Performance Data Sheet
Model: High Flow Series/HF95 and HF95-S
Use Replacement Cartridge: HF95 or HF95-S
The concentration of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system as specified in NSF/ANSI Standard 42.
System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of substances as
listed below according to Standard 42.
Capacity: See chart on page 2
Contaminant Reduction Determined by NSF testing.
Substance Reduction
Chlorine Taste and Odor
Average
Influent
NSF/ANSI specified
Challenge
Concentration
Reduction
Avg %
Average Product
Water Concentration
Max Permissible Product
Water Concentration
NSF Reduction
Requirements
NSF Test
Report
2.0 mg/L
2.0 mg/L ± 10%
96.6%
0.07 mg/L
N/A
≥ 50%
J-00089365
FOR COMMERICIAL USE ONLY
Application Guidelines/Water Supply Parameters
Service Flow
See chart on page 2
Water Supply
Potable Water
Water Pressure
25 -125 psi (172 – 862 kPa)
Water Temperature
40º F - 100º F (4.4º C - 38º C)
It is essential that the manufacturer’s recommended installation, maintenance and filter
replacement requirements be carried out for the product to perform as advertised. See
Installation Manual for Warranty information.
Note: While the testing was performed under standard laboratory conditions, actual
performance may vary.
Replacement Cartridge: HF95 or HF95-S. For estimated costs of replacement elements
please call 866.990.9785 or visit our website at www.3Mpurification.com

3M Purification Inc.
400 Research Parkway
Meriden, CT 06450, U.S.A.
Tel 866.990.9785
203.237.5541
Fax 203.238.8701
www.3Mfoodservice.com
www.3Mpurification.com
Page 1 of 2
3M is a trademark of 3M Company.
© 2012 3M Company. All rights reserved.
NSF is a trademark of NSF International
INSTR4248 0912B
WARNING
To reduce the risk associated with ingestion of contaminants:
• Do not use with water that is microbiologically unsafe or of unknown quality without
adequate disinfection before and after the system.
CAUTION
To reduce the risk associated with property damage due to water leakage:
• Read and follow Use Instructions before installation and use of this system.
• Installation and use MUST comply with all state and local plumbing codes.
• Do not install if water pressure exceeds125 psi (862 kPa). If your water pressure exceeds 80
psi, you must install a pressure limiting valve. Contact a plumbing professional if you are
uncertain how to check your water pressure.
• Do not install where water hammer conditions may occur. If water hammer conditions exist you
must install a water hammer arrester. Contact a plumbing professional if you uncertain how to
check for this condition.
• Do not install on hot water supply lines. The maximum operating water temperature of this filter
system is 100º F (38º C).
• Protect filter from freezing. Drain filter when temperatures drop below 40ºF (4.4ºC).
• The disposable filter cartridge must be replaced every 6 months or at the specified service
cycle, or sooner, if a noticeable pressure drop occurs.
Performance Data Sheet
Model: High Flow Series
Use Replacement Cartridge HF95 or HF95-S
HF95 and HF95-S Cartridge Flow and Capacity Information
Head & Manifold
NH3-½ Series Head
# of Cartridges
Flow Rate
1
5 gpm (18.9 lpm)
1
5 gpm (18.9 lpm)
2
10 gpm (37.9 lpm)
3
15 gpm (56.8 lpm)
1
5 gpm (18.9 lpm)
2
10 gpm ( 37.9 lpm)
1
5 gpm (18.9 lpm)
2
10 gpm (37.9 lpm)
3
15 gpm (56.8 lpm)
1
5 gpm (18.9 lpm)
VH3 Series Head
Twin Manifold Assembly, 2XX
Series
Triple Manifold Assembly, 3XX
Series
DF Single Manifold Assembly,
DF 1XX Series
DF Twin Manifold Assembly,
DF2XX Series
DP Single Manifold Assembly,
DP 1XX Series
DP Twin Manifold Assembly,
DP2XX Series
DP Triple Manifold Assembly,
DP3XX Series
SF Single Manifold Assembly,
SF 1XX Series
Page 2 of 2
Flush Instructions
Flush 10.0 gallons through cartridge(s) before use
(flush approximately 2 minutes)
Flush 10.0 gallons through cartridge(s) before use
(flush approximately 2 minutes)
Flush 20.0 gallons through cartridge(s) before use
(flush approximately 2 minutes)
Flush 30.0 gallons through cartridge(s) before use
(flush approximately 2 minutes)
Flush 10.0 gallons through cartridge(s) before use
(flush approximately 2 minutes)
Flush 20.0 gallons through cartridge(s) before use
(flush approximately 2 minutes)
Flush 10.0 gallons through cartridge(s) before use
(flush approximately 2 minutes)
Flush 20.0 gallons through cartridge(s) before use
(flush approximately 2 minutes)
Flush 30.0 gallons through cartridge(s) before use
(flush approximately 2 minutes)
Flush 10.0 gallons through cartridge(s) before use
(flush approximately 2 minutes)
Capacity
54,000 gallons (204,390 liters)
54,000 gallons (204,390 liters)
108,000 gallons (408,780 liters)
162,000 gallons (613,170 liters)
54,000 gallons (204,390 liters)
108,000 gallons (408,780 liters)
54,000 gallons (204,390 liters)
108,000 gallons (408,780 liters)
162,000 gallons (613,170 liters)
54,000 gallons (204,390 liters)