Blow-off Adjustment Air Economizing and Vacuum Level

CVX0260B Design B
CVM216P
Sensors
Emergency or Power Failure
Operating System (EOS)
The Convum MPS-23 sensor with display has two (2) individual
switch outputs with hysteresis setting for feedback and controls.
() Button
Use the button to change
setting mode and pre-set
desired value.
Switch (OUT 1)
Switch (OUT 2)
(Green LED)
(Red LED)
(Patent Pending)
The Emergency Operating System is designed to maintain and
continue the current operation mode of the vacuum generator
when an emergency or power failure occurs by an adjustable or
fixed vacuum level on the mechanical pressure sensor.
kPa
MODE
() Button
3-1/2 digit LED display
Setting Button
Use the button to change
setting mode and pre-set
desired value.
Display the measured
pressure value, each set
content and error code.
Change setting mode and
pre-set final desired value
Blow-off Adjustment
The volume of air during the blow-off function to release the
workpiece can be set by turning the needle adjustment up
or down. Access the needle adjustment through opening of
protective cover (topside).
Factory Settings
OUT 1 AIR ECONOMIZING
Vacuum
Pilot Valve
OUT 2 PART PRESENCE
Blow-Off
Adjustment Screw
Blow-Off
Pilot Valve
1
Hysteresis Mode
0
Hysteresis Mode
1
P_4, Hysteresis 9.5 inHg
0
P_3, Switch Point 10 inHg
1
n_1, Switch Point 18 inHg
n_2, Hysteresis 15.5 inHg
1
N.C. Below n_1, N.O. Above n_1 N.O. Below P_3, N.C. Above P_3
Units of Measure; inHg
Sensor settings must be set so that n_1 > n_2 and P_3 > P_4.
AIR ECONOMIZING SWITCH POINT IS FACTORY SET AT
18 inHg. ALL SYSTEM DESIGN PARAMETERS MUST BE
ANALYZED BEFORE CHANGING “n_1”. Air Economizing
function will be turned off by setting “n_1” above the maximum
vacuum pressure that the system can create.
It may be necessary to adjust the part presence Output 2 to avoid
false signals when vacuum is falsely created by tubing or fitting
flow restrictions in an open system.
Air Economizing and
Vacuum Level Control
The vacuum sensor Output 1 is configured normally closed and
turns off the vacuum pilot valve. This controlled vacuum level is
programmed on the sensor by adjusting “n_1” or Output 1. When
the desired vacuum level is reached, the system begins the aireconomizing function by closing the vacuum valve air supply and
allowing the internal check valve to maintain the vacuum level
until the blow-off solenoid valve is activated to release the part or
the hysteresis value (programmed “n_2”) of Output 1 is reached
to restore the vacuum to the original desired level.
Operation Mode
MODES
Normal Conditions
Emergency
or Power Failure
VACUUM ON
VACUUM OFF
BLOW-OFF
EOS
Air Economizing between
18-15.5 inHg
Idle
Blow-off On
Blow-off Idle
EOS Off
Vacuum On
Idle
Blow-off
On
Idle
EOS On
p
p
Vacuum On
Restore Power
p p
Idle
Vacuum On
Air Economizing
Function Resumes
Idle
4
Idle
Idle
EOS Off
CVX0260B Design B
CVM216P
Replacement Components
Item
Part Number
Description
1
CVK-S
Silencer
2 thru 7
CVK-F
Filter Kit
5
8, 9, 10
CVK-E
Filter Element
Output
Output
Channel 1
Channel 2
Input
1 2 3 4 5 6 7 8
L
K
MC72-4PD
Pilot Valve Kit
11
3PB119-00-L-3
CVX E-Stop Valve
12
CVM99821
Diaphragm Valve
13
ENC244
Cover (Not Shown)
14
PSCVXDNB
PSCVXD3B
PSCVXN3B
DeviceNet
M12 Discrete
18-Pin Discrete
15
MPS-V23C-NC
NPN Sensor
Sensor
VAC1 BL01 VAC2 BL02
1
Sensor
2
Aux. Power
PSCVXDNB
Filter
Cap 2
8
Filter O-ring
3
(M8x1.0)
PSCVXD3B
Valve Mounting
Screws (M3x18)
10
N
U
S
G
B
P
R
F
C
D
E
PSCVXN3B
Auxiliary Valve
Mounting Screws
(M2x25)
Pilot
9 Valve
Filter
5
Element
A
M
T
H
Sensors
1 Silencer
Filter
4
Housing
J
11
Gasket
11 Auxiliary
Valve
Sensor 15
Sensor
Mounting
Brkt. Screws
(M3x5)
Sensor
Mounting
Brkt.
6
Blow-off
Flow
Adjustment
O-Ring
(M14x1.5)
11 Auxiliary
Valve Gasket
Filter
Gasket
Sensor
O-Ring
(P5)
Generator
Mounting
Screws
(M4x35)
Sensor
Mounting
Screws
(M2x6)
Diaphragm
12
Valve
Vacuum
Port
Filter 7
Base
Diaphragm Valve
Mounting Screw
(M3x20)
M4 Spring Lock
Washers
Mounting Screw
(M5x1)
M4x10 (4)
Cover Mounting Screws
(Cover Not Shown)
Scheduled Maintenance
Contents
Filters – Periodic maintenance of the secondary vacuum filter
is necessary. The frequency of maintenance depends on the
environment and application. As the filter collects product from
the environment the maximum vacuum level potential and
response time may vary.
The CVX0260B is supplied with four (4) M5 x 1 Socket Head Cap
Screws to secure the unit to the optional mounting plate.
Silencer – Periodic maintenance of the silencer may be required.
The frequency of maintenance depends on the environment and
condition of the air supply.
5