About Us
¡
¡
Founded & established in 1983 as
Hi-Rel Electronics Pvt. Ltd., we are now a
100% Hitachi group company – Hitachi HiRel Power Electronics Pvt. Ltd., recognized
as a pioneer in power electronics. More than
3 decades of experience, we have garnered
a significant level of trust in our market
segment and continue to offer world class
power electronics products, value added
services & customized solutions.
Leading Manufacturer of UPS, DRIVES and SOLAR INVERTERS
State-of-the-Art MANUFACTURING FACILITY at Gandhinagar &
Sanand in Gujarat, India
IN-HOUSE R&D Facility recognized by DSIR, Government of India
ISO 9001:2015, ISO 14001:2015 & BS OHSAS 18001:2007 Certified
Company adhering to World Class Quality Standards with Export
House Status
APPROVED by Leading Consultants and EPC Vendors
PAN INDIA & GLOBAL Presence
SERVING Entire Gamut of Industries
Rich Experience in "MISSION CRITICAL" Applications
Dedicated & Decentralized 24X7 AFTER SALESSERVICE at
45+ Locations
OFFERS Products with Greater Energy Efficiency & Lower Carbon
Footprint
¡
¡
¡
¡
¡
¡
¡
Our state-of-the-art product portfolio
includes UPS for Industrial (non-IT) and IT &
commercial applications, medium & low
voltage variable frequency drives, solar
inverters and railway products.
¡
UPS and Power Conditioning Solutions
With expertise, experience and an efficient product line, we will always be your power electronics partner.
When you choose to do business with us, you are partnering with a company who cares.
Pan India
Presence
Jammu & Kashmir
Jammu
Amritsar
Ludhiana
Chandigarh
Punjab
Bhadla
Hisar
Noida
Jaipur
Jodhpur
Barmer
Mandi
Himachal
Pradesh
Haryana
Uttara
khand
Dehradun
Moradabad
Lucknow
Indore
Bhopal
Kanpur
Gwalior
Ajmer
Udaipur
Gandhinagar
Ahmedabad
Mehsana
Sanand
Mundra
Jamnagar
Rajkot
Baroda
Ankleshwar
Surat
Vapi
Uttar
Pradesh
Nashik Mumbai
Pune
Sasan
Korba
Jharkhand
Bokaro
West
Bengal
Kolkata
Jamshedpur
Jajpur
Angul
Chattisgarh
Bilaspur
Cuttak
Orisaa
Bhubaneswar
Raipur
Bhilai
Mandsaur
Madhya Pradesh
Gujarat
Maharashtra
Nagpur
Belgaum
Karnataka
Andhra
Pradesh
Udipi
Bangaluru
Anantapur
Kadapa
Chennai
Mangalore
Palakkad
Tamil Nadu
Kerala
Thiruvananthapuram
Patna
Agartala
Hyderabad
Vizag
Rajahmundry
Telangana
Bellary
Siliguri
Guwahati
Gorakhpur
Allahabad
Muzzafarpur
Gopalganj
Arunachal Pradesh
Ranchi
Jorhat
Sibsagar
Meghalaya
Bihar
Coimbatore
Karaikal
Trichy
Kamuthi
Tiruneveli
Manufacturing Plant
Corporate Office
Branch Office
Service Center
Solar Project Office
Registered Office
B - 52, Corporate House, Judges Bunglow Road, Bodakdev, Ahmedabad - 380 054. Gujarat. India.
Phone: +91-79-6604 6200, Fax: +91-79-6604 6201
e-gallery
Sanand Works
SM 3 & 4, Sanand - II GIDC, Industrial Estate, Bol Village, Sanand - 382 110 Gujarat, India.
Phone: +91-2717-678777, Fax: +91-2717-678700
Email: contact@hitachi-hirel.com, Web: www.hitachi-hirel.com
In the spirit of continuous improvement, specifications are subject to change without notice.
facebook.com/hitachihirel
lnked.in/hitachihirel
Ver.1.0/2017/Solar/India l Spotlight
Hitachi Hi-Rel Power Electronics Pvt. Ltd.
MODbus
Input / Output Connection
Configuration
1. Standalone UPS
2. Standalone with inbuilt
isolation transformer
3. HSB mode with individual
battery bank
4. In-built battery
AC Input
Output Receptacle
Communication Connection
RS-485 port
Golden finger
3 Address switch
4 Communication setting
1
2
USB Port
RS-232 Port
Intelligent Slot
SNMP
Control Panel
Remaining
Backup Time Info
Fault Info
Mute Operation
Input & Battery
Voltage Info
Output & Battery
Voltage Info
AS-400
Remote shutdown
IP11 UPS is a true on-line UPS with microprocessor controller that delivers
continuous, high-quality AC power to connected equipment with no
interruption when transferring to battery.
Battery Info
Load Info
IP11 UPS provides protection from blackouts, brownouts, sags, surges or
noise interference and provides reliable and stable power.
IP11 UPS is a full feature transformer free UPS designed to offer compact,
efficient and reliable solutions to modern electronic gadgets. It features true
double conversion on line back up power solution for small data centres,
data networks, voice networks and process automation equipments.
IP11 UPS provides customers with a reliable source of uninterruptible
power even in harsh power environment, including very wide input
voltage/frequency window, better output voltage regulation, frequency
regulation, internal bypass, and input power factor correction and low THDi.
Mode Operation
Info
Connections
IP11 UPS has built-in RS-232 and bundled monitoring software. This online
UPS offers enhanced performance for power monitoring.
Advantages
¡
¡
¡
¡
¡
¡
¡
¡
¡
02
Easy to install and operate
Compact footprint
Robust and reliable connectivity
LCD interface
UPS can be configured with or without battery
UPS can be configured to ECO mode
Designed to operate in challenging electrical environment
Low EMI emission compliant for commercial installation
Large input voltage window
1
AC input
2
Input circuit breaker
3
USB communication port
4
RS-232 communication port
5
SNMP intelligent slot
6
External battery connection
(only available for L model)
iP11-1 kVA
iP11-2 kVA
iP11-3 kVA
7
Output receptacles
8
Output circuit breaker
9
Output terminal
03
Technical Specifications
Model
Phase
Capacity
Input
Nominal Voltage
IP11S-1/IP11H-1
IP11S-2/IP11H-2
Single Phase with Ground
IP11S-3/IP11H-3
1000 VA / 800 W
2000 VA / 1600 W
3000 VA / 2400 W
100 / 110 / 115 / 120 / 127 VAC or 200 / 208 / 220 / 230 / 240 VAC
55 - 150 VAC or 110 - 300 VAC (Based on Load at 50%)
85 - 140 VAC or 160 - 280 VAC (Based on Load at 100%)
Input Voltage Range
Frequency Range
Power Factor
Output
Output Voltage
Voltage Regulation
Frequency Range (Synchronized Range)
Frequency Range (Batt. Mode)
100 / 110 / 115 / 120 / 127 VAC or 200 / 208 / 220 / 230 / 240 VAC
± 1%
47~ 53 Hz or 57 ~ 63 Hz
50 Hz ± 0.25 Hz or 60 Hz ± 0.3 Hz
Current Crest Ratio
3:1
Harmonic Distortion
≤ 3 % THD (Linear Load)
≤ 6 % THD (Non-Linear Load)
Indicators
LCD
Alarm
Battery Mode
Low Battery
Overload
Fault
Physical
Long-run
Model**
Zero
4 ms (Typical)
AC Mode to Battery Model
Inverter to Bypass
Waveform (Batt. Mode)
Efficiency
AC Mode (Overall)
Battery Mode (Inverter)
Battery
Battery Type
Numbers
Standard
Typical Recharge Time
Model
Charging Current (max.)
Charging Voltage
Battery Type
Numbers
Long-run
Model*
Charging Current (max.)
Charging Voltage
Standard
Model
1. Standalone UPS
2. Standalone with inbuilt
isolation transformer
3. HSB mode with individual
battery bank
4. In-built battery
40 Hz ~ 70 Hz
≥ 0.99 @ Nominal Voltage (100% Load)
Ambient Temp <30°C
105% - 110% UPS Shut Down After 10 min. at Battery Mode or Transfer to Bypass When Utility is Normal
110% - 130% UPS Shut Down After 1 min. at Battery Mode or Transfer to Bypass When Utility is Normal
>130% UPS Shut Down After 3 sec. at Battery Mode or Transfer to Bypass When Utility is Normal
Overload
Transfer
Time
Configuration
Pure Sinewave
88%
83%
88%
87%
HS11 UPS is a true on-line UPS with microprocessor controller that delivers
continuous, high-quality AC power to connected equipment with no
interruption when transferring to battery.
90%
88%
HS11 UPS provides protection from blackouts, brownouts, sags, surges or
noise interference and provides reliable and stable power.
12 V / 7 AH
3
6
4 Hours Recover to 90% Capacity
HS11 UPS is a full feature transformer free UPS designed to offer compact,
efficient and reliable solutions to modern electronic gadgets. It features true
double conversion on line back up power solution for small data centres,
data networks, voice networks and process automation equipments.
1A
41.0 VDC ± 1%
3
41.0 VDC ± 1%
82.1 VDC ±1%
Depending on the Capacity of External Batteries
6
8
1A / 2A / 4A / 6A (Adjustable)
6
8
82.1 VDC ±1% 109.4 VDC ±1% 82.1 VDC ±1% 109.4 VDC ±1%
Load Level, Battery Level, AC Mode, Battery Mode, Bypass Mode and Fault Indicators
HS11 UPS has built-in RS-232 and bundled monitoring software. This
online UPS offers enhanced performance for power monitoring.
Sounding Every 4 Seconds
Sounding Every Second
Sounding Twice Every Second
Continously Sounding
Dimensions (WxDxH) (mm)
Net Weight (kgs)
Dimensions (WxDxH) (mm)
Net Weight (kgs)
Environment
Humidity
Noise Level
Management
Smart RS-232/USB
Optional SNMP
397 x 145 x 220
13
397 x 145 x 220
7
Advantages
419 x 190 x 318
30.5
28
419 x 190 x 318
26
13
HS11 UPS provides customers with a reliable source of uninterruptible
power even in harsh power environment, including very wide input
voltage/frequency window, better output voltage regulation, frequency
regulation, internal bypass, and input power factor correction and low THDi.
33
13
20 - 90 % RH @ 0 - 40°C (Non-Condensing)
Less than 50dBA @ 1 meter
Supports Windows 2000 / 2003 / XP / Vista / 2008 / 7 / 8, Linux, Unix and MAC
Power Management from SNMP Manager and Web Browser
¡
¡
¡
¡
¡
¡
¡
¡
¡
¡
Easy to install and operate
Compact footprint
Robust and reliable connectivity
LCD interface
UPS can be configured with or without battery
UPS can be configured to ECO mode
Designed to operate in challenging electrical environment
Low EMI emission compliant for commercial installation
Large input voltage window
Available in variable DC link in 6-10 kVA UPS for extend
battery backup
* 1 - 3 kVA: Derate to 80% of capacity in frequency converter mode and to 80% when the output voltage is adjusted to 100 / 200 / 208 VAC
** Long-run model is only available in 200 / 208 / 220 / 230 / 240 VAC systems (200 VAC system only available for 1-3 kVA)
* Product specifications are subject to change without further notice
04
05
Technical Specifications
Input / Output Connection
MODbus
Model
Phase
Capacity
Input
Nominal Voltage
Input Voltage Range
Input Neutral
Frequency Range
Input Line
Power Factor
Output
Output Voltage
Voltage Regulation
Frequency Range (Synchronized Range)
Frequency Range (Batt. Mode)
Output Line
Output Neutral
Ground
RS-485 port
Golden finger
3 Address switch
4 Communication setting
1
Communication Connection
2
HS11S-6 / HS11H-6
HS11S-10 / HS11H-10
Single Phase with Ground
6000 VA / 4800 W
10000 VA / 8000 W
200 / 208 / 220 / 230 / 240 VAC
176 - 280 VAC (Based on Load at 100%)
46 Hz ~ 54 Hz @ 50 Hz System
56 Hz ~ 64 Hz @ 60 Hz System
≥ 0.99 @ Nominal Voltage (100% Load)
200 / 208 / 220 / 230 / 240 VAC
± 1%
47~ 53 Hz or 57 ~ 63 Hz
50 Hz ± 0.25 Hz or 60 Hz ± 0.3 Hz
100% - 110% 10 min.
110% - 130% 1 min.
>130% 1 sec
Overload
USB Port
RS-232 Port
3:1 Max
Current Crest Ratio
Intelligent Slot
≤ 3 % THD (Linear Load)
≤ 6 % THD (Non-Linear Load)
Harmonic Distortion
Transfer
Time
SNMP
Control Panel
Remaining
Backup Time Info
Fault Info
Mute Operation
Input & Battery
Voltage Info
Output & Battery
Voltage Info
AS-400
Remote shutdown
Battery Info
Load Info
Mode Operation
Info
Connections
1
1
External battery connector
2
RS-232 communication port
3
Intelligent slot
4
USB communication
5
Emergency power off function connector
3
4
5
(EPO connector)
6
7
10 11 12
9
8
HS11- 6/10 kVA
06
Waveform (Batt. Mode)
Efficiency
AC Mode (Overall)
Battery Mode (Inverter)
Battery
Battery Type
Numbers
Standard
Typical Recharge Time
Model
Charging Current (max.)
Charging Voltage
Battery Type
Numbers
Long-run
Model*
Charging Current (max.)
Charging Voltage
6
Cooling fan
7
Input circuit breaker
8
Input/Output terminal
9
Maintenance bypass switch
10
Output terminal
11
Grounding terminal
12
Utility input terminal
0 ms.
0 ms.
Pure Sinewave
88%
83%
88%
87%
12 V / 7 AH
6
9 Hours Recover to 90% Capacity
1A ± 10%
218.4 VDC ± 1%
Depending on the Capacity of External Batteries
16 - 20
1A / 2A / 4A / 6A (Adjustable)
218.4 - 272 VDC ±1%
Physical
Standard
Model
2
AC Mode to Battery Model
Inverter to Bypass
Long-run
Model**
Dimensions (WxDxH) (mm)
Net Weight (kgs)
Dimensions (WxDxH) (mm)
Net Weight (kgs)
369 x 190 x 688
72
442 x 190 x 688
82
369 x 190 x 318
21
442 x 190 x 318
23
Environment
Operation Temp
Operation Humidity
Noise Level
Management
Smart RS-232/USB
Optional SNMP
0 - 40°C
(Battery Life Cycle will be Shorten When Temperature is Above 25°C
<95 and Condensing
Less than 55 dB @ 1 meter
Less than 58 dB @ 1 meter
Supports Windows 2000 / 2003 / XP / Vista / 2008 / 7 / 8, Linux, Unix and MAC
Power Management from SNMP Manager and Web Browser
* Derate to 80% of capacity in frequency converter mode and to 90% when the output voltage is adjusted to 208 VAC.
** If the UPS is installed or used in place where the altitude is above than 1000m, the output power must be derated one percent per 100m.
* Product specifications are subject to change without further notice.