INSTRUCTION
AND OPERATION
MANUAL
ESPRESSO COFFEE MACHINE
SERIE: 2 GROUPS
IBERITAL DE RECAMBIOS, S.A.
RIERA BLANCA, 49 08028 BARCELONA (SPAIN)
Tel. 34 93 632 64 55
Fax 34 93 632 71 33
IBERITAL DE RECAMBIOS, S.A.
TABLE OF CONTENTS
IMPORTANT INDICATIONS
1.- INSTRUCTIONS FOR THE USER (TURN ON)
1.1.1.2.1.3.1.4.1.5.1.6.1.7.-
Description
Preparation. Turn on
Programming the dose
Hot water output
Steam output
Daily cleaning operations
Water softener (not included)
2.- INSTRUCTIONS FOR THE TECHNICIAN
2.1.2.2.2.3.2.4.2.5.-
Description of the internal components
Water connection
Electrical connection
Feed unit (group)
Boiler
2.5.1.- Spring loaded safety valve
2.5.2.- Pressure eliminating valve
2.5.3.- Optical level control and automatic level device
2.5.4.- Valve unit
2.6.- Motor pump
3.- PRODUCT CERTIFICATIONS
Página 1 de 17
MANUAL IBERITAL JUNIOR INGLES
11/05/2007
IBERITAL DE RECAMBIOS, S.A.
IMPORTANT: READ CAREFULLY THE CONTENTS OF THIS MANUAL AS IT CONTAINS
IMPORTANT SAFETY INFORMATION REGARDING THE INSTALLATION, USE AND
MAINTENANCE OF THE APPLIANCE.
Read this manual before turning on the machine.
1) Keep this manual in a safe place for any eventual future consultation.
2) After unpacking, check that the machine is complete in all its parts.
The packaging (plastic bags, carton packing, nails, etc) must not be left within reach
of children as they are potentially dangerous items.
3) Before connecting the machine make sure that the values rated on the data plate (20) (located at
the left side) correspond to those of the mains supply.
The installation of the appliance must respect the local safety standards in force and must be
carried out, following the manufacturer's instructions, by technically qualified persons authorized
by IBERITAL DE RECAMBIOS, S.A.
The manufacturer accepts no responsibility for situations caused by or arising from the incorrect
installation of this appliance.
The safety of the machine can only be assured when it is correctly grounded to an efficient earth
connection, which has been carried out in conformity with the local safety standards and
regulations in force.
It is important that this fundamental safety measures must be verified, in case of doubt have the
system checked by a technically qualified person.
The manufacturer accepts no liability for damage caused by an incorrect or missing earth
connection.
Check that the current carrying capacity of the system is sufficient to cover the needs of the
maximum power consumption of the appliance, which is indicated in the data plate. In case of
doubt contact a technically qualified person who should also check that the cross section of the
cables used in the system are suitable to the maximum power consumption of the appliance.
The use of multiple adapters, patch cords and extensions are inadvisable.
Should the situation occur where the use of the above mentioned items is unavoidable then only
use single or multiple adapters and extensions which conform to the local safety standards and
regulations in force and take care not to exceed the maximum current carrying capacity marked on
the simple adaptors and extensions and maximum power consumption marked on the multiple
adapters.
MANUAL IBERITAL JUNIOR INGLES
11/05/2007
Página 2 de 17
IBERITAL DE RECAMBIOS, S.A.
4) This appliance must be used exclusively for the purpose for which it has been made; this means
for making coffee and supplying hot water and steam for making hot drinks. Any other use is to be
considered improper and therefore dangerous.
The manufacturer accepts no liability for damage caused by or situations arising from the
improper use of the appliance.
5) When using this machine there are several fundamental rules that must be observed such as:
- never touch the machine when you have wet or damp hands or feet.
- never use the machine with bare feet
- do not install the machine in places where cleaning is carried out using water
jets.
- never pull or jerk the power cable when removing it from the main socket.
- do not allow the machine to be exposed to atmospheric agents (rain, sand, ice,
etc.)
- do not leave the machine in places where the temperature is below
0 ºC without first having emptied the boiler and the hydraulic piping of water.
- do not allow the machine to be used by children, incapable persons, or any
body who have not read this manual.
-
never remove the cover of your machine for repairing or pushing the reset
safety switch. Only Official technicians are authorized by the manufacturer to
remove the cover and reset the machine.
6) Before carrying out any maintenance operations make sure that the machine is disconnected at the
mains either by tripping the circuit breaker.
7) For all cleaning operations follow the indications laid out in this manual.
8) In case any anomalies or irregular running, switch off the machine to attempt personal
maintenance operations. Contact a technically qualified person authorized by IBERITAL.
Any eventual repair work should be carried out by the manufacturer or by an authorized after sales
service center using original spare parts.
If the above is not respected the safety of the machine could be dangerous.
Página 3 de 17
MANUAL IBERITAL JUNIOR INGLES
11/05/2007
IBERITAL DE RECAMBIOS, S.A.
The connection to the mains must be carried out using a circuit breaker that conform to the local
safety standards and regulations in force.
9) During the installation the machine must be provided with a suitable automatic circuit breaker
which leaves a gap equal to or greater than 3 mm between its contacts.
10) In order to avoid dangerous overheating make sure that the power cord is completely extended
throughout its length.
11) The power cable must not be replaced by the user, if damage to the cable is noticed, disconnect the
machine from the mains and contact a technically qualified person authorized by IBERITAL.
12) Whenever the machine is not to be used for extended periods make sure it is disconnected from
the mains.
In order to guarantee the continued efficiency of the machine and its correct functioning it is
indispensable that the manufacturer's instructions be followed and the periodic maintenance be carried
out by professionally qualified person.
In particular it is recommended that the safety devices of the machine be periodically
checked.
Do not allow naked hands or other parts of the body to come close to the coffee
dispensing spout or the hot water or steam jets.
The water and steam escaping from the jets is extremely hot and cause burns.
The water jets, steam jets and the filter bowl are extremely hot during normal working
conditions. They must therefore be used with care and only gripped by the handless.
Make sure that the coffee cups are free of water before placing them on the cup
warning shelf.
Only crockery which is specific to this machine should be placed on the cup warning
shelf. In case of doubt, contact your sales center.
The placing of any other objects is therefore to be considered improper and dangerous.
MANUAL IBERITAL JUNIOR INGLES
11/05/2007
Página 4 de 17
IBERITAL DE RECAMBIOS, S.A.
TECHNICAL SPECIFICATIONS:
*
*
*
*
*
*
*
*
*
Electronic volume counter dosage (four different doses + Continuous).
Automatic water filled up of the boiler.
Motor and rotary pump pressure.
Manometer for the boiler pressure and pump pressure.
Electronic temperature control of the heating element.
Two steams outlet pipes in stainless steel.
One hot water outlet pipe.
Heating element 3000 W / 4000 W.
Easy location of the boiler drained-out cap.
DIMENSIONS
Wide
High
Long
475 mm
475 mm
460 mm
460 mm
690 mm
534 mm
Models
2 Groups
2 Groups compact
Important: Specifications are subject to change without notice. Contact the nearest
IBERITAL representative for any question related to the new specifications.
Página 5 de 17
MANUAL IBERITAL JUNIOR INGLES
11/05/2007
IBERITAL DE RECAMBIOS, S.A.
1.- INSTRUCTIONS FOR THE USER (TURN ON)
1.1.- DESCRIPTION
1) Coffee feed control buttons
2)
3)
4)
5)
6)
13) Three way power switch: OFF
1= (ON) (Automatic water fill-up ON)
2= Control (heating element ON).
14) ON/OFF red light
15) Drip tray
16) Data plate
17) Hot water valve control
18) Water stopcock (Not included. Must
be installed by an official city plumber).
22) Filter one coffee
23) Filter holder, one coffee
24) Filter two coffees
25) Filter holder, two coffees
26) Cleaning filter (blind)
Feed button, one espresso coffee
Feed button, two espresso coffees
Non-stop coffee feed button
Feed button, one large coffee
Feed button, two large coffees
7) Steam valve control
8) Hot water jet
9) Steam jet
10) Pump pressure gauge
11) Boiler pressure gauge
12) Mains switch (Non included. Must be
Installed by an official city technician).
IBERITAL junior
Electronic
Semiautomatic
10
11
1
17
1
7
7
14
13
9
9
15
16
12
18
8
2
5
3
6
4
1.2.-
MANUAL IBERITAL JUNIOR INGLES
11/05/2007
Página 6 de 17
IBERITAL DE RECAMBIOS, S.A.
PREPARATION - TURN ON
a) Turn on the water stopcock (18) at the mains.
b) Switch on the power at the mains (12).
c) Turn the switch (13) to the position 1 and wait for the automatic water level control
to finish filling up the boiler.
Only for 3 groups espresso machine: In case the automatic fill up control would stop and the
lights of the push buttons would flicker, turn the switch (13) off and immediately turn the switch
(13) on to the position 1 another time, and wait for the automatic water
control to finish filling up the boiler.
d) Turn the switch (13) to the position 2.
Wait for the operating pressure, indicated on the pressure gauge (11) (0,8-1bar).
The machine is heated by electricity.
1.3.- PROGRAMING THE DOSE
I.
TOUCH PATH PERFORMANCE
1 SHORT COFFEE (ESPRESSO)
1 LONG COFFEE
2 SHORT COFFEES
2 LONG COFFEES
CONTINUOUS
Página 7 de 17
MANUAL IBERITAL JUNIOR INGLES
11/05/2007
IBERITAL DE RECAMBIOS, S.A.
Important: The two touch path have electric signal with any of the two positions (1 and 2) of the OnOff switch.
In the position 1, the automatic fill up is working, but the touch path cannot make any coffee
(erogation).
In the position 2, it is possible to do coffees (erogations). But it is recommended to begin doing coffees
(erogations) when the machine is warm.
II. ADJUSTING THE TOUCH PATH DOSING.
Press the continuous button of the right hand group (group 1) during 5 seconds and the continuous LED will
light on.
In this moment, the adjustment process of the 4 selections can begin:
Press 1 short coffee button, and when you will have the dosing desired press another time the 1 short
coffee button. Now, you can continue with all the other selections. At the end, you have to wait until
the continuous LED will go out.
After this process, all the group are programmed automatically.
In the selections already adjusted, when you are programming any other selections, the LEDs are gone
out. At any time, you can adjust another time one selection already adjusted.
MANUAL IBERITAL JUNIOR INGLES
11/05/2007
Página 8 de 17
IBERITAL DE RECAMBIOS, S.A.
If during the adjustment of a dosing any of the LEDs are winking, the adjustment will not be
memorized. Please check the volumetric counter, in case there would be any dust from the water
supply.
III. ADJUSTMENT OF THE ELECTRONIC PRE-INFUSION
The pre-infusion can be enable and disable, as follows:
To enable this function:
1) Turn Off (position 0) the On-Off switch
2) Press the 1 short coffee (espresso) button of the left group (group 1) and at the same time
turn On the On-Off switch (to position 1 or 2).
3) The 1 short coffee (espresso) LED will light
4) Stop pressing the 1 short coffee (espresso) button
5) Turn Off (position 0) the On-Off switch
6) Finally, turn On the On-Off switch to the position 2 (normal working).
To disable this function:
1) Turn Off (position 0) the On-Off switch
2) Press the 1 long coffee button and at the same time turn On the On-Off switch (to position 1
or 2)
3) The 1 long coffee LED will light
4) Stop pressing the 1 long coffee button
5) Turn Off (position 0) the On-Off switch
6) Finally, turn On the On-Off switch to the position 2 (normal working)
IV. ALARM-WARNING SIGNALS
•
Boiler fill up exceeding time
The probe warning signal starts after 1 minute without being in contact with water. The alarm signal is:
winking all the touch path LEDs.
This alarm is due to a leak of water in the machine or the touch path is not sending any signal to the
auto fill up system.
Important: when you are doing the water fill up of the boiler process for the first time and this alarm
appears. Then, turn the On-Off switch Off (position 0) and following turn the On-Off switch On
(position 1) another time. (The fill up process takes more than 1 minute).
Página 9 de 17
MANUAL IBERITAL JUNIOR INGLES
11/05/2007
IBERITAL DE RECAMBIOS, S.A.
•
Failure in the volumetric counter (5 seconds)
The LED of the erogation being used (1 short coffee, 2 long coffee ...) is winking due to some failure
in the volumetric counter. At the same time, this erogation does not stop.
• Failure in the volumetric counter (erogation)
This alarm appears when the erogation time is too long. At the same time, this problem
appears when the coffee is ground too fine or too many grams.
1.4.- HOT WATER OUTPUT
Place a cup or other receptacle under the hot water jet (8). Turn on the control (17) to start the hot
water feed, release this button to stop it.
1.5.- STEAM OUTPUT
Point the steam jet (9) towards the drip tray (15).
Turn on the control (7), to discharge the condensation, until steam escapes from the opening.
Place the steam jet (9) into the recipient containing the liquid which is to be heated. Turn off the
control (7) to release the steam. To obtain a frothy cappuccino keep the jet level with the top of the
cold milk, this will create froth.
When the liquid has reached the desired temperature, stop the steam feed by turning the control (8) on
the contrary.
Slide the recipient out from under the steam jet (9). Point the stream jet (9) towards the drip tray (15).
Briefly turn the control (7) to the right, to discharge any residue which has remained in the steam jet
(9). Clean the outside of the steam jet (9) with a damp clothe or sponge.
1.6.- DAILY CLEANING OPERATIONS
Cleaning the spray filters
Every evening or at least once a day it is necessary to carry out the following:
Rinse the filters and filter bowls in hot water every evening or at least once during the day. Further still
allow them to soak overnight in water which is initially hot in order to dissolve the fat deposited by the
coffee.
Clean the spray jets and gaskets of the lower feed unit as follows:
MANUAL IBERITAL JUNIOR INGLES
11/05/2007
Página 10 de 17
IBERITAL DE RECAMBIOS, S.A.
- press the coffee feed button.
- place the filter holder (23) or (25), fitted with the cleaning blind filter (26), into the feed unit.
- Grip the filter holder at the end of the handle; rotate the filter holder to and through in order to allow
the hot water to have a rinse effect on the unit.
-
Clean the gasket of the lower feed unit group using a soft cloth or a sponge.
-
Clean the steam jets and cappuccinatore using URNEX milk frothier and steam jets cleaner.
Cleaning the groups
a) Substitute the normal filter (22) or (24) with the cleaning filter (blind) (26).
b) Place a couple of spoonfuls of detergent (bags of 20 gr. - Code 3852 URNEX – NSF approved)
into the cleaning filter (blind) (26).
c) Place the filter holder into the feed unit.
d) Switch on the unit and leave it working for several seconds (15-20").
e) Stop the unit by pressing the feed button a second time; during the decompression of the unit the
hot water and detergent will clean the feed group.
f) Repeat point (e) several times.
g) Rinse the unit and without the filter holder into the feed unit push any feed button to clean any
residual detergent.
Cleaning the outer shell of the machine
The external paneling of the machine should be cleaned with hot (not boiling) soapy
water and then rinsed thoroughly, using a soft cloth or a sponge. Do not use abrasive substances as
these could scratch the surface of the panels.
1.7.- WATER SOFTENER
The water softener eliminates calcium from the water therefore preventing the build up
of inlays. The water softener degenerates through use and must be regenerated. Regeneration is the
procedure which returns them to the original state. The presence of inlays in the boiler, through lack
of regeneration, will nullify all guarantees in force. (Water softener is not included).
Página 11 de 17
MANUAL IBERITAL JUNIOR INGLES
11/05/2007
IBERITAL DE RECAMBIOS, S.A.
2.- INSTRUCTIONS FOR THE TECHNICIAN
CAUTION: When the cover of the machine is removed in order to repair or push the
reset button, remember to seal another time the two side panels with NSF silicone.
2.1.- DESCRIPTION OF THE INTERNAL COMPONENTS
29) Pump
30) Boiler
2 groups 10,5 liters
31) Spring loaded safety valve
32) Pressure eliminating valve (Empty valve)
33) Boiler heating elements
34) Pressure switch
35) Expansion valve
61) Thermostat for the electronic temperature control of the heating element: this thermostat is to
control the temperature inside the boiler. When this temperature is over the correct level the
machine turns off (stop). In order to turn on the machine push the reset button located in this
thermostat (right side of the machine).
62) Boiler water level probe
2.2.- WATER CONNECTION
IMPORTANT: This Equipment is to be installed to comply with the applicable Federal,
State or Local Plumbing codes having jurisdiction.
2.3.- ELECTRICAL CONNECTION
IMPORTANT: This equipment is to be permanently cord connected.
The machine is fitted with heating and other electric elements of either 110V, 220V or 240V
depending on the version. A circuit breaker, with an adequately rated fuse, must be fitted between the
appliance and the mains. The maximum power consumption is indicated on the data plate (17).
The green wire must be connected to an efficient grounding installation.
MANUAL IBERITAL JUNIOR INGLES
11/05/2007
Página 12 de 17
IBERITAL DE RECAMBIOS, S.A.
220V-240V SINGLE PHASE.
The machine can be connected in single phase, in this case the black wire should be joined together
with the red wire and then connected to phase. The white wire must be connected to other phase.
Green wire to ground.
Black
Red
White
Green
--///
Phase (R)
Phase (S)
380V THREEE PHASE WITH NEUTRAL (TWO AND THREE GROUPS MACHINES)
The machine can be connected in three phases 380V with neutral. In this case the black wire and the
Red wire must be connected to one of the three phases, and the White wire to the neutral wire. The
green conductor/wire must be connected to ground.
Black
Red
White
Green
--///
R
S
T
N
Página 13 de 17
MANUAL IBERITAL JUNIOR INGLES
11/05/2007
IBERITAL DE RECAMBIOS, S.A.
2.4.- FEED UNIT GROUP.
44) Gasket
46) Spray head
47) Water drainage system
49) Solenoid valve
The feed unit consists of a hot press brass block in which the infusion chamber has been set.
Pressing the coffee feed button turns on the pump (29) and activates the solenoid valve (49).
2.5.- BOILER
50) Feed unit
52) Injector
53) Heat exchanger
This boiler is made of copper and is intersected by a heat exchanger (53) which is connected to the
feed unit (50).
During the feed cycle cold water is sent into the exchanger through the use of a pump
and injector (52). Between the heat exchanger (53) and the feed unit (50) a thermo siphon circulation is
established, through the difference in temperature and the density of water
which maintains the unit and the correct temperature needed for making the coffee.
A thermostat (61) controls the temperature of the heating element inside the boiler, in order not to pass
over the correct rate. In this case the machine turns off. To be turned on press the resent button located
on the thermostat.
GROUPS
2
HEATING
ELEMENT
3000 W / 4000 W
MANUAL IBERITAL JUNIOR INGLES
11/05/2007
Página 14 de 17
IBERITAL DE RECAMBIOS, S.A.
2.5.1.- SPRING LOADED SAFETY VALVE
In the case of anomalies in the heating control pressure system the spring loaded safety valve (31),
located on the boiler guarantees the integrity of the boiler by releasing the excess pressure when the
boiler reaches 1.8 bar.
The safety valves are manufactured under strict conditions and respect severe technical criteria, they
are sealed after testing in the factory.
2.5.2.- PRESSURE ELIMINATING VALVE (empty valve)
This valve (32), which is located on the boiler, prevents depressurization inside the boiler therefore
avoiding the risk of liquids being sucked back through the steam jet.
2.5.3.- OPTICAL LEVEL CONTROL AND AUTOMATIC WATER LEVEL DEVICE
48) Solenoid valve
A probe (62) (consisting of a stainless steel rod which is in contact with the water inside the boiler)
positioned the water level in the optical level device (11). The probe is connected to the electronic
control (CPU)(1) signaling a low water level in the boiler. Then, the CPU switches on the pump (29)
and activates the solenoid valve, therefore allowing passing water until the correct water level in the
boiler has been reached.
2.5.4.- VALVE UNIT
35) Expansion valve (set to open at approx. 12 bar -/+1)
2.6.- MOTOR PUMP
59) Lock nut
60) Setting screw
Power consumption: 250W. The motor pump turns on when the coffee feed button is pressed,
increasing the pressure to the 8/9 bar required for making the coffee.
The motor pump is also controlled by the level device for the automatic fill-up of the boiler.
To regulate the pressure of the motor pump proceed as follows: release the lock nut (59) which fastens
the setting screw (60), loosen the screw (60) to reduce the pressure or tighten to increase the pressure.
After having finished tighten the lock nut (59).
Página 15 de 17
MANUAL IBERITAL JUNIOR INGLES
11/05/2007
IBERITAL DE RECAMBIOS, S.A.
Product certifications.
The product conforms the following Standards:
UL 197 Standard. (Safety for Commercial Electric Cooking Appliances)
CAN/CSA C22.2 NO. 109 (Commercial Cooking Appliances)
NSF4 (Standard for Commercial Cooking & Hot Storage Equipment)
Directive 89/336/EEC. (Electromagnetic Compatibility).
Directive 73/23/EEC and 93/68/EEC. (Electric Safety).
Under demand, IBERITAL DE RECAMBIOS, S.A. may supply equipments conforming other
standards.
CAUTION: Changes or modifications to the equipment not expressly approved by IBERITAL DE
RECAMBIOS, S.A., could result in violation of the product certifications.
Product marks.
Accordingly with the certifications, products may carry the following marks:
MANUAL IBERITAL JUNIOR INGLES
11/05/2007
Página 16 de 17
IBERITAL DE RECAMBIOS, S.A.
Declaración de conformidad CE
IBERITAL DE RECAMBIOS, S.A.
C/Agricultura, 21 Nave 12
08980 SANT FELIU DE LL.
BARCELONA
CE Declaration of conformity
Ref.: V703-54
Con la presente declaramos que las máquinas de preparación de café con las marcas
comerciales y los tipos indicados a continuación, son conformes con las Directivas CE que
les son de aplicación, de acuerdo con las Normas Europeas que se relacionan.
We hereby declare that the coffee machines, with the trademarks and types listed below,
conform with the applicable CE Directive, according to the European Standards listed.
Esta declaración quedará sin efecto en caso de que se realice cualquier tipo de modificación
del aparato que no haya sido explícitamente autorizada por la empresa.
This declaration shall not apply to machines modified without IBERITAL approval.
Marcas comerciales:
Trademarks:
“IBERITAL JUNIOR”
Tipos de máquina:
Machine type:
“ELECTRÓNICA” Modelo 2 grupos.
“ELECTRONIC” Models with 2 groups.
“SEMIAUTOMÁTICA” Modelo 2 grupos.
“SEMIAUTOMATIC” Models with 2 groups
Directivas aplicables:
Aplicable Directives:
Directiva de Seguridad en las Máquinas.
EC Machinery Directive.
89/392/CEE
Directiva de Baja Tensión.
EC Low Voltaje Directive.
73/23/CEE
Directiva de Compatibilidad Electromagnética.
EC Electromagnetic Compatibility Directive.
89/336/CEE
Normas armonizadas
Aplicadas:
Applied harmonized
Standards:
UNE EN 292-1, UNE EN 292-2
UNE EN 60335-1, UNE EN 60335-2-75/63335-2-15
UNE EN 50081-1, UNE EN 50082-1
Fecha (Date): 30/11/2006
Firmado por (Signed): Sr. Blai Farré Llort
Cargo (Position):
Director Técnico
Página 17 de 17