TOS1200 Datasheet - Advanced Test Equipment Rentals

®
Advanced Test Equipment Rentals
www.atecorp.com 800-404-ATEC (2832)
E stablished 1981
FOR ELECTRICAL SAFETY TESTERS
The separately sold accessories shown here can all be used with the withstanding voltage testers and insulation resistance testers
shown in this catalog with the exception of the limiting conditions for each item. Since some of these accessories may not be able
to be used with previous types not described in this catalog, please ask your dealer or the manufacturer when conditions are
unclear.
■Remote Control Box
This enables test on and reset operations to be performed by
remote control.
●RC01-TOS
[one-hand operation/dimensions: 200W × 70H × 39D mm]
●RC02-TOS
[both-hands operation/dimensions: 330W × 70H × 39D mm]
☛Accessory cable length: 1.5 m
Note:The optional Adapter DD-5P/6P (DIN to Mini DIN) is required for the connection with TOS7200
RC01-TOS
RC02-TOS
■DIN Cable
DD-3 5P [cable length: 3m
(For RC01-TOS, RC02-TOS)]
■High-Voltage Test Lead
●TL01-TOS [cable length: 1.5 m/max. operating voltage: 5 kV]
●TL02-TOS [cable length: 3 m/max. operating voltage: 5 kV]
●TL03-TOS [cable length: 1.5 m/max. operating voltage: 10 kV]
●TL04-TOS [cable length: 1.5 m/max. operating voltage: 5 kV (for TOS1200, RL01-TOS)]
●TL05-TOS [cable length: 1.5 m/max. operating voltage: 5 kV
(for TOS7000 series, 149-10A, RL01-TOS)]
●TL06-TOS
[cable length: 0.5 m/max. operating voltage: 5 kV
(for parallel connection of TOS9220/9221)]
●TL07-TOS
●TL08-TOS
●HTL-2.5DH
TL01-TOS
[cable length: 1.5 m/max. operating voltage: 5 kV (for TOS9220/9221)]
■High-Voltage Test Probe
(mainly for withstanding voltage testers)
These are handy probes for use with withstanding voltage
testers. These probes employ a design in which all test
switches on the probe can be pressed when holding onto the
probe by its grip.
●HP01A-TOS [cable length:
1.5 m/max. operating voltage:
4 kV AC (RMS), 5 kV DC]
●HP02A-TOS [cable length: 3
m/max. operating voltage: 4
kV AC (RMS), 5 kV DC]
■Low-Voltage Test Leads (for TOS6100/6200)
Test leads with alligator clips are to
be used exclusively for earth
continuity testing.
● TL11-TOS [cable length: 1.5 m /
max.operating current: 30A]
■Low-Voltage Test Probe (for TOS6100/6200)
This test probe is to be used exclusively for earth continuity
testing. Test on and reset can be performed using the switch
on the probe.
●LTP-2 [cable length: 2 m/
max.operating current: 30A]
[cable length: 1.5 m/max. operating voltage: 1 kV (for TOS7200)]
[cable length: 1.5 m/max. operating voltage: 10 kV (for 149-10A)]
TL02-TOS
TL03-TOS
TL04-TOS
■Warning Light Unit
This warning light unit is used
to indicate the status of
withstanding voltage testers (test
or judgement). This unit can be
turned on and off by a 100 V AC
input or a make contact signal.
* This can not be used with TOS6200,
●PL01-TOS
TOS9200/9201, TOS7200
TL05-TOS
TL06-TOS
TL07-TOS
TL08-TOS
HTL-2.5DH
☛Please contact your dealer or the manufacturer in cases when
electrically insulated gloves, electrically insulated rubber
sheets and so forth are required.
Copyright © 2002 KIKUSUI ELECTRONICS CORP. All rights reserved.
■Buzzer Unit
This buzzer unit is used when the volume obtained with the
electronic buzzer incorporated
in withstanding voltage testers
is not sufficient. This unit can
be turned on and off by a 100 V
AC input or make contact
signal.
* This can not be used with TOS6200,
TOS9200/9201, TOS7200
http://www.kikusui.co.jp/
●BZ01-TOS
Page1
OPTIONS
FOR ELECTRICAL SAFETY TESTERS
TOS1200
Outlines
Specifications
■Model TOS1200 Withstanding Voltage Tester Current
Calibrator: For calibration of current sensitivity of
withstanding voltage testers
❏Calibration of Leakage Current Detection Sensitivity
As a result of containing an internal test load resistor, the
TOS1200 enables switching of ammeter sensitivity and load
resistance values automatically for easy calibration of the
sensitivity of leakage current detection.
❏Direct Reading of Error from Error Display Scale
The main scale consists of an error display scale ranging
from -10% to +10% around a central full scale value. Thus,
if the leakage current detection sensitivity of the withstanding
voltage tester is a value of 1, 2 and 5 steps or 1, 2, 4 and 8
steps, the error can be read directly from the scale. The
auxiliary scale consists of a ratio display scale in which the
full scale value is taken to be 1.1, thereby enabling
accommodation of values outside the range of the main scale.
❏Ammeter Ranges
The ranges of the ammeter consist of 0.5, 1, 2, 5, 10, 20, 50
and 100 mA, and values equal to 0.8 times those values can
be set. This is convenient for withstanding voltage testers
of the type in which leakage current detection sensitivity is
set digitally (1, 2, 4 and 8 steps).
❏Eliminates Need for Power Supply
The TOS1200 offers outstanding portability since it does
not require a power supply.
❏AC/DC Selection Switch
Measuring Function
Copyright © 2002 KIKUSUI ELECTRONICS CORP. All rights reserved.
Measurement of current values and
error (%) for AC (50/60 Hz) and DC at
a test voltage of 1000 V
8 ranges consisting of 0.5/1/2/5/10/20/
50/100 mA along with values equal to
0.8 times the values of those ranges
(for 1, 2, 4 and 8 steps)
Main scale: Direct-reading error
display scale over a range of ±10% of
the above full scale values
Auxiliary scale: Ratio scale of 0 to 1.1
times the above full scale values
(equivalent to 0% display of main scale
when the ratio is equal to 1)
Main scale: ±1% of reading
Auxiliary scale: ±3% of full scale value
DC/AC(sine wave rms value
calibration of mean value response)
Measuring Ranges
Ammeter Scale
Ammeter Accuracy
Ammeter Indication
Load Resistance
Range[mA]
Resistance[kΩ]
Range[mA]
Resistance[kΩ]
0.5
2000
10
100
1
1000
20
50
2
500
50
20
5
200
100
10
Allowed Input Time
Dimensions (MAX)
Weight
Accessories
http://www.kikusui.co.jp/
0.5/1/2/5 mA ranges: Continuous
10/20/50/100 mA ranges: 60 sec.
Max. 1/3 of duty cycle
134W × 164H × 270D mm
(140W × 189H × 320D mm)
approx. 3.5 kg
TL04-TOS high-voltage test lead: 1
Page2