Digital Showering
Doccia Digitali
01
TDSSIG
0915
Sistema doccia digitale
Digital Shower System
Installation
Manual
Please note;
Tomorrow’s
shower, today
Thank you for using Intelligente – the
advanced digital showering system
from Tissino. Careful adherence to
the installation procedures and
maintenance practices set out in
this manual will ensure many years
of outstanding performance from
your new shower.
No part of this publication may be reproduced,
stored in a retrieval system or transmitted in
any form by any means, electronic, mechanical,
photo reproductive, recording or otherwise
without the prior written permission of Tissino.
This guide is subject to periodic review, update,
and revision. Customers are cautioned to make
sure that the guide’s information applies to the
system they are using.
This product performs as described in this guide
when assembled, operated, maintained, and
repaired in accordance with the instructions
provided. Do not repair this product or any of
its parts other than in accordance with written
instructions provided by Tissino or SmarTap.
6
Installation Options
19
07 Software Outlets Configuration
54
Important Safeguards
7
Plan System Layout
23
08 Final Inspection
58
Labels and Symbols
10
01 Prepare for installation
24
09 Maintenance
60
Technical Specifications
11
02 Prepare Infrastructure
26
10 Troubleshooting
64
Package Contents
13
03 Connect E-Valve and
Connect Pipes
38
Notices
67
System Dimensions & Mechanical Specifications
14
04 Connect Controllers
44
Tools
17
05 Install Power Supply
48
Hydraulic Characteristics
18
06 Connect Cables to E-Valve
50
Intelligente Series
Introduction
4
T 0845 582 8000
Einfo@tissino.co.uk
Wtissino.co.uk
5
Introduction
This guide provides the information
necessary to install and operate the
Tissino Digital shower system in a safe
and efficient manner.
Please read and understand this guide
before operating the system. It is mandatory to follow the instructions in the
guide and the technical description in
order to avoid damage to the system.
If any part of this guide is not clear,
please contact Tissino Technical
Support at digital@tissino.co.uk for
clarification.
The manual includes several kinds of comments,
marked with specific statements and aimed to attract
user attention to a specific type of information.
The definitions of Warnings, Cautions and Notes used
in this document are as follows:
A warning highlights an essential operating or
maintenance procedure, practice, condition,
statement, etc., which, if not strictly observed,
could result in injury or death of personnel, or
long term health hazards.
A caution highlights an essential operating or
maintenance procedure, practice, condition,
statement etc., which, if not strictly observed,
could result in damage to, or destruction of,
equipment or loss of effectiveness.
A note highlights or clarifies an essential system
description, operating or maintenance procedure,
condition or statement.
6
Safeguards
Please read these instructions carefully
before installation.
Read Instructions
All the safety and operating instructions
should be read before system is
unpacked and installed.
The warranty will be void if the product is
not installed according to these instructions.
Tissino will not be liable for loss or damages
resulting from improper installation or use of
the product that is not in accordance with the
instructions specified below.
The contents of this guide are subject to
change without prior notice.
Retain Instructions
The safety and operating instructions
should be retained for future reference.
Follow Instructions
All installation and configuration
instructions should be followed.
T 0845 582 8000
Einfo@tissino.co.uk
Wtissino.co.uk
7
Intelligente Series
Intelligente Series
Important
Safeguards
Do not use the E-Valve system before
reading and understanding this guide.
All showers requiring an electrical
connection must be installed by
qualified personel following the
latest revision of BS 7671 (Wiring
Regulations) and certified to current
building regulations.
Be careful while unpacking; the system is fragile.
Before any electrical
connections are made, the electricity
supply must be turned off at the mains
switch. All electrical
installation must be carried out only by
qualified personnel.
To prevent damage in the
existing infrastructure It is
most recommended to check
for hidden pipes or cables
before drilling any holes.
Product MUST be installed by
qualified personnel, in accordance
with all current relevant statutes and
regulations, including but not limited to
building regulations and Water Supply
(Water Fittings) Regulations 1999.
Important
Pipes on both inlet and
outlets should be as short
as possible in order to avoid
reduction of flow rate at the
connected outlets.
Unauthorized modification may cause
poor performance of the E-Valve. Do
not make modifications to the valve as
this could adversely affect the performance of the valve and void the warranty. Tissino will not be liable under its
warranty or otherwise for personal
injury or damage caused by an unauthorized modification.
8
Important
Safeguards
T 0845 582 8000
Einfo@tissino.co.uk
The E-Valve should be installed in an
accessible location for maintenance
(and no warranty claim can be considered or liability accepted by Tissino
if lack of accessibility has prevented
maintenance).
The E-Valve must not be
installed in places where
either the ambient temperature
is likely to exceed 40°C or where
freezing may occur.
The Dial controls must not be installed
in places where the ambient temperature is likely to fall below 5°C or rise
above 60°C.
Wtissino.co.uk
9
Intelligente Series
Intelligente Series
Labels and
Symbols
Technical
Specifications
!
Labels and Symbols
The e-Valve system has the following labels and symbols.
!
Absolute Maximum Ratings
Miscellaneous
Working pressure
1 - 9 bar
Over pressure
16 bar
Burst pressure
35 bar
Hot water temperature
70�C
Ambient temperature
5 - 60�C
Relative humidity
90%
non-condensing
Supplied user interface
9m
cable length
Operational voltage
100 - 240V
50 - 60 Hz
Standards
Safety: EN 60335-1:2012
EN 60335-2-105:2005
EMC: EN 55014-1, EN 55014-2
CE, RoHS, WRAS
Recommended Conditions
Symbol
Description
Working pressure
Hot water temperature
Ambient temperature
Set point temperature
Read the Installation manual
!
!
Manufacturer
!
Class III Appliance
!
Read all documents including the User’s Guide
IPx5
!
!
IPx5Water projected by a nozzle (6.3 mm) against
enclosure from any direction shall have no
harmful effects.
Not for general waste
CE conformity marking
2 - 5 bar
50 - 65�C
10 - 25�C
cold water or
35 - 47�C
Do not use the system if these
conditions are not met.
Performance at
Recommended Conditions
Temperature accuracy
± 0.5�C
Flow accuracy
± 5% of full scale
Hydraulic performance
complies
with EN1111
standard
9 of 51
10
T 0845 582 8000
Einfo@tissino.co.uk
Wtissino.co.uk
11
Intelligente Series
Intelligente Series
Package
Contents
Package
Contents
!
!
Package Contents
Package Contents
The Tissino Digital Shower system package includes the following
Thecomponents:
Tissino Digital Shower system package includes the following
components:
!
!!
!
If the system parts show any kind of
mechanical damage, do not use the
system and contact a Tissino
representative for service.
!
!
Two Dial controller
!
!!
(If applicable) One Dial controller
Two Dial controller
(If applicable) One Dial controller
Two
(If
TwoDial
Dialcontroller
controller
(Ifapplicable)
applicable)One
OneDial
Dialcontroller
controller
!
•
!
!
e-Valve
e-Valve
Intelligente e-Valve
!
•
!
AC cord length: 1.5m
AC cord length: 1.5m
DC cord length: 1.5m
DC cord length: 1.5m
AC/DC Adaptor
AC/DC Adaptor
AC/DC Adaptor
AC cord length 1.5m
DC cord length 1.5m
!!
!
6 pin interface cable
9 m length
IP67 compatible
Two Dial controller cable
!
!
•
•
6 pin interface cable 7m length
IP67 compatible
(If applicable) One Dial controller
cable
• 6 pin interfaceWARNING
cable
!!
• 6 pin interface cable 7m length
•• 6 pin interface
9 m cable
length
6 pin interface
cable IF THE
PARTS SHOW ANY KIND OF
•• SYSTEM
66pin
interface
cable
7m
• IP67
compatible
99mmlength
pin
interface
cable
7mlength
length
MECHANICAL
DAMAGE,
DO NOT
USE THE
•
lengthIP67 ! compatible
•• AND
CONTACT A TISSINO
IP67
•Two
compatible
Dial
controller SYSTEM
One
Dial controller
IP67compatible
compatible
• IP67
REPRESENTATIVE
FOR
SERVICE.
IP67
compatible
(If applicable) One Dial controller
Two Dial controller cable
(if applicable)
(If
applicable)
One
cable
6 pin
interface
cable
(If
applicable)
OneDial
Dialcontroller
controller
Two
Dial
controller
cable
! of
14
51
Two Dial controller
cable
cable
cable
9m length
WARNING
WARNING
IF THE SYSTEM PARTS SHOW ANY KIND OF
IP67 compatible
WARNING
!!
!14
! of
14
of51
51
12
!
!!
13 of 51
13 of 51
T 0845 582 8000
IF
PARTS
KIND
OF
MECHANICAL
DAMAGE,
DO
NOT
USE THE
IFTHE
THESYSTEM
SYSTEM
PARTSSHOW
SHOWANY
ANY
KIND
OF
! MECHANICAL
DAMAGE,
DO
THE
SYSTEM
AND CONTACT
A TISSINO
MECHANICAL
DAMAGE,
DONOT
NOTUSE
USE
THE
SYSTEM
REPRESENTATIVE
FOR SERVICE.
SYSTEMAND
ANDCONTACT
CONTACTAATISSINO
TISSINO
REPRESENTATIVE
REPRESENTATIVEFOR
FORSERVICE.
SERVICE.
! of 51
14
Einfo@tissino.co.uk
Wtissino.co.uk
13
!
One Dial Controller
Intelligente Series
Intelligente Series
System dimensions &
mechanical specifications
!
!
e-Valve
e-Valve
e-Valve
!
System dimensions &
mechanical specifications
!
!
Two Dial Controller
!
!
!
!
!
!
! of 51
18
!
! of 51
18
17 of 51
!
!
!
14
T 0845 582 8000
Einfo@tissino.co.uk
!
!16 of 51
!16 of16
! 51of 51
Two Dial Controller
One Dial Controller
!
!
Intelligente e-Valve
Wtissino.co.uk
15
!
Intelligente Series
Intelligente Series
System dimensions &
mechanical specifications
Tools
!
!
One Dial Controller
Adjustable Wrench
!
Glasses
!
Adjustable Wrench
Grinder
Adjustable Wrench
Drill
!
(if applicable) For the One Dial controller, use a 62mm hole saw
! of 51
18
16
One Dial Controller
T 0845 582 8000
Einfo@tissino.co.uk
Wtissino.co.uk
17
Intelligente Series
Intelligente Series
Hydraulic
Characteristics
Installation
Options
Flow rate, mixed stream
(L/min)
40
30
The power cable must be
secured and chased into
20
the wall. It must not be left
exposed to keep it protected
in the event of a possible leak.
10
Please make sure that
the cable is installed by a
qualified electrician.
0
1
1
2
3
Dynamic pressure (bar)
Typical flow rate performance of E-Valve
at various inlet and outlet conditions
4
Shower - Concealed Installation
(In wall): Fixed head, Handset, Water Jet
Single outlet, open
Single outlet, resistance class C
Two or three outlets, open
18
T 0845 582 8000
Einfo@tissino.co.uk
Wtissino.co.uk
19
Intelligente Series
Bath - Concealed Installation (Under bath):
Fixed head, Handset, Bath overflow filler
20
Intelligente Series
Installation
Options
Installation
Options
The power cable must be
The power cable must be
secured and chased into
secured and chased into
the wall. It must not be left
the wall. It must not be left
exposed to keep it protected
exposed to keep it protected
in the event of a possible leak.
in the event of a possible leak.
Please make sure that
Please make sure that
the cable is installed by a
the cable is installed by a
qualified electrician.
qualified electrician.
Shower –Loft Mounted: Fixed head,
Handset, WaterJet
T 0845 582 8000
Einfo@tissino.co.uk
Wtissino.co.uk
21
Intelligente Series
Intelligente Series
Installation
Options
Plan System
Layout
For vertical installaton:
The power supply must be
installed above the e-Valve.
The power cable must be
secured and chased into
the wall. It must not be left
exposed to keep it protected
in the event of a possible leak.
Leave extra 15 cm space on
each side for future cable
Please make sure that
connections.
the cable is installed by a
qualified electrician.
1. Prepare the installation
for the e-Valve
2. Prepare installation location for controllers.
Bath – Loft Mounted (Under bath): Fixed head,
Handset, Bath overflow filler
3. Prepare installation
location for the AC/DC
power supply.
22
T 0845 582 8000
Einfo@tissino.co.uk
Wtissino.co.uk
23
Intelligente Series
Intelligente Series
Prepare for
Installation
Prepare for
Installation
If a boost pump is used to
feed the e-Valve, make sure
that the same pump feeds
both hot and cold inlet. It is
strictly prohibited to feed only
one of the e-Valve inlets by
01
a boost pump, or to feed its
inlets with two separate boost
pumps.
e-Valve Unit Terminals
Water inlet and outlet connectors
are located on the sides of the
e-Valve unit.
Prepare locations for e-Valve unit,
controllers and Power supply
SP and PEX Pipe
Copper pipes
It is forbidden to weld directly
1. Insert G BSP male
1. Weld a copper pipe to a
next to the unit. Minimum
male fitting.
distance from e-Valve body
connectors into all unit inlets
and outlets (x 5).
2. Proceed to installation
is 15cm. Use wetted rag to
2. Connect the male fitting to
prevent unit from receiving
the e-Valve terminals.
direct heat from the welding
procedure.
torch.
Use pipework of a sufficient
diameter to obtain the flow
rates supported by the
e-valve. Please refer to
hydraulic characteristics for
the supported flow rates.
24
T 0845 582 8000
Einfo@tissino.co.uk
Wtissino.co.uk
25
Intelligente Series
Intelligente Series
Prepare
Infrastructure
Prepare
Infrastructure
For dry-wall installation,
Make sure that the pipework
cut the width and height
is perpendicular to the e-Valve
dimensions in the wall.
so that there is no strain on
the fittings.
Prepare the Two Dial controller
mounting position.
Run the Two Dial control cable
from the location of the e-Valve
unit to the location of the Two Dial
controller – female end on e-Valve
side , male end on controller side.
Mark on each pipe its
02
designation.
Prepare the mounting location
according to the Two Dial
controller junction box
dimensions.
Prepare the One Dial
controller mounting position (if
applicable).
Prepare the mounting
location according to the One
Dial controllerjunction box
dimensions.
26
• Use 20mm Electrical conduits.
• Leave Extra cable at the
e-Valve side.
T 0845 582 8000
Einfo@tissino.co.uk
Wtissino.co.uk
27
Intelligente Series
Intelligente Series
Prepare
Infrastructure
Prepare
Infrastructure
Run the One Dial control cable
(if applicable) from the location
of the Two Dial controller to
the location of the One Dial
controller.
- Female end on Two Dial
controller side. Male end on One
Dial controller side.
02
• Use 20mm Electrical conduits.
• Leave extra cable inside the
conduit.
Prepare the tile
28
T 0845 582 8000
Remove bracket
Einfo@tissino.co.uk
Wtissino.co.uk
29
Intelligente Series
Intelligente Series
Prepare
Infrastructure
Prepare
Infrastructure
The up arrow inside the
box and the controller lock
Insert the Two Dial electrical
junction box into the tile. Press
on the box until the outer
setting touches the tile.
mechanism on the setting
(image) should point to the
ceiling.
Insert the Two Dial electrical
junction box into the tile. Press
on the box until the outer
setting touches the tile.
02
Attach the Two Dial junction
box to the tile with silicone/glue
from the inside.
Attach the Two Dial junction
box to the tile with silicone/glue
from the inside.
• Apply a thick layer of compound
to fully seal the internal
components.
• Apply a thick layer of compound
to fully seal the internal
components.
30
T 0845 582 8000
Einfo@tissino.co.uk
Wtissino.co.uk
31
Intelligente Series
Intelligente Series
Prepare
Infrastructure
Prepare
Infrastructure
(If applicable) Make a round
cut in the tile according to the
dimensions of the One Dial
junction box.
Finish the tiling of the wall
or continue to the next step.
02
Diameter 62 mm
Use a knife to remove the round
brackets of the junction box
to enable wiring connection.
Remove the one that is closest
to the Conduit cable.
32
T 0845 582 8000
Einfo@tissino.co.uk
Wtissino.co.uk
33
Intelligente Series
Intelligente Series
Prepare
Infrastructure
Insert the One Dial electrical
junction box into the tile.
Press on the box until the outer
setting touches the tile.
Prepare
Infrastructure
Leave 10 cm of cable outside
the box and secure the cable.
Insert the control cable
into the hole.
02
34
Attach the One Dial junction
box to the tile with silicone/glue
from the inside.
Insert the conduit to the
interface of the junction
box.
• Apply a thick layer of compound
to fully seal the internal
components.
Leave a few centimeters
inside the box.
T 0845 582 8000
Einfo@tissino.co.uk
Wtissino.co.uk
35
Intelligente Series
Intelligente Series
Prepare
Infrastructure
Finish the tiling of the wall
or continue to the next step.
02
36
T 0845 582 8000
Einfo@tissino.co.uk
Wtissino.co.uk
37
Intelligente Series
Intelligente Series
Connect e-Valve
and Connect Pipes
Connect e-Valve
and Connect Pipes
Pre-wash the hot and cold
03
inlet pipes before connecting
the pipes to the e-Valve.
Make sure that the hot/cold
inlet is connected to a water
inlet by the text “in1 (hot)”/”in2
(cold)” on the e-valve box.
Vertical installation
38
Horizontal installation
T 0845 582 8000
Einfo@tissino.co.uk
Wtissino.co.uk
39
Intelligente Series
Intelligente Series
Connect e-Valve
and Connect Pipes
Connect e-Valve
and Connect Pipes
If there are unused outlets,
seal them with a 1/2” male
plugs and reconfigure the
outlets’ configuration from the
application (see section “Error!
Reference source not found.”)
Make sure that the pipework
is perpendicular to the e-valve
03
so that there is no strain on the
By default, the diverting
fittings.
function of e-valve will cycle
the outlets in the following
order: out1, out2, out3. out1 is
Connect hot water and cold
water inlet pipes.
the default outlet. Connect the
different outlets accordingly.
Connect the outlet pipes according
to the marking on the pipes.
Make sure that the pipework
is perpendicular to the e-valve
so that there is no strain on the
fittings.
40
T 0845 582 8000
Einfo@tissino.co.uk
Wtissino.co.uk
41
Intelligente Series
Intelligente Series
Connect e-Valve
and Connect Pipes
Test for leaks
1. Open water main valve.
03
2. Conduct visual inspection for
leaks on the inlet pipes.
3. Close water main valve.
42
T 0845 582 8000
Einfo@tissino.co.uk
Wtissino.co.uk
43
Intelligente Series
Intelligente Series
Connect Controllers
Connect Controllers
Make sure that the o-ring of
the junction box is in place
1. Attach the controller to junction box.
Connect the cables to the Two
Dial controller:
04
2. Pull down to lock it in place.
• Two Dial controller– e-Valve.
• Two Dial controller – One Dial
controller (If applicable).
44
T 0845 582 8000
Einfo@tissino.co.uk
Wtissino.co.uk
45
Intelligente Series
Intelligente Series
Connect Controllers
Connect Controllers
Make sure that the o-ring of
04
the junction box is in place.
1. Attach the controller to the
junction box.
Connect the cables to the One
Dial controller:
2. Rotate clockwise to lock it
in place.
• Two Dial controller – One
Dial controller (If applicable).
46
T 0845 582 8000
Einfo@tissino.co.uk
Wtissino.co.uk
47
Intelligente Series
Intelligente Series
Install Power Supply
Install Power Supply
Make sure that you have
Do not plug the power supply
enough spare cable for
into the electrical outlet at
making drip loops on
this time.
both ends.
1. Hold the power supply up to the
installation location:
1. Hold the power supply up to the
installation location:
05
a. Make sure that the AC cord will
reach the electrical outlet.
a. Make sure that the AC cord will
reach the electrical outlet.
b. Make sure that the DC cord will
reach the e-Valve DC cable inlet.
b. Make sure that the DC cord will
reach the e-Valve DC cable inlet.
2. Mark the hole locations
3. Secure the power supply with
the cable clips to the wall.
48
T 0845 582 8000
Einfo@tissino.co.uk
Wtissino.co.uk
49
Intelligente Series
Intelligente Series
Connect Cables
to e-Valve
Connect Cables
to e-Valve
Remove e-Valve box cover
To remove the e-Valve cover
use a flat screwdriver. Insert
it in the designated place
and twist clockwise.
There is only one way to connect
each cable. Make sure that the
cable connector is fully inserted
into the interface.
Connect cables
06
1. Insert the cable into the e-Vale
through the cable inlet holes on
the sides of the e-Valve.
2. Gently connect the cable
connector to applicable interface
on main module. To do so, align
the projection of the cable’s
connector to the receptacle
keyway slot of the interface.
Remove electronics box
1. Press on the two
red handles to release the
electronics box.
2. Gently pull out the box.
Be careful, other cables are
connected to it.
50
T 0845 582 8000
Einfo@tissino.co.uk
Wtissino.co.uk
51
Intelligente Series
Intelligente Series
Connect Cables
to e-Valve
Insert electronics box
1. Insert the electronics box gently
until you hear the “Click” sound.
Connect e-Valve to electric source
06
1. Connect the e-Valve power
supply into the power plug.
2. Make drip loops on both ends
of the power supply cable.
52
T 0845 582 8000
Einfo@tissino.co.uk
Wtissino.co.uk
53
Intelligente Series
Intelligente Series
Software Outlets
Configuration
Software Outlets
Configuration
Connect to your e-valve using a
mobile device
Do not plug the power supply
into the electrical outlet at
this time.
07
Confirm operation
Wait until the e-Valve finishes
the Internal test. (Internal test
should take about 30 seconds).
• Inspect LED colour:
• Green light– Continue to the
next step.
• Red light – go to section
Troubleshooting.
54
If not all of the three outlets are in
use, the unused outlets must be
disabled. There are two steps to
disable an outlet:
1. Seal the unused outlet with a
1/2” male plug.
2. Disable the outlet in the e-Valve
via the software configuration tool.
• Press and hold the “ON/
OFF” dial of the controller for
approximately 5 seconds,
until the dials illuminate with
a yellow light.
• On your mobile device, open
the Wi-Fi settings and find a Wi Fi
network named “e-Valve”.
disabled using a
software configuration tool,
the device may not function
properly.
• Connect to this network.
All outlets that are not
connected must be properly
To disable the outlet via the
software configuration tool, follow
the steps opposite:
T 0845 582 8000
If a sealed outlet is not
sealed. otherwise in-wall
leakage may occur.
Einfo@tissino.co.uk
Wtissino.co.uk
55
Intelligente Series
Intelligente Series
Software Outlets
Configuration
Connect to the
configuration page
• Open a web browser.
• Enter the following URL:
http://192.168.1.1/advanced.html
- check this works
07
• e-Valve configuration page
will appear.
56
T 0845 582 8000
Einfo@tissino.co.uk
Wtissino.co.uk
57
Intelligente Series
Initial check
• Make sure that the inlets internal
and external check-valves(if
any) are open and the system is
pressurized in both inlets.
• Make sure that the hot water
that is supplied to the e-Valve
reaches a sufficient temperature
(> 400C).
08
58
Intelligente Series
Final Inspection
• Check the hot water, make sure
that the water is comfortably hot
(380C).
• Use the Flow dial to toggle
between outlets.
• Operation check:
• Make sure the water runs
continuously through the available
outlets, over the whole toggling
cycle.
• Turn on the system. Press on
the power dial on one of the
controllers.
• Make sure that there are no
leaks near the e-Valve inlet and
outlet terminals.
• Wait a couple of minutes for the
water temperature to stabilize.
T 0845 582 8000
Einfo@tissino.co.uk
Wtissino.co.uk
59
Intelligente Series
Intelligente Series
Maintenance
Backup Battery Maintenance
E-valve is equipped with
The system includes a backup
battery that ensures that the
water will not flow through the
system, even if the main power
supply fails. Once in a while,
depending on frequency of the
power failures, this battery must
be replaced.
internal stop-valves. Use a
flat screwdriver to close or
open the stop valves. The
internal stop valves are in open
position by default. Close the
stop valves when wetted
modules maintenance is
needed.
09
Backup battery
replacement indication
When the battery charge level
drops below a certain level, the
system will notify user when the
e-Valve is turned off: the dials
will illuminate with a yellow light
The system is designed to
perform self-checks during normal
operation. If a malfunction occurs
or if maintenance is required, the
user will be notified by dedicated
colours and blinking patterns
on the two dial and the one dial
controllers. If there is a notification
that is not covered in this manual,
please contact Tissino for further
assistance.
60
Maintenance
T 0845 582 8000
Einfo@tissino.co.uk
and the flow dial will blink in an
alternating pattern.
This indicates that the battery
must be immediately replaced.
However, the e-Valve will still work
normally.
When the battery charge level
reaches a critical level, the dials
will illuminate with a red light, the
flow dial will blink in an alternating
pattern and the system will not
allow the water to flow. This
indicates that the battery must be
immediately replaced to continue
using the e-Valve.
Wtissino.co.uk
61
Intelligente Series
Intelligente Series
Maintenance
Maintenance
There is a cable attached to the
Backup battery replacement
procedure
Choosing the right replacement battery
Please use only Lithium primary (non-rechargeable)
9V batteries and only from the following list of
manufacturers and part numbers:
Manufacturer
08
P/N
GP
GPCR
Energizer
LA522
Duracell
DL1604
Ultralife
U9VL-J-P
• Never use rechargeable
batteries with this product.
• Never use alkaline or carbon
zinc batteries with this product.
case from the electronics box.
battery case.
To replace the backup battery, do
as follows:
5. Remove the old battery and
disconnect the contacts pad.
1. Disconnect the e-Valve from
the main power supply.
6. Insert a new battery and
connect the contacts pad to it.
Press with your thumb
2. Remove e-Valve box cover
and wait until the internal LED
indicator switches off (See Step
30).
7. Insert the battery case into the
electronics box.
associated with the battery
3. Remove electronics box
(See Step 31).
4. Pull out the red backup battery
8. Insert the electronics box
gently into the e-Valve.
(See Step 33).
9. Close e-Valve box cover.
(See Step 34).
on the electronics box to
overcome the initial resistance
case locking mechanism.
When you insert the battery
case into the electronics box,
make sure that you hear a
“click” sound. This will ensure
that the case is secured inside
the electronics box. If you do
not hear the “click” sound, make
sure that the associated o-ring
is not jammed between the walls
of the electronics box and the
battery case.
62
T 0845 582 8000
Einfo@tissino.co.uk
Wtissino.co.uk
63
Intelligente Series
Intelligente Series
Troubleshooting
Issue
The dials do not light after
turning the system on
Troubleshooting
Guidelines to a solution
• Make sure that the system is connected to the main power supply
• Make sure that there is no power supply failure
• Make sure that the dials are connected to the electronics box
through dedicated cable
Issue
The water starts running
but stops after few seconds
• Make sure that both check valves are open
• Make sure that the internal LED colour on the electronics box is green
The dials light but the
water is not running
10
• Make sure that the outlets are configured properly; all valid outlets
should not be sealed
• Make sure that the inlet pressure is sufficient
• Unplug the system from the main power supply, wait for 1 minute and
The dials illuminate in
yellow/red and the flow
dial blinks in an alternating
pattern.
Guidelines to a solution
• If a boost pump is installed, make sure that it works properly
• Make sure that both inlets are fed either by the main water
supply or by a single two-channel boost pump
• Replace battery (refer to “ Backup Battery
Maintenance” section)
• Contact Tissino
plug it back again
• Disconnect the system from the main power supply
The flow rate is
insufficient
The system is alternatively
stopping and starting the
water flow when ON
64
• Make sure that the outlets are not stuck with limescale or debris
• Make sure that the inlet pressure is sufficient
Electronics box LED is red
• Open the e-Valve cover and remove the electronics box
• Check connection of all cables, especially the sensors cable
• Return the box back to the e-Valve, close the cover and connect
• Consult Tissino regarding the possibility to service the internal filter
the power supply
• IF the problem remains, contact Tissino
• Make sure that the inlet pressures are within the specified absolute
maximum rating limits
• Make sure that the hot and cold inlets are not mixed
T 0845 582 8000
Einfo@tissino.co.uk
Wtissino.co.uk
65
Intelligente Series
System Components
Intelligente Series
Notices
Warranty
Your digital shower system is
covered by a manufacturer’s
warranty against any defect under
normal operational circumstances
for 5 years.
This warranty covers defects in
products or workmanship directly
related to this product when
installed, maintained and
operated in accordance with the
instructions supplied.
Installation, maintenance
and operation that is not in
accordance with the instructions
provided, unsuitable conditions
and product modifications will
invalidate the warranty.
66
T 0845 582 8000
Einfo@tissino.co.uk
Wtissino.co.uk
67
T 0845 582 8000
Einfo@tissino.co.uk
Wtissino.co.uk
Lyncastle Road
Appleton Thorn
Warrington WA4 4SN
Download PDF