Details Worksurface Rail Parts Step 1

Catalog All
Product Worksurface Rail Install
Date
(P-INSTRUCTWSR01)
03.01.12
1 of 3
Details
Worksurface rails allow accessories to be mounted beside a surface, without drilling into the finished top.
Worksurface rails may also be shared between surfaces.
Worksurface Rail Parts
2
1. Rail End Cap
2. Worksurface Rail
3. Slide Plate
4. Mounting Plate
5. 1/4-20 Flat Phillips Screw (3/8”)
6. Standard Surface Screws (1”)
3
4
5
#10-32 Flat Phillips Screw (3/8”)
6
3/8”
Standard Surface Screws (1”)
1”
Step 1
Install slide plates used with mounting the rail to the
bottom of worksurface. Install one slide plate per
mounting plate.
Note: Also install slide plates to be used with modesty
mounted screens at this time.
© 2012, AIS
Phone: 800.434.7400 Fax: 978.562.0811 Web: www.ais-inc.com
1
Catalog All
Product Worksurface Rail Install
(P-INSTRUCTWSR01)
Date
03.01.12
2 of 3
Details
Worksurface rails allow accessories to be mounted beside a surface, without drilling into the finished top.
Worksurface rails may also be shared between surfaces.
Step 2
Position slide plates as needed. Secure mounting plates
to slide plates using (2) #10-32 (3/8”) Flat Phillips Screws.
#10-32 Flat Phillips Screw (3/8”)
3/8”
Top Down View
Bottom Up view
Step 3
Standard Surface Screws (1”)
Position the Worksurface Rail as needed, and secure to
the surface using standard worksurface screws.
1”
© 2012, AIS
Phone: 800.434.7400 Fax: 978.562.0811 Web: www.ais-inc.com
Catalog All
Product Worksurface Rail Install
(P-INSTRUCTWSR01)
Date
03/01/12
3 of 3
Details
Worksurface rails allow accessories to be mounted beside a surface, without drilling into the finished top.
Worksurface rails may also be shared between surfaces.
Step 4
Install slide plates. Use one slide plate per accessory
connection point.
Once all slide plates are installed, install end caps on
rail. Slide the slide plates back and forth to position
accessories as needed.
Above is an example of the glass clamps being installed
on a worksurface rail.
Note that if the slide plates are not installed the screws
that secure the clamps (or other accessories) will not
have anything to screw into.
Finished Example
Below is an example of what an installed worksurface
rail would look like if in use with Calibrate universal frame
screens. To the right is an example of the worksurface
rail with up-mounted frameless glass.
© 2012, AIS
Phone: 800.434.7400 Fax: 978.562.0811 Web: www.ais-inc.com
Download PDF