Head-Office - One Earth Outlet

Head-Office
2 Mercier street, Coburg Victoria 3058 Australia
Free
174 424
424
Free Call
Call 1800
1800 174
www.envirosource.com.au
AIR-WATER HOT & COLD UV/UF SYSTEM
Safety Notes
Table of Contents
Follow normal safety precautions for the air-water
filtration system.
Check the electric power supply(230V 50Hz depending on the country).
The required voltage can be found on the back of the purifier.
Overview of System
3
Principles of Computerized Digital Controller
5
System Specifications
6
Principles of Operation & Function of Parts
7
Functions of computerized & Digital controller
Avoid exposure to extreme temperatures and rain.
Installation & Operation
Place the purifier on a hard, flat surface to prevent noise and vibration.
Place the purifier more than 30 cm away from the wall for proper air flow and
operation of the condenser.
Do not decline the purifier more than 45 degrees when moving it. Handle
with care when moving and installing.
9
Location of installation
Precautions for installation
Procedure for operation
Storage
Maintenance
11
Cleaning
Connect the electric power 30 minutes after installation.
Interior
Draining the purifier
Plug into the proper outlet.
Please turn on the hot water switch after water is filled in hot water tank.
The efficiency of the machine gets lower under 18
operate the machine on 0 or below.
and user must not
Filter Exchange
Troubleshooting
13
Cold water-related problems
Hot water-related problems
Refrigeration system-related problems
Water leakage-related problems
Air water generating related problems
1
Dual & Alternative Usage
16
Reminders
17
2
AIR-WATER HOT & COLD UV/UF SYSTEM
Overview of System
Exterior
Interior
Digital
Operational
Indicator
Cold Water
Faucet
Hot Water
Faucet
Drip Tray
Humidity Sensor
Hot Water Switch
Float Cable
Water Supply Tube
Power Cord
Air suction
hole
Air filter
(inside)
Water Generator
Switch
Power Cord
Tap Water
Connection
∙Before using, connect float cable of water generator to water purifier.
3
4
AIR-WATER HOT & COLD UV/UF SYSTEM
Principles of Computerized Controller
Digital Operational indicator
System Specifications
Specifications
WAW-4012
Product size
Tank capacity
WATER PURIFIER
WATER GENERATOR
340(W) 430(D) 515(H)mm
340(W) 430(D) 575(H)mm
HOT : 1 , COLD : 4
Power
consumption
HOT : 250W, COLD : 100W
500W
Compressor
CD 130H-L1Z2, R-134a
FMA70Q2Y, R-22
Weight
24Kg
27Kg
Water generating
volume
�
Filter exchange indication
It shows exchange term of each filter
(1 : Sediment filter, 2 : Pi( -water filter,
3 : UF filter, 4 : Postcarbon filter)
Green color : Normal filter
Orange color : Filter exchange soon
Red color : Filter exchange right away
�
UV filter operation indication
During normal operation of UV filter
(UV lamp), it shows green light.
Indication will blink in case of exchange
term.
5
�
Digital humidity indication
It shows the current humidity level.
�
8
26.7 (80F), 60%, 18.9 / DAY
NOTE
Dimensions and specifications of this product are subject to change without prior
notice to the customer to enhance the product quality.
Cold water indication
It shows the operation of cold water.
� Hot water indication
It shows the operation of hot water.
Filter specifications & Exchange
Filter name
Term
1st Step
Sediment
2st Step
Pi( )-water
3st Step
U.F.
4st Step
Post-carbon
5st Step
U.V.
6 month
6 month
18 month
12 month
24 month
6
AIR-WATER HOT & COLD UV/UF SYSTEM
Principles of Operation & Function of Parts
Water flow diagram
Step 1 : Air-Filters
The first filter that air passes through before being condensed and
converted to water. Our air-filter effectively prevents micro particles
and dust from entering the machine.
Step 2 : Sediment Filter
Removes any remnants of foreign particles in the water.
Step 3 : Pi( )-Water Filter
Removes extant odor and improves taste.
Step 4 : U.F Filter
Ultra Filtration Cartridge is simply a bundle of permanently
hydrophilic (water loving) capillary membrane filters. These filters
have a highly porous, asymmetric structure in which the feed water
follows a path from the large pores on the outside wall to the small
pores on the inside wall. Ultra Filter’s patented low pressure
membrane technology is unique for its high flow rates at minimal
pressure requirements and its very tight pore size control (0.01
micron). This results in unparalleled removal of organic
contaminants, bacteria, and cysts.
The unit is fitted with a microcomputer, which ensures proper working
of internal parts to regulate, supervise, and control the functions of
individual parts inside the unit.
Step 5 : Post-Carbon Filter
Removes chlorine, bad taste, odor, sediment extant,
and THM’s sediment. Focuses on removing lead, copper,
chloroform, chemical residuals, herbicides, pesticides,
and other volatile organic compounds.
Step 6 : Ultra Violet Filter
The water collected from the air passes through a germicidal ultra
violet system. Harmful substances in the water are killed by treating
the water through this double-pass ultra violet which allows the
water to a pass through and be treated using strong ultraviolet rays.
7
8
AIR-WATER HOT & COLD UV/UF SYSTEM
Installation & Operation
Location of installation
Procedure for operation
1. Avoid direct sunlight, exposure to rain and extreme temperatures (indoor
use only).
2. Place the purifier on a hard, flat surface.
It should not be shaken or rocked.
3. Locate the purifier in a well-ventilated place.
Install it more than 30cm away from the wall to insure proper operation
and air flow.
4. Avoid harmful gas or heat.
In order to be sanitary, the purifier must not come in contact with any
harmful gas or excessive heat.
1. Add water after confirming that the cold water baffle located in the cold
water container is secure.
If the cold water baffle moves, cold water will not be formed
and discharged.
Use only water.
2. Open the hot water faucet after filling with water.
Keep open until the air held in hot water container is exhausted
and water comes out.
Power supplied when the hot water container is empty can cause
trouble.
3. Select cold water/hot water
-The purifier is configured only for cold water at the time of shipment.
If you want to use cold water only:A cold water switch is not necessary.
Cold water comes out upon connecting the power cord.
If you want both cold water and hot water:Turn the hot water switch
to the “ON” position.
CAUTION:
In subzero temperatures, the water containers may freeze and rupture.
Precautions for installation
1. Confirm the proper voltage.
Make sure to use an individual outlet.
2. When the plug becomes disconnected or power is off.
Give the purifier up to five minutes with the plug in before switching on.
3. Grounding.
If a grounding terminal is absent from the outlet, connect a single-core
cord (a Flexible copper wire of over 1.6mm in diameter) to the grounding
terminal located on the back of the purifier, and to a copperplate (over
0.7mm it thickness and 990cm in area). Bury this into the ground as
deep as 75cm.
Installation Order
●Connect power plugs of water purifier part
and water generator part into receptacles.
●Connect ①water supply of water purifier
part with ①water supply of water generator
part.
●Connect ②circulation of water purifier part
with ②circulation of water generator part.
●It is not necessary to connect "tap
connection".
CAUTION:
Never connect the grounding wire on gas pipe.
Storage
1. In case of storing the purifier for a long period of time, open the drain cap
located at the rear and completely drain all water inside the purifier.
2. Clean the purifier with care.
3. Cover to prevent dust from forming on the purifier and store the purifier
in the original box if possible.
9
10
AIR-WATER HOT & COLD UV/UF SYSTEM
Maintenance
Cleaning
Filter Exchange
Unplug the power cord and unscrew the top lid and back cover of the
purifier.
1. Sediment Filter, Pre-carbon Filter, UF Filter,
and Post Carbon Block Filter
Open the top lid with screw.
Pull out the whole filter package.
With the included tool, push the inner ring on the filling and unplug
the fitting from the filter.
Replace filters and connect the fitting again completely.
CAUTION : Electric Shock
Interior
Water drop plate
Take out the plate then clean
with neutral detergent using
soft cloth.
1. Open the top lid after loosen
back screws.
Exterior
Clean with neutral
detergent using
soft cloth.
2. Pull out the lid of reservoir
tank.
3. Clean inside with soft cloth
or sponge.
Radiator
Clean with vacuum
cleaner.
4. Before drinking, please let
water flow out.
Draining the purifier
Hot Water
11
2. Ultra Violet Filter
Unplug power cable.
Open the front panel.
Open the cap of the UV Filter.
Remove old UV Filter and replace with a new filter.
3. Air Filter
Hold the handle. Pull it to the left side and disassemble.
After user replaces new filter, insert it back again.
Wash air-filter one time by every 2 weeks.
After you dry it, user can use it again
user needs to exchange old filter with
new one by every 3~4 months.
4. How to reset after filter exchange
Cold Water
Exchange term of water purifying filter &UV Lamp:1year (12 months)
Display of water purifying filter exchange:
lighting of filter graphic “WF”Lamp.
Display of UV Lamp(sterilization Lamp) exchange:
lighting of “UV”Lamp(Red).
Resetting after exchange:pushing water purifying filter & UV Lamp
reset button more than 5 sec.
Cleaning term of air filter : 2 weeks (14 days)
Display of air filter cleaning term : lighting of air filter Lamp(Green)
Reset after air filter cleaning : Pushing air filter reset button for 1 sec.
Air filter exchange term : 3 months to 4 months.
Display of air filter exchange term : lighting of air filter Lamp(Red)
Reset of air filter exchange : pushing air filter reset button
more than 5 sec.
12
AIR-WATER HOT & COLD UV/UF SYSTEM
Troubleshooting
Cold water-related problems
Problems
Compressor
dose not
Not being
work
cooled
at all
Problems
Compressor
is working
Difficulty of cooling
water
Point to be checked
Action to be taken
Is there a power failure?
Check other electric purifiers.
Is it plugged in?
Plug in and check whether power is on.
Are all the connections OK?
Arrange the connection properly.
Refer to the circuit diagram.
Are there any damaged parts?
Replace damaged parts.
After operating for more than 30
minutes, check whether the water is
cold or not.
Repair the refrigerating system.
(Refrigerant leaks, defective compression
of compressor)
Using too much mineral water?
Use proper volume of water.
Is the purifier under direct sunlight, or
nearby heat sources such as a stove,
gas oven, etc.
Block direct sunlight or keep away
from heat sources.
Is the thermostat positioned “HIGH”
Set the thermostat position between
“Medium” and “LOW”
Is the thermostat working properly?
Replace the thermostat.
Is it installed on a flat and firm surface?
Level the purifier.
Are there any loose screws?
Tighten loose screws.
Are there any frozen pipes or surrounding
plates causing it to shake?
Leave some space between pipes.
Is the compressor well balanced?
Adjust the level of the compressor.
Is the rear of the purifier touching the
wall?
Give some space between rear of
purifier and the wall.
Are there any foreign objects around the
compressor?
Remove the foreign object.
Are there any noises coming from the
compressor valves?
Replace defective compressor.
Water is too cold
Strange noise occurs
Hot water-related problems
It is possible for the condensation to occur on the outside of product when it is installed at
the place of high humidity or when there is high humidity during the rainy season or rainy
days.
Note
This is the same phenomenon as there are condensation on the outside of water-filled
glass, so it is common to have condensation when humidity is extremely high (over 90%).
Problems
No hot water
Hot water temperature
is too low
Too high
Action to be taken
Point to be checked
Using tester, check whether hot
water switches energized.
Replace the hot water switch.
Using tester, check the hot water
thermostat(Automatic BI-METAL)
is positioned at “ON” status.
Replace Automatic BI-METAL.
Using tester,check if overheating
protector (Empty BI-METAL) is “ON”.
Push “RESET” button of manual BI-METAL.
(CAUTION: ELECTRIC SHOCK)
Check if the heater has a short-circuit.
Replace the assembly of hot water container.
Check the working conditions of
thermostat (Automatic BI-METAL)
Replace the thermostat(Automatic BIMETAL)if the temperature does not group
after checking the water temperature.
(Allow water to run for about 30min.
for stable temperature.)
Check the working conditions of
thermostat(Automatic BI-METAL):
“OFF” function does not work.
Refrigeration system-related problems
Problems
Refrigerant leakage
Clogged up with
moisture & dirt
Point to be checked
Compressor Condenser Evaporator Cooling Cond.
Discharge pipes
are slowly heated.
In the case of
refrigerant leakage,
the temperature may
rise a little, but it will
be cooled soon.
No flowing sound of
refrigerant.
A little sound at the
time of small
amounts of leakage.
Never cools.
Repair
refrigerating
system.
Contact customer
service.
Leads to high
temperature.
Temperature of
entrance is rising.
Is there any frost at drier
outlet while operating?
No flowing sound
of refrigerant.
Slowly cools.
Repair refrigerating
system.
Contact customer
service.
Same as
surrounding temp.
A little flowing
sound of
refrigerant.
Never cools.
Exchange
compressor.
Contact customer
service.
Discharge pipe has
an abnormally high
temp.
Flowing sound of
refrigerant, but
poor pooling
condition.
Frost on the suction
pipes & defective
cooling condition.
Repair refrigerating
system (recharge of
refrigerant)
Contact customer
service.
Defective discharge No difference
between the suction
& compression
& the discharge.
Over filling of
refrigerant
Action to
be taken
Sharp rise of
surface temp.
At that time, wipe the purifier with clean and dry clothes.
13
14
AIR-WATER HOT & COLD UV/UF SYSTEM
Troubleshooting
Dual & Alternative Usage
Water leakage-related problems
Problems
Leakage through
inside or outside
of purifier
Leakage through the
faucet
Dual Usage
Action to be taken
Point to be checked
Leakage in the water tank caused
by minor damages (occurs
frequently when replacing).
Replace the tank with a new tank.
Check whether the faucet is
completely connected.
Properly connect the faucet.
Check the connection of a fixed
nut in cold water container
Completely connect the fixed nut.
Check if leakages are due to a broken hot
water container or welded part.
Replace hot water container.
Check tube and tube connector.
Make sure to fasten tube into connector.
Leakage through the faucet.
Press down the faucet lever several times.
Leakage through the faucet cap and lever.
Replace the faucet.
Air water generating related problems
Problems
Air water system
does not
supply water
Point to be checked
As two unit
Use the extension cable
and tube.(Option)
Installation
Action to be taken
Is the tank dried up?
Check to see if plugged in.
Shows a low percentage of humidity?
Minimum percentage of humidity is 30%.
Is the temperature too low?
Minimum temperature is 0
Check its life span, then exchange.
Is the filter clogged?
As one unit
Huge amount of water consumption?
Wait until the water generating process
is complete.
Is the air filter dirty?
Clean air filters periodically to prevent
bad air circulation.
1. One machine type
Place a machine where you want to install.
Fix wheels in order the machine will not move or shake.
Place water purifier part on dehumidifier part.
Connect water supply hose on upper and lower part.
Connect cable on upper and lower part.
Put power plug in .
Note) Make sure that there must be at least 30cm space between the machine and
wall.
2. Dual machine type
Place water purifier part and dehumidifier part where user wants to install.
Install them in order not to be moved or shaken.
when you install dehumidifier part outside, be careful of rain.
Connect water supply hose each other.
Connect extension cable between two parts.
When user uses extension cable, do not modify on connection part.
lug in power code.
15
16
AIR-WATER HOT & COLD UV/UF SYSTEM
Reminders
Air-Water
Filtration System
Make sure the right electric power supply. (240V)
Before plug in, check the electric power supply.
Use water.
Trouble may occur if user fills with any liquid other than water.
Keep the condenser free of dirt or dust.
The cooling performance decreases when the condenser is soiled.
Disconnect the power supply during inspection.
If not disconnected, the danger of electric shock exists.
Use only soft brush or wet cloth during cleaning.
No chemicals or cleaning agents!
Make certain the UV filter is working.
Check UV indicator is working when the RUN indicator is ON.
Clean the water tanks (Top & Bottom) and air filters frequently.
Frequent cleaning is required to ensure cleanliness and proper air flow.
LIMITED WARRANTY
Envirosource warrants this product (including any accessories) against natural defects in material or
workmanship as follows :
1. LABOR: For a period of 90 days from the date of purchase, if this product is determined to be defective,
Envirosource will repair or replace the product, at its option, at no charge. After the warranty period,
you must pay for all labor charges.
2. PARTS: In addition, Envirosource will supply, at no charge, new or rebuilt replacements in exchange
for defective parts for a period of one (1) year.
This warranty does not cover cosmetic damage or damage due to acts of God, accident, misuse,
abuse,negligence, or modification of, or to any part of the Product. This warranty does not cover damage
due to improper operation or maintenance, connection to improper voltage supply, or attempted repair by
anyone other than a facility authorized by Envirosource to service the Product. This warranty does not
cover Products sold AS IS or WITH ALL FAULTS, or consumable (such as fuses or batteries). This
warranty is valid only in Australia.
Proof of purchase in the form of a bill of sale or receipted invoice which is evidence that the unit is within
the Warranty period must be presented to obtain warranty service.
REPAIR OR REPLACEMENT AS PROVIDED UNDER THIS WARRANTY IS THE EXCLUSIVE REMEDY
OF THE CONSUMER. ENVOROSOURCE SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR
CONSEQUENTIAL DAM-AGES FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTY ON THIS
PRODUCT. EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, ANY IMPLIED WARRANTY
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED
IN DURATION TO THE DURATION OF THIS WARRANTY.
For your convenience, Envirosource has established telephone numbers for frequently asked
questions:
To located the service center or dealer nearest you, or for service assistance or resolution of a service
problem, or for product information or operation, call:
Head-Office
2 Mercier street, Coburg Victoria 3058 Australia
Free Call 1800 174 424
www.envirosource.com.au
17
18
Download PDF