User’s Guide
®
www.fetco.com
Models:
f
f
CBS-2131
CBS-2132
3 liter and 1 gallon airpot brewers
NOTICE TO INSTALLER: Please leave this book with the machine.
Table of Contents
Contact Information ........................................................2
Description & Features ...................................................2
Specifications..................................................................2
Requirements .................................................................2
Weights Capacities and Measurements.........................3
Electrical Configuration and Brewing Efficiency .............3
Installation.......................................................................5
Accessing batch and programming menu screens ........8
Operating Instructions...................................................10
Programming- operator access programming..............12
Hot water convenience tap ...........................................17
Adjustable spray pattern ...............................................17
Error Codes...................................................................17
Airpot use instructions and cleaning.............................18
Parts diagrams, bill of materials lists ............................22
Wiring diagrams............................................................33
FETCO®, LUXUS®, EXTRACTOR®, INTERMITTENT BREW, and Driven To Innovation™
are trademarks or trade names of Food Equipment Technologies Company.
© 2012 Food Equipment Technologies Company
Version1 September 2012
Contact Information
FETCO®
Food Equipment Technologies Company
600 Rose Road
Lake Zurich • IL • 60047-0429 • USA
Phone: (800) 338-2699 (US & Canada)
(847) 719-3000
Fax: (847) 719-3001
Email: sales@fetco.com
techsupport@fetco.com
Internet: www.fetco.com
Description & Features
The CBS-2130 Series coffee brewers feature our universal spray over technology, which works like this:
The following variables are programmed for each batch size:
™
Brew volume
™
Prewet percent (Percentage of the brew volume)
™
Brew time
™
Prewet delay (The time between prewetting and the brew cycle.)
™
Adjustable number of pulses
™
Bypass percent (Percentage of the brew volume)
™
Three selectable spray patterns
™
Drip delay (The time between the end of the brew cycle to
empty the brewbasket and end of the brewing cycle.)
Using these variables, the software calculates how much water to use for prewetting, bypass (optional), and
brewing. The total brew time is divided into several cycles. Within these cycles, the software calculates how
long to spray water over the coffee grounds, and how long to pause before the next cycle begins. The optional
bypass valve opens at the beginning of the brew cycle and dispenses the correct amount of water all at once.
Spray pattern into brew basket may be user set for perfect penetration.
Features
Touchscreen Operation
Cascading Spray Dome-no holes to clog in sprayhead
Four fully programmable batch sizes per side
Batch sizing
Customizable batch name
Recipe copy
Screen logo customizable by user from SD card
SD card firmware program and upgrade installation
User programs save to and load from SD cards
™
™
™
™
™
™
™
™
™
™
™
™
™
™
™
™
™
™
Pump circuit calibration on startup
Magnetic flux brew basket sensor
Dispenser locator under brew basket
Brew at temperature protection
Brew mechanism is digitally adjustable
Adjustable bypass (with bypass option)
Three adjustable spray patterns
Totalizing counters for brewer functions
Shipped ready to operate out of the box
Specifications
Requirements
™
™
™
Water Requirements:
CBS-2131: 20-75 psig (138-517kPa) 1½gpm/(5.7lpm)
CBS-2132: 20-75 psig (138-517kPa) 1½gpm/(5.7lpm)
Water inlet fitting is a 1/4 inch male flare.
™
Brew Volume:
Full Batch 3 liter CBS-2132 & CBS-2131—3 liter version
Full Batch 1gal. CBS-2132 & CBS-2131—1 gal. version
™
™
™
Inlet Water Temperature: Cold or Hot supply
Coffee Filter Size:
13”X5”– standard FETCO # F002
Electrical: See electrical configuration chart.
Temperature:
200°F (93°C) inside water tank (at sea level)
195°F (91°C) ± 5° at sprayhead
Designs, materials, specifications, physical dimensions, firmware and software protocol for equipment or replacement parts are subject to change by FETCO without notice.
2
Weights Capacities and Measurements
Weights and Capacities & Measurements; 3 liter and 1 gallon brewers
Brewer
Height
Width
Depth
Empty Filled
Weight Weight
CBS-2131
3 liter
21 ⅜”
54.3cm
11 ¾”
30.3cm
20 ⅜”
51.8cm
29 lb
13.1kg
CBS-2131
I gallon
23 ⅜”
59.4cm
11 ¾”
30.3cm
20 ⅜”
51.8cm
CBS-2132
3 liter
21 ⅜”
54.3cm
19 ¾”
50.2cm
CBS-2132
I gallon
23 ⅜”
59.4cm
19 ¾”
50.2cm
Total WeightBrewer &
Filled Dispenser
Shipping
Weight
Shipping Dimensions
50 lb
22.7 kg
61.2lb
27.8 kg
36.3 lb
16.5 kg
22 ¾”x 16 5/8” x 22 7/8”
57.8 x42.3x58.1cm
29 lb
13.1kg
50 lb
22.7 kg
63lb
28.6 kg
36.3 lb
16.5 kg
22 ¾”x 16 5/8” x 22 7/8”
57.8 x42.3x58.1cm
20 ⅜”
51.8cm
42.6lb
19.3 kg
87.6 lb
39.7kg
110lb
49.9 kg
49.4 lb
22.4 kg
24½” x 22⅞” x 23”
62.2 x 58.1 x 58.4cm
20 ⅜”
51.8cm
42.6lb
19.3 kg
87.6 lb
39.7 kg
114 lb
51.7 kg
49.4 lb
22.4 kg
24½” x 22⅞” x 23”
62.2 x 58.1 x 58.4cm
Electrical Configuration and Brewing Efficiency
Electrical Configurations- CBS-2131—3 liter version
Configuration
Heater
Code
Configuration
Bypass
Voltage
Phase
Wires
Electrical
Connection
KW
Maximum Amp
Draw
Gallon/Hour
(3 liters per batch)
E213103
1 X 1.5 kW
NO
100 - 120
1
2+G
NEMA 5-15P
1.1 – 1.6
10.9 – 13.0
3.9 gal/14.8 lit
E213104
1 X 1.7 kW
NO
100 - 120
1
2+G
NEMA 5-15P
1.3 – 1.8
12.3 - 14.7
4.4 gal/16.7 lit
E213101
1 X 2.3 kW
NO
100 - 120
1
2+G
NEMA 5-20P
1.7 – 2.4
16.5 - 19.7
5.8 gal/22 lit
E213105
1 X 2.3 kW
NO
200 - 240
1
2+G
Cord/No Plug
1.7 – 2.4
8.5 – 10.1
5.8 gal/22 lit
E213108
1 X 3.0 kW
NO
200 - 240
1
2+G
Cord/No Plug
2.2 – 3.1
10.9 – 13.0
7.7 gal/29.1 lit
.
Electrical Configurations- CBS-2132—3 liter version
Configuration
Code
Heater
Configuration
Bypass
Voltage
Phase
Wires
E213201
E213202
2 X 2.3 kW
2 X 3.0 kW
NO
NO
200-240
200-240
1
1
2+G
2+G
Electrical
Connection
KW
Terminal Block 3.3 – 4.7
Terminal Block 4.2 – 6.1
Maximum
Amp Draw
(3 liters per batch)
16.5 - 19.7
21.3—25.5
11.5 gal/43.5 lit
14.0 gal/53 lit
Gallon/Hour
.
Electrical Configurations- CBS-2131—1 gallon airpot version
Configuratio
n Code
Heater
Configuration
E213102
E213112
E213106
E213116
KW
Maximum
Amp Draw
(1 gallon per batch)
NEMA 5-20P
1.7 – 2.4
16.5 - 19.7
5.8 gal/22 lit
NEMA 5-20P
1.7 – 2.4
16.5 - 19.7
5.8 gal/22 lit
Cord/No Plug
1.7 – 2.4
8.5 – 10.1
5.8 gal/22 lit
Cord/No Plug
1.7 – 2.4
8.5 – 10.1
5.8 gal/22 lit
2+G
Cord/No Plug
2.2 – 3.1
10.9 – 13.0
7.7 gal/29.1 lit
2+G
Cord/No Plug
2.2 – 3.1
10.9 – 13.0
7.7 gal/29.1 lit
Bypass
Voltage
Phase
Wires
1 X 2.3 kW
NO
100 - 120
1
2+G
1 X 2.3 kW
YES
100 - 120
1
2+G
1 X 2.3 kW
NO
200 - 240
1
2+G
1 X 2.3 kW
YES
200 - 240
1
2+G
E213108
1 X 3.0 kW
NO
200 - 240
1
E213118
1 X 3.0 kW
YES
200 - 240
1
Electrical
Connection
Gallon/Hour
.
Electrical Configurations- CBS-2132—1 gallon airpot version
Configuration
Code
Heater
Configuration
Bypass
Voltage
Phase
Wires
E213203
E213213
2 X 3.0 kW
2 X 3.0 kW
NO
YES
200-240
200-240
1
1
2+G
2+G
Electrical
Connection
KW
Terminal Block 4.2 – 6.1
Terminal Block 4.2 – 6.1
Maximum
Amp Draw
(1 gallon per batch)
21.3—25.5
21.3—25.5
14.0 gal/53 lit
14.0 gal/53 lit
Gallon/Hour
Designs, materials, specifications, physical dimensions, firmware and software protocol for equipment or replacement parts are subject to review and change by FETCO without notice
3
Dimensions & Utility Connections—Rough-in drawings
CBS-2131
3 liter
Rough-in CBS-2131—Single station 3 liter airpot version
CBS-2132
3 liter
Rough-in CBS-2132—Twin station 3 liter airpot version
NEMA PLUG CONFIGURATION
G
W
NEMA 5-15P
CBS-2131
1 gallon
Rough-in CBS-2131—Single station 1 gallon airpot version
CBS-2132
1 gallon
Rough-in CBS-2132—Twin station 1 gallon airpot version
4
G
W
NEMA 5-20P
Installation
(For Qualified Service Technicians Only)
Guide to A Successful Installation
If not installed correctly by qualified personnel, the brewer will not operate properly and damage may result.
Damages resulting from improper installation are not covered by the warranty, and will void the warranty.
Here are the key points to consider before installation:
Electrical:
™ All FETCO brewers require an electrical ground wire. Installation without grounding is dangerous.
™ Verify voltages, polarity, circuits, and circuit breaker access before attaching equipment.
™ The electrical diagram is located in the Users Guide and online at www.fetco.com.
™ The installation must comply with applicable federal, state, and local codes having jurisdiction at your
location. Check with your local inspectors to determine what codes will apply.
Plumbing:
™ All installations must comply with applicable federal, state, or local plumbing codes.
™ An inline water filter is highly recommended. It should be installed after a water shutoff valve and in a
position to facilitate filter replacement.
™ The water line and newly installed filter cartage must be flushed thoroughly prior to connecting it to the
brewer to prevent debris from contaminating the machine.
™ Verify that the water line will provide a flow rate of at least 1½gpm/ (5.7lpm) per minute and water
pressure is between 20-75 psig (138-517kPa) before making any connections.
™ Install a backflow prevention device if required. Many municipalities require a recognized backflow
preventer. Usable on all hot beverage and cold beverage equipment is a WATTS® SD-2 or SD-3.
These spring loaded double check valve models are accepted by most zoning authorities.
The check valve should be as close to the water supply inlet of the beverage equipment as possible.
General:
™ Utilize only qualified beverage equipment service technicians for installation.
A Service Company Directory is available at www.fetco.com.
Utility slide
on back
of brewer
WARNING
Leveling legs, if installed, are to be
adjusted for leveling the brewer only.
Do not use for height adjustment, or extend
them higher than necessary.
Power
Switch
Electrical
Connection
Tank Drain
Water
Supply
Connection
Installation Instructions
Brewer Setup
1. Review the dimensions for the unit and verify that it will fit properly in the space intended for it. Verify that
the counter or table will support the total weight of the brewer and dispensers when filled (specifics-page
3).
2. Place the brewer on the counter or stand.
3. When the brewer is in position, level it front to back as well as side to side by adjusting the legs.
4. For 200-240 volt units: remove the lower utility slide out at the back of the equipment to access the
electrical connections. The utility slide must remain close to the unit, Note: it cannot be detached
completely.
5
Water Connection
1. Water inlet is a ¼ inch male flare fitting.
2. The brewer can be connected to a cold or hot water line. Cold water is preferred for best coffee flavor, but
hot water will allow for faster recovery times. High temperature water should not exceed 160°F/71°C.
3. Install a water shut off valve near the brewer to facilitate service. An in-line water filter should be used, it
should be installed after the water shut off valve and in a position to facilitate filter replacement.
4. Flush the water supply line and filter before connecting it to the brewer.
5. Verify that the water line will provide at least 1½gpm/(5.7lpm) per minute for the CBS-2131& CBS-2132 and
also that the water pressure is between 20-75 psig (138-517kPa).before connecting it to the brewer.
Electrical Connection – US & Canada
1. Verify that the actual voltage at the electrical service connection is compatible with the specifications on the
brewer’s serial number label. Install an electrical ground wire.
2. The temperature and water tank fill level are pre-set at the factory. There is no need to turn off the heaters
during the installation process. The heaters are disabled by the control board until the tank is full of water.
The heating process will start automatically when the tank has filled.
3. Most CBS-2131 equipment is factory equipped with a 120 V cord and plug. Some CBS-2131 and all CBS2132 have a terminal block for connecting the incoming power wires. Consult local codes to determine if a
cord and plug can be installed on factory supplied terminal block equipment, or if the unit must be hard
wired.
4. Plug in unit if the equipment has an attached cord & plug, or, wire into circuit for terminal block units. Note
that the plug is NEMA 5-15P or NEMA 5-20P (domestic).
5. A fused disconnect switch or circuit breaker on the incoming power line must be conveniently located near
the brewer, and its location and markings known to the operators.
6. The body of the brewer must be grounded to a suitable building ground. A ground lug is provided in the
brewer next to the power terminal block. Use 10 gauge copper wire for grounding.
7. Electrical connections must be secured in-place within the unit to meet national and local
standards.
WARNING—DANGER
Warning: To prevent
electrical shock, this
unit must be properly
grounded.
Do not plug-in or electrically
energize this equipment, or attempt
operation without all covers in place
and all screws fastened.
Electrical Configurations Terminal Block Diagram – US & Canada
CBS-2131
120 volt models
Factory Configuration:
Attached cord 120 VAC, 3 wires
GROUND
LUG
GROUND WIRE
!MUST BE INSTALLED!
L1
N
(some)CBS-2131 and (all)CBS-2132
208-240 volt models
Factory Configuration:
Terminal block for professional installation
L2
GROUND LUG
L1
N
L2
L2 - NOT USED
For 120 volt
CORD WITH
NEMA 5-15P or 5-20P
or without PLUG
GRO UND WIRE
!MUST BE INSTALLED!
120V
120V
N
NOT USED
208-240V
NEW FETCO CONFIGURATIION METHOD!
6
Final Setup
Final Setup
1. Turn on incoming water supply line and carefully inspect both inside and
outside of the brewer for leaks in all fittings and tubes
2. Turn on power.
3. Press the brewer’s main power switch (located on the lower right of the
back of the equipment)
4. Pre-check will display: "DC voltage calibration for pumps is
running…Please wait…Calibration is successfully done”. (15 seconds)
5. The water tank will begin filling. FETCO Home Screen #1 will read
“FILLING”.
6. When the water level rises and is sensed by the probe at the top of the
tank the heaters will activate
7. Heaters are automatically disabled until the tank is full.
FETCO Home Screen #1 “FILLING”
FETCO Home Screen #2 “HEATING”
8. While the water is heating Screen #2 “HEATING” will display and the
actual water temperature will be displayed.
9. After the water has reached the set temperature Screen #3 will display
“READY”
10. Review the Operating Instructions. Brew one full batch (water only) on
each side to confirm proper fill levels. The brewer is factory set with water
only (no coffee) to dispense the correct amount of water. If the actual
volume is slightly different from the programmed volume, fine tuning the
brewer may be necessary. See Calibrate Pumps in the OUTPUT section
in the PROGRAMMING section.
11. Re-attach the covers after one final inspection for leaks. Look closely in
the top of the brewer section at the dispense fittings during this
inspection.
Features of your FETCO Brewer
Touch-screen for brewer operation
Brew basket sensor (not accessible)
SD card interface port (Load & Save)
Hot Water Faucet
Locator removable for service access
Locator for airpot dispenser
(Two for CBS-2132)
Main power switch
Slide out back panel for service access
7
FETCO Home Screen #3 “READY
Accessing batch and programming menu screens
Accessing batch and programming menu screens
DC voltage calibration for pumps is running
Please wait…
Calibration is successfully done.
ÅFirst message on touchscreen display at powerup. This shows
only at “POWER ON”, when ON/OFF. The software is analyzing
and correcting any variations as a quality control feature.
Å FETCO home screen will display on completion
Batch selection and brew operation menu screens
Å Tap FETCO HOME SCREEN to enter batch selection screen.
Tap left or right side batchesÆ
Hold down batch selector pennant to begin brew.
FETCO home screen
Operation screens
Programming menu screens
Touchscreen
MAIN POWER SWITCH
Located to lower right
side of back panel
FETCO home screen
DC voltage calibration for pumps is running
Please wait…
Calibration is successfully done.
ÅFirst message on touchscreen display at powerup. This shows
only at “POWER ON”, when ON/OFF. The software is analyzing
and correcting any variations as a quality control feature.
Å FETCO home screen will display on completion
From power “OFF”ÆTurn main power switch to “ON”
Touch screen will illuminate, and pump voltage calibration will display
When Complete: FETCO HOME SCREEN will display
Immediately touch and hold finger to enter programming
In 5-8 seconds “PROGRAMMING” screen will appearÆ
8
Operator Training
Review the operating procedures with whoever will be using the brewer.
Pay particular attention to the following areas:
1. Always pre-heat the dispensers before the first use of each day by filling them half way with hot water, and
letting them stand for at least 5 minutes.
2. Don't remove the brew basket from a coffee brewer until it has stopped dripping.
3. Make sure the dispenser is empty before brewing into it.
4. Show how to attach covers, close, and or secure the dispensers for transporting.
5. Show the location and operation of the water shut off valve as well as the circuit breaker for the brewer.
6. Steam from the tank will form condensation in the vent tubes. This condensation will drip into and then out of
the brew baskets. Up to 1/4 cup/118cc discharging overnight is possible. Place an appropriate container
under each brew basket when not in use.
7. We recommend leaving the power to the brewer on overnight. The water tank is well insulated and very little
electricity is used to keep the tank hot. Leaving the brewer in the “ON” position will also avoid delays at the
beginning of shifts for the brewer to reach operating temperature.
Cleaning & Maintenance
After Each Brew:
1. Dispose of grounds and rinse brew basket.
2. Never strike a brewbasket or hit it against a hard surface.
This will damage the brew cone, and may damage the brewbasket support rails
3. Rinse dispensers before reuse.
Every Day:
1. Wash brew basket with hot sudsy water.
2. Pull CSD from the spray head, it is magnetically attached. Use gloves or a heavy towel. Æ
Wash off any film and reattach. Use vinegar if limescale filming is present.
3. Clean dispensers with hot suds water and a brush, rinse and air dry.
4. Use only a soft cloth and hot suds on the outside to avoid scratches. Never use abrasives
which will scratch surface.
Weekly
1. Use a commercial coffee dispenser cleaner such as URNEX™, TABZ™, DIP-IT™ or Squeak 'n Clean™.
2. Carefully Follow the instructions supplied with the cleaning product
3. Never use spray cleaners, solvent, solvent based cleaner or petroleum based polish anywhere on dispensers
1.
2.
3.
4.
5.
Safety notes
Professional installation is required. This appliance is manufactured for commercial use only.
Operation requirements and maintenance for commercial cooking appliances differ from household appliances.
Operators must be trained for this equipment and must understand the use, maintenance and hazards.
Do not attempt to move hot beverage equipment once it is filled. Drain equipment before moving.
CBS-2130 series coffee brewers prepare up to 3 liters/1 gallon of coffee or tea in a single batch using very hot
water. For safety, the brew basket is locked and may be serviced 5.5 minutes after starting the brew. The
factory set brew (default) time is 5.5 minutes with the brew basket locked for safety from start of brew.
! Æ Never attempt to defeat or override a brew basket locking feature.
Warning
Turn off power before any cleaning procedure, including wiping the exterior for appearance reasons.
Dry the exterior, especially the face panel, before turning on power.
Do not apply any type of spray cleaner on the face panel of this equipment.
Never use solvent or solvent-based cleaner or petroleum based polish anywhere on this equipment.
Dry the face of the touch pad before turning on power
6.
Do not electrically energize this equipment or attempt operation without all covers in place and all screws fastened.
1.
2.
3.
4.
5.
7. Unplug machine before disassembly or servicing.
9
Operating Instructions
ÆQuick brewer setup
NOTES
Install plumbing and electrical utilities.
-See Installation Section in this guide
Turn rear power switch “ON”.
-Located on back, lower right side
Brewer hot water tank will fill in 4-8 minutes.
-Ready screen will display ”▪FILLING”
Heater(s) activate when tank is full
-Ready screen will display ”▪HEATING”
Initial heating will be 15-30 minutes
-Place dispenser under brewbasket(s)
to collect any overflow and condensate
Tank displays “ ▪ READY” when filled & 200°F/93°C is reached
Brewer is ready to brew when “▪ READY” is displayed
-Best results if brewer remains “ON”
Brewing
ÆTo brew a single 3 liter coffee batch, using default recipe
NOTES
FETCO CBS-2130 series equipment is factory calibrated and preloaded with recipes and is ready to brew.
Place 13”X5” paper filter in brew basket
-FETCO Product # F002 or any 13”X5”
Add 3-8 ounces (85 – 227 g) of ground coffee
-Weights given are only suggested
Insert loaded brewbasket into brewer rails
-Brewbasket(s) must be in place
Have empty dispenser under brewbasket
-Use the convenient locator guide
Tap “▪ READY” screen to enter the batch selection menu
-A long duration “TAP” with fingertip
Touch a top batch key for “REGULAR 1”
-Touch batch pennant with fingertip
Brewer will brew and display the icon for the function step it is in
-Icon may be toggled for information
On dual side brewer, touch other side to access batches for brewing
-Right to left side switching by touch
Batch will complete brewing in 5 ½ minutes
-Brew time: 4 minutes+1½ min. drip out
Touch the “Ready” screen
anywhere briefly to activate
Touch and hold finger on
selection pennant for about two
seconds to start brew
(CBS-2131)
(CBS-2132)
CBS-2132 selection
for brewing on right,
left or both sides.
Touch batch pennant
to access menu
10
Brewing-shown by touchscreen
Brewer screens displayed for brewing
CBS-2131
CBS-2132
NOTES
“READY SCREEN”
Tap screen to display
menus
Note: there are three “BREW AT
TEMPERATURE DEFINITONS”. The “Brew
at temperature default routine is shown below.
Unit displays four
preprogrammed batch
buttons per side. CBS2132 has right and left
ÅCBS-2131
CBS-2132 Æ
Brew basket sensor
enabled.
Unit is brewable only when
brebasket is in place.
(option may be disabled by
user)
Select and hold one button
for 2 seconds
Brew at tempertaure
enabled: brew will start
when tank temperature
reaches he set point
Brew started
(in prewet)
ÅCBS-2131
CBS-2132 Æ
Both sides of CBS-2132
brewing simaltanously.
Brewing
Both sides of CBS-2132
brewing simaltanously.
ÅCBS-2131
CBS-2132 Æ
ÅCBS-2131
CBS-2132 Æ
Both sides of CBS-2132
brewing simaltanously.
Left side completing drip
delay
Brew completed
(in drip delay)
ÅCBS-2131
CBS-2132 Æ
CBS-2132 right side
completing drip delay, left
side ready for next brew
Brewing
11
Programming- operator access programming
-The FETCO CBS-2130 brewers have four brew batch menus per side.
They are preprogrammed with basic settings that will operate the equipment as purchased.
There are two batches each marked “Regular” and two marked “Decaf”
-Most operators prefer a full batch and half batch setting for regular and decaf or specialty coffees. These will need
to be programmed by the operator
-Settings are adjustable and the names can be changed. -Batch 1 & 4 cannot be disabled.
Accessing
Programming
Menu screen displayed
Accessing
Programming menu
screens
Menu screen displayed
Turn unit “OFF”
After 10 second delay:
Pre-check will display: "DC
voltage calibration for pumps is
running…Please wait…Calibration
is successfully done”.
<
<
PROGRAM
Batch 1 Left
>
>
Turn unit “ON”
“HOME" Screen on left will
appear
Å
EXIT
Immediately place finger on
screen and “HOLD”
Screen on right will appear
<<
T
Æ
(FETCO “HOME” screen)
>>
ÅTop line is programming
category
Å Second line displays
items for programming
Right and left hand arrows
will scroll to the screens that
display “Program, General,
Inputs, Outputs and Other”.
Down arrow enters the
individual programming items
shown below
Programming-category screens: Menu Tree
Programming category screens
To enter: Turn unit “OFF”, After 10 second delay, turn unit “ON”, (Home Screen will appear),
Immediately place finger on screen and “HOLD” PROGRAM Screen (first below) will appear.
Use right/left and down arrows to travel through programming. “EXIT” saves settings
Programming Category
PROGRAM
Items for Programming
Batch 1 LEFT*
Batch 2 Left**
Batch 3 Left **
Batch 4 Left **
Batch 1 RIGHT*
Batch 2 Right **
Batch 3 Right **
Batch 4 Right **
Programming Category
GENERAL
Programming Category
Programming Category
Programming Category
INPUTS
OUTPUTS
OTHER
Items for Programming
Items for Programming
Items for
Programming
Items for Programming
Tank Temp
Brew At Temp
Unit of Meas.
Volume
ECO Mode
Logo Timeout
Brew B.Sensor
Display Inputs
Calib Touch Scr
Left Pump
L.Bypass Pump*
Right Pump
R.Bypass Pump*
Fill Valve
Heater
Screen
*Bypass option is only on
Batch Copy
1 gallon airpot version
12
Error Codes
Display Errors
Reset Errors
Copy Program
From SD to B
From B to SD
Upload Logo
Res to Factory
Firmware
Menu Features: Batch Parameters
Programming Items
Factory set Default
Batch 1 LEFT* • Batch Summary
PROGRAM
Display Summary
• Batch Name
Regular 1(-16)
• Batch Volume
3.05 liter
[ 1.0-4.7]
• Brew Time
• Spray Pattern
Notes
Choose from list:
Regular1
3.03 liter
|_________[]________|
(Regular 1-16)
-OR- Write: any name
0.94
4.73
4:00 mm:ss
|_____[]___________|
4:00 mm:ss
2:00
10:00
Wide
|__[]______________|
Wide
Wide
Middle
Narrow
8
8
|_____[]___________|
0%
0%
|_[]_______________|
0:00 mm:ss
1:30 mm:ss
|[]________________|
• Bypass Perc.
0%
0%
|_[]_______________|
• Drip Delay
1:30 mm:ss
1:30 mm:ss
|_____[]___________|
• Nr Of Pulses
• Prewet Perc.
• Prewet Delay
Batch 2 Left**
Programming Range
1
30
0
15
0:00
1:00
0
40
0:30
Bypass option is only on 1
gallon airpot version
5:00
**Batch 2-4—Right and Batch2-4—Left may be individually selected-or-entirely deleted
ON
|_________[]________|
• Batch ON/OFF
ON
• Batch Summary
• Batch Name
Display Summary
Regular 1-16;Write own name
Regular 1
ON
3.03 liter
|___[]______________|
[ 0.94-4.73]
ON
OFF
• Batch Volume
• Brew Time
• Spray Pattern
• Nr Of Pulses
• Prewet Perc.
0.94
4.73
4:00 mm:ss
|_____[]___________|
4:00 mm:ss
2:00
10:00
Wide
|__[]______________|
Wide
Wide
Middle
Narrow
8
8
|_____[]___________|
0%
0%
|_[]_______________|
• Prewet Delay
0:00 mm:ss
• Bypass Perc.
0%
• Drip Delay
1:30 mm:ss
Batch 3 Left **
Batch 4 Left **
Batch 1 Right *
Batch 2 Right **
Batch 3 Right **
Batch 4 Right **
(See Batch 2-Left)
(See Batch 2-Left)
(See Batch 1-Left)
(See Batch 2-Left)
(See Batch 2-Left)
(See Batch 2-Left)
Batch Copy
Copy From Batch
Copy To Batch
L1
L1
Copy?
L1ÆL2?
(example)
1
10
0
15
0:00 mm:ss
|[]________________|
0:00
1:00
0%
|_[]_______________|
0
40
Bypass option is only on 1
gallon airpot version
1:30 mm:ss
|_____[]_________|
5:00
0:30
L1-L4;R1-R4
L1-L4;R1-R4
NO
|_______________[]__|
YES
NO
*Batch 1&4 cannot be disabled. (CBS-2132); *Batch 1 cannot be disabled. (CBS-2131)
13
**Batch can be disabled, and removed from display
GENERAL
Programming
Items
Factory set
Default
Brew at Temp.
“OFF” allows
brewing at any
temperature.
AUTO
Units of Meas.
• Temperature
°F
• Volume
Liters
Logo Timeout
1:00 mm:ss
Brew B. Sensor
NORMAL
INPUTS
Display Inputs
Programming
Items
Factory set
Default
• Input
Summery
0
500
200
211.1
1000
200
210.2
2000
200
208.4
2500
200
207.5
3000
200
206.6
3500
197
205.7
4000
195
204.8
4500
194
203.9
5000
194
203.0
5500
193
202.0
6000
192
201.1
6500
191
200.2
7000
190
199.3
7500
188
198.3
8000
187
197.4
SEE NOTE BELOW!
Programming Range
(display)
Brew Basket Sensor
†
High Liquid Level probe
„
High Tank Temperature Probe
„
Notes
SD Card Recognized
†
USB Drive Recognized
†
________________[]____
YES
NO
USB is for factory
setup only
If Yes:
Follow directions on
the touch screen
BREW AT TEMPERATURE DEFINITONS
Chart to correct for boiling point for altitude
in tank water temperature.
Boiling
point (° F)
Correction for high
altitude below
Calibrate
Calibrate
Suggested
Setting(°F)
200
Notes
Lower Tank Temperature Probe „
Cal. Touch Scr
Altitude (ft.)
200 °F
|______________[]___|
180
207
AUTO
|____________[]___|
OFF
ON AUTO
°F
|___[]____________|
°F
°C
Liters
|_____________[]__|
Gallons
Liters
1:00 mm:ss
|_[]_______________|
0:00
5:00
NORMAL
|__[]____________|
NORMAL OVERRIDE
200°F
Tank Temp.
Programming Range
(display)
BREW AT TEMP: AUTO
(DEFAULT: FACTORY PROGRAMMED INTO BREWER)
This allows the “BREW START” to active. If the hot water
tank is at the selected temperature—the brew will start.
If the temperature is too low, the brewer will wait until the
proper temperature is reached. A screen (example to the
right) will display showing a thermometer icon and the tank
temperature.
IMPORTANT: ALWAYS have dispenser(s) under the brew
baskets when in the BREW AT TEMP mode.
212.0
BREW AT TEMP: ON
USER SELECTABLE
“BREW START” Batch Section Buttons will not be
accessible until tank temperature is at set point.
The “BREW START” screens with the Batch Section
Buttons become accessible when hot water tank is at the
selected temperature. The screen at right displays when
the “BREW AT TEMP” is selected.
BREW AT TEMP: OFF
USER SELECTABLE
Allows brewing at any temperature above 179°F/82°C. (Not recommended)
.
14
OTHER
Error Codes
Copy
Program
Programming
Items
Factory set
Default
• Display Errors
(Codes)
• Reset Errors
(Reset)
Programming Range
(display)
1:
2:
3:
Reset
!!Errors must be
corrected and cleared!!
Setup upload
SDÆ Brewer
SDÆ Brewer
|________________[]____
YES
NO
• From B to SD
BrewerÆ SD
|________________[]____|
YES
NO
---------------------------------------------------------------------------
Please insert SD card with
the setup data!
Setup download
BrewerÆ SD
---------------------------------------------------------------------------
Please insert SD card with
sufficient space (≥2GB)
UPLOAD LOGO
Are you sure
Upload Logo
Res to
Factory
Chart is below
|_______________[]____|
YES
NO
• From SD to B.
Upload Logo
Notes
Please insert SD
card with logo file!
|________________[]____|
YES
NO
Reset to Default
Are you sure
Reset to default
Completely
overwrites all user
setup, incl. user logo.
|________________[]____|
YES
NO
All Counters
Counters
• Display
Counters
-OR• Reset
Counters
Left Brews
Left Brew activated
Left Brew [liters]
Left Bypass Activated
Left Bypass [liters]
Right Brews
Right Brew activated
Right Brew [liters]
Right Bypass Activated
Right Bypass [liters]
Fill valve Activated
Fill Valve [liters]
Heater Activated
Heater “on” time
Counters
Display Total
Counters
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Resetting will
restart counter
from zero
Touch To Return
• Reset
Counters
Reset All Counters
Are you sure
Reset All
Counters
|________________[]____|
YES
NO
• Firmware
Firmware
Version
-Software type
• Update
Firmware
Firmware Version
SW ver. 1.0.2A
HW ver
BL ver.1.0.1
QP ver. 4.5.01
UPDATE
UPDATE
|________________[]____|
YES
NO
ERROR CODES
Error code 50: Shorted temperature probe
Error code 51: Open temperature probe
Error code 100: Initial Fill Error. Initial fill time was more than 4 minutes after power up.
Error code 101: Error on refill
Error code 102: Unwanted fill; possible leak
Error code 103: Liquid level probe fault
Error code 201: Heater open, high limit thermostat, or Solid State Relay (SSR) fault
15
Displays firmware
version
Firmware upload
---------------------------------------------------------------------------
Please insert SD card with
the firmware file!
OUTPUTS
Programming
Items
Left Pump
• Left Pump Test
’’ ’’
• L. Pump Calib
’’ ’’
L.Bypass Pump*
• Left BP Pump
Test
’’ ’’
• L. BP Pump
Calib
’’ ’’
TEST
Press To Test
(Press to test)
0.49
Calibrate
*Flow Rate
|_________[]________|
0.39
0.59
TEST
Press To Test
0.49
Calibrate
*Flow Rate
• Right Pump Test
’’ ’’
• R. Pump Calib
R.Bypass Pump*
• Right BP Pump
Test
’’ ’’
• R. BP Pump
Calib
’’ ’’
Programming Range
(display)
(Press to test)
Right Pump
’’ ’’
Factory set
Default
|_________[]________|
0.39
0.59
TEST
Press To Test
(Press to test)
0.49
Calibrate
*Flow Rate
|_________[]________|
0.39
0.59
TEST
Press To Test
(Press to test)
0.49
Calibrate
*Flow Rate
|_________[]________|
0.39
0.59
Fill Valve
• Fill Valve Test
(Press to test)
TEST
Press To Test
Heater
• Heater Test
(Press to test)
TEST
Press To Test
Screen
• Screen Contrast
Contrast
|____________[]____|
1
10
• S. Brightness
Brightness
|____________[]____|
1
10
8
8
*Bypass option is only on 1 gallon airpot version
*How to calculate flow rate
Measured Æ
2.90
——— =
Set Point Æ 3.00
If flow rate setting is 0.49
Then new flow rate is
0.49 X 0.96=0.47
0.96
By entering the new flow rate number
into the brewer, the software will
correct the discrepancy in the pump.
16
Notes
Runs pump to verify
flow. Have container
under brewbasket!
Factory or service use
for flow rate
Runs pump to verify
flow. Have container
under brewbasket!
Factory or service use
for flow rate
Runs pump to verify
flow. Have container
under brewbasket!
Factory or service use
for flow rate
Runs pump to verify
flow. Have container
under brewbasket!
Factory or service use
for flow rate
Operates fill valve.
Have container under
both brewbaskets!
Energizes Heater(s)
Use for servicing.
Hot water convenience tap
1. The CBS-2130 coffee brewers include a hot water convenience tap for single cup beverage purposes.
2. Single use delivery volume should not exceed maximum 16fl.oz/473cc.
3. Water dispensed from this faucet is very hot, up to 205°F/96°C
Adjustable spray pattern
This FETCO equipment features digitally adjustable spray patterns for perfect penetration
FETCO CBS-2131 and CBS-2132 coffee brewers feature digitally adjustable spray patterns for perfect penetration.
All batches can be set for wide, middle or narrow spray patterns of the hot brew water that showers the coffee bed
in the brewbasket. The turbulence created by the spray pattern combined with variable pulses is infinitely
adjustable for desired flavor extraction of individual roasts and grinds of any coffee variety.
The default setting for all batches is WIDE. The brewer software calculates and corrects to achieve proper volume
based on the flow rate changes of the spray pattern.
Error Codes
Code
Description
Possible Cause
Corrective Action
050
Shorted temperature probe
Replace probe.
051
Open temperature probe.
Probe failure.
Bad probe
connection, or
probe failure.
100
Initial Fill Error. Initial fill
time was more than 4
minutes after power up.
Water supply flow
rate is too low.
101
Error on refill
Tank did not refill within 3
minutes.
Water supply flow
rate is too low.
102
Unwanted fill;
Possible leak in
tank, fitting, or
valve.
Check inside of machine for
leaks.
103
Liquid level probe fault
Probe fouled or
shorts
Clean, check all
connections. Replace probe
if necessary.
201
Heater open, high limit
thermostat, or Solid State
Relay (SSR) fault
SSR, High Limit,
or heating
element failure.
Check and replace heating
elements if necessary.
Check all connections.
Replace probe if necessary.
Watch for short potting
during brew cycle.
Investigate cause of low flow
rate. (Clogged water filter...)
Watch for short potting
during brew cycle.
Investigate cause of low flow
rate. (Clogged water filter…)
How to Clear
Error Codes
CLEAR FAULT, make
repairs as required
Below is the only way to
clear error codes
1) Enter
“PROGRAMMING”
2)Scroll left to “OTHER”
3)Scroll down to
“ERROR CODES”
4)Scroll down to “Display
Errors”
5)Scroll left to “Reset
Errors”
6)Scroll down to “Reset”
7)Follow directions
shown on screen.
INSERT
Brewbasket must
be in place
Insert brewbasket
Toggling ON/OFF switch
will not clear error codes.
Error codes must be
cleared!
BREW
BASKET
Designs, materials, specifications, physical dimensions, firmware and software protocol for equipment or replacement parts are subject to review and change by FETCO without notice
17
Airpot use instructions and cleaning
Dispenser Diagram
®
D041 (3 liter) and
D063 (1 gallon) Airpot
DESCRIPTION : Dispenser Diagram
The FETCO D041 (3 liter) and D063 (1 gallon) airpots are lever type, air pressure evacuated
beverage dispenser featuring double-wall, vacuum insulated construction.
The hermetically sealed vacuum double-wall construction provides excellent heat or cold
retention, while the stainless steel outer and inner liners provide robust durability.
PARTS :
Locking Tab
Lever
Bellow Cap
Bellow
Bellow Cap Plate
Spout Tube
Drip-Through
Down Tube
Lip Release Button
18
Dispenser Operation Instructions
®
D041 (3 liter) and
D063 (1 gallon) Airpot
To Fill :
brewer to dispense the
1 Set
proper amount into the
2
airpot :
3 liters (FETCO D041)
-or1gallon (FETCO D063)
Squeeze the Lid Release
Buttons to release the lid.
3
Place the airpot under the
brewer against the airpot
dispenser Locator (if
featured).
Align the center of the
airpot Drip-Through with
the outlet of the
brewbasket.
3
Push the lever downwards
multiple times to dispense
the desired amount
Swing the lid completely
backwards
To Dispense:
the brew cycle is
1 After
completed:
Remove the airpot from
under the brewbasket and
close the lid.
2
Lift the handle up until the
Lever Lock drops into
position, and engages the
pump mechanism.
19
Dispenser Cleaning & Maintenance
®
D041 (3 liter) and
D063 (1 gallon) Airpot
To Clean :
the Lid Release
1 Squeeze
Buttons to release the lid.
2
Press the Lid Detach Button
that will completely detach
the lid.
Remove the Lid Cover.
Remove the Drip-Through
Detach the Down-Tube
and the Spout-Tube.
Clean with warm water,
detergent and a brush.
Proprietary airpot cleaners
may also be used.
3
Carefully remove the
bellows Cap.
Handling the parts gently,
clean the Bellows,
Bellows Cap, and Bellow
Cap Plate with warm
water, and non-abrasive
mild detergent.
C4H9OCH2CH2OH
the interior of the tank 5
4 Clean
with warm water, detergent
and a brush. Proprietary
airpot cleaners may also be
used.
Do not put the airpot into
an automatic dishwasher.
Do not allow solutions
containing chlorine to
remain in tank.
Clean the exterior of the
unit with warm water, nonabrasive mild detergent.
Do not submerge the unit
in water
20
6
Do not use petroleum
based or organic cleaners
on food equipment.
Never use cleaners or
polishes formulated with
the solvent diethylene
glycol butyl ether(DGBE)
on any equipment.
FETCO CBS-2130
®
COFFEE BREWING SYSTEM
Complete Commercial Parts Listing
For CBS-2131 and CBS-2132 Model Range
Includes types for the 3 liter and 1 gallon airpot dispensers
NEW September, 2012
Please see our website-www.fetco.com for the most up to date listings and additional parts and service information
Designs, materials, specifications, physical dimensions, firmware and software protocol for equipment or replacement parts are subject to change without notice.
21
Parts diagrams, bill of materials lists
22
Drawing 1101.00128.00
CBS-2131ASSEMBLY, 1gallon NO BYPASS, 2.3kW/120VAC
Ref#
Qty Part number
Description
1
1
1111.00030.00
WELDMENT BODY, CBS-2131
2
2
1024.00049.00
EDGE PROTECTOR, 7.00"LG, CBS-2130
3
3
1086.00004.00
BUSHING, SNAP, 1" MOUNTING HOLE
4
1
1024.00017.00
O'RING, 3.739" ID X 0.070" CS, 70 DURO, BUNA "N", FDA
5
1
1102.00183.00
SPRAY HOUSING ASSEMBLY, CBS-2130
6
4
1083.00010.00
WASHER, #10 SCREW W/NEOPRENE-BONDED SEAL
7
8
1084.00006.00
NUT, 8-32 18-8 HEX MACHINE SCREW
8
1
1102.00113.00
SWITCH, REED, ASSEMBLY
9
4
1029.00006.00
#4-40 NYLON FINGER NUT
10
1
1071.00010.00
FAUCET HPSC-BR-8 REGULAR HANDLE
11
1
1031.00003.00
FITTING, BARB 3/8'ID x 1/4" FPT
12
1
1057.00043.00
SOLENOID VALVE, SINGLE, 180 DEG, 24VDC
13
1
14
2
1083.00005.00
WASHER, M4 18-8 INTERNAL TOOTH LOCKWASHER
15
2
1082.00010.00
SCREW, M4x10 ZINC PLATED PAN PHILLIPS MACHINE
16
1
1102.00164.00
ADAPTER ASSY, 3/4" BSP X 1/4 SAE FLARE
17
1
1104.00043.00
TANK ASSY, 2300W/120VAC, CBS-2131, GROMMETS
18
1
1112.00163.00
WELDMENT TANK LOCK BRACKET, CBS-2100
19
4
1083.00011.00
WASHER, #8 SCREW SIZE, INTERNAL TOOTH LOCK
20
2
1082.00023.00
SCREW, #8-32 X 3/8 TRUSS HD PHIL., MACHINE
21
1
1102.00187.00
PUMP BRACKET AND HOLDER ASSEMBLY
22
9
1086.00003.00
UNICLAMP, 15.9 HOSE OD CLAMP
23
1
1025.00063.00
TUBE, 5/8'OD X 3/8"ID X 8.50"LG
24
1
1102.00181.00
ASSEMBLY BACK PANEL, CBS-2130
25
11
1082.00017.00
SCREW, # 6-32 X 1/2" TRUSS HD PHIL., MACHINE
26
1
1023.00147.00
PLUG, TANK SERVICE DRAIN FOR 18GA AND UP BODY
27
1
1024.00040.00
CARD PLUG, HWD-2100
28
1
1102.00190.00
ASSEMBLY FRONT PANEL, CBS-2100
29
4
1082.00058.00
SCREW, # 8-32 X 5/8, FLAT HD, PH, 18-8 SS
30
1
1102.00182.00
ASSEMBLY, LOCATOR CBS-2130
31
1
1082.00065.00
SCREW #8-32 X 1 1/2", FLAT HD PH, 18-8 SS
32
1
1023.00159.00
CORNER INSERT
33
1
1112.00168.00
WELDMENT, TOP COVER, CBS-2131
34
1
1402.00034.00
HARNESS, HIGH AMP, CBS-2131
35
1
1402.00035.00
HARNESS, LOW AMP, CBS-2131
36
1
B012280B1
BB ASSY, 13"X5", .280" DIA. HOLE, BLK HNDL
37
1
1024.00052.00
CONNECTOR, BREW PUMP
38
1
1086.00002.00
CLAMP, HOSE, SIZE "G" NYLON
39
1
1055.00001.00
PUMP, HOT LIQUID
40
1
1025.00012.00
TUBE, 5/16'OD X 3/16"ID X 11.00"LG
41
1
1025.00061.00
TUBE, 9/16'OD X 5/16"ID X 2.75"LG
42
1
1029.00002.00
FITTING, HOSE BARB TEE, SIZE 3/8" , NYLON
43
1
1025.00058.00
TUBE, 9/16'OD X 5/16"ID X 25.00"LG
44
1
1025.00060.00
TUBE, 9/16'OD X 5/16"ID X 3.25"LG
45
1
1083.00009.00
WASHER, #6 SCREW , INTL TOOTH LOCKWASHER
46
1
1084.00010.00
NUT, HEX, #6-32, UNDERSIZED, ZINC PLATED
47
1
1025.00006.00
TUBE, VENT SUPPORT, 5/16" OD X 3/16" ID X 1/2" LG
48
1
1025.00064.00
TUBE, 1/2 OD X 1/4 ID X 9.00 LG
49
1
1013.00073.00
TUBE, 5/16" OD, 1" LONG
50
1
1046.00006.00
LABEL, WARNING, "HOT WATER FAUCET"
51
1
1044.00004.00
LABEL, DANGER, HIGH VOLTAGE
52
1
1046.00003.00
LABEL, CSD WARNING, 1.5" X 5.0"
53
4
1023.00163.00
LEG BODY, CBS-2130
54
4
1083.00021.00
WASHER, 1/4" SCREW SIZE, SPRING LOCK
55
4
1112.00158.00
WELDMENT, LEG ROD, CBS-2130
56
4
1021.00017.00
LEG INSERT THREADED, CBS-2130
23
24
Ref#
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
Drawing 1101.00127.00
QTY
PART NO
1
1111.00030.00
2
1024.00049.00
3
1086.00004.00
1
1024.00017.00
1
1102.00183.00
4
1083.00010.00
8
1084.00006.00
1
1102.00113.00
4
1029.00006.00
1
1071.00010.00
1
1031.00003.00
1
1057.00043.00
1
2
1083.00005.00
2
1082.00010.00
1
1102.00164.00
1
1104.00043.00
1
1112.00163.00
4
1083.00011.00
2
1082.00023.00
1
1102.00187.00
9
1086.00003.00
1
1025.00063.00
1
1102.00181.00
11
1082.00017.00
1
1023.00147.00
1
1024.00040.00
1
1102.00190.00
4
1082.00058.00
1
1102.00182.00
1
1082.00065.00
1
1023.00159.00
1
1112.00168.00
1
1402.00034.00
1
1402.00035.00
1
B012280B1
4
1073.00008.00
4
1082.00066.00
1
1024.00052.00
1
1086.00002.00
1
1055.00001.00
1
1025.00012.00
1
1025.00061.00
1
1029.00002.00
1
1025.00058.00
1
1025.00060.00
1
1083.00009.00
1
1084.00010.00
1
1025.00006.00
1
1025.00064.00
1
1013.00073.00
1
1046.00006.00
1
1044.00004.00
1
1046.00003.00
CBS-2131ASSEMBLY, 3 Liter NO BYPASS , 2.3kW/120VAC
DESCRIPTION
WELDMENT BODY, CBS-2131
EDGE PROTECTOR, 7.00"LG, CBS-2130
BUSHING, SNAP, 1" MOUNTING HOLE
O'RING, 3.739" ID X 0.070" CS, 70 DURO, BUNA
SPRAY HOUSING ASSEMBLY, CBS-2130
WASHER, #8 SCREW SIZE W/NEOPRENE- BONDED SEAL
NUT, 8-32 18-8 HEX MACHINE SCREW
SWITCH, REED, ASSEMBLY
#4-40 NYLON FINGER NUT
FAUCET HPSC-BR-8 REGULAR HANDLE
FITTING, BARB 3/8'ID x 1/4" FPT
SOLENOID VALVE, SINGLE, 180 DEG, 24VDC
WASHER, M4 18-8 INTERNAL TOOTH LOCKWASHER
SCREW, M4x10 ZINC PLATED PAN PHILLIPS MACHINE
ADAPTER ASSY, 3/4" BSP X 1/4 SAE FLARE
TANK ASSY, 2300W/120VAC, CBS-2131, GROMMETS
WELDMENT TANK LOCK BRACKET, CBS-2100
WASHER, #8 SCREW SIZE, INTERNAL TOOTH LOCK
SCREW, #8-32 X 3/8 TRUSS HD PHIL., MACHINE
PUMP BRACKET AND HOLDER ASSEMBLY
UNICLAMP, 15.9 HOSE OD CLAMP
TUBE, 5/8'OD X 3/8"ID X 8.50"LG
ASSEMBLY BACK PANEL, CBS-2130
SCREW, # 6-32 X 1/2" TRUSS HD PHIL., MACHINE
PLUG, TANK SERVICE DRAIN FOR 18GA AND UP BODY
CARD PLUG, HWD-2100
ASSEMBLY FRONT PANEL, CBS-2100
SCREW, # 8-32 X 5/8, FLAT HD, PH, 18-8 SS
ASSEMBLY, LOCATOR CBS-2130
SCREW #8-32 X 1 1/2", FLAT HD PH, 18-8 SS
CORNER INSERT
WELDMENT, TOP COVER, CBS-2131
HARNESS, HIGH AMP, CBS-2131
HARNESS, LOW AMP, CBS-2131
BB ASSY, 13"X5", .280" DIA. HOLE, BLK HNDL
FOOT, CBS-2130
SCREW 1/4-20 X 1/2", SOCKED HD CUP
CONNECTOR, BREW PUMP
CLAMP, HOSE, SIZE "G" NYLON
PUMP, HOT LIQUID
TUBE, 5/16'OD X 3/16"ID X 11.00"LG
TUBE, 9/16'OD X 5/16"ID X 2.75"LG
FITTING, HOSE BARB TEE, SIZE 3/8" , NYLON
TUBE, 9/16'OD X 5/16"ID X 25.00"LG
TUBE, 9/16'OD X 5/16"ID X 3.25"LG
WASHER, #6 SCREW , INTL TOOTH LOCKWASHER
NUT, HEX, #6-32, UNDERSIZED, ZINC PLATED
TUBE, VENT SUPPORT, 5/16" OD X 3/16" ID X 1/
TUBE, 1/2 OD X 1/4 ID X 9.00 LG
TUBE, 5/16" OD, 1" LONG
LABEL, WARNING, "HOT WATER FAUCET"
LABEL, DANGER, HIGH VOLTAGE
LABEL, CSD WARNING, 1.5" X 5.0"
25
Drawing 1104.00043.00 TANK ASSY, 2300W/120VAC, CBS-2131, GROMMETS
Ref#
1
2
3
4
5
6
7
8
9
10
11
12
12
12
12
12
13
14
15
16
17
18
19
20
QTY
1
4
1
2
1
1
2
2
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
PART NO
1114.00066.00
1024.00050.00
1024.00051.00
1024.00053.00
1003.00005.00
1053.00003.00
1083.00009.00
1084.00010.00
1003.00140.00
1052.00014.00
1081.00042.00
1107.00021.00
1107.00022.00
1107.00019.00
1107.00020.00
1107.00018.00
1112.00002.00
1102.00161.00
1024.00007.00
1102.00007.00
1023.00167.00
1023.00168.00
1023.00166.00
1022.00056.00
DESCRIPTION
WELDMENT TANK CBS-2131, GROMMET DESIGN
GROMMET, SILICONE, 11.4mm ID
GROMMET, SILICONE, BLANK
GROMMET, SILICONE, LL & TEMP. PROBES
BRACKET, ONE SHOT THERMOSTAT
THERMOSTAT, SINGLE SHOT, 240V/40A
WASHER, #6 SCREW , INTL TOOTH LOCKWASHER
NUT, HEX, #6-32, UNDERSIZED, ZINC PLATED
ALUMINUM BRACKET FOR SSR
ASSEMBLY RELAY, SOLID STATE, 25A/230V
STANDOFF, 6-32 x1.25 LG.,1/4 HEX WIDTH
HEATER ASSEMBLY, IMMERSION 1500W/120VAC
HEATER ASSEMBLY, IMMERSION 1700W/120VAC
HEATER ASSEMBLY, IMMERSION 2300W/120VAC
HEATER ASSEMBLY, IMMERSION 2300W/240VAC
HEATER ASSEMBLY, IMMERSION 3000W/240VAC
PROBE WELDMENT, WATER LEVEL 2.25" LG
PROBE ASSEMBLY, TEMP. AND LLC, HWD-2100
O-RING, DASH #344, TANK COVER
TANK COVER ASSEMBLY
FITTING, BREW, GROMMET DESIGN
FITTING, HOT WATER, GROMMET DESIGN
FITTING, COLD WATER INLET, GROMMET DESIGN
TANK INSULATION, CBS-2131e, GROMMET DESIGN
26
27
Drawing 1101.00132.00
Ref#
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
QTY
1
2
6
2
2
8
12
2
6
1
1
1
1
2
2
1
1
1
4
2
1
2
2
10
2
1
1
1
1
1
1
11
1
1
1
4
2
2
2
1
1
1
2
2
1
1
2
2
2
3
3
CBS-2132-3 Liter NO BYPASS
PART NO
DESCRIPTION
1111.00029.00
1024.00049.00
1086.00004.00
1024.00017.00
1102.00183.00
1083.00010.00
1084.00006.00
1102.00113.00
1029.00006.00
1071.00010.00
1031.00003.00
1057.00043.00
WELDMENT BODY, CBS-2132
EDGE PROTECTOR, 7.00"LG, CBS-2130
BUSHING, SNAP, 1" MOUNTING HOLE
O'RING, 3.739" ID X 0.070" CS, 70 DURO, BUNA
SPRAY HOUSING ASSEMBLY, CBS-2130
WASHER, #8 SCREW SIZE W/NEOPRENE- BONDED SEAL
NUT, 8-32 18-8 HEX MACHINE SCREW
SWITCH, REED, ASSEMBLY
#4-40 NYLON FINGER NUT
FAUCET HPSC-BR-8 REGULAR HANDLE
FITTING, BARB 3/8'ID x 1/4" FPT
SOLENOID VALVE, SINGLE, 180 DEG, 24VDC
1083.00005.00
1082.00010.00
1102.00164.00
1104.00044.00
1112.00163.00
1083.00011.00
1082.00023.00
1102.00187.00
1024.00052.00
1055.00001.00
1086.00003.00
1025.00012.00
1029.00002.00
1025.00060.00
1025.00061.00
1025.00058.00
1025.00063.00
1102.00181.00
1082.00017.00
1023.00147.00
1024.00040.00
1102.00190.00
1082.00058.00
1102.00182.00
1082.00065.00
1023.00159.00
1112.00167.00
1402.00032.00
1402.00033.00
B012280B1
1086.00002.00
1083.00009.00
1084.00010.00
1025.00006.00
1025.00064.00
1013.00073.00
1073.00008.00
1082.00066.00
WASHER, M4 18-8 INTERNAL TOOTH LOCKWASHER
SCREW, M4x10 ZINC PLATED PAN PHILLIPS MACHINE
ADAPTER ASSY, 3/4" BSP X 1/4 SAE FLARE
TANK ASSY, 2 X 3000W/240VAC, CBS-2132, GROMMETS
WELDMENT TANK LOCK BRACKET, CBS-2100
WASHER, #8 SCREW SIZE, INTERNAL TOOTH LOCK
SCREW, #8-32 X 3/8 TRUSS HD PHIL., MACHINE
PUMP BRACKET AND HOLDER ASSEMBLY
CONNECTOR, BREW PUMP
PUMP, HOT LIQUID
UNICLAMP, 15.9 HOSE OD CLAMP
TUBE, 5/16'OD X 3/16"ID X 11.00"LG
FITTING, HOSE BARB TEE, SIZE 3/8" , NYLON
TUBE, 9/16'OD X 5/16"ID X 3.25"LG
TUBE, 9/16'OD X 5/16"ID X 2.75"LG
TUBE, 9/16'OD X 5/16"ID X 25.00"LG
TUBE, 5/8'OD X 3/8"ID X 8.50"LG
ASSEMBLY BACK PANEL, CBS-2130
SCREW, # 6-32 X 1/2" TRUSS HD PHIL., MACHINE
PLUG, TANK SERVICE DRAIN FOR 18GA AND UP BODY
CARD PLUG, HWD-2100
ASSEMBLY FRONT PANEL, CBS-2100
SCREW, # 8-32 X 5/8, FLAT HD, PH, 18-8 SS
ASSEMBLY, LOCATOR CBS-2130
SCREW #8-32 X 1 1/2", FLAT HD PH, 18-8 SS
CORNER INSERT
WELDMENT, TOP COVER, CBS-2132
HARNESS, HIGH AMP, CBS-2132
HARNESS, LOW AMP, CBS-2132
BB ASSY, 13"X5", .280" DIA. HOLE, BLK HNDL
CLAMP, HOSE, SIZE "G" NYLON
WASHER, #6 SCREW , INTL TOOTH LOCKWASHER
NUT, HEX, #6-32, UNDERSIZED, ZINC PLATED
TUBE, VENT SUPPORT, 5/16" OD X 3/16" ID X 1/
TUBE, 1/2 OD X 1/4 ID X 9.00 LG
TUBE, 5/16" OD, 1" LONG
FOOT, CBS-2130
SCREW 1/4-20 X 1/2", SOCKED HD CUP
28
2 X 3kW/240VAC
29
1101.00131.00 CBS-2132, 2 X 3kW/240VAC, 1gal BYPASS
Ref#
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
Qty
1
2
6
2
2
8
12
2
6
1
1
1
1
2
2
1
1
1
4
2
1
2
4
12
4
1
1
1
1
1
1
11
1
1
1
4
2
2
2
1
3
3
3
3
1
1
2
2
1
1
2
2
2
1111.00029.00
1024.00049.00
1086.00004.00
1024.00017.00
1102.00183.00
1083.00010.00
1084.00006.00
1102.00113.00
1029.00006.00
1071.00010.00
1031.00003.00
1057.00043.00
WELDMENT BODY, CBS-2132
EDGE PROTECTOR, 7.00"LG, CBS-2130
BUSHING, SNAP, 1" MOUNTING HOLE
O'RING, 3.739" ID X 0.070" CS, 70 DURO, BUNA
SPRAY HOUSING ASSEMBLY, CBS-2130
WASHER, #10 SCREW W/NEOPRENE-BONDED SEAL
NUT, 8-32 18-8 HEX MACHINE SCREW
SWITCH, REED, ASSEMBLY
#4-40 NYLON FINGER NUT
FAUCET HPSC-BR-8 REGULAR HANDLE
FITTING, BARB 3/8'ID x 1/4" FPT
SOLENOID VALVE, SINGLE, 180 DEG, 24VDC
1083.00005.00
1082.00010.00
1102.00164.00
1104.00044.00
1112.00163.00
1083.00011.00
1082.00023.00
1102.00187.00
1024.00048.00
1055.00001.00
1086.00003.00
1025.00012.00
1029.00002.00
1025.00060.00
1025.00061.00
1025.00058.00
1025.00063.00
1102.00181.00
1082.00017.00
1023.00147.00
1024.00040.00
1102.00190.00
1082.00058.00
1102.00182.00
1082.00065.00
1023.00159.00
1112.00167.00
1023.00163.00
1083.00021.00
1112.00158.00
1021.00017.00
1402.00032.00
1402.00033.00
B012280B1
1086.00002.00
1083.00009.00
1084.00010.00
1025.00006.00
1025.00064.00
1013.00073.00
WASHER, M4 18-8 INTERNAL TOOTH LOCKWASHER
SCREW, M4x10 ZINC PLATED PAN PHILLIPS MACHINE
ADAPTER ASSY, 3/4" BSP X 1/4 SAE FLARE
TANK ASSY, 2 X 3000W/240VAC, CBS-2132, GROMMETS
WELDMENT TANK LOCK BRACKET, CBS-2100
WASHER, #8 SCREW SIZE, INTERNAL TOOTH LOCK
SCREW, #8-32 X 3/8 TRUSS HD PHIL., MACHINE
PUMP BRACKET AND HOLDER ASSEMBLY
Y-CONNECTOR
PUMP, HOT LIQUID
UNICLAMP, 15.9 HOSE OD CLAMP
TUBE, 5/16'OD X 3/16"ID X 11.00"LG
FITTING, HOSE BARB TEE, SIZE 3/8" , NYLON
TUBE, 9/16'OD X 5/16"ID X 3.25"LG
TUBE, 9/16'OD X 5/16"ID X 2.75"LG
TUBE, 9/16'OD X 5/16"ID X 25.00"LG
TUBE, 5/8'OD X 3/8"ID X 8.50"LG
ASSEMBLY BACK PANEL, CBS-2130
SCREW, # 6-32 X 1/2" TRUSS HD PHIL., MACHINE
PLUG, TANK SERVICE DRAIN FOR 18GA AND UP BODY
CARD PLUG, HWD-2100
ASSEMBLY FRONT PANEL, CBS-2100
SCREW, # 8-32 X 5/8, FLAT HD, PH, 18-8 SS
ASSEMBLY, LOCATOR CBS-2130
SCREW #8-32 X 1 1/2", FLAT HD PH, 18-8 SS
CORNER INSERT
WELDMENT, TOP COVER, CBS-2132
LEG BODY, CBS-2130
WASHER, 1/4" SCREW SIZE, SPRING LOCK
WELDMENT, LEG ROD, CBS-2130
LEG INSERT THREADED, CBS-2130
HARNESS, HIGH AMP, CBS-2132
HARNESS, LOW AMP, CBS-2132
BB ASSY, 13"X5", .280" DIA. HOLE, BLK HNDL
CLAMP, HOSE, SIZE "G" NYLON
WASHER, #6 SCREW , INTL TOOTH LOCKWASHER
NUT, HEX, #6-32, UNDERSIZED, ZINC PLATED
TUBE, VENT SUPPORT, 5/16" OD X 3/16" ID X 1/
TUBE, 1/2 OD X 1/4 ID X 9.00 LG
TUBE, 5/16" OD, 1" LONG
30
REF#
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
QTY
1
2
6
1
2
1
1
2
2
2
2
4
1
1
1
1
2
1
1
1
6
1
TANK ASSY, 2 X 3000W/240VAC, CBS-2132, GROMMETS
PART NO
DESCRIPTION
1114.00062.00
WELDMENT TANK CBS-2132e, GROMMET DESIGN
1024.00053.00
GROMMET, SILICONE, LL & TEMP. PROBES
1024.00050.00
GROMMET, SILICONE, 11.4mm ID
1024.00051.00
GROMMET, SILICONE, BLANK
1107.00018.00
HEATER ASSEMBLY, IMMERSION 3000W/240VAC
1003.00005.00
BRACKET, ONE SHOT THERMOSTAT
1053.00003.00
THERMOSTAT, SINGLE SHOT, 240V/40A
1083.00009.00
WASHER, #6 SCREW , INTL TOOTH LOCKWASHER
1084.00010.00
NUT, HEX, #6-32, UNDERSIZED, ZINC PLATED
1003.00140.00
ALUMINUM BRACKET FOR SSR
1052.00016.00
ASSEMBLY RELAY, SOLID STATE, 50A/600VAC
1081.00042.00
STANDOFF, 6-32 x1.25 LG.,1/4 HEX WIDTH
1112.00002.00
PROBE WELDMENT, WATER LEVEL 2.25" LG
1102.00161.00
PROBE ASSEMBLY, TEMP. AND LLC, HWD-2100
1024.00007.00
O-RING, DASH #344, TANK COVER
1102.00007.00
TANK COVER ASSEMBLY
1023.00167.00
FITTING, BREW, GROMMET DESIGN
1023.00168.00
FITTING, HOT WATER, GROMMET DESIGN
1023.00166.00
FITTING, COLD WATER INLET, GROMMET DESIGN
1022.00057.00
TANK INSULATION, CBS-2132e, GROMMET DESIGN
1065.00006.00
CONNECTOR, TAB, .250", FASTON
1044.00004.00
LABEL, DANGER, HIGH VOLTAGE
31
1102.00183.00 PCSD Pump Spray Housing Assembly
Parts
Ref. QTY PART NO
DESCRIPTION
1
1
1102.00020.00
2
3
1
1
1024.00045.00
1023.00164.00
4
2
1082.00068.00
5
1
1102.00019.00
SPRAY HOUSING ASSY&
MAGNETS, CSD DESIGN
O-RING, 5/8 X 13/16, 3/32
SPRAY HOUSING ADAPTER
SCREW, M3.9x13, CHEESE PH.,
T/FORM
CASCADE SPRAY DOME
ASSEMBLY
Complete CBS-2130 Spray Housing Assembly
-Part number 1102.00183.00
CBS-2100 Series Brew Basket Assembly, 13” X 5”, Part # B012280B1 (SQUARE)
Ref#
1
2
3
4
5
Qty
1
1
1
1
1
Part Number
1112.00073.00
1102.00064.00
1082.00040.00
1009.00006.00
1046.00025.00
Description
BB WLDMNT, 13"X5", W/ Ø.280 HOLE
HANDLE W/MAGNET ASSEMBLY, BLACK RUBBER
SCREW, 1/4-20 X .5, FL HD, PH., W/NYLON
BASKET, WIRE, 13" X 5", CBS-2040'S
LABEL, BREW BASKET WARNING
Never strike or hit a
brewbasket against
any hard surface
32
Download PDF