts
that prove to be defective in materials or workmanship: gas burners (excluding appearance), electric
heating elements, blower motors (ventilation hoods), electronic control boards, magnetron tubes and
induction generators. The part(s) will be repaired or replaced, free of charge, with the owner paying for
all other costs including labor. All service provided by Wolf Appliance under the above warranty must be
performed by Wolf factory certified service, unless otherwise specified by Wolf Appliance, Inc. Service will
be provided during normal business hours.
wolfappliance.com
|
71
WOLF APPLIANCE, INC.
PO BOX 44848
MADISON, WI 53744 USA
WOLFAPPLIANCE.COM
IWNGDG
8 / 2015
Download PDF
Similar pages