Gryphon™ I GM410X
General Purpose Handheld
Linear Imager Barcode Reader
with Datalogic’s STAR Cordless System™
Quick Reference Guide
Datalogic ADC, Inc.
959 Terry Street
Eugene, OR 97402
USA
Telephone: (541) 683-5700
Fax: (541) 345-7140
©2009-2014 Datalogic ADC, Inc.
An Unpublished Work - All rights reserved. No part of the contents
of this documentation or the procedures described therein may be
reproduced or transmitted in any form or by any means without
prior written permission of Datalogic ADC, Inc. or its subsidiaries or
affiliates ("Datalogic" or "Datalogic ADC"). Owners of Datalogic
products are hereby granted a non-exclusive, revocable license to
reproduce and transmit this documentation for the purchaser's
own internal business purposes. Purchaser shall not remove or
alter any proprietary notices, including copyright notices, contained in this documentation and shall ensure that all notices
appear on any reproductions of the documentation.
Should future revisions of this manual be published, you can
acquire printed versions by contacting your Datalogic representative. Electronic versions may either be downloadable from the
Datalogic website (www.datalogic.com) or provided on appropriate
media. If you visit our website and would like to make comments
or suggestions about this or other Datalogic publications, please
let us know via the "Contact Datalogic" page.
Disclaimer
Datalogic has taken reasonable measures to provide information
in this manual that is complete and accurate, however, Datalogic
reserves the right to change any specification at any time without
prior notice.
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. All
other brand and product names may be trademarks of their
respective owners.
Patents
This product may be covered by one or more of the following
patents:
Design Patents: CN ZL200830142386.5; CN
ZL200930006852.1; CN ZL201030175545.9; EP870787;
EP1177943; USD599799; USD606076; USD629003
Utility Patents: CN ZL200680050007.8; EP0789315B1;
EP0926620B1; EP0997760B1; EP1128314B1; EP1128315B1;
EP1164536B1; EP1217571B1; EP1396811B1; EP1413971B1;
EP1804089B1; EP1942442B1; US5481098; US5493108;
US5992740; US6098883; US6260764; US6443360; US6454168;
US6494376; US6517003; US6561427; US6808114; US6871785;
US6997385; US7075663; US7387246; US8113430; USRE41349.
Additional patents pending.
Table of Contents
Software Product Policy .............................................................................. 4
Customers Under Software Support ........................................... 4
Setting Up the Reader ................................................................................. 5
Star Models and Frequency ................................................. 5
Configure the Base Station ....................................................................... 6
Changing the Base Station Position ............................................ 6
Connecting the Base Station .......................................................... 8
Securing the DC Power Cord (Optional) ......................... 8
Using the BC40xx™ Radio Base ...............................................................11
Base LEDs .............................................................................................11
Display ..................................................................................................12
Charging the Batteries ...............................................................................13
Battery Safety .....................................................................................13
Replacing the Batteries ..................................................................16
Linking the Reader to a Base Station ....................................................18
RF Devices ...........................................................................................18
System and Network Layouts .................................................................18
Stand Alone Layouts .......................................................................18
Select the Interface Type ..........................................................................20
Interface Selection ...........................................................................20
Configuring the Interface ..............................................................20
Keyboard Interface .....................................................................................25
Standard Factory Settings .............................................................25
Scancode Tables ...............................................................................25
Country Mode ...............................................................................................25
Caps Lock State ............................................................................................30
Numlock ..........................................................................................................31
Programming ................................................................................................32
Using the Programming Barcodes .............................................32
Configure Other Settings.................................................... 32
Resetting Standard Product Defaults............................. 32
Technical Specifications ............................................................................33
LED and Beeper Indications .....................................................................36
Error Codes ....................................................................................................38
Base Station Indications ............................................................................39
Ergonomic Recommendations ...............................................................40
Cleaning ..........................................................................................................40
Regulatory Information .............................................................................41
Statement of Agency Compliance .............................................41
FCC Class B Compliance Statement ...........................................41
FCC RF Radiation Exposure Statement .......................... 41
Canadian Notice..................................................................... 42
Power Supply .....................................................................................42
Imager Labeling ................................................................................47
Warranty .........................................................................................................48
NOTES
Datalogic ADC, Inc.
GRYPHON™ PRODUCT SERIES
END USER LICENSE AGREEMENT
Notice to End User: The Datalogic Product you have acquired contains embedded Software, which is integral to the product's operation. This Software is
being provided to you under license, subject to the terms and conditions of this
Agreement. If you use the Datalogic Product, you will be deemed to have
accepted the terms and conditions of this Agreement. If you do not intend to be
bound to the terms of this Agreement, Datalogic is not willing to license the
Software to you, you may not use the Datalogic Product or the Software, and
you must contact the party from whom you acquired the Datalogic Product for
instructions.
This End User Software License Agreement ("Agreement") is a legally binding agreement governing the licensing of the Software and Documentation by Datalogic ADC,
Inc. and its Affiliates ("Datalogic") to the entity or person who has purchased or otherwise acquired a Datalogic Product ("End User"). For purposes of this Agreement, any
software that is associated with a separate end-user license agreement is licensed to
you under the terms of that license agreement. Datalogic and End User hereby agree
as follows:
1. Definitions.
1.1 "Affiliate" means a business entity currently existing or later acquired that controls,
is controlled by, or is under common control with Datalogic S.p.A.
1.2 "Documentation" means materials such as user's guides, program reference
guides, quick reference guides, manuals, or similar materials associated with or
related to the Datalogic Product, whether in printed, "online", or other form.
1.3 "Proprietary Information" means: (a) source code, object code, software, documentation, and any related internal design, system design, data base design,
algorithms, technology, technical data or information, implementation techniques, and trade secrets related to the Software, (b) any other trade secrets
marked appropriately or identified as proprietary or confidential, and (c) any
information that End User, under the circumstances, should recognize as confidential. Proprietary Information does not include any information that the
receiving party can establish was (1) in the public domain, (2) already in the
receiving party's possession or rightfully known prior to receipt, (3) rightfully
learned from a third party not in violation of any other's proprietary rights, or
(4) independently developed without access to Proprietary Information.
1.4 "Datalogic Product" means the Datalogic® Gryphon™ series scanner product,
including all embedded Software in and all Documentation related to such
product, which has been purchased or otherwise acquired by End User,
whether obtained directly or indirectly from Datalogic.
1.5 "Software" means any software or computer programs of Datalogic or its third
party licensors in machine readable form which is embedded in the Datalogic
Product, whether obtained directly or indirectly from Datalogic, including any
replacement, update, upgrade, enhancement or modification.
2. Scope Of License Granted.
2.1 Datalogic grants to End User a non-exclusive, non-transferable, perpetual license
to use the Software, solely on the Datalogic Product in which it is embedded
("designated Datalogic Product"), in machine-readable form only, solely for
End User's internal business purposes. This Agreement does not convey ownership of the Software to End User. Title to the Software shall be and remain
with Datalogic or the third party from whom Datalogic has obtained a licensed
right. As used in this Agreement, the term "purchase" or its equivalents when
applied to the Software shall mean "acquire under license." End User is not
entitled to receipt or use of the source code to any Software.
2.2
End User shall not copy, modify, decompile, disassemble, reverse engineer, or
otherwise reproduce or remanufacture the Software, whether modified or
unmodified, nor sell, assign, sublicense, distribute, lend, rent, give, or otherwise transfer the Software to any other person or organization, for purposes
other than as expressly provided in this Agreement, without Datalogic's prior
written consent.
3. Transfers, Support.
3.1
Any copying, installing, reproduction, remanufacture, reverse engineering,
electronic transfer, or other use of the Software on other than the designated
Datalogic Product will be a material breach of this Agreement. However, Data-
Quick Reference Guide
1
3.2
3.3
logic may elect not to terminate this Agreement or the granted licenses, but
instead may elect to notify End User that End User is deemed to have ordered
and accepted a license for each breaching use. End User shall pay Datalogic
the applicable list price for such licenses as of the date of such breach.
End User shall not sell, assign, sublicense, distribute, lend, rent, give, or otherwise transfer the Datalogic Product to any third party unless such third party
agrees with Datalogic in writing to be bound by the terms and conditions of
this Agreement. Any such transfer of the Datalogic Product absent such agreement shall be null and void.
End User may obtain support for Software from Datalogic at Datalogic's standard support fees and under Datalogic's standard support terms and conditions in effect at the time the support is requested.
4. Intellectual Property.
End User acknowledges that the Software constitutes valuable trade secrets of Datalogic or Datalogic's third party licensors and that the Software is protected by intellectual property laws and treaties. The license set forth in this Agreement does not transfer
to End User any ownership of Datalogic's or its third party licensors' copyrights, patents,
trademarks, service marks, trade secrets, or other intellectual property rights and End
User shall have no right to commence any legal actions to obtain such rights. End User
shall not remove, modify, or take any other action that would obscure any copyright,
trademark, patent marking, or other intellectual property notices contained in or on the
Datalogic Product.
5. Proprietary Information.
5.1
5.2
5.3
End User acknowledges that Proprietary Information is the confidential, proprietary, and trade secret property of Datalogic and Datalogic's third party
licensors and End User acquires no right or interest in any Proprietary Information.
End User shall not disclose, provide, or otherwise make available the Proprietary Information of Datalogic or its third party licensors to any person other
than End User's authorized employees or agents who are under confidentiality
agreement, and End User shall not use the Proprietary Information other than
in conjunction with use of the Datalogic Product exclusively for End User's
internal business purposes. End User shall take steps to protect the Proprietary
Information no less securely than if it were End User's own intellectual property.
The provisions of this Proprietary Information Section shall survive and continue for five (5) years after the termination of this Agreement.
6. Limited Warranty.
6.1
6.2
Datalogic warrants that, under normal use and operation, the Datalogic Product will conform substantially to the applicable Documentation for the period
specified in the Documentation. During this period, for all reproducible nonconformities for which Datalogic has been given written notice, Datalogic will
use commercially reasonable efforts to remedy nonconformities verified by
Datalogic. End User agrees to supply Datalogic with all reasonably requested
information and assistance necessary to help Datalogic in remedying such
nonconformities. For all defects reported to Datalogic within the warranty
period, Datalogic's liability is limited to providing End User with one copy of
corrections or responding to End User's problem reports according to Datalogic's standard assistance practices. Datalogic does not warrant that the product will meet End User's requirements or that use of the product will be
uninterrupted or error free, or that Datalogic's remedial efforts will correct any
nonconformance. This limited warranty does not cover any product that have
been subjected to damage or abuse, whether intentionally, accidentally, or by
neglect, or to unauthorized repair or unauthorized installation, and shall be
void if End User modifies the product, uses the product in any manner other
than as established in the Documentation, or if End User breaches any of the
provisions of this Agreement.
EXCEPT AS PROVIDED IN THIS AGREEMENT, THE DATALOGIC PRODUCT IS PROVIDED "AS IS" AND DATALOGIC MAKES NO WARRANTIES OF ANY KIND,
EXPRESS OR IMPLIED, WRITTEN OR ORAL, WITH RESPECT TO THE PRODUCT,
AND SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
7. Infringement.
7.1
2
Datalogic will defend End User against any claim in a lawsuit that the Datalogic
Product furnished hereunder infringe a United States patent or copyright of a
third party and Datalogic will pay any damages finally awarded against End
User by a court of competent jurisdiction that are attributable to such claim or
will pay End User's part of any settlement that is attributable to such claim,
Gryphon™ I GM410X
7.2
7.3
7.4
provided, that 1) End User notifies Datalogic promptly in writing of the claim,
2) Datalogic controls the defense or settlement of the claim, and 3) End User
cooperates fully with Datalogic in such defense or settlement. All notices of a
claim should be sent to Datalogic ADC, Inc., Legal Department, 959 Terry
Street, Eugene, OR 97402.
In the defense or settlement of any such claim, Datalogic may, at its option, 1)
procure for End User the right to continue using the Datalogic Product, 2)
modify the Datalogic Product so that it becomes non-infringing, 3) replace the
Datalogic Product with an equivalent product not subject to such claim, or 4)
provide End User an opportunity to return the Datalogic Product and receive a
refund of the purchase price paid, less a reasonable allowance for use.
Datalogic shall have no liability to End User for claims of infringement based
upon 1) the use of any Datalogic Product in combination with any product
which Datalogic has not either furnished or authorized for use with such Datalogic Product 2) the use of any Datalogic Product designed, manufactured, or
modified to the specifications of End User, or 3) End User's modification of the
Datalogic Product without written authorization from Datalogic.
THE FOREGOING STATES DATALOGIC'S COMPLETE AND ENTIRE OBLIGATION
CONCERNING CLAIMS OF PATENT, COPYRIGHT, OR OTHER INTELLECTUAL
PROPERTY INFRINGEMENT, CANCELS AND SUPERCEDES ANY PRIOR AGREEMENTS, WHETHER ORAL OR WRITTEN, BETWEEN THE PARTIES CONCERNING
SUCH CLAIMS, AND WILL NOT BE MODIFIED OR AMENDED BY ANY PAST, CONTEMPORANEOUS, OR FUTURE AGREEMENTS OR DEALINGS BETWEEN THE PARTIES, WHETHER ORAL OR WRITTEN, EXCEPT AS SET FORTH IN A FUTURE
WRITING SIGNED BY BOTH PARTIES.
8. Limitation Of Liability.
EXCEPT AS PROVIDED IN SECTION 7, DATALOGIC SHALL NOT BE LIABLE FOR ANY CLAIMS
AGAINST END USER BY ANY OTHER PARTY. IN NO EVENT SHALL DATALOGIC'S LIABILITY
FOR DAMAGES, IF ANY, WHETHER BASED UPON CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, STRICT LIABILITY, WARRANTY, OR ANY OTHER BASIS,
EXCEED THE PRICE OR FEE PAID BY END USER FOR THE DATALOGIC PRODUCT. UNDER NO
CIRCUMSTANCES SHALL DATALOGIC BE LIABLE TO END USER OR ANY THIRD PARTY FOR
LOST PROFITS, LOST DATA, INTERRUPTION OF BUSINESS OR SERVICE, OR FOR ANY OTHER
SPECIAL, CONSEQUENTIAL, CONTINGENT, INDIRECT, INCIDENTAL, PUNITIVE, EXEMPLARY,
OR OTHER SIMILAR DAMAGES, EVEN IF DATALOGIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
9. Government Restricted Rights; International Use.
9.1
9.2
Use, duplication, or disclosure of the Software by the U.S. Government is subject to the restrictions for computer software developed at private expense as
set forth in the U.S. Federal Acquisition Regulations at FAR 52.227-14(g), or
52.227-19 or in the Rights in Technical Data and Computer Software clause at
DFARS 252.227-7013(c)(1)(ii), whichever is applicable.
If End User is using the Datalogic Product outside of the United States, End
User must comply with the applicable local laws of the country in which the
Datalogic Product is used, with U.S. export control laws, and with the English
language version of this Agreement. The provisions of the "United Nations
Convention on International Sale of Goods" shall not apply to this Agreement.
10. Termination.
10.1
10.2
Either party may terminate this Agreement or any license granted under this
Agreement at any time upon written notice if the other party breaches any
provision of this Agreement.
Upon termination of this Agreement, End User immediately shall cease using
any nonembedded software and shall return to Datalogic or destroy all nonembedded software covered by this Agreement, and shall furnish Datalogic
with a certificate of compliance with this provision signed by an officer or
authorized representative of End User. For embedded software, End User
agrees to sign a waiver prepared by Datalogic concerning further use of the
embedded Software. End User's resumed or continued use of the embedded
Software after termination shall constitute End User's agreement to be bound
by the terms and conditions of this Agreement for such use.
11. General Provisions.
11.1 Entire Agreement; Amendment. This document contains the entire agreement
between the parties relating to the licensing of the Software and supersedes
all prior or contemporaneous agreements, written or oral, between the parties
concerning the licensing of the Software. This Agreement may not be
changed, amended, or modified except by written document signed by Datalogic.
11.2 Notice. All notices required or authorized under this Agreement shall be given in
Quick Reference Guide
3
Software Product Policy
writing, and shall be effective when received, with evidence of receipt. Notices
to Datalogic shall be sent to the attention of Contract Administration, Datalogic ADC, Inc., 959 Terry Street, Eugene, OR 97402, or such other address as
may be specified by Datalogic in writing.
11.3 Waiver. A party's failure to enforce any of the terms and conditions of this Agreement shall not prevent the party's later enforcement of such terms and conditions.
11.4 Governing Law; Venue: This Agreement and the rights of the parties hereunder
shall be governed by and construed in accordance with the laws of the State of
Oregon U.S.A, without regard to the rules governing conflicts of law. The state
or federal courts of the State of Oregon located in either Multnomah or Lane
counties shall have exclusive jurisdiction over all matters regarding this Agreement, except that Datalogic shall have the right, at its absolute discretion, to
initiate proceedings in the courts of any other state, country, or territory in
which End User resides, or in which any of End User's assets are located.
11.5 Attorneys' Fees. In the event an action is brought to enforce the terms and conditions of this Agreement, the prevailing party shall be entitled to reasonable
attorneys' fees, both at trial and on appeal.
- END -
Software Product Policy
Datalogic reserves the right to ship its products with the latest
version of software/firmware available. This provides our customers with the very latest in Datalogic software technology.
The only exception to this policy is when the buyer has a signed
contract with Datalogic that clearly defines the terms and conditions for making software/firmware changes in products shipped
to the buyer.
Customers Under Software Support
Customers that elect to subscribe to Datalogic Software Maintenance and Support Agreement will receive 30 days advance notification of: (1) the release of a new software version; and/or (2)
discontinuation of any prior software version that will no longer
be supported. Datalogic will provide maintenance for a fee that
will assist customers in transitioning to the next software version.
If a customer is currently using the software version being discontinued, the customer may elect to transition to any one of the
newer versions, depending on the hardware in use.
To arrange for a Software Maintenance and Support Agreement
please contact your Datalogic sales person.
4
Gryphon™ I GM410X
Gryphon™ I GM410X
Quick Reference Guide
Setting Up the Reader
Follow the steps below to connect and get your reader up and
communicating with its host.
1.
Configure the Base Station starting on this page.
2.
Charge the Batteries (see page 12).
3.
Link to the Base Station (see page 17).
4.
Select the Interface Type (see page 19).
5.
Configure other settings if desired starting on page 31
(optional, depends on settings needed).
Configure the Base Station
The base charger/station may be configured in desk application to
hold the reader in two different positions, either a horizontal or
standing position, in order to provide the most comfortable use
depending on needs.
Standing
Horizontal
Changing the Base Station Position
The base station is configured by installing one of two sets of mechanical parts that come with the cordless kit. The default mounts
(shown below) provide three options: vertical (wall) mounting,
standing (45°), or horizontal mounting with a higher mechanical
retention of the scanner. Use the other mounts only for horizontal
mounting, with lower retention of the scanner. The different
Quick Reference Guide
5
Configure the Base Station
parts may be interchanged to customize retention preferences.
A tool such as a rigid pen or a flat screwdriver can be used
to change the mounts. Do not allow it to touch the contacts.
1.
Insert the appropriate parts for the desired base station
position, as shown below.
Standing,
Horizontal
or Vertical
2.
Horizontal
Only
Using your thumbs, push open the plastic tabs on the
bottom of the base to free the wing holders.
Tab
Tab
To ensure best contact and performance, do not intermix the parts of the two different mount sets.
CAUTION
6
Gryphon™ I GM410X
Configure the Base Station
3.
The stand can now be repositioned in either horizontal
or standing position.
Horizontal
Standing
Connecting the Base Station
Figure 1 shows how to connect the Base Station to a terminal, PC
or other host device. Turn off the host before connection and consult the manual for that equipment (if necessary) before proceeding. Connect the interface cable before applying power to the Base
Station.
The Gryphon GM410X can also be Powered by the Terminal.
When powered by the Terminal, the battery charger is
automatically set as Slow charge.
For some specific interfaces or hosts or lengths of cable, the
use of an external power supply may be recommended for
full recharging capability (see Technical Specifications on
page 32 for more details).
Base Station Connection and Routing: Fully insert the Power Cable and Interface (I/F) Cable connectors into their respective ports
in the underside of the Base Station (see Figure 1). Then connect
to an AC Adapter, and plug the AC power cord into the (wall)
outlet.
Quick Reference Guide
7
Configure the Base Station
Figure 1. Connecting the Base Station
Wall plug
Connector
I/F Cable
AC/DC
Adapter
DC Power
Cord
Base
Station
Securing the DC Power Cord (Optional)
The DC power cord for the adapter can be secured to the bottom
of the base in order to maximize the mechanical retention of the
cable itself. The routing of the power cord can be changed to accommodate the base station positioning: horizontal, stand or wall
mounting. The cables can be looped around to the front of the
Base Station, or fed directly out the back of the Base Station, as
shown in Figure 2 on page 8.
Figure 2. Options for routing the DC cord
Please refer to the arrows depicted on the bottom of the base when
placing the cables, detailed in Figure 3.
8
Gryphon™ I GM410X
Configure the Base Station
Figure 3. Arrows showing routing
Host Connection: Verify before connection that the reader’s cable
type is compatible with your host equipment. Most connections
plug directly into the host device as shown in Figure 4 on page 9.
Keyboard Wedge interface cables have a ‘Y’ connection where its
female end mates with the male end of the cable from the keyboard and the remaining end at the keyboard port on the terminal/PC.
B
Figure 4. Connecting to the Host
Wa
Ke W
nd
US
or...
yb
ed oard
g
or... e
M
or...
IB
Power Connection : Plug the AC Adapter in to an approved AC
wall socket with the cable facing downwards (as shown in Figure
1) to prevent undue strain on the socket.
Quick Reference Guide
9
Using the BC40xx™ Radio Base
Disconnecting the Cable: To detach the cable, insert a paper clip
or similar object into the hole on the base, as shown in Figure 5.
Figure 5. Disconnecting the Cable
Insert
Paper Clip
Using the BC40xx™ Radio Base
Base LEDs
LEDs on the Gryphon I Base provide information about the
Base’s status, as shown in Figure 6.
Figure 6. Gryphon I Base LEDs
YELLOW LED
BUTTON
RED LED —
GREEN LED
10
Gryphon™ I GM410X
Using the BC40xx™ Radio Base
The following table describes the significance of each LED:
LED
STATUS
Power on / Data
Yellow On = Base is powered
Yellow Blinking = Base receives data and
commands from the Host or the Reader.
Charging
Red On = the Battery is in progress.
Charge completed Green On = the Battery is completely charged.
Charging +
Red and Green Blinking together = the Reader
Charge completed is not correctly placed onto the Base.
A button is available to force device connection via the Datalogic
Aladdin Software tool, and for paging the scanner when bidirectional connection is activated. Refer to the Gryphon I Product
Reference Guide (PRG) for a more detailed explanation.
Display
The Gryphon I is also available with an optional Display. The
FSTN Display with white LED backlight provides additional information.
Figure 7. Gryphon™ I Display
Quick Reference Guide
11
Charging the Batteries
Charging the Batteries
To charge the battery, simply insert the Gryphon into the base.
When the scanner is fully seated in the cradle, it will sound a
“chirp” to indicate that the cradle has detected the scanner connection.
Before using the Battery, read “Battery Safety” in the following section. Datalogic recommends annual replacement of rechargeable battery packs to ensure maximum
performance.
Battery Safety
To install, charge and/or do any other action on the battery, follow the instructions in this manual.
WARNING
Do not discharge the battery using any device except for
the scanner. When the battery is used in devices other
than the designated product, it may damage the battery
or reduce its life expectancy. If the device causes an abnormal current to flow, it may cause the battery to become
hot, explode or ignite and cause serious injury.
Lithium-ion battery packs may get hot, explode or ignite
and cause serious injury if exposed to abusive conditions.
Be sure to follow the safety warnings listed on the following page.
• Do not place the battery pack in fire or heat.
• Do not connect the positive terminal and negative
terminal of the battery pack to each other with any
metal object (such as wire).
WARNING
• Do not carry or store the battery pack together with
metal objects.
• Do not pierce the battery pack with nails, strike it
with a hammer, step on it or otherwise subject it to
strong impacts or shocks.
• Do not solder directly onto the battery pack.
• Do not expose the battery pack to liquids, or allow
the battery to get wet.
• Do not apply voltages to the battery pack contacts.
WARNING
12
In the event the battery pack leaks and the fluid gets into
your eye, do not rub the eye. Rinse well with water and
immediately seek medical care. If left untreated, the battery fluid could cause damage to the eye.
Gryphon™ I GM410X
Charging the Batteries
CAUTION
CAUTION
CAUTION
Always charge the battery at 32° – 104°F (0° - 40°C) temperature range.
Use only the authorized power supplies, battery pack,
chargers, and docks supplied by your Datalogic reseller.
The use of any other power supplies can damage the
device and void your warranty.
Do not disassemble or modify the battery. The battery contains safety and protection devices, which, if damaged,
may cause the battery to generate heat, explode or ignite.
Do not place the battery in or near fire, on stoves or other
high temperature locations.
Do not place the battery in direct sunlight, or use or store
the battery inside cars in hot weather. Doing so may cause
the battery to generate heat, explode or ignite. Using the
battery in this manner may also result in a loss of performance and a shortened life expectancy.
Do not place the battery in microwave ovens, high-pressure containers or on induction cookware.
Immediately discontinue use of the battery if, while using,
charging or storing the battery, the battery emits an
unusual smell, feels hot, changes color or shape, or
appears abnormal in any other way.
Do not replace the battery pack when the device is turned
on.
Do not remove or damage the battery pack’s label.
Do not use the battery pack if it is damaged in any part.
Battery pack usage by children should be supervised.
As with other types of batteries, Lithium-Ion (LI) batteries will
lose capacity over time. Capacity deterioration is noticeable after
one year of service whether the battery is in use or not. It is difficult to precisely predict the finite life of a LI battery, but cell manufacturers rate them at 500 charge cycles. In other words, the
batteries should be expected to take 500 full discharge / charge cycles before needing replacement. This number is higher if partial
discharging / recharging is adhered to rather than full / deep discharging.
Storage of batteries for long time at fully charged status or
at fully discharged status should be avoided.
CAUTION
Quick Reference Guide
13
Charging the Batteries
Only in case of long storage, to avoid deep discharge of the
battery it is recommended to partially recharge the battery every three months to keep the charge status at a
medium level.
CAUTION As a reference, run a fast recharge for 20 minutes every
three months on unused products to avoid any performance deterioration of the cell.
The useful life of LI batteries depends on usage and number of
charges, etc., after which they should be removed from service, especially in mission critical applications. Do not continue to use a
battery showing excessive loss of capacity, it should be properly recycled / disposed of and replaced.
Collect and recycle waste batteries separately from the device in
comply with European Directive 2006/66/EC, 2011/65/EU,
2002/96/EC and 2012/19/EU, and subsequent modifications,
US and China regulatory and others laws and regulations about
the environment.
14
Gryphon™ I GM410X
Charging the Batteries
Replacing the Batteries
Before proceeding, read “Battery Safety” on the
preceding pages. Datalogic recommends annual
replacement of rechargeable battery packs to
ensure maximum performance.
Use the following procedure to change the reader’s battery:
1.
With a screwdriver, unscrew the battery cover screw.
2.
Unplug the three screws securing the battery holder, and
unplug the white connector.
Screw
Connector
Screw
Quick Reference Guide
Screw
15
Charging the Batteries
3.
Carefully lift out the gold contacts circuit, and remove
the battery holder while letting the white connector pass
through the hole in the battery holder (as shown below).
Pass-through
hole
Gold
contacts
circuit
4.
Remove the old battery from its place (if present), and
insert the new battery in the same position.
5.
Replace the battery holder, plug in the connector and
return the contacts circuit to its previous location.
When inserting the new battery into the handle, take care
to position the battery and the connector as shown.
6.
16
Insert the cover in the handle and screw it back into
place.
Gryphon™ I GM410X
Linking the Reader to a Base Station
Linking the Reader to a Base Station
RF Devices
For RF devices, before configuring the interface it is necessary to
link the handheld with the base.
To link the handheld and the base, press the trigger to wake it and
place it on the base. If the reader was previously linked to another
base, you must first scan the Unlink action command before relinking to the new base.
Unlink
System and Network Layouts
Stand Alone Layouts
Figure 8. Single Reader Layout
Quick Reference Guide
17
System and Network Layouts
Figure 9. Multiple Reader Layout
In stand alone systems, each cradle is connected to a single Host.
Figure 10. Multiple Stand Alone Layouts
Many stand alone connections can operate in the same physical
area without interference, provided all readers and cradles in the
system have different addresses.
18
Gryphon™ I GM410X
Select the Interface Type
Select the Interface Type
Upon completing the physical connection between the reader and
its host, proceed directly to Interface Selection on page 19 for information and programming for the interface type the reader is
connected to (for example: RS-232, Keyboard Wedge, USB, etc.)
and scan the appropriate barcode to select your system’s correct
interface type.
Interface Selection
Each reader model will support one of the following sets of host
interfaces:
General Purpose Models: RS-232, RS-232 OPOS, USB, Key-
board Wedge
Retail Point of Sale Models : RS-232, RS-232 OPOS, USB, IBM
46XX
Configuring the Interface
Scan the programming barcode which selects the appropriate interface type matching the system the reader will be connected to.
Next, proceed to the corresponding chapter in the Gryphon™ I
GD4100/GM410X PRG to customize any settings and features
associated with that interface.
Unlike some other programming features and options,
interface selections require that you scan only one
programming barcode label. DO NOT scan an ENTER/
EXIT barcode prior to scanning an interface selection
barcode.
Some interfaces require the scanner to start in the disabled state when powered up. If additional scanner
configuration is desired while in this state, pull the
trigger and hold for 5 seconds. The scanner will change
to a state that allows programming with barcodes.
Quick Reference Guide
19
Select the Interface Type
RS-232
RS-232 standard interface
Select RS232-STD
RS-232 Wincor-Nixdorf
Select RS232-WN
RS-232 for use with OPOS/UPOS/JavaPOS
Select RS-232 OPOS
USB Com to simulate RS-232 standard interface
Select USB-COM-STDa
IBM
IBM-46xx Port 5B reader interface
Select IBM-P5B
20
Gryphon™ I GM410X
Select the Interface Type
IBM (continued)
IBM-46xx Port 9B reader interface
Select IBM-P9B
USB-OEM
USB-OEM
(can be used for OPOS/UPOS/JavaPOS)
Select USB-OEM
a. Download the correct USB Com driver from www.datalogic.com
KEYBOARD
AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/
Standard Key Encoding
Select KBD-AT
Keyboard Wedge for IBM AT PS2 with standard key encoding but without external
keyboard
Select KBD-AT-NK
AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95
w/Alternate Key
Select KBD-AT-ALT
Quick Reference Guide
21
Select the Interface Type
KEYBOARD (continued)
Keyboard Wedge for IBM AT PS2 with alternate key encoding but without external keyboard
Select KBD-AT-ALT-NK
PC/XT w/Standard Key Encoding
Select KBD-XT
Keyboard Wedge for IBM Terminal 3153
Select KBD-IBM-3153
Keyboard Wedge for IBM Terminals 31xx, 32xx, 34xx, 37xx make only keyboard
Select KBD-IBM-M
Keyboard Wedge for IBM Terminals 31xx, 32xx, 34xx, 37xx make break keyboard
Select KBD-IBM-MB
Keyboard Wedge for DIGITAL Terminals
VT2xx, VT3xx, VT4xx
Select KBD-DIG-VT
22
Gryphon™ I GM410X
Select the Interface Type
KEYBOARD (continued)
USB Keyboard with standard key encoding
Select USB Keyboard
USB Keyboard with alternate key encoding
Select USB Alternate Keyboard
USB Keyboard for Apple computers
Select USB-KBD-APPLE
WAND EMULATION
Wand Emulation
Select WAND
Quick Reference Guide
23
Keyboard Interface
Keyboard Interface
Use the programming barcodes to select options for USB Keyboard and Wedge Interfaces.
Standard Factory Settings
Reference the Gryphon™ I GD4100/GM410X Product Reference Guide (PRG) for a listing of standard factory settings.
Scancode Tables
Reference the Gryphon™ I GD4100/GM410X PRG for information about control character emulation which applies to
keyboard interfaces.
Country Mode
This feature specifies the country/language supported by the
keyboard. Only the following interfaces support ALL Country
Modes.
•
USB Keyboard (without alternate key encoding)
•
AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 &
95 w/Std Key Encoding
•
Keyboard Wedge for IBM AT PS2 with standard key
encoding but without external keyboard
•
AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 &
95 without Alternate Key
•
Keyboard Wedge for IBM AT PS2 without alternate
key encoding but without external keyboard
All other interfaces support ONLY the following Country
Modes: U.S., Belgium, Britain, France, Germany, Italy, Spain,
Sweden.
24
Gryphon™ I GM410X
Country Mode
COUNTRY MODE
ENTER/EXIT PROGRAMMING MODE
Country Mode = U.S.
Country Mode = Belgium
Country Mode = Britain
Country Mode = Croatia*
Country Mode = Czech Republic*
*Supports only the interfaces listed in the Country Mode feature
description
Quick Reference Guide
25
Country Mode
COUNTRY MODE (continued)
Country Mode = Denmark*
Country Mode = France
Country Mode = French Canadian
Country Mode = Germany
Country Mode = Hungary*
*Supports only the interfaces listed in the Country Mode feature
description
26
Gryphon™ I GM410X
Country Mode
COUNTRY MODE (continued)
Country Mode = Italy
Country Mode = Japanese 106-key*
Country Mode = Lithuanian
Country Mode = Norway*
Country Mode = Poland*
Country Mode = Portugal*
*Supports only the interfaces listed in the Country Mode feature
description
Quick Reference Guide
27
Country Mode
COUNTRY MODE (continued)
Country Mode = Romania*
Country Mode = Slovakia*
Country Mode = Spain
Country Mode = Sweden
Country Mode = Switzerland*
*Supports only the interfaces listed in the Country Mode feature
description
28
Gryphon™ I GM410X
Caps Lock State
Caps Lock State
This option specifies the format in which the reader sends character data. This applies to keyboard wedge interfaces. This does not
apply when an alternate key encoding keyboard is selected.
ENTER/EXIT PROGRAMMING MODE
Caps Lock State = Caps Lock OFF
Caps Lock State = Caps Lock ON
Caps Lock State = AUTO Caps Lock Enable
Quick Reference Guide
29
Numlock
Numlock
This option specifies the setting of the Numbers Lock (Numlock)
key while in keyboard wedge interface. This only applies to alternate key encoding interfaces. It does not apply to USB keyboard.
ENTER/EXIT PROGRAMMING MODE
Numlock = Numlock key unchanged
Numlock = Numlock key toggled
30
Gryphon™ I GM410X
Programming
Programming
The reader is factory-configured with a set of standard default features. After scanning the interface barcode from the Interfaces section, you can select other options and customize your reader
through use of the instructions and programming barcodes available in the Gryphon™ I GD4100/GM410X Product Reference
Guide (PRG). Check the corresponding features section for your
interface, and also the Data Editing and Symbologies chapters of
the PRG.
Using the Programming Barcodes
This manual contains barcodes which allow you to reconfigure
your reader. Some programming barcode labels, like the Standard
Product Default Settings on page 31, require only the scan of that
single label to enact the change.
Other barcodes require the reader to be placed in Programming
Mode prior to scanning them. Scan an ENTER/EXIT barcode
once to enter Programming Mode, scan the desired parameter settings, then scan the ENTER/EXIT barcode a second time to accept your changes, exit Programming Mode and return the reader
to normal operation.
Configure Other Settings
Additional programming barcodes are available in the Gryphon™ I GD4100/GM410X PRG to allow for customizing programming features. If your installation requires different
programming than the standard factory default settings, refer to
the PRG.
Resetting Standard Product Defaults
If you aren’t sure what programming options are in your reader,
or you’ve changed some options and want the factory settings restored, scan the Standard Product Default Settings barcode below
to copy the factory configuration for the currently active interface
to the current configuration.
Factory defaults are based on the interface type. Configure the reader for the correct interface before scanning this label.
Standard Product Default Settings
Quick Reference Guide
31
Technical Specifications
Technical Specifications
The following table contains Physical and Performance Characteristics, User Environment and Regulatory information.
Item
Description
Physical Characteristics
Color
White/Gray
Black/Gray
Dimensions
Height 7.1”/181 mm
Length 3.9”/100 mm
Width 2.8”/71 mm
Weight (without cable)
Approximately
8.7 ounces/246 g (reader with display)
8.7 ounces/246 g (base charger)
Electrical Characteristics
Battery Type
Li-Ion battery pack
4 hours with 12V external power supply adaptera
Typical charge time for full
Max 22 hours with Host power
charge from full discharge
(in this case no supply adapter is needed)a
Operating autonomy
(continuous reading)
50,000 reads
(typical)
Cradle consumption
Volt 4.75-14 VDC; Power <8Wb;
and DC input supply range Max 500mA when in host/bus powered modeb.
Performance Characteristics
Light Source
LEDs
Roll (Tilt) Tolerance
± 35° from normal
Pitch Tolerance
± 65°
Skew (Yaw) Tolerance
± 65°
Field of View
10” (25.4cm) wide at 12.5” (31.8cm) from the reader
a. Charge Times are much lower when battery is within daily typical operating
condition.
b. Typical input current measured under factory default configuration.
32
Gryphon™ I GM410X
Technical Specifications
Item
Description
Depth of Field (Typical)a
3 mil – 2.9” to 4.7” (7.5cm to 12cm)
13 mild – 1.2” to 23.6” (3cm to 60cm)
20 mil – 1.2” to 31.5” (3cm to 80cm)
Minimum Element Width
3 mil
Print Contrast Minimum
15% minimum reflectance
Decode Capability
UPC/EAN/JAN, P2 /P5 add-ons; Code 39; Italian Pharmacode 39; Code 128; C128 ISBT; Code 128 add-ons; I 2 of 5;
Standard 2 of 5; Code 11;Codabar; EAN 128; Code 93; MSI;
GS1 DataBar™ Omnidirectional, GS1 DataBar™ Limited,
GS1 DataBar™ Expanded; Code4, Code5.
Interfaces Supportedb
RS-232 Std, RS-232 Wincor-Nixdorf, RS-232 OPOS, IBM
46xx (ports5B and 9B), USB Com Std., USB Keyboard, USB
Alternate Keyboard, USB OEM, Keyboard Wedge (AT with
or w/o Alternate Key, IBM AT PS2 with or w/o Alternate
Key, PC-XT, IBM 3153, IBM Terminals 31xx, 32xx,34xx,
37xx make only and make break keyboard, Digital Terminals VT2x, VT3xx, VT4xx, and Apple) and Wand Emulation.
User Environment
Operating Temperature
32° to 122° F (0° to 50° C)
Charging Temperature
32° to 104° F (0° to 40° C)
Storage Temperature
-4° to 158° F (-20° to 70° C)
Humidity
Operating: 5% to 90% relative humidity,
non-condensing
Drop Specifications
Scanner withstands 18 drops from 1.8 meters
(5.9 feet) to concrete
Ambient Light Immunity
Up to 100,000 Lux
Contaminants Spray/rain
Dust/particulates
IEC 529-IP52 (scanner only)
ESD Level
16 KV
a. 13 mils DOF based on EAN. All others are Code 39. All labels grade A, typical
environmental light, 20°C, label inclination 10°
b. See Interface Selection on page 19 for a listing of available interface sets by
model type.
Quick Reference Guide
33
Technical Specifications
Item
Description
Regulatory
Electrical Safety
EMI/RFI
UL 60950, CSA C22.2 No. 60950, IEC 60950
910 MHz model
433 MHz model
Europe - CE, Russia – Gost; USA/Canada – FCC/IC;
Australia – Ctick;
Mexico – NOM + Cofetel
China – SRRC;
Singapore – IDA,
Anatel Brazil
LED class safety
IEC Class 1
Radio Features
Working Center Frequency
Range (in open air)
433MHz model
910MHz model
433.920 MHz
910.000 MHz
30 m
15 m
433MHz model
910MHz model
16
16
System Configuration
Max. number of devices per
base station
34
Gryphon™ I GM410X
LED and Beeper Indications
LED and Beeper Indications
The reader’s beeper sounds and its LED illuminates to indicate
various functions or errors on the reader. An optional “Green
Spot” also performs useful functions. The following tables list
these indications. One exception to the behaviors listed in the tables is that the reader’s functions are programmable, and may or
may not be turned on. For example, certain indications such as
the power-up beep can be disabled using programming barcode
labels.
INDICATION
Power-up Beep
DESCRIPTION
LED
BEEPER
Reader beeps
four times at
highest frequency and volume upon
power-up.
The reader is in
the process of
powering-up.
Good Read Beep
A label has been
successfully
scanned by the
reader.
LED behavior
for this indication is configurable via the
feature “Good
Read: When to
Indicate”
(see the PRG for
information.)
The reader will
beep once at current frequency,
volume, mono/
bi-tonal setting
and duration
upon a successful label scan.
ROM Failure
There is an error
in the reader's
software/programming
Flashes
Reader sounds
one error beep at
highest volume.
Limited Scanning Label Read
Indicates that a
host connection
is not established
when the IBM or
USB interface is
enabled.
N/A
Reader 'chirps'
six times at the
highest frequency and current volume.
Reader Active
Mode
The reader is
active and ready
to scan.
Quick Reference Guide
The LED is lit
steadilya
N/A
35
LED and Beeper Indications
INDICATION
DESCRIPTION
LED
BEEPER
Reader
Disabled
The reader has
been disabled by
the host.
The LED blinks
continuously
N/A
Green Spot is on
continuously
While in Stand
Mode or Trigger
Stand Mode the
green spot shall
be on while in
stand watch
state.
N/A
N/A
Green Spota
flashes momentarily
Upon successful
read of a label,
the software shall
turn the green
spot on for the
time specified by
the configured
value.
N/A
N/A
Programming Mode - The following indications ONLY occur when the reader is
in Programming Mode.
Label Programming Mode
Entry
A valid programming label has
been scanned.
Label Programming Mode
Rejection of
Label
A label has been
rejected.
Label Programming Mode
Acceptance of
Partial Label
In cases where
multiple labels
must be scanned
to program one
feature, this indication acknowledges each
portion as it is
successfully
scanned.
36
LED blinks continuously
Reader sounds
four low frequency beeps.
N/A
Reader sounds
three times at
lowest frequency and current volume.
N/A
Reader sounds
one short beep at
highest frequency and current volume.
Gryphon™ I GM410X
Error Codes
INDICATION
DESCRIPTION
Label Programming Mode
Acceptance of
Programming
Configuration
option(s) have
been successfully
programmed via
labels and the
reader has exited
Programming
Mode.
Label Programming Mode Cancel Item Entry
Cancel label has
been scanned.
LED
BEEPER
N/A
Reader sounds
one high frequency beep and
4 low frequency
beeps followed
by reset beeps.
N/A
Reader sounds
two times at low
frequency and
current volume.
a. Except when in sleep mode or when a Good Read LED Duration other than 00
is selected
Error Codes
Upon startup, if the reader sounds a long tone, this means the
reader has not passed its automatic Selftest and has entered FRU
(Field Replaceable Unit) isolation mode. If the reader is reset, the
sequence will be repeated. The following table describes the LED
flashes/beep codes associated with an error found.
NUMBER OF
LED
FLASHES/
BEEPS
ERROR
1
Configuration
2
Interface PCB
4
Reader Module
5
Laser Pointer (if so
equipped)
6
Digital PCB
14
CPLD/Code Mismatch
Quick Reference Guide
CORRECTIVE ACTION
Contact Helpdesk for
assistance
37
Base Station Indications
Base Station Indications
INDICATION
LEDS
Power-up Complete
Yellow LED on
Reader Disabled by the HOST or the communication with HOST is not established
Yellow LED blinking ~1Hz
Data/labels are transmitted to the HOST
Yellow LEDs turned off for
100mSec
Programming Mode
Yellow LED blinks quickly
Configuration alignment with the HH is in
progress
Red LED blinks quickly
Battery charger in progress
Red LED on
Battery charger complete
Green LED on
Battery charger error
Green LED and Red LEDs blink
alternatively ~1Hz
No HH is placed on the cradle
Red and Green LEDs off
38
Gryphon™ I GM410X
Ergonomic Recommendations
Ergonomic Recommendations
CAUTION
•
•
•
•
•
•
•
•
•
•
•
To avoid or minimize the potential risk of ergonomic injury
follow the recommendations below. Consult with your local
Health & Safety Manager to ensure that you are adhering to
your company’s safety programs to prevent employee
injury.
Reduce or eliminate repetitive motion
Maintain a natural position
Reduce or eliminate excessive force
Keep objects that are used frequently within easy reach
Perform tasks at correct heights
Reduce or eliminate vibration
Reduce or eliminate direct pressure
Provide adjustable workstations
Provide adequate clearance
Provide a suitable working environment
Improve work procedures.
Cleaning
Exterior surfaces and scan windows exposed to spills, smudges or
debris accumulation require periodic cleaning to ensure best performance during scanning operations. Contacts on the scanner
and the base should also be cleaned as needed to ensure a good
connection.
Use a soft, dry cloth to clean the product. If the product is very
soiled, clean it with a soft cloth moistened with a diluted non-aggressive cleaning solution or diluted ethyl alcohol.
Do not use abrasive or aggressive cleansing agents or abrasive pads to clean scan windows, contacts or plastics.
Do not spray or pour liquids directly onto the unit.
CAUTION
Quick Reference Guide
39
Regulatory Information
Regulatory Information
All models are designed to be compliant with rules and regulations in locations they are sold and will be labeled as required.
Any changes or modifications to equipment, not expressly approved by Datalogic could void the user's authority to operate the
equipment.
Statement of Agency Compliance
This device complies with part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC Class B Compliance Statement
The user is cautioned that changes or modifications not expressly
approved by the part responsible for compliance could void the
user’s authority to operate the equipment.
This equipment has been tested and found to comply with the
limits for a Class B digital device pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and
receiver.
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•
Consult the dealer or an experienced radio or television
technician for help.
FCC RF Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits under Specific Absorption Rate (SAR) tests for portable devices operating closer than 20 cm to nearby persons, set forth in an
uncontrolled environment. The Gryphon M4100 cordless imaging reader has been demonstrated to meet these RF emissions
safety limits.
40
Gryphon™ I GM410X
Regulatory Information
Canadian Notice
This equipment does not exceed the Class B limits for radio noise
emissions as described in the Radio Interference Regulations of
the Canadian Department of Communications.
Le present appareil numerique n’emet pas de bruits radioelectriques
depassant les limites applicables aux appareils numeriques de la classe
B prescrites dans le Reglement sur le brouillage radioelectrique edicte
par le ministere des Communications du Canada.
CAUTION
Do not attempt to open or otherwise service any components in the optics cavity. Opening or servicing any part of
the optics cavity by unauthorized personnel may violate
laser safety regulations.
Power Supply
This device is intended to be connected to a UL Listed/CSA Certified computer which supplies power directly to the reader or else
be supplied by UL Listed/CSA Certified Power Unit marked
“Class 2” or LPS power source rated 5-14V minimum 900mA,
which supplies power directly to the Base/Charger via the power
connector of the Base itself.
Características de la
fuente de alimentación
eléctrica.
Atencíon
Entrada:
100 - 240 Vca
min 400 mA 50-60 Hz
Salida:
12VDC, máx 1500mA (-)Negativo al centro
Utilice en su red solo fuentes certificadas en Argentina.
El uso de fuentes de alimentación no compatibles puede resultar en
riesgo de incendio o de choque eléctrico para el usuario.
Cofetel Mexico Update
Este Producto es usable en Mexico
Certificado Nr. RCPDASM09-1246 (COFETEL)
Certificado Nr. RCPDASM09-1247 (COFETEL)
Certificado Nr. RCPDAST11-0732 (COFETEL)
La operación de este equipo está sujeta a las siguientes dos
condiciones: (1) es posible que este equipo o dispositivo no
cause interferencia perjudicial y (2) este equipo o dispositivo
debe aceptar cualquier interferencia, incluyendo la que
pueda causar su operación no deseada.
Quick Reference Guide
41
42
X
X
‫ܝ‬ᄺ㒘ӊ
‫ܝ‬ᄺ㒘ӊ
Assy, Optics Block
Assy, Module
O
O
O
ᳮ
Mercury
(Hg)
O
O
O
叏
Hexavalent
Chromium
(Cr(VI))
Polybrominated
biphenyls
(PBB)
O
O
O
౐ચ卲
O
O
O
ᄙᄽ侶૖
᦭Ქ᦭ኂ‛凝ᚗర⚛
Cadmium
(Cd)
O
O
O
ᄙᄽԲ૖ㅘ
Polybrominated
diphenyl ethers
(PBDE)
Oઍ⴫ᱝẊㇱઙ⊛ᚲ᦭ဋ凝‫ޗ‬றխࢬܶऱ具Ẋ‫ڶ੅ڶ‬୭ढ凝݁‫܅‬Պխ䦀Գ‫ا‬٥ࡉ㧺ॾஒ䣈䢓ຝᚲ咒ؒ⊛
‫ޝ‬䶣՗ॾஒ䣈঴խ‫ڶ੅ڶ‬୭ढ凝ऱૻၦ૞‫ޣ‬ρ(SJ/T 11363-2006) 億ࡳऱૻၦ‫ޕ‬
X:ઍ⴫ᱝẊㇱઙᚲ↪⊛ဋ凝‫ޗ‬றխ, ⥋ዋ᦭৻㮕᧚ᢱ౔ᚲ฽⊛᦭Ქ᦭ኂ‛凝೏Պխ䦀Գ‫ا‬٥ࡉ㧺ॾஒ䣈䢓ຝᚲ咒ؒ⊛
‫ޝ‬䶣՗ॾஒ䣈঴խ‫ڶ੅ڶ‬୭ढ凝ऱૻၦ૞‫ޣ‬ρ(SJ/T 11363-2006) 億ࡳऱૻ㊂
X
⬉䏃ᵓ㒘ӊ
Printed Circuit Board Assembly
PART
卋
ㇱઙฬ⒓
Lead
(Pb)
Regulatory Information
China RoHS Table of Restricted Elements (Scanner)
Gryphon™ I GM410X
Quick Reference Guide
X
‫ܝ‬ᄺ㒘ӊ
Assy, Module
O
O
O
O
叏
Hexavalent
Chromium
(Cr(VI))
Polybrominated
biphenyls
(PBB)
O
O
౐ચ卲
O
O
ᄙᄽ侶૖
᦭Ქ᦭ኂ‛凝ᚗర⚛
Cadmium
(Cd)
O
O
ᄙᄽԲ૖ㅘ
Polybrominated
diphenyl ethers
(PBDE)
Oઍ⴫ᱝẊㇱઙ⊛ᚲ᦭ဋ凝‫ޗ‬றխࢬܶऱ具Ẋ‫ڶ੅ڶ‬୭ढ凝݁‫܅‬Պխ䦀Գ‫ا‬٥ࡉ㧺ॾஒ䣈䢓ຝᚲ咒ؒ⊛
‫ޝ‬䶣՗ॾஒ䣈঴խ‫ڶ੅ڶ‬୭ढ凝ऱૻၦ૞‫ޣ‬ρ(SJ/T 11363-2006) 億ࡳऱૻၦ‫ޕ‬
ઍ⴫ᱝẊㇱઙᚲ↪⊛ဋ凝‫ޗ‬றխ, ⥋ዋ᦭৻㮕᧚ᢱ౔ᚲ฽⊛᦭Ქ᦭ኂ‛凝೏Պխ䦀Գ‫ا‬٥ࡉ㧺ॾஒ䣈䢓ຝᚲ咒ؒ⊛
X:
‫ޝ‬䶣՗ॾஒ䣈঴խ‫ڶ੅ڶ‬୭ढ凝ऱૻၦ૞‫ޣ‬ρ(SJ/T 11363-2006) 億ࡳऱૻ㊂
X
ᳮ
卋
ㇱઙฬ⒓
⬉䏃ᵓ㒘ӊ
Printed Circuit Board Assembly
PART
Mercury
(Hg)
Lead
(Pb)
Regulatory Information
China RoHS Table of Restricted Elements (Base)
43
44
GM4100-BK-433
BC4010-BK-433
(01)07898916345826
0019-10-4727
“Este equipamento opera em caráter secundário,
isto é, não tem direito a proteção contra
interferência prejudicial, mesmo de estações do
mesmo tipo, e não pode causar interferência a
sistemas operando em caráter primário.”
GM4100-WH-D433
BC4030-WH-433
(01)07898916345819
(01)07898916345802
GM4100-BK-D433
BC4030-BK-433
0019-10-4727
0019-10-4727
GM4100-WH-433
BC4010-WH-433
(01)07898916345833
0019-10-4727
Regulatory Information
Anatel Statement
Gryphon™ I GM410X
Regulatory Information
WEEE Statement
Waste Electrical and Electronic Equipment
(WEEE) Statement
English
For information about the disposal of Waste Electrical and Electronic Equipment (WEEE),
please refer to the website at www.datalogic.com.
Italian
Per informazioni sullo smaltimento delle apparecchiature elettriche ed elettroniche
consultare il sito Web www.datalogic.com.
French
Pour toute information relative à l’élimination des déchets électroniques (WEEE),
veuillez consulter le site internet www.datalogic.com.
German
Informationen zur Entsorgung von Elektro- und Elektronik- Altgeräten (WEEE) erhalten
Sie auf der Webseite www.datalogic.com.
Spanish
Si desea información acerca de los procedimientos para el desecho de los residuos del
equipo eléctrico y electrónico (WEEE), visite la página Web www.datalogic.com.
Portuguese
Para informações sobre a disposição de Sucatagem de Equipamentos Elétricos e
Eletrônicos (WEEE -Waste Electrical and Electronic Equipment), consultar o site web
www.datalogic.com.
Chinese
有关处理废弃电气电子设备 (WEEE) 的信息, 请参考 Datalogic
公司的网站: http://www.datalogic.com/。
Japanese
廃電気電子機器 (WEEE) の処理についての関連事項は
Datalogic のサイト www.datalogic.com をご参照下さい。
Quick Reference Guide
45
Regulatory Information
Imager Labeling
Labels are shown here to illustrate their location only. Please view
the labels on your product for actual details.
Scanner Regulatory Label
Base Station Label
C
PATENTS PENDING
46
239045
US
Gryphon™ I GM410X
Regulatory Information
Datalogic ADC Limited Factory Warranty
Warranty Coverage
Datalogic warrants to Customer that Datalogic's products will be
free from defects in materials and workmanship for a period of 3
years from product shipment. This warranty does not extend to
batteries and cables.
Datalogic ADC (“Datalogic”) hardware products are warranted
against defects in material and workmanship under normal and
proper use. The liability of Datalogic under this warranty is limited to furnishing the labor and parts necessary to remedy any defect covered by this warranty and restore the product to its
normal operating condition. Repair or replacement of product
during the warranty does not extend the original warranty term.
Products are sold on the basis of specifications applicable at the
time of manufacture and Datalogic has no obligation to modify
or update products once sold.
If Datalogic determines that a product has defects in material or
workmanship, Datalogic shall, at its sole option repair or replace
the product without additional charge for parts and labor, or
credit or refund the defective products duly returned to Datalogic. To perform repairs, Datalogic may use new or reconditioned
parts, components, subassemblies or products that have been
tested as meeting applicable specifications for equivalent new
material and products. Customer will allow Datalogic to scrap all
parts removed from the repaired product. The warranty period
shall extend from the date of shipment from Datalogic for the
duration published by Datalogic for the product at the time of
purchase (Warranty period). Datalogic warrants repaired hardware devices against defects in workmanship and materials on
the repaired assembly for a 90 day period starting from the date
of shipment of the repaired product from Datalogic or until the
expiration of the original warranty period, whichever is longer.
Datalogic does not guarantee, and it is not responsible for, the
maintenance of, damage to, or loss of configurations, data, and
applications on the repaired units and at its sole discretion can
return the units in the “factory default” configuration or with any
software or firmware update available at the time of the repair
(other than the firmware or software installed during the manufacture of the product). Customer accepts responsibility to maintain a back up copy of its software and data.
Warranty Claims Process
In order to obtain service under the Factory Warranty, Customer
must notify Datalogic of the claimed defect before the expiration
of the applicable Warranty period and obtain from Datalogic a
return authorization number (RMA) for return of the product to a
designated Datalogic service center. If Datalogic determines
Customer’s claim is valid, Datalogic will repair or replace product
without additional charge for parts and labor. Customer shall be
responsible for packaging and shipping the product to the designated Datalogic service center, with shipping charges prepaid.
Datalogic shall pay for the return of the product to Customer if
the shipment is to a location within the country in which the Da-
Quick Reference Guide
47
Regulatory Information
talogic service center is located. Customer shall be responsible
for paying all shipping charges, duties, taxes, and any other
charges for products returned to any other locations. Failure to
follow the applicable RMA policy, may result in a processing fee.
Customer shall be responsible for return shipment expenses for
products which Datalogic, at its sole discretion, determines are
not defective or eligible for warranty repair.
Warranty Exclusions
The Datalogic Factory Warranty shall not apply to:
(i)
(ii)
(iii)
(iv)
(v)
(vi)
(vii)
(viii)
any product which has been damaged, modified,
altered, repaired or upgraded by other than Datalogic
service personnel or its authorized representatives;
any claimed defect, failure or damage which Datalogic
determines was caused by faulty operations, improper
use, abuse, misuse, wear and tear, negligence, improper
storage or use of parts or accessories not approved or
supplied by Datalogic;
any claimed defect or damage caused by the use of
product with any other instrument, equipment or apparatus;
any claimed defect or damage caused by the failure to
provide proper maintenance, including but not limited
to cleaning the upper window in accordance with product manual;
any defect or damage caused by natural or man-made
disaster such as but not limited to fire, water damage,
floods, other natural disasters, vandalism or abusive
events that would cause internal and external component damage or destruction of the whole unit, consumable items;
any damage or malfunctioning caused by non-restoring
action as for example firmware or software upgrades,
software or hardware reconfigurations etc.;
the replacement of upper window/cartridge due to
scratching, stains or other degradation and/or
any consumable or equivalent (e.g., cables, power supply, batteries, keypads, touch screen, triggers etc.).
No Assignment
Customer may not assign or otherwise transfer its rights or obligations under this warranty except to a purchaser or transferee
of product. No attempted assignment or transfer in violation of
this provision shall be valid or binding upon Datalogic.
DATALOGIC'S LIMITED WARRANTY IS IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, ORAL OR WRITTEN, STATUTORY OR OTHERWISE, INCLUDING, WITHOUT LIMITATION, ANY
IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A
PARTICULAR PURPOSE, OR NONINFRINGEMENT. DATALOGIC
SHALL NOT BE LIABLE FOR ANY DAMAGES SUSTAINED BY CUSTOMER ARISING FROM DELAYS IN THE REPLACEMENT OR REPAIR
OF PRODUCTS UNDER THE ABOVE. THE REMEDY SET FORTH IN
THIS WARRANTY STATEMENT IS THE CUSTOMER’S SOLE AND EX48
Gryphon™ I GM410X
Regulatory Information
CLUSIVE REMEDY FOR WARRANTY CLAIMS. UNDER NO CIRCUMSTANCES WILL DATALOGIC BE LIABLE TO CUSTOMER OR ANY
THIRD PARTY FOR ANY LOST PROFITS, OR ANY INCIDENTAL,
CONSEQUENTIAL IN-DIRECT, SPECIAL OR CONTINGENT DAMAGES REGARDLESS OF WHETHER DATALOGIC HAD ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.
Risk of Loss
Customer shall bear risk of loss or damage for product in transit
to Datalogic. Datalogic shall assume risk of loss or damage for
product in Datalogic’s possession. In the absence of specific written instructions for the return of product to Customer, Datalogic
will select the carrier, but Datalogic shall not thereby assume any
liability in connection with the return shipment.
Quick Reference Guide
49
Regulatory Information
NOTES
50
Gryphon™ I GM410X
DECLARATION OF CONFORMITY
EC-056
13
Datalogic ADC Srl, Via S. Vitalino, 13
Lippo di Calderara di Reno (BO) 40012 Italy
Rev.: 4
Pag.: 1 di 1
La presente dichiarazione di conformità è rilasciata sotto la responsabilità esclusiva di Datalogic
ADC Srl per:
This Declaration of Conformity is issued under the sole responsibility of Datalogic ADC Srl for:
Cette déclaration de conformité est établie sous la seule responsabilité de Datalogic Srl pour:
Diese Konformitätserklärung wird unter der alleinigen Verantwortung des Datalogic ADC Srl
erteilt für:
Esta declaración de conformidad se expide bajo la exclusiva responsabilidad de Datalogic ADC Srl
para:
Gryphon GM 41xx ; Cordless Barcode Reader
Gryphon BC 40xx ; Cordless Base Station /Charger
e tutti i suoi modelli
and all its models
et tous ses modèles
und seine Modelle
y todos sus modelos
sono conformi alle Direttive del Consiglio Europeo sottoelencate:
are in conformity with the requirements of the European Council Directives listed below:
sont conformes aux spécifications des Directives de l'Union Européenne ci-dessous:
den nachstehenden angeführten Direktiven des Europäischen Rats:
cumple con los requisitos de las Directivas del Consejo Europeo, según la lista siguiente:
1999/5/EC - R&TTE Directive
2011/65/EU - RoHS Directive
Questa dichiarazione è basata sulla conformità dei prodotti alle norme seguenti:
This declaration is based upon compliance of the products to the following standards:
Cette déclaration repose sur la conformité des produits aux normes suivantes:
Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht:
Esta declaración se basa en el cumplimiento de los productos con las siguientes normas:
ETSI EN 301 489-3 V1.4.1, ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); ELECTROMAGNETIC COMPATIBILITY (EMC) STANDARD
AUGUST 2002 :
FOR RADIO EQUIPMENT AND SERVICES; PART 3: SPECIFIC CONDITIONS FOR SHORT-RANGE DEVICES (SRD) OPERATING ON FREQUENCIES BETWEEN 9KHZ AND 40GHZ
EN 301 489-1 V1.8.1,
APRIL 2008
ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); ELECTROMAGNETIC COMPATIBILITY (EMC) STANDARD
FOR RADIO EQUIPMENT AND SERVICES; PART 1: COMMON TECHNICAL REQUIREMENTS
ETSI EN 300 220-2 V2.1.2, ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); SHORT RANGE DEVICES (SRD); RADIO EQUIPMENT
JUNE 2007 :
TO BE USED IN THE 25MHZ TO 1000MHZ FREQUENCY RANGE
WITH POWER LEVELS RANGING UP TO 500MW; PART 2: HARMONIZED EN COVERING ESSENTIAL REQUIREMENTS UNDER ARTICLE
3.2 OF THE R&TTE DIRECTIVE
EN 60950-1, APRIL 2006 + INFORMATION TECHNOLOGY EQUIPMENT - SAFETY A11:2009 + A1:2010 +
PART 1 : GENERAL REQUIREMENTS
A12:2011 :
EN 50581, SEPTEMBER 2012:TECHNICAL DOCUMENTATION FOR THE ASSESSMENT OF ELECTRICAL AND ELECTRONIC PRODUCTS WITH RESPECT TO THE RESTRICTION OF HAZARDOUS SUBSTANCES
Lippo di Calderara, March29th ,
2013
RUGGERO CACIOPPO
QUALITY & RELIABILITY MANAGER - EUROPE
www.datalogic.com
©2009-2014 Datalogic ADC, Inc. • All rights reserved.
Datalogic and the Datalogic logo are registered trademarks of
Datalogic S.p.A. in many countries, including the U.S.A. and the E.U.
Datalogic ADC, Inc.
959 Terry Street | Eugene |OR 97402 | USA
Telephone: (1) 541-683-5700 | Fax: (1) 541-345-7140
820051314
(Rev L)
February 2014
Download PDF
Similar pages