Benchtop Water Quality Meters 1000 Series

pH
ORP
Resistivity
Ion
Total Dissolved Solids
Conductivity
Salinity
Benchtop Water Quality Meters
1000 Series
TE R
ME S
2 YEAR
RA NT
Y
W
AR
MADE IN
J A PA N
www.horiba-laqua.com
Benchtop Water Quality Instruments
1000 Series
Intuitive and easy to use
•
•
•
•
•
Soft-touch operation panel
Scratch-proof and chemical-resistant glass panel
Large display – 5.5 inches
Small footprint – 170(W) x 174(D) x 73(H) mm
Protection cover included
History of the
HORIBA pH Meter
1950
360º Maneuverability
• Light-weight electrode stand can be integrated with meter or
placed separately
• Base of electrode stand can be used as a convenient platform for
placing beakers
• Height-adjust stopper controls vertical slide of electrode stand arm
*Taller electrode stand (650 mm) with telescopic shaft is also available
HORIBA introduces
Japan’s first glass
electrode pH meter.
1964
M-5 (benchtop) From
a vacuum tube to
a semiconductor,
allowing miniaturization
and fast response.
1977
1980
Model F-7AD (benchtop)
Incorporating an
industry-first LCD
display, the combination
of a glass electrode,
a reference electrode
and a temperaturecompensating electrode,
makes testing easier.
| 01
1987
Model F-80 (benchtop)
The world’s first
instrument capable of
measuring pH at 1/1000
resolution, includes an
integral computer, with
automatic calibration and
a self-diagnostic function.
L-7 (integrated)
Introduction of a small,
hand-held pH meter
with the measurement
electrode integrated
within the main device.
1990
C-1 (card)
Development of the
world’s first flat sensor. B-111 (Pen type) Pen
type sensor allows small
samples to be tested.
Electrode Status
• Electrode condition is updated after each
calibration and stored information can be
viewed anytime
• Alert when electrode deteriorates
with usage
• Programmable calibration reminders*
Stability function aids
documentation
• Fuzzy logic determines when measured
value is stable and freezes the reading on
the LCD display
Diagnostic messages
• Meter performs diagnosis at various stages
and reports errors
• Up to 10 error codes facilitate
troubleshooting-specific issues
Data management
• Internal memory with indexed data
• Automatically log measured values to
memory with Auto Log function
• Sample ID for easier sample referencing
• Date / time stamping with real-time clock*
• Output to printer, PC or USB memory-stick*
• RS232C or USB* for data output
GLP / GMP
• Important information such as model number,
serial number, calibration data, electrode
condition and parameters can be printed out*
• Date / time stamping of calibration performed
• Number of calibration points done and value of
calibration solutions recorded
• Electrode parameters are captured and printed*
Data Acquisition Software
• To load measurement data from the meter
into your PC
• Communication cable is sold separately
Universal Power Adapter
• Multi-voltage (100-240V)
• 6 types of international standard plugs
included (US, UK, EU, ANZ, Korea and China)
*For selected models
1993
F-20 (benchtop) The world’s
first wireless pH meter. Large
graphical display gives user
instructions on screen.
2011
2003
F-50 (desktop) World’s first color
LCD display. Navigation panel
guides operators in how to use the
meter as well as resolving errors.
D-50 (portable)
Waterproof IP67rated housing and
multi parameter.
LAQUA Benchtop
Water Quality
Instruments
2012
LAQUAtwin
Pocket Ion Meters
2013
LAQUAHandheld
Water Quality
Instruments
02 |
Benchtop Water Quality Instruments
1000 Series
Sophisticated
Simplicity
Rugged
Reliability
• Fuss-free advanced
meter options
such as Buffer
Selection, Switchable
Resolutions, AutoStable/Auto-Hold
Measurment, Unit
Selections, etc.
| 03
• pH or ORP
measurements in
all pH meters
• Ion measurements in pH
1300 with respective Ion Selective Electrode
• Switchable pH
Resolutions —
0.1, 0.01, 0.001
• Separate acid
and alkaline
slope calculation
• USA, NIST or Custom
buffer options
• Up to 5-point calibration
pH Meters
PH 1100
PH 1200
PH 1300
PH 1100
PH 1200
PH 1300
pH/ORP/Temp (oC)
pH/ORP/Temp (oC)
pH/ORP/Ion/Temp (oC)
-2.00 to 20.00 pH
0.1 / 0.01 pH
±0.01 pH
5
USA, NIST
-2.000 to 20.000 pH
0.1 / 0.01 / 0.001 pH
±0.003 pH
5
USA, NIST, Custom
-2.000 to 20.000 pH
0.1 / 0.01 / 0.001 pH
±0.003 pH
5
USA, NIST, Custom
Resolution
Accuracy
±2000 mV
0.1 mV
±0.2 mV
±2000 mV
0.1 mV
±0.2 mV
±2000 mV
0.1 mV
±0.2 mV
Resolution
Accuracy
Cal points
-----
-----
0.000 µg/L to 9999 g/L
4 significant digits
±0.3% full scale
Up to 5
Temperature range
Resolution
Accuracy
Cal option
-30.0 oC to 130 oC
0.1 oC
±0.4 oC
Yes (±5.0 oC range in 0.1 oC increments)
-30.0 oC to 130 oC
0.1 oC
±0.4 oC
Yes (±5.0 oC range in 0.1 oC increments)
-30.0 oC to 130 oC
0.1 oC
±0.4 oC
Yes (±5.0 oC range in 0.1 oC increments)
Memory
Auto Data-logging
Real time clock
Date/time stamping
500
----
999
Yes
Yes
Yes
Yes
(programmable: 1 to 30 mins)
Yes
Yes, Automatic
Yes
Yes
(independent acid and alkaline slopes depending on
calibration)
Yes
(programmable: 1 to 400 days)
On screen display
Yes
Custom LCD
BNC, phono, DC sockets
USB, RS232C
AC adaptor 100 ~ 240 V, 50/60 Hz
Integrated
500g
170 (L) x 174 (D) x 73 (H) mm
PH1300-S (3999960178)
•PH1300 meter
•electrode stand
•power adaptor
•pH 4.01, 7.01, 10.01, 3.33M KCl solutions (250ml ea)
•9615S-10D - refillable, glass-body pH electrode with
integrated temperature sensor, 1m cable, BNC & phono jack
•Data Acquisition Software
Model
pH range
Resolution
Accuracy
Cal points
Buffer options
ORP range
Ion range
Cal Alarm
--
Electrode status
Diagnostic messages
Display
Inputs
Outputs**
Power requirements
Electrode stand
Weight
Dimensions
On screen display
Yes
Custom LCD
BNC, phono, DC sockets
RS232C
AC adaptor 100 ~ 240 V, 50/60 Hz
Integrated
500g
170 (L) x 174 (D) x 73 (H) mm
999
Yes
Yes
Yes
Yes
(programmable: 1 to 30 mins)
Yes
Yes, Automatic
Yes
Yes
(independent acid and alkaline slopes depending on
calibration)
Yes
(programmable: 1 to 400 days)
On screen display
Yes
Custom LCD
BNC, phono, DC sockets
USB, RS232C
AC adaptor 100 ~ 240 V, 50/60 Hz
Integrated
500g
170 (L) x 174 (D) x 73 (H) mm
PH1100-S (3999960176)
• PH1100 meter
• electrode stand
• power adaptor
• pH 4.01, 7.01, 10.01, 3.33M KCl solutions (250ml ea)
• 9615S-10D - refillable, glass-body pH electrode with
integrated temperature sensor, 1m cable, BNC & phono jack
• Data Acquisition Software
PH1200-S (3999960177)
•PH1200 meter
•electrode stand
•power adaptor
•pH 4.01, 7.01, 10.01, 3.33M KCl solutions (250ml ea)
•9615S-10D - refillable, glass-body pH electrode with
integrated temperature sensor, 1m cable, BNC & phono jack
•Data Acquisition Software
Auto Shut-off
--
Auto-Hold
Averaging/Stability
Offset display
Yes
Yes, Automatic
Yes
Yes
(independent acid and alkaline slopes depending on
calibration)
Slope display
Ordering information:
Kit*
Meter with electrode stand
pH Electrode
• PH1100 meter
• electrode stand
• power adaptor
• protection cover
PH1100 (3200647407)
9615S-10D (3200585428)
• refillable, glass-body pH electrode with integrated
temperature sensor, 1m cable, BNC & phono jack
• PH1200 meter
• electrode stand
• power adaptor
• protection cover
PH1200 (3200647408)
9615S-10D (3200585428)
• refillable, glass-body pH electrode with integrated
temperature sensor, 1m cable, BNC & phono jack
• PH1300 meter
• electrode stand
• power adaptor
• protection cover
PH1300 (3200647409)
9615S-10D (3200585428)
• refillable glass-body pH electrode with integrated
temperature sensor, 1m cable, BNC & phono jack
USA pH buffer set
502-S (3999960016)
pH 4.01, 7.01, 10.01, 3.33M KCl solutions (250ml ea)
502-S (3999960016)
pH 4.01, 7.01, 10.01, 3.33M KCl solutions (250ml ea)
502-S (3999960016)
pH 4.01, 7.01, 10.01, 3.33M KCl solutions (250ml ea)
NIST pH buffer set
501-S (3999960015)
pH 4.01, 6.86, 9.18, 3.33M KCl solutions (250ml ea)
501-S (3999960015)
pH 4.01, 6.86, 9.18, 3.33M KCl solutions (250ml ea)
501-S (3999960015)
pH 4.01, 6.86, 9.18, 3.33M KCl solutions (250ml ea)
*Kit with 501-S is available upon request. Add ‘N’ suffix to the order code when ordering. **Communication cable is sold separately
04 |
Conductivity Meter
Benchtop Water Quality Instruments
1000 Series
EC 1100
• Wide measurement range
EC 1100
Model
EC/TDS/Res/Sal/Temp (oC)
• EC/TDS/Res/Sal in one meter
•Auto-calibration
0.000 to 1.999 µS/cm (k = 0.1)
2.00 to 19.99 µS/cm (k = 0.1, 1)
20.0 to 199.9 µS/cm (k = 0.1, 1, 10)
200 to 1999 µS/cm (k = 0.1, 1, 10)
2.00 to 19.99 mS/cm (k = 0.1, 1, 10)
20.0 to 199.9 mS/cm (k = 1, 10)
0.200 to 2.000 S/cm (k = 10)
EC range
• Multi-calibration points
• Preset TDS calibration curves
• Preset Salinity calibration curves
• Rugged conductivity cell construction
Resolution
0.05% F.S.
Accuracy
±0.6% F.S.
(±1.5% F.S. > 18.0 mS/cm)
Ref. temp.
15 to 30 oC (selectable)
Temp. coefficient
0.00 to 10.00% (selectable)
Cell constants
0.1 / 1.0 / 10.0
Cal points
4 points (Auto/Manual)
Units setting
Auto ranging / Manual
µS/cm or mS/cm or S/m
TDS Calibration Curves
Key chemical
species
Application
TDS selection
Aquaculture, pickling
NaCl
NaCl
Boiler water, HVAC
Na 2SO 4, NaHCO3, NaCl
442 (Myron)
Environmental
EN standard for
environmental water
EN 27888
Not known
KCl (linear factor)
Default: 0.5
Selectable: 0.4 to 1.0
General application
0.01 to 9.99 mg/L
10.0 to 99.9 mg/L
100 to 999 mg/L
1.00 to 9.99 g/L
10.0 to 99.9 g/L
100 g/L
TDS range
±0.1% F.S.
EN27888, 442, Linear (0.40 to 1.00), NaCl
0.000 to 1.999 kΩ•cm (k = 1)
2.00 to 19.99 kΩ•cm (k = 0.1, 1)
20.0 to 199.9 kΩ•cm (k = 0.1, 1)
0.200 to 1.999 MΩ•cm (k = 0.1, 1)
2.00 to 19.99 MΩ•cm (k = 0.1, 1)
20.0 to 200.0 MΩ•cm (k = 0.1)
Resistivity Range
10000
TDS (mg/L)
0.01 mg/L
Accuracy
TDS curves
EN 27888 Curve
12000
Resolution
Resolution
0.05% F.S.
Accuracy
±0.6% F.S.
(±1.5% F.S. > 1.80 MΩ•cm)
8000
0.00 to 100.00 ppt
0.000 to 10.000 %
Salinity
6000
Resolution
4000
2000
0
0
5
10
15
20
25
Conductivity (mS/cm)
0.01 ppt / 0.001%
Accuracy
±0.2% F.S.
Cal curves
NaCl / Sea water
Temperature range
442 (Myron) Curve
-30.0 oC to 130 oC
Resolution
0.1 oC
Accuracy
±0.4 oC
90000
80000
70000
TDS442 / ppm
60000
50000
Memory
500
Auto-Hold/Stability
Yes
Diagnostic messages
Yes
Display
Custom LCD
Inputs
BNC, phono, DC sockets
Outputs**
USB, RS232C
Power requirements
AC adaptor 100 ~ 240 V, 50/60 Hz
30000
Electrode stand
Integrated
20000
Weight
500g
Dimensions
170 (L) x 174 (D) x 73 (H) mm
40000
10000
0
Ordering information:
0
20000
40000
60000
80000
100000
Conductivity µS/cm
NaCl Curve
300
Kit
COND / mS/cm-1
250
200
Meter with electrode
stand
150
100
50
0
Conductivity cell
0
1000
2000
3000
NaCl / mM
4000
5000
6000
Conductivity standard
solutions set
*Kit with 501-S is available upon request. Add ‘N’ suffix to the order code when ordering. ** Communication cable sold separately.
| 05
EC1100-S (3999960179)
• EC1100 meter
• electrode stand
• power adaptor
• 84uS/cm, 1413 uS/cm, 12.88 mS/cm, 111.8 mS/cm solutions (250ml ea)
• 9382-10D - plastic-body, k=1.0 conductivity cell with integrated temperature
sensor, 1m cable, BNC & phono jack
• Data Acquisition Software
• EC1100 meter
• electrode stand
• power adaptor
• protection cover
EC1100 (3200647411)
9382-10D (3014046709)
• plastic-body, k=1.0 conductivity cell with integrated temperature sensor, 1m cable,
BNC & phono jack
503-S (3999960017)
• 84uS/cm, 1413 uS/cm, 12.88 mS/cm, 111.8 mS/cm solutions (250ml ea)
Multi-Parameter Meter
PC 1100
• pH/ORP/EC/TDS/Res/Sal/Temp (ºC) in one meter
• Combination of PH 1200 & EC 1100
• Simultaneous measurement on 2 channels
Model
PC 1100
Dual Channel pH/ORP/ EC/TDS/Res/Sal/Temp (oC)
pH range
-2.000 to 20.000 pH
Resolution
0.1 / 0.01 / 0.001 pH
Accuracy
±0.003 pH
Cal points
5
Buffer options
ORP range
USA, NIST, Custom
±2000 mV
Resolution
0.1 mV
Accuracy
±0.2 mV
0.000 to 1.999 µS/cm (k = 0.1)
2.00 to 19.99 µS/cm (k = 0.1, 1)
20.0 to 199.9 µS/cm (k = 0.1, 1, 10)
200 to 1999 µS/cm (k = 0.1, 1, 10)
2.00 to 19.99 mS/cm (k = 0.1, 1, 10)
20.0 to 199.9 mS/cm (k = 1, 10)
0.200 to 2.000 S/cm (k = 10)
EC range
Resolution
0.05% F.S.
Accuracy
Ref. temp.
Temp. coefficient
Cell constants
• Dual channel, dual display
Memory
999
Auto Data-logging
Yes
Real time clock
Yes
Date/time stamping
Yes
±0.6% F.S.
(±1.5% F.S. > 18.0 mS/cm)
Auto Shut-off
Yes (programmable: 1 to 30 mins)
Auto-Hold
Yes
15 to 30 oC (selectable)
Averaging/Stability
Yes, Automatic
0.00 to 10.00% (selectable)
Offset display
Yes
Slope display
Yes (independent acid and alkaline slopes
depending on calibration)
0.1 / 1.0 / 10.0
Cal points
4 points (Auto/Manual)
Cal Alarm
Yes
(programmable: 1 to 400 days)
Units setting
Auto ranging / Manual
µS/cm or mS/cm or S/m
Electrode status
On screen display
Diagnostic messages
Yes
Display
Custom LCD, Dual channel display
Inputs
Dual BNC, dual phono, DC sockets
0.01 to 9.99 mg/L
10.0 to 99.9 mg/L
100 to 999 mg/L
1.00 to 9.99 g/L
10.0 to 99.9 g/L
100 g/L
TDS range
Resolution
0.01 mg/L
Accuracy
±0.1% F.S.
TDS curves
EN27888, 442, Linear (0.40 to 1.00), NaCl
0.000 to 1.999 kΩ•cm (k = 1)
2.00 to 19.99 kΩ•cm (k = 0.1, 1)
20.0 to 199.9 kΩ•cm (k = 0.1, 1)
0.200 to 1.999 MΩ•cm (k = 0.1, 1)
2.00 to 19.99 MΩ•cm (k = 0.1, 1)
20.0 to 200.0 MΩ•cm (k = 0.1)
Resistivity Range
Resolution
0.05% F.S.
Accuracy
±0.6% F.S.
(±1.5% F.S. > 1.80 MΩ•cm)
Outputs**
USB, RS232C
Power requirements
AC adaptor 100 ~ 240 V, 50/60 Hz
Electrode stand
Integrated
Weight
500g
Dimensions
170 (L) x 174 (D) x 73 (H) mm
Ordering information:
Kit*
Meter with electrode stand
0.00 to 100.00 ppt
0.000 to 10.000 %
Salinity
Resolution
0.01 ppt / 0.001%
Accuracy
±0.2% F.S.
Cal curves
NaCl / Sea water
Temperature range
-30.0 oC to 130 oC
Resolution
0.1 oC
Accuracy
±0.4 oC
pH Electrode
Conductivity cell
PC1100-S (3999960180)
• PC1100 meter
• electrode stand
• power adaptor
• 9615S-10D - refillable, glass-body pH electrode with integrated
temperature sensor, 1m cable, BNC & phono jack
• 9382-10D - plastic-body, k=1.0 conductivity cell with integrated
temperature sensor, 1m cable, BNC & phono jack
• pH 4.01, 7.01, 10.01, 3.33M KCl solutions (250ml ea)
• 84uS/cm, 1413 uS/cm, 12.88 mS/cm, 111.8 mS/cm solutions
(250ml ea)
• Data Acquisition Software
• PC1100 meter
• electrode stand
• power adaptor
• protection cover
PC1100 (3200647410)
9615S-10D (3200585428)
• refillable, glass-body pH electrode with integrated temperature
sensor, 1m cable, BNC & phono jack
9382-10D (3014046709)
• plastic-body, k=1.0 conductivity cell with integrated temperature
sensor, 1m cable, BNC & phono jack
USA pH buffer set
502-S (3999960016)
• pH 4.01, 7.01, 10.01, 3.33M KCl solutions (250ml ea)
NIST pH buffer set
501-S (3999960015)
• pH 4.01, 6.86, 9.18, 3.33M KCl solutions (250ml ea)
Conductivity standard
solutions set
503-S (3999960017)
• 84uS/cm, 1413 uS/cm, 12.88 mS/cm, 111.8 mS/cm solutions
(250ml ea)
*Kit with 501-S is available upon request. Add ‘N’ suffix to the order code when ordering. ** Communication cable sold separately.
06 |
pH Electrode
Selection Guide
Applicable temperature
range (ºC)
Specification
3-in-1 ELECTRODES
STANDARD
ToupH
PLASTIC
9625-10D
9630-10D
9631-10D
0-100
0-100
0-60
LONG
ToupH
MICRO
ToupH
COMBINATION ELECTRODES
SLEEVE
ToupH
SLEEVE
9632-10D 9615S-10D 9680S-10D 9618S-10D 9681S-10D 6367-10D
0-100
0-100
0-100
0-60
0-60
0-60
NONAQUEOUS
NEEDLE
PLASTIC
STANDARD
ToupH
MICRO
ToupH
SLEEVE
ToupH
LONG
6377-10D
6252-10D
9425-10C
9415-10C
9418-10C
9481-10C
6069-10C
0-60
0-60
0-100
0-100
0-60
0-60
0-60
Diameter (mm)
16
16
16
16
12
8
3
12
12
12
12
16
12
3
12
3
Length (mm)
150
150
155
150
198
283
185
203
150
150
150
150
198
185
203
291
pH - Sample Conditions
Normal (over 100
mS/m)
Low (approx.10
~100 mS/m
Very low (approx.
5 ~100 mS/m
High (approx.
5 S/m)
Conductivity
Aqueous
Solution
Strong alkaline (pH 10-12)
Strong acidity (pH 0-2) * Except
HF sample
Quick heat change (within 50°C)
High viscosity (approx. 5 Pa·S)
Containing non-aqueous
solvent
Suspension
Solid/
Semisolid
Inside
Surface
Microtube/plate (> 50 µL)
Ampule
> ø4 mm
Micro container (> 2 mL)
Sample
Containers
Tube
ID:13 mm, L:100 ~
150 mm
Beaker
10 mL ~ 1 L
Large container (> 1 L)
Petri dish
Droplet
Water
Pure/ion-exchange water
(approx. 0.1 mS/m)/ Distilled
water (approx. 0.5 mS/m)
Tap/drinking water (approx.
10 mS/m)
Surface water
Pharmaceutical water/
Enviromental water/acid rain
Caustic/strong acid (Except
HF sample)
Chemical
reagent/
solvent
Hydrofluoric acid
Surfactant
Water-based paint
Dye/coloring agent
Protein-containing sample
Medicinal preparation
Pharmaceutical/
biological
sample
Enzyme solution
Tris buffer
Suspension
Agar medium
Jam
Meat/fish/Fruit/vegetable/
Dough
Food
Honey
Cheese/butter
Yogurt
Beer
Beverage/
seasoning
Milk/Carbonated drink/juice/
sauce/soy sauce
Mayonnaise/ketchup
Beauty cream/mascara
Cosmetic/
lotion
Gel/soap/shampoo/Hairdye
lotion
Emulsified liquid
Recommended
| 07
Can be measured
ISFET
ELECTRODE
LONG
ToupH
FLAT
GENERAL
9480-10C
6261-10C
0040-10D
0-100
0-50
0-60
8
12
16
283
150
190
Stable measurement for a wide range of samples. Standard
STANDARD
water
proof
glass electrode (9615S-10D)
Pb
Free
High stability and drift reduction. No more worries about the timing of your measurement value readings.
•
Uses responsive glass that is 10 times stronger than JIS standard. The domed shape provides strength in all
directions, greatly reducing damage concerns.
•
Constructed with smooth surfaces for easy wiping and cleaning.
Recommended
Perfect for preparing buffers. Can be used on a wide range of aqueous test solutions.
Stable measurement for routine testing. Standard plastic electrode (9625-10D)
STANDARD
water
proof
Pb
Free
The electrode has a plastic body which is ideal for general purpose measurement.
•
Can be submerged up to 1m depth and 30mins. (with refilling port closed)
•
Waterproof, Pb-free
Recommended
Ideal for general purpose use. For measurement of tap water and drinking water.
For extremely small samples Micro
MICRO
glass electrode (9618S-10D)
water
proof
This pH electrode with temperature compensation sensor can take
measurements from samples as small as 50μL, the smallest in the world.
•
Our original manufacturing technology (Japanese Patent No. 4054245) is used to produce 2-ply piping
3mm in diameter.
•
Compatible with extremely small containers such as micro tubes etc.
•
The temperature sensor is located at the tip for high-speed temperature response. Refrigerated samples
can be measured without needing to wait for them to return to room temperature.
Recommended
Can be used for a wide range of aqueous solutions, including those that cannot be obtained in large quantities.
We recommend using our specialized cleaning solution after measuring samples that contain proteins.
For using a large container Long
LONG
water
proof
glass electrode (9680S-10D)
Pb
Free
283 mm length & 8 mm diameter. The long, thin design makes this electrode perfect for measuring in large containers
and test tubes.
•
Uses responsive glass that is 10 times stronger than JIS standard. The domed shape provides strength in all
directions, greatly reducing damage concerns.
Recommended
For measuring samples such as microbe culture fluids in test tubes.
We recommend that it be used with the long type electrode stand (FA-70L).
For highly viscous samples Sleeve
SLEEVE
water
proof
glass electrode (9681S-10D)
Pb
Free
Stable measurement can also be achieved for high viscous samples.
•
The liquid junction section is constructed with a moveable sleeve that can be rinsed clean,
preventing highly viscous samples from clogging the liquid junction, and maintaining stable
measurement performance
Recommended
For highly viscous samples and solutions, and samples that contain non-aqueous solvents (such as
cosmetics or paints). We recommend that you take measurements while using the graph display function
to confirm stable responses.
(We recommend washing with a neutral detergent after use with samples that contain oil.)
(surface)
(surface)
(surface)
(surface)
(surface)
For the surface of solid samples General ISFET pH electrode (0040-10D)
GENERAL
water
proof
The sensor is located on the flat surface of the electrode tip,
with less than a 100 μm protrusion from the housing.
•
Measurements can be made from a minute amount of moisture on the solid sample surface.
•
Use of a semiconductor sensor means there are no concerns that the electrode will be damaged.
•
Also perfect for measuring samples in shallow containers such as Petri dishes.
•
Repalceable sensor
Recommended
For highly viscous samples and solutions, and samples that contain non-aqueous solvents (such
as cosmetics or paints). We recommend that you take measurements while using the graph display
function to confirm stable responses.
(We recommend washing with a neutral detergent after use with samples that contain oil.)
08 |
Combination ISE
Ion-selective electrodes are responsive to concentration of particular ions in the test liquid and are variable-potential electrodes. They are used in
conjunction with reference electrodes to measure the concentration of particular ions. HORIBA’s years of experience and know-how in this field are
behind the wide range of ion electrodes we offer.
When measurements are made using an ion meter, calibrating it with various standard solutions will give direct readings of the ion
concentration. Note that since volume-detection level changes with temperature, measurements must be taken at a fixed temperature.
Model
Accessories Included
Ammonia ion (NH3) electrode
5002S-10C
• membrane cap, 3pcs
• 1000mg/L ammonium ion standard solution,
50ml
• 100mg/L ammonium ion standard solution,
50ml
• ammonia electrode filling solution, 50ml
• syringe
• dropper
• protective pipe
• manual
Calcium ion (Ca2+) electrode
6583S-10C
• calcium electrode tip, 2pcs
• 1000mg/L calcium ion standard solution, 50ml
• 100mg/L calcium ion standard solution, 50ml
• calcium electrode filling solution, 50ml
• calcium ionic strength adjustor, 50ml
• syringe
• dropper
• protective pipe
• manual
3200698386
Overall length: 161 mm
Diameter of probe: 15 mm
Connector: BNC
3200697410
Overall length: 150 mm
Diameter of probe: 16 mm
Connector: BNC
Temp.
Range
(C)
Measurement
Range
pH Range
0 - 50
0.01 - 18,000
mg/L NH4+
(5 x 10 -7 to 1
mol/L NH4+)
pH 12 or
more
0 - 50
0.4 - 40,080
4.0 mg/L (10 -4
mg/L Ca2+
mol/L) Ca2+,
(10 -5 to 1 mol/L
pH 5 to 11
2+
Ca )
• chloride electrode tip
• 1000mg/L chloride ion standard solution, 50ml
• 100mg/L chloride ion standard solution, 50ml
• chloride electrode filling solution, 50ml
• chloride ionic strength adjustor, 50ml
• syringe
• dropper
• protective pipe
• water-resistant abrasive sheet
• manual
0 - 50
Fluoride ion (F-) electrode
6561S-10C
• fluoride electrode tip
• 1000mg/L fluoride ion standard solution, 50ml
• 100mg/L fluoride ion standard solution, 50ml
• fluoride electrode filling solution, 50ml
• fluoride ionic strength adjustor, 50ml
• syringe
• dropper
• protective pipe
• manual
0 - 50
0.02 - 19,000
mg/L F(10 -6 to 1 mol/L
F-)
0.1 to 1,000
mg/L F-,
pH 5 to 8
Nitrate ion (NO3-) electrode
6581S-10C
• nitrate electrode tip, 2pcs
• 1000mg/L nitrate ion standard solution, 50ml
• 100mg/L nitrate ion standard solution, 50ml
• nitrate electrode filling solution, 50ml
• nitrate ionic strength adjustor, 50ml
• syringe
• dropper
• protective pipe
• manual
0 - 50
0.62 - 62,000
mg/L NO3(10 -5 to 1 mol/L
NO3-)
62 mg/L (10 -3
mol/L) NO3-,
pH 3 to 7
0 - 50
0.39 - 39,000
3.9 mg/L (10 -4
mg/L K+
mol/L) K+,
-5
(10 to 1 mol/L
pH 5 to 11
K+)
Chloride ion (Cl-) electrode
6560S-10C
3200697407
Overall length: 150 mm
Diameter of probe: 16 mm
Connector: BNC
3200693774
Overall length: 150 mm
Diameter of probe: 16 mm
Connector: BNC
3200697408
Overall length: 150 mm
Diameter of probe: 16 mm
Connector: BNC
Potassium ion (K+) electrode
6582S-10C
3200697409
Overall length: 150 mm
Diameter of probe: 16 mm
Connector: BNC
| 09
• potassium electrode tip, 2pcs
• 1000mg/L potassium ion standard solution,
50ml
• 100mg/L potassium ion standard solution,
50ml
• potassium electrode filling solution, 50ml
• potassium ionic strength adjustor, 50ml
• syringe
• dropper
• protective pipe
• manual
0.35 - 35,000
350 mg/L (10 -2
mg/L Cl(10 -5 to 1 mol/L
mol/L) Cl-,
Cl-)
pH 3 to 11
Selection Coefficient
—
Replacement Tip
NH3 electrode
membrane caps
Electrode
Filling Solution
500-NH3-IFS
3200697173
3200705774
Fe3+ = 0.1, Fe2+, Zn2+ = 1, Sr2+ = 50
Ni2+, Cu2+ = 70, Co2+ = 350
Mn2+ = 500, Mg2+ = 1,000
Na+, K+, Ba2+, NH4+ = over 1,000
S2O32-, S2-, I-, Ag+, Hg2+ = Not
acceptable
SCN -= 0.3, MnO4-= 0.1
Br-= 0.03
NO3-, F-, HCO3-, SO42-, PO42-= 1,000
Possible interference when
multiply-charged ion (ex. Al3+, Fe3+)
coexisted and foamed the complex.
ClO4-, I- = Not acceptable, Br-= 2
NO2-= 3, Cl- = 300
HCO3-, H2PO4-, SO42-=over 1000
Rb+ = 0.4, Cs+ = 3, NH4+ = 70
Li+, Na+, Mg2+, Ca2+, Sr2+, Ba2+ = over
1,000
7683S
500-CA-IFS
3200697177
100mg/L
Standard
Solution
500-CL-IFS
3200697169
3200697411
7661S
3200693606
7681S
3200697412
7682S
3200697413
Ionic Strength
Adjustor
Applications
Agriculture, Soil,
Power Station Water,
Fish Tanks, Sea
500-NH4-SL 500-NH4-SH 500-NH3-ISA Water, Waste Water,
3200697172 3200697171 3200697174 Plating Baths, Air /
Stack Gases and
Biological Cultures
or Samples
500-CA-SL
3200697176
3200697414
7660S
1000mg/L
Standard
Solution
500-CL-SL
3200697168
500-CA-ISA
3200697178
Agriculture / Plant
Tissue, Soil, Water
Softening Systems,
Boiler Feed Water,
Drinking / Mineral
Water, Biological
Cultures, Dental /
Clinical Analysis
and Dairy / Food
/ Beverages
Applications
500-CL-SH
3200697167
500-CL-ISA
3200697170
Agriculture, River
/ Tap Water, Plant
Tissue, Soils, Boiler
Feed Water, Clinical
Analysis, Sweat,
Urine, Cement,
Plating Baths and
Dairy / Food /
Beverages Samples
500-F-SH
3200697163
Dental / Toothpaste
/ Mouth Wash,
Drinking / Seawater,
Wastewater, Air
/ Stack Gases,
500-F-TISAB
Acids, Soils, Food,
3200697166
Biological Fluids,
Plant Tissue,
Coal, Carbonated
Beverages and
Bone
500-CA-SH
3200697175
500-F-IFS
3200697165
500-F-SL
3200697164
500-NO3-IFS
3200697181
Agriculture / Plant
Tissue / Fertilizers,
Surface / Seawater
500-NO3500-NO3-SL
500-NO3-ISA / Drinking Water,
SH
3200697180
3200697182 Sewage Effluent,
3200697179
Soils, Meats,
Vegetables, Foods /
Beverages
500-K-IFS
3200697185
500-K-SL
3200697184
500-K-SH
3200697183
Note: Detailed information on standard solutions, ISAs, and filling solutions can be found on page 13
500-K-ISA
3200697186
Agriculture / Plant
Tissue, Soils,
Wastewater, River /
Tap Water, Clinical
Analysis, Saliva,
Serum, Fertilizers,
Soils and Wines,
Dairy / Foods /
Beverages
10 |
Metallic Electrode (For ORP Measurement)
Model
Operating
Temperature
Range (°C)
Electrode
Material
Internal
Solution
0-60
Pt / Glass
#300
(KCl)
Applications
ORP Electrode
9300-10D Waterproof platinum 3-in-1 type
Waterproof; Platinum on the flat tip allows
measurement of small volume samples
Overall length: 150 mm
Diameter of probe: 12 mm
Connectors: BNC & phono jack
3014046710
Conductivity Cells (Submersible Type)
Model
3551-10D
3014081712
Overall length: 175 mm
Diameter of probe: 23 mm
Connectors: BNC & phono jack
3552-10D
3014081545
Overall length: 150 mm
Diameter of probe: 12 mm
Connectors: BNC & phono jack
Overall length: 175 mm
Width of probe: 28 mm
Connectors: BNC & phono jack
9382-10D
3014046709
Measurement Range
0.1 cm-1
0.1 µS/cm - 10 mS/cm
10 m
-1
1 cm-1
3553-10D
3014081714
Cell
Constant
Overall length: 150 mm
Diameter of probe: 16 mm
Connectors: BNC & phono jack
Application
Built-in
50
Low
conductivity
water (e.g.,
deionized,
distilled)
Pt-Pt black /
Glass
Built-in
15
General
purpose use
0 - 60
Pt-Pt black /
Glass
Built-in
50
High
conductivity
water
0 - 80
Ti-Pt black /
Plastic
Built-in
20-30
General
purpose use;
Waterproof
Temp.
Range
(ºC)
Cell Material
Thermistor
Minimum
Sample
Volume
(ml)
Application
0 - 60
Pt-Pt black /
Glass
Built-in
10
Low
conductivity
water (e.g.,
deionized,
distilled)
0 - 60
Pt-Pt black /
Glass
Built-in
16
General
purpose use
0 - 60
Pt-Pt black /
Glass
­—
4
High
conductivity
water
0 - 60
Pt-Pt black /
Glass
­­—
0.25
Small volume
sample (e.g.,
column chromatography)
Cell Material
0 - 60
Pt-Pt black /
Glass
0 - 100
Thermistor
10 µS/m - 1 S/m
1 µS/cm - 100 mS/cm
100 m-1
0.1 mS/m - 10 S/m
10 cm-1
10 µS/cm - 1 S/cm
1000 m-1
1 mS/m - 100 S/m
1 cm-1
1 µS/cm - 100 mS/cm
100 m-1
Minimum
Sample
Volume
(ml)
Temp.
Range
(ºC)
0.1 mS/m - 10 S/m
Conductivity Cells (Flow Type)
Model
3561-10D
3014082350
Overall length: 143 mm
Diameter of probe: 18 mm
Connectors: BNC & phono jack
3562-10D
3014082350
Overall length: 205 mm
Diameter of probe: 18 mm
Connectors: BNC & phono jack
Overall length: 222 mm
Diameter of probe: 18 mm
Connector: BNC
3574-10C
3014082592
| 11
Measurement Range
0.1 cm-1
0.1 µS/cm - 10 mS/cm
10 m
-1
1 cm-1
3573-10C
3014082590
Cell
Constant
Overall length: 136 mm
Diameter of probe: 66 mm
Connector: BNC
10 µS/m - 1 S/m
1 µS/cm - 100 mS/cm
100 m -1
0.1 mS/m - 10 S/m
10 cm-1
10 µS/cm - 1 S/cm
1000 m-1
1 mS/m - 100 S/m
10 cm-1
10 µS/cm - 100 mS/
cm
1000 m-1
1 mS/m - 10 S/m
pH Buffer Solution Kits
Code
Part No.
Description
Volume
501-S
3999960015
NIST pH Buffer Solution Kit
(pH 4.01, 6.86, 9.18 buffers & 3.33M KCl)
250ml each
502-S
3999960016
USA pH Buffer Solution Kit
(pH 4.01, 7.00, 10.01 buffers & 3.33M KCl )
250ml each
pH Buffer Solutions
501-S NIST pH Buffer Solution Kit
Code
502-S USA pH Buffer Solution Kit
Part No.
Description
Volume
500-2
3999960028 pH 1.68 Buffer Solution at 25C
500ml
500-4
3999960029 pH 4.01 Buffer Solution at 25C
500ml
500-686
3999960030 pH 6.86 Buffer Solution at 25C
500ml
500-7
3999960031 pH 7.00 Buffer Solution at 25C
500ml
500-9
3999960032 pH 9.18 Buffer Solution at 25C
500ml
500-10
3999960033 pH 10.01 Buffer Solution at 25C
500ml
500-12
3999960034 pH 12.46 Buffer Solution at 25C
500ml
Conductivity Standard Solution Kit
Code
503-S
Part No.
3999960017
Description
Conductivity Standard Solution Kit
(84µS/cm, 1413µS/cm, 12.88mS/cm & 111.8mS/cm)
Volume
250ml each
Conductivity Standard Solutions
503-S Conductivity Standard Solution Kit
Code
Part No.
Description
Volume
500-21
3999960035 84 µS/cm Conductivity Standard Solution
500ml
500-22
3999960036 1413 µS/cm Conductivity Standard Solution
500ml
500-23
3999960037 12.88 mS/cm Conductivity Standard Solution
500ml
500-24
3999960038 111.8 mS/cm Conductivity Standard Solution
500ml
ORP Powders
Code
ORP Powders
Part No.
Description
Volume
160-51
3200043618
89 mV at 25°C (for 250ml solution)
10 sachets/pack
160-22
3200043617
258 mV at 25°C (for 250ml solution)
10 sachets/pack
pH/ORP Electrode Filling Solutions
Code
220
250
Cleaning Solutions
Description
Volume
525-3
3999960023 3.33M KCl
250ml
300
3200043640 3.33M KCl
250ml
pH Electrode Cleaning Solutions
Code
230
Part No.
Part No.
Description
220
3014028653
For removing inorganic residues from glass
membrane and liquid junction
230
3200530494
For removing inorganic and organic residues from
glass membrane (30ml Solution A & 100ml Solution B)
250
3200366771
For removing protein residues from glass
membrane and liquid junction
Volume
2 x 50ml
30ml & 100ml
400ml
12 |
Ion Standard Solutions
Code
Part No.
Description
Volume
500-NH4-SH
3200697171
1000 mg/L Ammonium Ion Standard Solution
500ml
500-NH4-SL
3200697172
100 mg/L Ammonium Ion Standard Solution
500ml
500-CA-SH
3200697175
1000 mg/L Calcium Ion Standard Solution
500ml
500-CA-SL
3200697176
100 mg/L Calcium Ion Standard Solution
500ml
500-CL-SH
3200697167
1000 mg/L Chloride Ion Standard Solution
500ml
500-CL-SL
3200697168
100 mg/L Chloride Ion Standard Solution
500ml
500-F-SH
3200697163
1000 mg/L Fluoride Ion Standard Solution
500ml
500-F-SL
3200697164
100 mg/L Fluoride Ion Standard Solution
500ml
500-NO3-SH
3200697179
1000 mg/L Nitrate Ion Standard Solution
500ml
500-NO3-SL
3200697180
100 mg/L Nitrate Ion Standard Solution
500ml
500-K-SH
3200697183
1000 mg/L Potassium Ion Standard Solution
500ml
500-K-SL
3200697184
100 mg/L Potassium Ion Standard Solution
500ml
Calcium Ion Electrode Solutions
Chloride Ion Electrode Solutions
Fluoride Ion Electrode Solutions
Ionic Strength Adjustors
Potassium Ion Electrode Solutions
Code
Part No.
Description
Volume
500-NH3-ISA
3200697174
Ammonia Ionic Strength Adjustor
500ml
500-CA-ISA
3200697178
Calcium Ionic Strength Adjustor
500ml
500-CL-ISA
3200697170
Chloride Ionic Strength Adjustor
500ml
500-F-TISAB
3200697166
Fluoride Ionic Strength Adjustor
500ml
500-NO3-ISA
3200697182
Nitrate Ionic Strength Adjustor
500ml
500-K-ISA
3200697186
Potassium Ionic Strength Adjustor
500ml
Ion Selective Electrode Filling Solutions
Ammonia Ion Electrode Solutions
Code
Part No.
Description
Volume
500-NH3-IFS
3200697173
Ammonia Electrode Filling Solution
500ml
500-CA-IFS
3200697177
Calcium Electrode Filling solution
500ml
500-CL-IFS
3200697169
Chloride Electrode Filling Solution
500ml
500-F-IFS
3200697165
Fluoride Electrode Filling Solution
500ml
500-NO3-IFS
3200697181
Nitrate Electrode Filling Solution
500ml
500-K-IFS
3200697185
Potassium Electrode Filling Solution
500ml
Nitrate Ion Electrode Solutions
| 13
Accessories
Printer cable (1.5 m)
3014030149
Printer paper (20 rolls)
3014030150
Ink ribbon (5 pcs/set)
3200647413
Multi-Voltage (100-240V) with 6 plugs, (US, UK,
EU, ANZ, Korea and China)
1.8 m cable
3014028368
Digital simulator X-51 (pH, mV, Ion, DO, temperature simulator)
3014028370
Digital simulator X-52 (Conductivity, temperature
simulator)
3200382462
LCD protection sheet (2 pcs/pack)
Universal AC adapter
X-52
3200382441
170mm
Protection cover (Protects the meter for F-70, DS70, 1000 series)
USB cable (to connect meter and PC.)
3014030152
Analog cable (Analog (alarm) output cable)
3014030151
Serial cable (to connect meter and PC (Serial, 9
pins))
FA-70A
3200644455
Integrated Electrode Stand (Height: 338mm) for
bench meter
FA-70S
3200382557
Adjustable, free-standing electrode stand
(Height: 384 mm)
FA-70L
3200382560
Long, free-standing electrode stand (Height:
450-650mm)
3200373991
Arm for electrode stand FA-70A, FA-70S, & FA70L
Serial
cable
Integrated Electrode Stand
FA-70A (383mm)
225mm
3200373941
USB
cable
Integrated Electrode Stand
3200373961
Electrode holders, 2pcs (for mounting electrode
with round cap on electrode stand arm)
3200382477
Electrode protection caps, 3pcs (for 9615S-10D,
9618S-10D,
9681S-10D pH electrode)
3200043508
Electrode protection caps, 5pcs (for 9621-10D,
9625-10D, 9630-10D, 9631-10D, 9632-10D,
6367-10D, 6377-10D, 6252-10D,
6261-10C, 1066A-10C, 1076-10C, 2060-10T,
9300-10D, 9382-10D, 3552-10D pH electrode)
3200382482
Electrode protection cap for long electrode (for
9680S-10D, 9480-10C pH Electrode)
Long Electrode Stand
※Stretch shaft
Standard
Electrode Stand
160mm
Standard Electrode Stand
FA-70S (384mm)
343mm(arm movable range)
LCD
Protection
protection cover
sheet
170mm
307mm
X-51
73mm
3014030148
174mm
Printer (for GLP/GMP compliance) Cable sold
separately, Plain paper
383.4mm
Printer
paper
3014030147
(230v)
3014030146
(120v)
650mm ※When arm is housed 450mm
Ink
ribbon
Printer
cable
Description
338mm
(arm movable range)
Printer
Meter Body
Part No.
46mm
Code
195mm
Long Electrode Stand
FA-70L (450~650mm)
14 |
Wolf Laboratories Limited
www.wolflabs.co.uk
Tel: 01759 301142
Fax:01759 301143
sales@wolflabs.co.uk
Use the above details to contact us if this literature doesn't answer all your
questions.
Pricing on any accessories shown can be found by keying the part number
into the search box on our website.
The specifications listed in this brochure are subject to change by the manufacturer and therefore cannot be guaranteed to be
correct. If there are aspects of the specification that must be guaranteed, please provide these to our sales team so that details can