ASSEMBLY AND INSTRUCTION MANUAL
UK
Scan 83 Series
Congratulations on your new Scan wood-burning stove
You have purchased a product by one of Europe’s leading manufacturers of wood-burning stoves, and we are sure that you will have years of
pleasure with your purchase. To make the best possible use of your stove, it is important that you follow our advice and instructions.
Read through this Assembly and Instruction Manual carefully before you start to assemble your stove.
Product registration number
Please indicate the product registration number at any enquiry
SCAN A/S - DK-5492 VISSENBJERG
2
CONTENTS
Table of contents
Technical data ................................................................................................... 3
Installation
Safety
Technical data and dimensions
Dimensional drawings
Type plate
Product registration number
Assembly ........................................................................................................... 10
Loose parts
Additional accessories
Disposal of packaging
Removal of packaging
Height adjustment of stove
Fresh air intake
Closed combustion system
Load-bearing subsurface
Floor plate
Existing chimney and pre-fabricated element chimney
Connection between stove and steel chimney
Requirements for chimney
Connection with 90° elbow pipe
Rotating base and 90° elbow pipe
Positioning
Distance to flammable materials
Fitting the flue connection piece in the top outlet
Fitting the flue connection piece in the rear outlet
Fitting the natural stone sides
Fitting the natural stone top
Heat-storage stones Scan 83 Maxi models
Mounting of the ceramic tiles
Instructions for use ....................................................................................... 25
CB technology
Primary air
Secondary air
Baffle plates
Ash container
Handle for riddling grate
Adjustment of air supply
The Clean Air Act
Instructions for operation .......................................................................... 27
Lighting
Handling fuel
Maintenance ................................................................................................... 29
Troubleshooting ............................................................................................. 33
Warranty ........................................................................................................... 34
TECHNICAL DATA
3
Installation
Safety
The house owner is responsible for ensuring that installation and
assembly are in accordance with national and local building regulations as well as the information provided in this Assembly and
Instruction Manual.
Any changes made to the product by the dealer, fitter or user could
result in the product and safety functions not functioning as intended. The same applies to the fitting of accessories or extra equipment
not supplied by Scan A/S. This could also be the case if parts that are
necessary for the operation and safety of the stove are dismantled or
removed.
When you install any kind of fireplace or stove, you must inform the
local building and housing authorities. In addition you are obliged
to have the installation inspected and approved by a local chimney
sweep prior to commissioning.
To ensure best possible functionality and safety for your installation,
we advise you to call a professional fitter. Your Scan dealer will be able
to recommend a qualified fitter in your area. For information on Scan
dealers, please go to http:// scan.dk.
Scan 83-1
Handle and trims
in black aluminium
Scan 83-2
Scan 83-5
Handle and trims
in brushed aluminium
Scan 83-3
Maxi with handle and trims
in black aluminium
Natural stones/tiles, handle
and trims in black aluminium
Scan 83-4
Maxi with handle and trims
in brushed aluminium
Scan 83-7
Maxi with natural stones,
handle and trims
in black aluminium
Scan 83-6
Natural stones/tiles, handle
and trims in brushed aluminium
Scan 83-8
Maxi with natural stones,
handle and trims
in brushed aluminium
TECHNICAL DATA
4
Technical data and dimensions
Materials
Intermittent operation in this context means normal use of a
wood-burning stove. In other words, you should let the fire die down
until only the embers are left before refuelling.
Steel plate, cast iron, galvanised sheet,
vermiculite
Surface treatment
Senotherm
Max. log length (vertical position)
approx. 117 kg
Weight Scan 83-3 / 83-4
approx. 125 kg
Weight Scan 83-5/6, natural stone/tile
The Declaration of Performance (DoP) is available from http://scan.dk
approx. 186/132 kg
Weight Scan 83-7 / 83-8
approx. 212 kg
Fresh air connection piece external diameter
100 mm
Flue connection piece internal diameter
144 mm
Flue connection piece external diameter
148 mm
Approval type
The Scan 83 Series is produced in accordance with type approval for
the product, which also covers the product’s Assembly and Instruction
Manual.
35 cm
Weight Scan 83-1 / 83-2
Intermittent operation
Tested in accordance with EN 13240
Scan 83 Series
Technical data
Unit
CO emissions at 13% O2
* 0.07
%
CO emissions at 13% O2
896
mg/Nm3
Dust @ 13% O2
23
mg/Nm3
Nox @ 13% O2
106
mg/Nm3
81
%
Efficiency
Energy efficiency index
108,5
Energy efficiency class
A+
Nominal output
5
kW
Chimney temperature EN 13240
227
°C
Temperature in flue connection piece
280
°C
Amount of smoke
5
g/sec
Negative pressure EN 13240
12
Pa
Recommended negative pressure in flue
connection piece
16
Pa
Required combustion air supply
14
Nm3/h
Wood
Wood
Fuel consumption
1.6
kg/h
Amount of fuel required to light
1.4
kg
Fuel
* based on 896 mg/Nm3
TECHNICAL DATA
5
132 ±20 ***
1064**
1162 *
1200
Dimensional drawing for Scan 83-1 and Scan 83-2
460
230****
481
230
* Height to beginning of
flue connection piece at top outlet
** Centre rear outlet
*** Centre of fresh air intakerear outlet
**** Centre of fresh air intakebottom
NAVN:
Scan 83
EMNE:
Målskitse Scan 83-1
VÆGT: N/A
MATERIALE:
DIMENSION:
STI:
TG.NR:
AREAL:
N/A
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
TECHNICAL DATA
6
13220
1064**
1162*
1410
Dimensional drawing for Scan 83-3 and Scan 83-4
230****
460
481
* Height to beginning of
flue connection piece at top outlet
230
** Centre rear outlet
*** Centre of fresh air intakerear outlet
**** Centre of fresh air intakebottom
NAVN:
Scan 83
EMNE:
Målskitse - Scan 83-2
VÆGT: N/A
MATERIALE:
DIMENSION:
STI:
TG.NR:
AREAL:
C:\Working Folder\Designs\Scan 83\90583002.idw
N/A
DATO:
23-01-2013
90583002
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
BC
TECHNICAL DATA
7
132 ±20 ***
1064 **
1162 *
1235/1222 (tiles)
Dimensional drawing for Scan 83-5 and Scan 83-6 with natural stones/tiles
460
230****
481
230
* Height to beginning of
flue connection piece at top outlet
** Centre rear outlet
*** Centre of fresh air intakerear outlet
**** Centre of fresh air intakebottom
NAVN:
Scan 83
EMNE:
Målskitse Scan 83 med fedtsten
VÆGT: N/A
MATERIALE:
DIMENSION:
STI:
AREAL:
N/A
TG.NR:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
TECHNICAL DATA
8
132 ±20 ***
1064 **
1162 *
1446
Dimensional drawing for Scan 83-7 and Scan 83-8 with natural stones
460
230****
481
* Height to beginning of
flue connection piece at top outlet
230
** Centre rear outlet
*** Centre of fresh air intakerear outlet
**** Centre of fresh air intakebottom
NAVN:
Scan 83
EMNE:
Målskitse Scan 83 Maxi med fedtstenstop
VÆGT: N/A
MATERIALE:
DIMENSION:
STI:
AREAL:
N/A
TG.NR:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
BC
TECHNICAL DATA
9
Type plate
Product registration number
All Scan wood-burning stoves are fitted with a type plate that specifies the approval standards and the distance to flammable materials.
All Scan wood-burning stoves are provided with a product registration number.
The type plate is located at the rear of the stove.
The product registration number is located at the rear of the stove.
Please make a note of this number at the frontpage; you will always
need to quote it when contacting your dealer or Scan A/S.
Type plate
Product
registration
number
Scan 83 - Series
Freestanding room heater fired by solid fuel
Standard:
EN 13240
EC no. 90583600
Minimum distance to combustible materials:
Side: 400 mm - Back: 100 mm - Front: 900 mm
DIBt Zulassungsnummer:
Scan 83
IALE:
83XXXXX
0,07% 896 mg/Nm³
CO emission at 13% O2:
Dust at 13% O2:
23 mg/Nm³
Flue gas temperature:
280°C
Nominal heat output:
5 kW
Efficiency:
81%
Ovn med Typeskilt og produktregistreringsnummer
EMNE:
TG.NR: 90583020
Fuel type:
Wood
Operation type:
DATO: 21-02-2013 SIGN: BC
VÆGT: N/A Intermittent
The appliance can be operated in a shared flue.
AREAL: N/A
Country Classification Certificate/Standard
Approved by Krog Iversen & Co A/S
EUR
Intermittent
EN 13240
RWE Power AG
DK-5492 Vissenbjerg©
:\Working Folder\Designs\Scan
83\90583020.idw
Klasse 2
300-ELAB-1904-NS Teknologisk Institut
Norway
NAVN:
EMNE:
Scan
83
15a
B-VG
FSPS-Wa
2197-EN-A
RWE
Power
AG
Austria
Schweiz LRV 11
VKF
RWE Power AG
MATERIALE:
Germany BStV
1 FSPS-Wa 2197-EN
RWE
Power AG
SION:
Angaben für Österreich
Wärmeleistungsbereich:
Brennstoffwärmeleistung:
Zulässige Brennstoffe:
Prüfbericht:
DIMENSION:
VÆGT: N/A
AREAL:
2,6 - 5,8 kW
7,2 kW STI: C:\Working Folder\Designs\Scan 83\90583020.idw
Scheitholz
FSPS-Wa 2197-A
Follow assembly- and instructions manual.
Use only recommended fuels.
Montage- und Bedienungsanleitung beachten.
Verwenden Sie nur empfohlene Brennstoffe.
1000
Ovn med Typeskilt og produktregistreringsnummer
Scan A/S DK 5492 Vissenbjerg
06-2013
N/A
DATO:
TG.NR:
21-02-2013
9058
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
B
ASSEMBLY
10
Loose parts
Removal of packaging
The flue connection piece and other loose parts are located in the
stove’s combustion chamber.
Check that the stove is not damaged before starting to install it.
The stove comes attached to a wooden pallet on delivery. To remove
the packaging, see the illustrations below.
SCAN 83, ALL TYPES:
• 4 screws for fastening flue connection piece
• Gasket for flue connection piece
• Glove
• Repair lacquer for coloured stoves
SCAN 83-5, 83-6, 83-7 and 83-8
• 7/9 m sealing tape
Additional accessories
• Small shaped floor plate in glass or steel
• Large shaped floor plate in glass or steel
• Small corner shaped floor plate in glass or steel
• Soapstone top plate for stove with rear outlet
• Soapstone top plate for stove with top outlet
• Heat-storage stones Scan 83 Maxi, 4 items approx. 40 kg
• Rotating base
• Tile sides
Disposal of packaging
Your Scan stove may come supplied with the following packaging:
WOOD PACKAGING: The wood packaging can be reused and after
final use can be incinerated as a CO2 neutral product or sent for
recycling.
FLAMINGO TOP: Send for recycling or waste disposal.
FOAM: Send for recycling or waste disposal.
PLASTIC BAGS: Send for recycling or waste disposal.
STRETCH FILM/PLASTIC FILM: Send for recycling or waste disposal.
Screws to be removed
NAVN:
Scan 83
EMNE:
Afmontage ovn på palle (skrue i front af ovn)
TG.NR:
90
Height adjustment of stove
Remove the screws and fittings for securing the stove to the pallet.
The stove has four adjustment screws under the stove. Use the adjustment screws to get the stove to stand straight and level.
To adjust the adjustment screws, see the illustrations below.
B
B
C
NAVN:
Scan 83
EMNE:
Afmontage ovn fra palle
VÆGT: N/A
MATERIALE:
DIMENSION:
STI:
11
ASSEMBLY
AREAL:
C:\Working Folder\Designs\Scan 83\90583032.idw
N/A
TG.NR:
DATO:
01-03-13
90583032
SIGN:
BC
Remove the screws for the cover plate in the base.
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
C
Screws to be removed
Lift off the front of the base.
Scan 83
E:
N:
12
ASSEMBLY
Fresh air intake
In a well-insulated house the air used for the combustion process
has to be replaced. This particularly applies to houses with mechanical ventilation. There are different ways of making sure that air is
exchanged. The most important thing is to ensure that there is a supply of air to the room where the wood stove is located. The external
wall vent must be located as close to the wood stove as possible, and
you must be able to close it when you are not using the stove.
National and local building regulations must be followed with regard
to connection of a fresh air intake.
Closed combustion system
You should use the closed combustion system for the wood-burning
stove if you live in a newly-built, airtight home. External combustion
air is connected through a ventilation pipe via the wall or floor.
It must be possible to shut off the ventilation pipe with a valve, when
the stove is not in use.
Minimum Ø100 mm ventilation pipe, maximum length: 6 metres
with a maximum of one bend.
If you want external combustion air via a wall, remove the cover plate
at the rear of the stove with a pair of cutting pliers. See the procedure
on page 17.
D
Connect external combustion air via the connection piece underneath the combustion chamber.
NOTE: if the stove has a fresh air connexion or closed combustion, the
ventilation pipe must be open, when the stove is in use!.
D
Adjustment screws
EMNE:
Justering af ovn
NAVN:
Scan 83
MATERIALE:
VÆGT: N/AJustering DATO:
af ovn 01-03-13
EMNE:
AREAL:
orking Folder\Designs\Scan
83\90583034.idw
DIMENSION:
STI:
TG.NR:
N/A
90583034
SIGN:
Krog Iversen
& Co
VÆGT:
N/AA/S
DK-5492 Vissenbjerg©
AREAL: N/A
C:\Working Folder\Designs\Scan 83\90583034.idw
BC
TG.NR:
DATO:
01-03-13
90583034
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
BC
External combustion air via wall
(109 x 152 mm)
External combustion air via floor
(D 185 mm)
ASSEMBLY
Load-bearing subsurface
All items in our product range come under the category of lightweight fireplaces and stoves and do not normally require any reinforcement of the beam structure. They can be positioned on ordinary
beams/floor.
You should of course make sure that the subsurface on which the
stove is positioned can indeed support the weight of the stove and,
where applicable, a steel chimney, if you have opted for this solution.
Floor plate
If you are placing the stove on a flammable floor, you must comply
with the national and local regulations on the size of any non-flammable subsurface required to cover the floor around the stove.
Your local Scan dealer can advise you on regulations concerning protection of flammable materials in the vicinity of your stove.
The floor plate’s function is to protect the floor and flammable material against any sparks that may occur.
A floor plate can be made of steel or glass, but the stove can also be
placed on clinker concrete, natural stone or similar materials.
This Scan wood-burning stove has an integrated floor plate at the
bottom and can thus be placed directly on flammable material
without the need for further protection underneath the stove.
13
Existing chimney and pre-fabricated element
chimney
If you intend to connect your stove to an existing chimney, it makes
sense to contact an authorised Scan dealer, or a local chimney sweep,
for advice. These experts will also let you know if your chimney needs
renovating.
When connecting a pre-fabricated element chimney, follow the
manufacturer’s connection instructions for the relevant chimney
type.
Connection between stove and steel chimney
Your Scan dealer, or local chimney sweep, can advise you on choosing
a make and type of steel chimney. This ensures that the chimney will
match your wood-burning stove. As a general rule, the length of the
chimney should not be less than 4 metres, measured from the top of
the stove. Specific weather or installation conditions might require a
different length.
Choosing the wrong length or diameter of steel chimney could
impair functionality.
Always comply exactly with the instructions provided by the steel
chimney supplier.
Requirements for chimney
The chimney must have a minimum internal diameter of 148 mm
and have a T400 designation, with G for the soot fire test.
Connection with 90° elbow pipe
If you opt to connect the stove with an elbow pipe, you should use a
curved elbow, as this gives a better draught.
Rotating base and 90° elbow pipe
To ensure optimum function of the rotating solution for the stove, it
is important that assembly be performed in a meticulous fashion by
a qualified fitter.
See the separate instructions supplied with the rotating base.
Small shaped floor plate for the Scan 83-series
NAVN:
Scan 83
EMNE:
Ovn med gulvplade
DIMENSION:
STI:
TG.NR:
VÆGT: N/A
MATERIALE:
AREAL:
DATO:
N/A
C:\Working Folder\Designs\Scan 83\90583021.idw
Large shaped floor plate for the Scan 83-series
21-02-13
90583021
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
BC
14
ASSEMBLY
Positioning:
Positioning your wood-burning stove
The stove must be set up so that the stove itself, the flue pipe, and the
chimney can all be cleaned.
Distance to furniture: 900 mm
You should however assess whether furniture or other items might
become excessively dry due to being too close to the stove.
National and local regulations governing safety distances for woodburning stoves must be complied with.
100
If the stove is to be connected to a steel chimney, the chimney requirements in terms of safety distances must be met.
400
Distance to flammable materials
These distances apply for an uninsulated flue pipe/insulated flue pipe, all the way down to the stove, having a minimum of 30 mm insulation.
Installation along a rear wall.
45° Corner installation
100
100
46
7
400
100
ASSEMBLY
15
900
Installation with rotating base
900
360°
360°
900
900
Flammable materials
can 83
16
ASSEMBLY
Fitting the flue connection piece in the top outlet
Tighten the flue connection piece with the screws provided and reposition the steel top.
The stove is prepared for a top outlet from the factory.
Lift the steel top plate off the stove.
E
Place the gasket on the flue connection piece
NAVN:
E
Scan 83
EMNE:
rking Folder\Designs\Scan 83\90583007.idw
90583007
NAVN:
EMNE:
Scan 83
STI: C:\Working Folder\Designs\Scan 83\90583026.idw
MATERIALE:
DATO: 31-01-2013 SIGN: BC
Gasket
DIMENSION:
TG.NR:
VÆGT: N/A
AREAL:
AREAL:
DIMENSION:
Afmontage topplade
N/A
TG.NR:
VÆGT:
4 x M5x10
mmN/A
screws
MATERIALE:
EMNE:
Montage dæksel i topafgang
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
Flue connection
piece
STI:
DATO:
N/A
26-02-2013
905
SIGN:
Krog Iversen & Co A/S
Montage røgstuds i topafgang
VÆGT: N/A
AREAL:
C:\Working Folder\Designs\Scan 83\90583019.idw
N/A
TG.NR:
9
DK-5492 Vissenbjerg©
DATO:
21-02-13
SIG
Krog Iversen & Co A
DK-5492 Vissenbjerg
an 83
ASSEMBLY
17
Fitting the flue connection piece in the rear outlet
Unscrew the stove’s heat shield and remove it.
The stove is prepared for a top outlet from the factory.
Using cutting pliers, cut off the cover plate from the rear plate and
the heat shield (only Scan 83 Maxi) at its securing points.
The gasket for the flue connection piece, flue connection piece and
screws can be found in the stove’s combustion chamber.
÷
Lift the steel top plate off the stove.
Heat shield
Maxi
Heat shield
remount
Scan 68
NAVN:
klargøring til vægbeslag
EMNE:
VÆGT: N/A
MATERIALE:
DIMENSION:
STI:
NAVN:
Scan 83
VÆGT: N/A
MATERIALE:
EMNE:
Afmontage
topplade
DIMENSION:
STI:
DATO:
N/A
SIGN:
Scan 68
EMNE:
TG.NR:
DIMENSION:
30-01-13
STI:
N/A
C:\Working Folder\Designs\Scan 68\90068058.idw
MATERIALE:
TG.NR:
AREAL: 90583007
N/A
DATO:
N/A
31-01-2013
C:\Working VÆGT:
Folder\Designs\Scan
83\90583005.idw
AREAL:
NAVN:
Afmontage dækplade i svøb, topafgang
EMNE:
AREAL:
klargøring til vægbeslag
90583005
SIGN:
VÆGT: N/A
AREAL:
BC
N/A
C:\Working Folder\Designs\Scan 68\90068058.idw
Krog Iversen & Co A/S
BC
DK-5492 Vissenbjerg©
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
king Folder\Designs\Scan 83\90583007.idw
NAVN:
Scan 83
EMNE:
Scan 83 varmeskjold maxi
VÆGT: N/A
MATERIALE:
DIMENSION:NAVN:
STI:
TG.NR:
Scan 83
AREAL:
C:\Working Folder\Designs\Scan 83\90583073.idw
MATERIALE:
EMNE:
N/A
DATO:
24-11-2015
90583
SIGN:
h
Afmontage
i sv
Krogdækplade
Iversen & Co A/S
DK-5492 Vissenbjerg©
VÆ
ASSEMBLY
18
Place the gasket on the flue connection piece
Gasket
Flue connection
piece
Tighten the flue connection piece with the screws provided.
NAVN:
Scan 83
EMNE:
Røgstuds med monteret pakning
VÆGT: N/A
MATERIALE:
DIMENSION:
Remove the cover from the stove’s rear outlet.
STI:
TG.NR:
AREAL:
DATO:
N/A
21-02-13
90583018
SIGN:
BC
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
C:\Working Folder\Designs\Scan 83\90583018.idw
F
Cover
Scan 83
EMNE:
Hul i varmeskjold
VÆGT: N/A
IALE:
SION:
TG.NR:
AREAL:
DATO:
N/A
05-03-13
90583039
SIGN:
BC
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
:\Working Folder\Designs\Scan 83\90583039.idw
F
4 x M5x10 mm screws
NAVN:
Scan 83
EMNE:
Montage røgstuds i topafgang
VÆGT: N/A
MATERIALE:
DIMENSION:
STI:
NAVN:
Scan 83
AREAL:
EMNE:
VÆGT: N/A
AREAL:
N/A
21-02-13
90
SIGN
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
Montage røgstuds i bagafgang
MATERIALE:
DIMENSION:
N/A
C:\Working Folder\Designs\Scan 83\90583019.idw
TG.NR:
DATO:
TG.NR:
DATO:
06-03-13
Krog Iversen & Co
ASSEMBLY
19
Fit the cover in the stove’s top outlet and tighten it.
Reposition the steel top.
H
I
I
H
4 x M5x10 mm screws
EMNE:
NAVN:
Scan 83
MATERIALE:
DIMENSION:
EMNE:
AREAL:
TG.NR:
DATO:
VÆGT:
N/A i topafgang
Montage røgstuds
23-01-2013
VÆGT: N/A
N/A
AREAL:
ng Folder\Designs\Scan
83\10583900-Manual.iam
STI: C:\Working Folder\Designs\Scan 83\90583019.idw
DATO:
10583900-Manual
SIGN:
kc
TG.NR:
21-02-13
90583019
SIGN:
BC
Scan A/S
Krog Iversen & Co A/S
NAVN: DK-5492
Scan 83Vissenbjerg© EMNE: Højdejustering af topplade
DK-5492 Vissenbjerg©
Højdejustering afVÆGT:
topplade
NAVN:
EMNE:
Scan 83
MATERIALE:
N/A
N/A
MATERIALE:
DIMENSION:
AREAL:
N/A
STI: C:\Working Folder\Designs\Scan 83\90583043.idw AREAL:
DIMENSION:
STI:
C:\Working Folder\Designs\Scan 83\90583043.idw
VÆGT: N/A
N/A
TG.NR:
DATO:
08-03-2013
90583043
TG.NR:
SIGN:
BC
DATO: 08-03-2013
Krog Iversen
& Co A/S
90583
SIGN:
DK-5492 Vissenbjerg©
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
B
ASSEMBLY
20
Fitting the natural stone sides
Remove the steel top plate and the cover plate in the stove’s base
The natural stones should be mounted in the described order.
Important! Start the mounting with stone No. 1.
Natural stones are made from a natural material and may therefore
vary in structure and form.
After mounting, clean the natural stones with water.
Scan 83-5, 83-6, 83-7 and 83-8 come supplied with loose natural stones
16
13 14 5 17
1
4 5 6 12
8
11
7
1 2 3 10
Scan 83
EMNE: Fedtsten
NAVN:
AREAL:
73,86 kg
2135183 mm^2
EMNE:
Fedtstensmodel, afmont plade for sokkel og topplade
VÆGT: N/A
DIMENSION:
STI:
DATO:
AREAL:
C:\Working Folder\Designs\Scan 83\90583045.idw
TG.NR:
VÆGT:
:\Working Folder\Designs\Scan 83\90583024.iam
Scan 83
MATERIALE:
samlet, Maxi
RIALE:
SION:
Cover plate in base
21-02-2013
90583024
SIGN:
Scan A/S
DK-5492 Vissenbjerg©
kc/SR
N/A
DATO:
TG.
15-03-2013
Krog Iversen &
DK-5492 Visse
ASSEMBLY
Shorten the sealing tape supplied (7 metres/9 metres) to suitable
lengths and attach to the sides of the stove as indicated below.
21
Scan 83-7 / Scan 83-8
Scan 83-5 / Scan 83-6
Sealing tape
Sealing tape
Sealing tape
Sealing tape
Sealing tape
Sealing tape
EMNE:
NAVN:
Paksnor for fedtsten
TG.NR:
VÆGT: N/A
AREAL:
er\Designs\Scan 83\90583025.idw
N/A
DATO:
25-02-13
Sealing
tape
90583025
Scan 83
EMNE:
Tætningsbånd for fedtsten Maxi
VÆGT: N/A
MATERIALE:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
BC
DIMENSION:
STI:
AREAL:Sealing
N/A
C:\Working Folder\Designs\Scan 83\90583044.idw
tape
DATO
Kr
DK
ASSEMBLY
22
Fit the natural stones and fit the cover plate to the base.
Reposition the steel top.
K
L
TG.NR:
EMNE:
NAVN:
MATERIALE:
VÆGT:
DIMENSION:
STI: C:\Working
AREAL:
N/A
DATO:
N/A
23-01-2013
10583900-Manu
SIGN:
kc
Scan A/S
DK-5492 Vissenbjerg©
Folder\Designs\Scan 83\10583900-Manual.iam
K
N:
Scan 83
EMNE:
TERIALE:
NAVN:
L
Scan 83
3 x M5x10 mm screws
Fedtstensmontage
EMNE:
TG.NR:
VÆGT:
N/A
Montage røgstuds
i topafgang
DATO:
90583046
SIGN: BC
15-03-2013
TG.NR:
90583019
BC
AREAL: N/A
Krog Iversen & Co A/S
2 x M5x12 RH socket
cap screws Krog Iversen & Co A/S
AREAL: head
N/A
DK-5492
Vissenbjerg©
C:\Working Folder\Designs\Scan
83\90583046.idw
DK-5492
Vissenbjerg©
83\90583019.idw
STI: C:\Working Folder\Designs\Scan
ENSION:
VÆGT: N/A
MATERIALE:
DATO:
21-02-13
SIGN:
DIMENSION:
NAVN:
Scan 83
EMNE:
Fedtstensmontage
NAVN:
Scan 83
VÆGT: N/A
MATERIALE:
MATERIALE:
DIMENSION:
DIMENSION: N/A
AREAL:
STI:
EMNE:
TG.NR:
Oversigt over ovne
DATO:
15-03-13
90583046
BC
VÆGT: N/A
SIGN:
DATO:
AREAL: N/A
Krog Iversen
& Co A/S
Kro
STI: C:\Working Folder\Designs\Scan 83\90583042.idw
DK-5492 Vissenbjerg©
C:\Working Folder\Designs\Scan 83\90583046.idw
DK
Scan 83
ACCESSORIES
Fitting the natural stone top
Heat-storage stones
You can buy a natural stone top as an accessory. Place the natural
stone top on top of the steel top plate.
Heat-storage stones are made from a special material with a high heat
capacity. The stones are heated when the stove is on and keep releasing
heat, after the fire has gone out. This extends the time over which the
stove remains warm.
Heat-storage stones are placed in the top of the stove, as illustrated
below.
Scan 83 Maxi models:
Scan 83-3, 83-4, 83-7, and 83-8
EMNE:
Fedtstenstopplade bagafgang
TG.NR:
VÆGT: N/A
E:
N:
23
AREAL:
DATO:
N/A
01-02-13
90583010
SIGN:
BC
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
orking Folder\Designs\Scan 83\90583010.idw
Only to be used at rear
outlet
NAVN:
Scan 83
MATERIALE:
DIMENSION:
STI:
EMNE:
Montage varmeakkumulerende sten
TG.NR: 9
The heat conductor plate must
DATO: the
VÆGT: be
always
mounted under
N/A
05-03-2013 SIG
heat accumulating stones
AREAL: N/A
Krog Iversen & Co A
C:\Working Folder\Designs\Scan 83\90583037.idw
DK-5492 Vissenbjerg
ACCESSORIES
24
Mounting of the ceramic tiles
Adjustment screws
for the top plate.
Please note that the tiles are made of natural materials, and therefore
they can vary in structure and form. There may be minor cracks in the
glazing which is especially visible in the bright colours.
A
Scan 83-5/ 83-6
Top flue outlet
Rear flue outlet
STI:
C:\Working Folder\Designs\Scan 83\90583060.idw
AREAL:
DIMENSION:
NAVN:
DK-5492 Vissenbjerg©
Krog Iversen & Co A/S
N/A
VÆGT: N/A
MATERIALE:
Scan 83
EMNE:
DATO:
27-02-2015
løsdele til kakler
TG.NR:
SIGN:
hms
90583060
Mount the tiles
with the fittings.
Don’t fasten the
fittings until the
tiles have been
adjusted in their
final position.
NAVN:
EMNE:
EMNE:
kakler topudg
TG.NR:
90583065
Adjust the tiles
DATO: 10-03-2015 SIGN: hms
MATERIALE:
VÆGT: 9,00 kg
Kakler
NAVN:the
EMNE:
TG.NR: 90583066
kakler topudg
scan
83Scan
NAVN:
EMNE: bagudg
TG.NR: 90583065
into
right
posi83
DIMENSION:
AREAL: 974014 mm^2
tion
with
these
Krog
Iversen
DATO:
kg
SIGN:& Co
MATERIALE:
VÆGT: 9,57 VÆGT:
hmsA/SSIGN: hms
TG.NR: 90583063
DATO:
9,00
kg 10-03-2015
MATERIALE:
10-03-2015
DK-5492 Vissenbjerg©
two
screws.
STI: C:\Working Folder\Designs\Scan 83\90583065.idw
DIMENSION:
AREAL:topudg
kakler
1009053 mm^2
NAVN:
EMNE:
TG.NR:
grundovn u kakler topafg
Scan 83
DIMENSION:
DATO:
10-03-2015
VÆGT: N/A
AREAL:
Scan 83
After mounting and
adjusting the lower
tile, push the steel
cover plate in place.
STI:
N/A
SIGN:
hms
AREAL:
der\CAD\Inventor 2015\Templates\Standard - Manual.idw
STI:
Krog Iversen & Co A/S
AREAL:
DK-5492 Vissenbjerg©
STI:
VÆGT: 9,00
C:\Working Folder\Designs\Scan 83\90583065.idw
DIMENSION:
90583065
& CoIversen
A/S
974014 mm^2Krog IversenKrog
& Co A/S
DK-5492
Vissenbjerg©
DK-5492 Vissenbjerg©
DATO:
kg
C:\Working
Folder\Designs\Scan 83\90583066.idw
MATERIALE:
974014 mm^2
scan 83
MATERIALE:
SIGN:
hms
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
C:\Working Folder\Designs\Scan 83\90583065.idw
NAVN:
10-03-2015
EMNE:
NAVN:
Scan 83
EMNE:
justering
topplade/dækplade topafg
VÆGT: N/A
MATERIALE:
DIMENSION:
STI:
NAVN:
Scan 83
EMNE:
hængsel kakler
MATERIALE:
DIMENSION:
STI:
AREAL:
STI:
AREAL:
AREAL:
N/A
C:\Working Folder\Designs\Scan 83\90583064.idw
C:\Working Folder\Designs\Scan 83\90583070.idw
DATO:
N/A
TG.NR:
10-03-2015
DK-5492 Vissenbjerg©
TG.NR:
DATO:
90583064
DAT
SIGN:
Krog Iversen & Co A/S
After adjusting the 90583067
tiles,N/Ayou can10-03-2015
fasten hms
N/A
Krog Iversen & Co A/S
all
screws. DK-5492
Vissenbjerg©
VÆGT:
C:\Working Folder\Designs\Scan 83\90583067.idw
DIMENSION:
VÆGT: N/A
SIGN:
Cleaning of the ceramic tiles
The tiles must be cold before being cleaned. Use only a special soap
that you can buy at your dealer.
hms
25
INSTRUCTIONS FOR USE
A
CB technology (Clean Burning)
Baffle plates
The stove is equipped with CB technology. In order to ensure optimal
combustion of gases released during the combustion process, air passes through a specially developed system of channels. The heated air
is conducted into the combustion chamber through the holes in the
rear lining of the combustion chamber and at the baffle plates. This
airflow is controlled by the rate of combustion and therefore cannot
be regulated. Wood must not be added above the CB rail.
The baffle plates are located in the upper part of the combustion
chamber. The plates hold back smoke, making sure it stays inside the
combustion chamber for a longer time before escaping through the
chimney. This reduces the flue gas temperature as the gases have
more time to dissipate heat to the stove. The baffle plates must be
removed for sweeping; see “Maintaining your wood-burning stove”.
Note that the baffle plates are made of porous, ceramic material,
and are liable to break easily. You should therefore handle them with
care. The baffle plates are subject to wear and tear and not covered
by the warranty.
Primary air
The primary air regulation mechanism is used for lighting the fire,
or to accelerate combustion when you add more wood. During continuous operation, the primary air vent can be 30% to 80% open if you
use hard wood fuel, such as oak and beech. You can close the primary
air vent if you use soft wood, such as birch or pine, for fuel.
Ash container
Open the door of the stove to access the ash container under the
combustion chamber.
Setting for normal load: 30-50%
The ash container must always be closed during operation.
Secondary air
The ash container must not be become too full and must therefore
be emptied at regular intervals.
Secondary air is pre-heated and fed indirectly to the fire. At the same
time, the secondary airflow cleans the glass pane to prevent build-up
of soot. If you over-restrict the secondary airflow, soot can build up
on the glass pane. The secondary airflow determines the heat output
from your wood stove.
Setting for normal load: 60-90%
Handle for riddling grate
The stove is equipped with a riddling grate that empties ash from the
combustion chamber down into the ash container when activated.
The riddling grate must remain half open during operation.
Baffle
plates
CB technology
Scan 83
M
EMNE:
Brændkammer
TG.NR:
VÆGT: N/A
LE:
B N/A
N:
AREAL:
DATO:
01-02-13
90583012
SIGN:
BC
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
Working Folder\Designs\Scan 83\90583012.idw
M
NAVN:
Scan 83
EMNE:
Rysterist - askeskuffe
DIMENSION:
STI:
AREAL:
C:\Working Folder\Designs\Scan 83\90583013.idw
Riddling grate
Closed - Open
EMNE:
Rysterist - askeskuffe
TG.NR:
VÆGT: N/A
TG.NR:
90583013
SIGN:
Handle DATO:
for riddling
01-02-13
grate
Krog Iversen & Co A/S
VÆGT: N/A
MATERIALE:
DATO:
01-02-13
90583013
SIGN:
BC
N/A
DK-5492 Vissenbjerg©
BC
N
n 83
INSTRUCTIONS FOR USE
26
The Clean Air Act 1993 and Smoke Control Areas
Under the Clean Air Act local authorities may declare the whole or
part of the district of the authority to be a smoke control area. It is an
offence to emit smoke from a chimney of a building, from a furnace
or from any fixed boiler if located in a designated smoke control area.
It is also an offence to acquire an “unauthorised fuel” for use within
a smoke control area unless it is used in an “exempt” appliance
(“exempted” from the controls which generally apply in the smoke
control area).
Adjustment of air supply, primary and secondary damper
N
The Secretary of State for Environment, Food and Rural Affairs has
powers under the Act to authorise smokeless fuels or exempt appliances for use in smoke control areas in England. In Scotland and
Wales this power rests with Ministers in the devolved administrations for those countries. Separate legislation, the Clean Air (Northern
Ireland) Order 1981, applies in Northern Ireland. Therefore it is a
requirement that fuels burnt or obtained for use in smoke control
areas have been “authorised” in Regulations and that appliances
used to burn solid fuel in those areas (other than “authorised” fuels)
have been exempted by an Order made and signed by the Secretary
of State or Minister in the devolved administrations.
Primary air
Secondary air
Further information on the requirements of the Clean Air Act can be
found here : http://smokecontrol.defra.gov.uk/
Your local authority is responsible for implementing the Clean Air Act
1993 including designation and supervision of smoke control areas
and you can contact them for details of Clean Air Act requirements”
0% to 100%
A
The secondary air valve has been modified, so that is does not close
completely but has an opening corresponding to the position used at
the lowest emission test.
You can use any type of wood as fuel.
This stove has been recommended as suitable for use in smoke control areas when burning wood.
F(1:5)
Ash container
Lukket
Ash container in closed position
F(1:5)
Refueling on to a low fire bed
Lukket
If there is insufficient burning material in the firebed to light a new
fuel charge, excessive smoke emission can occur. Refuelling must be
carried out onto a sufficient quantity of glowing embers and ash
that the new fuel charge will ignite in a reasonable period. If there
are too few embers in the fire bed, add suitable kindling to prevent
excessive smoke
Fuel overloading
The maximum amount of fuel specified in this manual should not be
exceeded, overloading can cause excess smoke.
Operation with door left open
Ash container in open position
F
Operation with the door open can cause excess smoke. The appliance
must not be operated with the appliance door left open except as
directed in the instructions.
Dampers left open
EMNE:
Operation with the air controls or appliance dampers open can cause
excess smoke. The appliance must not be operated with air controls,
appliance
or door left open except as directed in the instrucTG.NR: dampers
90583014
tions.
Spjæld og askeskuffe
Åben
VÆGT: N/A
AREAL:
N/A
ng Folder\Designs\Scan 83\90583014.idwÅben
DATO:
12-02-13
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
BC
B
F
INSTRUCTIONS FOR OPERATION
Environmentally-friendly operation
Avoid turning down your wood-burning stove to the point where no
flames are visible from the wood, as this leads to poor combustion
and low efficiency. The gases released from the wood will not be
burnt off due to the low temperature in the combustion chamber.
Some of the gases will condense in the stove and flue system as soot,
and this could lead to your chimney catching fire at a later point. The
residual smoke which exits the chimney will pollute the surrounding
area and cause an unpleasant smell.
3.
Lighting
We recommend the use of fire lighters, or similar products, which
are available from your Scan dealer. Using fire lighters helps light the
wood more quickly and keeps the combustion process clean.
Never use liquid lighting fuels!
Due to the large size of this stove’s combustion chamber, it is important that the wood used to light the fire is dry so as to generate
enough heat to ensure clean combustion.
The combustion chamber lining will turn black when the fire is lit. It
will burn clear again the next time wood is added.
4.
“Top down” lighting
4 pieces of wood approx. 20-25 cm long with a weight of approx. 0.40.5 kg per piece (illustrations 1 and 2).
15-20 thin pieces of firewood of about 20 cm in length, with a total
weight of approx. 0.8 kg (illustrations 3 to 5).
4 fire lighters in bag or block form
Place the pieces of wood, firewood and fire lighters in the combustion chamber as shown in illustrations 1 to 6.
Set the primary and secondary airflow controls to maximum for the
entire lighting phase.
Top down lighting is a more environmentally-friendly way of
lighting the fire and helps to keep the glass area as clean as possible.
1.
5.
2.
6.
Position fire lighters between the pieces of firewood.
27
28
INSTRUCTIONS FOR OPERATION
Continuous operation
General notes
It is important to obtain as high a temperature as possible in the
combustion chamber. This results in best possible use of the stove and
fuel, as well as achieving clean combustion. In this way you will avoid
build-up of soot on the combustion chamber lining and glass pane.
During operation, you should not see any smoke; just a movement in
the air that indicates combustion is in progress.
Please note! Parts of the wood-burning stove, especially the outer
surfaces, become hot during use. Due care should be exercised.
After completing the lighting phase, you should have a good layer of
embers in the stove; you can then start operation of it proper. Add two
pieces of wood at a time: they should be about 0.4 to 0.5 kg in weight
and about 20-25 cm long.
NB: The wood must catch fire quickly; this is why we recommend setting the primary airflow fully open. Operating the stove at too low a
temperature and with too little primary air can lead to gases igniting,
which can damage the stove.
When adding wood, always open the glass door carefully to prevent
smoke escaping. Never add wood while the fire is burning nicely.
Never empty ashes into a flammable container. Ashes can contain
glowing embers long after you finish operating the stove.When the
stove is not in use you can close the dampers to avoid a draught
through the stove.
If the stove has not been used for some time, you should check the
flue passageways for potential blockages before relighting.
Chimney fire
In the event of a chimney fire, keep the stove door, the ash container,
and all dampers on the stove closed. In an emergency, call the fire
brigade.
We recommend that you get a chimney sweep to check the chimney
before using the stove again.
Operating the stove in the spring or autumn
In the spring/autumn transition period, where there is less need for
heating, we recommend you light the stove “top down” once, perhaps
adding just two pieces of wood as above to ensure that the combustion chamber lining burns clean again.
The function of the chimney
The chimney is the wood-burning stove’s motor; its performance
determines how well your stove will work. The draught in the
chimney creates negative pressure in the wood-burning stove. The
negative pressure draws the smoke out of the stove and takes in air
through the combustion air damper to fuel the combustion process.
Combustion air is also used for the airwash system that keeps the
window clear of soot.
The draught in the chimney is created by the difference in temperature inside and outside the chimney. The higher the difference in
temperature, the better the draught. This is why it is important that
the chimney reaches operating temperature before you reduce the
damper settings to restrict combustion in the stove (a brickwork
chimney will take longer to reach operating temperature than a steel
chimney). It is very important that the operating temperature is reached as quickly as possible on days when the draught in the chimney
is poor due to unfavourable wind and weather conditions. You need
to get a few flames going as quickly as possible. Chop the wood extra
thin; use an extra fire lighter etc.
After longer periods without use, you must check the chimney flue
for blockages.
You can connect several units to the same chimney. You should however first check the relevant regulations in this respect.
No matter how good your chimney is, it will not perform well if you
do not use it correctly. Equally, a poor chimney may well give you
acceptable results if you use it correctly.
Using your stove in various weather conditions
The way the wind affects the chimney can have a big impact on how
your stove reacts under various wind loads; you may need to adjust
the airflow to achieve good combustion. Fitting a damper in the flue
pipe may also help, as it will allow you to regulate the draught under
changing wind loads.
Fog and mist can also have a big impact on chimney draught; you
may need to use other settings for the combustion air to achieve
good combustion.
Handling fuel
Selecting wood/fuel
You can use any type of wood as fuel. However harder woods, such
as beech or ash, are generally better for heating, as they burn more
evenly and create less ash. Other woods, such as maple, birch and
spruce, are excellent alternatives.
Preparation
The best fuel is obtained where the tree has been felled and the wood
sawn and split before May 1st. Remember to cut the wood to match
the size of the combustion chamber. We recommend a diameter of
6-10 cm. The length should be about 6 cm shorter than that of the
combustion chamber to leave enough space for air to circulate. If the
diameter of the wood is greater than the above, it should be split
down its length. Wood that has been split dries faster.
Storing
You need to store the sawn and split wood in a dry place for 1-2 years
before it will be dry enough to burn. Wood dries faster if you stack
it in an airy place. Before using it, it is a good idea to store the wood
for a few days at room temperature. Remember that wood absorbs
moisture from the air during autumn and winter.
Moisture
To avoid problematic impact on the environment and to ensure optimum operating economy, the wood should be perfectly dry before it
can be used as fuel. Maximum wood moisture content should not
exceed 20%. A moisture content of 15-18% will deliver best efficiency.
An easy way of checking wood moisture content is to knock the ends
of the two pieces of wood together. If the wood is moist, the sound
will be slightly muffled.
If you use wood that is too damp, most of the heat it produces will
be used up in evaporating the water. The stove will accordingly not
increase in temperature, nor emit heat to the room as a result. This is
obviously poor economy, and it will cause soot build-up on the glass
pane, in the stove and in the chimney. Operation using moist wood
also pollutes the environment.
MAINTENANCE
Understanding the terms used to designate
quantities of wood
29
Combustion chamber lining
Various terms are used to designate quantities of wood. Before you
buy wood, it makes sense to familiarize yourself with these terms.
There are various brochures, in public libraries for example, that
cover this topic.
Slight cracks can appear in the combustion chamber lining due to
moisture or sudden heating/cooling. These cracks have no influence
on the output or lifetime of your stove. However, if the lining starts to
crumble and fall out, you must replace it. The combustion chamber
lining is not covered by the warranty.
Use of the following as fuel is illegal
Seals
Painted, pressure impregnated, or glued wood, or sea driftwood. Nor
should you ever burn chipboard, plastics, or treated paper. These
contain substances which are hazardous to human health, to the
environment, your stove, and your chimney. In short – make sure you
only use proper wood.
All wood-burning stoves have seals made of ceramic material fitted
to the stove, the door and/or the glass. These seals are subject to wear
and tear and must be replaced when necessary.
Seals are not covered by the warranty.
Sweeping the chimney and cleaning your stove
Wood types
Kg Dry wood/m3
Compared to beech
Hornbeam
640
110%
Beech/Oak
580
100%
98%
Follow national and local regulations for sweeping the chimney. We
recommend having the stove cleaned regularly by a chimney sweep.
Before cleaning the stove and sweeping the flue pipe and chimney,
we recommend removing the baffle plates.
Ash
570
Maple
540
93%
Birch
510
88%
Removing the baffle plates
Pine
480
83%
See section “Servicing”.
Fir
390
67%
Poplar
380
65%
Checking the stove
Scan A/S recommends that you check your stove thoroughly after
sweeping/cleaning. Check all visible surfaces for cracks. Check that
all joints are tight and that the gaskets are correctly seated. Worn or
deformed gaskets should be replaced.
Maintaining your wood-burning
stove
Apart from having the chimney swept, your wood-burning stove does
not require any regular maintenance. However, we do recommend
servicing at least once every two years.
Servicing
We recommend that the stove be thoroughly serviced at least once
every two years. The service should include the following:
• Lubricate hinges using copper grease.
Only use original spare parts for maintenance and repair of your
stove.
• Check gaskets. Replace any that are broken or have gone soft.
NB: Make sure the stove is cold before starting maintenance or repair
work.
• Check heat-insulating materials.
• Check the combustion chamber bottom and riddling grate.
The stove must be serviced by a qualified fitter. Only use original
spare parts.
Painted surfaces
Clean your wood-burning stove by wiping it down with a dry, lint-free
cloth.
If the paint finish gets damaged, you can purchase repair paint in
spray form from your Scan dealer. As slight differences in colour
shade are possible, we recommend you spray a larger area to achieve
a natural blend. For best results, apply repair spray when the stove
is warm enough for you to just keep your hand on it, but no hotter.
Cleaning the glass
Our wood-burning stoves are designed to prevent serious soot buildup on the glass. The best way to achieve this is to make sure you have
a good supply of combustion air. It is also very important that the
wood is dry and the chimney correctly dimensioned.
Even if you operate the stove in accordance with our instructions, a
slight film of soot may still accumulate on the glass. You can easily
remove this film by wiping the glass down with a dry cloth and then
with a cloth dampened with glass cleaner. Please note that the glass
cleaner is not to get into contact with the gaskets, as this can discolour the glass permanently.
The detergent must not come into contact with the painted surfaces
as these can be damaged.
Disposal of stove parts
Steel/cast iron: Send for recycling.
Glass: Dispose of as ceramic waste.
Combustion chamber lining: Vermiculite or chamotte is not recyclable. Dispose of as waste.
Baffle plates: Vermiculite or chamotte is not recyclable. Dispose of as
waste.
Gaskets/sealing rope: Dispose of as waste.
MAINTENANCE
30
Removing the baffle plates
Be very careful when removing the baffle plates from the stove.
A
A
Upper baffle plate
Lower baffle plate
Combustion chamber lining
NAVN:
Scan 83
EMNE:
Snit gennem ovn
VÆGT: 339,26
MATERIALE:
DIMENSION:
STI:
TG.NR:
AREAL:
23750265 mm^2
Scan 83
DATO:
25-01-13
BC
Krog Iversen & Co A/S
Upper baffle plate
EMNE:
Holder for
upper
baffle
plate
Snit gennem ovn
VÆGT: 339,26
MATERIALE:
DIMENSION:
SIGN:
DK-5492 Vissenbjerg©
C:\Working Folder\Designs\Scan 83\90583008.idw
NAVN:
kg
90583008
AREAL:
C:\Working Folder\Designs\Scan 83\90583008.idw
kg
23750265 mm^2
DATO:
TG.N
25-01-13
Krog Iversen &
DK-5492 Vissen
EMNE:
31
MAINTENANCE
Lift the lower baffle plate.
Lift the upper baffle plate and remove the pin. Pass the baffle plate
edge-first and downwards out through the combustion chamber.
D
Turn the baffle plate 90°, and lower it out through the combustion
chamber.
D
NAVN:
Scan 85
EMNE:
Stift for øverste røgvenderplade
VÆGT: N/A
MATERIALE:
AREAL:
DIMENSION:
STI:
N/A
Scan 85
EMNE:
VÆGT: N/A
AREAL:
DIMENSION:
Nedre røgvenderplade løftes
19-11-10
Krog Iversen & C
Stift for øverste røgvenderplade
MATERIALE:
STI:
DATO:
DK-5492 Vissenb
I:\Udvikling\TEGNING\Scan85\90585038.idw
NAVN:
TG.NR
I:\Udvikling\TEGNING\Scan85\90585038.idw
TG.NR:
N/A
TG.NR:
DATO:
19-11-10
Krog Iversen & Co
DK-5492 Vissenbj
MAINTENANCE
32
The baffle plate holder may fall out when the baffle plate is taken
out of the stove. See the illustrations below for how to fit it.
Scan 85
NAVN:
EMNE:
Carefully lift the sides and rear plates of the combustion chamber
lining out of the stove.
Øverste røgvenderplade
AREAL:
DIMENSION:
90585039
TG.NR:
VÆGT: N/A
MATERIALE:
STI:
Removing the combustion chamber lining
N/A
DATO:
22-11-10
SIGN:
BC
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
I:\Udvikling\TEGNING\Scan85\90585039.idw
Scan 83
NAVN:
EMNE:
Afmontage brændkammerforing (side)
VÆGT: N/A
MATERIALE:
DIMENSION:
STI:
NAVN:
Scan 85
EMNE:
Øverste røgvenderplade
DIMENSION:
VÆGT: N/A
I:\Udvikling\TEGNING\Scan85\90585039.idw
AREAL:
N/A
C:\Working Folder\Designs\Scan 83\90583035.idw
MATERIALE:
STI:
AREAL:
N/A
TG.NR:
DATO:
22-11-10
90585039
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
BC
TG.NR:
DATO:
05-03-2013
9
SIG
Krog Iversen & Co A
DK-5492 Vissenbjerg
33
TROUBLESHOOTING
Troubleshooting
Smoke escaping
The door does not close
It may occur during transport that the locking device moves out if
its correct position, so that the door does not close properly. This can
easily be adjusted, see below.
• Damp wood
• Chimney not drawing properly
• Chimney is not properly dimensioned for the stove
• Check if the smoke gas pipe/chimney are blocked
1. Remove the cover plate
• Is the chimney the right height for its surroundings?
• At rear outlet, check that the flue pipe does not obstruct the chimney draught
• Vacuum in room
• The door is opened before the embers have burned down
­sufficiently
Wood burning too quickly
• The air valves are set incorrectly
• The baffle plates are incorrectly mounted or missing
• Inferior firewood (waste wood, pallets etc.)
• Chimney too large
2. Locking device
Soot build-up on glass
• Incorrect secondary airflow setting
• Excessive primary air
• Damp wood
÷
• Wood pieces too large on lighting
• Inferior firewood (waste wood, pallets etc.)
• Chimney not drawing sufficiently
• Vacuum in room
Excessive soot build-up in chimney
3. Press the locking device in its correct position
• Poor burning (more air required)
• Damp wood
The surface of the stove is turning grey
• Overheating (see instructions for heating)
Poor heating performance of stove
• Damp wood
• Not enough wood
• Inferior wood quality with low fuel value
• Baffle plates are not fitted correctly
Smell and sound of the stove
• The lacquer on the stove hardens when you use the stove for the
first time; this can cause an odour. Open a window or a door for
ventilation, and make sure the stove is heated up sufficiently to
avoid odours later.
• When heating up and cooling down, the stove may make some
clicking noises. These are due to the huge temperature differences
to which the material is exposed and do not indicate any product
defects.
4. Mount the cover plate
34
WARRANTY
Warranty
All wood-fired Scan products are made of high-quality materials and
subject to strict quality controls before leaving the factory. We give a
warranty of 5 years on manufacturing errors or defects.
You must quote your stove‘s product registration number when you
contact us or your authorised Scan dealer with a warranty claim.
The warranty covers all parts which in the opinion of Scan A/S require
repair or replacement due to manufacturing or construction error
The warranty applies to the original purchaser of the product only,
and is not transferable (except on prior sale).
The warranty covers only damage caused by manufacturing or construction errors.
The following parts are not covered by the
warranty
• Wear and tear parts, such as the combustion chamber liners, baffle plates, riddling grate, glass, and seals (except for defects which
were present on delivery).
• Defects caused by external chemical and physical influences
during transportation, storage and assembly, or at a later time.
• Soot build-up caused by poor chimney draught, damp wood, or
improper use.
• Costs of additional heating in connection with a repair.
• Transport costs.
• Costs for setting up, removing the wood stove.
This warranty is void
• In case of incorrect installation (the installer is responsible for
observing and complying with legal requirements and local bylaws,
along with this Assembly- and Instructionsmanual for the woodburning stove and accessories).
• In case of improper use, and/or use of prohibited fuels, non-original spares (see this Assembly- and instructions manual).
• If the product registration number of the stove has been removed
or damaged.
• In case of repairs that do not comply with our instructions or
instructions by an authorised Scan dealer.
• In case of any manipulation of the original state of this Scan product or its accessories.
• This warranty is only valid in the country to which this Scan product was originally supplied.
Always use original replacement parts, or parts recommended by
the manufacturer.
35
Own comments
36
Version:
UK 90583500
01.01.2018
Scan A/S - DK-5492 Vissenbjerg
Download PDF
Similar pages