MODEL
8505
Withstand Voltage & Insulation Tester
Instruction Manual
I-02271
FOR SAFE USE
For safe use of this tester, please observe the following warning and caution.
!
Regarding safety symbols
In order to help the users to use the testers safely, the following symbols are used in this manual.
 、
Place where there is a dangerous high voltage.
! Warning
It shows the content that a dangerous situation is possible which may cause a fatal accident or
severe injury in case the tester is mishandled.
! Caution
It shows the content that a dangerous situation is possible which may cause a minor injury to user
or only material damage in case the tester is mishandled.
! Warning
●This tester is designed to output a high voltage. As there is a danger
hock, please follow the directions below:
of an electric s
・Do not touch output terminal, high voltage cables or test samples during the test.
The places marked withon the tester are the dangerous parts where the high voltage is generated.
・Make sure to connect the protective ground terminal to the earth.
・Do not short-circuit the output to the ground or commercial power supply line. It is dangerous as the housing of
the tester is charged with high voltage. It also causes the breakdown of the tester.
・When operating the tester, put on the rubber gloves of an electric operation purpose.
・For the connection to the test specimen, use the enclosed high-voltage cable or an electric cable that confirms to
the operating voltage.
●Place for installation
・Never use or install this tester in the place where explosive or flammable materials as mentioned below are used
or stored. (Occupational Safety and Health Act, Enforcement Regulations Appendix Table 1 Hazardous
Materials )
[Explosive materials], [Ignitable materials], [Inflammable materials], [Flammable gas], [Oxidizing materials]
※This tester uses metal internally. There is a risk of deterioration due to the occurrence of corrosion or rust and
explosion or ignition by an electric spark.
・Do not place objects on top of this tester or use it as a footstool.
※It affects the heat dissipation causing internal temperature rise and break-down.
※There is a risk that the upper part is deformed.
●Storage
・Take care that the water drops like from rain do not wet the tester.
※There is a risk of electric shock or malfunction.
・Do not place the tester sideways. Take care during handling and do not let it fall down due to the vibration etc.
※There is a risk of damage of internal mechanism or malfunction.
!Caution
●Do not use the tester in the following places
Followings can cause the trouble due to break-down or malfunction.

Rain, water drops or direct sunlight places.

Places having high temperature, high humidity , dust and corrosive gas.

Places having external noise, radio waves or static electricity.

Places which are unstable or having lot of mechanical vibrations or shock.

Places where high sensitivity measuring testers or receivers are located nearby.
・Do not open the case or modify the tester as it may cause a danger of an electric shock or other troubles.
・If the operation is abnormal, turn off the power supply switch immediately and unplug the power cord.
・Make sure to stop the use and turn off the power supply during the maintenance or checking.
・Do not use the tester where the ventilation is poor.
Cooling system of this tester is forced air cooling from
the rear panel. Mainly it takes in the air from the bottom
Exhaust exit
and discharge to the rear side. As heat may be trapped
and become the reason for the fire, always keep space of
more than 10cms between the top, side, rear and the
walls. In between the bottom surface and the floor (the
height of rubber foot is about 14mm), do not place any
object like paper, plastic etc. which can be easily sucked
in.
Suction inlet
Front panel
●Apply the voltage to capacitance load (test sample)
The output voltage may rise higher than the case of no load depending upon the capacitance value of the load.
Also, in case of voltage dependent load (test sample), the waveform distortion may occur.
In case of test voltage 2kV, the influence of capacitance less than 2000pF can be ignored.
●Transportation
・Hold the chassis (bottom plate) during transportation.
Do not carry the tester holding its red bushing of high voltage terminal section (refer to ⑩ of “1. Part
names and functions”).
※The bushing (red) may get damaged and there is a risk of serious injury when this product falls down.
・Minimize the mechanical vibration or shock when transporting the tester.
※There is a risk of damage of internal mechanism or malfunction.
●Regarding Interlock
This tester is provided with interlock function.
No test can be made when interlock function is in operation.
The interlock function can be released by plugging the enclosed remote /out plug into the remote I/O
connector ⑤ and pressing the stop switch ⑫.
Content
Preface ........................................................................................................................... 1
Functions ........................................................................................................................................ 1
Confirmation prior to use ............................................................................................. 2
Inspection at the time of unpacking .................................................................................................. 2
Cautions for handling ...................................................................................................................... 2
1.Names and functions of each part ........................................................................... 3
Front Panel ..................................................................................................................................... 4
Rear Panel....................................................................................................................................... 7
2.Preparation before use ............................................................................................. 9
Connection of power cord.............................................................................................................. 10
Connection of the protective earth terminal .................................................................................... 10
Method of removing and mounting of key cover (option) ............................................................... 10
Connection to the external control equipment ................................................................................. 11
Connection of the high-voltage cable ............................................................................................. 11
Power on and off ........................................................................................................................... 12
3.Panel operation ...................................................................................................... 13
Expression of the panel display of setting operation........................................................................ 14
Key Lock ...................................................................................................................................... 14
Configuration of the display .......................................................................................................... 15
Setting of test conditions ............................................................................................................... 15
READY state ................................................................................................................................ 16
Display during the test ................................................................................................................... 17
Display example of judgment result ............................................................................................... 17
4.Setting of a single test and an automatic test (ACW→IR, IR→ACW) .................... 19
Types of test .................................................................................................................................. 20
Selection of test mode ................................................................................................................... 21
5.Setting of withstand voltage test conditions .......................................................... 23
Setting of test voltage .................................................................................................................... 24
Upper limit judgment value ........................................................................................................... 25
Lower limit judgment value ........................................................................................................... 26
Setting of the voltage rise time (rise time) ...................................................................................... 27
Setting of the voltage fall time (fall time) ....................................................................................... 28
Setting of the test time ................................................................................................................... 29
Setting of test voltage frequency .................................................................................................... 30
6.Setting of insulation resistance test (IR) conditions ............................................... 31
Setting of test voltage .................................................................................................................... 32
Setting of resistance range ............................................................................................................. 32
Upper limit judgment and lower limit judgment value .................................................................... 34
Setting of mask time...................................................................................................................... 34
Setting of test time ........................................................................................................................ 35
7.Memory operation ................................................................................................. 37
Overview ...................................................................................................................................... 38
Call and setting of memory ............................................................................................................ 39
8.Program operation ................................................................................................. 41
Overview ...................................................................................................................................... 42
Flow of program operation ............................................................................................................ 43
Call of program operation .............................................................................................................. 44
Setting of the program ................................................................................................................... 45
9.Test method (From the start of the test till the judgment) .......................................... 47
Method operation of single withstand voltage test........................................................................... 48
Operation method of single insulation resistance test ...................................................................... 49
Operation method of automatic test ................................................................................................ 50
Operation method of program operation test ................................................................................... 51
10.Other functions .................................................................................................... 53
Double action start ........................................................................................................................ 54
GOOD hold .................................................................................................................................. 54
Momentary start ............................................................................................................................ 54
FAIL mode .................................................................................................................................... 54
NG start ........................................................................................................................................ 54
Setting method .............................................................................................................................. 55
Setting of the buzzer ...................................................................................................................... 56
Interlock ....................................................................................................................................... 57
11.Remote I/O.......................................................................................................... 59
Overview of the test depending on remote I/O ................................................................................ 60
From the test conditions setting of remote I/O to test start ............................................................... 61
Connector pin array and pin function ............................................................................................. 62
Interlock signal ............................................................................................................................. 63
Protective function operation (PROTECTION) .......................................................................... 63
Input signal ................................................................................................................................... 64
Output signal and the control power supply .................................................................................... 65
Timing chart.................................................................................................................................. 66
12.PC remote control................................................................................................ 67
RS-232C・USB Interface ............................................................................................................... 68
13.Error message ...................................................................................................... 69
Error display ................................................................................................................................. 70
Coping with error display .............................................................................................................. 70
14.Maintenance ........................................................................................................ 71
Cleaning ....................................................................................................................................... 72
Problem solving ............................................................................................................................ 72
Calibration .................................................................................................................................... 72
15.Specifications ....................................................................................................... 73
Withstand voltage test ................................................................................................................... 74
Insulation resistance test ................................................................................................................ 76
Memory operation ......................................................................................................................... 77
Program operation ......................................................................................................................... 77
Other functions ............................................................................................................................. 78
Input Output signal........................................................................................................................ 78
RS-232C・USB Interface ............................................................................................................... 79
General specification ..................................................................................................................... 80
Setting of the default value ............................................................................................................ 80
Dimensions ................................................................................................................................... 82
MEMO ......................................................................................................................................... 83
This page is blank.
Preface
For proper use of this tester, read these instructions carefully before initial operation. Make sure that
this instruction manual is available to the responsible person for the operation. Besides, keep this
manual near the tester so that the operator can read it any time.
Functions
As this tester handles the high voltage, so it is designed with a lot of protective functions and a number
of considerations for the safety of the users.
・The withstand voltage tester has the capability of maximum output of 5kV and output capacity of
100VA.
・Precise test can be made due to upper and lower limit leakage current setting.
・As the insulation tester, this model is provided with 6 ranges of DC25V~DC1000V.
・The displays of test voltage, current and test time are easy-to-read green large LED.
・16 sets of memory are equipped which can write and read the test conditions.
・16 sets of memory are equipped which can program 16 steps of applied voltage of withstand
voltage test and test time.
・It is possible to control input of the start/stop of the test from the outside by remote I/O connector.
Besides, matching with the status of this tester, the output signals like “waiting”, “under test” or
“decision result” etc. are output in open collector.
MODEL 8505
1
Confirmation prior to use
Inspection at the time of unpacking
(1)When unpacking
When the tester is delivered, check whether it has been damaged in transit and unpack it carefully.
In case the tester does not operate as per the specification due to damage, contact the dealer from
where you have purchased or sales office.
(2)Checking of the contents
Check the packing box which contains the main item and the standard accessories as listed below.
List of accessories
Instruction manual (Main document)
RS-232C・USB Interface manual
High voltage cable 2m
Earth wire
3m
Power supply cord 2.5m
Remote I/O plug
! Caution
1 set
1 set
1 pair
1 piece
1 piece
1 piece(36P)
・For external communication RS-232C(D sub 9 pin model 5881-11-018)
When the customer procures it, it is requested to use the inch pitch screw type.
USB cable (Standard A-B model 5881-12-010) is optional.
Cautions for handling
Since this tester deals with high voltage, it is designed paying special attention to the safety. However, it
is still dangerous as it outputs high voltage of max. 5kV. An erroneous handling may cause fatal
accident. In order to avoid any accident, strictly observe the following cautions and take utmost care for
safety.
! Warning
If the earthing is insufficient, there is a risk of electric shock.
(1)Make sure to connect the protective ground terminals (rear panel) to the earth. If the grounding
is insufficient and the output is short-circuited to the earth or power supply line, the tester
housing is charged with high voltage and it is very dangerous when the operator touches the
outer box.
Check if the earthing cable is disconnected or not.
(2)During the test, never touch the output terminals, high voltage cable and test samples.
(3)When making a connection to the test sample, with output OFF , connect the LOW side prior
to other.
(4)When operating this tester, put on rubber gloves for electric shock prevention.
MODEL 8505
2
1.Names and functions of each part
Front Panel ..................................................................................................................................... 4
Rear Panel ...................................................................................................................................... 7
MODEL 8505
3
1.Names and functions of each part
Front Panel
1
9
No.
1
2 3
10
7
mA
HIGH
MΩ
LOW
12
8
GOOD
GOOD
HIGH
HIGH
LOW
LOW
13
14
15 16
Function description
Gives warning lamp when the test voltage is an
output.
MEMORY No.
Memory operation, display of memory number and step number of program operation
Memory, Lit up during program operation , blinking during setting up
PROG Lamp
During program operation, Lit up during
setting
TEST VOLTAGE
Withstand voltage test :
Program operation :
Insulation test :
V, kV Lamp
Unit display of test voltage
FREQ Display
Display of the frequency setting of the test voltage in regards to withstand voltage test
CURRENT
/RESISTANCE
Withstand voltage test : Display of leakage current measurement value and result
value, blinking during setting up
Insulation test :
Display of insulation resistance measurement value and result
value, blinking during setting up
HIGH SET Lamp
Lights up when upper limit value is set
LOW SET Lamp
Lights up when lower limit value is set
TIME
RAISE Lamp
6
11
6
DANGER Lamp
3
5
5
Name
2
4
4
TEST Lamp
FALL Lamp
MASK Lamp
MODEL 8505
Lighting of each lamp, refer
blinking state
Lighting of each lamp, refer
blinking state
Display of setting of test voltage and value of output voltage.
Setting of step off (end) (withstand voltage test only)
Setting of the test voltage
Lighting of each lamp, refer
blinking state
Lighting of each lamp, refer
blinking state
Withstand voltage test : Display of RAISE、TEST、FALL time
Insulation test :
Display of MASK、TEST time
During withstand voltage test RAISE operation,
Lights up during setting
During withstand voltage test TEST operation,
Lights up during setting
Lighting of each lamp, refer
During withstand voltage test FALL operation, blinking state
Lights up during setting
During MASK time of insulation test, Lights up
during setting
4
No.
Name
JUDGE
Display of decision result and test status
ACW-TEST Lamp
Lights up during withstand voltage test
IR-TEST Lamp
Lights up during insulation test
GOOD Lamp
Lights up when the decision result of the test is passed
7
HIGH Lamp
LOW Lamp
MODE
ACW-IR Lamp
IR-ACW Lamp
ACW Lamp
8
Lighting of each lamp,
refer blinking state
Lights up when the decision result of the test is larger than the
upper limit decision value
Lights up when the decision result of the test is less than the
lower limit decision value
Display of test mode and operation mode
Withstand voltage test → Lights up in insulation test mode,
blinking during setting
Insulation test → Lights up in withstand voltage test mode,
blinking during setting
Lights up during withstand voltage test mode , blinking during
setting
IR Lamp
Lights up during insulation test mode, blinking during setting
READY Lamp
Lights up during READY status
REMOTE Lamp
Lights up during remote control status
KEYLOCK Lamp
Lights up during locked status of key operation setting
DISCHARGE Lamp
Blinking during the discharge of insulation test
MODEL 8505
1
Function description
5
Lighting of each lamp,
refer blinking state
1.Names and functions of each part
No.
Name
Function description
9
LOW terminal
Low-voltage side terminal of the test voltage output, the tester case and the same
potential
10
HIGH VOLTAGE terminal
High-voltage side terminal of the test voltage output, the output of the high voltage
during the test
11
Buzzer
Buzzer
12
START switch
Start switch of the test
13
STOP switch
Interruption and judgment return switch of the test
Setup
Key for reading and writing the setting of the test conditions such as test mode, test
voltage, upper and lower limit values, test time etc.
key

MEM

PROG
▼
SET
14
▲
Key to select each setting after entering the setup mode
Hold down the SHIFT and press the MEM key to switch to the memory operation
Key to select each setting after entering the setup mode
Hold down the SHIFT and press PROG key to switch to the program operation
Key to change each setting item
Hold down the SHIFT and press SET key for some time to switch to other function
setting
Key to change each setting item
RANGE
Hold down the SHIFT and press RANGE key while setting to switch to the decimal
point
REMOTE
LOCK
Key to set/release remote operation
ENTER
EXIT
Stores the set value and exits from the setting operation
SHIFT
Used in combination with other keys
Function that is displayed on the lower side of the key is enabled
Hold down the SHIFT and press LOCK key to switch to Key lock set/release
Hold down the SHIFT and press EXIT key to interrupt the setting operation and
READY state
15
POWER switch
Switch for the power
16
Key cover
Protect the set up key from being touched (option)
MODEL 8505
6
Rear Panel
1
1
AC LINE 200VA MAX
100-240V
50-60Hz
REMOTE I/O
注
意
CAUTION
RS-232C
USB
接 地端子は確実に
大 地アースしてください。
ENSURE GROUNDING OF
EARTH TERMINAL.
2
No.
1
3
4
Name
AC LINE connector
5
6
Function description
Supply power inlet
Protective earth terminal. Terminal for earthing the case of the tester with same
potential
2
3
RS-232C connector
RS-232C interface
4
USB connector
USB interface
5
Remote I/O connector
Connector for external control
6
Cooling fan
Fan for exhaust
MODEL 8505
7
1.Names and functions of each part
This page is blank.
MODEL 8505
8
2.Preparation before use
Connection of power cord ............................................................................................................. 10
Connection of the protective earth terminal .................................................................................... 10
Method of removing and mounting of key cover (option) ............................................................... 10
Connection to the external control equipment..................................................................................11
Connection of the high-voltage cable ..............................................................................................11
Power on and off ........................................................................................................................... 12
MODEL 8505
9
2.Preparation before use
Connection of power cord
1
2
3
! Warning
Make sure that the power switch POWER of this tester is turned off.
Connect the power cord to the inlet for the power supply of the rear face.
The plug of the power cord that comes with this tester is for AC100V. If it exceeds AC125V, use
the power cord suitable for the rating. 200V type power cord with a plug attached (European 2-pole
with earth model name 5880-23-030) is optional.
Power cord plug (3P) is connected to the earthed outlet.
The plug of the power cord is 3- pin and the round shaped pin of the center is the earthing.
Use supply voltage AC100~AC240V (AC90~250V) and power frequency 50/60Hz. Besides,
when you connect the power cord, make sure that the power switch is turned off. Beyond this
range could lead to the failure and incomplete operation of the tester.
Connection of the protective earth terminal
Earth the protective earth terminal ② to the ground using the supplied earthing wire. When the
earthing is imperfect or when the output is short circuited to the ground or power line, the case of the
tester is highly charged and it is dangerous to touch it. Besides, when using the tester, be sure to check
that the earthing wire is not disconnected.
! Warning
If the earthing is imperfect, there is a risk of an electric shock.
Method of removing and mounting of key cover (option)
You can mount the key cover (Model 5858-19) to the set up key as an option.
It is used when the set value is not wanted to be processed. As it is fixed with knurled screws, removing
and mounting can be done easily with your fingers.
MODEL 8505
10
Connection to the external control equipment
External control equipment can be connected to the remote I/O connector ⑤
2
Refer to “11.Remote I/O” for connection method.
Connection of the high-voltage cable
During the test, the high voltage output terminal is charged to a high voltage. Connect the supplied high
voltage cable with the HIGH VOLTAGE terminal and LOW terminal. For high voltage cable, use the
supplied cable or cable adaptable for the voltage used.
! Warning
・Make sure to confirm the power off before connecting the high voltage cable. There is
a risk of an electrical shock.
・As the vinyl covering part of alligator clip of the supplied high voltage cable is not a
withstand voltage, do not touch during the test. There is a risk of an electric shock.
After connecting the low-voltage side cable to the LOW terminal ⑨, be sure to secure the retaining
bracket to the terminal.
LOW TERMINAL ⑨
LOW VOLTAGE CABLE
(BLACK)
8505
MAIN
BODY
Retaining bracket
Tighten the low terminal of the main body with the U shaped groove side of the retaining bracket
! Warning
MODEL 8505
When the low voltage side cable is disconnected, the whole tested equipment gets charged with
high voltage and there is a risk of an electric shock.
11
2.Preparation before use
Power on and off
After purchasing for the first time when POWER switch⑮ is on, the test begins and due to interlock
function, the state becomes PROTECTION state. Connect the supplied remote I/O connector.
Use the supplied remote I/O connector only after the PROTECT state is released easily.
If you do the actual test, use the interlock function for the safety.
To guard the test area against the electric shock, use the interlock function like cut-off etc.
when opening the door or cover.
1
2
3
4
! Caution
MODEL 8505
Make sure that the power cord, connection cables etc. are connected properly.
Press “-” side of POWER switch ⑮ of front panel to turn it on.
After turning on the power switch, all lights on display are on for few seconds (lamp test).
However, TEST VOLTAGE and CURRENT/RESISTANCE display firm version.
After a few seconds, the display would be of test mode when the previous power was turned off.
Press “○” side of the POWER switch of the front panel to turn it off.
Do not turn off the POWER switch ⑮ during the test voltage output. This may cause a malfunction.
However, it excludes in the state of emergency stop when voltage output does not decrease even
when the STOP switch is pressed due to the abnormality of test sample etc.
12
3.Panel operation
Expression of the panel display of setting operation ....................................................................... 14
Key Lock ...................................................................................................................................... 14
Configuration of the display .......................................................................................................... 15
Setting of test conditions ............................................................................................................... 15
READY state ................................................................................................................................ 16
Display during the test................................................................................................................... 17
Display example of judgment result ............................................................................................... 17
MODEL 8505
13
3.Panel operation
Expression of the panel display of setting operation
Depending on the key operation, the state of the display unit LED is expressed as below:
Surface-emitting
LED Lamp
Numerical Indicator
Round LED
Lamp
On state
ACW-IR
Blinking state
ACW-IR
Off state
ACW-IR
! Caution
During setting, if key is not operated for about five minutes, it automatically returns to READY state.
During this time the contents changed will not be stored.
Key Lock
With this operation, the setting key operation is disabled.
At this time, only START switch and STOP switch are enabled in front panel operation.
mA
HIGH
1
3
Setting of Key Lock
① Press LOCK key (pressing the LOCK while holding down the SHIFT) for 3 seconds in the READY
state.
② KEY LOCK lamp is lit and the key lock function is set.
Release of Key Lock
MODEL 8505
③ Press LOCK key (pressing the LOCK while holding down the SHIFT) for 3 seconds till KEY
LOCK lamp is off.
14
Configuration of the display
The front panel display of this tester can be broadly divided into four parts. The setting of test
conditions can be done in accordance to the objectives like application of memory operation, program
operation and other functions.
3
Setting of test
conditions
Display of READY
state
Test mode selection and set each setting value
Memory operation (7. Memory operation)
Program operation (8. Program operation)
Other functions (9. Other functions)
Under Test
Judgment Result
Setting of test conditions
It shows the test mode that is currently selected.
Panel
display
Test Mode
ACW-IR
Withstand voltage test → Insulation test
IR-ACW
Insulation test → Withstand voltage test
ACW
Withstand voltage test
IR
Insulation test
Setting Method
For detail refer “4. Setting of independent test and automatic test”, “5. Setting of withstand voltage test
conditions” and “6.Setting of insulation test conditions”.
MODEL 8505
15
3.Panel operation
READY state
1) When the POWER switch ⑮ is turned on, after displaying firmware version for a few seconds,
READY lamp turns on and becomes READY state.
2) READY lamp is on in the state where the test can be started.
3) When setting the test conditions etc. READY lamp turns off.
4) In the automatic test mode (ACW-IR, IR-ACW), the test conditions setting of withstand voltage test
and insulation resistance test are displayed alternately.
mA
HIGH
Withstand voltage test
( ACW )
Display alternately (During ACW-IR, IR-ACW)
Insulation resistance test
MΩ
LOW
( IR )
Panel setting mode is
MODEL 8505
When MEMORY, PROG display are off, “Panel setting mode” is written.
16
Display during the test
During withstand voltage test,
DANGER lamp is turned on and test voltage value and leakage current value are displayed.
Withstand voltage test
( ACW )
Rise
Test
3
Fall
Test voltage
2.00kV
1.00kV
mA
HIGH
Display example
of elapsed time
0.0 15.0
45.0 60.0
Elapsed time (s)
During insulation resistance test,
DANGER lamp is turned on and test voltage range and insulation resistance value are displayed.
Insulation resistance test
( IR )
LOW
Display example of judgment result
Display example during automatic test (IR-ACW), when IR, ACW and GOOD
GOOD
mA
judgment are done.
GOOD
HIGH
Display example during automatic test (ACW_IR), when GOOD judgment in ACW and NG judgment in IR
are done.
GOOD
MΩ
MODEL 8505
17
LOW
LOW
LOW
3.Panel operation
This page is blank.
MODEL 8505
18
4.Setting of a single test and an automatic test
(ACW→IR, IR→ACW)
Types of test.................................................................................................................................. 20
Selection of test mode ................................................................................................................... 21
MODEL 8505
19
4.Setting of a single test and an automatic test
Types of test
This tester has a single test and an automatic test.
1)
Single test
・Withstand voltage test (ACW)
・Insulation resistance test (IR)
2)
Automatic test
The withstand voltage test and insulation resistance test are switched to each other automatically and
the test is carried out continuously.
・Switch to insulation resistance test from withstand voltage test (ACW-IR)
・Switch to withstand voltage test from insulation resistance test (IR-ACW)
MODEL 8505
20
Selection of test mode
1
mA
3
1
2
4
Enter in mode selection
① Press MODE key (

or

).
・Test mode lamp of MODE display blinks.
Selection of the test
② Selection is done by ▲
and
▼
keys.
Automatic test by the blinking of ACW-IR lamp from withstand voltage test to insulation resistance
test.
Automatic test by the blinking of IR-ACW lamp from insulation resistance test to withstand voltage
test.
Withstand voltage test by blinking of ACW lamp.
Insulation resistance test by blinking of IR lamp.
・Switching to the setting of test conditions by 
or

key.
End of the selection
③ Press ENTER key and the setting is stored and returns to the READY state.
Interruption of the selection
④ If EXIT key (Holding down SHIFT and press EXIT) is pressed, the operation is interrupted,
becomes READY state and the state is the one before entering the operation.
MODEL 8505
21
4
4.Setting of a single test and an automatic test
This page is blank.
MODEL 8505
22
5.Setting of withstand voltage test conditions
Setting of test voltage .................................................................................................................... 24
Upper limit judgment value ........................................................................................................... 25
Lower limit judgment value........................................................................................................... 26
Setting of the voltage rise time (rise time) ...................................................................................... 27
Setting of the voltage fall time (fall time) ....................................................................................... 28
Setting of the test time................................................................................................................... 29
Setting of test voltage frequency .................................................................................................... 30
MODEL 8505
23
5.Setting of withstand voltage test conditions
Setting of test voltage
Single test ACW、automatic test ACW-IR、and withstand voltage test conditions of IR-ACW are set.
Test voltage is set.
Setting range : 0.00kV~5.50kV
2
mA
1
HIGH
5
3
4
2
3
6
Enter in setting mode
① Select the test mode. ACW-IR、IR-ACW、ACW
② Press

or

key.
・ACW-TEST lamp of JUDGE display turns on.
Setting of test voltage
③ Press

key.
The number of TEST VOLTAGE display blinks.
④ Test voltage is set using
▲
and
▼
keys.
Switching of test conditions
・Switch to the other conditions using 
or

key.
End of setting
⑤ Press the ENTER key to store the settings and return to the READY state.
Interruption of setting
⑥ When EXIT key (Hold down SHIFT and EXIT) is pressed, the operation is interrupted, becomes
READY state and the state is the one before entering the operation.
Setting flow of withstand voltage test
Start of ACW flow
Withstand
voltage
test
ACW
MODEL 8505
Test
voltage
TEST
VOLTAGE
End of ACW flow
Upper limit
judgment
value
HIGH
SET
Lower limit
judgment
value
LOW
SET
Voltage
rise
time
RAISE
TIME
24
Voltage
fall
time
FALL
TIME
Test time
TEST
TIME
Test
voltage
frequency
TEST
FREQUENCY
Upper limit judgment value
Upper limit value of the judgment is set.
Setting range : 0.01~20.00mA
3
mA
2
1
HIGH
5
3
4
2
3
6
Enter in setting mode
① Select the test mode ACW-IR、IR-ACW、ACW
② Press

or

key.
・ACW-TEST lamp of JUDGE display is turned on.
Setting of upper limit judgment value
③ Press

or

key.
・The number of CURRENT display blinks and HIGH is turned on.
④ Upper limit judgment value is set by
▲
and
▼
or

keys.
Switching of test conditions
Switch to other setting conditions using

key.
End of the setting
⑤ Press the ENTER key to store the settings and return to the READY state.
Interruption of the setting
⑥ When EXIT key (Hold down SHIFT and EXIT) is pressed, the operation is interrupted, becomes
READY state and the state is the one before entering the operation.
Setting flow of withstand voltage test
Start of ACW flow
Withstand
voltage
test
ACW
MODEL 8505
Test
voltage
TEST
VOLTAGE
End of ACW flow
Upper limit
judgment
value
HIGH
SET
Lower limit
judgment
value
LOW
SET
Voltage
rise
time
RAISE
TIME
25
Voltage
fall
time
FALL
TIME
Test time
TEST
TIME
Test
voltage
frequency
TEST
FREQUENCY
5
5.Setting of withstand voltage test conditions
Lower limit judgment value
・Lower limit value of the judgment is set. It is turned off when setting is not required.
・Lower limit judgment is not performed during voltage rise and voltage fall.
・Setting range : 0.01~19.99mA and OFF
2
1
mA
5
LOW
3
4
2
3
6
Enter in setting mode
① Select the test mode. ACW、ACW-IR、IR-ACW
② Press

or

key.
・ACW-TEST lamp of JUDGE display is turned on.
Setting of lower limit judgment
③ Press

or

key.
・The number of CURRENT display blinks and LOW is turned on.
④ Setting of lower limit judgment value is done by ▲
Setting of OFF is done by pressing
▼
and
▼
keys.
key continuously.
Switching of test conditions
Switch to the other setting conditions using

or

key.
End of the setting
⑤ Press the ENTER key to store the settings and return to the READY state.
Interruption of the setting
⑥ When EXIT key (Hold down SHIFT and EXIT) is pressed, the operation is interrupted, becomes
READY state and the state is the one before entering the operation.
Setting flow of withstand voltage test
Start of ACW flow
Withstand
voltage
test
ACW
MODEL 8505
Test
voltage
TEST
VOLTAGE
End of ACW flow
Upper limit
judgment
value
HIGH
SET
Lower limit
judgment
value
LOW
SET
Voltage
rise
time
RAISE
TIME
26
Voltage
fall
time
FALL
TIME
Test time
TEST
TIME
Test
voltage
frequency
TEST
FREQUENCY
Setting of the voltage rise time (rise time)
・Voltage rise time is set till it reaches the test voltage value.
・During the voltage rise, the lower limit judgment of leakage current is not performed.
・Setting range : 0.1~99.9/100~999 seconds
3
2
1
mA
5
4
2
3
6
Enter in the setting mode
① Select the test mode. ACW-IR、IR-ACW、ACW
② Press

or

key.
・ACW-TEST lamp of JUDGE display is turned on.
Setting the voltage rise time
③ Press

or

key.
・Numeric display of TIME display blinks and RAISE lamp displays light.
④ Select the position of the decimal point by RANGE key( RANGE holding down the SHIFT.
Set the number value using
▲
and
▼
key.
Switching of test conditions
・Switch to the other setting conditions using

or

key.
End of Setting
④ Press the ENTER key to store the settings and return to the READY state.
Interruption of setting
⑥ When EXIT key (Hold down SHIFT and EXIT) is pressed, the operation is interrupted, becomes
READY state and the state is the one before entering the operation.
Setting flow of withstand voltage test
Start of ACW flow
Withstand
voltage
test
ACW
MODEL 8505
Test
voltage
TEST
VOLTAGE
End of ACW flow
Upper limit
judgment
value
HIGH
SET
Lower limit
judgment
value
LOW
SET
Voltage
rise
time
RAISE
TIME
27
Voltage
fall
time
FALL
TIME
Test time
TEST
TIME
Test
voltage
frequency
TEST
FREQUENCY
5
5.Setting of withstand voltage test conditions
Setting of the voltage fall time (fall time)
・Fall time of the test voltage is set.
・During the voltage fall, the lower limit judgment of leakage current is not performed.
・Setting range : 0.1~99.9/100~999 seconds and OFF
3
2
1
mA
5
4
2
3
6
Enter in setting mode
① Select the test mode. ACW-IR、IR-ACW、ACW
② Press

or

key.
・ACW-TEST lamp of JUDGE display turns on.
Setting of the voltage fall time
③ Press

or

key.
・Numeric display of TIME display blinks and FALL lamp displays light.
④ Select the position of the decimal point or OFF by RANGE key (RANGE holding down the SHIFT).
Set the fall time using
▲
and
▼
keys.
Switching of the test conditions
Switch to the other setting conditions using

or

key.
End of setting
⑤ Press the ENTER key to store the settings and return to the READY state.
Interruption of setting
⑥ When EXIT key (Hold down SHIFT and EXIT) is pressed, the operation is interrupted, becomes
READY state and the state is the one before entering the operation.
Setting flow of withstand voltage test
Start of ACW flow
Withstand
voltage
test
ACW
MODEL 8505
Test
voltage
TEST
VOLTAGE
End of ACW flow
Upper limit
judgment
value
HIGH
SET
Lower limit
judgment
value
LOW
SET
Voltage
rise
time
RAISE
TIME
28
Voltage
fall
time
FALL
TIME
Test time
TEST
TIME
Test
voltage
frequency
TEST
FREQUENCY
Setting of the test time
・Setting range : 0.1~99.9/100~999 seconds and OFF
・If the test time is set, timer display counts down during the test.
・If the test time is put OFF, the timer display counts up from the test start.
If it exceeds 999, “---“is displayed and test continues till NG judgment or stop.
3
2
1
5
mA
5
3
4
6
Enter in setting mode
① Select the test mode. ACW、ACW-IR、IR-ACW
② Press

or

key.
・ACW-TEST lamp of JUDGE display turns on.
Setting of test time
③ Press

or

key.
・Numeric display of TIME display blinks and TEST lamp displays light.
④ Select the position of the decimal point or OFF by RANGE key (RANGE holding down the SHIFT).
Set the test time using ▲ and ▼ key.
Switching of test conditions
Switch to the other setting conditions using

or

key.
End of setting
⑤ Press the ENTER key to store the settings and return to the READY state.
Interruption of setting
⑥ When EXIT key (HOLD down SHIFT and EXIT) is pressed, the operation is interrupted, becomes
READY state and the state is the one before entering the operation.
Setting flow of withstand voltage test
Start of ACW flow
Withstand
voltage
test
ACW
MODEL 8505
Test
voltage
TEST
VOLTAGE
End of ACW flow
Upper limit
judgment
value
HIGH
SET
Lower limit
judgment
value
LOW
SET
Voltage
rise
time
RAISE
TIME
29
Voltage
fall
time
FALL
TIME
Test time
TEST
TIME
Test
voltage
frequency
TEST
FREQUENCY
5.Setting of withstand voltage test conditions
Setting of test voltage frequency
・Frequency possible : 50Hz and 60Hz
3
2
1
mA
5
LOW
4
2
3
6
Enter in setting mode
① Select the setting mode. ACW-IR、IR-ACW、ACW
② Press

or

key.
・ACW-TEST lamp of JUDGE display turns on.
Setting of the frequency of the test voltage
③ Press

or

key.
・Numeric display of FREQ display blinks.
④ Select the frequency using
▲
and
▼
keys.
Switching of test conditions
Switch to the other setting conditions using

or

key.
End of setting
⑤ Press the ENTER key to store the settings and return to the READY state.
Interruption of setting
⑥ When EXIT key (Hold down SHIFT and EXIT) is pressed, the operation is interrupted, becomes
READY state and the stage is the one before entering the operation.
Setting flow of withstand voltage test
End of ACW flow
Start of ACW flow
Withstand
voltage
test
ACW
MODEL 8505
Test
voltage
TEST
VOLTAGE
Upper limit
judgment
value
HIGH
SET
Lower limit
judgment
value
LOW
SET
Voltage
rise
time
RAISE
TIME
30
Voltage
fall
time
FALL
TIME
Test time
TEST
TIME
Test
voltage
frequency
TEST
FREQUENCY
6.Setting of insulation resistance test (IR) conditions
Setting of test voltage .................................................................................................................... 32
Setting of resistance range ............................................................................................................. 33
Upper limit judgment and lower limit judgment value .................................................................... 34
Setting of mask time...................................................................................................................... 35
Setting of test time ........................................................................................................................ 36
MODEL 8505
31
6.Setting of insulation resistance test (IR) conditions
Setting of test voltage
Set a single test IR, automatic test ACW-IR and insulation resistance test conditions in IR-ACW.
Set the test voltage.
Setting range : 25V, 50V, 100V, 250V, 500V, 1.00kV
2
MΩ
3
1
5
LOW
4
2
3
6
Enter in setting mode
① Select the test mode. ACW-IR、IR-ACW、IR
② Press


or
key.
・IR-TEST lamp of JUDGE display is turned on.
Setting of the test voltage
③ Press

key.
・Select the number blinking display of TEST VOLTAGE display.
④ Select the test voltage using
▲
and
▼
keys.
Switching of test conditions
Switch to the other setting conditions using

or

key.
End of setting
⑤ Press the ENTER key to store the settings and return to the READY state.
Interruption of setting
⑥ When EXIT key (Hold down SHIFT and EXIT) is pressed, the operation is interrupted, becomes
READY state and the state is the one before entering the operation.
Setting flow of insulation resistance test
Start of IR flow
Insulation
resistance
test
IR
MODEL 8505
TEST
End of IR flow
Test
Resistance
voltage
range
VOLTAGE
RESISITANCE
RANGE
Upper limit
judgment
value
HIGH
SET
32
Lower limit
judgment
value
LOW
SET
Mask time
Test time
MASK
TIME
TEST
TIME
Setting of resistance range
Set the resistance range.
Setting range : 2.000MΩ, 20.00MΩ, 200.0MΩ, 2000MΩ, AUTO
※Refer specification column for setting range
2
1
5
MΩ
6
3
4
2
3
6
Enter in setting mode
① Select the test mode. ACW-IR、IR-ACW、IR
② Press

or

key.
・IR-TEST lamp of JUDGE display is turned on.
Select a resistance range
③ Press

or

key.
・MΩ is lit and select the number blinking display of RESISTANCE display.
④ Select resistance range using
▲
and
▼
keys.
Switching of test conditions
Switch to the other setting conditions using

or

key.
End of setting
⑤ Press the ENTER key to store the settings and return to the READY state.
Interruption of setting
⑥ When EXIT key (Hold down SHIFT and EXIT) is pressed, the operation is interrupted, becomes
READY state and the state is the one before entering the operation.
Setting flow of insulation resistance test
Start of IR flow
Insulation
resistance
test
IR
MODEL 8505
TEST
End of IR flow
Test
Resistance
voltage
range
VOLTAGE
RESISITANCE
RANGE
Upper limit
judgment
value
HIGH
SET
33
Lower limit
judgment
value
LOW
SET
Mask time
Test time
MASK
TIME
TEST
TIME
6.Setting of insulation resistance test (IR) conditions
Upper limit judgment and lower limit judgment value
・Set the judgment value of the insulation resistance.
・Setting range: 0.001~9990
Comparison condition
Display value ≧ Upper limit judgment value(HIGH)
HIGH (HI) output
Upper limit judgment value(HIGH)>display value>Lower limit judgment value(LOW)
GOOD (GO) output
Display value ≦ Lower limit judgment value(LOW)
LOW (LO) output
Note: The judgment of upper limit judgment value is not performed during OFF possible mask time.
Setting of upper limit judgment value and lower limit judgment value
MΩ
4
2
5
LOW
2
3
Enter in setting mode
1
4
6
① Select the test mode. ACW-IR、IR-ACW、IR
② Press

or

key
・IR_TEST lamp of JUDGE display is turned on.
Setting of judgment value
③ Press

or

key.
・Numbers of RESISTANCE display blinks, select the lighting of HIGH or LOW.
HIGH Lighting: Perform the setting of high limit judgment value.
LOW Lighting: Perform the setting of low limit judgment value.
④ Select the position of the decimal point by RANGE key (RANGE holding down the SHIFT) or OFF.
Set the value using
▲
and
▼
keys. When continue pressing, the speed of increase and
decrease of numerical value will be faster.
・It is not possible to set the lower limit value to OFF.
Switching of test conditions
Switch to the other setting conditions using

or

key.
End of setting
⑤ Press the ENTER key to store the settings and return to the READY state.
Interruption of setting
⑥ When EXIT key (Hold down SHIFT and EXIT) is pressed, the operation is interrupted, becomes
READY state and the state is the one before entering the operation.
Setting flow of insulation resistance test
Start of IR flow
Insulation
resistance
test
IR
MODEL 8505
TEST
End of IR flow
Test
Resistance
voltage
range
VOLTAGE
RESISITANCE
RANGE
Upper limit
judgment
value
HIGH
SET
34
Lower limit
judgment
value
LOW
SET
Mask time
Test time
MASK
TIME
TEST
TIME
Setting of mask time
・It is a timer to prohibit the judgment from the start of the test for a certain period of time. MASK lamp
is turned on during timer operation. It is used when the waiting time is important for the measurement
of test specimen which has delay like capacitive load etc.
・Setting range : 0.1~99.9 seconds. Not possible during OFF.
3
MΩ
2
1
5
LOW
6
4
2
3
6
Enter in setting mode
① Select the test mode. ACW-IR、IR-ACW、IR
② Press


or
key.
・IR-TEST lamp of JUDGE display is turned on.
Setting of mask time
③ Press


or
key.
・Numeric display of TIME display blinks and MASK lamp displays light.
④ Set the mask time using
▲
and
▼
keys.
Switching of the setting item
Switching to the other setting conditions using

or

key.
End of setting
⑤ Press the ENTER key to store the settings and return to the READY state.
Interruption of setting
⑥ When EXIT key (Hold down SHIFT and EXIT) is pressed, the operation is interrupted, becomes
READY state and the state is the one before entering the operation.
Setting flow of insulation resistance test
Start of IR flow
Insulation
resistance
test
IR
MODEL 8505
TEST
End of IR flow
Test
Resistance
voltage
range
VOLTAGE
RESISITANCE
RANGE
Upper limit
judgment
value
HIGH
SET
35
Lower limit
judgment
value
LOW
SET
Mask time
Test time
MASK
TIME
TEST
TIME
6.Setting of insulation resistance test (IR) conditions
Setting of test time
・Set the test time
・Setting range : 0.2~99.9 seconds
3
MΩ
2
1
5
LOW
4
2
3
6
Enter in setting mode
① Select the setting mode. ACW-IR、IR-ACW、IR
② Press


or
key.
・IR-TEST lamp of JUDGE display is turned on.
Setting of test time
③ Press


or
key.
・Numerical display of TIME display blinks and TEST lamp displays light.
④ Set the test time using
▲
and
▼
keys.
Switching of the setting item
Switch to the other setting conditions using

or

key.
End of setting
⑤ Press the ENTER key to store the settings and return to the READY state.
Interruption of setting
⑥ When EXIT key (Hold down SHIFY and EXIT) is pressed, the operation is interrupted, becomes
READY state and the state is the one before entering the operation.
Setting flow of insulation resistance test
Start of IR flow
Insulation
resistance
test
IR
MODEL 8505
TEST
End of IR flow
Test
Resistance
voltage
range
VOLTAGE
RESISITANCE
RANGE
Upper limit
judgment
value
HIGH
SET
36
Lower limit
judgment
value
LOW
SET
Mask time
Test time
MASK
TIME
TEST
TIME
7.Memory operation
Overview ...................................................................................................................................... 38
Call and setting of memory............................................................................................................ 39
MODEL 8505
37
7.Memory operation
Overview
・The test conditions up to maximum 16 pairs can be memorized in the internal memory.
・The memorized content can be called by an external control and remote control.
Test conditions that can be stored
Setting items
Test conditions
ACW → IR
Test mode
IR → ACW
ACW
Any one
IR
Withstand voltage test ACW
Test voltage
Upper limit judgment value
Lower limit judgment value
Voltage rise time
Voltage fall time
Test time
The frequency of the test voltage
Insulation resistance test IR
Test voltage
Resistance range
Upper limit judgment value
Lower limit judgment value
Mask timer time
Test time
MODEL 8505
38
Call and setting of memory
1
mA
HIGH
4
1
3
2
5
1
7
Call of memory
① Press MEM key (Hold down SHIFT and MEM) at READY state.
・Memory No. blinks in the MEMORY display.
Selection of memory No.
② Select the number using ▲
and
▼
keys.
・Test conditions of the number selected are displayed.
Numbers:1~16
Confirmation and setting of test conditions
③ Enter the setting and confirmation of test conditions after deciding memory No. using

key.
Refer “5. Setting the withstand voltage test (ACW) conditions” and “6. Setting the insulation
resistance test (IR) conditions” for flow of the item.
End of the call
④ Press the ENTER key to store the setting and return to the READY state.
Interruption
⑤ When EXIT key (Hold down SHIFT and EXIT) is pressed, the operation is interrupted, becomes
READY state and the state is the one before entering the operation.
Setting item of withstand voltage test
Start of ACW flow
Withstand
voltage
test
ACW
Test
voltage
TEST
VOLTAGE
End of ACW flow
Upper limit
judgment
value
HIGH
SET
Lower limit
judgment
value
LOW
SET
Voltage
rise
time
RAISE
TIME
Upper limit
judgment
value
HIGH
SET
Lower limit
judgment
value
LOW
SET
Voltage
fall
time
FALL
TIME
Test time
TEST
TIME
Setting item of insulation resistance test
Start of IR flow
Insulation
resistance
test
IR
MODEL 8505
TEST
End of IR flow
Test
Resistance
voltage
range
VOLTAGE
RESISITANCE
RANGE
39
Mask time
Test time
MASK
TIME
TEST
TIME
Test
voltage
frequency
TEST
FREQUENCY
7.Memory operation
This page is blank.
MODEL 8505
40
8.Program operation
Overview ...................................................................................................................................... 42
Flow of program operation ............................................................................................................ 43
Call of program operation.............................................................................................................. 44
Setting of the program ................................................................................................................... 45
MODEL 8505
41
8.Program operation
Overview
Withstand voltage test (ACW) is the only test condition where program is possible.
There are 16 programs from 0~F, setting of maximum 16 test conditions of each step in one program
and continuous test is possible.
Example:
0
Step
1
2
3
4
Test
voltage
2.00kV
1.00kV
15.0
10.0
Elapsed time (s)
0.0
! Caution
25.0
30.0
Step 0 (rising section) and step 4 (falling section) are done only in upper limit judgment.
Lower limit judgment is not performed.
Like section 1 and section 3, the test voltage is performed in a certain interval or together with upper
limit judgment and lower limit judgment.
Upper limit Lower limit
judgment
judgment
value
value
(mA)
(mA)
Next
step
Test
voltage
(kV)
Timer
Time
(s)
0
ON
1.00
10.0
10.00
2.00
From 0kV to 1kV after 10 seconds
1
ON
1.00
5.0
10.00
2.00
Maintain 1kV for 5 seconds
2
ON
2.00
0.1
10.00
2.00
Rising from 1kV to 2kV
3
ON
2.00
10.0
10.00
2.00
Maintain 2kV for 10 seconds
4
END
0.00
5.0
10.00
2.00
From 2kV to 0kV after 5 seconds
5
6
7
8
9
A
B
C
D
E
F
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
END
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Step No.
Remarks
At the “END”, test is completed
with this step.
At the end of the sentence, there is memo of program operation for customers, so use it.
MODEL 8505
42
Flow of program operation
It shows the flow of setting of program operation of the withstand voltage test from the start to the end.
For explanation besides step numbers refer to the following pages.
READY state of standard
SHIFT and PROG
Step No.
Program No.
Input program No.
READY state of the program
Change program No, and step No.
READY lamp light on
SHIFT and PROG
is pressed to chang the program No.
Proceed to the selection of step No.
Select the step No.
8
Setting is memorized
When SHIFT and EXIT are pressed, the operation is
if ENTER key is pressed.
interrupted and returns to READY state of STEP0.
Test
To the next step No.
ON/END
ACW
voltage
TEST
VOLTAGE
Upper limit
judgment
value
HIGH
SET
Lower limit
judgment
value
LOW
SET
Timer
TIMER
50/60Hz is set during STEP 0.
Selection of frequency is not possible
during state other then STEP 0.
MODEL 8505
43
Test
voltage
frequency
TEST
FREQUENCY
8.Program operation
Call of program operation
Program No. is being called.
1
mA
HIGH
3
LOW
1
2
Enter in the program
① Press the PROG (Hold down the SHIFT and PROG) in the READY state.
・PROG lamp is turned on in MEMORY display and blinks program no.
Selection of program numbers
② Selection is done using
▲
and
▼
keys. 16 units of 0~F
End of the call of program operation
③ Press the program key and the program test returns to the READY state.
Returns to READY state of panel setting mode from program operation
・During the READY state of program test, if

and

keys are pressed it returns to the
state it was before entering the program mode. Test MODE (MODE) lamp blinks at this time.
・When ENTER key is pressed, it returns to the READY state of the panel setting mode.
MODEL 8505
44
Setting of the program
Setting is done for each program number and for each step number.
1 3
mA
HIGH
8
LOW
3
1
5
7
9
2
4
6
Enter in the program
① Press the PROG key (Hold down the SHIFT and PROG) in the READY state.
・Program lamp is turned on in MEMORY display and program number is displayed by blinking.
Selection of program No.
② Number is selected using
▲
and
▼
keys.
16 units of 0~F
Selection of step No.
③ The digit of step number blinks using
④ Select the number using ▲
and

▼
key.
keys.
16 units of 0~F
Setting of the test conditions of step
⑤ Enter in the setting of test conditions using

By pressing the

key.
key, it switches to the following content.
Test voltage setting
⑥ Setting of the test voltage of step is done using
▲
and
▼
keys. (0.00~5.50kV)
Depending on the test voltage of previous step, the rise, fall and maintaining of the test voltage is
performed.
Example) Set 5.00kV when the voltage of previous step is 2.00 kV
→Test voltage gradually increase till 2.00~5.00kV
Example) Set 0.00 kV when the test voltage of previous step is 2.00 kV
→Test voltage gradually fall till 2.00~0.00kV
Example) Set 2.00 kV when the test voltage of previous step is 2.00 kV
→Maintain next step till 2.00kV
⑦ Press

key.
Upper limit judgment value setting
⑧ Sets the leakage current upper limit judgment value of the step using
▲
and
▼
keys.
▲
and keys
▼ .
(0.01~20.00mA)
Lower limit judgment value setting
⑨ Sets the leakage current lower limit judgment value of the step using
(0.01~19.99mA or OFF)
※In case the test voltage is on rise or fall, lower limit judgment value is not performed.
MODEL 8505
45
8
8.Program operation
Test time setting
⑩ Sets the test time of the step using
▲
and
▼
keys.
(0.1~99.9/100~999 seconds)
Test voltage frequency setting(step 0 only)
⑪ Sets the test voltage of the frequency using
▲
and
▼
keys.
Step 0 is only possible and the remaining steps follow this setting.
Next step switching over setting
⑫ Sets the presence and absence of the switching over of next step using
▲
and
▼
keys.
(ON:Switching over, END:End without switching over)
※Step F only for END fixed.
(Later returns to the test voltage setting.)
End of the test conditions setting of the step
⑬ Returns to READY state if ENTER key is pressed.
Interruption of step conditions of program operation
⑭ When EXIT key (EXIT holding down SHIFT) is pressed, the content edited is discarded and
returns to the state just before entering test conditions setting of the step.
Return from program operation to READY state of the panel setting mode
⑮ In the READY state of program operation, if

and

keys are pressed, it enters in the
test conditions setting of the panel setting mode.
・Returns to READY state of panel setting mode if ENTER key is pressed.
Test
To the next step No.
ON/END
ACW
voltage
TEST
VOLTAGE
Upper limit
judgment
value
HIGH
SET
Lower limit
judgment
value
LOW
SET
Timer
TIMER
Test
voltage
frequency
TEST
FREQUENCY
50/60Hz is set during STEP 0.
! Caution
MODEL 8505
To perform test conditions setting of another step, once complete or cancel the setting and
reselect the step No.
46
9.Test method (From the start of the test till the judgment)
Method operation of single withstand voltage test .......................................................................... 48
Operation method of single insulation resistance test ...................................................................... 49
Operation method of automatic test................................................................................................ 50
Operation method of program operation test................................................................................... 51
MODEL 8505
47
9.Test method (From the start of the test till the judgment)
Method operation of single withstand voltage test
Test start~Test end
① When START switch is pressed, DANGER lamp is turned on and the test starts.
② ACW-TEST lamp turns on during high voltage output.
③ During the test, TEST/H.V.OUT output and ACW-TEST output is turned on using remote I/O
connector.
④ When the test is ended, TEST/H.V.OUT output and ACW-TEST output is turned off, judgment
result and END output is turned on.
Interruption of the test
When STOP switch is pressed during the test, the test is interrupted.
It returns to the READY state.
Judgment result
When the judgment is GOOD
When the test time has elapsed, the test is ended and the judgment is GOOD and GOOD, ACW
GOOD and END are turned on.
When the judgment is NG
During the test, in case of NG judgment of the upper limit value and the lower limit value,
the test is interrupted and high voltage output is turned off. Judgment result and END are
the output.
Lamp lighting condition of ACW test time
Types of lamp
READY
During RAISE
During test
During FALL
During judgment
DANGER
-
●
●
●
-
PROG
-
-
-
-
-
V 、kV
●
●
●
●
●
mA、MΩ
●
●
●
●
●
HIGH SET
●
●
●
●
●
LOW SET
●(Lower limit
judgment setting
time)
●(Lower limit
judgment setting
time)
●(Lower limit
judgment setting
time)
●(Lower limit
judgment setting
time)
RAISE
-
●
-
-
TEST
●
-
●
-
FALL
-
-
-
●
●(Lower limit
judgment setting
time)
●(Test end time
in case of
RAISE)
●(Test end time
in case of
TEST)
●(Test end time
in case of
FALL)
MASK
-
-
-
-
-
ACW-TEST
-
●
●
●
-
IR-TEST
-
-
-
-
-
GOOD
-
-
-
-
●(GOOD time)
HIGH
-
-
-
-
LOW
-
-
-
-
ACW-IR
-
-
-
-
●(Upper limit
judgment time)
●(Lower limit
judgment time)
-
I-ACW
-
-
-
-
-
ACW
●
●
●
●
●
IR
-
-
-
-
-
READY
●
-
-
-
-
DISCHARGE
-
-
-
-
-
MODEL 8505
48
Operation method of single insulation resistance test
Test start~Test end
① When START switch is pressed, DANGER lamp is turned on and the test starts.
② IR-TEST lamp turns on during high voltage output.
③ During the test, TEST/H.V.OUT output and IR-TEST output is turned on using remote I/O
connector.
④ When the test is ended, TEST/H.V.OUT output and IR-TEST output is turned off, judgment result
and END output is turned on.
Interruption of the test
When STOP switch is pressed during the test, the test is interrupted.
It returns to the READY state.
Judgment result
When the judgment is GOOD
When the test time has elapsed, the test is ended and the judgment is GOOD and GOOD, IR GOOD
output and END are turned on.
When the judgment is NG
During the test, in case of NG judgment of upper limit value and the lower limit value, the test is
interrupted and high voltage output is turned off. Judgment result and END are the output.
Lamp lighting condition of IR test time
Types of lamp
During MASK
During test
During
discharge
Judgment time
DANGER
-
●
●
●
-
PROG
-
-
-
-
-
V 、kV
●
●
●
●
●
mA、MΩ
●
●
●
●
●
LOW SET
●(Upper limit
judgment value
setting time)
●
●(Upper limit
judgment value
setting time)
●
●(Upper limit
judgment value
setting time)
●
●(Upper limit
judgment value
setting time)
●
●(Upper limit
judgment value
setting time)
●
RAISE
-
-
-
-
-
HIGH SET
MODEL 8505
READY
TEST
●
●
●
●
●
FALL
-
-
-
-
-
MASK
-
●
-
-
-
ACW-TEST
-
-
-
-
-
IR-TEST
-
●
●
●
-
GOOD
-
-
-
-
●(GOOD
time)
HIGH
-
-
-
-
●(Upper limit
setting time)
LOW
-
-
-
-
●(Lower limit
setting time)
ACW-IR
-
-
-
-
-
IR-ACW
-
-
-
-
-
ACW
-
-
-
-
-
IR
●
●
●
●
●
READY
●
-
-
-
-
DISCHARGE
●
-
-
◎
-
49
9
9.Test method (From the start of the test till the judgment)
Operation method of automatic test
Test start~Test end
① When START switch is pressed, DANGER lamp is turned on and the test starts.
② Depending on test order, ACW-TEST lamp or IR-TEST is turned on during high voltage output.
③ During the test, TEST/H.V.OUT output, ACW-TEST output and IR-TEST output are turned on and
END output is turned off using remote I/O connector. However, ACW-TEST output and IR-TEST
output are switched over depending on the test order.
④ When the test is ended, TEST/H.V.OUT output, ACW-TEST output and IR-TEST output are turned
off, judgment result and END output is turned on.
Interruption of the test
When STOP switch is pressed during the test, the test is interrupted.
It returns to the READY state.
Judgment result
When the judgment is GOOD
When the test time is elapsed, the test is ended and the GOOD judgment is performed and GOOD,
ACW GOOD output, IR GOOD and END are turned on.
When the judgment is NG
During the test, in case of NG judgment of upper limit value and the lower limit value, the test is
interrupted and high voltage output is turned off. Judgment result and END are the output.
Lamp lighting condition is the combination of the lamp lighting condition of
ACW test mode time and IR test mode time.
MODEL 8505
50
Operation method of program operation test
Test start~Test end
① When START switch is pressed, DANGER lamp is turned on and the test starts.
② Depending on test order, ACW-TEST lamp is turned on during high voltage output.
③ During the test, TEST/H.V.OUT output and ACW-TEST output are turned on and END output is
turned off using remote I/O connector.
④ When the test is ended, TEST/H.V.OUT output and ACW-TEST output are turned off, judgment
result and END output is turned on.
Interruption of the test
When STOP switch is pressed during the test, the test is interrupted.
It returns to the READY state.
Judgment result
When the judgment is GOOD
When the test is elapsed, the test is ended and the GOOD judgment is performed and GOOD, ACW
GOOD output and END are turned on.
When the judgment is NG
During the test, in case of NG judgment of upper limit value and lower limit value, the test is
interrupted and high voltage output is turned off. Judgment result and END are the output.
Lamp lighting condition of program operation test time
MODEL 8505
Types of lamp
READY
During test
Judgment time
DANGER
-
●
-
PROG
●
●
●
V 、kV
●
●
●
mA、MΩ
●(Display of upper limit
judgment value)
●(Measurement display)
●(Display of measurement
value when the test ends)
HIGH SET
●
●
●
LOW SET
●(Lower limit judgment
value setting time)
●(Lower limit value
setting time)
●(Lower limit value
setting time)
RAISE
-
TEST
●
FALL
-
MASK
-
-
-
ACW-TEST
-
●
-
IR-TEST
-
-
-
GOOD
-
-
●(GOOD time)
HIGH
-
-
●(upper judgment time)
LOW
-
-
●(Lower judgment time)
ACW-IR
-
-
-
IR-ACW
-
-
-
●(When setting voltage
is higher than the previous
step)
●(When setting voltage
is equal to the previous
step)
●(When setting voltage
is lower than the previous
step)
●(When RAISE during
end of the test)
●(When TEST during end
of the test)
●(When FALL during end
of the test)
ACW
●
●
●
IR
-
-
-
READY
●
-
-
DISCHARGE
-
-
-
51
9
9.Test method (From the start of the test till the judgment)
This page is blank.
MODEL 8505
52
10.Other functions
Double action start ........................................................................................................................ 54
GOOD hold .................................................................................................................................. 54
Momentary start ............................................................................................................................ 54
FAIL mode ................................................................................................................................... 54
NG start ........................................................................................................................................ 54
Setting method .............................................................................................................................. 55
Setting of the buzzer...................................................................................................................... 56
Interlock ....................................................................................................................................... 57
MODEL 8505
53
10.Other functions
Double action start
After STOP input is off, START input is enabled for 0.5 second.
Setting no. of a
Item
Setting done
1
Setting not done
0
Default value
○
GOOD hold
Three conditions can be selected for holding time of GOOD judgment condition
Setting no. of b
Item
Judgment after 0.2seconds output returns to READY state
Default value
0
Hold the judgment, after stop signal output, re-start is possible with start
1
signal
Hold the judgment, without stop signal, re-start is possible with start
2
○
Setting no. of c
Default value
signal
Momentary start
Test is done only when the START switch is hold and pressed.
Item
Setting done
1
Setting not done
0
○
Setting no. of d
Default value
FAIL mode
The release of NG, PROTECTION is limited to the main STOP switch.
Item
Setting done
1
Setting not done
0
○
NG start
Following the NG decision, the condition to start the test is set.
ON :Even if NG judgment is not released by STOP, the test is started by START.
OFF:NG judgment is released by STOP and test is started by START.
Setting no. of e
Item
MODEL 8505
OFF
0
ON
1
54
Default value
○
Setting method
Setting item
Double action start
GOOD hold
Momentary start
FAIL mode
NG start
Selectable LED
ⓐ
ⓑ
ⓒ
ⓓ
ⓔ
1
a b c
5
d e
2
4
3
1
4
6
2
Enter in the other settings
① Press SET key (Hold down SHIFT and SET) for 3 seconds in the READY state.
・Time display will blink “OTH”.
Enter in the setting item
② Enter in the setting item using
▼
key.
・TEST VOLTAGE display part ⓐ blinks and setting condition in CURRENT/RESISTANCE display
is turned on.
Selection of setting item
③ One of ⓐ、ⓑ、ⓒ、ⓓ、ⓔ is selected using

and

keys. Selected item blinks.
Setting
④ Setting no. is set by using
▲
and
▼
keys.
Refer the contents of the previous page.
End of the setting
⑤ When ENTER key is pressed, the setting is stored and returns to READY state.
Interruption of the setting
⑥ When EXIT key (Hold down SHIFT and EXIT) is pressed, the setting is interrupted and returns to
READY state. The setting content at that time will be the state it was before entering the setting.
MODEL 8505
55
10
10.Other functions
Setting of the buzzer
Buzzer rings when the judgment passes or fails.
The on/off setting of the buzzer is possible using setting of the front panel.
2
6
3
5
2
4
1
3
5
7
Enter in the setting
① Press SET key (Hold down SHIFT and SET) for 3 seconds in the READY state.
・TIME display will blink “OTH”
② “BUZ” is selected using
③ Enter in the setting using

▼
key.
key.
・Setting state blinks in CURRENT/RESISTANCE display.
Selection of GOOD buzzer
④ Select “GO-0” (Pass buzzer off) using
⑤ “GO-1” (Pass buzzer on) using
▲

key.
key and “GO-0” (pass buzzer off) using
▼
key.
・Setting state blinks in CURRENT/RESISTANCE display.
Selection of NG buzzer
⑥ Select “NG-0” (Fail buzzer off) using
⑦ “NG-1” (Fail buzzer on) using
▲

key,.
key and “NG-0” (Fail buzzer off) using
▼
key.
・Setting state blinks in the CURRENT/RESISTANCE display.
Confirmation of the buzzer
The confirmation of the on/off setting is possible depending on the pressing of STOP switch.
Setting range
For pass
For fail
judgment
judgment
Buzzer sound
GO-1
NG-1
On
GO-0
NG-0
Off
Depending on

and

keys, it returns to the selection of ④ ⑤GOOD and NG buzzer.
End of the setting
⑧ When ENTER key is pressed, setting is memorized and returns to the READY state.
Interruption of the setting
⑨ When EXIT key is pressed (EXIT holding SHIFT), the setting is interrupted and returns to READY
state. The setting content at that time will be the state it was before entering the setting.
MODEL 8505
56
Interlock
Sets to enable and disable the interlock signal of remote I/O connector.
2
5
3
2
1
3
4
6
Enter in the setting
① Press SET key (Hold down SHIFT and SET) for 3 seconds in READY state.
・”OTH” blinks in the TIME display.
② Select “ITL” using

③ Enter the setting using
key.
▼
key.
・Setting state blinks in the CURRENT/RESISTANCE display.
Setting
④ Select enable “ON” and disable “OFF” using
▲
and
▼
keys.
・Setting state blinks in the CURRENT/RESISTANCE display.
End of the setting
⑤ When ENTER key is pressed, the setting is memorized and returns to READY state.
Interruption of the setting
⑥ When EXIT key (EXIT holding SHIFT) is pressed, the setting is interrupted and returns to the
READY state.
The setting content at that time will be the state it was before entering the setting.
MODEL 8505
57
10
10.Other functions
This page is blank.
MODEL 8505
58
11.Remote I/O
Overview of the test depending on remote I/O................................................................................ 60
From the test conditions setting of remote I/O to test start............................................................... 61
Connector pin array and pin function ............................................................................................. 62
Interlock signal ............................................................................................................................. 63
Protective function operation (PROTECTION) .......................................................................... 63
Input signal ................................................................................................................................... 64
Output signal and the control power supply.................................................................................... 65
Timing chart ................................................................................................................................. 66
MODEL 8505
59
11.Remote I/O
Overview of the test depending on remote I/O
The control of start/stop of the test is possible with sequencer etc. depending on the remote I/O
connector ⑤ of rear panel.
・ Depending on the input on/off of the address number of the test conditions by registering the test
conditions using memory operation “7. Memory Operation”, it is possible to test by memory contents
reading from outside. Test by panel setting mode is also possible.
・ The control by the sequencer etc. Becomes easy because of the output of READY of test conditions,
during test, end of the test and also judgment result with an open collector.
・ Interlock setting for the safety and guarantee and the signal corresponding to each condition of 8505
outputs through open collector.
・ Input and output signals are insulated from internal circuit by photo coupler. As it has a power supply
of DC24V 0.1A, it can be used as a power supply for the external control.
! Caution
It does not start the test from the START signal of remote I/O connector in case there is a setting
to start from START command of RS-232C.USB interface. Change the settings. See below for
the reference.
「0」にします。
The setting value is made 0 as shown in above figure.
Setting item
START
Start of the test from front panel or remote out
Start of the test by START command (at REMOTE state)
Setting no.
Default value
0
1
○
-
Setting value is made 0 as in the diagram.
Refer to the separate manual [RS-232C・USB interface] for operation method.
MODEL 8505
60
From the test conditions setting of remote I/O to test start
mA
HIGH
Before entering in the setting
・Refer “Selection of test mode” of P21 for select method of test mode to implement.
Enter in the setting
① REMOTE key is pressed in READY state.
REMOTE lamp is turned on.
START from the panel is not possible.
Stop key can be used.
② Select ACW-IR or IR-ACW in test mode.
Control the remote I/O
③ REAR MODE of remote I/O is put on.
Select the memory No.
④ Address is set in ON/OFF signal of MEM SET 1, 2, 4, 8, 10 of remote I/O. When all memory No. is
off, memory No. display is off and it becomes panel setting mode.
Start the test
⑤ Test starts when START of remote I/O is turned ON by non-voltage contact.
MODEL 8505
61
11
11.Remote I/O
Connector pin array and pin function
I/O
-
I
O
-
COM
Signal name
+24V
NC
START
STOP
INTERLOCK
MEM SET1
MEM SET2
MEM SET4
MEM SET8
TEST/H.V.OUT
READY
PROTECTION
GOOD
ACW HIGH
ACW GOOD
IR HIGH
IR GOOD
NC
COM
REAR MODE
ACW-MODE
Pin No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
I
COM
O
I
O
-
O
-
O
-
COM
IR-MODE
22
COM
ACW-TEST
23
24
IR-TEST
25
TEST
26
MEM SET10
END
NC
NC
NG
ACW LOW
NC
IR LOW
NC
COM
27
28
29
30
31
32
33
34
35
36
Function
DC24V Outputs control power supply (capacity 0.1A)
Free pin(Do not hook up etc. for wiring)
Start input signal
Stop input signal
Interlock signal
Input binary code calling memory momentarily
Valid from memory No. 1~No.15
For memory No.16, use pin No.27
Outputs High voltage terminal during voltage output time
Outputs during READY state time
Outputs during protective function operation time
Outputs during pass judgment time
Outputs during upper limit judgment time of withstand voltage test
Outputs during pass judgment time of withstand voltage test
Outputs during upper limit judgment time of insulation resistance test.
Outputs pass judgment time of insulation resistance test.
Free pin(Do not hook up etc. for wiring)
Common(Common with No.23 and36)
Becomes a test mode switching operation (ACW, IR) from rear panel.
Mode setting of withstand voltage
(REAR: Valid at the time of MODE setting)
Mode setting of insulation resistance test
(REAR: Valid at the time of MODE setting)
Common (Common with No. 19 and 36)
Outputs during test of withstand voltage test.
Does not output when ACW-TEST blinks.
Outputs during test of insulation resistance test
Does not output when IR-TEST blinks
Outputs during the test
Does not output when ACW-TEST and IR-TEST blinks.
Memory call
(memory No.16)
Output during test end
Free pin(Do not hook up etc. for wiring)
Free pin(Do not hook up etc. for wiring)
Output during fail judgment time
Output during low limit judgment time of withstand voltage test
Free pin(Do not hook up etc. for wiring)
Output during lower limit judgment time of insulation resistance test
Free pin(Do not hook up etc. for wiring)
Common(Common with No.19 and23)
[Kind of input and output]
I
:Input
O
:Open collector output
COM :Input Output common
-
:Free pin
18
1
36
19
Connector used:36P Amphenol
MODEL 8505
62
Interlock signal
Interlock is a function to shut off the output by linking with an external device for ensuring the safety of
the workers.
There is an interlock state when INTER-LOCK of remote I/O connector is opened and start of the test is
not possible.
During operation of interlock function, there is a display of ERR LOCK in test voltage indicator, output
of 8505 is shut off and all the key operations are disabled.
To release the interlock, INTER-LOCK of remote I/O connector and COM is short circuited and STOP
switch is pressed with “L” level.
After ERR LOCK is off and READY lamp turned on, the test is possible.
Note: The supplied remote I/O plug (36P) has short circuited INTER-LOCK and COM.
In case there is no remote I/O plug, release is possible reintroducing the power, with the help of
setting operation of interlock of “10. Other functions”.
As shown in the connection diagram example given below, allow the adequate interlock processing
where safety is considered like linking with an external device etc.
Remote I/O connector
18
5
1
External device
Open close jig switch
36
23
19
Interlock connection example
11
Protective function operation (PROTECTION)
The protective function operation is an action that outputs PROTECTION due to the remote I/O
connector during the undermentioned time of conditions.
・During the time when the test is ended and even when 10 seconds lapsed, the discharge of test
specimen is not completed
・During the time when the test is ended and even when 10 seconds lapsed, the voltage output
does not fall
・During the test when interlock input is off
Method to cope
・Refer “13. Error message”
MODEL 8505
63
11.Remote I/O
Input signal
Start and stop control of this tester is possible by the external input signal.
Besides, it is possible to call the setting of the registered test conditions in the memory.
(1) Input signal specification (Pin No.2~9, 20~22, 27)
Control input:Active LOW
Input level: “H”=16.8~24V
“L”=0~3.8V
L level flow current:Ice=10mA
L level minimum pulse width:40ms
Isolation Yes
(2) Internal circuit configuration
8505
+24V
Photo coupler
Remote I/O
2.4kΩ
Input pin
(3) Example of control using transistor
Design the collector current with maximum 10mA.
+24V
Photo coupler
2.4kΩ
COM
(4) Example of control using external switch
Provide the circuit to prevent relay or chattering of the switch.
+24V
Photo coupler
External switch
2.4kΩ
COM
MODEL 8505
64
Output signal and the control power supply
Each state of output signal of 8505 can be taken out.
As it is equipped with control power supply of DC24V, direct drive like relay etc. is possible.
(1) Output signal specification (Pin No.10~17, 24~26, 28, 31, 32, 34)
Signal format:Open collector output
Maximum load voltage:DC30V
Maximum output current:DC30mA
Isolation Yes
Output saturation voltage:Less than DC1.6V
(2) Control power supply specification(Pin No. 1)
Output voltage:DC24V
Current capacity :DC0.1A
8505
+24V
1
Each output signal
Relay
PIN No.
10~17、24~26、
28、31、32、34
COM
PIN No.
19、23、36
Example of relay drive connection
8505
+24V
1
11
Each output signal
PIN No.
10~17、24~26、
28、31、32、34
COM
PIN No.
19、23、36
Example of getting signal level
! Caution
MODEL 8505
・Use output signal less than DC30V 30mA.
・In case of inductive load control like relay etc., connect the coil and the diode in parallel and
absorb the counter electromotive force.
65
11.Remote I/O
Timing chart
<ACW-GOOD>
More than 40ms
START
Minimum 20ms
During GOOD hold ,
continuous.
READY
TEST
HV OUT
W-TEST
SIN wave output
(Test voltage output)
Zero cross end
Maxmum 20ms
GOOD
During GOOD hold, continuous
END
During GOOD hold, continuous
<IR-GOOD>
More than 40ms
START
About 20ms
During GOOD hold,
continuous
READY
TEST
HV OUT
I-TEST
Test voltage output
About 10ms
GOOD
During GOOD hold, continuous
END
During GOOD hold, continuous
DISCHARGE
MODEL 8505
※OFF after the end of the discharge
66
12.PC remote control
RS-232C・USB Interface ............................................................................................................... 68
MODEL 8505
67
12.PC remote control
RS-232C・USB Interface
Refer to the separate instruction manual I-02224.
MODEL 8505
68
13.Error message
Error display ................................................................................................................................. 70
Coping with error display .............................................................................................................. 70
MODEL 8505
69
13.Error message
When an error occurs, depending on the situation it is displayed as shown in the table.
Cope with it after confirming the error number.
Example) When interlock input is off
TEST VOLTAGE
CURRENT/RESISTANCE
mA
MΩ
kV
Error display
Error display
Counter measure
No.
Cause


Even when 10 seconds elapsed, the discharge of the test
specimen is not completed
D
※


When interlock input is off
B
※






In momentary operation, when the start signal is turned off
during withstand voltage test
In momentary operation, when the start signal is turned off
during insulation resistance test
During withstand voltage test , when the internal components
are in overheated state


When the internal components become abnormal or breakdown
C
C
E
※
A
※
※:Outputs PROTECTION from remote I/O connector ⑤
Coping with error display
Counter measure
No.
A
Method to cope
Immediately turn OFF the power. Contact the agency or this company as there is a possibility of
breakdown of this 8505 tester.
Interlock input is now OFF. Connect interlock input correctly by reviewing the connection or the
B
sequence. STOP switch ⑬ is pressed and brought to READY state.
(Besides, release interlock function 10. Other functions)
C
STOP switch ⑬ is pressed and brought to READY state. Review connection or sequence such
that the start signal during the test is not OFF.
When the capacity of the test specimen is large, discharge is not possible and there is a case
D
where high voltage remains. Leave it alone for some time and continue the discharge. When the
discharge is completed, it is possible that the STOP command or error display in STOP switch is
released.
It is possible that the internal components are in the overheated state when the test is done for a
E
long time. Wait for a while at the power on state till the heat is dissipated. When the heat
dissipation is completed, it is possible that the STOP command or error display in STOP switch
is released.
MODEL 8505
70
14.Maintenance
Cleaning ....................................................................................................................................... 72
Problem solving ............................................................................................................................ 72
Calibration .................................................................................................................................... 72
MODEL 8505
71
14.Maintenance
Cleaning
In order to remove the dirt from this tester, wipe lightly by a soft cloth with small amount of water and
small amount of mild neutral detergent.
Do not use detergents containing solvents like benzene, alcohol, paint thinner etc. It may cause
deformation and decoloration.
Problem solving
In order to solve the problem, check the description in “Problem solving” and contact the nearest dealer
or nearest sales office.
When breakdown goods are to be returned
The goods are to be packed so that it does not get damaged during transportation and write and attach
the breakdown description as well. There is no guarantee for the damage during transportation.
When you think that there is a breakdown
Conditions
Confirmation
No display even when the power
Check if the power cord is
switch is turned on.
unplugged.
Countermeasure
Plug in the power cord.
Cannot operate the keys.
Is it in the key lock state?
Release the key lock.
Test is not started even when
START switch is pressed.
・Is READY lamp turned on?
・Is REMOTE lamp turned off?
・Check the settings of other functions.
・START switch is disabled during remote
control.
Refer to Chapter 12~Chapter 13 for
remote control.
When you press START switch
  is blinked.
  is blinked.
Error display
Error display
Release the interlock with the reference
of interlock or external control interlock
of other functions.
Refer to the error display.
Calibration
For the long protection of accuracy, it is recommended to calibrate the instruments every year.
Customers are requested to contact the sale offices of Tsuruga Electric Corporation or the
dealer/distributor of Tsuruga Electric Corporation for the calibration.
However, the repair and calibration may be refused if the production of the product is abolished after
certain elapse of time or if the warranty range is not covered.
MODEL 8505
72
15.Specifications
Withstand voltage test ................................................................................................................... 74
Insulation resistance test ................................................................................................................ 76
Memory operation......................................................................................................................... 77
Program operation......................................................................................................................... 77
Other functions ............................................................................................................................. 78
Input Output signal ....................................................................................................................... 78
RS-232C・USB Interface ............................................................................................................... 79
General specification..................................................................................................................... 80
Setting of the default value ............................................................................................................ 80
Dimensions ................................................................................................................................... 82
MEMO ......................................................................................................................................... 83
MODEL 8505
73
15.Specifications
Withstand voltage test
・Test voltage
Applied voltage
Output capacity
Wave form
Power frequency
Voltage fluctuation rate
Voltage application method
Applied voltage setting
・Voltage measurement
Rectification method
Digital display
・Current measurement
Rectification method
Digital display
MODEL 8505
:AC 0.2~5.00kV
:100VA (5kV, 20mA) Continuous application time of the maximum current output within 30
minutes
:Sine wave (Rate of strain:Less than 5% No-load)
:50/60Hz (Regardless of the power frequency 50/60Hz switchable)
:Less than 15% (Maximum rating → No-load:In resistive load)
:Zero cross switch
After the time up and NG judgment time, cut off applied voltage
:Digital setting (Setting resolution 0.01kV)
Setting accuracy ± (1.5%+20V) of the setting No-load
:Average rectified effective value display
:Display range 0.00~6.00kV
Resolution 0.01kV
Measurement accuracy ± (1.5% of rdg. ), Less than 500V± (1.5% of rdg. +20V)
Character 10mm (Green LED)
Operation Show the applied voltage during the test
During the end of the test, retain the display of the end time of the test.
The value of NG judgment is not necessarily the value at the time of
NG judgment from the relationship of response speed.
Response time 100ms
:Average rectified effective value display
:Measurement range 0.00~20.00mA
Resolution 0.01mA
Measurement accuracy ± (2% of rdg. +0.05mA)
Character 10mm (Green LED)
Operation Display the leakage current during the test
At the end of the test, retains the display of the end time of the test.
Analog comparator operation becomes over display
Over display  displays light
When it exceeds 20.00mA When overcurrent like spark etc. flows, when the analog
comparator is activated.
Response time 100ms
74
:Upper limit Digital comparator and analog comparator detects the current that exceeds 20mA
Lower limit Digital comparator
Setting
:Setting range Upper limit 0.01~20.00mA
Lower limit 0.01~19.99mA/ OFF
Resolution 0.01mA
Judgment conditions :Upper limit setting>Leakage current>Lower limit setting ・・・ GOOD
Upper limit setting≦Leakage current ・・・・・・・・・・・・・・・・・・・・・ HIGH NG
Lower limit setting≧Leakage current・・・・・・・・・・・・・・・・・・・・・・ LOW NG
Judgment accuracy :± (2%+0.05mA) to the set value
Judgment method
・Test time
Setting range
Setting resolution
Accuracy
:0.1~99.9/100~999 seconds and OFF (continuous)
:0.1 second/1 second
During test
When the time is set, displays the remaining time.
When setting is OFF, displays the elapsed time
At the end of the test Displays remaining time
By timer OFF setting during NG judgment
Displays the elapsed time
Waiting time
Displays the setting value
:Set value±(0.1% +20ms)
・Rise/Fall time (Rise time RAISE/Fall time FALL)
Function
:The function to raise and fall the test voltage output by setting time
Setting range
:0.1~99.9/100~999 seconds and OFF (OFF is FALL time only)
Setting resolution
:0.1 second/1 second
Accuracy
:Set value±(0.1% +20ms)
Output voltage
T1
T2
T3
Elapsed time
T1:Rise time
T2:Test time
T3:Fall time
Application time=T1+T2+T3
15
MODEL 8505
75
15.Specifications
Insulation resistance test
:DC25V/50V/100V/250V/500V/1000V
:Within 130% of the rated voltage
:1mA
:Less than 15mA
:Measured value display 0~9990
Zero suppression
Over display (when input open or over) Displays light
Auto range
:Resolution within measurement range is switched automatically, Rise time is switched at 2000
and fall time is switched at 179
Operation Insulation resistance value is displayed during the test
At the end of the test, retains the display of the end time of the test
Externally applied voltage :Less than 1.2 times measured voltage, Maximum 600V 50/60Hz Less than 10 seconds
Measurement range and Accuracy:
Rated measurement voltage
No load voltage
Rated current
Short-circuit current
Display
Rated
measurement
voltage
Resistance
range
2.000MΩ
Resistance
measurement range
0.000~2.000MΩ
2.010~4.990MΩ
DC 25V
DC 50V
20.00MΩ
1.80~20.00MΩ
20.10~49.90MΩ
Middle
value
500kΩ
100.1~200.0MΩ
0.000~2.000MΩ
2.010~4.990MΩ
20.00MΩ
DC100V
DC250V
±30%of rdg.
5MΩ
±(2%of rdg.+3digit)
※
100kΩ
100kΩ
±(2%of rdg.+3digit)
50MΩ
100kΩ
± 5%of rdg.
1MΩ
±30%of rdg.
500kΩ
20.00MΩ
200.0MΩ
20.10~49.90MΩ
100kΩ
±30%of rdg.
100kΩ
±(2%of rdg.+3digit)
100kΩ
± 5%of rdg.
1MΩ
±30%of rdg.
1MΩ
± 5%of rdg.
10MΩ
±30%of rdg.
100.1~200.0MΩ
50MΩ
180 ~2000 MΩ
2010 ~9990 MΩ
0.00~20.00MΩ
18.0~200.0MΩ
201.0~499.0MΩ
500MΩ
5MΩ
1001 ~2000 MΩ
±(2%of rdg.+3digit)
±30%of rdg.
50MΩ
100kΩ
±(2%of rdg.+3digit
※
1MΩ
±30%of rdg.
1MΩ
±(2%of rdg.+3digit)
1MΩ
± 5%of rdg.
10MΩ
±30%of rdg.
500MΩ
Caution:During AUTO range measurement, ※mark becomes the middle value.
76
10kΩ
100kΩ
2010 ~9990 MΩ
Accuracy:Fixed at the state of 23℃±5℃、45~75%RH
MODEL 8505
±(2%of rdg.+3digit)
10kΩ
180 ~1000 MΩ
2000 MΩ
±30%of rdg.
※
20.10~49.90MΩ
DC 500V
DC1000V
±(2%of rdg.+3digit)
10kΩ
5MΩ
201.0~499.0MΩ
2000 MΩ
1kΩ
±30%of rdg.
1.80~20.00MΩ
18.0~100.0MΩ
200.0MΩ
±(2%of rdg.+3digit)
10kΩ
201.0~999.0MΩ
2.000MΩ
1kΩ
Accuracy
10kΩ
18.0~100.0MΩ
200.0MΩ
Resolution
・Judgment test results
Judgment method
Setting range
Judgment conditions
・Test time
Setting range
Setting resolution
Accuracy
Response speed
・Mask time
Setting range
:Upper and lower limit digital comparator
:0.001~9.999 /10.00~99.99/100.0~999.9/1000~9990
:Upper limit setting>Insulation resistance value>Lower limit setting ・・・ GOOD
Upper limit setting ≦ Insulation resistance value ・・・・・・・・・・・・・・・・・・・ HIGH NG
Lower limit setting ≧ Insulation resistance value・・・・・・・・・・・・・・・・・・・・ LOW NG
:0.2~99.9 seconds
:0.1 seconds
:Setting value ± (0.1% +20ms)
During test
Display remaining time
Test end time Display remaining time
Waiting time Display setting value
Display response and judgment time
Auto range 0.4 seconds (in the middle value)
Fixed range 0.2 seconds (in the middle value)
Note)In case of the test object with large
ground capacitance, the resistance
value measured may become low
with the elapse of time.
For setting the appropriate time,
confirm sufficiently the time to
stabilize the measurement value
and set the test time so that there is
no wrong judgment.
:0.1~99.9 seconds
Mask time setting < Test time
:0.1 seconds
:Setting value ± (0.1% +20ms)
Setting resolution
Accuracy
・Discharging function
It is the function to discharge the electric charge which has been charged in the test specimen during insulation test.
Memory operation
Memory contents
Number of pieces
Memory retention
Readout the memory
Setting method
:Memorize the test conditions of withstand voltage test and insulation resistance test
:16 pieces
:Stored in a non-volatile memory
Memory period 10years
:Key operation, remote I/O connector, RS-232C, USB
:Key operation, RS-232C, USB
Program operation
Memory contents
Number of pieces
Number of steps
Memory retention
Read out memory
Setting method
:In withstand voltage test, the test conditions can be set in steps and a continuous test is possible.
:16 pieces (0~F)
:16 pieces (0~F)
:Stored in a non-volatile memory.
Memory period 10years
:Key operation, remote I/O connector, RS-232C, USB
:Key operation, RS-232C, USB
STEP 0
STEP 1
STEP 2
STEP 3
Test voltage
15
Elapsed time
MODEL 8505
77
15.Specifications
Other functions
Interlock
Key lock
Buzzer
Other functions
:When the rear connector pin is open, it is in locked state.
:Depending on the switch operation, it is a function to prohibit switch operation other than key lock.
:Function to ring the buzzer as per the judgment content (OFF setting possible)
:① Double action start
After STOP input is off, START signal is valid for 0.5 seconds.
② GOOD hold function
3 conditions can be selected.
0:”GOOD” judgment is output for 0.2 seconds and then returns to the READY state.
1:”GOOD” judgment is retained, after stop signal output, re-started by start signal.
2:”GOOD” judgment is retained, without stop signal, re-started by start signal.
③ Momentary start function
START signal performs test during on period.
④ Fail mode function
The function to limit the release of NG and PROTECTION to the STOP key of the tester.
⑤ NG Start
ON:The start of the test is performed by START signal even when NG judgment is not released
by STOP.
OFF:After the end of the judgment, NG judgment is retained, released by STOP and the test is
started by START signal.
Input Output signal
:36P Amphenol connector
:Open collector DC30V 30mA MAX
:TEST
:During the test period
END
:The end
TEST/H.V.OUT :During high voltage output
READY
:In waiting
ACW-TEST
:During withstand voltage test
IR-TEST
:During insulation resistance test
GOOD
:Pass judgment time (0.2s/continuous switchable)
NG
:Fail judgment time (continuous)
ACW HIGH
:Withstand voltage upper limit judgment time (continuous)
ACW LOW
:Withstand voltage lower limit judgment time (continuous)
ACW GOOD
:Withstand voltage pass judgment time
IR HIGH
:Insulation upper limit judgment time (continuous)
IR LOW
:Insulation lower limit judgment time (continuous)
IR GOOD
:Insulation pass judgment time
PROTECTION :Protection function operation
Output signal power supply :DC24V、0.1A
Input signal
:H=16.8~24V、L=0~3.8V
Ic=10mA、Llabel minimum pulse width=40ms
Input signal name
:START
STOP
INTER LOCK
ACW-MODE
IR-MODE
REAR MODE
Connector
Output signal
Output signal name
MODEL 8505
78
REMOTE I/O connector
Signal name
Pin name
Signal name
+24V
1
19
COM
NC
2
20
REAR MODE
START
3
21
ACW-MODE
STOP
4
22
IR-MODE
INTERLOCK
5
23
COM
MEM SET1
6
24
ACW-TEST
MEM SET2
7
25
IR-TEST
MEM SET4
8
26
TEST
MEM SET8
9
27
MEM SET10
TEST/H.V.OUT
10
28
END
READY
11
29
NC
PROTECTION
12
30
NC
GOOD
13
31
NG
ACW HIGH
14
32
ACW LOW
ACW GOOD
15
33
NC
IR HIGH
16
34
IR LOW
IR GOOD
17
35
NC
NC
18
36
COM
RS-232C・USB Interface
・Function
・Connector
・Transmission system
・Transmission speed
・Data length
・Parity
・Utility software
:Output the setting of the test conditions and test result data.
:D-Sub 9P
:Asynchronous method
:9600 / 19200 / 38400 bps
:8bit
:None/ even/ odd
:Optional
■USB Interface
・Specification
・Connector
・Utility software
:USB 1.1(HID)
:B type
:Optional
15
MODEL 8505
79
15.Specifications
General specification
・Power supply
・Power supply voltage
tolerance range
・Power consumption
:AC100V ~240V 50/60Hz
:AC90V~250V
:
Power consumption
power supply
100V
Waiting time
Maximum load
About 30VA
About 180VA
200V
About 60VA
About 200VA
・Operating temperature range :0~40℃
・Operating humidity range :20~80%RH (Non-condensing)
・Storage temperature
:-20~70℃
・Withstand voltage
:Power terminal - Between outer box AC1350V 1 minute
・Weight
:About 10kg
・Accessories
:High voltage cable 2m
1 piece
Earth wire
3m
1 piece
Power cord
2.5m
1 piece
Remote I/O plug
1 piece
Instruction manual (This book)
1 part
RS-232C・USB Interface manual 1 part
・Option
:Key cover
:5858-19
Rack mounting bracket
:5871-03-018
Power cord for AC200V 3m :5880-23-030
(For Europe 2pole earth with type)
19
φ5.3
2-φ4.8
19
Setting of the default value
Initialize this tester
Hold down the 
,

and
▼
keys (①) and turn on the POWER switch.
TEST VOLTAGE and CURRENT/RESISTANCE displays firmware version.
After 3 seconds, DANGER and JUGDE lamp is off and this tester is initialized.
When the initialization is run, various settings such as test conditions and data that have been saved
become the initial value as shown below.
DANGER
GOOD
GOOD
mA
HIGH
HIGH
HIGH
MΩ
LOW
L OW
LO W
1
Defautl value
Test mode Withstand voltage test conditions ACW
Test voltage
ACW-IR
0.00kV
Test voltage range
25V
Upper limit judgment value
10.00mA
Resistance range
AUTO
Lower limit judgment value
OFF
Upper limit resistance value
OFF
Voltage rise time
0.1s
Lower limit resistance value 0.001MΩ
Voltage fall time
OFF
Mask timer time
0.1s
Test time
60.0s
Test time
0.2s
Frequency of the test voltage 50Hz
MODEL 8505
Insulation resistance test conditions IR
80
Other functions
Functions
Setting value
Double action
Contents
0
Not set
Re-start with no stop signal and
GOOD hold
2
Momentary start
0
Not set
FAIL mode
0
Not set
NG start
hold judgment
1
Setting of the buzzer
ON
Pass judgment time
OFF
Fail judgment time
ON
Interlock
ON
Memory operation(No.1~No.16 Common)
Test mode
ACW-IR
Withstand voltage test conditions ACW
Insulation resistance test conditions IR
Test voltage
0.00kV
Test voltage range
25V
Upper limit judgment value
10.00mA
Resistance range
AUTO
Lower limit judgment value
OFF
Upper limit resistance value
OFF
Voltage rise time
0.1s
Lower limit resistance value
0.001MΩ
Voltage fall time
OFF
Mask timer time
0.1s
Test time
60.0s
Test time
0.2s
Frequency of the test voltage 50Hz
Program operation(No.1~No.F common)
It shows the setting value per program.
STEP
STEP
No. ON/OFF
Test
voltage
(kV)
Upper limit
judgment
value (mA)
Lower limit
judgment
value (mA)
Timer
time
(s)
Frequency of
the test voltage
(Hz)
50
0
1
2
3
4
5
6
END
END
END
END
END
END
END
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.50
0.50
0.50
0.50
0.50
0.50
0.50
OFF
OFF
OFF
OFF
OFF
OFF
OFF
0.1
0.1
0.1
0.1
0.1
0.1
0.1
7
↓
F
END
0.00
0.50
OFF
0.1
Depends on the
frequency of
STEP 0
15
MODEL 8505
81
15.Specifications
262
Exhaust exit(exhaust fan)
380
94min
Dimensions
71.5
200
Key cover (option)
310max
300
150max
134
25max
Suction inlet
MODEL 8505
82
MEMO
Feel free to use this page as a memo. Use this page freely as a memo.
For program operation
Step number
0
Each step specification
Next
step
Test
voltage
(kV)
Timer
Time
(s)
Upper limit Lower limit
judgment
judgment
value
value
(mA)
(mA)
Remarks
ON
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
END
15
MODEL 8505
83
MODEL
8505
Tsuruga Electric Corporation
Osaka Headquarters
1-3-23, Minamisumiyoshi, Sumiyoshi-ku, Osaka, Japan 〒558-0041
TEL 81-6 -6692-6700, FAX 81-6 -6609- 8115
E-mail: cs.info@tsuruga.co.jp
Yokohama Office
1-29-15, Shinyokohama, Kohoku-ku, Yokohama, Kanagawa, Japan 〒222-0033
Tokyo Office
5-25-16, Higashigotanda, Shinagawa-ku, Tokyo, Japan 〒141-0022
Nagoya Office
Sun Park Higashi Betsuin Bld. 2F
5-19, Oicho, Naka-ku, Nagoya, Aichi, Japan 〒460-0015
Osaka Plant
1-3-23, Minami Sumiyoshi, Sumiyoshi-ku, Osaka, Japan 〒558-0041
Shiga Plant
122, Kawasaki-Cho, Nagahama, Shiga, Japan 〒526-0846
www.tsuruga.co.jp
#
MODEL 8505
RS-232C・USB
Interface
Instruction Manual
I-02272
Table of contents
1.External interface ......................................................................................... 1
RS 232C Interface .................................................................................................................................. 1
2.Connection .................................................................................................... 2
Connector and signal .............................................................................................................................. 2
Connection to the host (Reference) .......................................................................................................... 2
3.Setting of this tester to communicate ........................................................... 3
Setting items........................................................................................................................................... 3
Setting method........................................................................................................................................ 3
4.Before the communication ........................................................................... 4
5.Structure of command and response ........................................................... 5
Structure of Command ............................................................................................................................ 5
Structure of response............................................................................................................................... 5
Response time ........................................................................................................................................ 5
6.Command list................................................................................................ 6
7.Individual command description ................................................................. 7
8.Error code and solution tips ........................................................................20
1.External interface
RS 232C Interface
Specification
Even if STOP command and STOP switch are pressed, judgment result of transmission buffer and data
are retained till the next start.
Transmission method
Asynchronous Full 2fold
Transmission speed
9600bps,19200bps,38400bps
Data bit length
8-bit
Stop bit
1-bit
Parity bit
None, odd, even
Delimited
CR+LF
Xon/Xoff
None
Receive buffer length
1000 bytes
Connector
D-sub9 pin(male)
Specification of USB
Specification
USB1.1
Class
HID class
Connector
Type B
Note: Cannot be used simultaneously with RS-232C.
RS-232C・USB for MODEL 8505
1
2.Connection
Connector and signal
This tester connector D sub 9 pin (male)
1 Pin
Pin no.
Signal n o.
Host side: D sub connector 9 pin (female)
Female side
Male side
Directi on
Name
Unused
①
②
RD (RXD)
←Host
Received data
③
SD (TXD)
→Host
Transmitted data
④
NC
Unused
⑤
SG (GND)
Signal ground
⑥
NC
Unused
⑦
NC
Unused
⑧
NC
Unused
⑨
NC
Unused
1 Pin
Recommended connector:
XM3D-0921(OMRON)
Recommended hood:
XM2S-0913(OMRON)
Inch screw
Note)External connector and cable, Model
5881-11-018、9 pin-9 pin/1.8m
(optional) are also available.
Connection to the host (Reference)
Connection cable :Use a cross cable 5881-11-018.
(If the cable other than the specified is used, there may be the case of communication failure.
Connection of cable
RS-232C・USB for MODEL 8505
8505
Pin no.
①②③④⑤⑥⑦⑧⑨
①②③④⑤⑥⑦⑧⑨
Host side
Pin no.
2
3.Setting of this tester to communicate
Setting items
Match the setting of ⓐ and ⓑ with communication equipment.
When test is to be performed by communication, set ⓒ with 「1」.
Setting item
ⓐ
9600bps
0
Transmission
19200bps
1
speed
38400bps
2
ⓑParity
None
0
Odd
1
Even
2
Start the test from front panel switch or remote I/O
0
Start the test depending on START command
1
ⓒSTART
Factory shipment
Setting no.
time
○
○
○
(in REMOTE state)
Setting method
2
8
7
6
a b c
3
5
Enter in the setting
2
4
3
5
1
① Press SET key (SET holding SHIFT) for 3 seconds in READY state.
・TIME display blinks the light.
② Using

and

key, “” is selected.
③ Enter in the setting using ▼
key.
・Setting conditions in TEST VOLTAGE display blinks the light.
Selection of each item
End of the setting
④ Using

and

⑤ Using
▲
and
▼
keys, ⓐTransmission speed ⓑParity and ⓒSTART are selected.
keys, the contents of each item are selected.
⑥ When ENTER key is pressed, the setting is stored and returns to READY state.
⑦ When EXIT key (EXIT holding SHIFT) is pressed, the setting is interrupted and becomes the
Interruption of the setting
READY state.
The setting content of that time is the condition that is before entering the
setting.
Start of the test
⑧ Pressing the REMOTE key, the test is started depending on the START command.
RS-232C・USB for MODEL 8505
3
4.Before the communication
! Caution
If the command is to be transmitted, make the interlock state in advance.
Avoid to perform key operation setting of this tester and communication setting simultaneously.
Refer to 8505 Instruction manual “3. Panel operation” of this tester for operation method of the
key lock.
RS-232C・USB for MODEL 8505
4
5.Structure of command and response
Structure of Command
Command
Example
WVOLT=
1.Command
Delimiter
Parameter

5.00kV
Command to control 8505
Upper case and lower case does not matter during command.
It means there is a break in transmitted data.
2.Delimiter
3.Command, parameter and delimiter use JIS8 bit code.
4.In case there is no parameter, transmit the delimiter following the command.
[Example] START 
5.Even if the unit of the parameter is not included, 8505 responses.
Caution during command transmission
Transmit setting command(○○○○=)when 8505 is in READY state.
When setting command is transmitted by the host during the test, 8505 transmits to host the “TEST”
for the test period.
Structure of response
In 8505, when command is transmitted to the host, it performs the analysis and processing and returns
the response.
When the received data is incompatible, 8505 returns an error code to the host.
Refer to the tips of the error code and solution for detail.
[When setting and operation command is valid]
○ For valid setting and operation command, ERROR=0 is always returned to the host.
Example
Valid command :In case of START
Response :ERROR=0
[When setting and operation command is invalid]
○ For invalid setting and operation command, ERROR=error code is always returned to the host.
Example Invalid command :STAT・・・when there is a mistake in spelling during test interruption
Response :ERROR=1
Response time
As the response time of command list of next page is the reference value, it changes depend
ing on the condition of use.
The performance of 8505 is not guaranteed.
Host
Command 
8505
Response 
Response time
RS-232C・USB for MODEL 8505
5
6.Command list
Description
Command
Reading the device information
Reading of the state
Remote control
Key lock
Start of the test
Discontinuation of the test, Judgment reset
Setting mode
Withstand voltage test
Test voltage
Upper limit judgment value
Setting
Reading
Setting
Reading
IDNT?
STATUS?
REMOTE=
REMOTE?
KEYLOCK=
KEYLOCK?
7
7
7
7
8
8
Setting
Reading
START
STOP
MODE=
MODE?
8
8
8
8
Setting
Reading
WVOLT=
WVOLT?
8
9
Setting
WHIGH=
9
Reading
WHIGH?
9
Setting
WLOW=
9
Reading
WLOW?
9
Setting
Reading
Setting
WTIMER=
WTIMER?
WRTIMER=
9
9
9
Reading
WRTIMER?
9
Voltage fall time
Setting
WFTIMER=
10
Reading
WFTIMER?
10
Frequency
Setting
WFREQ=
10
Reading
Setting
Reading
Setting
WFREQ?
IVOLT=
IVOLT?
IRANGE=
10
10
10
10
Reading
Setting
Reading
IRANGE?
IHIGH=
IHIGH?
10
11
11
Lower limit judgment value
Setting
Reading
ILOW=
ILOW?
11
11
Mask time
Setting
Reading
IMASK=
IMASK?
11
11
Test time
Setting
Reading
Reading
Setting
Reading
Setting
Reading
Setting
Reading
ITIMER=
ITIMER?
DATA?
SET=
SET?
MEMORY=
MEMORY?
MEM□=
MEM□?
11
11
12
14
14
15
15
15
16
Setting
Reading
Setting
Reading
Reading
PROGRAM=
PROGRAM?
PROG□=
PROG□?
PROGDATA?
16
16
17
18
19
Lower limit judgment value
Test time
Voltage rise time
Insulation resistance
test
Page
Test voltage
Resistance range
Upper limit judgment value
Reading of test result and data in a bulk
Panel setting mode test conditions
Switching of memory No.
1~16
Test conditions of memory
1~16
Switching of program No.
0~F
Test conditions of program
0~F
Reading of program and test result in a bulk
RS-232C・USB for MODEL 8505
6
Response
time
About
15ms
7.Individual command description
1)
IDNT?
Reading of the device information
Syntax
IDNT?
Transmission IDNT?
Response
2)
STATUS?
IDNT=①,②,③
① Maker name
② Model name
③ Software version
TSURUGA
8505
883-100 (Example)
Reading of the 8505 state
Syntax
STATUS?
Transmission STATUS?
Response
STATUS=①,②,③,④
Types of parameters
Weight of the data
① ② ③ ④
Parameter
Output signal name
Under test
0
0
0
0
0
0
0
0
0
1
2
4
TEST
END
TEST/H.V.OUT
Test end
Under high voltage output
0
0
0
8
READY
READY state
0
0
0
0
0
0
0
0
0
1
1
2
4
8
0
0
0
0
0
0
ACW-TEST
IR-TEST
GOOD
NG
ACW HIGH
0
2
0
0
ACW LOW
0
4
0
0
ACW GOOD
Under withstand voltage test
Under insulation resistance test
Pass judgment
Fail judgment
Withstand voltage test upper limit
judgment
Withstand voltage test lower limit
judgment
Withstand voltage test pass
0
8
0
0
IR HIGH
1
0
0
0
IR LOW
2
4
0
0
0
0
0
0
IR GOOD
PROTECTION
Insulation resistance test upper
limit judgment
Insulation resistance test lower
limit judgment
Insulation resistance test pass
Protection operation function
Response example
Example1
STATUS=0025 
IR-TEST+TEST+TEST/H.V.OUT
Under insulation resistance test, under test, under high voltage output
Example2
3)
REMOTE=
4) REMOTE?
STATUS=2442 
IR GOOD+ACW GOOD+GOOD+END
Insulation resistance test pass, withstand voltage test pass, pass judgment, Test end
Set the remote control
Syntax
REMOTE=[ON/OFF]
Transmission REMOTE=[ON/OFF]
Reading of the remote control state
Syntax
REMOTE?
Transmission REMOTE?
Response
RS-232C・USB for MODEL 8505
REMOTE=ON 
REMOTE=OFF 
7
5)
KEYLOCK=
Set the key lock
Syntax
KEYLOCK=[ON/OFF]
Transmission KEYLOCK=[ON/OFF] 
6)
KEYLOCK?
Reading of the key lock state
Syntax
KEYLOCK?
Transmission KEYLOCK? 
Response
KEYLOCK=ON 
KEYLOCK=OFF 
7)
START
Test is started in READY state.
Syntax
START
Transmission START 
Besides READY state, when RS-232C function setting of external control is START”0”, ERROR=6 is
returned.
8)
STOP
Discontinuation of the test. When run in the state of judgment issued, returns to the READY state.
Syntax
STOP
Transmission STOP 
9)
MODE=
Set the test mode
Syntax
MODE=[Parameter]
[Parameter]
ACWIR: Withstand voltage test → Automatic continuous test mode of
insulation resistance test
IRACW: Insulation resistance test → Automatic continuous test mode of
withstand voltage test
ACW:
Individual test mode of withstand voltage test
IR:
Individual test mode of insulation resistance test
PROG: Program operation
MEM:
Memory operation
Transmission MODE= ACWIR 
Test mode a withstand voltage test → Setting of automatic continuous test mode of insulation
resistance test.
10)
MODE?
Reading of the set test mode contents.
Syntax
MODE?
Transmission MODE?
Response
11)
WVOLT=
MODE=[Parameter]
[Parameter]
ACWIR: Withstand voltage test → Automatic continuous test mode of
insulation resistance test
IRACW: Insulation resistance test → Automatic continuous test mode
of withstand voltage test
ACW:
Individual test mode of withstand voltage test
IR:
Individual test mode of insulation resistance test
PROG: Program operation
MEM:
Memory operation
Set the test voltage of withstand voltage test.
Syntax
WVOLT=[Parameter]
[Parameter]:0.00kV~5.50kV
Transmission WVOLT=5.00kV 
Set the test voltage of withstand voltage test to 5.00kV.
RS-232C・USB for MODEL 8505
8
Individual command description
12)
WVOLT?
Reading of the test voltage of withstand voltage test.
Syntax
WVOLT?
Transmission WVOLT?
Response
13)
WHIGH=
WVOLT=[Parameter]
[Parameter]: 0.00kV~5.50kV
Set the upper limit judgment value of withstand voltage test.
Syntax
WHIGH=[Parameter]
[Parameter]: 0.01mA~20.00mA
Transmission WHIGH=10.00mA 
Set the upper limit judgment value of withstand voltage test to 10.00mA.
14)
WHIGH?
Reading of the upper limit judgment value of withstand voltage test.
Syntax
WHIGH?
Transmission WHIGH?
Response
15)
WLOW=
WHIGH=[Parameter]
[Parameter]:0.01mA~20.00mA
Set the lower limit judgment value of withstand voltage test.
Syntax
WLOW=[Parameter]
[Parameter]: Set to OFF or 0.01mA~19.99mA.
Transmission WLOW=2.00mA 
Set the lower limit judgment value of withstand voltage test to 2.00mA.
16)
WLOW?
Reading of the lower limit judgment value of withstand voltage test.
Syntax
WLOW?
Transmission WLOW?
Response
17)
WTIMER=
WLOW=[Parameter]
[Parameter]: OFF or 0.01mA~19.99mA
Set the test time of withstand voltage test.
Syntax
WTIMER=[Parameter]
[Parameter]: Set to OFF or 0.1s~99.9s/100s~999s.
Transmission WTIMER=60.0s 
Set the test time of withstand voltage test to 60.0 seconds.
18)
WTIMER?
Reading of the test time of withstand voltage test is done.
Syntax
WTIMER?
Transmission WTIMER?
Response
19)
WRTIMER=
WTIMER=[Parameter]
[Parameter]:OFF or 0.1s~99.9s/100s~999s
Setting of the voltage rise time of withstand voltage test.
Syntax
WRTIMER=[Parameter]
[Parameter]: Set to 0.1s~99.9s/100s~999s
Transmission WTIMER=10.0s 
Set the rise time of the withstand voltage test to 10.0 seconds.
20)
WRTIMER?
Reading of the voltage rise time of the withstand voltage test.
Syntax
WRTIMER?
Transmission WRTIMER?
Response
WRTIMER=[Parameter]
[Parameter]:0.1s~99.9s/100s~999s
RS-232C・USB for MODEL 8505
9
21)
WFTIMER=
Setting of the voltage fall time of withstand voltage test.
Syntax
WFTIMER=[Parameter]
[Parameter]: Set to OFF or 0.1s~99.9s/100s~999s.
Transmission WFTIMER=60.0s 
Set the test time of withstand voltage test to 60.0 seconds.
22)
WFTIMER?
Reading of the voltage fall time of the withstand voltage test.
Syntax
WFTIMER?
Transmission WFTIMER?
Response
23)
WFREQ=
WFTIMER=[Parameter]
[Parameter]: OFF or 0.1s~99.9s/100s~999s
Setting of the test voltage frequency of withstand voltage test.
Syntax
WFREQ=[Parameter]
Transmission WFREQ?
Response
24)
WFREQ?
WFREQ=[Parameter]
[Parameter]:50Hz or 60Hz
Reading of the test voltage frequency of withstand voltage test.
Syntax
WFREQ?
Transmission WFREQ?
Response
25)
IVOLT=
WFREQ=[Parameter]
[Parameter]:50Hz or 60Hz
Setting of the test voltage of insulation resistance test.
Syntax
IVOLT=[Parameter]
[Parameter]:25V,50V,100V,250V,500V,1000V
Transmission IVOLT=1000V 
Set test voltage of insulation resistance test to 1000V.
26)
IVOLT?
Reading of the test voltage of insulation resistance test.
Syntax
IVOLT?
Transmission IVOLT?
Response
27)
IRANGE=
IVOLT=[Parameter]
[Parameter]:25V,50V,100V,250V,500V,1000V
Setting of the resistance range of the insulation resistance test.
Syntax
IRANGE=[Parameter]
[Parameter]:
2.000MOHM, 20.00MOHM, 200.0MOHM, 2000MOHM, AUTO
Transmission IRANGE=AUTO 
Set the resistance range of insulation resistance test to auto range.
28)
IRANGE?
Reading of resistance range of insulation resistance test.
Syntax
IRANGE?
Transmission IRANGE?
Response
IRANGE=[Parameter]
[Parameter]:
2.000MOHM, 20.00MOHM, 200.0MOHM, 2000MOHM, AUTO
RS-232C・USB for MODEL 8505
10
Individual command description
29)
IHIGH=
Setting of the upper limit judgment value of insulation resistance test.
Syntax
IHIGH=[Parameter]
[Parameter]:OFF or 0.001MOHM~9990MOHM
Transmission IHIGH=100.0MOHM 
Set the upper limit judgment value of insulation resistance test to 100.0MΩ.
30)
IHIGH?
Reading of the upper limit judgment value of insulation resistance test.
Syntax
IHIGH?
Transmission IHIGH?
Response
31)
ILOW=
IHIGH=[Parameter]
[Parameter]:OFF or 0.001MOHM~9990MOHM
Setting of the lower limit judgment value of the insulation resistance test.
Syntax
ILOW=[Parameter]
[Parameter]: 0.001MOHM~9990MOHM
Transmission ILOW=0.2MOHM 
Set the lower limit judgment value of insulation resistance test to 0.2MΩ.
32)
ILOW?
Reading of the lower limit judgment value of the insulation resistance test.
Syntax
ILOW?
Transmission ILOW? 
Response
33)
IMASK=
ILOW=[Parameter]
[Parameter]:0.001MOHM~9990MOHM
Setting of the mask time of the insulation resistance test.
Syntax
IMASK=[Parameter]
[Parameter]:0.1~99.9s
Note)Mask time cannot be set more than test time (ITIMER).
Transmission IMASK=5.0s 
Set the mask time of insulation resistance test to 5.0 seconds.
34)
IMASK?
Reading of the mask time of insulation resistance test.
Syntax
IMASK?
Transmission IMASK?
Response
35)
ITIMER=
IMASK=[Parameter]
[Parameter]: 0.1~99.9s
Setting of the test time of the insulation resistance test.
Syntax
ITIMER=[Parameter]
[Parameter]: OFF or 0.2~99.9s
Note)Test time cannot be set less than mask time (IMASK).
Transmission ITIMER=60.0s 
Set the test time of insulation resistance test to 60.0 seconds.
36)
ITIMER?
Reading of the test time of the insulation resistance test.
Syntax
ITIMER?
Transmission ITIMER?
Response
RS-232C・USB for MODEL 8505
ITIMER=[Parameter]
[Parameter]: OFF or 0.2~99.9s
11
37)
DATA?
Reading of the test result.
Command used after the end of the test.
Syntax
DATA?
Transmission DATA?
Response
DATA=①,②,③,④,⑤,⑥,⑦,⑧,⑨,⑩
Test mode
ACW-IR or IR-ACW
ACW Individual test
IR Individual test
①
JUDGE=
JUDGE=
JUDGE=
②
WJUDGE=
WJUDGE=
IJUDGE=
③
WVOLT=
WVOLT=
RESISTANCE=
④
CURRENT=
CURRENT=
IMTIMER=
⑤
WMTIMER=
WMTIMER=
T(Types of timer at end time)
⑥
Types of timer at end time
Types of timer at end time
⑦
IJUDGE=
⑧
RESISTANCE=
⑨
IMTIMER=
⑩
T(Types of timer at end time)
Parameter
Contents
GOOD
Pass
NG
Fail
NULL
Interrupts the test by STOP
PROTECT
Protection function operates during test
GOOD
Pass
HIGH
Time of upper limit judgment
LOW
Time of lower limit judgment
NULL
Interrupts the test by STOP
HIGH LOW
Protection function operates during test
WVOLT=
0.00kV
Measured value of the test voltage
NULL
Interrupts the test by STOP
CURRENT=
0.00mA
Measured value of the leakage current
OVER
Measured value is over
JUDGE=
WJUDGE=
NULL
Interrupts the test by STOP
WMTIMER=
0.0s
Remaining time of the timer after test end
During WTIMER=OFF, Elapsed time
Types of timer
R
End with the rise time
T
End with the test time
F
End with the fall time
GOOD
Pass
HIGH
During upper limit judgment
LOW
During lower limit judgment
NULL
Abort the test with STOP
HIGH LOW
Protection function is operating during the test
1000MOHM
Insulation resistance measurement value (display
value)
OVER
Measurement value is over
UNDER
Measurement value is under
NULL
Abort the test with STOP
0.0s
Remaining time of the test
IJUDGE=
RESISTANCE=
IMTIMER=
RS-232C・USB for MODEL 8505
12
Synthetic
judgment
Withstand
voltage test
Insulation
resistance
test
Individual command description
Response example of “DATA?”
ACW Test
IR Test
ACW-IR Test
During GOOD judgment
DATA=JUDGE=GOOD,WJUDGE=GOOD,WVOLT=1.00kV,CURRENT=0.05mA,W
MTIMER=0.0s,F 
During HIGH judgment
DATA=JUDGE=NG,WJUDGE=HIGH,WVOLT=1.50kV,CURRENT=10.00mA,WMT
IMER=0.1s,T 
During test and when RESET
DATA=JUDGE=NULL,WJUDGE=NULL,WVOLT=NULL,CURRENT=NULL,WMT
IME=NULL,T
During occurrence of Protect
DATA=JUDGE=PROTECT,WJUDGE=HIGH LOW,
WVOLT=NULL,CURRENT=NULL,WMTIME=NULL,T
During GOOD judgment
DATA=JUDGE=GOOD,IJUDGE=GOOD,RESISTANCE=40.0MOHM,IMTIME=0.0s,
T
During LOW judgment
DATA=JUDGE=NG,IJUDGE=LOW,RESISTANCE=20.0MOHM,IMTIME=3.0s,T
During test and when RESET
DATA=JUDGE=DATA=JUDGE=NULL,IJUDGE=NULL,RESISTANCE=NULL,IM
TIME=NULL,T
During occurrence of Protect
DATA=JUDGE= PROTECT,IJUDGE=HIGH LOW,
RESISTANCE=NULL,IMTIME=NULL,T
During GOOD judgment
DATA=JUDGE=GOOD,WJUDGE=GOOD,WVOLT=0.12kV,CURRENT=0.57mA,W
MTIME=0.0s,F,IJUDGE=GOOD,RESISTANCE=0.205MOHM,IMTIME=0.0s,T
During ACW HIGH judgment
DATA=JUDGE=NG,WJUDGE=HIGH,WVOLT=2.10kV,CURRENT=10.18mA,WMT
IME=0.1s,R,IJUDGE=NULL,RESISTANCE=NULL,IMTIME=NULL,T
During IR LOW judgment
DATA=JUDGE=NG,WJUDGE=GOOD,WVOLT=0.12kV,CURRENT=0.57mA,WMTI
ME=0.0s,F,IJUDGE=LOW,RESISTANCE=0.205MOHM,IMTIME=3.0s,T
IR-ACW Test
During GOOD judgment
DATA=JUDGE=GOOD,WJUDGE=GOOD,WVOLT=0.12kV,CURRENT=0.57mA,W
MTIME=0.0s,F,IJUDGE=GOOD,RESISTANCE=0.205MOHM,IMTIME=0.0s,T
During IR LOW judgment
DATA=JUDGE=NG,WJUDGE=NULL,WVOLT=NULL,CURRENT=NULL,WMTIM
E=NULL,T,IJUDGE=LOW,RESISTANCE=0.205MOHM,IMTIME=3.0s,T
During ACW HIGH judgment
DATA=JUDGE=NG,WJUDGE=HIGH,WVOLT=2.10kV,CURRENT=10.18mA,WMT
IME=0.1s,R,IJUDGE=GOOD,RESISTANCE=0.205MOHM,IMTIME=0.0s,T
ACW-IR Test
or
IR-ACW Test
During test and when RESET
DATA=JUDGE=NULL,WJUDGE=NULL,WVOLT=NULL,CURRENT=NULL,WMT
IME=NULL,T,IJUDGE=NULL,RESISTANCE=NULL,IMTIME=NULL,T
During occurrence of Protect
DATA=JUDGE=PROTECT,WJUDGE=HIGH LOW,
WVOLT=NULL,CURRENT=NULL,WMTIME=NULL,T,
IJUDGE=HIGH LOW,RESISTANCE=NULL,IMTIME=NULL,T
※The data which cannot be tested becomes「NULL」.
RS-232C・USB for MODEL 8505
The test data which is ended by automatic test is retained.
13
38) SET=
Parameter of test conditions is set.
Command order, replacement not possible
Syntax
SET=
Transmission SET=①,②,③,④,⑤,⑥,⑦,⑧,⑨,⑩,⑪,⑫,⑬,⑭
Test mode
ACW-I or IR-ACW
ACW Individual test
IR Individual test
①
MODE=
MODE=
MODE=
②
WVOLT=
WVOLT=
IVOLT=
③
WHIGH=
WHIGH=
IRANGE=
④
WLOW=
WLOW=
IHIGH=
⑤
WTIMER=
WTIMER=
ILOW=
⑥
WRTIMER=
WRTIMER=
IMASK=
⑦
WFTIMER=
WFTIMER=
ITIMER=
⑧
WFREQ=
WFREQ=
⑨
IVOLT=
⑩
IRANGE=
⑪
IHIGH=
⑫
ILOW=
⑬
IMASK=
⑭
ITIMER=
For detail of each command, refer to the respective command descriptions.
Transmission example
SET=MODE=ACWIR, WVOLT=2.50kV,WHIGH=20.00mA,WLOW=OFF,
WTIMER=10.0s,WRTIMER=5.0s,WFTIMER=10.0s,WFRQ=60Hz,IVOLT=500V,
IRANGI=AUTO,IHIGH=OFF,ILOW=10.00MOHM,IMASK=1.0s,ITIMER=60.0s 
39)
SET?
Parameter of test conditions is read out.
Syntax
SET?
Transmission
SET?
Response
SET?=①,②,③,④,⑤,⑥,⑦,⑧,⑨,⑩,⑪,⑫,⑬,⑭
Test mode
ACW-IR or
ACW Individual test
IR Individual test
IR-ACW
①
MODE=
MODE=
MODE=
②
WVOLT=
WVOLT=
IVOLT=
③
WHIGH=
WHIGH=
IRANGE=
④
WLOW=
WLOW=
IHIGH=
⑤
WTIMER=
WTIMER=
ILOW=
⑥
WRTIMER=
WRTIMER=
IMASK=
⑦
WFTIMER=
WFTIMER=
ITIMER=
⑧
WFREQ=
WFREQ=
⑨
IVOLT=
⑩
IRANGE=
⑪
IHIGH=
⑫
ILOW=
⑬
IMASK=
⑭
ITIMER=
For detail of each command, refer to the respective command descriptions.
Response example
SET=MODE=ACWIR, WVOLT=2.50kV,WHIGH=20.00mA,WLOW=OFF,
WTIMER=10.0s,WRTIMER=5.0s,WFTIMER=10.0s,WFREQ=60Hz,IVOLT=500V,
IRANGE=AUTO,IHIGH=OFF,ILOW=50.00MOHM,IMASK=1.0s,ITIMER=60.0s 
RS-232C・USB for MODEL 8505
14
Individual command description
40) MEMORY=
41) MEMORY?
42) MEM□=
Setting of the Memory No.
Syntax
MEMORY=[Parameter]
[Parameter]:1~16
Transmission
MEMORY=5 
Memory No. is specified to「5」.
Memory No. is read out.
Syntax
MEMORY?
Transmission
MEMORY?
Response
MEMORY=8 
When memory No. 8 is read out
Test mode and parameter are set to the specified memory No. Command order replacement not possible
Syntax
MEM [Memory No.]=①,②,③,④,⑤,⑥,⑦,⑧,⑨,⑩,⑪,⑫,⑬,⑭,⑮
[Memory No.]: 1~16
Test mode
①
②
③
④
⑤
⑥
⑦
⑧
⑨
⑩
⑪
⑫
⑬
⑭
ACW-IR or
IR-ACW
MODE=
WVOLT=
WHIGH=
WLOW=
WTIMER=
WRTIMER=
WFTIMER=
WFREQ=
IVOLT=
IRANGE=
IHIGH=
ILOW=
IMASK=
ITIMER=
ACW Individual test
MODE=
WVOLT=
WHIGH=
WLOW=
WTIMER=
WRTIMER=
WFTIMER=
WFREQ=
IR
Individual test
MODE=
IVOLT=
IRANGE=
IHIGH=
ILOW=
IMASK=
ITIMER=
For detail of each command, refer to the respective command descriptions.
Transmission example
MEM3=MODE=ACWIR,
WVOLT=2.50kV,WHIGH=20.00mA,WLOW=OFF,
WTIMER=10.0s,WRTIMER=5.0s,WFTIMER=10.0s,WFREQ=60Hz,IVOLT=500V,
IRANGE=AUTO,IHIGH=OFF,ILOW=10.00MOHM,IMASK=1.0s,ITIMER=60.0s 
RS-232C・USB for MODEL 8505
15
43)
MEM□?
Test mode of memory No. and parameter is read out.
Syntax
MEM [Memory No.]?
[Memory No.]:1~16
Transmission MEM [Memory No.]?
Response
MEM [Memory No.]=①,②,③,④,⑤,⑥,⑦,⑧,⑨,⑩,⑪,⑫,⑬,⑭
Test mode
ACW-IR or
ACW Individual test
IR Individual test
IR-ACW
①
MODE=
MODE=
MODE=
②
WVOLT=
WVOLT=
IVOLT=
③
WHIGH=
WHIGH=
IRANGE=
④
WLOW=
WLOW=
IHIGH=
⑤
WTIMER=
WTIMER=
ILOW=
⑥
WRTIMER=
WRTIMER=
IMASK=
⑦
WFTIMER=
WFTIMER=
ITIMER=
⑧
WFREQ=
WFREQ=
⑨
IVOLT=
⑩
IRANGE=
⑪
IHIGH=
⑫
ILOW=
⑬
IMASK=
⑭
ITIMER=
For detail of each command, refer to the respective command descriptions.
Response example
MEM3=MODE=ACWIR, WVOLT=2.50kV,WHIGH=20.00mA,WLOW=OFF,
WTIMER=10.0s,WRTIMER=5.0s,WFTIMER=10.0s,WFREQ=60Hz,IVOLT=500V,
IRANGE=AUTO,IHIGH=OFF,ILOW=10.00MOHM,IMASK=1.0s,ITIMER=60.0s 
44)
PROGRAM=
Setting of the Program No.
Syntax
PROGRAM=[Program No.]
[Program No.]: 0~F
Transmission
PROGRAM=5 
Specify the program to「5」.
45)
PROGRAM?
Program No. is read out.
Syntax
PROGRAM?
Transmission
PROGRAM?
Response
PROGRAM=8 
When Program No.8 is read out.
RS-232C・USB for MODEL 8505
16
Individual command description
46)
PROG□=
Setting of the parameter of the specified program No.
Syntax
Command order replacement not possible
PROG[Program No.]=①,[STEP0], [STEP1], [STEP2], [STEP3], [STEP4], [STEP5],
[STEP6], [STEP7], [STEP8], [STEP9], [STEPA], [STEPB],
[STEPC], [STEPD], [STEPE], [STEPF]
[Program No.]: 0~F
①WFREQ=Test frequency(50Hz or 60Hz)
[STEP0]~[STEPF]:②,③,④,⑤,⑥,⑦
②STEP=0~F step No.
③WVOLT=Test voltage
④WHIGH=Upper limit judgment value
⑤WLOW=Lower limit judgment value
⑥WSTIMER=Application time
⑦(None) Then proceed to the next step.
END Program is ended with this step. The step after this will be invalid.
Transmission
PROG[Program No.]=①,[STEP0], [STEP1], [STEP2], [STEP3], [STEP4], [STEP5],
[STEP6], [STEP7], [STEP8], [STEP9], [STEPA],
[STEPB], [STEPC], [STEPD], [STEPE], [STEPF],END

Transmission example
Test voltage
0.00kV 1.00kV 2.00kV
3.00kV
Elapsed time
0.0s
0
STEP0
1
STEP1
STEP2
STEP3
2
3.0s
3
6.0s
STEP4
4
9.0s
STEP5
5
12.0s
STEP6
15.0s
6
Transmission
PROG5=WFREQ=60Hz,
STEP=0,WVOLT=1.00kV,WHIGH=10.0mA,WLOW=OFF,WSTIMER=0.1s,
STEP=1,WVOLT=2.00kV,WHIGH=10.0mA,WLOW=OFF,WSTIMER=3.0s,
STEP=2,WVOLT=3.00kV,WHIGH=15.0mA,WLOW=OFF,WSTIMER=0.1s,
STEP=3,WVOLT=3.00kV,WHIGH=15.0mA,WLOW=OFF,WSTIMER=3.0s,
STEP=4,WVOLT=2.00kV,WHIGH=10.0mA,WLOW=OFF,WSTIMER=3.0s,
STEP=5,WVOLT=2.00kV,WHIGH=10.0mA,WLOW=OFF,WSTIMER=3.0s,
STEP=6,WVOLT=0.00kV,WHIGH=10.0mA,WLOW=OFF,WSTIMER=3.0s,END,
RS-232C・USB for MODEL 8505
17
47)
PROG□?
Parameter of Program No. is read out.
Syntax
PROG[Program No.]?
Transmission
PROG[Program No.]?
Response
PROG[Program No.]=①,[STEP0], [STEP1], [STEP2], [STEP3], [STEP4],
[STEP5], [STEP6], [STEP7], [STEP8], [STEP9], [STEPA], [STEPB],
[STEPC], [STEPD], [STEPE], [STEPF]
Response example
Test voltage
0.00kV 1.00kV
2.00kV
3.00kV
Elapsed time
0.0s
0
STEP0
1
STEP1
STEP2
STEP3
2
3.0s
3
6.0s
STEP4
4
9.0s
STEP5
5
12.0s
STEP6
15.0s
6
PROG5=WFREQ=60Hz,
STEP=0,WVOLT=1.00kV,WHIGH=10.0mA,WLOW=OFF,WSTIMER=0.1s,
STEP=1,WVOLT=2.00kV,WHIGH=10.0mA,WLOW=OFF,WSTIMER=3.0s,
STEP=2,WVOLT=3.00kV,WHIGH=15.0mA,WLOW=OFF,WSTIMER=0.1s,
STEP=3,WVOLT=3.00kV,WHIGH=15.0mA,WLOW=OFF,WSTIMER=3.0s,
STEP=4,WVOLT=2.00kV,WHIGH=10.0mA,WLOW=OFF,WSTIMER=3.0s,,
STEP=5,WVOLT=2.00kV,WHIGH=10.0mA,WLOW=OFF,WSTIMER=3.0s,,
STEP=6,WVOLT=0.00kV,WHIGH=10.0mA,WLOW=OFF,WSTIMER=3.0s,END,
RS-232C・USB for MODEL 8505
18
Individual command description
48)
PROGDATA?
Test result of program operation is read out.
Syntax
PROGDATA?
Transmission
PROGDATA?
Response
PROGDATA=①,②,[STEP0], [STEP1], [STEP2], [STEP3], [STEP4], [STEP5],
[STEP6], [STEP7], [STEP8], [STEP9], [STEPA], [STEPB], [STEPC],
[STEPD], [STEPE], [STEPF]
①Program No. of 0~F
②WFREQ=Test frequency(50Hz or 60Hz)
[STEP0]~[STEPF]:③,④,⑤,⑥,⑦
③STEP= 0~F
④Success failure judgment : WJUDGE= GOOD
: WJUDGE= HIGH
: WJUDGE= LOW
: WJUDGE= NULL
: WJUDGE= HIGH LOW
⑤Set value of the test voltage:WVOLT=1.00kV
⑥Leakage current measurement value:CURRENT=0.00mA
⑦Elapsed time:WMTIMER=99.9s
Response example
Test voltage
0.00kV 1.00kV
2.00kV
3.00kV
Elapsed time
0.0s
0
STEP0
1
STEP1
STEP2
STEP3
2
3.0s
3
6.0s
STEP4
4
9.0s
STEP5
5
12.0s
STEP6
15.0s
6
Response
PROGDATA=5,WFREQ=60Hz,
STEP=0,WJUDGE=GOOD,WVOLT=1.00kV,CURRENT=2.00mA,WMTIMER=0.1s,
STEP=1,WJUDGE=GOOD,WVOLT=2.00kV,CURRENT=5.00mA,WMTIMER=3.1s,
STEP=2,WJUDGE=GOOD,WVOLT=3.00kV,CURRENT=10.00mA,WMTIMER=6.1s,
STEP=3,WJUDGE=GOOD,WVOLT=3.00kV,CURRENT=10.00mA,WMTIMER=6.2s,
STEP=4,WJUDGE=GOOD,WVOLT=2.00kV,CURRENT=5.00mA,WMTIMER=9.2s,
STEP=5,WJUDGE=GOOD,WVOLT=2.00kV,CURRENT=5.00mA,WMTIMER=12.2s,
STEP=6,WJUDGE=GOOD,WVOLT=0.00kV,CURRENT=0.00mA,WMTIMER=15.2s,
Note 1)If stopped by STOP, the data of the stopped step is output NULL.
Note 2)CURRENT=is the leakage current measurement value is output at the time of the end of the
STOP.
Note 3)WVOLT=is set value of test voltage is output.
RS-232C・USB for MODEL 8505
19
8.Error code and solution tips
Error code
ERROR=1
ERROR=2
ERROR=3
TEST
ERROR=6
ERROR=8
ERROR=9
Error contents and countermeasures
Command format cannot be recognized and the characters are also wrong.
Example)STAART、STAT
Correct the character string to START
Parameter is outside the valid range.
Example)ITIMER=9999
Put it in between 0.2~99.9
Trying to set the parameter in the condition where setting is not possible.
Example)When there is Err E-30 or Err E-31 on the front panel, it is a problem of the tester 8505 side and not
of the transmission.
Refer 「13.Error message」of the Instruction manual of this tester.
During test or judgment output, the operation other than STOP is performed.
During REMOTE=OFF, When START command is received.
Perform after REMOTE=ON setting.
Command transmission is performed during test conditions setting.
Example)Command transmission is not possible during setting by the front panel operation.
Let the setting end and the light on the READY lamp is in turned on condition.
Command is not appropriate.
Example)
・Even when the previous measurement is the test of PROGRAM operation, DATA? command is received.
・When the previous measurement is the test result other than the test of PROGRAM operation, PROGDATA?
command is received.
・Even when it is not yet measured, DATA? Or PROGDATA? command is received.
・Even when FAIL mode is ON, try to cancel NG and PROTECTION with STOP command.
Regarding protection function operation time(During interlock, error display)
PROTECTION state
ERR CHRG
Countermeasures
When the capacity of the test specimen is large, discharge is not possible and there is a case where
high voltage remains. When DATA? is received at this state, IJUDGE=PROTECT is returned to
the host. Besides, if STOP command is received then ERROR=3 is returned to the host.
Countermeasure
Leave it alone for some time and continue the discharge. When the discharge is completed, it is
possible that the STOP command or error display in STOP switch is released.
Even when command is sent in INTERLOCK state, ERROR=3 is returned to the host.
ERR LOCK
Countermeasure
Release the INTER LOCK and make STOP command or press STOP switch.
ERR E-11
ERR E-21
Cancel the momentary movements.
Refer the error contents in 「13.Error message 」of the instruction manual of this tester.
ERR E-30
It occurs during withstand voltage test, when the internal components are in the overheated state.
When DATA? is received at this state, WJUDGE=PROTECT is returned to the host. Besides, if
STOP command is received then ERROR=3 is returned to the host.
Countermeasure
There is a possibility of internal components getting overheated during the test for a long time. Wait
for a while at the power on state till the heat is dissipated. When the heat dissipation is completed, it
is possible that the STOP command or error display in STOP switch is released.
RS-232C・USB for MODEL 8505
20
RS-232C・USB for MODEL 8505
Tsuruga Electric Corporation
Osaka Headquarters
1-3-23, Minamisumiyoshi, Sumiyoshi-ku, Osaka, Japan 〒558-0041
TEL 81-6 -6692-6700, FAX 81-6 -6609- 8115
E-mail: cs.info@tsuruga.co.jp
Yokohama Office
1-29-15, Shinyokohama, Kohoku-ku, Yokohama, Kanagawa, Japan 〒222-0033
Tokyo Office
5-25-16, Higashigotanda, Shinagawa-ku, Tokyo, Japan 〒141-0022
Nagoya Office
Sun Park Higashi Betsuin Bld. 2F
5-19, Oicho, Naka-ku, Nagoya, Aichi, Japan 〒460-0015
Osaka Plant
1-3-23, Minami Sumiyoshi, Sumiyoshi-ku, Osaka, Japan 〒558-0041
Shiga Plant
122, Kawasaki-Cho, Nagahama, Shiga, Japan 〒526-0846
www.tsuruga.co.jp
Download PDF
Similar pages