Special Description Application Your benefits - ACS-Control

Fill level measurement
Sonicont® USG2 & USF2
separate version
Ultrasonic level measurement for non-contact
continuous level measurement in liquids
Description
The series Sonicont USD is noncontact level measurement devices
based on ultrasound. The devices are
suitable for all kinds of liquids and
coarse-grained solids (grain size from
4 mm) in silos, tanks, on conveyor
belt, heap and band transfer stations.
The ranges go from 0.25m up to 15m
in liquids and up to 7m in solids.
One can select between devices with
analogue output in 2-wire technology
(4-20mA) and versions with separate
power supply (4-wire). The units are
supplied with HART protocoll.
USD-050
As an option, Profibus PA and
FOUNDATION fieldbus outputs are
available.
The settings can be performed by a
simple menu-guided local operation
with plain text display, or a PC via a
free operating program.
USD-080
Due to interference echo mapping,
it is possible to hide unwanted
reflections - caused by fixtures such
as agitators, struts and flanges
- and sowith to ensure a reliable
measurement.
USD-100
USD-150
Application
Special
• Continuous non-contact fill level measurement of liquids,
pastes, slurries and powdery, lumpy solids
• Flow measurement in open channels and weirs
• Fill level measurement in hazardous areas
Your benefits
• Easy to use: documentation and diagnostics via
free operating program
• Setup possible without filling the container
• 2-wire technology, reduced wiring
• Simple menu-driven keypad control with plain text display
• Remote adjustment and indication possible via FHX40
solid materials
liquids
non-contact
measurement
certification
HART
P
B
R
U
O
F
I
S
4...20mA
2-wire
Profibus
Order code . . . . . . page |06-07|
FHX40
ACS-CONTROL-SYSTEM GmbH | Lauterbachstr. 57| 84307 Eggenfelden | +49 (0)8721 / 9668-0 | www.acs-controlsystem.de | info@acs-controlsystem.de
|1|
Technical data
Series Sonicont® USD
Technical data
Block distance:
USD 050: 0,25m; USN 080: 3,5m; USN 100: 0,4m; USN 150: 0,6m
Resolution:
USD 050/USN 080: 1mm; USN 100/USN 150: 2mm
Frequency:
USD 050: ca. 70 kHz; USN 080: ca. 50 kHz
USN 100: ca. 42 kHz; USN 150: ca. 35 kHz
Pulse Rate:
depending on sensor type (max. 0,5 Hz at 2-wire/max 2 Hz at 4-wire)
3dB Radiation angle:
USD 050/USN 080/USN 100: 11°; USN 150: 6°
Output signal:
4...20 mA with HART-protocoll (Standard), PROFIBUS PA, FOUNDATION FIELDBUS
(Option)
Load:
for HART-communication minimal 250 Ohm
Mounting position:
Perpendicular to the product surface
Supply voltage:
Two wire: 14-36V DC, Four wire: 10,5-32V DC, 90-253 V AC 50/60 Hz
CE-Approval:
Sonicont meets the requirements of the relevant EC directives.
Ex-approvals:
ATEX II 1/2 G Ex ia II C T6; ATEX II 1/2 G Ex d (ia) IIC T6;
ATEX II 1/2 D, Alu Blinddeckel; ATEX II 1/3 D
Measurement range
Liquids:
USD 050: 5m; USN 080: 8m; USN 100: 10m; USN 150: 15m
Solids:
USD 050: 2m; USN 080: 3,5m; USN 100: 5m; USN 150: 7m
Measuring accuracy
Messabweichung:
USD 050/USN 080:
± 2 mm or 0,2 % des eingestellten Messbereichs (größerer Wert)
USD 050/USN 080:
± 4 mm or 0,2 % des eingestellten Messbereichs (größerer Wert)
Material
Process connection:
USD 050: G 1½“ ISO 288; USN 080: G 2“ ISO 288;
USD 100: DN80/100 or mounting bracket;
USD 150: D N100 Überwurfflansch or mounting bracket
Medium contact material
USD 050/USD080:
screw-in thread and sensor: PVDF;
between screw-in thread and internal sensor: EPDM-gasket
Medium contact material USD 100:
Sensor: PVDF;
between sensor and flange: VITON® or EPDM;
flange: PP
Medium contact material USD 150:
Swing case UP, gasket, EPDM;
Membrane 1.4571/316Ti PVDF or 316L
Environmental conditions
| 2 |
Ambient temperature:
USD 050/USN 080/USD 050/USN 080: -40...+80°C
Process temperature:
USD 050/USN 080/USD 050/USN 080: -40...+80°C
Process pressure: Pabs:
USD 050/USN 080: 0,7...3 bar
USD 050/USN 080: 0,7...2,5 bar
Protection:
IP68, at open casing cover IP20
ACS-CONTROL-SYSTEM GmbH | Lauterbachstr. 57| 84307 Eggenfelden | +49 (0)8721 / 9668-0 | www.acs-controlsystem.de | info@acs-controlsystem.de
Dimension drawings
Series:
Sonicont® USD
Series Sonicont® USD
ACS-CONTROL-SYSTEM GmbH | Lauterbachstr. 57| 84307 Eggenfelden | +49 (0)8721 / 9668-0 | www.acs-controlsystem.de | info@acs-controlsystem.de
|3|
Order code
Compact transmitter for non-contact level
measurement of fluids (5m), pastes and coarse
bulk materials (2m)
Connection
Profibus PA / FF
USD 050 - Sonicont® USD 050
Compact transmitter for non-contact level measurement with integrated temperature sensor
For automatic correction of the temperature dependent sound velocity
Application:
in liquids and bulk materials
Measure Range:in liquids 5m and in bulk materials 2m
Temperature: Process temperature –40...+80°C
Materials:
Thread and sensor: PVDF
Process conn..: G1½“ thread
Certificates:
ATEX II 1/2 G Ex ia II C T6; ATEX II 1/2 G Ex d (ia) IIC T6; ATEX II 1/2 D; ATEX II 1/3 D
S
N
E1
E4
E2
E5
Two wire (Hart)
Certificates
Non-hazardous area
CSA General Purpose
ATEX II 1/2 G Ex ia II C T6
ATEX II 1/2 G Ex d (ia) IIC T6
ATEX II 1/2 D, aluminium blind cover
ATEX II 1/3 D
Process connection
G
G1½“ thread ISO 228, PVDF
A
B
C
D
E
Power supply, communication
2-wire,
2-wire,
2-wire,
4-wire,
4-wire,
0
D
A
Display, operation
Without display
With display VU331, 4-line plain text display
menu-guided onsite operation
Prepared for FHX40, remote display mounting (Equipment)
0
C
Four wire (Hart)
4...20 mA - loop/HART
PROFIBUS-PA
Foundation Fieldbus
90...250VAC; 4...20 mA HART
10,5...32 VDC; 4...20 mA HART
Housing
Aluminium F12-housing coated IP68
T12 Alu, coated IP68, NEMA6P, separate connection compartment
2
4
5
Screw connection, insertion
M20x1,5 screw connection
Thread NPT ½
M12 PROFIBUS-PA plug
S
Supplementary equipment
Standard
Order code
USD 050
| 4 |
G
0
S
ACS-CONTROL-SYSTEM GmbH | Lauterbachstr. 57| 84307 Eggenfelden | +49 (0)8721 / 9668-0 | www.acs-controlsystem.de | info@acs-controlsystem.de
Series: Sonicont®
Order code
Compact transmitter for non-contact level
measurement of fluids (8m), pastes and coarse bulk
materials (3,5m)
Connection
Profibus PA / FF
USD 080 - Sonicont® 080
Compact transmitter for non-contact level measurement with integrated temperature sensor
For automatic correction of the temperature dependent sound velocity
Application:
in liquids and bulk materials
Measure Range:in liquids 8m and in bulk materials 3,5m
Temperature: Process temperature –40...+80°C
Materials:
Thread and sensor: PVDF
Process conn..: G2“ thread
Certificates:
ATEX II 1/2 G Ex ia II C T6; ATEX II 1/2 G Ex d (ia) IIC T6; ATEX II 1/2 D; ATEX II 1/3 D
S
N
E1
E4
E2
E5
Two wire (Hart)
Certificates
Non-hazardous area
CSA General Purpose
ATEX II 1/2 G Ex ia II C T6
ATEX II 1/2 G Ex d (ia) IIC T6
ATEX II 1/2 D, aluminium blind cover
ATEX II 1/3 D
Process connection
G
G2“ thread ISO 228, PVDF
A
B
C
D
E
Power supply, communication
2-wire,
2-wire,
2-wire,
4-wire,
4-wire,
0
D
A
Four wire (Hart)
USD 050 / 080
4...20 mA - loop/HART
PROFIBUS-PA
Foundation Fieldbus
90...250 V AC; 4...20 mA HART
10,5...32 V DC; 4...20 mA HART
Display, operation
Without display
With display VU331, 4-line plain text display
menu-guided onsite operation
Prepared for FHX40, remote display mounting (Equipment)
0
C
Housing
Aluminium F12-housing coated IP68
T12 Alu, coated IP68, NEMA6P, separate connection compartment
2
5
Screw connection, insertion
M20x1,5 screw connection
M12 PROFIBUS-PA plug
S
Supplementary equipment
Standard
Order code
USD 080
G
0
S
ACS-CONTROL-SYSTEM GmbH | Lauterbachstr. 57| 84307 Eggenfelden | +49 (0)8721 / 9668-0 | www.acs-controlsystem.de | info@acs-controlsystem.de
|5|
Order code
Compact transmitter for non-contact level
measurement of fluids (10m), pastes and coarse
bulk materials (5m)
Connection
Profibus PA / FF
USD 100 - Sonicont® USD 100
Compact transmitter for non-contact level measurement with integrated temperature sensor
For automatic correction of the temperature dependent sound velocity
Application:
in liquids and bulk materials
Measure Range:in liquids 10m and in bulk materials 5m
Temperature: Process temperature –40...+80°C
Materials:
sensor: PVDF, gasket between sensor an d flange: Viton® or EPDM
Process conn..: DN80/100 or mounting bracket
Certificates:
ATEX II 1/2 G Ex ia II C T6; ATEX II 1/2 G Ex d (ia) IIC T6; ATEX II 1/2 D; ATEX II 1/3 D
S
N
E1
E4
E2
E5
Two wire (Hart)
Certificates
Non-hazardous area
CSA General Purpose
ATEX II 1/2 G Ex ia II C T6
ATEX II 1/2 G Ex d (ia) IIC T6
ATEX II 1/2 D, aluminium blind cover
ATEX II 1/3 D
Process connection
M
P
Mounting bracket FAU20
DN80/ANSI 3“/JIS80A, PP universal flange max. 3 bar abs;
Screw-hole circle: PN16/150LBS/10K
A
B
C
D
E
Power supply, communication
2-wire,
2-wire,
2-wire,
4-wire,
4-wire,
0
D
A
Four wire (Hart)
4...20 mA - loop/HART
PROFIBUS-PA
Foundation Fieldbus
90...250 V AC; 4...20 mA HART
10,5...32 V DC; 4...20 mA HART
Display, operation
Without display
With display VU331, 4-line plain text display menu-guided onsite operation
Prepared for FHX40, remote display mounting (Equipment)
0
C
Housing
Aluminium F12-housing coated IP68
T12 Alu, coated IP68, NEMA6P, separate connection compartment
2
4
5
Screw connection, insertion
M20x1,5 screw connection
Thread NPT ½
M12 PROFIBUS-PA plug
2
3
Gasket sensor / flange
Viton® flat gasket
EPDM flat gasket
S
Supplementary equipment
Standard
Order code
USD 100
| 6 |
0
S
ACS-CONTROL-SYSTEM GmbH | Lauterbachstr. 57| 84307 Eggenfelden | +49 (0)8721 / 9668-0 | www.acs-controlsystem.de | info@acs-controlsystem.de
Series: Sonicont®
Order code
USD 100 / 150
Compact transmitter for non-contact level
measurement of fluids (15m), pastes and coarse
bulk materials (7m)
Connection
Profibus PA / FF
USD 150 - Sonicont® SD 150
Compact transmitter for non-contact level measurement with integrated temperature sensor
For automatic correction of the temperature dependent sound velocity
Application:
in liquids and bulk materials
Measure Range:in liquids 15m and in bulk materials 7m
Temperature: Process temperature –40...+80°C
Materials:
Thread and sensor: PVDF
Process conn..: DN100 flange or mounting bracket
Certificates:
ATEX II 1/2 D; ATEX II 1/3 D
S
N
E2
E5
Two wire (Hart)
Certificates
Non-hazardous area
CSA General Purpose
ATEX II 1/2 D, aluminium blind cover
ATEX II 1/3 D
Process connection
K
M
P
wthout flange or mounting bracket
customer-supplied mounting
With mounting bracket FAU20
DN100 flange / ANSI 4“/JIS 16K100, PP>uhiversal slip-on flange
B
C
D
E
Power supply, communication
2-wire,
2-wire,
4-wire,
4-wire,
0
D
A
Four wire (Hart)
PROFIBUS-PA
Foundation Fieldbus
90...250 V AC; 4...20 mA HART
10,5...32 V DC; 4...20 mA HART
Display, operation
Without display
With display VU331, 4-line plain text display
menu-guided onsite operation
Prepared for FHX40, remote display mounting (Equipment)
0
Housing
Aluminium F12-housing coated IP68
2
4
5
Screw connection, insertion
M20x1,5 screw connection
Thread NPT ½
M12 PROFIBUS-PA plug
S
Supplementary equipment
Standard
Order code
USD 150
0
S
ACS-CONTROL-SYSTEM GmbH | Lauterbachstr. 57| 84307 Eggenfelden | +49 (0)8721 / 9668-0 | www.acs-controlsystem.de | info@acs-controlsystem.de
|7|
Equipment
Series Sonicont® USD
Remote display and keypad control for Sonicont®
Remote display and keypad control for Sonicont® and Radarcont
Aluminum field housing IP65, 4-line LCD display
Menu-guided plaintext operation, easy adjustment,
Operator selectable language, envelope curve display on site
A
1
N
Certifications
Variation for non-Ex-area
ATEX II 2 G Ex ia IIC T6
CSA General Purpose
1
Order code
Cable length
20 m cable (> HART)
A
B
FHX 40
Additional equipment
Standard
Mounting bracket tube 1“/ 2“
1
Communication box
G
P
S
V
Order code
Certifications
ATEX II (1) GD (EEx ia) IIC
FM, AIS, CI.I, II, III Group A-G
CSA, CI.I, II, III Group A-G
Special version
1
9
Power supply
Supply via USB interface
Special version
FXA 195
Equipment
Order information 52013874 52014131 52014137 52014132 52014134 52014136 52014138 919792-0000
919792-0001
942669-0000
942669-0001
543199-0001
942666-0000
919791-0000
919791-0002
919791-0001
919791-0003
Model
Mounting bracket FHX40 1“/2“ tube
Outrigger 500 mm, ST, 1,5“-sensor
Outrigger 1000 mm, ST, 2“-sensor
Outrigger 500 mm, VA, 1,5“-sensor
Outrigger 1000 mm, VA, 1,5“-sensor
Outrigger 500 mm, VA, 2“-sensor
Outrigger 1000 mm, VA, 2“-sensor
Wall bracket for outrigger, ST
Wall bracket for outrigger, VA
Angle montage- 250x400x120 + G1½“ A2
Angle montage- 250x400x120 + G2“ A2
Protection cover for housing F12 VA
Mounting bracket FAU20
Stand 700 mm, ST
Stand 1400 mm, ST
Stand 700 mm, VA
Stand 1400 mm, VA
Flange
Process connection
12 DN50 PN16 steel Flange EN1092-1
14 DN80 PN16 steel Flange EN1092-1
15 DN100 PN16 steel Flange EN1092-1
3
4
Sensor connection
G1½“ ISO 228
G2“ ISO 228
FAX 50
Stand 01/2017
Order code
Download PDF
Similar pages