Installation and technical manual CHM Heater

Installation and technical manual
CHM Heater - wall mounting
Model
•
•
•
•
CHM 500 DSM
CHM 1000 DSM
CHM 1500 DSM
CHM 2000 DSM
•
•
•
•
CHM 500 RF
CHM 1000 RF
CHM 1500 RF
CHM 2000 RF
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY
AND RETAINED FOR FUTURE REFERENCE. BE SURE
TO OBSERVE ALL LABELS AND WARNINGS ON THE
APPLIANCE
Id.-Nr. 911 360 511
Edition :01/18
Feel good through warmth from electricity - www.technotherm.de |1
Installation and technical manual CHM heater
1. Important Safety instructions
• People (including children) who are limited in their physical, sensory, or
mental capacities should not use this device at any time. Furthermore do
not handle this instrument if you do not possess the necessary experience and knowledge to do so. This device should only be handled under the
supervision of a qualified person and after a thorough introduction.
• Do not leave children alone with the device, and supervise them at all
times to keep them from getting harmed.
GB WARNING: Do not cover! Otherwise this instrument will overheat.
• Do not place the heater underneath a socket, drainage or the like.
• To keep from getting burned, do not touch heater´s surface whenever it
is turned on.
• Please use the handle whenever you have to move the heater.Do not
put the cord underneath the carpet or a rug and make sure that it is not
a tripping hazard
• Plug the heater into properly grounded sockets only.
• Do not use the heater in any other way than described in the user manual. Any other way of use may lead to fire, electrocution, and may cause
serious harm to the person.
• Do not use this device near bathtubs, showers or swimming pools.
• In case the connection cable is damaged it has to be replaced by the manufacturer or someone commissioned by the manufacturer.
WARNING: Do not use a switching-oriented device, like a timekeeper, when
operating this heater. This could cause a change in the thermal adjustment
which is potentially hazardous!
• To keep the device from overheating do not put towels or clothing on top.
• When using the heater, make sure it is in an upright position and positioned on a even and dry place.
• Do not put any foreign objects into the vent. This may cause electrocution, fire or damage to the heater.
• Do not use an extension cord unless approved by an electrician.
• This device is for private use only, do not use in any other way than intended by the manufacturer.
• Do not use the device near curtains, highly combustible, extremely explosive or malleable materials.
• Keep a distance of a at least 1.0 m between combustible materials- like
furniture, cushions, bedding, paper, clothing, curtains-and the heating
device.
2| Feel good through warmth from electricity - www.technotherm.de
Installation and technical manual CHM heater
• Do not use the device in rooms were petrol, paint or any other flammable
liquids are stored.
• Do not use the device outside.
Warning! this device has to be grounded
This device may only be operated using alternating current and the operating
voltage indicated on the power rating plate
•
•
•
•
Nominal Voltage
Protection Class
Degree of Protection
Room Thermostat
230V AC, 50 Hz
I
IP 20
7°C till 30°C
GB
This devive is only for wall mounting
Feel good through warmth from electricity - www.technotherm.de |3
Installation and technical manual CHM heater
2.1 User Manuel for the CHM DSM model
For additional installation and registration of the DSM Thermostat and router please visit
http://www.lucht-lhz.de/lhz-app-gb.html and download the manual or ask our helpdesk.
3. User Manual CHM RF Model
GB
3.1.1 Setting the Room Thermostat
Press the receiver button for more than 3 seconds, until the indicator light begins to flash. Subsequently press the transmitter key in the configuration mode. (see User Manual Receiver) As soon as the indicator light stops flashing the two products are assigned.
3.1.2 Setting the sender
Press the receiver button for at least 3 seconds until the indicator light starts flashing.
Two modes of operation are possible.
Slow flashing: On\Off switch
Fast flashing: instigator
To switch the mode again, press the key briefly. Take the transmitter into the Configuration mode (see
user manual transmitter). Check that the indicator light is no longer flashing.
Application Example
The use of a room thermostat in combination with a opening detector is ideal, because the opening detector will detect if a window is open and will automatically switch to frost protection. By pressing the
receiver button for approximately 10 seconds, you can change the relay´s setting. You know the setting
is changed as soon as the signal light stops flashing.
3.1.3 Deleting Allocations
To delete the setting simply press the receiver key for approximately 30 seconds until you see the receiver light flash briefly. All transmitters are now deleted.
3.1.4 Receiver RF- Technical Specifications
•
•
•
•
•
•
•
•
Power Supply 230 V, 50 Hz +/-10%
Protection Class II
Expenditure : 0,5 VA
Switching capacity max.: 16 A 230 Veff Cos j =1 or max. 300 W with lighting control
Radio Frequency 868 MHz (NormEN 300 220),
Radio Range up to 300 m in an open field, indoors up to ca. 30m, depending on the
construction of the building and the electromagnetic interference
Maximal Number of receivers: 8
4| Feel good through warmth from electricity - www.technotherm.de
Installation and technical manual CHM heater
•
•
•
•
•
•
Mode of operation: type 1.C (Micro-disconnection)
Operating Temperature: -5°C to +50°C
Storage Temperature: -10 °C +70°C
Dimensions: 120 x 54 x 25 mm
Degree of Protection : IP 44 - IK 04
To be installed in average polluted Areas
WARNING
Do not install this device in areas that present an explosion hazard like a garage. Remove all protective coverage before turning on the device. When using the device for the first time you might detect
a strong odor. This is no reason for concern; it is caused by residues of production and will disappear
shortly.
The rising heat may cause stains on the ceiling, however this phenomena can be caused by any other
heating device as well. Only a qualified electrician may open or remove the device from the power
supply.
GB
4. Maintenance
Before cleaning the device be sure to turn it off. To clean use a damp towel and a mild detergent.
5. Assembly instruction
This Manual is very important and has to be kept at a safe place at all times. Be sure to hand this manual
to any other succeeding owner of the device.
The device is an electrical heater that was designed and intended to be mounted to walls. The device
comes with a power plug that has to be plugged into an outlet.
The device is designed to be connected to 230V (nominal) alternating current (AC).
Feel good through warmth from electricity - www.technotherm.de |5
Installation and technical manual CHM heater
5.1 Wall Installation
When installing the device, the safety distance must be strictly adhered to, so that flammable materials
can not ignite. Install the device to a wall which is heat resistant up to 90 ° C.
• Due to possible fire hazard the safety distances are observed during assembly:
GB
Side walls of the heater to any masonry:
Side walls of the heater to combustible materials: Distance radiator to the floor: arranged spaced upper radiator limit to about
components or covers (. Eg window):
flammable nonflammable 5 cm
10 cm
8 cm
15 cm
10 cm
To prevent inflammable materials from catching fire be sure to keep the prescribed safety distance
when installing the device. Mount the device to a wall that is fireproof up to 90 °C.
The safety distance to the floor should be 25 cm, and at least 10 cm to all other devices. Furthermore
there has to be safety distance of approximately 50 cm between the ventilation grille, windowsills, roof
slopes and ceilings.
If you want to install the device in your bathroom, be sure to keep it out of reach for people taking a
shower or a bath.
When mounting the device to the wall, be sure to keep to the dimensions as indicated in the illustration
on page 11. Drill two or three (if available) 7 mm holes and attach the corresponding plug. Then screw
the 4 x 25 mm screws into the holes, leaving a distance of 1-2mm between the head of the screw and
the wall. Hang the device in the two or three fittings and tighten it down. See also the additional mounting information at the following pages!
6| Feel good through warmth from electricity - www.technotherm.de
Installation and technical manual CHM heater
5.2 Mounting to the wall
GB
middle mounting only
at CHM 500
Model
Power
[Watt]
Width
A
[mm]
Height
B
[mm]
Depth
C
[mm]
D
[mm]
F
[mm]
G
[mm]
CHM 500
500
380
630
100
186
521
445
CHM 1000
1000
680
630
100
336
506
430
CHM 1500
1500
980
630
100
500
506
430
CHM 2000
2000
980
630
100
500
506
430
6. Installation of Electricity
The device was developed for an electrical voltage of 230 V(nominal) and an alternating current of (AC)
50 Hz.
The electrical installation may only be performed according to the user manual and only by a qualified
Electrician.
The device was designed to be used with termination and the connection cable has to be plugged into
an appropriate socket at all times. (Notice Permanent cables may not be used)
The distance between the receptacle and the device hast to be at least 10cm. The connection line may
not touch the device at any time.
In case the connection cable is damaged contact the manufacturer immediately!
Feel good through warmth from electricity - www.technotherm.de |7
Installation and technical manual CHM heater
Additional mounting information
1)
Drill three holes of 7mm and fix the wall bracket. Screw in the three 4 x 25 mm screws into the wall
2)
Click the heater first at the top into the wall bracket and then at the bottom. The heater will be fixed
“automatically”
Heater upper side
wall bracket: to be fixed
with 3 screws
GB
Heal is looked!
Push the screwdriver in
the hole down to unlock
Lower side of heater
Lower side of heater
Remove the heater from the heel
Heal is unlooked
1. Push with the screwdriver the heel down
2. Pull the heater away from the heel
8| Feel good through warmth from electricity - www.technotherm.de
Installation and technical manual CHM heater
Information requirements for electric local space heaters
From 01.01.2018, the EU conformity of these devices is additionally linked to the fulfillment of the Ecodesign requirements 2015/1188.
The installation and commissioning of the devices is only permitted in conjunction with external room temperature controllers that fulfill the following functions:
•
Electronic room temperature control with weekday control
And has at least one of the following properties:
• Room temperature control with presence detection
• Room temperature control with “open window” function
• with remote control option
• with adaptive start control
• with heating time limitation
Technotherm meets the following requirements and thus the ErP Directive:
•
•
Electronic room temperature control with weekday
control remote Control option
GB
Failure to comply with these requirements will result in the loss of the CE mark.
The additional operating instructions for setting up the thermostats and interfaces please ask in our support - see last page!
Model: CHM RF (Operation only permitted in conjunction with the thermostat TPF-Eco and the Eco-interface)
Item
Symbol
Value
Value
Nominal heat output
Minimum heat
output (indicative)
Maximum continuous heat output
Pnom
05
1,0
1,5
2,0
Value
kW
manual heat charge control, with integrated thermostat
NO
manual heat charge control with room and/or outdoor temperature
feedback
NO
electronic heat charge control with room and/or outdoor
temperature feedback
NO
fan assisted heat output
NO
Pmin
0,5
1,0
1,5
2,0
kW
Pmax,c
0,5
1,0
1,5
12,0
kW
Auxiliary electricity consumption
At nominal heat
output
elmax
0,5
1,0
1,5
2,0
kW
At minimum heat
output
elmin
<0,5
<0,5
<0,5
<0,5
W
In standby mode
Item
Type of heat input, for electric storage local space heaters only (select one)
Heat output
elSB
<0,5
y0,5
<0,5
<0,5
W
Type of heat output/room temperature control (select
one)
single stage heat output and no room temperature control
No
Two or more manual stages, no room temperature control
No
with mechanic thermostat room temperature control
N0
with electronic room temperature control
No
electronic room temperature control plus day timer
No
electronic room temperature control plus week timer
Yes
Other control options (multiple selections possible)
room temperature control, with presence detection
Contact Information:
No
room temperature control, with open window detection
No
with distance control option
Yes
with adaptive start control
No
with working time limitation
No
with black bulb sensor
No
Lucht LHZ Elektroheizung GmbG & Co. KG | Reinhard-Schmidt.Str.1 D-09217 Burgstädt
Subject to errors and technical amendments. Dimensions without guarantee! Edition 01/18
Feel good through warmth from electricity - www.technotherm.de |9
Installation and technical manual CHM heater
Information requirements for electric local space heaters
From 01.01.2018, the EU conformity of these devices is additionally linked to the fulfillment of the Ecodesign requirements 2015/1188.
The installation and commissioning of the devices is only permitted in conjunction with external room temperature controllers that fulfill the following functions:
•
Electronic room temperature control with weekday control
And has at least one of the following properties:
• Room temperature control with presence detection
• Room temperature control with “open window” function
• with remote control option
• with adaptive start control
• with heating time limitation
Technotherm meets the following requirements and thus the ErP Directive:
GB
•
•
•
•
Electronic room temperature control with weekday
distance control option
adaptive start control
room temperature control, with open window detection
Failure to comply with these requirements will result in the loss of the CE mark.
The additional operating instructions for setting up the thermostats and interfaces please ask in our support - see last page!
Model: CHM DSM (Operation only permitted in conjunction with the DSM-interface)
Item
Symbol
Value
Value
Nominal heat output
Minimum heat
output (indicative)
Maximum continuous heat output
Pnom
05
1,0
1,5
2,0
Value
kW
manual heat charge control, with integrated thermostat
NO
manual heat charge control with room and/or outdoor temperature
feedback
NO
electronic heat charge control with room and/or outdoor
temperature feedback
NO
fan assisted heat output
NO
Pmin
0,5
1,0
1,5
2,0
kW
Pmax,c
0,5
1,0
1,5
12,0
kW
Auxiliary electricity consumption
At nominal heat
output
elmax
0,5
1,0
1,5
2,0
W
At minimum heat
output
elmin
<0,5
<0,5
<0,5
<0,5
W
In standby mode
Item
Type of heat input, for electric storage local space heaters only (select one)
Heat output
elSB
<0,5
<0,5
<0,5
<0,5
W
Type of heat output/room temperature control (select
one)
single stage heat output and no room temperature control
No
Two or more manual stages, no room temperature control
No
with mechanic thermostat room temperature control
N0
with electronic room temperature control
No
electronic room temperature control plus day timer
No
electronic room temperature control plus week timer
Yes
Other control options (multiple selections possible)
Contact Information:
room temperature control, with presence detection
No
room temperature control, with open window detection
Yes
with distance control option
Yes
with adaptive start control
Yes
with working time limitation
No
with black bulb sensor
No
Lucht LHZ Elektroheizung GmbG & Co. KG | Reinhard-Schmidt.Str.1 D-09217 Burgstädt
TECHNOTHERM Support
+49 (0) 911 937 83 210
TECHNOTHERM a brand of Lucht LHZ GmbH & Co. KG
Reinhard-Schmidt-Str. 1 | 09217 Burgstädt
Telefon: +49 (0) 3724 66869 0
Telefax: +49 (0) 3724 66869 20
info@technotherm.de | www.technotherm.de
Subject to errors and technical amendments. Dimensions without guarantee! Edition 01/18
10|Feel good through warmth from electricity - www.technotherm.de
Download PDF