33-00361-01 - T6 Pro Hydronic Programmable

T6 Pro Hydronic Programmable Thermostat
SUBMITTAL SHEET
Job Name
Engineer
Mechanical Contractor
Contractor’s P.O. No.
Representative
Notes
Model(s)
TH6100AF2004
Approval
Service
Tag No.
APPLICATION
Adjustable min on time to prevent short cycling.
Qty.
Adjustable CPH (cycle per hour)
Model TH6100AF2004:
Continuous backlight brightness setting (C-wire only)
Single stage hot water heat only systems.
AQ12C20 wired floor sensor (included in package).
Dimensions Lead Length: 180 in. (4570 mm.) 10 kohm NTC thermistor at 25 C
(77 F) +/- 0.5F (+/-0.3C)
C7189U1005 wired indoor air sensor. Optional. Cannot be used if floor sensor is
used.
Power Requirements:
AA alkaline battery 2pcs. And/or
C-wire input: 18-30VAC; 50Hz-60Hz
Typical Power Consumption:
Backlight On: 1.0VA
A mode: Controls and displays the ambient air temperature only.
Selectable Ranges Stops:
F mode: Controls and displays the floor temperature only using an external floor
temperature sensor. This control mode is suitable for areas such as bathrooms
where floor temperature could be scheduled to be warm only during occupied,
morning and evening periods.
Max Heat:
•
•
Notes
A/AF mode: 40 °F to 90 °F (default 90 °F);
4.5 °C to 32.0 °C (default 32.0 °C)
Floor temperature is indicated by “FLR” above the actual floor temperature.
Actual ambient air temperature could also be displayed in the Thermostat
MENU/TEMP.
F mode: 40 °F to 99 °F (default 85 °F);
4.5 °C to 38.0 °C (default 29.5 °C)
Min Heat:
AF mode: Controls and displays the ambient air temperature as well as maintains
the floor temperature within desired floor temperature limits using an external floor
temperature sensor. Setting the minimum and maximum floor temperature limits is
a way to enhance comfort and to protect the floor covering at the same time.
A/AF mode: 40 °F to 90 °F (default 50 °F);
4.5 °C to 32.0 °C (default 10 °C)
SPECIFICATIONS
Min Floor Temp Limit: 40 °F to 89 °F (72 °F);
4.5 °C to 31.5 °C (22.2 °C)
Terminal Designations: R, RC, C, W, S, and S.
Max Floor Temp Limit: 50 °F to 99 °F (85 °F);
10 °C to 38 °C (29.5 °C)
Electrical Ratings:
F mode: 40 °F to 99 °F (default 50 °F);
4.5 °C to 38.0 °C (default 10 °C)
Voltage
(50/60Hz)
Running Current
Freeze Protection Temperature:
W Heating
18-30 Vac
0.02-1.0 A
A Mode: 40 °F to 50 °F (40 °F); 4.5 °C to 10.0 °C (4.5 °C)
(Powerpile)
750 mV DC
100 mA DC
Terminal
A/AF Mode: 40 °F (4.5 °C) to Min. Floor Temp. Limit
F Mode: 40 °F (4.5 °C) to Min. Heat Temp. Setpoint
Programming Options: 7-day, 5-1-1, 5-2, non- programmable
Heat Indication: Displays “Heat On” when the thermostat turns the heating on.
Operating Ambient Temperature:
37 °F to 102 °F (2.8 °C to 38.9 °C)
Temperature Sensor Accuracy:
± 1.5 °F at 70 °F (0.85 °C at 21.0 °C)
Shipping Temperature: -20 °F to 120 °F (-28.9 °C to 48.9 °C)
Clock Accuracy: ± 1 minute every month (30 days) at 77°F.
± 2 minutes per month over the operating ambient temperature range.
Operating Relative Humidity: 5% to 90% (non-condensing)
DST Enabled
Physical Dimensions: 4-1/16” H x 4-1/16” W x 1-5/32” D
103.5 mm H x 103.5 mm W x 29 mm D
Color: White
5 Year Warranty
Display Size: 5.44 sq. in.
Mounting Means: Thermostat packaged with a UWP mounting system that mounts
directly on the wall in the living space using mounting screws and anchors provided.
Use the cover plate (also included with thermostat) and its mounting bracket to
mount the thermostat onto a vertical 2 x 4 in. junction box.
Vacation mode settings and floor economy mode for energy savings.
Home and Building Technologies
In the U.S.:
Honeywell
715 Peachtree Street NE
Atlanta, GA 30308
customer.honeywell.com
® U.S. Registered Trademark
© 2017 Honeywell International Inc.
33-00361—01 M.S. 09-17
Printed in United States