xcm.LCD Software Installation &

Part # XCM-LCD-C; XCM-LCD-G; 50028399-001
xcm.LCD Software Installation & Update Instructions
Table of Contents
Introduction ......................................................................................1 Software Installation ........................................................................2 Update Device via USB ...................................................................4 Update via Opus Supervisor ..........................................................14 Upgrade Version 1 to Version 2 via USB drive ............................19 Upgrade Version 1 to Version 2 via Opus Supervisor ...................21 Introduction
As part of Novar’s Opus™ Energy Management System, the xcm.LCD
uses Novar’s patent pending EZ-Nav™ technology to provide real-time
status information on an easy-to-use, wall-mounted touch-screen LCD.
The xcm.LCD has a 480 x 272, High Definition, 24-bit Full Color backlit
LCD display. It is also available in a 16-level Extended Temperature
Gray-Scale Display, both have an 8 square inch viewing area.
The xcm.LCD has customizable user screens, multi-language capability,
and permission-based access control. With these features it provides site
personnel the ability to quickly and conveniently access setpoint
changes, local alarm data, and other system information.
This document is the Software Installation & Update Instructions for
software installation, and update of the Novar xcm.LCD. For further
instructions and updated material, go to www.novar.com/manuals to
download the following:



xcm.LCD Mounting & Wiring Instructions
xcm.LCD User Guide
xcm.LCD Advanced Programming Guide
XCM LCD- SW INS 6/16/2011
For the latest technical documentation, visit www.novar.com/manuals
1
Part # XCM-LCD-C; XCM-LCD-G; 50028399-001
Software
Installation
Complete the software installation procedure to install necessary files for
making use of the xcm.LCD display unit within a Novar Opus Energy
Management system.
The following procedure will add files into an existing Novar Opus
Supervisor installation.
Step Table
Step
Procedure
1
Download “xcm.LCD_Support_version#.zip” from the Novar website
(Register or log-in at www.novar.com and select Software
Updates under MyNovar.) and extract and open the executable
file to begin the installation.
2
(If prompted for a password, a Novar representative should be
contacted at 1-800-348-1235)
Select Next on the installation welcome screen after which a required
license agreement will display. The installation will terminate
unless the agreement is accepted.
Figure 1. “xcm.LCD_Support_version#.zip” welcome screen
XCM LCD- SW INS 6/16/2011
For the latest technical documentation, visit www.novar.com/manuals
2
Part # XCM-LCD-C; XCM-LCD-G; 50028399-001
Figure 2. License Agreement
3
4
Once the End User License Agreement is read, click the bullet beside
“I accept the terms of the license agreement” and then select the
Next button to continue the installation. This will prompt
installation via the default target directory of the existing Opus
Supervisor installation.
Select Yes to accept the default location. If No was selected, follow
the prompts to browse and select an alternate directory.
Figure 3. Default directory prompt
Figure 4. File installation progress bar
XCM LCD- SW INS 6/16/2011
For the latest technical documentation, visit www.novar.com/manuals
3
Part # XCM-LCD-C; XCM-LCD-G; 50028399-001
5
If the installation cannot establish the location of the Opus
Supervisor, the following message will be displayed.
Figure 5. Directory not found prompt
6
If the directory is not found, an alternate location may be chosen;
however, this may also mean that the Opus environment is not
setup.
7
Upon completion, the Opus Supervisor is capable of supporting the
xcm.LCD with configuration, download, monitoring, etc.
Update Device via
USB
Update Application
Firmware
Version 1
NOTE!
This procedure applies to version 1, which provides a Home
Page button labeled “Unit Config”.
Version 1
Version 2
Use the following procedure to update the xcm.LCD application with a
USB drive.
An alternate procedure for downloading files is to transfer files to the
xcm.LCD device and upgrade the application via the Opus Supervisor
(see section titled “Update via Opus Supervisor”).
XCM LCD- SW INS 6/16/2011
For the latest technical documentation, visit www.novar.com/manuals
4
Part # XCM-LCD-C; XCM-LCD-G; 50028399-001
NOTE!
Download and update may be performed via the USB method
or via the Opus Supervisor. There is no need to do both.
Step Table
Step
1
2
Procedure
Insert blank USB drive into PC.
Copy the files located under the Applications folder
(PanoramaApp.exe, PanoramaUILibraryCE.dll and Splash.png)
onto the root directory of the USB drive.
Figure 6. Location of Applications folder
XCM LCD- SW INS 6/16/2011
For the latest technical documentation, visit www.novar.com/manuals
5
Part # XCM-LCD-C; XCM-LCD-G; 50028399-001
3
Copy the files located under the Images folder onto the root directory
of the USB drive and then insert the drive into the USB port of the
xcm.LCD device.
Figure 7. Location of Images folder
4
5
If the device is new, the unit will power up in a state searching for a
USB drive to be inserted and will automatically load application
software. If the device already shows a home page then go to the
next step.
Navigate to the Unit Config button (via the Home page), select the
Administration button, and then select Upgrade Unit.
NOTE!
Do not remove the drive from the USB port during
this process. Allow unit to reboot and complete its
download from the Opus Executive Controller (xcm).
NOTE!
The driver file on the xcm (xcmLCD.JAR) must be
V-2.0 or higher. Check the Platform > Software
Manager to verify the version of the driver.
XCM LCD- SW INS 6/16/2011
For the latest technical documentation, visit www.novar.com/manuals
6
Part # XCM-LCD-C; XCM-LCD-G; 50028399-001
6
7
8
Once the update has completed the drive can be removed from the
USB port.
Navigate to the Unit Config button (via the Home page), and select
the Platform Settings button.
Page down and verify the expected Software Version number is
displayed
Update Application
Firmware
Version 2
NOTE!
This procedure applies to version 2, which provides a Home
Page button labeled “Platform”.
Version 1
Version 2
Use the following procedure to update the xcm.LCD application with a
USB drive.
An alternate procedure for downloading files is to transfer files to the
xcm.LCD device and upgrade the application via the Opus Supervisor
(see section titled “Update via Opus Supervisor”).
NOTE!
Download and update may be performed via the USB method
or via the Opus Supervisor. There is no need to do both.
Step Table
Step
1
2
Procedure
Insert blank USB drive into PC.
Copy the files located under the Applications folder
XCM LCD- SW INS 6/16/2011
For the latest technical documentation, visit www.novar.com/manuals
7
Part # XCM-LCD-C; XCM-LCD-G; 50028399-001
(PanoramaApp.exe, PanoramaUILibraryCE.dll and Splash.png)
onto the appropriate directory of the USB drive. If xcm.LCD is:
 Version 2.x with color display, create and use \7400
 Version 2.x with gray-scale display, create and use \7401
 See “Upgrade xcm.LCD to Version 2 for Stand-Alone
Displays:” for associated details about the directories.
 The xcm.20R internal color display prefix is \5693
 The xcm.20R internal gray-scale display prefix is \5694
Figure 6. Location of Applications folder
3
Copy the files located under the Images folder onto the appropriate
directory of the USB drive and then insert the drive into the USB
port of the xcm.LCD device.
XCM LCD- SW INS 6/16/2011
For the latest technical documentation, visit www.novar.com/manuals
8
Part # XCM-LCD-C; XCM-LCD-G; 50028399-001
Figure 7. Location of Images folder
4
5
If the device is new, the unit will power up in a state searching for a
USB drive to be inserted and will automatically load application
software. If the device already shows a home page then go to the
next step.
Navigate to the Platform button (via the Home page), select the
Display Utilities button, and then select Upgrade Software.
NOTE!
Do not remove the drive from the USB port during
this process. Allow unit to reboot and complete its
download from the Opus Executive Controller (xcm).
NOTE!
The driver file on the xcm (xcmLCD.JAR) must be
V-2.0 or higher. Check the Platform > Software
Manager to verify the version of the driver.
6
7
8
Once the update has completed the drive can be removed from the
USB port.
Navigate to the Platform button (via the Home page), and select the
Display Info button.
Verify the expected Display Software Version number is displayed
Update Operating
System (Kernel)
Version 1
NOTE!
This procedure applies to version 1, which provides a Home
Page button labeled “Unit Config”.
XCM LCD- SW INS 6/16/2011
For the latest technical documentation, visit www.novar.com/manuals
9
Part # XCM-LCD-C; XCM-LCD-G; 50028399-001
Version 1
Version 2
Use the following procedure to update the Operating System (kernel) in
an xcm.LCD unit with a USB drive.
Step Table
Step
Procedure
1
2
Insert blank USB drive into PC.
Copy the files located under the Kernel folder (NK.nb0) onto the root
directory of the USB drive and then insert the drive into the USB
port of the xcm.LCD device.
Figure 8. Location of Kernel folder
3
If the xcm.LCD device is new, the unit will power up in a state
searching for a USB drive to be inserted and will automatically
XCM LCD- SW INS 6/16/2011
For the latest technical documentation, visit www.novar.com/manuals
10
Part # XCM-LCD-C; XCM-LCD-G; 50028399-001
load the kernel. If the device already displays a home page then go
to the next step.
NOTE!
If the xcm.LCD device is new, its home page will
only display a single Unit Config button.
4
Navigate to the Unit Config button (via the Home page), select the
Administration button, and then select Upgrade Kernel.
NOTE!
Do not remove the drive from the USB port during
this process. Allow unit to reboot and complete its
download from the Opus Executive Controller (xcm).
5
6
7
Once the upgrade has completed the drive can be removed from the
USB port.
Navigate to the Unit Config button (via the Home Page) and select
the Platform Settings button.
Page down using the down arrow and verify the expected O.S.
Version number is displayed.
Update Operating
System (Kernel)
Version 2
NOTE!
This procedure applies to version 2, which provides a Home
Page button labeled “Platform”.
Version 1
Version 2
Use the following procedure to update the Operating System (kernel) in
an xcm.LCD unit with a USB drive.
Step Table
Step
1
Procedure
Insert blank USB drive into PC.
XCM LCD- SW INS 6/16/2011
For the latest technical documentation, visit www.novar.com/manuals
11
Part # XCM-LCD-C; XCM-LCD-G; 50028399-001
2
Copy “NK.nb0”, located under the Kernel folder (C:\Novar\Opus5.4\xcmlcd\kernel) onto the appropriate directory of the USB drive.
If xcm.LCD is:
 Version 2.x with color display, create and use \7400
 Version 2.x with gray-scale display, create and use \7401
 See “Upgrade xcm.LCD to Version 2 for Stand-Alone
Displays:” for associated details about the directories.
 The xcm.20R internal color display prefix is \5693
 The xcm.20R internal gray-scale display prefix is \5694
Figure 8. Location of Kernel folder
3
If the xcm.LCD device is new, the unit will power up in a state
searching for a USB drive to be inserted and will automatically
load the kernel. If the device already displays a home page then go
to the next step.
NOTE!
If the xcm.LCD device is new, its home page will
only display a single Platform button.
4
Navigate to the Platform button (via the Home page), select the
Display Utilities button, and then select Upgrade O.S.
XCM LCD- SW INS 6/16/2011
For the latest technical documentation, visit www.novar.com/manuals
12
Part # XCM-LCD-C; XCM-LCD-G; 50028399-001
NOTE!
Do not remove the drive from the USB port during
this process. Allow unit to reboot and complete its
download from the Opus Executive Controller (xcm).
NOTE!
The driver file on the xcm (xcmLCD.JAR) must be
V-2.0 or higher. Check the Platform > Software
Manager to verify the version of the driver.
5
6
7
Once the upgrade has completed the drive can be removed from the
USB port.
Navigate to the Platform button (via the Home Page) and select the
System Info button.
Verify the expected O.S. Version number is displayed.
XCM LCD- SW INS 6/16/2011
For the latest technical documentation, visit www.novar.com/manuals
13
Part # XCM-LCD-C; XCM-LCD-G; 50028399-001
Update via Opus
Supervisor
Use the following procedure to update the xcm.LCD application or
kernel via the Opus Supervisor.
An alternate procedure for downloading files is to transfer files to the
xcm.LCD device via a USB drive (see section “Upgrade via USB”).
NOTE!
Download and update may be performed via the USB method
or via the Opus Supervisor. There is no need to do both.
Step Table
Step
1
Procedure
Start the Opus Supervisor program.
NOTE!
The driver file on the xcm (xcmLCD.JAR) must be
V-2.0 or higher. Check the Platform > Software
Manager to verify the version of the driver.
2
3
Navigate to the desired Opus Executive Controller (xcm) station.
Connect to the Platform, expand the Platform node in the Opus
Explorer, and select File Transfer Client.
The following screen will appear; files on the local system are
displayed in the left-side pane and files on the Opus Executive
Controller (xcm) are displayed in the right-side pane.
XCM LCD- SW INS 6/16/2011
For the latest technical documentation, visit www.novar.com/manuals
14
Part # XCM-LCD-C; XCM-LCD-G; 50028399-001
Figure 9. “Files on this Computer”
4
In the left-side pane, navigate to the xcmLCD folder under the Opus
Supervisor installation.
Example: C:/Novar/Opus-5.0.2/xcmLCD
5
In the right-side pane, double-click on the niagara folder and then on
the stations folder. A folder matching the name of the xcm’s
station will be shown.
Figure 10. Location of stations folder
6
7
In the right-side pane, double-click on the station folder; a list of the
station’s folders and files will be displayed.
In the right-side pane, right-click in the open area and select Create
subdirectory. Name the subdirectory xcmLCD.
NOTE!
If the xcmLCD subdirectory already exists, do not
create another, just proceed to the next step.
XCM LCD- SW INS 6/16/2011
For the latest technical documentation, visit www.novar.com/manuals
15
Part # XCM-LCD-C; XCM-LCD-G; 50028399-001
Figure 11. Create subdirectory action
Figure 12. Naming subdirectory folder
8
In the right-side pane, double-click on the new xcmLCD folder.
Figure 13. New subdirectory folder
9
In the left-side pane, highlight the Applications folder. Click on the
transfer button (right arrow between the left and right panes) to
initiate a file transfer. Upon completion, an Applications folder
will appear in the right-side pane.
10
In the left-side pane, highlight the kernel folder. Click on the transfer
button (right arrow between the left and right panes) to initiate a
file transfer. Upon completion, a kernel folder will appear in the
right-side pane.
XCM LCD- SW INS 6/16/2011
For the latest technical documentation, visit www.novar.com/manuals
16
Part # XCM-LCD-C; XCM-LCD-G; 50028399-001
Figure 14. Device Status screen
11
In the NavTree, navigate to the xcm.LCD in the station that needs to
be upgraded. Access this display by:
Example: Station -> Config -> Drivers ->
XCMDisplayNetwork_COMx -> XCM display
12
NOTE!
The driver file on the xcm (xcmLCD.JAR) must be
V-2.0 or higher. Check the Platform > Software
Manager to verify the version of the driver.
Right click on the xcm.LCD. Select Actions then select Upgrade
Application or Upgrade Kernel. This will initiate the application
upgrade of the unit.
Figure 15. Upgrade Applications action
13
Viewing the Download State in the Device Status container will
show the progress of the download. Access this display by:
Example: Station -> Config -> Drivers ->
XCMDisplayNetwork_COMx -> XCM-LCD_1 -> Device Status
XCM LCD- SW INS 6/16/2011
For the latest technical documentation, visit www.novar.com/manuals
17
Part # XCM-LCD-C; XCM-LCD-G; 50028399-001
Figure 16. Device Status screen
14
Navigate to the Device Info container and verify the expected
Application Version number is displayed. Access this display by:
Example: Station -> Config -> Drivers ->
XCMDisplayNetwork_COMx -> XCM-LCD_1 -> Device Info
Figure 17. View of Version number in Device Information
XCM LCD- SW INS 6/16/2011
For the latest technical documentation, visit www.novar.com/manuals
18
Part # XCM-LCD-C; XCM-LCD-G; 50028399-001
Upgrade Version 1
to Version 2 via
USB drive
(Stand-Alone
Displays)
This procedure applies to existing, installed (Version 1) xcm.LCD
displays that you wish to update to Version 2. It uses a USB drive
(plugged into the display – lower left corner) to implement the upgrade.
Step Table
1
Place Nk.nb0 on root directory of the USB drive
Figure 18. Root file
2
Place version 2.xx.xx PanoramaApp.exe and
PanoramaUILibraryCE.dll files on the root directory of the USB
drive. For color displays create a subdirectory called "7400" on the
USB drive and place the executable and dll files there, also. For
grayscale displays create a subdirectory called "7401" on the USB
drive and place the executable and dll files there, also.
XCM LCD- SW INS 6/16/2011
For the latest technical documentation, visit www.novar.com/manuals
19
Part # XCM-LCD-C; XCM-LCD-G; 50028399-001
3
With the display powered, plug in the USB drive. Take note of the
display’s address for step #7.
Figure 19. Address
4
Navigate to Administration and select Upgrade Kernel
Figure 20. Upgrade Kernel
5
Enter the appropriate access code to start the kernel upgrade process
NOTE!
“Super User” access is required to initiate a kernel
upgrade. If a super user account does not exist,
please add one (create new or change existing) before
attempting the upgrade.
6
After the kernel loads the display will restart and it will automatically
pick up the new application files during the boot sequence. If the
display has a serial number programmed in, the boot process will
attempt to load the PanoramaApp.exe and
PanoramaUILibraryCE.dll files from the directory on the USB
drive that matches the 4-character serial number prefix of the
XCM LCD- SW INS 6/16/2011
For the latest technical documentation, visit www.novar.com/manuals
20
Part # XCM-LCD-C; XCM-LCD-G; 50028399-001
7
display (either 7400 or 7401).
Verify that the address of the display is at 0 and change it back to
what it was before the upgrade. The display will be in “LCD
Fault” because it cannot communicate with the xcm using address
0. Use the setup password (9999) to change it back to the proper
setting. The display will then automatically request a new layout
download and get the display’s clock updated.
NOTE!
The driver file on the xcm (xcmLCD.JAR) must be
V-2.0 or higher. Check the Platform > Software
Manager to verify the version of the driver.
8
9
10
Since the boot loader cannot be upgraded the display will not show
the Novar splash screen on power up.
Remove the USB drive from the display.
The upgrade process will leave an “upgraded.txt” file on the USB
drive if completed successfully. You must delete that file if the
USB drive will be used to upgrade another display.
Upgrade Version 1
to Version 2 via
Opus Supervisor
This procedure applies to existing, installed (Version 1) xcm.LCD
displays that you wish to update to Version 2. It uses the Opus
supervisor, remotely connected to the Opus Executive Controller (xcm),
to implement the upgrade.
Very important note – The steps of this procedure must be done in the
order shown. If done in a different order, you will not be able to
complete the upgrade and will need to visit the site to correct the
installation. If this happens, use the USB procedure to start-over and
complete the installation.
Make sure the station and supervisor that are supporting the xcm.LCD
display(s) have been upgraded to the latest xcmLCD driver (v2.0.6 or
greater). The xcm.LCD driver must be upgraded first before doing this
procedure. Use the platform “Software Manager” to verify the xcm.LCD
driver is current.
XCM LCD- SW INS 6/16/2011
For the latest technical documentation, visit www.novar.com/manuals
21
Part # XCM-LCD-C; XCM-LCD-G; 50028399-001
Do not add any new xcm.LCD screen display elements until after all of
the displays have been upgraded. During the upgrade process, the
xcm.LCD screens must be from version 1.
To quicken the upgrade process you can enable only the display being
upgraded and disable all other on the xcm. Be aware that a remote
kernel upgrade to one active display will take approximately 2 hours to
complete.
Since the boot loader cannot be remotely upgraded an upgraded display
will not show the new “Novar” splash screen on power up.
Step
1
2
3
Procedure
Start the Opus Supervisor program. Follow this procedure to ensure:
-
Version 2 xcm.LCD applications and UI library files have been
transferred to the station’s platform and placed in the
\xcmLCD\applications directory.
-
v2.01.00118 kernel file “nk.nb0.gz” (or greater) has been
transferred to the station’s platform and placed in the
\xcmLCD\kernel directory.
Navigate to the desired Opus Executive Controller (xcm) station.
Connect to the Platform, expand the Platform node in the Opus
Explorer, and select File Transfer Client.
The following screen will appear; files on the local system are
displayed in the left-side pane and files on the Opus Executive
Controller (xcm) are displayed in the right-side pane.
Figure 9. “Files on this Computer”
XCM LCD- SW INS 6/16/2011
For the latest technical documentation, visit www.novar.com/manuals
22
Part # XCM-LCD-C; XCM-LCD-G; 50028399-001
4
In the left-side pane, navigate to the xcmlcd/kernel folder under the
Opus Supervisor installation.
Example: C:/Novar/Opus-5.4/xcmlcd/kernel
Figure 9. “Files on this Computer”
5
In the right-side pane, double-click on the niagara folder and then on
the stations folder. A folder matching the name of the xcm’s
station will be shown.
Figure 10. Location of stations folder
6
7
In the right-side pane, double-click on the station folder; a list of the
station’s folders and files will be displayed.
In the right-side pane, right-click in the open area and select Create
subdirectory. Name the subdirectory xcmLCD.
NOTE!
If the xcmLCD subdirectory already exists, do not
create another, just proceed to the next step.
XCM LCD- SW INS 6/16/2011
For the latest technical documentation, visit www.novar.com/manuals
23
Part # XCM-LCD-C; XCM-LCD-G; 50028399-001
Figure 11. Create subdirectory action
Figure 12. Naming subdirectory folder
8
In the right-side pane, double-click on the new xcmLCD folder.
XCM LCD- SW INS 6/16/2011
For the latest technical documentation, visit www.novar.com/manuals
24
Part # XCM-LCD-C; XCM-LCD-G; 50028399-001
Figure 13. New subdirectory folder
9
In the left-side pane, highlight the Applications folder. Click on the
transfer button (right arrow between the left and right panes) to
initiate a file transfer. Upon completion, an Applications folder
will appear in the right-side pane.
NOTE:
If the “Applications” folder already existed, then
copy the contents of “C:/Novar/Opus5.4/xcmlcd/applications” to the applications folder of
the xcm.
10
In the left-side pane, highlight the kernel folder. Click on the transfer
button (right arrow between the left and right panes) to initiate a
file transfer. Upon completion, a kernel folder will appear in the
right-side pane.
Figure 14. Device Status screen
XCM LCD- SW INS 6/16/2011
For the latest technical documentation, visit www.novar.com/manuals
25
Part # XCM-LCD-C; XCM-LCD-G; 50028399-001
NOTE:
If the “kernel” folder already existed, then copy the
contents of “C:/Novar/Opus-5.4/xcmlcd/kernel” to
the kernel folder of the xcm.
11
In the NavTree, navigate to the xcm.LCD in the station that needs to
be upgraded. Access this display by:
Example: Station -> Config -> Drivers ->
XCMDisplayNetwork_COMx -> XCM display
12
NOTE!
The driver file on the xcm (xcmLCD.JAR) must be
V-2.0 or higher. Check the Platform > Software
Manager to verify the version of the driver.
Right click on the xcm.LCD. Select Actions then select Upgrade
Application. This will initiate the application upgrade of the unit.
“Upgrade Application” must be done before “Upgrade Kernel”.
Figure 15. Upgrade Application
Open the display’s property sheet and expand the Device Status
property to view the progress of the application upgrade. A layout
download will accompany the application upgrade. This upgrade
should only take a few minutes.
XCM LCD- SW INS 6/16/2011
For the latest technical documentation, visit www.novar.com/manuals
26
Part # XCM-LCD-C; XCM-LCD-G; 50028399-001
Figure 16. Device Status
After the application upgrade completes the version may be checked
by accessing Device Info on the property sheet for the display just
upgraded. It should indicate that the application version is
“v2.00.8” or greater.
Figure 17. Device Info
When the applications upgrade completes, return to the XCM display
and right click on the xcm.LCD. Select Actions then select
Upgrade Kernel. This will initiate the kernel upgrade of the unit.
Open the display’s property sheet and expand the Device Status
property to view the progress of the kernel upgrade file transfer. A
layout download will accompany the kernel upgrade when the
display restarts. Use the same method described above to monitor
the progress of the upgrade.
Verify the versions of the application and kernel by viewing the
Device Info property.
Repeat these steps for each of the displays supported by the station.
Make sure to access each display’s property sheet and set their
Enabled property to true after the last display finishes its kernel
upgrade.
XCM LCD- SW INS 6/16/2011
For the latest technical documentation, visit www.novar.com/manuals
27
Part # XCM-LCD-C; XCM-LCD-G; 50028399-001
Opus™ and EZ-Nav™ are registered trademarks of Honeywell International
The material in this document is for information purposes only. The content and the product it describes
are subject to change without notice. Novar makes no representations or warranties with respect to this document.
In no event shall Novar be liable for technical or editorial omissions or mistakes in this document, nor shall it be liable
for any damages, direct or incidental, arising out of or related to the use of this document. No part of this document
may be reproduced in any form or by any means without prior written permission from Novar.
Copyright © 2011 by Honeywell International, Inc.. All Rights Reserved.
Novar
6060 Rockside Woods Blvd.,
Cleveland, OH 44131
Phone: 1.800.348.1235
www.novar.com
XCM LCD- SW INS 6/16/2011
For the latest technical documentation, visit www.novar.com/manuals
28
Download PDF