MP7 Quick - GIUGNO 2001
ISTRUZIONI PER L’USO / INSTRUCTION MANUAL
MP7 QUICK
TERMOMETRO
ISTANTANEO
A RAGGI INFRAROSSI
INSTANT INFRARED
THERMOMETER
THERMOMETRE
INFRAROUGE
INSTANTANE
0044
Fabbricante/ Manufacturer:
ML ASIA Ltd.
www.medel.it
Distributore/Distributor:
Medel S.p.A. • Via Micheli, 7 - 43056 S.Polo di Torrile (PR) Italy
Tel. 0521.315211 - Fax 0521.315212 - E-mail: info@medel.it
INSTANT
INFRAROT
THERMOMETER
Instant infrared thermometer
Instruction Manual
We congratulate you on your purchase of the MEDEL MP7
QUICK instant infrared thermometer.
The MEDEL MP7 QUICK instant infrared thermometer is a high
quality product incorporating the latest technology and tested in
accordance with international standards. With its unique
technology, MEDEL MP7 QUICK can provide a stable, heatinterference-free reading with each measurement. The instrument
performs a self-test every time it is switched on to always
guarantee the specified accuracy of measurements.
The MEDEL MP7 QUICK instant infrared thermometer is
intended for the intermittent measurement and monitoring of
human body temperature at home. It is intended for use on
people of all ages.
Please read these instructions carefully before using the instrument
and keep them in a safe place.
TABLE OF CONTENTS
1. THE ADVANTAGES OF MEDEL MP7 QUICK INSTANT
INFRARED THERMOMETER
2.
IMPORTANT SAFETY INSTRUCTIONS
3. PRODUCT DESCRIPTION
4. HOW THE MEDEL MP7 QUICK INSTANT
INFRARED THERMOMETER MEASURES TEMPERATURE
5. CONTROL DISPLAYS AND SYMBOLS
6. HOW TO RELOAD A NEW PROBE COVER
7. DIRECTIONS FOR USE
8. CHANGING FROM FAHRENHEIT TO CELSIUS
AND VICE-VERSA
9. ERROR MESSAGES
10. CLEANING AND STORAGE
11. REPLACING THE BATTERY
12. TECHNICAL SPECIFICATIONS
13. WARRANTY
18
19
20
20
21
22
23
24
25
26
27
27
29
17
1. THE ADVANTAGES OF MEDEL MP7 QUICK INSTANT INFRARED
THERMOMETER
Multiple Use (Wide Range Measurement)
MEDEL MP7 QUICK offers a wide range measurement feature
ranging from 0°C to 100.0°C (32.0°F to 199.9°F); the product
can be used as an ear thermometer to measure body temperature,
but it also can be used to measure surface temperature of
following objects:
• Milk surface temperature in baby's bottle
• Surface temperature of baby's bath
• Ambient temperature
Measurement in 1 second
The innovative infrared technology allows measurement of ear
temperature in only 1 second.
Accurate and reliable
Due to the unique probe assembly construction, the advanced
infrared sensor, and the complete calibration process this unit can
offer a very accurate and reliable ear temperature measurement.
Gentle and Easy to Use
• Special ergonomic design enables simple and easy use of the
thermometer.
• The MEDEL MP7 QUICK instant infrared thermometer can be
used without interference to daily lifestyle. A measurement can
be taken even while a child is sleeping.
• The MEDEL MP7 QUICK instant infrared thermometer is pleasant
to use for the children.
• The MEDEL MP7 QUICK instant infrared thermometer is less
threatening to a child than a rectal thermometer and more pleasant to use than an oral thermometer.
Auto-Display Memory
The product displays the last reading automatically for 2 seconds
when the unit is switched ON.
Safe and Hygienic
• No risk of broken glass or mercury ingestion.
• Completely safe for use on children.
• Disposable probe covers make it completely hygienic.
18
Fever Alarm
10 short beeps alert the patient that he/she may have fever.
2.
IMPORTANT SAFETY INSTRUCTIONS
• Never use the thermometer for purposes other than those it has
been intended for. Please follow the general safety precautions
when using on children.
• Always use the thermometer with a new undamaged probe cover
for each measurement to prevent infection.
Use only MEDEL original probe covers. Do not use broken or
dirty probe covers.
• Never immerse the MEDEL MP7 QUICK instant infrared thermometer into water or other liquids (not waterproof). For cleaning
and disinfecting please follow the instructions in the "CLEANING
AND STORAGE” section.
• Keep the instrument and the probe covers away from direct exposure to the sun and keep it in a dust-free, dry area at the temperature between 10° - 40° (50°F - 104°F).
• Do not use the thermometer if there are signs of damage on the
measuring tip or on the instrument itself. If damaged, do not
attempt to repair the instrument! Please contact your nearest
MEDEL customer service bureau.
• Earwax in ear canal may cause a lower temperature reading.
Make sure subject's ear canal is clean to ensure an accurate
reading.
• The MEDEL MP7 QUICK instant infrared thermometer consists of
high-quality precision parts. Do not drop the instrument! Protect it
from severe impact and shock. Do not twist the instrument and
the measuring probe!
WARNING:
• Please keep the probe covers out of the reach of children.
• Use of this thermometer is not intended as a substitute for consultation with your physician.
• Thermometer is not waterproof! Please NEVER immerse into
liquids!
19
3. PRODUCT DESCRIPTION (Pic. 1)
(1) Probe Cover
(2)
(3)
(2) Probe
(1)
(3) Start button
(4)
(4) LCD Display
(5)
(6)
(5) O/I button
(6) Battery Cover
Pic. 1
4. HOW THE MEDEL MP7 QUICK INSTANT INFRARED
THERMOMETER MEASURES TEMPERATURE
The MEDEL MP7 QUICK instant infrared thermometer measures
infrared energy radiated from the eardrum and the surrounding
tissue. This energy is collected through the lens and converted to a
temperature value. The measured reading obtained directly from
the eardrum (Tympanic Membrane) can ensure the most accurate
ear temperature. Measurements taken from the surrounding tissue
of the ear canal generate lower readings and may result in
misdiagnosis of a fever.
IMPORTANT:
• Use ever the probe cover
• Switch on the thermometer by pressing the O/I button
• Straighten the ear canal by gently pulling the middle of the ear
back and up
• Place the probe firmly into the ear canal, press the Start button
and keep the probe in the ear until the thermometer beeps to
identify the completion of the measurement.
20
5. CONTROL DISPLAYS AND SYMBOLS
LCD Display
Display
Meaning
Description
All segments
displayed
Press the O/I button to
run on the unit, all
segments will be
shown for 2 seconds.
Memory
The last reading will
be shown on the
display automatically
for 2 seconds.
Ready
Measurement
complete
Low battery indication
The unit is ready for
the measurement,
the °C or °F icon
will keep flashing.
The reading will be
shown on the LCD
display with the °C
or °F icon flashing, the
unit is ready again for
the next measurement.
When the unit is turned
on, the battery icon
will keep flashing to
remind the user to
replace the batteries.
21
6. HOW TO RELOAD A NEW PROBE COVER
Pic. 2
Pic. 3
Place a probe cover onto the Completely push the probe into
storage case hole with paper the probe cover holder hole
(Pic.3).
side upwards (Pic.2).
Pic. 4
Pic. 5
Take the unit, vertically After feeling a slight click, take
penetrate the probe into the out the probe with cover
centre part of the probe cover attached tightly (Pic.5).
(Pic.4).
NOTE
• In order to avoid cross-contamination, please reload a new
probe cover for each patient.
• Please check if the probe cover is fitted on firmly before use (fig.
6). If the probe cover is broken, discard the probe cover and
reload a new one immediately.
Pic. 6
22
7. DIRECTIONS FOR USE
IMPORTANT: Prior to every measurement, fit a new undamaged
probe cover on the measuring probe. Failure to do so or use of
a dirty, damaged or unfitted probe cover may result in incorrect
temperature measurement.
1. Press the O/I button. The LCD is activated
to show all segments for 2 seconds.
2. The last measurement reading will be
shown on the display automatically
for two seconds with the „M“ icon.
3. When the °C or °F icon is flashing,
a beep sound is heard and the thermometer
is ready for the measurement.
4. Straighten the ear
canal by pulling the
ear up and back to
give a clear view of
the eardrum (Pic.8,9).
• For children under
1 year:
- Pull the ear
straight back
• Children aged
1 year to adult:
- Pull the ear up and
back (Pic.7).
Pic. 7
Pic. 8
5. While tugging the ear,
insert the probe snugly
Pic. 9
into the ear canal and
press the "START” button. Release it, when
you hear a beep
sound. This is the
reminding signal that comfirms the end of measurement.
6. Remove the thermometer from the ear canal. The LCD displays
23
the measured temperature.
IMPORTANT: 10 short beeps will sound when the temperature is
higher than 37.5°C in order to alert the patient that he/she may
have fever.
7. Replace the probe cover after each measurement. To do this,
please follow the instruction in point 6 „HOW TO RELOAD A
NEW AND CLEAN PROBE COVER?“.
8. In order to assure the accurate readings, please wait at least 30
seconds after 3-5 continuous measurements.
ADVICES FOR A CORRECT MEASUREMENT
• For an infant, it is best to have the child laying flat with his head
sideways so the ear is facing upwards. For an older child or
adult, it is best to stand behind and slightly to the side of the
patient.
• Always take the temperature in the same ear, since the temperature readings may be different from the right ear and left ear.
• Please wait for a few minutes to take the ear temperature after
sleeping.
• Take three temperatures in the same ear and consider the highest
one taken as the reading.
8. CHANGING FROM FAHRENHEIT TO CELSIUS AND VICE-VERSA
The MEDEL MP7 QUICK instant infrared thermometer can display
temperature measurements in either Fahrenheit or Celsius. To
switch the display between °C and °F, simply turn OFF the unit ,
press and hold the Start button for 5 seconds. When you stop
pressing the Start button after 5 seconds, the current measurement
scale (°C or °F icon) will be flashed on the display. Toggle the
measurement scale between °C and °F by pressing the start
button again. When the measurement scale has been chosen,
wait for 5 seconds and the unit will enter the ready for measuring
mode automatically.
24
9. ERROR MESSAGES
Display /
Problem
Display
Meaning
Possible cause and
fault remedy
Measured
Temperature too high
Displays „H“ when
measured temperature
higher than 100.0 °C
or 199.9 °F.
Measured
temperature too low
Displays „L“ when
measured temperature
lower than 0 °C or
32.0 °F.
Ambient temperature
too high
Displays „H“ in
conjunction with the
"▲" when ambient
temperature is higher
than 40.0 °C or
104.0 °F.
Ambient temperature
too low
Display „L“ in
conjunction with the
"▼" when ambient
temperature is lower
than 16.0 °C or
60.8 °F.
Error function
display
When system has
malfunction.
25
Display /
Problem
Display
Meaning
Possible cause and
fault remedy
Blank display
Please check if the
battery has been
loaded correctly. Also
check polarity (<+>
and <->) of batteries.
Dead battery
indication
If the steady battery
icon is the only
symbol shown on the
display, the batteries
should be replaced
immediately.
10. CLEANING AND STORAGE
Use a swab to clean the thermometer casing and a cotton swab
moistened with alcohol (70%
Isopropyl) to clean the measuring
probe (Pic.10). Ensure that no
liquid enters the interior of the
thermometer. Never use abrasive
cleaning agents, thinners or
benzene for cleaning and never
immerse the instrument in water or
other cleaning liquids. Take care
not to scratch the surface of the
LCD.
Remove the batter y from the
instrument if it is not required for
extended periods of time in order
to avoid damage to the
thermometer resulting from a
leaking battery.
26
Pic. 10
11. REPLACING THE BATTERY
The MEDEL MP7 QUICK instant infrared thernometer is supplied
with one lithium battery, type CR2032. Replace with a new
CR2032 battery when the flashing battery symbol appears on the
LCD display. Remove the battery cover and replace CR2032
battery (Pic.11).
Pic. 11
12. TECHNICAL SPECIFICATIONS
Type:
MEDEL MP7 QUICK Instant Infrared Thermometer
Measuring Range: 0 °C to 100.0 °C (32.0 °F to 199.9 °F)
Accuracy:
Laboratory: : ±0.2 °C, 32.0 ~ 42.2 °C
(±0.4 °F, 89.6 ~ 108.0 °F)
±1°C, 0 ~ 31.9°C, 42.3 ~ 100.0 °C
(±2 °F, 32.0 ~ 89.5 °F, 108.1~ 199.9°F)
Display:
Liquid Cristal Display with indicating unit
0.1 °C (0.1 °F)
27
Accoustic:
a. The unit is turned ON and ready for the
measurement: 1 short „bi“ sound.
b. Complete the measurement: 1 long
beep sound.
c. System error or malfunction:
3 short „bi“ sounds.
Memory:
Auto-Display the last measured temperature
Nite Glow:
a. The display will be lighted for 4
seconds when the unit is turned ON.
b. The display will be lighted again for
5 seconds when the measurement has
been completed.
Operating
temperature:
16 °C to 40 °C (60.8 °F to 104 F)
Storage/transport
temperature:
-25 °C to +55 °C (-13 °F to 131 °F)
Automatic
Switch-off:
Approx. 1 minute after last measurement
has been taken.
Battery:
CR2032 BATTERY (X1) - at least 1000
measurements
Dimensions:
141mm (L) x 26 mm (W) x 20 mm (H)
Weight:
45g (with battery), 40g (w/o battery)
Standards:
Complies with PrEN12470-5 requirements
28
MP7 Quick - GIUGNO 2001
ISTRUZIONI PER L’USO / INSTRUCTION MANUAL
MP7 QUICK
TERMOMETRO
ISTANTANEO
A RAGGI INFRAROSSI
INSTANT INFRARED
THERMOMETER
THERMOMETRE
INFRAROUGE
INSTANTANE
0044
Fabbricante/ Manufacturer:
ML ASIA Ltd.
www.medel.it
Distributore/Distributor:
Medel S.p.A. • Via Micheli, 7 - 43056 S.Polo di Torrile (PR) Italy
Tel. 0521.315211 - Fax 0521.315212 - E-mail: info@medel.it
INSTANT
INFRAROT
THERMOMETER
Download PDF