Repair Parts and Maintenance Guide
Optima® EAF-700
PARTS LIST—EAF-700 FAUCETS
Item
No.
1.
2.
3.
4.
5.
6.
7.
8.
EAF-700
9.
10.
11.
12.
1
12
Code No.
—
—
—
0335001
—
0335000
—
0335024
0335025
0335015
3335023
0335007
0335009
3335086
Part No.
––
––
––
EAF-2
––
EAF-1
EAF-44
EAF-24-A
EAF-25-A
EAF-17-A
EAF-1008
EAF-9
EAF-11-A
EAF-1014-A
3335087
EAF-1015-A
3335088
EAF-1016-A
Description
Spout Assembly
Integral Side Mixer Handle Cap
Integral Side Mixer Kit
Solenoid
Sensor Assembly
Mounting Hardware
Power Splitter
11-13/16” (300 mm) Extension Cable
47-1/4” (1200 mm) Extension Cable
126” (3200 mm) Extension Cable
13” (330 mm) Flexible Supply Hose
Filter/Strainer
Plug-in Voltage Adapter, US Plug
Multi-Lam Spray Head Kit 0.5 gpm (1.9 Lpm)
Male Cache TJ
Spray Head Kit 1.5 gpm (5.7 Lpm) Aerated Male
Cache TJ
Spray Head Kit 1.5 gpm (5.7 Lpm) Laminar Male
Cache TJ
2
3
5
4
Hand Hygiene
6
Electrical Connection for up to Six (6) Faucets
Using One (1) Adapter
9
7
8
10
6 VDC PLUG-IN
ADAPTER
11
POWER
SPLITTER
ELECTRICAL
CABLE
166
POWER
SPLITTER
ELECTRICAL
CABLE
POWER
SPLITTER
ELECTRICAL
CABLE
TO ADDITIONAL
FAUCETS
(6 MAX.)
Repair Parts and Maintenance Guide
Optima® EAF-700
OPERATION
SENSOR RANGE ADJUSTMENT
As the user’s hands enter the beam’s effective range, the beam is reflected
back into the sensor receiver and activates the solenoid valve allowing water
to flow from the faucet. Water will flow until the hands of the user are
removed or until the faucet reaches its automatic time out limit setting.
Factory setting is appropriate for the
majority of applications and should
not require resetting unless under
extreme situations.
8x
7x
SET AND FIX TEMPERATURE (OPTIONAL)
Step 1
1x
Step 3
2x
FACTORY DEFAULT = 6
Step 1
Step 4
Step 2
2x +
1x5 Sec.
Step 5
Step 2
4x
HOT LIMIT STOP ADJUSTMENT
Limit the maximum water temperature. Note: this does not take the place of
an ASSE 1070 certified mixing device. But is an added measure to limit
delivery of hot water.
Step 1
5 Sec.
Step 4
Step 3
1x(
1x, 2x,...,5x)
Hand Hygiene
Step 2
Step 5
Step 3
167
Repair Parts and Maintenance Guide
Optima® EAF-700
12/24 LINE PURGE FEATURE
This feature will operate the faucet
every 12 or 24 hours since last use,
if not used to prevent stagnant
water conditions.
Default purge duration is
two (2) minutes.
Consult factory regarding other
timing options.
OFF-DELAY (FOLLOW UP TIME)
Duration of time the water runs
after target is removed.
Press the button for approximately
six (6) seconds. Release.
1x 24 sec
2x
Press again (water flows) and
release when the desired time of
water flow (0-5 seconds) is
reached.
I.Q.-CLICK FEATURE
1. CONTINUOUS RUN
Continuous run of water for
two minutes.
Faucet will operate normally after
two minutes or after pressing
i.q.-click button once.
Hand Hygiene
2. CLEANING MODE
Pause faucet for cleaning for
two (2) minutes.
Faucet will operate normally after
two (2) minutes or after pressing
i.q.-click button once.
1 x 2 Sec.
Sensor will flash once and then the
faucet is ready to operate.
1x
2x
1x
168
1x
Repair Parts and Maintenance Guide
Optima® EAF-700
TROUBLESHOOTING GUIDE
CARE AND CLEANING
DO NOT USE abrasive or chemical cleaners
(including chlorine bleach) to clean faucets that
may dull the luster and attack the chrome or
special decorative finishes. Use ONLY mild soap
and water, then wipe dry with clean cloth or
towel. While cleaning the bathroom sink, protect
the faucet from any splattering of cleaner. Acids
and cleaning fluids will discolor or remove
chrome plating.
1. Faucet does not function.
A. Adhesive packaging label affixed over sensor eye.
Remove adhesive label from sensor eye.
B. “Intermittent Off” is activated.
Press button once.
C. Water supply stop(s) closed.
Open water supply stop(s).
D. Battery is “dead”.
Replace battery (refer to Battery Replacement section of guide).
2. Faucet delivers water in an uncontrolled manner.
A. Reflection.
Remove reflective surface.
B. Faucet is not working properly.
Contact Sloan Technical Support at
1-888-SLOAN-14 (1-888-756-2614).
When assistance is required, please
contact Sloan Technical Support at:
1-888-SLOAN-14 (1-888-756-2614).
3. Faucet does not deliver any water when Sensor is activated.
INDICATOR: Solenoid Valve produces an audible “CLICK.”
A. Water supply stop(s) closed.
Open water supply stop(s).
B. Water supply stop strainer(s) clogged.
Remove, clean, and reinstall water supply stop strainer(s). Replace
strainer(s), if required.
INDICATOR: Solenoid Valve DOES NOT produce an audible “CLICK.”
A. Power failure.
Check power supply.
Hand Hygiene
4. Faucet delivers only a slow flow or dribble when sensor is
activated.
A. Water supply stop(s) are partially closed.
Completely open water supply stop(s).
B. Water supply stop strainer(s) clogged.
Remove, clean, and reinstall water supply stop strainer(s). Replace
strainer(s), if required.
C. Spray head is clogged.
Remove, clean, and reinstall spray head. Replace spray head,
if required.
D. Faucet is not working properly.
Contact Sloan Technical Support at
1-888-SLOAN-14 (1-888-756-2614).
5. Faucet does not stop delivering water or contrinues to drip after
user is no longer detected.
A. Faucet is not working properly.
Contact Sloan Technical Support at
1-888-SLOAN-14 (1-888-756-2614).
6. The water temperature is too hot or too cold on a faucet
connected to hot and cold supply lines.
A. Supply stops are not adjusted properly.
Adjust supply stops.
169
Download PDF