120VLPU INST - ConTech Lighting

INSTALLATION INSTRUCTIONS
For ConTech Lighting 120V LED Dimmable 3 Color Level Under Cabinet Light:
LPU2121, LPU2181, LPU2241, LPU2321 SERIES
Components
End-to-End Connector
1 X LED 3 Color Level Light
1 X 6' Power Cord
Jumper Connector
2 x Screws
Romex Connection Kit
1 x Installation Instructions
INSTALLATION PROCEDURES
Please read these instructions before commencing installation and retain for future reference.
Important Safety Information
Please read these instructions carefully before attempting to install this product. It is advisable to keep these instructions in a safe place for further
reference.
WARNING: These products may represent a possible shock or fire hazard if improperly installed or attached in any way. Products should be installed
in accordance with these instructions, current electrical codes and/or the current National Electric Code (NEC).
WARNING: To avoid electrical shock, disconnect or disable power at the source prior to installation or maintenance.
WARNING: To avoid electrical shock, and to assure proper operation, this fixture must be adequately grounded.
WARNING: To avoid electrical shock, use only with 120V AC plug-in power supply or with 120V AC hardwire power supply. Factory warranty will be
void if used with a non-recommended power supply, transformer, or driver.
WARNING: To avoid electrical shock, and to assure proper operation, this fixture must be adequately grounded.
WARNING: 12-inch minimum spacing distance from luminaire required for all objects located under fixture.
WARNING: Linkable total wattage is 200 Watts.
Safety Instructions
1. The ConTech Lighting Undercabinet Light is listed cETLus and intended for indoor use in dry locations only. Do not use in the vicinity of standing
water or liquids. Do not submerge in water or liquids.
2. Do not use if there is any damage to the unit or to the power cord’s insulation. Inspect periodically.
3. Do not route cords or units through walls, doors, windows or any similar part of a building structure.
4. Do not secure unit or its power cord with staples, nails, or any other sharp objects that may damage the cords.
5. Please read and understand these instructions before beginning installation.
Maintenance & Care
1. Ensure that the power is disconnected prior to cleaning.
2. To keep the finish of this product, wipe over with soft cloth periodically.
3. Do not use harsh chemical solvents, it may dis-colour or damage the finish.
Preparation for Installation
1. Disconnect electrical power before installing or servicing any part of this fixture.
2. Place fixture on a clean flat surface.
3. Determine input power connection method (Plug-In, Hardwire).
Continued on Page 2
All specifications subject to change without notice. For ConTech’s limited product warranty, go to www.contechlighting.com. For a printed copy of the warranty, call 1-847-559-5500.
1-847-559-5500
www.contechlighting.com
This document can be recycled.
120VLPU INST
INSTALLATION INSTRUCTIONS
For ConTech Lighting 120V LED Dimmable 3 Color Level Under Cabinet Light:
LPU2121, LPU2181, LPU2241, LPU2321 SERIES
Plug-In Instructions
2
1
Fix the fixture to the unit using 2 fixing screws
Connect the multiple fixtures by snapping the End to End Connetcor or Jumper Connector .
3
4
Finally, plug-in the power cord to 120V AC power outlet.
By flipping the switch (a) select between one of
the 3 modes (Lo, Off, Hi ).
Switch (b) is used to change the color
temperature of light delivered 2700K, 3000K &
4000K CCT respectively.
Hardwire Installation
1
2
Remove the kock- out by hammering
3
Disengage adapter plate by loosening screw.
4
5
Insert romex connector into the housing open hole
on the adapter plate. Secure it with the nut.
6
Pull 3 wires out of the fixture to allow connection to
the branch circuit.
Connect the Green ground input supply wire to
the fixture Green ground wire.
Inserting wires into the open hole in the push - in
wire connector
Connect the White input supply wire to the fixture
White wire.
Feed wires back into fixture, reattach adapter plate
tighten screw, and attach the fixture to the base of
the cabinet, with screws
Connect the Black input supply wire to the fixture
Black wire.
**Do not mix wires or change polarity.
All specifications subject to change without notice. For ConTech’s limited product warranty, go to www.contechlighting.com. For a printed copy of the warranty, call 1-847-559-5500.
1-847-559-5500
www.contechlighting.com
This document can be recycled.
120VLPU INST
INSTALLATION INSTRUCTIONS
For ConTech Lighting 277V Dimmable 3 Color Level Under Cabinet Light:
LPU2122, LPU2182, LPU2242, LPU2322 SERIES
Components
End-to-End Connector
1 X LED 3 Color Level Light
1 x 6' Hardwire Power Cord
Jumper Connector
2 x Screws
Romex Connection Kit
1 x Installation Instructions
INSTALLATION PROCEDURES
Please read these instructions before commencing installation and retain for future reference.
Important Safety Information
Please read these instructions carefully before attempting to install this product. It is advisable to keep these instructions in a safe place for further
reference.
WARNING: These products may represent a possible shock or fire hazard if improperly installed or attached in any way. Products should be installed
in accordance with these instructions, current electrical codes and/or the current National Electric Code (NEC).
WARNING: To avoid electrical shock, disconnect or disable power at the source prior to installation or maintenance.
WARNING: To avoid electrical shock, and to assure proper operation, this fixture must be adequately grounded.
WARNING: To avoid electrical shock, use only with 120V AC plug-in power supply or with 120V AC hardwire power supply. Factory warranty will be
void if used with a non-recommended power supply, transformer, or driver.
WARNING: To avoid electrical shock, and to assure proper operation, this fixture must be adequately grounded.
WARNING: 12-inch minimum spacing distance from luminaire required for all objects located under fixture.
WARNING: Linkable total wattage is 200 Watts.
Safety Instructions
1. The ConTech Lighting Undercabinet Light is listed cETLus and intended for indoor use in dry locations only. Do not use in the vicinity of standing
water or liquids. Do not submerge in water or liquids.
2. Do not use if there is any damage to the unit or to the power cord’s insulation. Inspect periodically.
3. Do not route cords or units through walls, doors, windows or any similar part of a building structure.
4. Do not secure unit or its power cord with staples, nails, or any other sharp objects that may damage the cords.
5. Please read and understand these instructions before beginning installation.
Maintenance & Care
1. Ensure that the power is disconnected prior to cleaning.
2. To keep the finish of this product, wipe over with soft cloth periodically.
3. Do not use harsh chemical solvents, it may dis-colour or damage the finish.
Preparation for Installation
1. Disconnect electrical power before installing or servicing any part of this fixture.
2. Place fixture on a clean flat surface.
3. Determine input power connection method (Plug-In, Hardwire).
Continued on Page 2
All specifications subject to change without notice. For ConTech’s limited product warranty, go to www.contechlighting.com. For a printed copy of the warranty, call 1-847-559-5500.
1-847-559-5500
www.contechlighting.com
This document can be recycled.
277VLPU INST
INSTALLATION INSTRUCTIONS
For ConTech Lighting 277V LED Dimmable 3 Color Level Under Cabinet Light:
LPU2122, LPU2182, LPU2242, LPU2322 SERIES
HARDWIRE INSTALLATION
1
2
Remove the kock- out by hammering
3
Disengage adapter plate by loosening screw.
4
5
Insert romex connector into the housing open hole
on the adapter plate. Secure it with the nut.
6
Pull 3 wires out of the fixture to allow connection to
the branch circuit.
Connect the Green ground input supply wire to
the fixture Green ground wire.
Inserting wires into the open hole in the push - in
wire connector
Connect the White input supply wire to the fixture
White wire.
Feed wires back into fixture, reattach adapter plate
tighten screw, and attach the fixture to the base of
the cabinet, with screws
Connect the Black input supply wire to the fixture
Black wire.
**Do not mix wires or change polarity.
8
7
Fix the fixture to the unit using 2 fixing screws
Connect the multiple fixtures by snapping the End to End Connetcor or Jumper Connector .
9
By flipping the switch (a) select between one of
the 3 modes (Low, Off, Hi ).
Switch (b) is used to change the color
temperature of light delivered 2700K, 3000K &
4000K CCT respectively.
All specifications subject to change without notice. For ConTech’s limited product warranty, go to www.contechlighting.com. For a printed copy of the warranty, call 1-847-559-5500.
1-847-559-5500
www.contechlighting.com
This document can be recycled.
277VLPU INST
Download PDF
Similar pages