TURBOSTEAM
SERIE 2
English
English
USE
Description
Machines equipped with the TURBOSTEAM (STOP STEAM) dispensing
system have the "stop steam dispensing when set temperature is
reached" function, and can rapidly heat and froth milk.
13
Insert steam nozzle (15) into a suitable container, making sure the tip is
completely submerged in the milk. Select the type of milk you desire:
- using the knob (13), clockwise (frothed) or counter-clockwise
(hot).
15
Once the temperature is reached, steam can be stopped automatically
(with T steam stop = 50° ÷ 85°C) or manually (with T steam stop =
0°), as described in the "Steam Dispensing" paragraph.
The turbosteam steam wand has a nozzle with four holes with a
diameter of 1.75 mm. On request, a nozzle with holes with a diameter
of 1 mm is available and is the best solution for beverages that are
less than 350 g.
The nozzle with 1 mm holes can be identified by the groove “S”.
S
n° 4 holes
ø 1,75mm
n° 4 holes
ø 1mm
Standard nozzle
Optional nozzle
How to access programming mode
How to enter the Programming menu: insert the smart card. The
word TECHNICIAN will appear, besides the date and time.
14 January
wednesday
2004
15:15:04
Technician
Move the cursor to the “configuration” line with the “+” (30) and “-”
(31) keys to access the configuration menu.
Press the “PRG” key (29) key to access the configuration menu. The
following message appears on the display:
Þ CONFIGURATION
Water press.
Group temp.
T stop steam
MEASUREMENT UNITS
N° ground
Piston diamet.
SOFTNER REGENER.
1,4 bar
070°C
075°C
030
002
u
+
Use the "+" (30) and "-" (31) keys to position the cursor on the "T stop
steam" line, then press the PRG (29) key.
Change settings using the "+" (30) and "-" (31) keys, then press the
RES (24) key to confirm the data.
Note: When changing data, the cursor "
" becomes " à".
Þ TECHNICAL PROG.
KEY MENU
CONFIGURATION
TESTING
WEIGHTING
Setting options:
u
+
"0" setting:
• manual steam stop
Any number between "55° ÷ 85°":
• automatic steam stop
"OFF" setting:
• steam stop disabled
English
English
Steam dispensing
MODE 1, STEAM AUTOMATIC STOP
A temperature is set at the “T stop steam xxx°C" field using the "+"
and "-" keys, with "xxx" which ranges from a minimum of 50°C and
a maximum of 85°C.
Steam dispensing is controlled by the knob (13).
In particular:
- when the knob is turned to the right, the milk is heated.
- When the knob is turned to the left, the milk is frothed.
Once the knob has been turned (13), it automatically returns to the
"O" position.
T steam:
064°C
MODE 2, STEAM MANUAL STOP
Set the temperature value on item "T stop steam xxx°C" at "000" zero.
Steam dispensing and the choice of milk type are performed as in
MODE 1.
14 January
wednesday
T steam:
2004
15:15:04
050°C
Note: The user controls when steam dispensing is stopped.
When the desired temperature is reached, the user will turn the
automatic steam knob (13) in the same direction used to start the
steam dispensing process.
For the next 3" after steam dispensing has stopped, the display
shows the milk temperature that has been reached.
Note: If the milk is frothed, the
Q
2004
15:15:04
Note: When the set temperature is reached, steam supply stops
automatically and the display continues indicating steam value
for the next 3 seconds.
Steam supply can be interrupted at any time (even if the set
temperature was not reached), by again turning the automatic steam
knob (13) in the same direction used for activating supply.
The message "T steam xxx°C"
appears on the display, indicating
the temperature read by the probe.
P
14 January
wednesday
The message "T steam xxx°C"
appears on the display, indicating
the temperature read by the probe.
13
Frothed
milk
Hot milk
If the thermocouple is malfunctioning, the Error Log will list the ES053 error. The latest set temperature value is, however, saved until
thermo-couple operation is restored. The machine works as if it is
in the STOP STEAM mode. You can froth or heat milk, but during the
process, the display will show:
14 January
wednesday
T steam:
2004
15:15:04
- - - °C
The temperature detected by the probe will appear again on the
display once the thermocouple functions again.
symbol appears beside "Steam T:
xxx°C". If the milk is warm, the
"Steam T: xxx°C".
symbol appears beside
Time out is set at 180" for both the programming modes.
BEVERAGE TEMPERATURE READING
The steam probe also detects the beverage temperature, but only if
it is higher than 50°C. Inset the steam nozzle (15) into the container,
making sure the tip is completely submerged in the milk. After a few
seconds the phrase "T steam: xxx°C", corresponding to the probe
reading, appears.
When the steam nozzle is removed from the milk, the phrase remains
on the display for the following 3 seconds.
To view the temperature in Fahrenheit degrees, please refer to the
"configuration menu -Measurement unit" in the technical manual.
A
The ideal setting for milk frothing is set in the factory. If additional
adjustments must be made, turn the flow adjustment valve (A)
underneath the panel control of the machine:
- counterclockwise: more air > more frothy milk
- clockwise: less air > less frothy milk
Note: even slight turns of the valve (A) can make a great
difference in how the milk is frothed.
Anomalie e Guasti - Defects and Malfunctions - Anomalies et Pannes
Anomalien und Störungen - Anomalías y averías - Anomalias e avarias
CODICE
GUASTO DESCRIZIONE
Sonda vapore KO
ES-053
MALFUNCTIONS
DESCRIPTION
CODE
POSSIBILI CAUSE
VERIFICHE
• Termocoppia scollegata.
• Scheda servizi fuori taratura.
• Scheda servizi guasta.
• Controllare collegamenti.
• Sostituire sonda vapore.
• Sostituire scheda servizi.
POSSIBLE CAUSES
VERIFICATIONS
ES-053
KO steam probe
• Thermocuple disconnected
• Utilities card setting wrong
• Malfunctioning utilities card
• Check connections
• Replace steam probe
• Replace utilities card.
CODE
PANNE
DESCRIPTION
CAUSES POSSIBLES
VERIFICATIONS
ES-053
Sonde vapeur KO
• Thermocouple débranché
• Fiche de service pas bien calibrée
• Fiche de services en panne
• Contrôler les branchements
• Remplacer la sonde vapeur
• Remplacer la fiche de
sevices
CODE
STÖRUNG
MÖGLICHE URSACHEN
KONTROLLEN
ES-053
Dampffühler OK
• Thermoelement nicht angeschlossen
• Servicekarte falsch geeicht
• Servicekarte defekt
• Anschlüsse kontrollieren
• Dampffühler austauschen
• Servicekarte austauschen
CÓDIGO
AVERÍA
DESCRIPCIÓN
POSIBLES CAUSAS
CONTROLES
ES-053
Sonda vapor KO
• Termopar desconectado
• Tarjeta servicios fuera regulación
• Tarjeta servicios averiada
• Controlar conexiones
• Sustituir sonda vapor
• Sustituir tarjeta servicios
CÓDIGO
AVARIA
DESCRIÇÃO
CAUSAS POSSÍVEIS
VERIFICAÇÕES
ES-053
Sonda vapor KO
• Termopar desligado
• Ficha de serviços não ajustada
• Ficha de serviços avariada.
• Verificar as ligações
• Substituir a sonda de vapor
• Substituir a ficha de
serviços
Schema idraulico - Hydraulic circuit - Schéma hydraulique - Hydraulikplan Esquema hidraulico - Esquéma hidráulico
ts*
M
=
MC*
Reg*
Ets*
Cs
Sl
Legenda - Legend - Legende - Legende - Leyenda - Legenda
Ets
Elettrovalvola Turbosteam
Turbosteam solenoid valve
Electrovanne Turbosteam
Magnetventil Turbosteam
Electroválvula Turbosteam
Electroválvula Turbosteam
MC
Motore compressore
Compressor motor
Moteur comprimeur
Motor Kompressor
Motor compressor
Motor compressor
Reg
Regolatore aria
Air regulator
Regulateur de l’aire
Lüftregler
Regulador aire
Dispositivo de regulação do ar
Schema elettrico - Wiring diagram Schéma éléctrique - Elektrischer Schaltplan - Esquema electrico - Esquéma electrico
Il Costruttore si riserva il diritto di modificare senza preavviso le caratteristiche
delle apparecchiature presentate in questa pubblicazione
Le Fabricant se réserve le droit de modifier sans préavis les caractéristiques
des appareils présentés dans cette publication
The Manufacturer reserves the right to modify the appliances presented in this
publication without notice
Der Hersteller behält sich das Recht vor, die in dieser Broschüre vorgelegten
Geräte ohne Voranzeige zu ändern
El Constructor se reserva el derecho de modificar sin preaviso las caracteristicas
de las maquinas tratadas en este manual
O Constructor reserva-se o direito de modificar sem aviso previo as máquinas
tratadas neste manual
Code 431 - 584 - 000 (rev. 04/04)
Download PDF