ra730 chr chr - Cass Brothers

RADII
SINK MIXER
PRODUCT CODE:
FINISH:
STYLISH
PREMIUM
CHROME
FINISH
MATCH WITH....
RA730 CHR
CHROME
CONTEMPORARY
DESIGN
PHOENIX
WARRANTY
TECHNICAL SPECIFICATIONS
CONSUMER INFORMATION
208
30
190
RANGE:
RADII
PRODUCT:
SINK MIXER
PRODUCT CODE:
RA730 CHR
WATERMARK LICENCE:
WM21009
REVISION DATE:
DEC 2013
CONNECTION TYPE:
N/A
MATERIAL:
BRASS
AVAILABLE FINISHES:
CHROME
WELS RATING:
5 STARS
FLOW RATE:
6 LITRES PER MINUTE
TEMPERATURE RATING:
MIN 1° - MAX 75°
PRESSURE RATING:
WARRANTY:
267
55
MIN 150 KPA
- MAX 500 KPA
15 YEAR REPLACEMENT
CARTRIDGE
7 YEAR REPLACEMENT
PRODUCT OR PARTS
1YEAR REPLACEMENT PARTS
OR PRODUCT & LABOUR
143
MERCHANT INFORMATION
64
CARTON SIZE:
37
50
CARTON WEIGHT:
2.4 KG
OUTER BOX SIZE:
L 330MM x W 290MM
x H 370MM
OUTER BOX WEIGHT:
12 KG
OUTER BOX QUANTITY:
5 CARTONS
BARCODE NUMBER:
9320594 019 105
EXPLODED VIEW
PARTS LIST
1. MIXER BODY
2. SINK MIXER SPOUT
3. 25MM CARTRIDGE
4. MIXER HANDLE
5. FLEXIBLE HOSE
6. M8 NUT
7. M8 THREADED ROD
8. MOUNTING PLATE
9. MOUNTING GASKET
10. AERATOR
11. RETAINER
12. SCREW CAP
13. MIXER LOCKNUT
14. MIXER DOME
15. DRESS PLATE
16. SCREW M3X10
17. GRUB SCREW M4X5
18. GRUB SCREW M4X6
19. O-RING
20. O-RING
21. O-RING
22. SPOUT BEARING
23. SPOUT BEARING
24. NYLON RING
25. O-RING
26. O-RING
INSTALLATION INSTRUCTIONS
RADII SINK MIXER
Sidelever Sink Mixer Installation Instructions
www.phoenixtapware.com.au
75
150 KPa Min.
550 KPa Max.
Recommended Working
Pressure
Maximum hot water
temperature
Note:
-If the pressure exceeds or is likely to
exceed 550kpa, an approved pressure
limiting device must be installed.
- Flush out all pipe work prior to installation.
- If the water temperature exceeds 75°C, an
approved tempering valve must be fitted.
- Installation should comply with Australian
standard AS3500.1 or relevant local
authority requirements.
Failure to comply with the above may void
all warranties.
Installation Instruction
1 : Cut a mounting hole 35mm in diameter.
2 : Remove one of the hose assemblies from
the mixer. Run Dress Plate over both Hose
Assembly, as shown.
3 : Reattach the hose assembly to Mixer and
fasten with a spanner.
4 : Screw the threaded stud into mixer base.
5 : Fit the rubber ring into Dress Plate groove.
6 : Position Mixer over the mounting hole.
Feed the hoses through the mounting hole.
7 : From underneath the bench, fit “C” gasket
and “C” washer over both hoses and the
threaded stud .
8 : Screw on long nut and fasten firmly with a
tube spanner to secure the mixer.
9 : Connect the water supply.
Red-Marking Hose to hot water.
Blue-Marking Hose to cold water.
10:Turn on the water supply and check for
leaks.
Mixer
30mm MAX.
WATER SUPPLY REQUIREMENTS
Maintenance and Care
-Chrome plated surfaces should be cleaned
with mild liquid detergent or soap and
water.
-Do not use cream cleaners or citrus based
cleaning products, as they are abrasive.
-Use of unsuitable cleaning agents may
damage the surface. Any damage caused in
this way will not be covered by warranty.
Dress Plate
Rubber Ring
“ C ” Gasket
“ C ” Washer
HOT Water Inlet
Red-Marking Hose
Cold Water Inlet
Blue-Marking Hose
Long Nut
Threaded Stud
IN0159 revA
WARRANTY INFORMATION
MANUFACTURER’S WARRANTY
“Our goods come with a guarantee that cannot be
excluded under the Australian Consumer Law
(“ACL”), You are entitled to a replacement or refund
for a major failure and for compensation for any
reasonable or foreseeable loss or damage. You are
also entitled to have repaired or replaced if the
goods fail to be of acceptable quality and a failure
does not amount to a major failure”.
In addition to the above obligations Phoenix offers
the following Manufacturer’s Warranty subject to
the following terms and conditions. Any provision in
the warranty which is inconsistent with the ACL or is
otherwise unenforceable shall be severed from this
warranty to the extent of the inconsistency and the
remainder of the provisions shall continue to apply.
WARRANTY PERIODS
Residential
Phoenix tapware and accessories is made to the
highest industry standards and quality. Refer to
table below for warranty periods.
Catagory
Warranty
Period
Mixers
15Years
-15 Years replacement cartridge
-7Years replacement product or parts
Note: Excludes damage to ceramic
disc cartridges from pieces of copper
tube, plastic tube, sand, dirt or thread
tape etc.
-1 Year replacement product or parts
& labour.
Hand
Shower on
Rail
3Years
-3Years replacement product or parts
-1 Year replacement product or parts
and labour
Tapware &
Standard
Showers
7Years
-7Years replacement product or parts
-1Year replacement product or parts
and labour.
Note: Jumper valves and ceramic disc
spindles; 1Year parts only.
-7Years replacement product or parts
Accessories 7Years
Warranty
Details
* Note: These warranty periods apply to
products purchased after 10th April 2011.
Commercial
(Hotels, Aged Care Facilities, Hospitals, Schools,
Factories, Motels, etc.)
Catagory
All Products
Warranty
Period
1 Year
Warranty
Details
-1Year replacement product or parts
For all Service Enquiries contact below:
This Manufacturer’s Warranty is provided by Phoenix
Industries Pty Ltd.
Telephone: +61 3 9780 4200
Facsimile: + 61 3 9764 1898
Email: sales@phoenixtapware.com.au
Subject always to any overriding obligation pursuant
to the ACL, warranty shall be void for the following
reasons:
- Inability to provide proof of purchase or equivalent
documentation.
- Products not installed by a licensed plumber.
- Products not to relevant National Standards and
State Regulations.
- Products not installed in accordance with the
manufacturer’s installation instructions.
- Products exposed to environmental elements.
- Tapware exposed to water pressures and or
temperatures that exceed stated limitations.
MAXIMUM: Temperature- 75 degrees & Pressure550kPa
MINIMUM: Temperature- 1 degree & Pressure 150kPa (300kPa for Shower/Bath Diverters)
Note: AS/NSZ 3500.1-2003 (Clause 3.3.4) specifies
550kPa maximum water supply pressure at any
outlet within a building for new installations.
- Showers may not be suitable for use within:
* Gravity-fed water systems.
* Some instantaneous hot water systems.
* Pressure supply less than 150kPa.
Note: The 550kPa maximum water supply pressure
does not apply to fire service outlets.
- Isolation stop taps are not fitted as stated on
manufacturer’s installation instructions.
- Fitting of other devices to the outlet of tapware, eg.
water filters.
- Fitting of Phoenix non-approved water flow
regulating devices.
- Fitting of other devices to outlet of tap, e.g., water
filters.
- Non-installation of flow regulated check valve for
hand showers.
- Products used for incorrect applications, non
potable water etc.
- Damage as a result of obstructions due to
inadequate flushing of system before use.
- Services repairs or with non-standard replacement
parts previously undertaken without Phoenix’s
written approval.
- Damage to finishes by adhesives, sealants etc.
- Failure to clean & replace outlet aerator inserts etc.
- Damage to finishes which arise from installation or
post installation use.
- Failure to observe manufacturers care and cleaning
instructions.
- The warranty work is limited to the pre-approved
scope of work. Additional work will require author
zation from Phoenix After Sales & Services
Departments.
- Evidence cannot be produced which confirms that
the relevant product was purchased from a
Phoenix Tapware authorized distributor.
WARRANTY CONDITIONS
Phoenix Warranty covers the repair or, at Phoenix’s
option, the replacement of any products which are
defective through faulty workmanship or materials.
The warranty period commences from date of
purchase or for new buildings date of handover to a
maximum period of 6 months. The warranty period
for replacement products is limited to the expiry
date of the original purchase. The warranty is limited
to the original purchaser and non-transferable. In
order to make a warranty claim, Proof of Purchase
(POP), handover documentation for new homes or
equivalent documentation must be supplied for
warranty claims to be considered. Claims must be
processed through Phoenix’s Customer Service and
each credit claim will be issued with a claim number
which is recorded on the Phoenix system.
Phoenix will not be liable for any claims for labour,
additional products or parts associated with alleged
faulty product for work not approved in advance by
Phoenix in writing.
WARRANTY INFORMATION
WARRANTY CONDITIONS CONT.
Should any warranty claim be made and attended to
by a Phoenix authorized Service Agent and that in the
opinion of the Service Agent or Phoenix the problem
was from faulty installation or use of the goods in
conjunction with products of another manufacturer
or from some other cause other than a manufacturing
defect to the goods for which Phoenix is responsible,
Phoenix has the right to charge a service fee for each
service staff attending the Owner’s premise where
goods have been installed.
Phoenix requires adequate access to products, fittings
and fixtures to undertake warranty repairs. Phoenix
will not be responsible for any consequential damage
or costs where adequate access to product fittings
and fixtures is not accessible.
TAPWARE AND ACCESSORIES
Care and cleaning Instructions
- Under no circumstances should you install
tapware using acetone silicones.
- Never use harsh detergents, citrus based
cleaners or abrasive cleaners, as these will
scratch the surface.
- Where your tapware remains dry in use, a soft
cloth can be used to remove surface dust.
Alternatively, a wipe over with warm soapy
water is all that is required to maintain the
finish in perfect condition for a lifetime of use.
- Use of wax based furniture cream should be
avoided as these can result in a build-up of
deposits, which could detract from the
appearance.
- Do not use undue pressure and wipe in one
direction only.
Note: Phoenix reserves the right to alter, or amend
this warranty offer in writing at any time. Phoenix
reserves the right to provide minor components (eg.
handles, aerators, buttons, dress rings, hinges, clips,
rod and washers) as ‘Parts Only’ to the customer.
Download PDF
Similar pages