171226A03-1
SW830-2
Multi-purpose Switch /
Control Panel
INSTALLATION
It is essential to install the unit properly to ensure safe and reliable operation. Please read through all
instructions thoroughly and carefully before installing the unit. The correct mounting and wiring is the
key to the effectiveness of SW830-2 switch. Installers must read and follow installation instructions and
warnings in the manual from original manufacturer. The vehicle operator should verify this system is
fastened to the vehicle securely and is functioning properly. Failure to follow all safety precautions and
instructions may void warranties, cause personal injury and/or vehicle damage, including fire.
Control Panel
MOUNTING
Mount the power module in a location that is not exposed directly to weather elements such as the driver compartment firewall, below the seat, or in
the trunk; and away from any air bag deployment areas. Ensure that all wiring harness connections are made prior to connecting the harness to the
power module.
Assemble the included panel stand and secure it onto a desired smooth surface via suction cup, where it can be easily accessed by the vehicle operator. If no smooth surface is present, use the included adhesive base to assist the mounting; ensure that the surface is cleaned thoroughly before
applying the adhesive base onto the mounting surface. Leave adhesive to set for at least 24hr before mounting the suction cup on to the base. Once
the mounting stand is fitted, secure the control panel tightly onto the stand.
WARNING: Do not interfere with the proper operation of the vehicle airbag deployment system.
WIRING
Use wires that are capable of handling the required current. Route the wires
properly to prevent wear, overheating and interference with air bag deployment.
Ensure that all connections are tight and double check wiring before connecting
to the vehicle battery.
SW1, SW2, SW3, SW4 : +VDC Output Connections,
each connects to one auxiliary device / relay / input up to 0.1 Amps max.
SW5, SW6, SW7 : +VDC Output Connections,
each connects to one auxiliary device / relay / input up to 0.2 Amps max.
CONTROL PANEL / FUNCTION
BLACK …… -GND
GREEN …… SW4
RED ……….. +VDC
BLUE ……... SW5
YELLOW ….. SW1
BROWN ….. SW6
ORANGE ….. SW2
GRAY ……... SW7
PURPLE …... SW3
WHITE …….. LED Display Signal
Signal Display / LED Indicator:
Displays the flash signal or traffic director signal when WHITE input wire is
connected to a compatible lightbar, or directional/warning advisor.
Button B1, B2, B3, B4:
Activates SW1, SW2, SW3 or SW4 Connection respectively; each may be set
as an ON/OFF or a momentary switch.
Button B1~B3 or Button B1~B4 maybe grouped for mutually exclusive control.
Only one of the buttons may be turned ON at a time. While in mutually exclusive
group, Button B2 will active all SW1, SW2 & SW3 connection together.
(Mutually Exclusive Control, see “PROGRAMMING” section for more details)
Button B8:
Activates pre-programmed buttons. (Programmable Combo Button, See
“PROGRAMMING” section for more details)
Press and hold for 3 seconds to turn off all activated buttons, or press and hold
for 5 seconds to turn the unit completely OFF.
While the unit is OFF, press and hold for 3 seconds to turn the unit back ON.
Button B5:
Activates SW5 Connection; may be set as an ON/OFF or a momentary
switch.
This button may be configured to turn Button B7 ON or OFF upon
activation or deactivation. (Button Mapping, see “PROGRAMMING”
section for more details)
This button may be configured to turn Button B6 OFF when deactivated
and turn itself ON when Button B6 is activated. (European Siren
Interlock, see “PROGRAMMING” section for more details)
Button B7:
Activates SW7 Connection; may be set as an ON/OFF or a momentary switch.
This button may be configured to map with Button B5 for it to be turned ON or
OFF by Button B5. (Button Mapping, see “PROGRAMMING” section for more
details)
Button B6:
Activates SW6 Connection; may be set as an ON/OFF or a momentary switch.
This button may be configured to turn Button B5 ON when activated and turn
itself OFF when Button B5 is deactivated. (European Siren Interlock, see
“PROGRAMMING” section for more details)
PROGRAMMING
Programmable Combo Button:
Button B8 may be used to activate pre-programmed buttons from Button B1 to B7.
To set-up pre-programmed buttons:
1. Press and hold B1 and B4 for 3 seconds to enter PROGRAMMING MODE.
Top Left LED Indicator x4 will light to indicate that you are in PROGRAMMING MODE.
2. While in PROGRAMMING MODE, press and hold B8 for 3 seconds to start button binding.
3. While Top Right LED Indicator x4 is blinking, turn ON the desired button(s) to bind with Button B8.
4. Once set, press and hold B8 for 3 seconds to save the selected buttons then press and hold B1 and B4 for 3 seconds to exit PROGRAMMING MODE.
ON/OFF or Momentary Button Setting:
Button B1 to B7 may be set as an ON/OFF or a momentary activation.
1. Press and hold B1 and B4 for 3 seconds to enter PROGRAMMING MODE.
Top Left LED Indicator x4 will light to indicate that you are in PROGRAMMING MODE.
2. While in PROGRAMMING MODE, turn ON or OFF the desired button for the following scenario:
Button B1~B7 Red Backlit
Button Mode
OFF
ON/OFF (default)
ON
Momentary
3. Once set, press and hold B1 and B4 for 3 seconds to exit PROGRAMMING MODE.
Mutually Exclusive Control:
Button B1~B3 or Button B1~B4 may be grouped for mutually exclusive control. Only one of the buttons may be turned ON at a time.
1. Press and hold B1 and B4 for 3 seconds to enter PROGRAMMING MODE.
Top Left LED Indicator x4 will light to indicate that you are in PROGRAMMING MODE.
2. While in PROGRAMMING MODE, press Button B1 or B2 for 3 seconds to turn ON/OFF its green backlit.
Green Backlit
Mutually Exclusive Group
Button B1 ON
Button B1~B3
Button B2 ON
Button B1~B4
Button B1&B2 OFF
Independent Controlled (default)
Application Example
3. Once set, press and hold B1 and B4 for 3 seconds to exit PROGRAMMING MODE.
Note: While in mutually exclusive group, Button B2 will active all SW1, SW2 & SW3 connection together.
When configuring as Mutually Exclusive Group, these buttons must be configured as “ON/OFF switch”.
European Siren Interlock:
The Button B5 and B6 may be configured so that Button B5 turns Button B6 OFF when deactivated and turn itself ON when Button B6 is activated. This
configuration is commonly used for that Button B5 is used as the primary visual warning device and Button B6 is use as a siren activation.
1. Press and hold B1 and B4 for 3 seconds to enter PROGRAMMING MODE.
Top Left LED Indicator x4 will light to indicate that you are in PROGRAMMING MODE.
2. While in PROGRAMMING MODE, press Button B6 for 3 seconds to turn ON/OFF the green backlit.
Button B6 Green Backlit
Mode
OFF
Interlock OFF (default)
ON
Interlock ON
3. Once set, press and hold B1 and B4 for 3 seconds to exit PROGRAMMING MODE.
Application Example
Note: When configuring as Button mapping mode, Button B5 and Button B6 must be configured as “ON/OFF switch”.
Button Mapping:
Button B7 may be set to activate and deactivate by Button B5.
1. Press and hold B1 and B4 for 3 seconds to enter PROGRAMMING MODE.
Top Left LED Indicator x4 will light to indicate that you are in PROGRAMMING MODE.
2. While in PROGRAMMING MODE, press Button B5 for 3 seconds to turn ON/OFF the green backlit.
Button B5 Green Backlit
Mode
OFF
No Button Mapping (default)
ON
Button B7 Mapped with Button B5
3     old B1 and B4 for 3 second to exit PROGRAMMING MODE.
Application Example
Note: When configuring as Button mapping mode, Button B5 and Button B7 must be configured as an “ON/OFF Switch”.
LED Signal Display Mode Change:
The 10-LED Signal Display may display either the Lightbar flash signal or the directional / warning advisor flash signal. To change the display mode:
1. Press and hold B1 and B4 for 3 seconds to enter PROGRAMMING MODE.
Top Left LED Indicator x4 will light to indicate that you are in PROGRAMMING MODE.
2. While in PROGRAMMING MODE, press Button B8 to turn ON/OFF the red backlit.
Button B8 Red Backlit
Mode
OFF
Directional / warning advisor
flash signal (default)
ON
Lightbar flash signal
3. Once set, press and hold B1 and B4 for 3 seconds to exit PROGRAMMING MODE.
Download PDF