Operating Instructions Air Conditioner

Operating Instructions
Air Conditioner
ENGLISH
2~5
Before operating the unit, read these operating instructions thoroughly and
keep them for future reference.
FRANÇAIS
* Shows 2WAY (Type ME2)
Model No.
OUTDOOR UNIT
2WAY (Type ME2 )
U-8ME2E8
U-10ME2E8
U-12ME2E8
U-14ME2E8
U-16ME2E8
U-18ME2E8
U-20ME2E8
● Connectable
6~9
Avant d’utiliser l’appareil, lisez ce mode d’emploi dans son intégralité et
conservez-le pour toute référence ultérieure.
This booklet is the operating instructions
for outdoor unit. Regarding the indoor
unit, see the operating instructions
supplied with the indoor unit.
INDOOR UNIT
1-Way Cassette
2-Way Cassette
4-Way Cassette
4-Way Cassette 60 × 60
Wall-Mounted
Ceiling
Low Silhouette Ducted
Slim Low Static Ducted
High Static Pressure Ducted
Floor Standing
Concealed Floor Standing
ESPAÑOL
10 ~13
DEUTSCH
14 ~ 17
Antes de operar la unidad, lea atentamente estas instrucciones de
funcionamiento y guárdelas para futuras consultas.
ITALIANO
18 ~ 21
NEDERLANDS
22 ~ 25
PORTUGUÊS
26 ~ 29
EΛΛΗΝΙΚΆ
30 ~ 33
БЪЛГАРСКИ
34 ~ 37
Antes de utilizar o aparelho, leia completamente este manual de instruções
e guarde-o para futuras referências.
Πριν θέσετε τη μονάδα σε λειτουργία, διαβάστε πολύ καλά αυτές τις οδηγίες
χρήσης και διατηρήστε τις για μελλοντική αναφορά.
Преди да започнете експлоатация на този уред, прочетете внимателно
тези инструкции и ги запазете, за да можете да правите справки с тях и
в бъдеще.
TÜRKÇE
38 ~ 41
РУССКИЙ
42 ~ 45
Üniteyi çalıştırmadan önce bu çalıştırma talimatlarını iyice okuyun ve
gelecekte başvurmak için saklayın.
AMP Air Conditioning
00_281202_all.indb 1
D
EUTSCH
I
N
EDERLANDS
P
ORTUGUÊS
E
ΛΛΗΝΙΚΆ
Б
ЪЛГАРСКИ
T
ÜRKÇE
Перед использованием этого устройства внимательно прочитайте
настоящую инструкцию по эксплуатации и сохраните ее для
дальнейших справок.
Р
УССКИЙ
46 ~ 49
Panasonic Corporation
1006 Kadoma, Kadoma City, Osaka, Japan
E
TALIANO
Lees deze gebruiksinstructies goed door voor u het apparaat gebruikt en
bewaar ze voor toekomstig gebruik.
Уважно прочитайте цю інструкцію з експлуатації перед тим, як
увімкнути пристрій, та збережіть її на майбутнє.
F
SPAÑOL
Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte diese
Bedienungsanleitung aufmerksam durch und bewahren Sie sie für die
künftige Verwendung auf.
УКРАЇНСЬКА
NGLISH
RANÇAIS
Prima di utilizzare l’unità, leggere a fondo queste istruzioni per l’uso e
conservarle come riferimento futuro.
indoor unit lineup
E
У
КРАЇНСЬКА
ACXF55-03680
www.ampair.co.uk | sales@ampair.co.uk
2016-6-28 9:29:47
Thank you for purchasing this Panasonic product.
This product is a commercial air conditioner outdoor unit.
Installation Instructions attached.
Contents
Safety Precautions............................................................ 2
zz
Precautions for Use.......................................................... 4
zz
Names of Parts.................................................................. 5
zz
Specifications.................................................................. 50
zz
•Outdoor unit.................................................................. 50
•Corresponding language table.................................... 51
Product Information
If you have problems or questions
concerning your Air Conditioner, you will
need the following information. Model and
serial numbers are on the nameplate.
Model No.
Serial No.
Date of purchase
Dealer’s address
Phone number
Safety Precautions
The following symbols used in this
manual, alert you to potentially dangerous
conditions to users, service personnel or
the appliance:
This symbol refers to
a hazard or unsafe
WARNING practice which can result
in severe personal injury
or death.
This symbol refers to
a hazard or unsafe
which can
CAUTION practice
result in personal injury
or product or property
damage.
Prohibited
matters
2
Matters to be
observed
•Read these Operating Instructions
carefully before using this air conditioner. If
you still have any difficulties or problems,
consult your dealer for help.
•This air conditioner is designed to give
you comfortable room conditions. Use this
only for its intended purpose as described
in these Operating Instructions.
AMP Air Conditioning
00_281202_all.indb 2
WARNING
Confirm to authorized dealer
or specialist on usage of
specified refrigerant type. Using
of refrigerant other than the
specified type may cause product
damage, burst and injury etc.
This air conditioner has no
ventilator for intaking fresh air
from outdoors. You must open
doors or windows frequently
when you use gas or oil heating
appliances in the same room,
which consume a lot of oxygen
from the air.
Otherwise there is a risk of
suffocation in an extreme case.
Never use or store gasoline or
other flammable vapor or liquid
near the air conditioner — it is
very dangerous.
Do not use this appliance in a
potentially explosive atmosphere.
Never touch the unit with wet hands.
Do not insert your fingers or
other objects into the air
conditioner indoor or
outdoor unit, rotating parts may
cause injury.
If the refrigerant comes in contact
with a flame, it produces a toxic
gas.
For safety, be sure to turn the
air conditioner off and also to
disconnect the power before
cleaning or servicing.
Pull off the power plug from
a receptacle, or switch off
the breaker, or switch off the
power disconnecting mean to
isolate the air conditioner from the
main power supply in case of
emergency.
Do not clean inside the indoor and
outdoor units by users. Engage
authorized dealer or specialist for
cleaning.
In case of malfunction of this
appliance, do not repair by yourself.
Contact to the sales dealer or
service dealer for a repair.
www.ampair.co.uk | sales@ampair.co.uk
2016-6-28 9:29:48
CAUTION
Provide a power outlet to be used
exclusively for each unit, and a
power supply disconnect, Earth
Leakage Circuit Breaker (ELCB)
or Residual Current Device (RCD)
for overcurrent protection should
be provided in the exclusive line.
Provide a power outlet
exclusively for each unit, and full
disconnection means having a
contact separation in all poles
must be incorporated in the fixed
wiring in accordance with the
wiring rules.
To prevent possible hazards
from insulation failure, the
unit must be grounded.
Do not use modified
cord, joint cord,
extension cord or
unspecified cord to prevent
overheating and fire.
Stop using the product when any
abnormality/failure occurs and
disconnect the power plug or turn
off the power switch and breaker.
(Risk of smoke/fire/electric shock)
Examples of abnormality/failure:
•The ELCB trips frequently.
•The product sometimes does not
start when turned on.
•The power is sometimes
disconnected when the cord is
moved.
•Burnt odor or abnormal noise is
detected during operation.
•The body is deformed or
abnormally hot.
•Water leaks from the indoor unit.
•Power cord or plug becomes
abnormally hot.
•Fan speed cannot be controlled.
•The unit stops running
immediately even if it is switched
on for operation.
•The fan does not stop even if the
operation is stopped.
Contact immediately your local
dealer for maintenance/repair.
AMP Air Conditioning
00_281202_all.indb 3
This appliance is intended to be used
by expert or trained users in shops,
in light industry and on farms, or for
commercial use by lay persons.
This appliance can be used by
children aged from 8 years and
above and persons with reduced
physical, sensory or mental
capabilities or lack of experience and
knowledge if they have been given
supervision or instruction concerning E
use of the appliance in a safe
way and understand the hazards
involved.
Keep the fire alarm and the air outlet
at least 1.5m away from the unit.
Do not cool or heat the room too
much if babies or invalids are
present.
Do not turn the air conditioner on
and off from the power mains switch.
Use the ON/OFF operation button.
Do not stick anything into the air
outlet of the outdoor unit. This
is dangerous because the fan
is rotating at high speed.
Do not touch the air inlet or
the sharp aluminum fins of
the outdoor unit. You may get
injured.
Do not sit or step on the unit.
You may fall down accidentally.
NGLISH
Do not stick any object
into the FAN CASE. You
may be injured and the
unit may be damaged.
NOTICE
•The compressor may occasionally stop during thunderstorms.
This is not a mechanical failure. The unit automatically
recovers after a few minutes.
•The English text is the original instructions. Other languages
are translations of the original instructions.
Important Information Regarding
The Refrigerant Used
This product contains fluorinated greenhouse gases covered
by the Kyoto Protocol. Do not vent gases into the atmosphere.
Refrigerant type: R410A
GWP(1) value: 1975
(1)
GWP = global warming potential
Periodical inspections for refrigerant leaks may be required
depending on European or local legislation. Please contact
your local dealer for more information.
3
www.ampair.co.uk | sales@ampair.co.uk
2016-6-28 9:29:49
Precautions for Use
Installation
Operation Condition
This air conditioner must be installed properly by qualified
zz
installation technicians in accordance with the Installation
Instructions provided with the unit.
Before installation, check that the voltage of the electric supzz
ply in your home or office is the same as the voltage shown
on the nameplate.
Use this air conditioner under the following temperature range.
WARNING
Avoid the following locations for installation.
Locations where smoke or combustible gas exists.
zz
Also locations of extremely high temperature such as a
greenhouse.
Locations where excessively high heat-generating obzz
jects are placed.
Outdoor
temperature
range
2WAY (Type ME2)
-10°C
Cooling
14°C
25°C (*WBT)
Heating
16°C
30°C (*DBT) -25°C
52°C (*DBT)
-10°C 43°C (*DBT)*1
18°C (*WBT)
*DBT: Dry bulb temperature
*WBT: Wet bulb temperature
*1:The maximum allowable temperature of this air conditioning
system is reduced to 43°C when using the existing R22 pipe.
Information for Users on Collection and Disposal of
Old Equipment and Used Batteries
Attention:
These symbols on the products, packaging, and/
or accompanying documents mean that used
electrical and electronic products and batteries
should not be mixed with general household waste.
For proper treatment, recovery and recycling of
old products and used batteries, please take them
to applicable collection points, in accordance
with your national legislation and the Directives
2002/96/EC and 2006/66/EC.
By disposing of these products and batteries
correctly, you will help to save valuable resources
and prevent any potential negative effects on
human health and the environment which could
otherwise arise from inappropriate waste handling.
For more information about collection and recycling
of old products and batteries, please contact your
local municipality, your waste disposal service or
the point of sale where you purchased the items.
Penalties may be applicable for incorrect disposal
of this waste, in accordance with national
legislation.
Avoid installing the outdoor unit where salty sea water can
zz
splash directly onto it or in sulphurous air near a spa.
(To protect the air conditioner from heavy corrosion)
Wiring
All wiring must conform to the local electrical codes.
zz
(Consult your dealer or a qualified electrician for details.)
Each unit must be properly grounded with a ground (or
zz
earth) wire or through the supply wiring.
Wiring must be done by a qualified electrician.
zz
Operation Preparation
Turn the power mains on 5 hours before
the start of operation.
Indoor
temperature
range
Outdoor Unit
ON
(For warm-up)
Leave the power mains ON for continuous use.
zz
For business users in the European Union
If you wish to discard electrical and electronic
equipment, please contact your dealer or supplier
for further information.
NOTE
Pull off the power plug from a receptacle, or switch off the
breaker, or switch off the power disconnecting mean to isolate
the air conditioner from the main power supply when not in use
for a long time.
[Information on Disposal in other Countries
outside the European Union]
These symbols are only valid in the European
Union. If you wish to discard these items, please
contact your local authorities or dealer and ask for
the correct method of disposal.
Pb
Note for the battery symbol (bottom two
symbol examples):
This symbol might be used in combination with
a chemical symbol. In this case it complies with
the requirement set by the Directive for the
chemical involved.
4
AMP Air Conditioning
00_281202_all.indb 4
www.ampair.co.uk | sales@ampair.co.uk
2016-6-28 9:29:50
Names of Parts
OUTDOOR UNIT
2WAY (Type ME2)
8,10 HP
12,14,16 HP
18,20 HP
Air outlet
E
NGLISH
Air intake
Air intake
Air intake
Drain port
(bottom)
Optional
Wireless Remote Controller
Timer Remote Controller
For all indoor units
Model No.
CZ-RTC4
A
High-spec Wired Remote Controller
Model No. CZ-RTC5A
For all indoor units
For all indoor
units
Read the Operating Instructions included with the Remote Controller.
 Adjusting Airflow Direction
Refer to the Operating Instructions attached to the indoor unit.
 Maintenance
Refer to the Operating Instructions attached to the indoor unit.
 Troubleshooting
Refer to the Operating Instructions attached to the indoor unit.
5
AMP Air Conditioning
00_281202_all.indb 5
www.ampair.co.uk | sales@ampair.co.uk
2016-6-28 9:29:53
Panasonic Corporation
Website: http://www.panasonic.com
© Panasonic Corporation 2016
Printed in Malaysia
AMP Air Conditioning
00_281202_all.indb 56
Authorised representative in EU
Panasonic Testing Centre
Panasonic Marketing Europe GmbH
Winsbergring 15, 22525 Hamburg, Germany
ACXF55-03680
DC0716-0
www.ampair.co.uk | sales@ampair.co.uk
2016-6-28 9:30:52
Download PDF