PRODUCT RANGE 08 WATER CHILLERS HEAT PUMPS FAN COIL UNITS AIR HANDLING UNITS Rhoss takes part in the Eurovent certification programme. Concerned products are included in the guide to Eurovent certified products, which can be consulted at www.eurovent-certification.com Residential Hotels Airports Offices Meeting & Congress Rooms Industrial Processes Shopping Centres Health Care P.3 Rhoss: your partner in innovation Since 1968, Rhoss has been a guarantee for innovation, quality and top level service. This is what makes us the ideal partner for the most demanding companies. Our know-how, born from 40 years’ experience, enables us to meet innumerable requirements while adhering to the new technological and design trends of the HVAC sector. In all these years, we at Rhoss have constantly evolved to the point of specialising in the manufacture of units for residential and industrial air conditioning. Our evolution has followed market development and customers' needs providing state-of-the-art products which are both highly efficient and environmentally friendly. In particular, technological innovation is the driving force behind the development of our new products and is guaranteed by R&D Lab, the state-of-the-art trial and testing laboratory. This is where research is carried out in conjunction with the most prestigious university institutes and the products are certified according to Eurovent regulations. Thanks to these strong points Rhoss is and will be your ideal partner. P.5 Guarantee of quality, certainty of service. The reliability of our products is ensured by constant trials and demanding functional tests that allow us to maintain the highest standards of quality. All this is proven by Vision 2000 certification and by participation in the Eurovent programme which attests the performance of our products. In our search for continuous improvement we have always dedicated great effort and strong investments, like the implementation of the Lean manufacturing philosophy in the company's organisation which makes us even more competitive and more rapid in our response to customers. Ultimately, certainty of service has always been one of our primary objectives: through Rhoss Smile Service product assistance is guaranteed, thanks to highly specialised technicians who are focused on customers' needs. Wherever you breathe clean conditioned air through safe advanced systems, Rhoss is there. P.7 Adaptive Function Plus: the revolution in low consumption Continuous research and testing, combined with a deep knowledge in air conditioning, has assisted our designer staff in creating Adaptive Function Plus, an innovative technology developed to reduce energy consumption. Adaptive Function Plus is an exclusive patent by Rhoss born of the partnership with the University of Padua and applied to the new ranges of water chillers and heat pumps. Quality of life and care for the environment thus take shape through a project aimed at the well-being of the individual, without neglecting the planet where we live. PRODUCT RANGE WATER CHILLERS - HEAT PUMPS Air cooled - Axial fans TCAEY-THAEY 105÷111 Mini-Y Range Hermetic rotary Scroll compressors P.14 Microsystem 15,4÷32,5 kW 16,8÷37,5 kW P.18 P.22 Y-Mich Range Hermetic rotary Scroll compressors P.26 Macrosystem 68,2÷316,2 kW 76,7÷356,2 kW P.30 Y-Power Range Hermetic rotary Scroll compressors P.34 P.32 Q-Power Range Semi-hermetic screw compressors TCAVZ 2310÷2670 P.36 Z-Power Range Semi-hermetic screw compressors Z-Power Range Semi-hermetic screw compressors Macrosystem 297,5÷665,9 kW Macrosystem 324,8÷693,2 kW Macrosystem 764,5÷1.283,4 kW TCAV 1280÷2450 Macrosystem 264,05÷445,50 kW Macrosystem 331,4÷455,1 kW 353,4÷486,2 kW Z-Power Range Semi-hermetic screw compressors TCAE-THAE 270÷2160/4155÷4320 P.28 Q-Pack Range Hermetic rotary Scroll compressors Macrosystem 138÷325 kW 159,6÷342 kW TCAVZ 2770÷21290 H.E. P.24 Macrosystem 67÷161 kW 79÷175 kW Y-Pack Range Hermetic rotary Scroll compressors TCAVZ 2330÷2700 H.E. TCAEY-THAEY 270÷2160 Y-Pack Range Hermetic rotary Scroll compressors Microsystem 23,8-48,1 kW 27,3-52,9 kW TCAEY-THAEY 5350÷6450 P.20 Microsystem 44,2÷64 kW 47,8÷67,9 kW Microsystem 13,4÷27,8 kW 15,6÷31,7 kW TCAEY-THAEY 4160÷4320 TCAEY-THAEY 245÷265 Compact-Y Range Hermetic rotary Scroll compressors Compact-Y Range Hermetic rotary Scroll compressors TCAIY-THAIY 124-150 P.16 Compact-Y Range Hermetic rotary Scroll compressors Microsystem 5,5÷11,1 kW 5,8÷12,4 kW TCAEY-THAEY 118÷136 H.E. TCAEY-THAEY 115÷233 P.38 TCAVZ 2750÷21250 Z-Power Range Semi-hermetic screw compressors Macrosystem 732÷1.251,5 kW P.40 Radiant Systems Air-cooled - Centrifugal fans TCCEY-THCEY 105÷111 P.42 Mini-Y Range Hermetic rotary Scroll compressors Microsystem 7,5÷14,8 kW 6,0÷12,6 kW P.44 Compact Range Hermetic rotary Scroll compressors TCAEY-THAEY 118÷136 H.E. P.18 Compact-Y Range Hermetic rotary Scroll compressors Microsystem 13,5÷22 kW 13,6÷24 kW TCCE-TCPE-THCE-THPE 130÷270 P.14 Mini-Y Range Hermetic rotary Scroll compressors Microsystem 4,8÷10,4 kW 5÷11 kW TCCE-THCE 114÷126 TCAEY-THAEY 105÷111 Microsystem 17,4÷36,5 kW 15,8÷32,4 kW P.46 TCHEY-THHEY 105÷112 Comby-Flow Range Hermetic rotary Scroll compressors Hermetic rotary Scroll compressors Macrosystem 30,1÷66,3 kW 34,9÷77,1 kW P.48 Microsystem 7,6÷16,5 kW 6,9÷14,8 kW Water-cooled - Condenserless units TCHEY-THHEY 105÷112 Comby-Flow Range Hermetic rotary Scroll compressors P.48 Microsystem 5,4÷12 kW 6,5÷13,9 kW TCHE-THHE 280÷4260 P.50 Mini-Q Flow / Compact Flow Range Hermetic rotary Scroll compressors 12,3÷63,6 kW 15,2÷72,4 kW P.52 Q-Flow Range Hermetic rotary Scroll compressors TCHVZ 1200÷31630 P.54 Z-Flow Range Semi-hermetic screw compressors Macrosystem 76,5÷255,3 kW 86,6÷289,9 kW TCEE 105÷165 TCHE-THHE 115÷165 Macrosystem 199,7÷1.629,2 kW P.56 TCEE 280÷4260 P.58 Q-Flow E Range Hermetic rotary Scroll compressors Mini-Q Flow E / Compact Flow E Range Hermetic rotary Scroll compressors Macrosystem 74,2÷249 kW 5,5÷62,2 kW TCEVZ 1200÷31630 P.60 Z-Flow E Range Semi-hermetic screw compressors Macrosystem 171,9÷1.424,8 kW EXP - Polyvalent system TXAEY 117÷133 P.64 Compact-Y EXP Range Hermetic rotary Scroll compressors Microsystem 42,6÷61,9 kW 47,8÷67,9 kW P.68 Q-Pack EXP Range Hermetic rotary Scroll compressors Condensing units Hermetic rotary blade and Scroll compressors Microsystem 5,1÷26,3 kW 6÷29,9 kW TXHEY 105÷112 Comby-Flow EXP Range Hermetic rotary Scroll compressors Microsystem 5,4÷12 kW 6,5÷14,5 kW Macrosystem 70,4÷307,1 kW 75,5÷357,3 kW MCAE-MHAE 105÷127 P.66 Compact-Y EXP Range Hermetic rotary Scroll compressors Microsystem 17,4÷34 kW 17,9÷39,1 kW TXAE 475÷4315 TXAEY 245÷265 P.72 P.70 SYSTEM ACCESSORIES P.74 CCAM 105÷2130 CEHV-CEHP 46÷2791 Remote condensers Cooling towers Axial fans Axial fans P.78 AS 0300÷2500 Pumping group PBHI 0200-0400 P.76 P.80 Pumping group Macrosystem 50,2÷249 kW FAN COIL UNITS - TERMINAL UNITS IDROWALL P.82 FREND Wall-mounted fan coil units Floor and ceiling fan coil units Tangential fans Tangential fans Unit-System 1,3÷2,5 kW 3,2÷5,4 kW Unit-System 1÷2,9 kW 2,2÷5,7 kW BRIOEV P.86 YARDYEV Floor and ceiling fan coil units Floor and ceiling fan coil units Centrifugal fans Centrifugal fans Unit-System 1÷6,9 kW 2,2÷16,5 kW P.91 Recessed fan coil units for vertical and horizontal installation Centrifugal fans YARDYEV P.91 Ductable fan coil units for horizontal installation Centrifugal fans Unit-System 1,1÷7,2 kW 2,4÷17,4 kW Unit-System 3,5÷6,2 kW 7,6÷13,6 kW UTNC-EV P.94 VTNC P.96 Cassette-type fan coil units Cassette-type fan coil units Unit-System 2,5÷8,5 kW 5,4÷20,4 kW Unit-System 2,4÷10 kW 5,4÷23,6 kW UTNB 011÷017 P.98 Ductable terminal air handling units in sections Air flow rate: 1.100÷1.680 m3/h UTNA 015÷150 P.100 Ductable terminal air handling units in sections Air flow rate: 1.800÷16.500 m3/h Unit-System 4,1÷10,5 kW 10,3÷23 kW Unit-System 7,2÷108 kW 11,3÷174 kW UTNV 030÷150 P.102 Air conditioning and ventilation terminal units Air flow rate: 3.150÷15.600 m3/h UTNR 012÷041 Air renewal terminal units with heat recovery Air flow rate: 3.150÷15.600 m3/h Unit-System 14,5÷98,2 kW 22,3÷226,8 kW Unit-System 5,4÷18,6 kW P.106 CONTROLS for fan coil units and terminal units AIR HANDLING UNITS Advance Range Air handling units Air flow rate:: 850÷140.000 m3/h P.89 Unit-System 1,1÷7,2 kW 2,4÷17,4 kW YARDYEV CTA ADV 240÷22920 P.84 P.112 P.104 INTEGRATED SOLUTIONS FOR SYSTEM MANAGEMENT home office P.108 Price list range: Microsystem hotel iDRHOSS is an advanced system for the management of hydronic air conditioning systems, developed to meet the Unit-System comfort needs of any civil or residential location. Macrosystem P.110 SUPERVISION SOFTWARE Refrigerant gases: RHOSS SUPERVISOR is the Rhoss supervision system that allows monitoring and remote management of Rhoss units used in a hydronic system. PACKAGED DE-HUMIDIFIERS FOR POOLS DRESY - DAESY 108÷2111 Meaning of symbols: Cooling only Heat pump Outdoor installation Indoor installation Non-ductable unit Ductable unit P.116 Dry Pool ADV range Dehumidification capacity: 8÷111 l/h WATER CHILLERS HEAT PUMPS P. 14 SYSTEM ACCESSORIES P. 74 FAN COIL UNITS P. 82 TERMINAL UNITS P. 98 CONTROLS P. 106 iDRHOSS P. 108 SUPERVISION SOFTWARE P. 110 AIR HANDLING UNITS P. 112 TCAEY-THAEY 105÷111 Mini-Y Range Fan coil systems Radiant Systems Packaged air-cooled reversible water chillers and heat pumps with axial fans. Range with hermetic Scroll compressors and R410A refrigerant gas. Construction features Compressor: hermetic, rotary Scroll compressor, complete with thermal protection. Water side heat exchanger: adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water flow differential pressure switch Air side heat exchanger: finned coil exchanger, with copper pipes and aluminium fins or coil with aluminium micro-channel pipes, complete with protection grille. Fan: axial fan with external rotor, equipped with internal thermal protection and complete with protection grille. Control: microprocessor electronic control available in 2 versions: Standard, with Adaptive Function logic, and iDRHOSS compatible, with Adaptive Function Plus logic Structure: in galvanised and painted sheet steel, complete with condensation drain pan for THAEY. Models TCAEY: unit designed for cooling only. THAEY: heat pump unit. PUMP unit • With standard pump. • With high-pressure pump. Pumping group complete with: standard or high-pressure circulation pump for models 105÷107 only, expansion tank with membrane, manual air bleed valve and safety valve. TANK & PUMP unit • With standard pump. • With high-pressure pump. Pumping group complete with: water buffer tank, standard or high-pressure circulation pump for models 105÷107 only, expansion tank with membrane, manual air bleed valve, automatic air bleed valve and safety valve. Factory fitted accessories • Soft-start device (for models with power supply 230 V). • -10°C condensation control. • Low pressure switch. • Compressor heater. • Unit base antifreeze electric heater for operation in heat pump mode at external air temperature of below –5°C. Option with control • Digital input for double set-point • 4-20 mA analogue input for shifting set-point. Accessories supplied loose • Antivibration rubber mountings • -10°C condensation control. • Water filter • Low pressure switch. • Antifreeze electric heater on the buffer tank • Remote keyboard with display. • Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). • Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. Option with control • Clock card • Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. • GSM 900/1800 modem kit for remote unit management. • Rhoss supervision system for unit monitoring and remote management. P. 15 Microsystem 5,5÷11,1 kW 5,8÷12,4 kW PUMP unit Expansion tank H Circulation pump L 105 107 109 111 5,5 6,9 8,8 10,8 / 11,1 ❶ E.E.R. 2,74 2,58 2,66 2,62 / 2,62 ● E.S.E.E.R. 3,15 2,77 3,16 3,11 / 3,15 TCAEY-THAEY MODEL ❶ Nominal cooling capacity kW ❶ Absorbed power (*) kW 2,00 2,67 3,32 4,12 / 4,25 ➋ Nominal heating capacity kW 5,8 7,5 9,7 12,0 / 12,4 2,74 2,71 2,83 2,72 / 2,78 2,13 2,77 3,41 4,42 / 4,42 14,5 / 14,8 ➋ C.O.P. ➋ Absorbed power (*) kW ❸ Cooling capacity (radiating) kW ❸ E.E.R. (radiating) 7,5 8,9 12,1 3,71 3,27 3,53 3,20 / 3,27 2,72 3,43 4,53 / 4,53 12,2 / 12,6 ❸ Absorbed power (radiating) (*) kW 2,02 ❹ Heating capacity (radiating) kW 6,00 7,90 9,90 3,70 3,91 3,76 3,66 / 3,77 1,62 2,02 2,63 3,33 / 3,34 ❹ C.O.P. (radiating) ❹ Absorbed power (radiating) (*) kW ➎ Sound pressure level dB(A) Scroll/step compressor No. Circuits No. Water tank content l ❶ Available head pressure of pump kPa Main supply V-ph-Hz 46 47 47 47 1/1 1/1 1/1 1/1 1 1 1 1 19 19 30 30 55 55 85 75 230-1-50 230-1-50 / 400-3+N-50 230-1-50 / 400-3+N-50 230-1-50 / 400-3+N-50 105 107 109 111 L - Width mm 990 990 990 990 H - Height PUMP mm 905 905 1.085 1.085 H - Height TANK & PUMP mm 905 905 1.295 1.295 P - Depth mm 380 380 380 380 ➏ Weight TCAEY kg 131 133 157 166 ➏ Weight THAEY kg 141 143 167 176 DIMENSIONS AND WEIGHTS In the following conditions: ❶ Air: 35°C - Water: 7/12°C ➋ Air: 7°C D.B. - 6°C W.B. - Water: 45/40°C. ❸ Air: 35°C - Water: 18/23°C - ❹ Air: 7°C D.B. - 6°C W.B. - Water 35/30°C ➎ At 5 m from the unit, coil side, in free field (Q = 2). ➏ The weight refers to the unit in its most complete form ● ESEER (European Seasonal EER) - European seasonal average efficiency (*) Unit without pump WATER CHILLERS - HEAT PUMPS P TCAEY-THAEY 115÷233 Compact-Y Range Packaged air-cooled reversible water chillers and heat pumps with axial fans. Range with hermetic Scroll compressors and R410A refrigerant gas. TANK & PUMP unit Construction features Factory fitted accessories Compressor: hermetic, rotary Scroll compressor, complete with thermal protection and crankcase heater for mod. 127÷233. Water side heat exchanger: adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water flow differential pressure switch. Air side heat exchanger: finned coil exchanger, with copper pipes and aluminium fins. Fan: axial fan with external rotor, equipped with internal thermal protection and complete with protection grille. Control: microprocessor electronic control available in 2 versions: Standard, with Adaptive Function logic, and iDRHOSS compatible, with Adaptive Function Plus logic. Structure: in galvanized and painted sheet steel, complete with condensation drain pan. Models TCAEY: unit designed for cooling only. THAEY: heat pump unit. STANDARD unit (for mod. 133-233 only) Without pumping group and buffer tank. PUMP unit Pumping group complete with: circulation pump, expansion tank with membrane, manual air bleed valve, safety valve and pressure gauge. Pumping group complete with: water buffer tank, circulation pump, expansion tank with membrane, manual air bleed valve, automatic air bleed valve, safety valve and pressure gauge. • -10°C condensation control. • Antifreeze electric heater on the buffer tank. • Crankcase heater compressor (mod. 115÷124). • Protection coil grilles. • Desuperheater 15% (mod. 133-233). • 100% heat recovery (mod. 133-233). • Single pump with increased head pressure (mod. 133-233). • Single pump with increased head pressure + buffer (mod. 133-233). Option with control • Digital input for double set-point • 4-20 mA analogue input for shifting set-point. Accessories supplied loose • Protection coil grilles. • Antivibration rubber mountings. • -10°C condensation control. • Remote keyboard with display. • Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). • Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. Option with control • Clock card • Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. • GSM 900/1800 modem kit for remote unit management. • Rhoss supervision system for unit monitoring and remote management. P. 17 Microsystem 15,4÷32,5 kW 16,8÷37,5 kW TCAEY-THAEY MODEL ❶ Nominal cooling capacity kW 115 117 122 124 127 130 133 233 15,4 17,4 22,7 24,3 26,9 29,1 34,0 32,5 ❶ E.E.R. 2,76 2,67 2,76 2,62 2,59 2,44 2,56 2,64 ● E.S.E.E.R. 3,15 3,11 3,44 3,09 3,18 2,89 2,85 2,92 12,3 ❶ Absorbed power (*) kW 5,6 6,5 8,2 9,3 10,4 11,9 13,3 ➋ Nominal heating capacity kW 16,8 17,9 23,9 26,1 30,7 34,4 39,1 37,5 3,05 2,94 3,02 2,92 3,07 3,10 2,94 3,05 12,3 ➋ C.O.P. ➋ Absorbed power (*) kW 5,5 6,1 7,9 8,9 10,0 11,1 13,3 ❸ Sound pressure level dB(A) 50 50 52 52 53 54 55 55 Scroll/step compressor No. 1/1 1/1 1/1 1/1 1/1 1/1 1/1 2/2 Circuits No. Water tank content l ❶ Available head pressure of standard pump kPa Main supply V-ph-Hz 1 1 1 1 1 1 1 1 35 35 45 45 45 45 80 80 147 130 130 125 110 105 134 134 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 In the following conditions: ❶ Air: 35°C - Water: 7/12°C ❷ Air: 7°C D.B. - 6°C W.B. - Water: 45/40°C. ❸ At 5 m from the unit in free field (Q = 2). ● ESEER (European Seasonal EER) - European seasonal average efficiency 115 117 122 124 127 130 133 233 L - Width STANDARD mm – – – – – – 1660 1660 L - Width PUMP mm 1230 1230 1230 1230 1535 1535 1660 1660 L - Width TANK & PUMP mm 1522 1522 1522 1522 1822 1822 1660 1660 H - Height mm 1090 1090 1280 1280 1510 1510 1570 1570 P - Depth mm 580 580 600 600 695 695 1000 1000 ❹ Weight TCAEY kg 210 220 270 280 310 370 450 465 ❹ Weight THAEY kg 215 225 278 288 320 380 460 475 DIMENSIONS AND WEIGHTS ❹ The weight refers to the unit in its most complete form WATER CHILLERS - HEAT PUMPS (*) Unit without pump TCAEY-THAEY 118÷136 H.E. Compact-Y Range Radiant Systems Fan coil systems C.O.P. > 3.8 High energy efficiency packaged air-cooled reversible water chillers and heat pumps with axial fans. Range with hermetic Scroll compressors and R410A refrigerant gas. Construction features Compressor: hermetic, rotary Scroll compressor, complete with thermal protection and crankcase heater. Water side heat exchanger: adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water flow differential pressure switch. Air side heat exchanger: finned coil exchanger, with copper pipes and aluminium fins. Fan: axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous fan rotation speed regulation. Control: microprocessor electronic control, iDRHOSS compatible, with Adaptive Function Plus logic. Structure: in galvanized and painted sheet steel, complete with condensation drain pan for THAEY. Models TCAEY: unit designed for cooling only. THAEY: heat pump unit. PUMP unit Pumping group complete with: standard circulation pump, expansion tank with membrane, manual air bleed valve, safety valve and gauge. TANK & PUMP unit • With tank and pump • With tank, pump and water bypass between primary and secondary circuit Pumping group complete with: circulation pump and water buffer tank or circulation pump, water buffer tank and water bypass which disconnects the primary from the secondary water circuit, expansion tank with membrane, manual air bleed valve, automatic air bleed valve, safety valve and pressure gauge. Factory fitted accessories • Antifreeze electric heater on the buffer tank. • Protection coil grilles • Unit base antifreeze electric heater for operation in heat pump mode at external air temperature of below –5°C. • Digital input for double set-point • 4-20 mA analogue input for shifting set-point. Accessories supplied loose • Protection coil grilles • Antivibration rubber mountings. • Remote keyboard with display. • Clock card • Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). • Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. • Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. • GSM 900/1800 modem kit for remote unit management. • Rhoss supervision system for unit monitoring and remote management. P. 19 Microsystem 13,4÷27,8 kW 15,6÷31,7 kW TCAEY-THAEY H.E. MODEL ❶ Nominal cooling capacity (radiating) kW ❶ E.E.R. (radiating) ❶ Absorbed power (radiating) (*) kW ➋ Nominal heating capacity (radiating) kW ➋ C.O.P. (radiating) 118 120 125 129 132 136 17,4 20,1 24,6 28,9 31,5 36,5 3,13 3,16 3,33 3,27 3,37 3,19 5,57 6,35 7,39 8,85 9,36 11,46 15,8 16,2 20,4 23,9 28,2 32,4 3,94 3,89 4,19 4,02 4,08 3,96 ➋ Absorbed power (radiating) (*) kW 4,01 4,16 4,87 5,94 6,91 8,18 ❸ Cooling capacity kW 13,4 15,5 18,7 22,6 24,3 27,8 ❸ E.E.R. 2,70 2,92 2,97 2,97 2,96 2,74 ● E.S.E.E.R. 3,48 3,51 3,45 3,42 3,58 3,31 10,12 ❸ Absorbed power (*) kW 4,95 5,33 6,30 7,61 8,20 ❹ Heating capacity kW 15,6 16,1 20,3 23,8 27,7 31,7 3,14 3,09 3,32 3,19 3,20 3,13 4,97 5,23 6,10 7,48 8,63 10,12 48 50 52 52 53 54 1/1 1/1 1/1 1/1 1/1 1/1 ❹ C.O.P. ❹ Absorbed power kW ➎ Sound pressure level dB(A) Scroll/step compressor No. Circuits No. Water tank content l ❶ Available head pressure of pump T kPa Main supply V-ph-Hz 1 1 1 1 1 1 35 35 45 45 45 45 129 108 116 98 95 81 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 In the following conditions: ❶ Air: 35°C - Water: 18/23°C ❷ Air: 7°C D.B. - 6°C W.B. - Water 35/30°C ❸ Air: 35°C - Water: 7/12°C - ❹ Air: 7°C D.B. - 6°C W.B. - Water: 45/40°C. ➎ At 5 m from the unit, coil side, in free field (Q = 2). ● ESEER (European Seasonal EER) - European seasonal average efficiency 118 DIMENSIONS AND WEIGHTS 120 125 129 132 136 1.230 1.230 1.230 1.535 1.535 1.522 1.522 1.822 1.822 1.280 1.280 1.510 1.510 600 600 695 695 220 270 280 310 370 225 278 288 320 380 L - Width PUMP mm 1.230 L - Width TANK & PUMP mm 1.522 1.522 H - Height mm 1.090 1.090 P - Depth mm 580 580 ➏ Weight TCAEY kg 210 ➏ Weight THAEY kg 215 ➏ The weight refers to the unit in its most complete form WATER CHILLERS - HEAT PUMPS (*) Unit without pump TCAEY-THAEY 245÷265 Compact-Y Range 3 capacity steps Packaged air-cooled reversible water chillers and heat pumps with axial fans. Range with hermetic Scroll compressors and R410A refrigerant gas. Construction features Compressor: hermetic, rotary Scroll compressor, complete with thermal protection and crankcase heater. 3 capacity steps with high efficiency at partial loads. Water side heat exchanger: adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water flow differential pressure switch. Air side heat exchanger: finned coil exchanger, with copper pipes and aluminium fins. Fan: axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous fan rotation speed regulation. Control: microprocessor electronic control, iDRHOSS compatible, with Adaptive Function Plus logic. Structure: in galvanized and painted sheet steel, complete with condensation drain pan for THAEY. Models TCAEY: unit designed for cooling only. THAEY: heat pump unit. Factory fitted accessories • PUMP with single or double pump, including an automatic pump in standby, complete with expansion tank, air bleed valve, safety valve and water pressure gauge. The pumps are available in the low or high pressure versions. • TANK&PUMP with water buffer tank and single or double pump, including an automatic pump in standby, complete with expansion tank, air bleed valve, safety valve and water pressure gauge. The pumps are available in the low or high pressure versions. • 15% desuperheater. • 100% heat recovery. • Refrigerant circuit high and low pressure gauges. • Protection coil grilles. • Antifreeze electric heater for buffer tank and pumps. • Digital input for double set-point • 4-20 mA analogue input for shifting set-point. Accessories supplied loose • Protection coil grilles • Antivibration rubber mountings. • Remote keyboard with display. • Clock card • Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). • Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. • Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. • GSM 900/1800 modem kit for remote unit management. • Rhoss supervision system for unit monitoring and remote management. P. 21 Microsystem 44,2÷64,0 kW 47,8÷67,9 kW TCAEY-THAEY MODEL 245 250 260 265 44,2 51,3 59,2 64,0 ❶ E.E.R. 2,55 2,60 2,68 2,67 ● E.S.E.E.R. 3,78 4,31 4,38 4,03 24,0 ❶ Nominal cooling capacity kW ❶ Absorbed power (*) kW 17,4 19,7 22,1 ➋ Nominal heating capacity kW 47,8 55,8 62,2 67,9 2,89 3,00 3,04 2,91 16,6 18,6 20,5 23,3 56 56 57 57 2/3 2/3 2/3 2/3 ➋ C.O.P. ➋ Absorbed power (*) kW ❸ Sound pressure level dB(A) Scroll/step compressor No. Circuits No. Main supply V-ph-Hz 1 1 1 1 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 DIMENSIONS AND WEIGHTS L - Width mm 245 250 260 265 2.260 2.260 2.260 2.260 H - Height mm 1.570 1.570 1.570 1.570 P - Depth mm 1.000 1.000 1.000 1.000 ❹ Weight TCAEY kg 725 750 775 820 ❹ Weight THAEY kg 745 770 795 840 In the following conditions: ❶ Air: 35°C - Water: 7/12°C ❷ Air: 7°C D.B. - 6°C W.B. - Water: 45/40°C. ❸ At 5 m from the unit in free field (Q = 2). ❹ The weight refers to the unit in its most complete form ● ESEER (European Seasonal EER) - European seasonal average efficiency H (*) Unit without pump P TANK & PUMP TCAEY-THAEY MODEL Nominal flow l/h Water tank content l 245 250 260 265 7.600 8.800 10.200 11.000 150 150 150 150 Pump available head pressure Pump P1 KPa 113 103 88 75 Pump P2 KPa 186 179 169 150 PUMP TCAEY-THAEY MODEL Nominal flow l/h 245 250 260 265 7.600 8.800 10.200 11.000 Pump available head pressure Pump P1 KPa 122 114 102 92 Pump P2 KPa 195 190 184 167 WATER CHILLERS - HEAT PUMPS L TCAIY-THAIY 124-150 Y-Mich Range Modulating cooling capacity range: 39-100% E.S.E.E.R. > 3,9 Packaged air-cooled reversible water chillers and heat pumps with axial fans. Range with hermetic Scroll Inverter compressors. Construction features Compressor:hermetic, rotary Scroll compressor, complete with thermal protection and crankcase heater, activated by Inverter. Expansion valve: electronic. Water side heat exchanger: stainless steel plate exchanger closed cell polyurethane foam rubber insulation, complete with antifreeze heater and water flow differential pressure switch. Air side heat exchanger: featuring finned coil with copper pipes and aluminium fins, complete with protection grille (model 150 only). Fan: axial fan with external rotor, equipped with internal thermal protection and complete with protection grille and modulating speed control. Control: microprocessor electronic control, iDRHOSS compatible Structure: in galvanized and painted sheet steel (model 124) or in peraluman (model 150), complete with condensation drain pan for THAIY. PUMP unit • With pump • With pump and pump in standby (model 150 only) Pumping group complete with: single or double circulation pump, including one standby pump that is automatically activated in the event of an alarm (model 150 only), expansion tank with membrane, manual air bleed valve, safety valve, water drain tap and pressure gauge. TANK & PUMP unit • With tank and pump. • With tank, pump and pump in standby (model 150 only) Pumping group complete with: water buffer tank complete with antifreeze electric heater (model 150 only), single or double pump, including a pump in standby which is automatically activated in the event of an alarm (model 150 only), expansion tank with membrane, manual air bleed valve, safety valve, water drain valve and pressure gauge. Factory fitted accessories • • • • Buffer tank antifreeze electric heater (for mod. 124 only). Protection coil grilles (for mod. 124 only). Digital input for double set-point 4-20 mA analogue input for shifting set-point. Models Accessories supplied loose TCAIY: unit designed for cooling only. THAIY: heat pump unit. • • • • • STANDARD unit Without pumping group and buffer tank (for model 150 only). • • • • Protection coil grilles (for mod. 124 only). Antivibration rubber mountings. Remote keyboard with display. Clock card Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. GSM 900/1800 modem kit for remote unit management. Rhoss supervision system for unit monitoring and remote management. P. 23 TCAIY - THAIY MODEL ❶ Nominal cooling capacity 124(**) 150 23,8 48,1 I NARY Microsystem 23,8-48,1 kW 27,3-52,9 kW 2,63 kW ❶ E.E.R. 2,53 ● E.S.E.E.R. 3,96 4,10 9,42 18,3 ❶ Absorbed power (*) kW ➋ Nominal heating capacity kW ➋ Absorbed power (*) kW ❸ Sound pressure level dB(A) Water tank content l ❶ Available head pressure of pump T kPa Inverter scroll compressor No. Modulating cooling capacity range Circuits No. Main supply V-ph-Hz 27,3 52,9 2,95 3,05 9,28 17,35 PR E LI M ➋ C.O.P. Refrigerant 52 58 45 150 125 198 1 1 39-100% 39-100% 1 1 400-3+N-50 400-3+N-50 R410A R407C In the following conditions: ❶ Air: 35°C - Water: 7/12°C ❷ Air: 7°C D.B. - 6°C W.B. - Water: 45°/40°C ❸ At 5 m from the unit in free field (Q = 2). ● ESEER (European Seasonal EER) - European seasonal average efficiency 124 150 mm 1522 2.270 H - Height mm 1280 1.650 P - Depth mm 600 968 Weight TCAIY kg 330 550 Weight THAIY kg 338 566 DIMENSIONS AND WEIGHTS L - Width H L P WATER CHILLERS - HEAT PUMPS (*) Unit without pump (**) Available from April 2008 TCAEY-THAEY 270÷2160 Y-Pack Range 3 capacity steps Packaged air-cooled reversible water chillers and heat pumps with axial fans. Range with hermetic Scroll compressors and R410A refrigerant gas. Construction features Compressor: hermetic, rotary Scroll compressor, complete with thermal protection and crankcase heater. 2 or 3 capacity steps depending on the models with high efficiency at partial loads. Water side heat exchanger: stainless steel plate exchanger, complete with closed cell polyurethane foam rubber insulation and water flow differential pressure switch. Air side heat exchanger: finned coil exchanger, with copper pipes and aluminium fins. Fan: axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous regulation of fan rotation speed (TCAEBY excluded). Control: microprocessor electronic control iDRHOSS compatible, with Adaptive Function Plus logic for connection with the main BMS on the market (MODBUS RTU, LON). Structure: load-bearing structure in galvanised and painted sheet steel with polyester powder coating. The unit is also complete with: • Unit with compressor and fan thermal overload switches. Versions • B - Standard version (TCAEBY). • T - High temperature/efficiency version with larger coil surface (TCAETY-THAETY). • S - Silenced version complete with soundproofed compressor compartment, lower fan speed and larger coil surface (TCAESY-THAESY). • Q - Supersilenced version complete with soundproofed compressor compartment, super-low fan speed and larger coil surface (TCAEQY). Models TCAEBY: standard unit designed for cooling only. TCAETY: high temperature/efficiency unit designed for cooling only. TCAESY: silenced unit designed for cooling only. TCAEQY: supersilenced unit designed for cooling only. THAETY: heat pump unit. THAESY: silenced heat pump unit. Factory fitted accessories • PUMP with single or double pump, including an automatic pump in standby, complete with expansion tank, safety valve and water pressure gauge. The pumps are available in the low or high pressure versions. • TANK&PUMP with built-in buffer tank from 250 to 450 litres and single or double pump, complete with expansion tank, air bleed valves, safety valve and water pressure gauge. • Desuperheater. • 100% heat recovery. • Electronic expansion valve • -10°C condensation control (TCAEBY only). • Power factor correction capacitors (cosφ > 0.91). • Soft starter. • Refrigerant circuit high and low pressure gauges. • Metal filters or coil protection grilles. • Unit with copper/copper, copper/tin-plated copper or copper/pre-painted aluminium coils. • Digital input for double set-point • 4-20 mA analogue input for shifting set-point. • Evaporator antifreeze heater, buffer tank, pumps and heat exchangers for heat recovery if present. • Serial interface for connection with external BMS. Accessories supplied loose • Antivibration rubber mountings. • Remote keyboard with display. • Clock card • GSM 900/1800 modem kit for remote unit management. • Rhoss supervision system for unit monitoring and remote management. P. 25 TCAEBY MODEL ❶ Nominal cooling capacity kW ❶ E.E.R. ❶ Absorbed power kW TCAETY-TCAESY-TCAEQY MODEL ❶ Nominal cooling capacity kW ❶ Nominal cooling capacity kW ❶ Nominal cooling capacity kW ❶ E.E.R. ❶ E.E.R. ❶ E.E.R. ● E.S.E.E.R. ❶ Absorbed power kW ❶ Absorbed power kW ❶ Absorbed power kW THAETY-THAESY MODEL ➋ Nominal heating capacity kW ➋ Nominal heating capacity kW ➋ C.O.P. ➋ C.O.P. ❶ Nominal cooling capacity kW ❶ Nominal cooling capacity kW ➋ Absorbed power kW ➋ Absorbed power kW TCAEY-THAEY MODEL ❸ Sound pressure level TCAEBY dB(A) ❸ Sound pressure level TCAETY-THAETY dB(A) ❸ Sound pressure level TCAESY-THAESYdB(A) ❸ Sound pressure level TCAEQY dB(A) ❹ Sound power level TCAEBY dB(A) ❹ Sound power level TCAETY-THAETY dB(A) ❹ Sound power level TCAESY-THAESY dB(A) ❹ Sound power level TCAEQY dB(A) Scroll/step compressor No. Circuits No. Main supply V-ph-Hz DIMENSIONS AND WEIGHTS L - Width version B mm L - Width version T - S - Q mm H - Height version B mm H - Height version T - S - Q mm P - Depth version B mm P - Depth version T - S - Q mm kg ➎ Weight TCAEBY ➎ Weight TCAETY-TCAESY-TCAEQY kg ➎ Weight THAETY-THAESY kg 270 67,5 2,65 25,5 270 70,3 70,3 67,0 2,98 2,98 2,70 4,32 23,6 23,6 24,8 270 79,0 79,0 3,36 3,36 69,4 69,4 23,5 23,5 270 60 55 53 51 82 76 74 72 2/3 1 280 75,3 2,69 28,0 280 79,5 79,5 75,0 2,99 2,99 2,85 4,37 26,6 26,6 26,3 280 86,0 86,0 3,44 3,44 77,7 77,7 25,0 25,0 280 60 56 54 52 82 77 75 73 2/2 1 270 2.650 3.150 1.700 1.520 1.210 1.210 685 745 810 280 2.650 3.150 1.700 1.520 1.210 1.210 725 765 830 In the following conditions: ❶ Air: 35°C - Water: 7/12°C - ❷ Air: 7°C D.B. - 6°C W.U.- Water 40/45°C ❸ At 5 m from the unit, coil side, in free field (Q = 2). ❹ Total sound power level in dB(A) on the basis of measurements taken in accordance with ISO 3744. ● ESEER (European Sesonal EER) - European seasonal average efficiency 290 2100 83,0 96,0 2,56 2,69 32,4 35,7 290 2100 88,0 101,2 88,0 101,2 82,5 95,0 2,90 2,90 2,90 2,90 2,62 2,73 4,35 4,32 30,3 34,9 30,3 34,9 31,5 34,8 290 2100 96,0 111,0 96,0 111,0 3,29 3,34 3,29 3,34 85,2 99,3 85,2 99,3 29,2 33,2 29,2 33,2 290 2100 60 62 56 57 54 55 52 53 82 84 77 78 75 76 73 74 2/3 2/3 1 1 400-3ph+N-50 290 2100 2.650 3.150 3.150 3.150 1.700 1.700 1.520 1.520 1.210 1.210 1.210 1.210 870 945 910 980 975 1045 2115 110,5 2,72 40,6 2115 114,5 108,0 101,0 2,93 2,67 2,34 4,37 39,1 40,4 43,2 2115 122,0 120,0 3,21 3,22 111,0 107,2 38,0 37,3 2115 68 60 57 54 90 84 81 78 2/3 1 2130 120,5 2,64 45,6 2130 126,0 119,0 108,0 2,91 2,67 2,30 4,31 43,3 44,6 47,0 2130 139,0 135,0 3,31 3,31 123,8 118,5 42,0 40,8 2130 68 60 57 54 90 84 81 78 2/2 1 2145 138,5 2,66 52,1 2145 143,0 136,0 125,0 2,90 2,63 2,32 4,29 49,3 51,7 53,9 2145 157,0 154,0 3,22 3,25 141,3 135,6 48,8 47,4 2145 68 62 58 55 90 85 82 79 2/3 1 2160 155,0 2,61 59,4 2160 161,0 151,0 138,0 2,90 2,60 2,20 4,26 55,5 58,1 62,7 2160 175,0 170,0 3,21 3,21 159,8 150,2 54,5 53,0 2160 69 62 58 55 91 85 82 79 2/2 1 2115 3.150 3.250 1.730 2.000 1.210 1.520 1.020 1.130 1.215 2130 3.150 3.250 1.730 2.000 1.210 1.520 1.040 1.195 1.285 2145 3.150 3.250 1.730 2.000 1.210 1.520 1.100 1.225 1.315 2160 3.450 3.250 1.730 2.000 1.210 1.520 1.160 1.290 1.390 TCAESY-THAESY silenced versions TCAEQY supersilenced versions WATER CHILLERS - HEAT PUMPS Macrosystem 67÷161 kW 79÷175 kW AVAILABLE FROM JUNE 2008 TCAEY-THAEY 4160÷4320 Y-Pack Range Packaged air-cooled reversible water chillers and heat pumps with axial fans. Range with hermetic Scroll compressors and R410A refrigerant gas. Construction features Compressor: hermetic, rotary Scroll compressor, complete with thermal protection and crankcase heater. 4 capacity steps with high efficiency at partial loads. Water side heat exchanger: stainless steel plate exchanger, complete with closed cell polyurethane foam rubber insulation and water flow differential pressure switch. Air side heat exchanger: finned coil exchanger, with copper pipes and aluminium fins. Fan: axial fan with external rotor, equipped with internal thermal protection and complete with protection grille. Control: microprocessor electronic control iDRHOSS compatible, with Adaptive Function Plus logic for connection with the main BMS on the market (MODBUS RTU, LON). Structure: load-bearing structure in galvanised and painted sheet steel with polyester powder coating. The unit is also complete with: • Unit with compressor and fan thermal overload switches. Versions • B - Standard version (TCAEBY). • T - High temperature/efficiency version with larger coil surface (TCAETY-THAETY). • S - Silenced version complete with soundproofed compressor compartment, lower fan speed and larger coil surface (TCAESY-THAESY). • Q - Supersilenced version complete with soundproofed compressor compartment, super-low fan speed and larger coil surface (TCAEQY). Models TCAEBY: standard unit designed for cooling only. TCAETY: high temperature/efficiency unit designed for cooling only. TCAESY: silenced unit designed for cooling only. TCAEQY: supersilenced unit designed for cooling only. THAETY: heat pump unit. THAESY: silenced heat pump unit. Factory fitted accessories • PUMP with single or double pump, including an automatic pump in standby, complete with expansion tank, safety valve and water pressure gauge. The pumps are available in the low or high pressure versions. • TANK&PUMP with up to 1100-litre built-in buffer tank and single or double pump, complete with expansion tank, air bleed valves, safety valve and water pressure gauge. • Desuperheater. • 100% heat recovery. • Electronic expansion valve • -10°C condensation control. • Power factor correction capacitors (cosφ > 0.91). • Soundproofing kit (TCAEBY only). • Refrigerant circuit high and low pressure gauges. • Metal filters or coil protection grilles. • Unit with copper/copper, copper/tin-plated copper or copper/pre-painted aluminium coils. • Digital input for double set-point • 4-20 mA analogue input for shifting set-point. • Evaporator antifreeze heater, buffer tank, pumps and heat exchangers for heat recovery if present. • Serial interface for connection with external BMS. Accessories supplied loose • Antivibration mountings. • Remote keyboard with display. • Clock card • GSM 900/1800 modem kit for remote unit management. • Rhoss supervision system for unit monitoring and remote management. P. 27 Macrosystem 138÷325 kW 159,6÷342 kW TCAEBY MODEL ❶ Nominal cooling capacity ❶ E.E.R. ❶ Absorbed power TCAETY-TCAESY-TCAEQY MODEL ❶ Nominal cooling capacity ❶ Nominal cooling capacity ❶ Nominal cooling capacity ❶ E.E.R. ❶ E.E.R. ❶ E.E.R. ● E.S.E.E.R. ❶ Absorbed power ❶ Absorbed power ❶ Absorbed power THAETY-THAESY MODEL ➋ Nominal heating capacity ➋ Nominal heating capacity ➋ C.O.P. ➋ C.O.P. ❶ Nominal cooling capacity ❶ Nominal cooling capacity ➋ Absorbed power ➋ Absorbed power TCAEY-THAEY MODEL ❸ Sound pressure level TCAEBY ❸ Sound pressure level TCAETY - THAETY ❸ Sound pressure level TCAESY - THAESY ❸ Sound pressure level TCAEQY ❹ Sound power level TCAEBY ❹ Sound power levelTCAETY - THAETY ❹ Sound power level TCAESY - THAESY ❹ Sound power level TCAEQY Scroll/step compressor Circuits Main supply DIMENSIONS AND WEIGHTS L - Width version B L - Width TCAETY/TCAESY/TCAEQY L - Width THAETY - THAESY H - Height version B H - Height version T - S H - Height version Q P - Depth version B P - Depth version T - S - Q kW kW kW kW kW kW kW kW kW kW kW kW kW kW dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) No. No. V-ph-Hz mm mm mm mm mm mm mm mm 4160 152,0 2,57 59,1 4160 160,0 153,0 138,0 2,87 2,74 2,24 4,25 55,7 55,8 61,6 4160 166,0 159,6 3,03 3,00 158,0 151,0 54,8 53,2 4160 70 63 59 56 93 86 83 80 4/4 2 4180 170,0 2,51 67,7 4180 182,0 177,0 164,0 2,80 2,70 2,45 4,20 65,0 65,6 66,9 4180 188,0 182,7 2,85 2,89 179,0 174,0 66,0 63,2 4180 70 67 61 58 93 92 86 83 4/4 2 4160 3.140 3.797 3.797 2.140 2.049 2.049 1.200 2.062 4180 3.140 3.797 3.797 2.140 2.100 2.049 1.200 2.062 In the following conditions: ❶ Air: 35°C - Water: 7/12°C - ❷ Air: 7°C D.B. - 6°C W.U.- Water 40/45°C ❸ At 5 m from the unit, coil side, in free field (Q = 2). ❹ Total sound power level in dB(A) on the basis of measurements taken in accordance with ISO 3744. ➎ Weight refers to the non-accessorised unit when empty. ● ESEER (European Sesonal EER) - European seasonal average efficiency TCAESY-THAESY silenced versions TCAEQY supersilenced versions 4200 191,0 2,51 76,1 4200 200,5 192,0 181,0 2,75 2,60 2,25 4,13 72,9 73,8 80,4 4200 220,0 211,1 2,98 3,00 197,0 189,0 73,8 70,4 4200 70 67 61 58 93 92 86 83 4/4 2 4230 219,0 2,53 86,6 4230 225,0 215,0 211,0 2,75 2,60 2,45 4,13 81,8 82,7 86,1 4230 241,0 233,1 2,96 2,98 222,0 212,0 81,4 78,2 4230 72 68 62 59 95 93 87 84 4/4 2 400-3ph+N-50 4200 4230 3.140 4.100 3.797 4.902 4.902 4.902 2.140 2.140 2.100 2.100 2.049 2.049 1.200 1.200 2.062 2.062 4260 244,0 2,51 97,2 4260 257,0 246,0 228,0 2,79 2,75 2,35 4,19 92,1 89,5 97,0 4260 272,0 263,6 2,93 2,97 253,0 242,0 92,8 88,8 4260 72 69 63 59 95 94 88 84 4/4 2 4290 282,0 2,52 112,0 4290 293,0 281,0 259,0 2,77 2,61 2,25 4,16 106,0 108,0 115,0 4290 309,0 303,5 2,92 3,01 289,0 277,0 106,0 101,0 4290 74 69 64 60 97 94 89 85 4/4 2 4320 315,0 2,55 124 4320 325,0 309,0 2,70 2,55 4,11 120,0 121,0 4320 342,0 332,9 2,91 2,96 320,0 304,0 118,0 112,0 4320 74 69 64 97 94 89 4/4 2 4260 4.100 4.902 4.902 2.140 2.100 2.049 1.200 2.062 4290 5.060 4.902 4.902 2.140 2.100 2.049 1.200 2.062 4320 5.060 4.902 4.902 2.140 2.100 – 1.200 2.062 WATER CHILLERS - HEAT PUMPS PRELIMINARY TCAE-THAE 270÷2160 TCAE-THAE 4155÷4320 Q-Pack Range Packaged air-cooled reversible water chillers and heat pumps with axial fans. Range with hermetic Scroll compressors and R407C refrigerant gas. Models Construction features Factory fitted accessories Compressor: hermetic, rotary Scroll compressor, complete with thermal protection and crankcase heater. 2 or 4 capacity steps with high efficiency at partial loads. Water side heat exchanger: crossed-flow stainless steel plate exchanger, complete with closed cell polyurethane foam rubber insulation and water flow differential pressure switch. Air side heat exchanger: finned coil exchanger, with copper pipes and aluminium fins. Fan: axial fan with external rotor, equipped with internal thermal protection and complete with protection grille. Control: electronic microprocessor control with Adaptive Function logic for connection with the main BMS on the market (MODBUS RTU, LON). Structure: load-bearing structure, in galvanised and painted sheet steel with polyester powder coating, complete with soundproofed compressor compartment (mod. 290÷4320). The unit is also complete with: • Unit with compressor and fan thermal overload switches. Versions • B - Standard version complete with soundproofed technical compressor compartment (TCAEB-THAEB - models 270-280 excluded). • S - Silenced version complete with soundproofed technical compressor compartment (TCAES-THAES models 270-280), lower fan speed and larger coil surface (TCAES-THAES models 290÷4320). TCAEB: unit designed for cooling only. TCAES: silenced unit designed for cooling only. THAEB: heat pump unit. THAES: silenced heat pump unit. • PUMP with single or double pump, including an automatic pump in standby, complete with expansion tank, safety valve and water pressure gauge. The pumps are available in the low or high pressure versions. • TANK&PUMP with built-in buffer tank from 380 to 1,100 litres and single or double pump, complete with expansion tank, air bleed valves, safety valve and water pressure gauge. • 15% desuperheater. • 100% heat recovery. • Thermostat with display for the heat recovery/desuperheater. • –10°C condensation control. • Power factor correction capacitors (cosφ > 0.91). • Soft starter. • Refrigerant circuit high and low pressure gauges. • Metal filters or coil protection grilles. • Unit with copper/copper, copper/tin-plated copper or copper/pre-painted aluminium coils. • Evaporator antifreeze heater, buffer tank, pumps and heat exchangers for heat recovery if present. • Serial interface for connection with external BMS. Accessories supplied loose • Antivibration rubber mountings. • Spring antivibration mountings (mod. 4155-4320). • Remote keyboard with display. • Clock card • GSM 900/1800 modem kit for remote unit management. • Rhoss supervision system for unit monitoring and remote management. P. 29 Macrosystem 68,2÷316,2 kW 76,7÷356,2 kW TCAEB-TCAES MODEL ❶ Nominal cooling capacity ❶ Nominal cooling capacity ❶ E.E.R. ❶ E.E.R. ● E.S.E.E.R. ❶ Absorbed power ❶ Absorbed power THAEB-THAES MODEL ➋ Nominal heating capacity ➋ Nominal heating capacity ➋ C.O.P. ➋ C.O.P. ❶ Nominal cooling capacity ❶ Nominal cooling capacity ➋ Absorbed power ➋ Absorbed power TCAEB-TCAES-THAEB-THAES MODEL ❸ Sound pressure level ❸ Sound pressure level ❹ Sound power level ❹ Sound power level Scroll/step compressor Circuits Main supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth ➎ Weight TCAE ➎ Weight THAE kW kW kW kW kW kW kW kW kW kW dB(A) dB(A) dB(A) dB(A) No. No. V-ph-Hz mm mm mm kg kg 270 280 290 2100 2115 2130 2145 2160 70,1 80,9 92,9 105,6 118,2 130,0 147,4 160,3 70,1 80,9 91,6 104,1 116,6 128,2 145,3 157,1 2,98 2,96 2,81 2,78 2,76 2,73 2,89 2,78 2,98 2,96 2,78 2,73 2,72 2,67 2,85 2,70 3,56 3,48 3,33 3,34 3,29 3,25 3,41 3,27 23,5 27,3 33,0 38,0 42,8 47,7 51,0 57,6 23,5 27,3 33,0 38,1 42,9 48,0 51,0 58,1 270 280 290 2100 2115 2130 2145 2160 76,7 87,5 101,6 116,0 131,1 142,6 163,2 179,6 76,7 87,5 95,8 109,2 123,6 134,5 154,2 170,0 2,96 2,89 2,84 2,83 2,86 2,85 2,91 2,90 2,96 2,89 2,74 2,72 2,75 2,75 2,82 2,81 68,2 78,6 90,3 102,6 115,0 126,5 143,5 156,1 68,2 78,6 89,0 101,1 113,3 124,7 141,4 152,9 25,9 30,3 35,8 40,9 45,8 50,0 56,1 61,9 25,9 30,3 35,0 40,1 44,9 48,9 54,7 60,5 270 280 290 2100 2115 2130 2145 2160 55 55 58 58 60 60 62 62 54 54 55 55 57 57 58 58 76 76 83 83 84 84 85 85 75 75 79 79 81 81 82 82 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2 2 2 2 2 2 2 2 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 270 280 290 2100 2115 2130 2145 2160 3.033 3.033 3.084 3.084 3.484 3.484 3.484 3.484 1.880 1.880 2.049 2.049 2.049 2.049 2.049 2.049 1.585 1.585 1.796 1.796 1.796 1.796 1.796 1.796 1.278 1.346 1.631 1.725 1.846 1.857 1.922 1.931 1.330 1.386 1.693 1.791 1.916 1.928 1.993 2.002 4155 148,2 145,4 2,66 2,59 3,73 55,7 56,1 4155 162,2 152,7 2,65 2,54 144,0 141,3 61,1 60,0 4155 63 59 86 83 4/4 2 400-3+N-50 4155 3.797 2.049 2.062 2.158 2.256 4180 171,5 166,1 2,56 2,42 3,64 66,9 68,6 4180 188,1 176,9 2,65 2,53 166,6 161,3 71,0 69,8 4180 63 59 86 83 4/4 2 400-3+N-50 4180 3.797 2.049 2.062 2.382 2.486 In the following conditions: ❶ Air: 35°C - Water: 7/12°C - ❷ Air: 7°C D.B. - 6°C W.U.- Water 40/45°C ❸ At 5 m from the unit, coil side, in free field (Q = 2). ❹ Total sound power level in dB(A) on the basis of measurements taken in accordance with ISO 3744. 4205 204,2 201,2 2,74 2,70 3,99 74,5 74,6 4205 223,4 209,7 2,74 2,63 198,4 195,5 81,4 79,7 4205 64 60 87 84 4/4 2 400-3+N-50 4205 4.902 2.049 2.062 2.932 3.000 4235 221,7 218,5 2,59 2,54 3,73 85,6 85,9 4235 245,1 230,4 2,72 2,62 215,5 212,3 90,1 88,2 4235 64 60 87 84 4/4 2 400-3+N-50 4235 4.902 2.049 2.062 2.960 3.064 4260 247,0 236,4 2,66 2,44 3,81 92,7 97,0 4260 276,0 259,4 2,83 2,72 240,3 229,8 97,6 95,5 4260 64 60 87 84 4/4 2 400-3+N-50 4260 4.902 2.049 2.062 3.078 3.180 4290 286,9 275,4 2,68 2,54 3,78 106,9 108,5 4290 320,8 302,2 2,80 2,77 279,5 267,8 114,4 109,1 4290 69 64 93 89 4/4 2 400-3+N-50 4290 4.902 2.100 2.062 3.166 3.268 4320 316,2 306,3 2,62 2,53 3,80 120,7 120,9 4320 356,2 336,2 2,80 2,76 307,9 298,1 127,0 121,7 4320 69 64 93 89 4/4 2 400-3+N-50 4320 4.902 2.100 2.062 3.183 3.285 ➎ Weight refers to the fully accessorised unit when empty. ● ESEER (European Seasonal EER) - European seasonal average efficiency TCAES-THAES silenced versions WATER CHILLERS - HEAT PUMPS TCAEB-TCAES MODEL ❶ Nominal cooling capacity kW ❶ Nominal cooling capacity kW ❶ E.E.R. ❶ E.E.R. ● E.S.E.E.R. ❶ Absorbed power kW ❶ Absorbed power kW THAEB-THAES MODEL ➋ Nominal heating capacity kW ➋ Nominal heating capacity kW ➋ C.O.P. ➋ C.O.P. ❶ Nominal cooling capacity kW ❶ Nominal cooling capacity kW ➋ Absorbed power kW ➋ Absorbed power kW TCAEB-TCAES-THAEB-THAES MODEL ❸ Sound pressure level dB(A) ❸ Sound pressure level dB(A) ❹ Sound power level dB(A) ❹ Sound power level dB(A) Scroll/step compressor No. Circuits No. Main supply V-ph-Hz DIMENSIONS AND WEIGHTS L - Width mm H - Height mm P - Depth mm ➎ Weight TCAE kg ➎ Weight THAE kg TCAEY-THAEY 5350÷6450 Y-Power Range Packaged air-cooled reversible water chillers and heat pumps with axial fans. Range with hermetic Scroll compressors and R410A refrigerant gas. Construction features Compressor: hermetic, rotary Scroll compressor, complete with thermal protection and crankcase heater. 5 or 6 capacity steps with high efficiency at partial loads. Electronic expansion valve: as standard on all models. Water side heat exchanger: stainless steel plate exchanger with closed cell polyurethane foam rubber insulation, complete with water flow differential pressure switch and Victaulic connections. Air side heat exchanger: finned coil exchanger with copper pipes and aluminium fins. Fan: axial fan with external rotor, equipped with internal thermal protection and complete with protection grille. Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). Structure: in galvanised and painted sheet steel, with polyester powder coating. The unit is also complete with: • Low and high pressure gauges for each refrigerant circuit. Versions • B -Standard version (TCAEBY-THAEBY). • S - Silenced version with lower fan speed and soundproofed compressor cover (TCAESY-THAESY). • I -Soundproofed version with soundproofed compressor cover (TCAEIY-THAEIY). Models TCAEBY: unit designed for cooling only. TCAESY: silenced unit designed for cooling only. TCAEIY: soundproofed unit designed for cooling only. THAEBY: heat pump unit. THAESY: silenced heat pump unit. THAEIY: soundproofed heat pump unit. Factory fitted accessories • PUMP with single or double pump, including an automatic pump in standby. The pumps are available in the low or high pressure versions. • TANK&PUMP with 1,100-litre built-in buffer tank and single or double pump, complete with expansion tank, air bleed valves, safety valve and water pressure gauge. • Desuperheater. • 100% heat recovery. • Thermostat with display for the heat recovery/desuperheater. • -10°C condensation control. • -15°C condensation control. • Power factor correction capacitors (cosφ > 0.94). • Unit with compressor and fan thermal overload switches. • Bottom compartment protection grilles • Evaporator antifreeze heater, buffer tank and heat exchangers for heat recovery if present. • Digital input for double set-point • Display of refrigerant circuit high/low pressure. • Control of min/max power supply voltage. • 4-20 mA analogue input for shifting set-point. • Unit with copper/pre-painted aluminium/ copper/copper or copper/tin-plated copper coils. • Serial interface for connection with external BMS. Accessories supplied loose • Spring antivibration mountings. • Protection coil grilles • Remote keyboard with display. P. 31 TCAEBY-TCAESY MODEL 5350 6370 6410 6450 ❶ Nominal cooling capacity kW 345,1 365,3 410,2 455,1 ❶ Nominal cooling capacity kW 338,2 354,3 397,9 446,0 ❶ E.E.R. 2,85 2,81 2,68 2,60 ❶ E.E.R. 2,80 2,73 2,58 2,50 ● E.S.E.E.R. 4,30 4,35 4,31 4,26 ● E.S.E.E.R. 4,01 4,05 4,01 3,97 ❶ Absorbed power kW 121,0 130,2 153,2 175,0 ❶ Absorbed power kW 120,6 129,8 154,3 178,1 5350 6370 6410 6450 THAEBY-THAESY MODEL ➋ Nominal heating capacity kW 372,0 393,6 434,2 486,2 ➋ Nominal heating capacity kW 353,4 373,9 412,5 461,9 ➋ C.O.P. 2,95 2,92 2,89 2,84 ➋ C.O.P. 2,93 2,90 2,87 2,82 446,1 ❶ Nominal cooling capacity kW 338,2 357,8 402,0 ❶ Nominal cooling capacity kW 331,4 350,6 394,0 437,2 ➋ Absorbed power kW 126,0 134,7 150,2 170,9 ➋ Absorbed power kW 120,6 128,9 143,8 163,7 5350 6370 6410 6450 78 TCAEBY-TCAESY-THAEBY-THAESY MODEL ➌ Sound pressure level dB(A) 77 77 78 ➌ Sound pressure level dB(A) 71 71 72 72 ❹ Sound power level dB(A) 95 95 96 96 ❹ Sound power level dB(A) 89 89 90 90 Scroll/step compressor No. 5/5 6/6 6/6 6/6 Circuits No. 2 2 2 2 Main supply V-ph-Hz 400-3-50 400-3-50 400-3-50 400-3-50 DIMENSIONS AND WEIGHTS 5350 6370 6410 6450 mm 4.830 4.830 4.830 4.830 H - Height mm 2.340 2.340 2.340 2.340 P - Depth mm 2.260 2.260 2.260 2.260 ➎ Weight TCAE kg 3.300 3.450 3.500 3.520 ➎ Weight THAE kg 3.500 3.640 3.680 3.710 L - Width In the following conditions: ❶ Air: 35°C - Water: 7/12°C - ❷ Air: 7°C D.B. 6°C B.U. - Water 40/45°C ❸ At 1 m from the unit in free field (Q = 2) (average value measured on 4 sides) ❹ Total sound power level in dB(A) on the basis of measurements taken in accordance with ISO 3744. ➎ Weight refers to the accessorised unit when empty with RPE - KRP ● ESEER (European Seasonal EER) - European seasonal average efficiency TCAESY-THAESY silenced versions H P L WATER CHILLERS - HEAT PUMPS Macrosystem 331,4÷455,1 kW 353,4÷486,2 kW TCAV 1280÷2450 Q-Power Range Packaged air cooled water chillers with axial fans. Range with semihermetic screw compressors and R407C refrigerant gas. Construction features Compressor: high energy efficiency semi-hermetic screw compressor, with star-delta limited start and thermal protection, crankcase heater and compressor dischage shut-off valve. Water side heat exchanger: shell and tube exchanger complete with air bleed valve, water drain tap, closed cell polyurethane rubber insulation and Victaulic connections.. Air side heat exchanger: finned coil exchanger with copper pipes and aluminium fins. Fan: axial fan with external rotor, equipped with internal thermal protection and complete with protection grille. Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). Structure: in galvanised and painted sheet steel, with polyester powder coating. The unit is also complete with: • Low and high pressure gauges for each refrigerant circuit. Versions • B -Standard version (TCAVB). • S - Silenced version with soundproofed compressor, lower fan speed and larger coil surface (TCAVS). • I - Soundproofed version with soundproofed compressor cover (TCAVI). Models TCAVB: unit designed for cooling only. TCAVS: silenced unit designed for cooling only. TCAVI: soundproofed unit designed for cooling only. Factory fitted accessories • 15% desuperheater. • 100% heat recovery. • Thermostat with display for the heat recovery/desuperheater. • -10°C condensation control. • -15°C condensation control. • Power factor correction capacitors (cosφ > 0.91). • Unit with compressor and fan thermal overload switches. • Unit with inlet compressor shut-off valves. • Bottom compartment protection grilles. • Unit with stepless capacity control. • Electronic expansion valve • Unit with copper/pre-painted aluminium/ copper/copper or copper/tin-plated copper coils. • Water differential pressure switch • Evaporator antifreeze electric heater. • Serial interface for connection with external BMS. Accessories supplied loose • Antivibration rubber mountings. • Spring antivibration mountings. • Protection coil grilles. • Remote keyboard with display. • Clock card P. 33 Macrosystem 264,0÷445,5 kW 1280 1320 1360 2410 2450 ❶ Nominal cooling capacity kW 277,62 318,90 355,93 411,64 445,50 ❶ Nominal cooling capacity kW 425,48 264,05 303,79 336,51 393,99 ❶ E.E.R. 2,71 2,66 2,68 2,70 2,67 ❶ E.E.R. 2,60 2,54 2,56 2,56 2,54 ❶ Absorbed power kW 102,5 120,0 132,7 152,7 167,0 ❶ Absorbed power kW 101,6 119,7 131,7 153,6 167,3 ❸ Sound pressure level dB(A) 67 67 67 68 68 ❸ Sound pressure level dB(A) 61 61 61 62 62 Screw compressor/steps No. 1/3 1/3 1/3 2/6 2/6 Circuits No. Main supply V-ph-Hz 1 1 1 2 2 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 1280 1320 1360 2410 2450 mm 3.550 3.550 3.550 4.550 4.550 H - Height mm 2.350 2.350 2.350 2.350 2.350 P - Depth mm 2.325 2.325 2.325 2.325 2.325 ❹ Weight TCAVB-TCAVI kg 2.595 2.720 2.773 3.756 3.816 ❹ Weight TCAVS kg 2.751 2.876 2.929 3.964 4.024 DIMENSIONS AND WEIGHTS L - Width In the following conditions: ❶ Air: 35°C - Water: 7/12°C ❸ At 5 m from the unit in free field (Q = 2). ❹ Weight refers to unit when empty. TCAVS silenced versions H L P WATER CHILLERS - HEAT PUMPS TCAVB-TCAVS-TCAVI MODEL TCAVZ 2330÷2700 H.E. Z-Power Range E.E.R. > 3,1 High energy efficiency packaged air cooled water chillers with axial fans. Range with semihermetic screw compressors and R134a refrigerant gas. Models Construction features • Shell and tube evaporator (mod. 2330÷2460). • PUMP with single or double pump, including an automatic pump in standby. The pumps are available in the low or high pressure versions. • TANK&PUMP (mod. 2330÷2460) with 1,100-litre built-in buffer tank and single or double pump, complete with expansion tank, air bleed valves, safety valve and water pressure gauge. • Desuperheater. • 100% heat recovery. • Thermostat with display for the heat recovery/desuperheater. • -10°C condensation control. • -15°C condensation control. • Power factor correction capacitors (cosφ > 0.94). • Unit with compressor and fan thermal overload switches. • Unit with compressor shut-off valves. • Bottom compartment protection grilles • Unit with linear capacity control compressors. (25-100%). • Evaporator antifreeze heater, buffer tank and heat exchangers for heat recovery if present. • Digital input for double set-point • Display of refrigerant circuit high/low pressure. • Compressor oil level sensor. • Control of min/max power supply voltage. • 4-20 mA analogue input for shifting set-point. • Unit with copper/pre-painted aluminium/ copper/copper or copper/tin-plated copper coils. • Serial interface for connection with external BMS. Compressor: high energy efficiency semi-hermetic screw compressor, with star-delta limited start and complete with thermal protection, crankcase heater and compressor discharge shut-off valve. Electronic expansion valve: as standard on all models. Water side heat exchanger (mod. 2330÷2460): stainless steel plate exchanger with closed cell polyurethane foam rubber insulation, complete with water flow differential pressure switch and Victaulic connections. Water side heat exchanger (mod. 2510÷2700): dry expansion shell and tube exchanger with counter-current heat exchange, complete with closed cell polyurethane rubber foam insulation, water flow differential pressure switch and Victaulic connections. Air side heat exchanger: finned coil exchanger with copper pipes and aluminium fins. Fan: axial fan with external rotor, equipped with internal thermal protection and complete with protection grille. Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). Structure: in galvanised and painted sheet steel, with polyester powder coating The unit is also complete with: • Low and high pressure gauges for each refrigerant circuit. Versions • B - High energy efficiency standard version (TCAVBZ). • S - Silenced version with lower fan speed and soundproofed compressor cover (TCAVSZ). • I - High energy efficiency soundproofed version with soundproofed compressor cover (TCAVIZ). TCAVBZ: unit designed for cooling only. TCAVSZ: silenced unit designed for cooling only. TCAVIZ: soundproofed unit designed for cooling only. Factory fitted accessories Accessories supplied loose • Spring antivibration mountings. • Protection coil grilles. • Remote keyboard with display. • Clock card P. 35 TCAVBZ-TCAVSZ-TCAVIZ H.E. MODEL 2330 2350 2370 2390 2420 2460 2510 ❶ Nominal cooling capacity kW 333,1 353,2 373,6 390,5 416,5 458,1 510,3 ❶ Nominal cooling capacity kW 324,8 344,1 361,8 379,4 406,9 443,9 495,4 ❶ E.E.R. 3,11 3,11 3,10 3,10 3,11 3,10 3,11 ❶ E.E.R. 3,09 3,06 3,04 2,96 3,08 3,04 3,01 ● E.S.E.E.R. 4,04 4,06 4,08 4,06 4,04 4,06 4,08 ● E.S.E.E.R. 3,97 3,98 3,99 3,99 3,99 3,96 3,93 ➋ IPLV 4,20 4,22 4,24 4,22 4,20 4,22 4,24 ➋ IPLV 4,13 4,14 4,15 4,15 4,15 4,12 4,09 kW 107,0 113,7 120,4 126,1 134,0 148,0 164,3 ❶ Absorbed power kW 105,1 112,5 118,9 128,1 132,2 145,9 164,4 ❸ Sound pressure level dB(A) 80 80 80 80 81 81 81 ❸ Sound pressure level dB(A) 74 74 74 74 75 75 75 Screw compressor/steps No. 2/6 2/6 2/6 2/6 2/6 2/6 2/6 Circuits No. 2 2 2 2 2 2 2 Main supply V-ph-Hz 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 ❶ Absorbed power 2330 2350 2370 2390 2420 2460 2510 mm 4.830 4.830 4.830 4.830 5.830 5.830 5.830 H - Height mm 2.430 2.430 2.430 2.430 2.430 2.430 2.430 P - Depth mm 2.260 2.260 2.260 2.260 2.260 2.260 2.260 ❹ Weight TCAVBZ kg 3.780 3.870 3.960 3.970 4.420 4.530 4.740 ❹ Weight TCAVIZ - TCAVSZ kg 4.080 4.170 4.260 4.270 4.720 4.830 5.040 DIMENSIONS AND WEIGHTS L - Width TCAVBZ-TCAVSZ-TCAVIZ H.E. MODEL 2550 2570 2610 2640 2680 2700 ❶ Nominal cooling capacity kW 545,0 570,1 611,1 644,7 674,5 693,2 ❶ Nominal cooling capacity kW 676,2 531,0 554,9 593,1 624,6 657,0 ❶ E.E.R. 3,17 3,13 3,14 3,10 3,14 3,12 ❶ E.E.R. 3,11 3,08 3,07 3,01 3,08 3,04 ● E.S.E.E.R. 4,13 4,17 4,17 4,17 4,18 4,18 ● E.S.E.E.R. 3,93 3,92 3,97 4,01 4,04 4,06 ➋ IPLV 4,29 4,34 4,34 4,34 4,34 4,35 ➋ IPLV 4,08 4,08 4,12 4,17 4,20 4,22 ❶ Absorbed power kW 172,1 182,4 194,7 207,7 214,9 222,5 ❶ Absorbed power kW 171,0 180,2 193,5 207,5 213,5 222,3 ❸ Sound pressure level dB(A) 82 82 82 82 82 82 ❸ Sound pressure level dB(A) 76 76 76 76 76 76 Screw compressor/steps No. 2/6 2/6 2/6 2/6 2/6 2/6 Circuits No. 2 2 2 2 2 2 Main supply V-ph-Hz 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 DIMENSIONS AND WEIGHTS 2550 2570 2610 2640 2680 2700 mm 6.680 6.680 6.680 6.680 7.680 7.680 H - Height mm 2.430 2.430 2.430 2.430 2.430 2.430 P - Depth mm 2.260 2.260 2.260 2.260 2.260 2.260 ❹ Weight TCAVBZ kg 5.070 5.090 5.110 5.210 6.140 6.190 ❹ Weight TCAVIZ - TCAVSZ kg 5.370 5.390 5.410 5.510 6.440 6.490 L - Width In the following conditions: ❶ Air: 35°C - Water: 7/12°C ❷ IPLV (Integrated Part Load Value) - ARI standard 550/590. ❸ At 1 m from the unit in free field (Q = 2) (average value measured on 4 sides) ❹ Empty weight refers to the accessorised unit with RPE - KRP ● ESEER (European Seasonal EER) - European seasonal average efficiency TCAVSZ silenced versions WATER CHILLERS - HEAT PUMPS Macrosystem 324,8÷693,2 kW TCAVZ 2310÷2670 Z-Power Range Packaged air cooled water chillers with axial fans. Range with semihermetic screw compressors and R134a refrigerant gas. Models TCAVBZ: unit designed for cooling only. TCAVSZ: silenced unit designed for cooling only. TCAVIZ: soundproofed unit designed for cooling only. Factory fitted accessories Construction features Compressor: high energy efficiency semi-hermetic screw compressor, with star-delta limited start and complete with thermal protection, crankcase heater and compressor discharge shut-off valve. Electronic expansion valve: as standard on all models. Water side heat exchanger (mod. 2310÷2470): stainless steel plate exchanger with closed cell polyurethane foam rubber insulation, complete with water flow differential pressure switch and Victaulic connections. Water side heat exchanger (mod. 2500÷2670): dry expansion shell and tube exchanger with counter-current heat exchange, complete with closed cell polyurethane rubber foam insulation, water flow differential pressure switch and Victaulic connections. Air side heat exchanger: finned coil exchanger with copper pipes and aluminium fins. Fan: axial fan with external rotor, equipped with internal thermal protection and complete with protection grille. Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). Structure: in galvanised and painted sheet steel, with polyester powder coating. The unit is also complete with: • Low and high pressure gauges for each refrigerant circuit. Versions • B - Standard version (TCAVBZ). • S - Silenced version with lower fan speed and soundproofed compressor cover (TCAVSZ). • I - Soundproofed version with soundproofed compressor cover (TCAVIZ). • Shell and tube evaporator (mod. 2310÷2470). • PUMP with single or double pump, including an automatic pump in standby. The pumps are available in the low or high pressure versions. • TANK&PUMP (mod. 2310÷2470) with 1,100-litre built-in buffer tank and single or double pump, complete with expansion tank, air bleed valves, safety valve and water pressure gauge. • Desuperheater. • 100% heat recovery. • Thermostat with display for the heat recovery/desuperheater. • -10°C condensation control. • -15°C condensation control. • Power factor correction capacitors (cosφ > 0.94). • Unit with compressor and fan thermal overload switches. • Unit with inlet compressor shut-off valves. • Bottom compartment protection grilles • Unit with linear capacity control compressors. (25-100%). • Evaporator antifreeze heater, buffer tank and heat exchangers for heat recovery if present. • Digital input for double set-point • Display of refrigerant circuit high/low pressure. • Compressor oil level sensor. • Control of min/max power supply voltage. • 4-20 mA analogue input for shifting set-point. • Unit with copper/pre-painted aluminium/ copper/copper or copper/tin-plated copper coils. • Serial interface for connection with external BMS. Accessories supplied loose • Spring antivibration mountings. • Protection coil grilles. • Remote keyboard with display. • Clock card P. 37 TCAVBZ-TCAVSZ-TCAVIZ MODEL 2310 2320 2340 2360 2400 2430 2470 ❶ Nominal cooling capacity kW 307,2 326,0 345,2 367,4 394,8 427,9 467,4 ❶ Nominal cooling capacity kW 297,5 315,0 334,5 353,0 382,9 413,4 450 2,83 2,84 2,82 2,80 2,86 2,83 2,80 2,66 ❶ E.E.R. ❶ E.E.R. 2,74 2,73 2,71 2,62 2,78 2,72 ● E.S.E.E.R. 3,95 3,96 3,96 3,98 3,99 3,91 3,83 ● E.S.E.E.R. 3,75 3,78 3,81 3,83 3,86 3,73 3,60 ➋ IPLV 4,11 4,11 4,12 4,13 4,15 4,07 3,98 ➋ IPLV 3,90 3,93 3,96 3,99 4,01 3,88 3,74 kW 108,4 114,8 122,3 131,4 138,2 151,1 166,7 ❶ Absorbed power kW 108,5 115,5 123,6 134,9 137,8 152,1 169,0 ❸ Sound pressure level dB(A) 79 79 79 79 80 80 80 ❸ Sound pressure level dB(A) 73 73 73 73 74 74 74 Screw compressor/steps No. 2/6 2/6 2/6 2/6 2/6 2/6 2/6 Circuits No. 2 2 2 2 2 2 2 Main supply V-ph-Hz 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 ❶ Absorbed power 400-3-50 400-3-50 2310 2320 2340 2360 2400 2430 2470 mm 3.830 3.830 3.830 3.830 4.830 4.830 4.830 H - Height mm 2.430 2.430 2.430 2.430 2.430 2.430 2.430 P - Depth mm 2.260 2.260 2.260 2.260 2.260 2.260 2.260 ❹ Weight TCAVBZ kg 3.420 3.490 3.500 3.580 3.920 4.100 4.280 ❹ Weight TCAVIZ - TCAVSZ kg 3.720 3.790 3.800 3.880 4.220 4.400 4.580 DIMENSIONS AND WEIGHTS L - Width TCAVBZ-TCAVSZ-TCAVIZ MODEL 2500 2540 2580 2600 2650 2670 ❶ Nominal cooling capacity kW 505,7 538,1 575,5 607,4 646,8 665,9 ❶ Nominal cooling capacity kW 490,3 520,9 555,4 584,5 627,9 647,1 ❶ E.E.R. 2,87 2,87 2,87 2,81 2,87 2,83 ❶ E.E.R. 2,79 2,77 2,74 2,67 2,77 2,71 ● E.S.E.E.R. 3,91 3,99 3,97 3,95 3,96 3,96 ● E.S.E.E.R. 3,72 3,84 3,83 3,82 3,81 3,80 ➋ IPLV 4,07 4,15 4,13 4,11 4,11 4,12 ➋ IPLV 3,87 3,99 3,98 3,97 3,96 3,95 kW 176,1 187,3 200,7 215,9 225,4 235,7 ❶ Absorbed power kW 175,8 187,8 202,6 219,2 226,7 238,6 ❸ Sound pressure level dB(A) 81 81 81 81 82 82 ❸ Sound pressure level dB(A) 75 75 75 75 76 76 Screw compressor/steps No. 2/6 2/6 2/6 2/6 2/6 2/6 Circuits No. 2 2 2 2 2 2 Main supply V-ph-Hz 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 ❶ Absorbed power DIMENSIONS AND WEIGHTS 2500 2540 2580 2600 2650 2670 mm 5.830 5.830 5.830 5.830 6.680 6.680 H - Height mm 2.430 2.430 2.430 2.430 2.430 2.430 P - Depth mm 2.260 2.260 2.260 2.260 2.260 2.260 ❹ Weight TCAVBZ kg 4.760 4.780 4.800 4.820 5.160 5.210 ❹ Weight TCAVIZ - TCAVSZ kg 5.060 5.080 5.100 5.120 5.460 5.510 L - Width In the following conditions: ❶ Air: 35°C - Water: 7/12°C ❷ IPLV (Integrated Part Load Value) - ARI standard 550/590. ❸ At 1 m from the unit in free field (Q = 2) (average value measured on 4 sides) ❹ Empty weight refers to the accessorised unit with RPE - KRP ● ESEER (European Seasonal EER) - European seasonal average efficiency TCAVSZ silenced versions WATER CHILLERS - HEAT PUMPS Macrosystem 297,5÷665,9 kW TCAVZ 2770÷21290 H.E. Z-Power Range E.E.R. > 3,2 High energy efficiency packaged air cooled water chillers with axial fans. Range with semihermetic screw compressors and R134a refrigerant gas. Construction features Compressor: high energy efficiency semi-hermetic screw compressor, with star-delta limited start and complete with thermal protection, crankcase heater and compressor discharge shut-off valve. Electronic expansion valve: as standard on all models. Water side heat exchanger: dry expansion shell and tube exchanger with counter-current heat exchange, complete with closed cell polyurethane rubber foam insulation, water flow differential pressure switch and Victaulic connections. Air side heat exchanger: finned coil exchanger with copper pipes and aluminium fins. Fan: axial fan with external rotor, equipped with internal thermal protection and complete with protection grille. Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). Structure: in galvanised and painted sheet steel, with polyester powder coating. The unit is also complete with: • Low and high pressure gauges for each refrigerant circuit. Versions • B - High energy efficiency standard version (TCAVBZ). • S - Silenced version with lower fan speed and soundproofed compressor cover (TCAVSZ). • I - High energy efficiency soundproofed version with soundproofed compressor cover (TCAVIZ). Models TCAVBZ: unit designed for cooling only. TCAVSZ: silenced unit designed for cooling only. TCAVIZ: soundproofed unit designed for cooling only. Factory fitted accessories • 15% desuperheater. • 100% heat recovery. • Thermostat with display for the heat recovery/desuperheater. • -10°C condensation control. • -15°C condensation control. • Power factor correction capacitors (cosφ > 0.94). • Unit with compressor and fan thermal overload switches. • Unit with inlet compressor shut-off valves. • Bottom compartment protection grilles • Unit with linear capacity control compressors. (25-100%). • Unit with copper/pre-painted aluminium/ copper/copper or copper/tin-plated copper coils. • Evaporator antifreeze heater and heat recovery exchangers if present. • Serial interface for connection with external BMS. Accessories supplied loose • Spring antivibration mountings. • Protection coil grilles. • Remote keyboard with display. • Lifting chain kit. P. 39 TCAVBZ-TCAVSZ-TCAVIZ H.E. MODEL 2770 2830 2890 2960 21010 21040 ❶ Nominal cooling capacity kW 764,5 831,5 887,8 956,8 1.009,7 1.037,3 ❶ Nominal cooling capacity kW 746,0 811,2 865,5 924,0 973,5 1.004,2 ❶ E.E.R. 3,35 3,31 3,26 3,37 3,35 3,35 ❶ E.E.R. 3,24 3,17 3,09 3,16 3,13 3,16 ● E.S.E.E.R. 4,45 4,39 4,34 4,48 4,47 4,45 ● E.S.E.E.R. 4,31 4,22 4,12 4,20 4,16 4,21 4,63 ➋ IPLV 4,63 4,57 4,51 4,66 4,65 ➋ IPLV 4,48 4,39 4,28 4,37 4,33 4,37 kW 228,0 251,0 272,0 284,0 301,0 310,0 ❶ Absorbed power kW 230,5 256,1 279,8 292,6 311,5 317,9 ❸ Sound pressure level dB(A) 82 82 82 83 83 83 ❸ Sound pressure level dB(A) 76 76 76 77 77 77 Screw compressor/steps No. 2/8 2/8 2/8 2/8 2/8 2/8 Circuits No. 2 2 2 2 2 2 Main supply V-ph-Hz 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 ❶ Absorbed power 2770 2830 2890 2960 21010 21040 L - Width mm 7.680 7.680 7.680 8.980 8.980 9.980 H - Height mm 2.430 2.430 2.430 2.430 2.430 2.430 P - Depth mm 2.260 2.260 2.260 2.260 2.260 2.260 ❹ Weight TCAVBZ kg 5.950 6.360 6.760 7.900 7.920 7.990 ❹ Weight TCAVIZ - TCAVSZ kg 6.290 6.700 7.100 8.250 8.260 8.340 DIMENSIONS AND WEIGHTS 21080 21130 21150 21220 21290 ❶ Nominal cooling capacity kW 1.079,9 1.125,9 1.154,7 1.217,9 1.283,4 ❶ Nominal cooling capacity kW 1.240,4 TCAVBZ-TCAVSZ-TCAVIZ H.E. MODEL 1.051,1 1.099,9 1.116,2 1.178,1 ❶ E.E.R. 3,36 3,23 3,43 3,40 3,39 ❶ E.E.R. 3,22 3,08 3,21 3,14 3,08 ● E.S.E.E.R. 4,48 4,29 4,57 4,53 4,51 ● E.S.E.E.R. 4,29 4,10 4,27 4,16 4,10 ➋ IPLV 4,66 4,46 4,75 4,71 4,69 ➋ IPLV 4,47 4,26 4,44 4,33 4,26 kW 321,0 349,0 336,2 358,0 379,0 ❶ Absorbed power kW 326,0 357,0 348,0 375,8 402,2 ❸ Sound pressure level dB(A) 84 84 84 84 84 ❸ Sound pressure level dB(A) 78 78 78 78 78 Screw compressor/steps No. 2/8 2/8 2/8 2/8 2/8 Circuits No. 2 2 2 2 2 Main supply V-ph-Hz 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 ❶ Absorbed power 21080 21130 21150 21220 21290 mm 10.980 10.980 10.980 10.980 10.980 H - Height mm 2.430 2.430 2.430 2.430 2.430 P - Depth mm 2.260 2.260 2.260 2.260 2.260 ❹ Weight TCAVBZ kg 7.960 8.720 9.160 9.200 9.240 ❹ Weight TCAVIZ - TCAVSZ kg 8.300 9.070 9.510 9.560 9.590 DIMENSIONS AND WEIGHTS L - Width In the following conditions: ❶ Air: 35°C - Water: 7/12°C ❷ IPLV (Integrated Part Load Value) - ARI standard 550/590. ❸ At 1 m from the unit in free field (Q = 2) (average value measured on 4 sides) ❹ Empty weight refers to the accessorised unit with RPE - KRP ● ESEER (European Seasonal EER) - European seasonal average efficiency TCAVSZ silenced versions WATER CHILLERS - HEAT PUMPS Macrosystem 764,5÷1.283,4 kW TCAVZ 2750÷21250 Z-Power Range Packaged air cooled water chillers with axial fans. Range with semihermetic screw compressors and R134a refrigerant gas. Versions • B - Standard version (TCAVBZ). • S - Silenced version with lower fan speed and soundproofed compressor cover (TCAVSZ). • I - Soundproofed version with soundproofed compressor cover (TCAVIZ). Construction features Compressor: high energy efficiency semi-hermetic screw compressor, with star-delta limited start and complete with thermal protection, crankcase heater and compressor discharge shut-off valve. Electronic expansion valve: as standard on all models. Water side heat exchanger: dry expansion shell and tube exchanger with counter-current heat exchange, complete with closed cell polyurethane rubber foam insulation, water flow differential pressure switch and Victaulic connections. Air side heat exchanger: finned coil exchanger with copper pipes and aluminium fins. Fan: axial fan with external rotor, equipped with internal thermal protection and complete with protection grille. Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). Structure: in galvanised and painted sheet steel, with polyester powder coating. The unit is also complete with: • Low and high pressure gauges for each refrigerant circuit. Models TCAVBZ: unit designed for cooling only. TCAVSZ: silenced unit designed for cooling only. TCAVIZ: soundproofed unit designed for cooling only. Factory fitted accessories • 15% desuperheater. • 100% heat recovery. • Thermostat with display for the heat recovery/desuperheater. • -10°C condensation control. • -15°C condensation control. • Power factor correction capacitors (cosφ > 0.94). • Unit with compressor and fan thermal overload switches. • Unit with inlet compressor shut-off valves. • Bottom compartment protection grilles • Unit with linear compressor capacity control (25-100 %). • Unit with copper/pre-painted aluminium/ copper/copper or copper/tin-plated copper coils. • Evaporator antifreeze heater and heat recovery exchangers if present. • Serial interface for connection with external BMS. Accessories supplied loose • Spring antivibration mountings. • Protection coil grilles. • Remote keyboard with display. • Lifting chain kit. P. 41 TCAVBZ-TCAVSZ-TCAVIZ MODEL 2750 2810 2870 2940 2990 ❶ Nominal cooling capacity kW 751,1 809,3 863,4 935,5 984,6 ❶ Nominal cooling capacity kW 732,0 785,9 838,0 908,6 954,0 ❶ E.E.R. 2,98 2,96 2,91 3,01 2,98 ❶ E.E.R. 2,85 2,82 2,77 2,86 2,81 ● E.S.E.E.R. 3,96 3,93 3,88 4,00 3,98 ● E.S.E.E.R. 3,79 3,76 3,69 3,80 3,73 ➋ IPLV 4,12 4,09 4,03 4,17 4,14 ➋ IPLV 3,94 3,91 3,83 3,95 3,89 kW 252,0 273,2 296,2 310,6 329,9 ❶ Absorbed power kW 257,0 278,4 303,0 318,2 339,6 ❸ Sound pressure level dB(A) 82 82 82 82 82 ❸ Sound pressure level dB(A) 76 76 76 76 76 Screw compressor/steps No. 2/8 2/8 2/8 2/8 2/8 Circuits No. 2 2 2 2 2 Main supply V-ph-Hz 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 ❶ Absorbed power DIMENSIONS AND WEIGHTS 2750 2810 2870 2940 2990 mm 6.680 7.680 7.680 7.680 7.680 H - Height mm 2.430 2.430 2.430 2.430 2.430 P - Depth mm 2.260 2.260 2.260 2.260 2.260 ❹ Weight TCAVBZ kg 5.310 6.400 6.620 6.790 6.820 ❹ Weight TCAVIZ - TCAVSZ kg 5.610 6.750 6.970 7.140 7.170 L - Width TCAVBZ-TCAVSZ-TCAVIZ MODEL 21020 21060 21110 21180 21250 ❶ Nominal cooling capacity kW 1.015,5 1.051,6 1.107,3 1.179,7 1.251,5 ❶ Nominal cooling capacity kW 1.212,2 984,6 1.019,7 1.071,8 1.142,7 ❶ E.E.R. 3,05 3,13 2,99 3,07 3,15 ❶ E.E.R. 2,87 2,95 2,78 2,85 2,90 ● E.S.E.E.R. 4,05 4,18 3,98 4,09 4,19 ● E.S.E.E.R. 3,82 3,93 3,70 3,77 3,87 ➋ IPLV 4,21 4,34 4,14 4,25 4,35 ➋ IPLV 3,97 4,09 3,85 3,93 4,02 kW 333,4 335,7 370,5 384,3 397,7 ❶ Absorbed power kW 343,3 346,0 385,0 401,2 417,3 ❸ Sound pressure level dB(A) 82 83 83 83 83 ❸ Sound pressure level dB(A) 76 77 77 77 77 Screw compressor/steps No. 2/8 2/8 2/8 2/8 2/8 Circuits No. 2 2 2 2 2 Main supply V-ph-Hz 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 ❶ Absorbed power DIMENSIONS AND WEIGHTS 21020 21060 21110 21180 21250 L - Width mm 7.680 7.680 8.980 8.980 8.980 H - Height mm 2.430 2.430 2.430 2.430 2.430 P - Depth mm 2.260 2.260 2.260 2.260 2.260 ❹ Weight TCAVBZ kg 6.940 6.970 8.530 8.740 8.930 ❹ Weight TCAVIZ - TCAVSZ kg 7.290 7.390 8.880 9.090 9.280 In the following conditions: ❶ Air: 35°C - Water: 7/12°C ❷ IPLV (Integrated Part Load Value) - ARI standard 550/590. ❸ At 1 m from the unit in free field (Q = 2) (average value measured on 4 sides) ❹ Empty weight refers to the accessorised unit with RPE - KRP ● ESEER (European Seasonal EER) - European seasonal average efficiency TCAVSZ silenced versions WATER CHILLERS - HEAT PUMPS Macrosystem 732÷1.251,5 kW TCCEY-THCEY 105÷111 Mini-Y Range Packaged air-cooled reversible water chillers and heat pumps with centrifugal fans. Range with hermetic Scroll compressors and R410A. refrigerant gas. Construction features Compressor: hermetic, rotary Scroll compressor, complete with thermal protection. Water side heat exchanger: adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water flow differential pressure switch. Air side heat exchanger: featuring finned coil with copper pipes and aluminium fins, complete with protection grille. Fan: centrifugal electric fan with directly coupled motor, fitted with internal thermal protection and protection grilles. Control: microprocessor electronic control available in 2 versions: Standard and iDRHOSS compatible, with Adaptive Function logic. Structure: in galvanised and painted sheet steel, complete with condensation drain pan for THCEY. TANK & PUMP unit • with standard pump. • with high-pressure pump. Pumping group complete with: water buffer tank, standard or high-pressure circulation pump for models 105-107 only, expansion tank with membrane, manual air bleed valve, automatic air bleed valve and safety valve. Factory fitted accessories • • • • Soft - start device (for models with power supply 230V). -10°C condensation control. Low pressure switch. Crankcase heater compressor. Option with control • Digital input for double set-point • 4-20 mA analogue input for shifting set-point. Accessories supplied loose PUMP unit • • • • • • • • • • with standard pump. • with high-pressure pump. Pumping group complete with: standard or high-pressure circulation pump for models 105-107 only, expansion tank with membrane and safety valve. Option with control Models TCCEY: unit designed for cooling only. THCEY: heat pump unit. Antivibration rubber mountings. -10°C condensation control. Water filter Low pressure switch. Antifreeze electric heater on the buffer tank. Inlet antivibration connection. Outlet antivibration connection. Remote keyboard with display. Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). • Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. • Clock card • Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. • GSM 900/1800 modem kit for remote unit management. • Rhoss supervision system for unit monitoring and remote management. P. 43 Microsystem 4,8÷10,4 kW 5÷11 kW TCCEY-THCEY MODEL ❶ Nominal cooling capacity kW 105 107 109 111 4,8 5,9 8,2 10,0 / 10,4 ❶ E.E.R. 2,34 2,27 2,27 2,27 / 2,36 ● E.S.E.E.R. 2,52 2,51 2,61 2,55 / 2,58 ❶ Absorbed power (*) kW 2,05 2,59 3,61 4,40 ➋ Nominal heating capacity kW 5,0 6,3 8,3 10,6 / 11,0 2,33 2,49 2,29 2,52 / 2,62 2,14 2,53 3,62 4,20 49 49 51 52 1/1 1/1 1/1 1/1 ➋ C.O.P. ➋ Absorbed power (*) kW ❸ Sound pressure level dB(A) Scroll/step compressor No. 1 1 1 1 2.450 2.400 2.650 2.600 Circuits No. Fan nominal air flow m3/h External head pressure Pa 80 70 80 70 Water tank content l 19 19 30 30 ❶ Available head pressure of pump T kPa 60 60 87 78 230-1-50 230-1-50 / 400-3+N-50 230-1-50 / 400-3+N-50 230-1-50 / 400-3+N-50 Main supply V-ph-Hz In the following conditions: ❶ Air: 35°C - Water: 7/12°C ❷ Air: 7°C D.B. - 6°C W.B. - Water: 45/40°C. ❸ At 5 m from the unit in free field (Q = 2). ● ESEER (European Seasonal EER) - European seasonal average efficiency 105 107 109 111 L - Width mm 990 990 990 990 H - Height PUMP mm 940 940 1.125 1.125 H - Height TANK & PUMP mm 940 940 1.330 1.330 P - Depth mm 630 630 630 630 ❹ Weight TCCEY kg 143 145 164 178 ❹ Weight THCEY kg 153 155 174 188 DIMENSIONS AND WEIGHTS ❹ The weight refers to the unit in its most complete form P H L WATER CHILLERS - HEAT PUMPS (*) Unit without pump TCCE-THCE 114÷126 Compact Range Packaged air-cooled reversible water chillers and heat pumps with centrifugal fans. Range with hermetic Scroll compressors and R407C refrigerant gas. Construction features Compressor: hermetic, rotary Scroll compressor, complete with thermal protection. Water side heat exchanger: adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water flow differential pressure switch. Air side heat exchanger: featuring finned coil with copper pipes and aluminium fins, complete with protection grille. Fan: centrifugal electric fans with directly coupled motor, fitted with internal thermal protection and protection grilles. Control: microprocessor electronic control available in 2 versions: Standard and iDRHOSS compatible, with Adaptive Function logic. Structure: peraluman, complete with condensation drain pan for THCE. Models TCCE: unit designed for cooling only. THCE: heat pump unit. STANDARD unit Without pumping group and buffer tank. TANK & PUMP unit • With standard pump. • With high-pressure pump. Pumping group complete with: water buffer tank, standard or high-pressure circulation pump for models 114-117 only, expansion tank with membrane, manual air bleed valve, safety valve and water drain tap. Factory fitted accessories • Horizontal condensation air outlet. • Antifreeze electric heater on the buffer tank. Option with control • Digital input for double set-point • 4-20 mA analogue input for shifting set-point. Accessories supplied loose • Antivibration rubber mountings. • -10°C condensation control. • Inlet antivibration connection. • Outlet antivibration connection. • Remote keyboard with display. • Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). • Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. Option with control • Clock card • Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. • GSM 900/1800 modem kit for remote unit management. • Rhoss supervision system for unit monitoring and remote management. P. 45 Microsystem 13,5÷22 kW 13,6÷24 kW TANK & PUMP unit Circulation pump TCCE-THCE MODEL ❶ Nominal cooling capacity kW ❶ E.E.R. ❶ Absorbed power (*) kW ➋ Nominal heating capacity kW ➋ C.O.P. ➋ Absorbed power (*) kW ❸ Sound pressure level dB(A) Scroll/step compressor No. Circuits No. Fan nominal air flow m3/h External head pressure Water tank content 114 117 121 126 13,5 15,5 18,2 22,0 2,55 2,53 2,40 2,34 5,31 6,13 7,57 9,40 24,0 13,6 16,4 20,1 2,58 2,72 2,80 2,71 5,27 6,02 7,18 8,86 54 55 56 57 1/1 1/1 1/1 1/1 1 1 1 1 4.720 4.110 5.040 4.485 Pa 90 80 90 80 l 55 55 80 80 ❶ Available head pressure of standard pump kPa 50 48 170 159 ❶ Available head pressure of high pressure pump kPa 179 165 – – Main supply V-ph-Hz 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 DIMENSIONS AND WEIGHTS 114 117 121 126 L - Width mm 1.320 1.320 1.710 1.710 H - Height STANDARD mm 1.305 1.305 1.305 1.305 H - Height TANK & PUMP mm 1.600 1.600 1.600 1.600 P - Depth mm 558 558 643 643 ❹ Weight TCCE kg 340 360 420 460 ❹ Weight THCE kg 350 370 440 470 In the following conditions: ❶ Air: 35°C - Water: 7/12°C ❷ Air: 7°C D.B. - 6°C W.B. - 70% R.H. - Water: 45/40°C. ❸At 5 m from the unit in free field (Q = 2), with ducted fans. ❹ The weight refers to the unit in its most complete form (*) Unit without pump WATER CHILLERS - HEAT PUMPS Water buffer tank TCCE-TCPE-THCE-THPE 130÷270 Packaged air-cooled reversible water chillers and heat pumps with centrifugal fans. Range with hermetic Scroll compressors and R407C refrigerant gas. Construction features Compressor: hermetic rotary Scroll compressor. Water side heat exchanger: stainless steel plate exchanger with closed cell polyurethane foam rubber insulation, complete with water flow differential pressure switch. Air side heat exchanger: finned coil exchanger with copper pipes and aluminium fins. Fan: centrifugal electric fans with external motor, belt transmission and adjustable pulley. The condensation air supply is horizontal (suction side). Control: microprocessor electronic control. Structure: load-bearing galvanized and painted sheet steel structure with epoxy powder coating and compressor compartment lined internally with soundproofing material. Factory fitted accessories • TANK&PUMP with integrated buffer tank from 80 to 150 litres and single or double pump. • PUMP with pumps for primary circuit or for primary circuits and secondary circuits. • CC for unit operation in cooling mode, with external air temperature up to 10 °C. • LOW AMBIENT (TCCE-TCPE only) for unit operation with low external air temperature (down to –10°C). • Vertical condensation air supply. • Protection coil grilles • Refrigerant circuit high and low pressure gauges. • Evaporator antifreeze electric heater. Accessories supplied loose • Antivibration rubber mountings. • Water filter • Remote keyboard with display. • RS 485 serial interface. • RS 232 hardware key. Versions TANK & PUMP Accessory • B - Standard version with standard fans (TCCEB-THCEB) and high-pressure fans (TCPEB-THPEB). • Built-in pumping group complete with: water buffer tank, circulation pump, expansion tank, pressure gauge, bleed and safety valve and water drain. • The pump is available in a single or double configuration, including one in stand-by, and in 4 sizes for combination with the TCCE-TCPE and THCE-THPE units. Models TCCEB: unit designed for cooling only. THCEB: heat pump unit. TCPEB: unit designed for cooling only. THPEB: heat pump unit. PUMP Accessory Version fitted with a maximum of 3 pumps: • P - Primary circuit pump in single configuration. • DP - Primary circuit pump in double configuration, with one in stand-by. • PU - Secondary circuit pump in single configuration. • DPU - Secondary circuit pump in double configuration, in combination with primary circuit pump. P. 47 Macrosystem 30,1÷66,3 kW 34,9÷77,1 kW TCCEB-THCEB-TCPEB-THPEB MODEL 130 135 140 150 160 270 ❶ Nominal cooling capacity kW 30,1 34,5 37,3 47,2 59,4 66,3 ➋ Nominal heating capacity kW 34,9 41,2 43,1 55,9 65,3 77,1 ❸ Sound pressure level dB(A) 54 59 57 57 60 64 Scroll/step compressor No. 1/1 1/1 1/1 1/1 1/1 2/2 1 1 1 1 1 1 8.500 11.000 15.000 15.000 17.000 20.000 Circuits No. Fan nominal air flow m3/h ❶ Max. available head pressure fan Pa 145 155 125 125 150 155 ❶ Absorbed power TCCEB kW 12,1 14,5 14,9 18,7 22,9 28,8 ➋ Absorbed power THCEB kW 11,4 13,8 13,6 17,8 21,5 28,8 Main supply V-ph-Hz 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 130 135 140 150 160 270 mm 1.855 1.855 2.355 2.355 2.355 2.355 H - Height mm 1.916 1.916 1.916 1.916 1.916 1.916 P - Depth mm 910 910 1.010 1.010 1.010 1.010 ❹ Weight TCCEB-TCPEB kg 646 666 781 885 946 1.022 ❹ Weight THCEB-THPEB kg 669 687 805 910 982 1.057 DIMENSIONS AND WEIGHTS L - Width In the following conditions: ❶ Air: 35°C - Water: 7/12°C - ❷ Air: 7°C D.B. - 6°C W.B. - Water 40/45°C ❸ At 5 m from the unit in free field (Q = 1), with ducted fans. ❹ Weight refers to the fully accessorised unit when empty. TANK & PUMP TCCEB-THCEB-TCPEB-THPEB MODEL Nominal flow l/h Water tank content l 130 135 140 150 160 270 5.177 5.934 6.416 8.118 10.217 11.404 80 80 150 150 150 150 – Pump P1 KPa 136 132 138 130 – Pump P3 KPa 218 214 219 215 – – Pump P5 KPa – – – – 138 129 Pump P7 KPa – – – – 279 275 PUMP P (pump for primary circuit) TCCEB-THCEB-TCPEB-THPEB MODEL Nominal flow l/h 130 135 140 150 160 270 5.177 5.934 6.416 8.118 10.217 11.404 Available head pressure of PUMP P pump Pump P1 KPa 141 140 139 135 – – Pump P3 KPa 222 222 220 215 – – Pump P5 KPa – – – – 141 137 Pump P7 KPa – – – – 284 280 PUMP P/PU (pumps for primary and secondary circuit) TCCEB - THCEB - TCPEB - THPEB MODEL Nominal flow l/h 130 135 140 150 160 270 5.177 5.934 6.416 8.118 10.217 11.404 – Available head pressure of PUMP P/PU pump Pump P1/PU1 KPa 161 160 159 158 – Pump P1/PU3 KPa 243 242 241 239 – – Pump P5/PU5 KPa – – – – 165 164 Pump P5/PU7 KPa – – – – 309 305 WATER CHILLERS - HEAT PUMPS Available head pressure of TANK & PUMP pump TCHEY-THHEY 105÷112 Comby-Flow Range Fan coil systems Radiant Systems Geothermal applications Packaged water-cooled reversible water chillers and heat pumps on the cooling circuit. Range with hermetic Scroll compressors and R410A refrigerant gas. Construction features Compressor: hermetic, rotary Scroll compressor, complete with thermal protection. Primary side heat exchanger (user): adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water flow differential pressure switch. Well or water pipe side heat exchanger (disposal unit): adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water flow differential pressure switch (for THHEY). Control: microprocessor electronic control available in 2 versions: Standard and iDRHOSS compatible, with Adaptive Function logic. Structure: in galvanised and painted sheet steel with polyester powder coating, complete with soundproofed compressor compartment. Models TCHEY: unit designed for cooling only. THHEY: heat pump unit. STANDARD unit • Without circulation pump. Primary side (user): expansion tank with membrane, safety valve, water drain valve, manual air bleed valve, gauge. PUMP unit • With circulation pump Primary side (user): pumping group complete with circulation pump, membrane expansion tank, safety valve, water drain valve, manual air bleed valve, gauge. Factory fitted accessories • Pressure switch valve • Pressure switch valve and bypass solenoid valve (only THHEY). Option with control • Water circuit heat pump (for TCHEY only). • Digital input for double set-point • 4-20 mA analogue input for shifting set-point. Accessories supplied loose • Water buffer tank • Buffer connection pipes • Water filter • Antivibration rubber mountings. • Antifreeze electric heater on the buffer tank. • Low pressure switch. • Remote keyboard with display. • Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). • Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. Option with control • Clock card • Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. • GSM 900/1800 modem kit for remote unit management. • RHOSS supervision software for unit monitoring and remote management. P. 49 TCHEY-THHEY MODEL 105 107 109 112 5,4 6,8 9,3 12,0 ❶ E.E.R. 3,47 3,20 3,40 3,33 ● E.S.E.E.R. 3,54 3,76 3,95 3,91 ❶ Nominal cooling capacity kW ❶ Absorbed power (*) kW 1,56 2,12 2,74 3,60 ➋ Nominal heating capacity kW 6,5 8,2 10,8 13,9 3,18 2,84 3,05 3,17 2,04 2,88 3,54 4,38 ➋ C.O.P. ➋ Absorbed power (*) kW ❸ Nominal cooling capacity (radiating) kW ❸ E.E.R. (radiating) 7,6 8,9 13,2 16,5 4,75 4,24 4,89 4,46 ❸ Absorbed power (radiating) (*) kW 1,6 2,1 2,7 3,7 ❹ Heating capacity (radiating) kW 6,9 8,9 11,5 14,8 4,48 ❹ C.O.P. (radiating) 4,60 4,05 4,26 ❹ Absorbed power (radiating) (*) kW 1,5 2,2 2,7 3,3 ❺ Heating capacity (geothermal) kW 5,1 6,7 8,3 11,0 3,40 2,91 3,07 3,33 1,5 2,3 2,7 3,3 49,1 51,1 51,3 53,1 1/1 ❺ C.O.P. (geothermal) ❺ Absorbed power (geothermal) (*) kW ➏ Sound pressure level dB(A) Scroll/step compressor No. 1/1 1/1 1/1 Circuits No. 1 1 1 1 Water buffer tank content KA l 20 20 30 30 ❶ Available head pressure of pump kPa 47 55 82 78 230-1-50 230-1-50 400-3+N-50 230-1-50 400-3+N-50 230-1-50 400-3+N-50 Main supply V-ph-Hz DIMENSIONS AND WEIGHTS 105 107 109 112 L - Width mm 585 585 660 660 H - Height STANDARD - PUMP mm 535 535 535 535 H - Height STANDARD - PUMP + KA mm 855 855 855 855 P - Depth mm 386 386 420 420 ❼ Weight TCHEY P kg 75 80 90 93 ❼ Weight THHEY P kg 78 83 94 97 Weight KA kg 28 28 33 33 In the following conditions: ❶ Chilled water: 7/12°C - Condenser water: 30/35°C ❷ Hot water: 40/45°C - Evaporator water: 10°C - Flow in summer mode ❸ Chilled water: 18/23°C - Condenser water: 30/35°C ❹ Hot water: 30/35°C - Evaporator water: 10°C - Flow in summer mode ❺ Hot water: 30/35°C - Evaporator water: 0/–3°C, 30% glycol ➏ At 1 m from the unit, coil side, in free field (Q = 2). ❼ The weight refers to the unit in its most complete form Circulation pump ● ESEER (European Seasonal EER) - European seasonal average efficiency (*) STANDARD unit KA = Water buffer tank KTC = Connection pipes Pressure switch valve H H KA L P L C KT P WATER CHILLERS - HEAT PUMPS Microsystem 5,4÷12 kW 6,5÷13,9 kW TCHE-THHE 115÷165 Mini-Q Flow Range Compact Flow range (models 120-165) Packaged water-cooled reversible water chillers and heat pumps on the cooling circuit. Range with hermetic Scroll compressors and R407C refrigerant gas. Construction features Compressor: hermetic, rotary Scroll compressor, complete with thermal protection. Water side heat exchangers: stainless steel plate exchangers. The evaporator (TCHE) or evaporator/condenser (THHE) heat exchanger comes complete with water flow differential pressure switch. Control: microprocessor electronic control. Structure: in galvanised and painted sheet steel with polyester powder coating, complete with soundproofed compressor compartment. Versions • B - Standard version (TCHEB-THHEB). Models TCHEB: unit designed for cooling only. THHEB: heat pump unit. Factory fitted accessories • Refrigerant circuit high and low pressure gauges. Accessories supplied loose • Pressure switch valve • Pressure switch valve and bypass solenoid valve. (THHE only). • Antivibration rubber mountings. • Remote keyboard with display. • Serial interface for connection to BMS (proprietary protocol, Modbus RTU). • RS 485/RS232 serial converter in the event of centralised unit management. • Pumping groups with buffer tank PBHI (for models 155-165 only). P. 51 12,3÷63,6 kW 15,2÷72,4 kW TCHEB-THHEB MODEL ❶ Nominal cooling capacity kW ❶ E.E.R. 115 120 125 135 140 155 165 12,3 18,1 25,3 33,5 39,1 51,4 63,6 3,40 3,41 3,35 3,42 3,52 3,59 3,31 ❶ Absorbed power kW 3,6 5,4 7,4 9,5 10,9 15,5 18,7 ➋ Nominal heating capacity kW 15,2 22,4 31,4 41,0 47,7 58,5 72,4 3,38 3,34 3,34 3,50 3,51 3,06 3,12 4,5 6,7 9,4 11,7 13,6 19,1 23,2 ➋ C.O.P. ➋ Absorbed power kW ❸ Sound power level dB(A) 57 60 64 67 68 71 72 Scroll/step compressor No. 1/1 1/1 1/1 1/1 1/1 1/1 1/1 Circuits No. 1 1 1 1 1 1 1 Main supply V-ph-Hz 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 115 120 125 135 140 155 165 mm 750 750 750 750 750 987 987 H - Height mm 869 869 869 869 869 869 869 P - Depth mm 567 567 567 567 567 639 639 Weight TCHEB kg 177 217 232 258 281 510 530 Weight THHEB kg 187 227 242 268 291 550 570 DIMENSIONS AND WEIGHTS L - Width H L P WATER CHILLERS - HEAT PUMPS In the following conditions: ❶ TCHEB-THHEB - Condenser water: 30/35°C - Chilled water: 12/7°C. ➋ THHEB - Hot water: 40/45°C - Evaporator water: 10°C - Flow in summer mode ❸ Total sound power level in dB(A) on the basis of measurements taken in accordance with ISO 3744. TCHE-THHE 280÷4260 Q-Flow Range Packaged water-cooled reversible water chillers and heat pumps on the cooling circuit. Range with hermetic Scroll compressors and R407C refrigerant gas. Construction features Compressor: hermetic, rotary Scroll compressor, complete with thermal protection. Water side heat exchangers: stainless steel plate exchangers. The evaporator (TCHE) or evaporator/condenser (THHE) heat exchanger comes complete with water flow differential pressure switch. Control: microprocessor electronic control. Structure: in galvanised and painted sheet steel, with polyester powder coating. The unit is also complete with: • High and low pressure gauges complete with capillaries. Versions • B - Standard version (TCHEB-THHEB). • I - Soundproofed version with soundproofed compressor cover (THEY-THHEI). Models TCHEB: unit designed for cooling only. TCHEI: soundproofed unit designed for cooling only. THHEB: heat pump unit. THHEI: soundproofed heat pump unit. Accessories supplied loose • Pressure switch valve • Pressure switch valve and bypass solenoid valve. (THHE only). • Antivibration rubber mountings. • Remote keyboard with display. • Serial interface for connection to BMS (proprietary protocol, Modbus RTU). • RS 485/RS232 serial converter in the event of centralised unit management. • Inlet and outlet water manifolds (mod.4160÷4260). • Pumping group with PBHI buffer tank. P. 53 Macrosystem 76,5÷255,3 kW 86,6÷289,9 kW ❶ Nominal cooling capacity kW ❶ E.E.R. 280 2110 2130 4160 4190 4220 4240 4260 76,5 103,4 127,6 153,0 180,0 206,9 231,1 255,3 3,41 3,39 3,36 3,41 3,39 3,37 3,36 3,39 ❶ Absorbed power kW 22,6 30,8 37,4 45,2 53,4 61,6 68,2 74,8 ➋ Nominal heating capacity kW 86,6 117,4 145,0 173,1 204,0 234,9 262,4 289,9 ➋ C.O.P. 3,06 3,09 3,12 3,06 3,08 3,09 3,11 3,12 28,3 38,0 46,4 56,6 66,3 76,1 84,4 92,8 dB(A) 71 74 75 76 78 79 80 80 ❸ Sound power level dB(A) 69 72 73 74 76 77 78 78 Scroll/step compressor No. 2/2 2/2 2/2 4/4 4/4 4/4 4/4 4/4 Circuits No. 1 1 1 2 2 2 2 2 Main supply V-ph-Hz ➋ Absorbed power kW ❸ Sound power level 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 In the following conditions: ❶ TCHEB-THHEB - Condenser water: 30/35°C - Chilled water: 12/7°C. ➋ THHEB - Hot water: 40/45°C - Evaporator water: 10°C - Flow in summer mode ❸ Total sound power level in dB(A) on the basis of measurements taken in accordance with ISO 3744. DIMENSIONS AND WEIGHTS TCHEI-THHEI soundproofed versions 280 2110 2130 4160 4190 4220 4240 4260 mm 1.214 1.214 1.214 2.407 2.407 2.407 2.407 2.407 H - Height mm 1.703 1.703 1.703 1.709 1.709 1.709 1.709 1.709 P - Depth mm 873 873 873 873 873 873 873 873 Weight TCHE kg 675 825 850 982 1.110 1.217 1.246 1.270 Weight THHE kg 690 840 865 1.008 1.123 1.231 1.271 1.297 L - Width H P L WATER CHILLERS - HEAT PUMPS TCHEB-TCHEI-THHEB-THHEI MODEL TCHVZ 1200÷31630 Z-Flow Range E.E.R. > 4,75 Packaged water-cooled water chillers. Range with semihermetic screw compressors and R134a refrigerant gas. Versions Construction features Models Compressor: high energy efficiency semi-hermetic screw compressor, with part-winding or star-delta limited start (depending on model) and complete with thermal protection, crankcase heater and compressor discharge shut-off valve. Electronic expansion valve: as standard on all models. Water side heat exchanger (evaporator): dry expansion shell and tube exchanger with counter-current heat exchange, complete with closed cell polyurethane rubber foam insulation, water flow differential pressure switch and Victaulic connections. Water side heat exchanger (condenser): shell and tube complete with safety valve, and service valve on the highpressure refrigerant circuit. Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). Structure: in galvanised and painted sheet steel, with polyester powder coating. • B - Standard version (TCHVBZ). • I - Soundproofed version with soundproofed compressor cover (TCHVIZ). TCHVBZ: unit designed for cooling only. TCHVIZ: soundproofed unit designed for cooling only. Factory fitted accessories • 15% desuperheater. • 100% heat recovery. • Thermostat with display for the heat recovery/desuperheater. • Prepared for heat pump function. • Power factor correction capacitors (cosφ > 0.94). • Unit with thermal overload switches • Unit with compressor inlet shut-off valves. • Unit with stepless capacity control compressors (50-100 % for each compressor). • Evaporator antifreeze electric heater. • Digital input for double set-point • Display of refrigerant circuit high/low pressure. • Compressor oil level sensor. • Control of min/max power supply voltage. • 0-10V analogue input for condensation control performed by external device. • 4-20 mA analogue input for shifting set-point. • Serial interface for connection with external BMS. Accessories supplied loose • Spring antivibration mountings. • Antivibration rubber mountings. • Clock card • Remote keyboard with display. P. 55 TCHVBZ-TCHVIZ MODEL ❶ Nominal cooling capacity ❶ E.E.R. ● E.S.E.E.R. ❶ Absorbed power ❸ Sound power level ❸ Sound power level Screw compressor/steps Circuits Main supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth ➎ Weight TCHVBZ ➎ Weight TCHVIZ TCHVBZ-TCHVIZ MODEL ❶ Nominal cooling capacity ❶ E.E.R. ● E.S.E.E.R. ❶ Absorbed power ❸ Sound power level ❸ Sound power level Screw compressor/steps Circuits Main supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth ➎ Weight TCHVBZ ➎ Weight TCHVIZ TCHVBZ-TCHVIZ MODEL ❶ Nominal cooling capacity ❶ E.E.R. ● E.S.E.E.R. ❶ Absorbed power ❸ Sound power level ❸ Sound power level Screw compressor/steps Circuits Main supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth ➎ Weight TCHVBZ ➎ Weight TCHVIZ TCHVBZ-TCHVIZ MODEL ❶ Nominal cooling capacity ❶ E.E.R. ● E.S.E.E.R. ❶ Absorbed power ❸ Sound power level ❸ Sound power level Screw compressor/steps Circuits Main supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth ➎ Weight TCHVBZ ➎ Weight TCHVIZ kW kW dB(A) dB(A) No. No. V-ph-Hz mm mm mm kg kg kW kW dB(A) dB(A) No. No. V-ph-Hz mm mm mm kg kg kW kW dB(A) dB(A) No. No. V-ph-Hz mm mm mm kg kg kW kW dB(A) dB(A) No. No. V-ph-Hz mm mm mm kg kg 1200 199,7 4,93 5,97 40,5 94 92 1/3 1 400-3-50 1200 3.460 1.460 1.000 1.333 1.588 1230 226,3 4,92 5,72 46,0 94 92 1/3 1 400-3-50 1230 3.460 1.460 1.000 1.359 1.614 1280 277,3 4,91 5,73 56,5 97 95 1/3 1 400-3-50 1280 3.440 1.460 1.000 1.695 1.950 1310 306,3 4,89 5,69 62,7 97 95 1/3 1 400-3-50 1310 3.440 1.460 1.000 1.713 1.968 1350 347,6 4,93 5,97 70,5 97 95 1/3 1 400-3-50 1350 3.450 1.640 1.000 1.865 2.120 1410 404,6 4,93 5,89 82,1 97 95 1/3 1 400-3-50 1410 3.450 1.640 1.000 2.354 2.609 1460 462,4 4,90 5,75 94,3 97 95 1/3 1 400-3-50 1460 3.450 1.640 1.000 2.393 2.648 1530 524,9 4,90 5,72 107,2 98 96 1/3 1 400-3-50 1530 3.450 1.740 1.000 2.642 2.897 1590 589,3 4,92 6,00 119,8 98 96 1/3 1 400-3-50 1590 3.450 1.740 1.000 2.687 2.942 2400 391,7 4,90 5,70 80,0 97 95 2/6 2 400-3-50 2400 3.880 1.840 1.300 2.366 2.796 2420 413,0 4,81 5,68 85,8 97 95 2/6 2 400-3-50 2420 3.880 1.840 1.300 2.393 2.823 2440 432,0 4,75 5,60 91,0 97 95 2/6 2 400-3-50 2440 4.000 1.840 1.300 2.438 2.868 2510 506,8 4,80 5,68 105,6 99 97 2/6 2 400-3-50 2510 4.070 1.960 1.300 2.923 3.353 2560 550,8 4,94 5,93 111,5 99 97 2/6 2 400-3-50 2560 4.070 1.960 1.300 3.257 3.687 2600 592,0 4,92 5,95 120,3 99 97 2/6 2 400-3-50 2600 4.070 1.960 1.300 3.280 3.710 2630 621,6 4,93 5,83 126,1 99 97 2/6 2 400-3-50 2630 4.070 1.960 1.300 3.297 3.227 2680 676,8 4,93 5,73 137,3 99 97 2/6 2 400-3-50 2680 4.070 1.960 1.300 3.364 3.794 2710 709,8 4,93 5,71 144,1 99 97 2/6 2 400-3-50 2710 4.070 1.960 1.300 3.407 3.837 2750 742,0 4,88 5,69 152,0 99 97 2/6 2 400-3-50 2750 4.120 1.840 1.300 3.880 4.310 31300 1.282,9 4,98 6,00 257,7 101 99 3/9 3 400-3-50 31300 4.940 2.220 1.700 6.735 7.335 2790 787,0 4,83 5,72 162,8 99 97 2/6 2 400-3-50 2790 4.000 1.840 1.300 4.366 4.796 31350 1.330,0 4,93 5,89 270,0 101 99 3/9 3 400-3-50 31350 4.940 2.220 1.700 6.767 7.367 In the following conditions: ❶ Chilled water: 7/12°C - Condenser inlet water: 30/35°C ❸ Total sound power level in dB(A) on the basis of measurements taken in accordance with ISO 3744. ➎ Empty weight ● ESEER (European Seasonal EER) - European seasonal average efficiency 2880 879,1 4,92 5,98 178,7 99 97 2/6 2 400-3-50 2880 4.000 1.910 1.300 4.596 5.026 31390 1.377,2 4,87 5,87 282,9 101 99 3/9 3 400-3-50 31390 4.940 2.220 1.700 6.792 7.392 2930 927,2 4,81 5,82 192,8 99 97 2/6 2 400-3-50 2930 4.000 1.910 1.300 4.629 5.059 21030 1.016,6 4,84 5,81 210,0 99 97 2/6 2 400-3-50 21030 4.000 1.950 1.300 4.739 5.169 31460 1.437,5 4,87 5,83 295,4 102 100 3/9 3 400-3-50 31460 4.940 2.220 1.700 6.831 7.431 TCHVIZ soundproofed version 21110 1.087,3 4,88 5,96 222,8 99 97 2/6 2 400-3-50 21110 4.000 1.950 1.300 4.830 5.260 31520 1.518,5 4,91 5,90 309,0 102 100 3/9 3 400-3-50 31520 4.940 2.220 1.700 6.920 7.520 21180 1.155,8 4,92 5,86 2,34,9 99 97 2/6 2 400-3-50 21180 4.000 1.950 1.300 4.878 5.308 31590 1.580,8 4,91 5,89 321,7 102 100 3/9 3 400-3-50 31590 4.940 2.220 1.700 7.008 7.608 21260 1.208,4 4,87 5,85 248,0 99 97 2/6 2 400-3-50 21260 4.000 1.950 1.300 4.914 5.344 31630 1.629,2 4,87 5,90 334,2 102 100 3/9 3 400-3-50 31630 4.940 2.220 1.700 7.097 7.697 WATER CHILLERS - HEAT PUMPS Macrosystem 199,7÷1.629,2 kW TCEE 105÷165 Mini-Q Flow E range (models 105-115) Compact Flow E range (models 120-165) Cooling-only condenserless units to be connected to CCAM remote condensers. Range with hermetic Scroll compressors and R407C refrigerant gas. Construction features Compressor: hermetic, rotary Scroll compressor, complete with thermal protection. Water side heat exchanger: stainless steel plate exchanger complete with water flow differential pressure switch. Control: microprocessor electronic control. Structure: in galvanised and painted sheet steel with polyester powder coating, complete with soundproofed compressor compartment. Versions • B - Standard version (TCEEB). Models TCEEB: unit designed for cooling only. Factory fitted accessories • Modulating condensation control (in combination with CCAM only). • Refrigerant circuit high and low pressure gauges. Accessories supplied loose • Antivibration rubber mountings. • Remote keyboard with display. • Serial interface for connection to BMS (proprietary protocol, Modbus RTU). • RS 485/RS232 serial converter in the event of centralised unit management. • CCAM remote condensers. • Pumping groups with buffer tank PBHI (for models 155-165 only). P. 57 5,5÷62,2 kW TCEEB MODEL ❶ Nominal cooling capacity kW ❶ E.E.R. 105 115 120 125 135 140 155 165 5,5 11,6 17,2 24,3 31,8 37,1 50,2 62,2 3,30 3,58 3,52 3,58 3,68 3,74 3,40 3,49 ❶ Absorbed power kW 2,0 4,1 6,0 8,4 10,8 12,7 17,1 20,8 ➋ Sound power level dB(A) 51 57 60 64 67 68 71 72 Scroll/step compressor No. 1/1 1/1 1/1 1/1 1/1 1/1 1/1 1/1 1 Circuits No. Main supply V-ph-Hz 1 1 1 1 1 1 1 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 Recommended combinations with CCAM remote condensers TCEEB MODEL CCAM MODEL Version N "Normal" ❸ Sound pressure level CCAM MODEL Version S "Silenced" ❸ Sound pressure level CCAM MODEL Version Q "Supersilenced" ❸ Sound pressure level 105 115 120 125 135 140 155 165 – – 120 N 125 N 135 N 140 N 155 N 165 N – – 51 48 48 54 50 56 105 S 115 S 120 S 125 S 135 S 140 S 155 S 165 S 45 42 45 45 42 49 44 51 105 Q 115 Q 120 Q 125 Q 135 Q 140 Q 155 Q 165 Q 33 32 35 35 34 38 40 40 105 115 120 125 135 140 155 165 mm 750 750 750 750 750 750 987 987 H - Height mm 869 869 869 869 869 869 869 869 P - Depth mm 615 615 615 615 615 615 636 636 Weight TCEEB kg 154 172 211 224 247 270 490 505 DIMENSIONS AND WEIGHTS L - Width H L P WATER CHILLERS - HEAT PUMPS In the following conditions: ❶ Chilled water: 12/7°C - Dew point: 50°C. ➋ Total sound power level in dB(A) on the basis of measurements taken in accordance with ISO 3744. ❸ At 10 m from the unit in free field (Q = 2) TCEE 280÷4260 Q-Flow E Range Cooling-only condenserless units to be connected to CCAM remote condensers. Range with hermetic Scroll compressors and R407C refrigerant gas. Construction features Compressor: hermetic, rotary Scroll compressor, complete with thermal protection. Water side heat exchanger: stainless steel plate exchanger complete with water flow differential pressure switch. Control: microprocessor electronic control. Structure: in galvanised and painted sheet steel, with polyester powder coating. The unit is also complete with: • High and low pressure gauges complete with capillaries. Versions • B - Standard version (TCCEB). • I - Soundproofed version with soundproofed compressor cover (TCCEI). Models TCCEB: unit designed for cooling only. TCCEI: soundproofed unit designed for cooling only. Factory fitted accessories • Modulating condensation control (in combination with CCAM only). Accessories supplied loose • Antivibration mountings. • Remote keyboard with display. • Serial interface for connection to BMS (proprietary protocol, Modbus RTU). • RS 485/RS232 serial converter in the event of centralised unit management. • CCAM remote condensers. • Pumping group with PBHI buffer tank. P. 59 Macrosystem 74,2÷249 kW 280 2110 2130 4160 4190 4220 4240 4260 kW 74,2 100,4 124,5 148,4 174,6 200,8 224,9 249,0 3,47 3,44 3,51 3,47 3,46 3,44 3,48 3,51 ❶ Absorbed power kW 25,4 34,2 41,7 50,8 59,6 68,4 75,9 83,4 ➋ Sound pressure level dB(A) 71 74 75 76 78 79 80 80 ➋ Sound pressure level dB(A) 69 72 73 74 76 77 78 78 Scroll/step compressor No. 2 2 2 4 4 4 4 4 Circuits No. 1 1 1 2 2 2 2 2 Main supply V-ph-Hz 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 TCEEB-TCEEI MODEL ❶ Nominal cooling capacity ❶ E.E.R. 400-3+N-50 400-3+N-50 Recommended combinations with CCAM remote condensers 280 CCAM MODEL Version N "Normal" ❸ Sound pressure level CCAM MODEL Version S "Silenced" ❸ Sound pressure level CCAM MODEL Version Q "Supersilenced" ❸ Sound pressure level 2110 280 N 2110 N 2130 N 62 64 59 280 S 2110 S 2130 S 51 52 52 280 Q 2110 Q 2130 Q 45 43 45 In the following conditions: ❶ Chilled water: 12/7°C - Dew point: 50°C. ➋ Total sound power level in dB(A) on the basis of measurements taken in accordance with ISO 3744. ❸ At 10 m from the unit in free field (Q = 2). ▼ Each model must be combined with two condensers (one per circuit) from the CCAM range. Circuits 2130 4160(▼) 4190(▼) 4220(▼) 4240(▼) (1) 280 N 280 N 2110 N 2110 N 4260(▼) 2130 N (2) 280 N 2110 N 2110 N 2130 N 2130 N (1/2) 62/62 62/64 64/64 64/59 59/59 (1) 280 S 280 S 2110 S 2110 S 2130 S (2) 280 S 2110 S 2110 S 2130 S 2130 S (1/2) 62/62 62/64 64/64 64/59 59/59 (1) 280 Q 280 Q 2110 Q 2110 Q 2130 Q (2) 280 Q 2110 Q 2110 Q 2130 Q 2130 Q (1/2) 62/62 62/64 64/64 64/59 59/59 TCEEI soundproofed version 280 2110 2130 4160 4190 4220 4240 4260 mm 1.214 1.214 1.214 2.407 2.407 2.407 2.407 2.407 H - Height mm 1.703 1.703 1.703 1.079 1.709 1.709 1.709 1.709 P - Depth mm 873 873 873 873 873 873 873 873 Weight TCEE kg 645 790 808 906 1.015 1.121 1.140 1.157 DIMENSIONS AND WEIGHTS L - Width H P L WATER CHILLERS - HEAT PUMPS TCEEB-TCEEI MODEL TCEVZ 1200÷31630 Z-Flow E Range E.E.R. > 4,75 Cooling-only conderserless units. Range with semihermetic screw compressors and R134a refrigerant gas. Construction features Compressor: high energy efficiency semi-hermetic screw compressor, with part-winding or star-delta limited start (depending on model) and complete with thermal protection, crankcase heater and compressor discharge shut-off valve. Electronic expansion valve: as standard on all models. Water side heat exchanger (evaporator): dry expansion shell and tube exchanger with counter-current heat exchange, complete with closed cell polyurethane rubber foam insulation, water flow differential pressure switch and Victaulic connections. Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). Structure: in galvanised and painted sheet steel, with polyester powder coating. Versions • B - Standard version (TCHVBZ). • I - Soundproofed version with soundproofed compressor cover (TCHVIZ). Models TCEVBZ: unit designed for cooling only. TCEVIZ: soundproofed unit designed for cooling only. Factory fitted accessories • Power factor correction capacitors (cosφ > 0.94). • Unit with thermal overload switches • Unit with inlet compressor shut-off valves. • Unit with stepless capacity control compressors (50-100 % for each compressor). • Evaporator antifreeze electric heater. • Digital input for double set-point • Compressor oil level sensor. • Control of min/max power supply voltage. • 4-20 mA analogue input for shifting set-point. • Serial interface for connection with external BMS. Accessories supplied loose • Spring antivibration mountings. • Antivibration rubber mountings. • Clock card • Remote keyboard with display. P. 61 TCEVBZ-TCEVIZ MODEL ❶ Nominal cooling capacity ❶ E.E.R. ❶ Absorbed power ❸ Sound power level ❸ Sound power level Screw compressor/steps Circuits Main supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth ➎ Weight TCEVBZ ➎ Weight TCEVIZ TCEVBZ-TCEVIZ MODEL ❶ Nominal cooling capacity ❶ E.E.R. ❶ Absorbed power ❸ Sound power level ❸ Sound power level Screw compressor/steps Circuits Main supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth ➎ Weight TCEVBZ ➎ Weight TCEVIZ TCEVBZ-TCEVIZ MODEL ❶ Nominal cooling capacity ❶ E.E.R. ❶ Absorbed power ❸ Sound power level ❸ Sound power level Screw compressor/steps Circuits Main supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth ➎ Weight TCEVBZ ➎ Weight TCEVIZ TCEVBZ-TCEVIZ MODEL ❶ Nominal cooling capacity ❶ E.E.R. ❶ Absorbed power ❸ Sound power level ❸ Sound power level Screw compressor/steps Circuits Main supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth ➎ Weight TCEVBZ ➎ Weight TCEVIZ kW kW dB(A) dB(A) No. No. V-ph-Hz mm mm mm kg kg kW kW dB(A) dB(A) No. No. V-ph-Hz mm mm mm kg kg kW kW dB(A) dB(A) No. No. V-ph-Hz mm mm mm kg kg kW kW dB(A) dB(A) No. No. V-ph-Hz mm mm mm kg kg 1200 171,9 3,4 50,5 94 92 1/3 1 400-3-50 1200 3.440 1.460 1.000 1.078 1.333 1230 190,8 3,3 58,1 94 92 1/3 1 400-3-50 1230 3.440 1.460 1.000 1.093 1.348 1280 238,1 3,3 72,2 97 95 1/3 1 400-3-50 1280 3.420 1.460 1.000 1.410 1.665 1310 260,4 3,3 79,0 97 95 1/3 1 400-3-50 1310 3.440 1.460 1.000 1.414 1.669 1350 300,6 3,4 88,1 97 95 1/3 1 400-3-50 1350 3.450 1.640 1.000 1.557 1.812 1410 346,2 3,3 104,0 97 95 1/3 1 400-3-50 1410 3.450 1.640 1.000 2.032 2.287 1460 399,7 3,3 122,2 97 95 1/3 1 400-3-50 1460 3.450 1.640 1.000 2.038 2.293 1530 446,4 3,3 135,3 98 96 1/3 1 400-3-50 1530 3.460 1.740 1.000 2.252 2.507 1590 508,9 3,4 149,7 98 96 1/3 1 400-3-50 1590 3.460 1.740 1.000 2.281 2.536 2400 335,8 3,3 100,7 97 95 2/6 2 400-3-50 2400 3.870 1.490 1.300 1.797 2.227 2420 356,6 3,3 108,3 97 95 2/6 2 400-3-50 2420 3.870 1.490 1.300 1.811 2.241 2440 372,1 3,2 115,7 97 95 2/6 2 400-3-50 2440 3.870 1.490 1.300 1.819 2.249 2510 431,9 3,3 130,6 99 97 2/6 2 400-3-50 2510 4.070 1.610 1.300 2.311 2.741 2560 473,4 3,3 144,4 99 97 2/6 2 400-3-50 2560 4.070 1.610 1.300 2.629 3.059 2600 506,4 3,3 151,5 99 97 2/6 2 400-3-50 2600 4.070 1.610 1.300 2.637 3.067 2630 529,3 3,3 158,4 99 97 2/6 2 400-3-50 2630 4.070 1.610 1.300 2.638 3.068 2680 581,4 3,5 168,0 99 97 2/6 2 400-3-50 2680 4.070 1.610 1.300 2.698 3.128 2710 614,1 3,5 176,6 99 97 2/6 2 400-3-50 2710 4.070 1.610 1.300 2.733 3.163 2750 647,8 3,4 192,1 99 97 2/6 2 400-3-50 2750 4.120 1.490 1.300 3.176 3.606 2790 681,6 3,3 207,6 99 97 2/6 2 400-3-50 2790 4.000 1.490 1.300 3.631 4.061 31300 1.129,6 3,6 314,1 101 99 3/9 3 400-3-50 31300 4.940 1.620 2.000 5.555 6.155 In the following conditions: ❶ Chilled water: 12/7°C - Dew point: 50°C. ❸ Total sound power level in dB(A) on the basis of measurements taken in accordance with ISO 3744. ➎ Weight of fully accessorised unit when empty. 31350 1.178,3 3,6 331,8 101 99 3/9 3 400-3-50 31350 4.940 1.620 2.000 5.570 6.170 2880 753,9 3,3 226,5 99 97 2/6 2 400-3-50 2880 4.000 1.560 1.300 3.844 4.272 31390 1.227,0 3,5 349,5 101 99 3/9 3 400-3-50 31390 4.940 1.620 2.000 5.585 6.185 2930 801,4 3,3 244,4 99 97 2/6 2 400-3-50 2930 4.000 1.560 1.300 3.859 4.289 21030 896,1 3,5 257,9 99 97 2/6 2 400-3-50 21030 4.000 1.600 1.300 3.936 4.366 31460 1.287,5 3,5 367,1 102 100 3/9 3 400-3-50 31460 4.940 1.620 2.000 5.600 6.200 TCEVIZ soundproofed version 21110 959,4 3,5 271,0 99 97 2/6 2 400-3-50 21110 4.000 1.600 1.300 3.993 4.423 31520 1.340,1 3,5 380,4 102 100 3/9 3 400-3-50 31520 4.940 1.620 2.000 5.678 6.278 21180 1.027,8 3,6 285,5 99 97 2/6 2 400-3-50 21180 4.000 1.600 1.300 4.024 4.454 31590 1.388,5 3,5 393,4 102 100 3/9 3 400-3-50 31590 4.940 1.620 2.000 5.710 6.310 21260 1.101,5 3,7 299,4 99 97 2/6 2 400-3-50 21260 4.000 1.600 1.300 4.044 4.474 31630 1.424,8 3,5 406,4 102 100 3/9 3 400-3-50 31630 4.940 1.620 2.000 5.790 6.390 WATER CHILLERS - HEAT PUMPS Macrosystem 171,9÷1.424,8 kW Polyvalent ecological system. Applications of EXPSYSTEMS • EXPSYSTEMS is the polyvalent ecological system designed by RHOSS to satisfy chilled and hot water demands simultaneously or independently with a single unit, according to the operating mode chosen, i.e. AUTOMATIC or SELECT. It is designed for use in 2- and 4-pipe systems, at any time of year. How does it work? The evoluted microprocessor control manages the two EXPSYSTEMS operating modes, AUTOMATIC and SELECT, catering for the demands of 2- or 4-pipe systems. • AUTOMATIC allows for the simultaneous or separate production of chilled and hot water, in a completely automatic fashion. • SELECT allows for the production of hot water and heating water on the basis of system demands and the priorities assigned by the user. 2-pipe systems • Air conditioning and the production of hot water in a 2-pipe system is a typical application in residential units, hotels, hospitals, gyms and hospitality structures in general. • EXPSYSTEMS in AUTOMATIC mode is used in the summer months for cooling and the production of hot water. • EXPSYSTEMS in SELECT mode is used in between seasons or in winter for heating and the production of hot water on the basis of the priority assigned. 4-pipe systems • Increasingly frequently, modern HVAC installations require the simultaneous production of hot and chilled water. This can occur more often because of: - the development of new types of thermal insulation for buildings; - increase in internal loads (CED, WEB, etc.); - lighting systems; - the presence of large windows; - the growing importance attributed to air quality, which requires the use of conditioning systems throughout the year. • In these kinds of application EXPSYSTEMS can be used in AUTOMATIC mode throughout the year, catering for simultaneous or separate hot and chilled water demands in a completely automatic way. P. 63 5,4÷307,1 kW 6,5÷357,3 kW 2-pipe systems AUTOMATIC or SELECT mode Summer months “AUTOMATIC” Winter months “SELECT” cooling and hot water heating and hot water COLD WATER HOT WATER HOT WATER HOT WATER 4-pipe systems AUTOMATIC mode for the entire year Mid season Cooling cooling and heating SOUTH COLD WATER HOT WATER COLD WATER Winter months heating NORTH HOT WATER COLD WATER HOT WATER WATER CHILLERS - HEAT PUMPS Summer months TXAEY 117÷133 Compact-Y EXP Range C.O.P. > 6,1 EXPSYSTEMS - Polyvalent ecological aircooled system with axial fans. Range with hermetic Scroll compressors and R410A refrigerant gas. Construction features Compressor: hermetic, rotary Scroll compressor, complete with thermal protection and crankcase heater. Main and secondary heat exchanger: adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water flow differential pressure switch. Air side heat exchanger: finned coil exchanger with copper pipes and aluminium fins. Fan: electric axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous fan rotation speed regulation. Control: microprocessor electronic control, iDRHOSS compatible, with Adaptive Function logic. Structure: in galvanised and painted sheet steel, complete with condensation drain pan. STANDARD unit (for mod. 133 only) Without pumping group and buffer tank. PUMP unit Pumping group for main circuit complete with: circulation pump, expansion tank with membrane, manual bleed valve and safety valve, pressure gauge. TANK&PUMP unit (for mod. 133 only) Pumping group for main circuit only complete with: water buffer tank, circulation pump, expansion tank with membrane, manual air bleed valve, automatic air bleed valve and safety valve, pressure gauge. Factory fitted accessories • Antifreeze electric heater on the buffer tank. • Protection coil grilles. • Single pump with increased head pressure (mod. 133). • Single pump with increased head pressure + buffer tank (mod. 133) • Digital input for double set-point • 4-20 mA analogue input for shifting set-point. Models Accessories supplied loose TXAEY: standard EXPSYSTEMS unit. • Protection coil grilles • Antivibration rubber mountings. • Remote keyboard with display. • Clock card • Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). • Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. • Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. • GSM 900/1800 modem kit for remote unit management. • Rhoss supervision system for unit monitoring and remote management. P. 65 Microsystem 17,4÷34 kW 17,9÷39,1 kW TXAEY MODEL 117 124 130 133 ❶ Nominal cooling capacity (AUTOMATIC 1) kW 17,4 23,6 28,6 34,0 ❹ Recovery heating capacity (AUTOMATIC 2) kW 20,8 30,4 37,2 44,2 ➋ Nominal heating capacity (SELECT 1-2 AUTOMATIC 3) kW 17,9 26,1 34,4 39,1 ❶ Absorbed power (*) (AUTOMATIC 1) kW 6,4 9,4 11,7 13,3 ❹ Absorbed power (*) (AUTOMATIC 2) kW 4,9 7,4 9,8 11,5 ➋ Absorbed power (*) (SELECT 1-2 AUTOMATIC 3) kW 6,1 8,9 11,1 13,3 6,62 6,72 6,13 6,25 50 52 54 55 1/1 ❹ C.O.P. (AUTOMATIC 2) ❸ Sound pressure level dB(A) Scroll/step compressor No. 1/1 1/1 1/1 Circuits No. 1 1 1 1 Water tank content l – – – 80 ❶ Available head pressure of standard pump kPa 130 131 110 134 Main supply V-ph-Hz 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 In the following conditions: ❶ Air: 35°C - Water: 7/12°C ❷ Air: 7°C D.B. - 6°C W.B. - Water 40/45°C ❸ At 5 m from the unit in free field (Q = 2). ❹ Evaporator water: 7/12°C. Recovery outlet water 45°C - Nominal flow. DIMENSIONS AND WEIGHTS 117 124 130 133 mm 1.522 1.522 1.822 1.660 H - Height mm 1.090 1.280 1.510 1.570 P - Depth mm 580 600 695 1.000 Weight TXAEY kg 220 280 370 470 L - Width H H L L P P WATER CHILLERS - HEAT PUMPS (*) Unit without pump TXAEY 245÷265 Compact-Y EXP Range C.O.P. > 6.9 EXPSYSTEMS - Polyvalent ecological aircooled system with axial fans. Range with hermetic Scroll compressors and R410A refrigerant gas. Construction features Compressor: hermetic, rotary Scroll compressor, complete with thermal protection and crankcase heater. Main and secondary heat exchanger: adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water flow differential pressure switch. Air side heat exchanger: finned coil exchanger with copper pipes and aluminium fins. Fan: electric axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous fan rotation speed regulation. Control: microprocessor electronic control, iDRHOSS compatible, with Adaptive Function logic. Structure: in galvanised and painted sheet steel, complete with condensation drain pan. Models TXAEY: standard EXPSYSTEMS unit. Factory fitted accessories • PUMP (for main circuit only) with single or double pump, including an automatic pump in standby, complete with expansion tank, air bleed valves, safety valve and water side pressure gauge. The pumps are available in the low or high pressure versions. • TANK&PUMP (for main circuit only) with water buffer tank and single or double pump, including an automatic pump in standby, complete with expansion tank, air bleed valve, safety valve and water pressure gauge. The pumps are available in the low or high pressure versions. • Refrigerant circuit high and low pressure gauges. • Protection coil grilles. • Antifreeze electric heater for buffer tank and pumps. • Digital input for double set-point • 4-20 mA analogue input for shifting set-point. Accessories supplied loose • Protection coil grilles • Antivibration rubber mountings. • Remote keyboard with display. • Clock card • Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). • Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. • Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. • GSM 900/1800 modem kit for remote unit management. • Rhoss supervision system for unit monitoring and remote management. P. 67 Microsystem 42,6÷61,9 kW 47,8÷67,9 kW 245 250 260 265 ❶ Nominal cooling capacity (AUTOMATIC 1) kW 42,6 50,6 58,2 61,9 ❹ Recovery heating capacity (AUTOMATIC 2) kW 54,4 65,0 71,8 81,1 ➋ Nominal heating capacity (SELECT 1-2 AUTOMATIC 3) kW 47,8 55,8 62,2 67,9 ❶ Absorbed power (*) (AUTOMATIC 1) kW 16,8 18,5 21,6 24,0 ❹ Absorbed power (*) (AUTOMATIC 2) kW 13,6 15,5 17,1 19,0 ➋ Absorbed power (*) (SELECT 1-2 AUTOMATIC 3) kW 16,6 18,6 20,5 23,3 6,94 7,30 7,32 7,48 56 56 57 57 TXAEY MODEL ❹ C.O.P. (AUTOMATIC 2) ❸ Sound pressure level dB(A) Scroll/step compressor No. 2/1 2/1 2/1 2/1 Circuits No. 1 1 1 1 Main supply V-ph-Hz 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 245 250 260 265 2.260 2.260 2.260 2.260 DIMENSIONS AND WEIGHTS L - Width mm H - Height mm 1.570 1.570 1.570 1.570 P - Depth mm 1.000 1.000 1.000 1.000 Weight TXAEY kg 735 775 795 825 In the following conditions: ❶ Air: 35°C - Water: 7/12°C ❷ Air: 7°C D.B. - 6°C W.B. - Water 40/45°C ❸ At 5 m from the unit in free field (Q = 2). ❹ Evaporator water: 7/12°C. Recovery outlet water 45°C - Nominal flow. H L P WATER CHILLERS - HEAT PUMPS (*) Unit without pump TXAE 475÷4315 Q-Pack EXP Range EXPSYSTEMS - Polyvalent ecological aircooled system with axial fans. Range with hermetic Scroll compressors and R407C refrigerant gas. Construction features Compressor: hermetic, rotary Scroll compressor, complete with thermal protection and crankcase heater. Main and secondary heat exchangers: crossed-flow stainless steel plate exchangers, complete with closed cell polyurethane foam rubber insulation and water flow differential pressure switch. Air side heat exchanger: finned coil exchanger with copper pipes and aluminium fins. Fan: electric axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous fan rotation speed regulation. Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). Structure: in galvanised and painted sheet steel with polyester powder coating, complete with soundproofed compressor compartment. The unit is also complete with: • Unit with compressor and fan thermal overload switches. Versions • B - Standard version complete with soundproofed compartment (TXAEB). • I - Silenced version complete with soundproofed compressor compartment, lower fan speed and larger coil surface (TXAES). Models TXAEB: standard EXPSYSTEMS unit. TXAES: silenced EXPSYSTEMS unit. Factory fitted accessories • PUMP (for main circuit only) with single or double pump, including an automatic pump in standby, complete with expansion tank, safety valve and water side pressure gauge. The pumps are available in the low or high pressure versions. • TANK&PUMP (for main circuit only) with built-in buffer tank from 420 to 1,100 litres and single or double pump, complete with expansion tank, air bleed valves, safety valve and water pressure gauge. • Power factor correction capacitors (cosφ > 0,91). • Refrigerant circuit high and low pressure gauges. • Unit with copper/copper, copper/tin-plated copper or copper/pre-painted aluminium coils. • Main and secondary heat exchanger antifreeze heater, buffer tank and pumps if present. • Metal filters or coil protection grilles. • Serial interface for connection with external BMS. Accessories supplied loose • Antivibration rubber mountings. • Spring antivibration mountings (mod. 4200-4315). • Remote keyboard with display. • Clock card P. 69 475 495 4150 4200 4255 4315 ❶ Nominal cooling capacity (AUTOMATIC 1) kW 71,6 103,3 149,4 198,0 240,0 307,1 ❹ Recovery heating capacity (AUTOMATIC 2) kW 91,7 132,7 198,8 260,4 320,4 409,3 ➋ Nominal heating capacity (SELECT 1-2 AUTOMATIC 3) kW 80,1 113,0 167,9 224,0 276,5 357,3 ❶ Absorbed power (AUTOMATIC 1) kW 26,6 36,9 58,3 75,9 94,0 122,7 ❹ Absorbed power (AUTOMATIC 2) kW 24,5 35,3 55,9 73,3 89,6 121,2 ➋ Absorbed power (SELECT 1-2 AUTOMATIC 3) kW 28,4 39,2 59,8 81,5 97,8 126,7 6,48 6,52 6,11 6,10 6,15 5,75 60 60 63 64 64 69 475 495 4150 4200 4255 4315 TXAEB MODEL ❹ C.O.P. (AUTOMATIC 2) ❸ Sound pressure level dB(A) TXAES MODEL ❶ Nominal cooling capacity (AUTOMATIC 1) kW 70,4 101,8 146,9 195,0 229,5 298,1 ❹ Recovery heating capacity (AUTOMATIC 2) kW 91,7 132,7 198,8 260,4 320,4 409,3 ➋ Nominal heating capacity (SELECT 1-2 AUTOMATIC 3) kW 75,5 106,6 158,6 211,3 261,2 333,8 ❶ Absorbed power (AUTOMATIC 1) kW 25,7 36,2 57,1 76,0 96,8 120,7 ❹ Absorbed power (AUTOMATIC 2) kW 24,5 35,3 55,9 73,3 89,6 121,2 ➋ Absorbed power (SELECT 1-2 AUTOMATIC 3) kW 26,9 37,7 57,5 79,9 95,8 121,3 ❸ Sound pressure level dB(A) 56 56 58 60 60 64 TXAEB-TXAES MODEL 475 495 4150 4200 4255 4315 Scroll/step compressor No. 4/2 4/2 4/2 4/2 4/2 4/2 Circuits No. 2 2 2 2 2 2 Main supply V-ph-Hz 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 DIMENSIONS AND WEIGHTS 475 495 4150 4200 4255 4315 mm 3.353 3.353 3.797 4.902 4.902 4.902 H - Height mm 2.049 2.049 2.049 2.049 2.049 2.100 P - Depth mm 2.062 2.062 2.062 2.062 2.062 2.062 ➎ Weight TXAEB-TXAES kg 1.802 1.896 2.276 3.030 3.190 3.280 L - Width In the following conditions: ❶ Air: 35°C - Water: 7/12°C ❷ Air: 7°C D.B. - 6°C W.B. - Water 40/45°C ❸ At 5 m from the unit, coil side, in free field (Q = 2). ❹ Evaporator water: 7/12°C. Recovery outlet water 45°C - Nominal flow. ➎ Weight of fully accessorised unit when empty. H L P WATER CHILLERS - HEAT PUMPS Macrosystem 70,4÷307,1 kW 75,5÷357,3 kW TXHEY 105÷112 Comby-Flow EXP Range Fan coil systems Radiant Systems Geothermal applications EXPSYSTEMS - Polyvalent ecological watercooled system. Range with hermetic Scroll compressors and R410A refrigerant gas. Construction features Compressor: hermetic, rotary Scroll compressor, complete with thermal protection. Primary side heat exchanger (user), secondary side exchanger (recovery) and disposal unit: adequately insulated stainless steel plates, complete with antifreeze electric heater and water flow differential pressure switch. Control: microprocessor electronic control, iDRHOSS compatible, with Adaptive Function logic. Condensation control: pressure switch valve and bypass solenoid valve. Structure: in galvanised and painted sheet steel with polyester powder coating, complete with soundproofed compressor compartment. Models TXHEY: standard EXPSYSTEMS unit. PUMP unit Primary side (user): pumping group complete with circulation pump, membrane expansion tank, safety valve, water drain valve, manual air bleed valve, pressure gauge. Well/tower side (disposal unit): drain valve and bleed valve. Internal cock for primary side (use) system supply from external network (disposal unit side: well or tower). Secondary side (recovery): pumping group complete with circulation pump, membrane expansion tank, safety valve, water drain valve, manual air bleed valve, pressure gauge. Factory fitted accessories • Digital input for double set-point • 4-20 mA analogue input for shifting set-point. Accessories supplied loose • Water buffer tank • Buffer tank connection pipes • Water filter • Antivibration rubber mountings. • Antifreeze electric heater on the buffer tank. • Remote keyboard with display. • Clock card • Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). • Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. • Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. • GSM 900/1800 modem kit for remote unit management. • Rhoss supervision system for unit monitoring and remote management. P. 71 Microsystem 5,4÷12 kW 6,5÷14,5 kW TXHEY P MODEL 105 107 109 112 ❶ Nominal cooling capacity (AUTOMATIC 1) kW 5,4 6,8 9,3 12,0 ➋ Recovery heating capacity (AUTOMATIC 2) kW 6,7 8,7 11,3 14,5 ❸ Nominal heating capacity (SELECT 1-2 AUTOMATIC 3) kW 6,5 8,2 10,8 13,9 ❶ Total absorbed power (*) (AUTOMATIC 1) kW 1,56 2,12 2,74 3,60 ➋ Total absorbed power (*) (AUTOMATIC 2) kW 2,00 2,83 3,57 4,41 ❸ Total absorbed power (*) (SELECT 1-2 AUTOMATIC 3) kW 2,04 2,88 3,54 4,38 5,80 5,22 5,42 5,67 49,1 51,1 51,3 53,1 1 ➋ C.O.P. (AUTOMATIC 2) ❹ Sound pressure level dB(A) Scroll/step compressor No. 1 1 1 Circuits No. 1 1 1 1 Water buffer tank content KA l 20 20 30 30 ❶ Nominal available head pressure at main exchanger kPa 47,0 54,7 82,2 78,2 ➋ Nominal available head pressure at secondary recovery exchanger kPa 32,4 42,4 72,1 66,7 Main supply V-ph-Hz 230-1-50 230-1-50 400-3+N-50 230-1-50 400-3+N-50 230-1-50 400-3+N-50 In the following conditions: ❶ Condenser water: 30/35°C - Chilled water: 7/12°C. ❷ Chilled water: 7/12°C - Condenser inlet water: 40/45°C ❸ Evaporator water: 10°C - Water flow rate as in summer operation. - Hot water 40/45°C ❹ At 1 m from the unit in free field (Q = 2). KA = Water buffer tank KTC = Connection pipes DIMENSIONS AND WEIGHTS 105 107 109 112 L - Width mm 585 585 660 660 H - Height TXHEY P mm 535 535 535 535 H - Height TXHEY P & KA mm 855 855 855 855 P - Depth mm 520 520 560 560 Weight TXHEY kg 112 118 122 130 Weight KA kg 38 38 43 43 H H KA L P L C KT P WATER CHILLERS - HEAT PUMPS (*) Unit without pump MCAE-MHAE 105÷127 Air-cooled condensing units and reversible condensing units, with axial fans. Range with hermetic compressors and R407C refrigerant gas. Construction features Compressor: hermetic rotary blade compressor complete with thermal protection (mod. 105÷106); hermetic Scroll compressor, complete with thermal protection (mod. 108÷127). Air side heat exchanger: featuring finned coil with copper pipes and aluminium fins, complete with protection grille. Fan: electric axial fan with external rotor, equipped with internal thermal protection and complete with protection grille. Control: microprocessor electronic control. Structure: galvanised and painted sheet steel with epoxy finish, complete with rubber antivibration mountings and cataphoresis-treated sheet steel base (mod. 105÷110), in peraluman with galvanised sheet steel base and soundproofed compressor compartment (mod. 115÷127). Models MCAE: unit designed for cooling only. MHAE: heat pump unit. Accessories supplied loose • Wall-support shelves (mod.105÷110). • Connection cover (mod. 105÷110). • Low pressure switch (mod. 105-106). • Rubber antivibration mountings (mod. 115÷127) • –10°C condensation control. • RS 485 serial interface (mod.115÷127). • RS 232 hardware key (mod. 115÷127). P. 73 Microsystem 5,1÷26,3 kW 6÷29,9 kW 105 106 108 ❶ Nominal cooling capacity kW 5,1 6,3 7,6 8,5 ❶ Absorbed power kW 1,87 2,45 3,00 3,40 105 106 108 110 6,0 7,2 9,0 10,4 MHAE MODEL 110 ➋ Nominal heating capacity kW ❶ Nominal cooling capacity kW 5,1 6,3 7,6 8,5 ➋ Absorbed power kW 1,75 2,10 2,81 3,20 105 106 108 110 54 53 55 54 230-1-50 230-1-50 400-3+N-50 400-3+N-50 MCAE-MHAE MODEL ❸ Sound pressure level Main supply dB(A) V-ph-Hz 230-1-50 105 106 108 110 mm 790 790 830 830 H - Height mm 600 600 900 900 P - Depth mm 300 300 300 300 Weight MCAE kg 59 65 84 85 Weight MHAE kg 60 66 88 90 DIMENSIONS AND WEIGHTS L - Width 115 118 122 127 ❶ Nominal cooling capacity kW 14,7 17,6 21,8 26,3 ❶ Absorbed power kW 4,91 5,65 7,41 8,92 115 118 122 127 15,8 19,9 24,5 29,9 MCAE MODEL MHAE MODEL ➋ Nominal heating capacity kW ❶ Nominal cooling capacity kW 14,7 17,6 21,8 26,3 ➋ Absorbed power kW 5,12 5,63 7,23 8,40 115 118 122 127 49 50 51 52 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 MCAE-MHAE MODEL ❸ Sound pressure level dB(A) Main supply V-ph-Hz 115 118 122 127 mm 1.326 1.326 1.716 1.716 H - Height mm 1.230 1.230 1.230 1.230 P - Depth mm 527 527 615 615 Weight MCAE kg 180 200 260 290 Weight MHAE kg 200 210 280 300 DIMENSIONS AND WEIGHTS L - Width In the following conditions: ❶ Air: 35°C - Suctioned saturated gas: 7°C ❷ Air: 6°C W.B. - Condensazione: 45°C (mod. 105÷110); 50°C (mod. 115÷127) ❸ At 5 m from the unit in free field (Q = 2) H H L L P P WATER CHILLERS - HEAT PUMPS MCAE MODEL CCAM 105÷2130 Remote condensers Remote air condensers with axial fans for direct expansion units operating with R407C refrigerant gas. Construction features Heat exchanger: featuring high efficiency finned coil with copper pipes joined to aluminium fins by mechanical expansion. The unit undergoes pressure and seal tests, guaranteeing a maximum working pressure of 29 bar. The refrigerant circuit connections need brazing. The units are supplied pressurised with nitrogen. Fans: axial fans with external rotor; rotating body of motor and fan blades with aerodynamic configuration that guarantees quiet operation and high performance. The electric fans are also speed-adjustable (by means of the TCEE 105÷2130 evaporator unit PSC accessory) and are protected against overloads by thermal overload switch breakers. Structure: in galvanised and painted sheet steel with epoxy powder coating. • The remote condensers come equipped with a support bracket kit for vertical/horizontal air flow. The support brackets are made from AISI 304 stainless steel for the condensers with fans measuring from 400-500 mm, and in galvanised steel for the condensers with fans measuring from 630-910 mm. • The brackets are of an optimum length for uniform air suction into the coil. • The motors are wired in compliance with VDE 0530/12.84. • IP54 protection, in compliance with DIN 40050. • Electrical panel compliant with IEC standards. Sealed box with IP55 protection, complete with: - Main switch with door interlock;. - Power contactors. - Thermal overload switch; - Indicator lights and remote-controlled alarms. - The electric panel for condensers with fans measuring from 400 to 500 mm is not installed upon delivery. The client is responsible for its installation. Versions The CCAM 105÷2130 range remote condensers are available in 3 construction options that meet the different system requirements concerning ambient noise emission: • Versione “N” Normal (mod. 105-115 excluded); • Version "S" Silenced; • Version “Q” Supersilenced. P. 75 CCAM MODEL 120N 125N 135N 140N 155N 165N 280N 2110N 2130N 23,7 35,0 42,7 51,8 63,9 77,6 97,1 130 161,4 51 48 48 54 50 56 62 64 59 1 VERSION N “Normal” ❶ Nominal heating capacity kW ➋ Sound pressure level dB(A) Refrigerant circuits No. 1 1 1 1 1 1 1 1 Fans No. 1 2 2 2 3 3 2 3 4 Fan nominal air flow m3/h 6.891 11.840 10.322 13.035 15.482 19.553 29.278 45.998 46.879 Rotation speed rpm 1.326 1.059 1.059 1.326 1.059 1.326 1.340 1.340 1.070 ❶ Absorbed power kW 0,78 1,10 1,10 1,56 1,65 2,34 3,80 5,70 5,40 Main supply V-ph-Hz 400/3+N/50 400/3+N/50 CCAM MODEL 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 105S 115S 120S 125S 135S 140S 155S 165S 280S 2110S 2130S VERSION S "Silenced" ❶ Nominal heating capacity kW 8,9 14,9 21,3 33,1 43,2 52,6 64,8 79,0 95,1 127,7 159,8 ➋ Sound pressure level dB(A) 45 42 45 45 42 49 44 51 51 52 52 Refrigerant circuits No. 1 1 1 1 1 1 1 1 1 1 1 Fans No. 1 1 1 2 2 2 3 3 3 4 3 Fan nominal air flow m3/h 3.241 4.700 5.161 8.696 14.342 19.747 21.534 29.647 28.532 38.067 47.411 Rotation speed rpm 1430 842 1.059 842 650 900 650 900 900 900 640 ❶ Absorbed power kW 0,18 0,32 0,55 0,64 0,66 1,38 0,99 2,07 2,07 2,76 2,70 Main supply V-ph-Hz CCAM MODEL 230/1/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50400/3+N/50 105Q 115Q 120Q 125Q 135Q 140Q 155Q 165Q 280Q 2110Q 2130Q 10,3 15,8 23,4 31,4 41,7 52,6 67,8 79,5 98,3 133,2 161,9 33 32 35 35 34 38 40 40 45 43 45 1 VERSION Q “Supersilenced” ❶ Nominal heating capacity kW ➋ Sound pressure level dB(A) Refrigerant circuits No. 1 1 1 1 1 1 1 1 1 1 Fans No. 1 2 2 4 2 4 2 2 4 4 4 Fan nominal air flow m3/h 3.665 3.658 6.789 7.316 10.828 13.089 21.630 19.331 27.493 43.328 43.888 Rotation speed rpm 632 455 614 455 480 624 440 440 650 440 440 ❶ Absorbed power kW 0,15 0,18 0,24 0,36 0,38 0,8 0,66 0,66 1,32 1,32 1,88 Main supply V-ph-Hz Subcooling 3°K - Superheating 25°K. Maximum speed ➋ At 10 m from the unit in free field (Q = 2) In the following conditions: ❶ External temperature: 35°C D.B., 24°C W.B. Dew point: 50°C. Sound pressure level correction for distances other than 10 m Distance (m) Correction dB(A) 2 3 4 5 7 10 15 20 30 40 50 60 80 11 8.5 7 5 2.5 0 –3 –5.5 –9 –11 –12 –14 –16 SYSTEM ACCESSORIES 230/1/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 CEHV CEHP 46÷2791 Cooling towers Cooling towers for water-cooled chillers. Axial fans. Construction features Distribution system: polyvinyl chloride pipes and plastic spray nozzles. Heat exchange package: panel exchanger with plastic cellular structure with large slots. Drop separator: plastic. Fan: axial fan directly coupled with protection grille. Condensation drain pan: in polyester resin strengthened with fibreglass complete with spray protection fins, drain connections, float re-integration and overflow. Structure: in polyester resin strengthened with fibreglass and load-bearing for models of the CEHV range; with hotgalvanised steel sections and with lateral damping using 22 mm sandwich panels in polyester resin strengthened with fibreglass for models of the CEHP-CEHPS range. Models CEHV 46÷639 Cooling towers with load-bearing polyester resin structure strengthened with fibreglass. CEHP 744÷2791 Cooling towers with hot- galvanised steel sections and with lateral damping using 22 mm sandwich panels in polyester resin strengthened with fibreglass. CEHPS 744÷2791 Silenced cooling towers with hotgalvanised steel sections and with lateral damping using 22 mm sandwich panels in polyester resin strengthened with fibreglass. Factory fitted accessories CEHV Range • Inspection pothole. • Electrical anti-freeze heater on condensation drain pan complete with minimum level switch. CEHP – CEHPS range • Manhole. • Dismantable side wall. • Electrical anti-freeze heater on condensation drain pan complete with minimum level switch. P. 77 46 87 105 139 169 203 238 337 395 477 506 599 639 kW 46,5 87,2 104,7 139,5 168,6 203,5 238,4 337,2 395,3 476,7 505,8 598,8 639,5 CEHV MODEL Installed fan electrical power Sound power level ➋ Sound pressure level Main supply kW) 0,55 0,75 0,75 1,1 1,1 1,1 1,1 2,2 2,2 4 4 4 4 dB(A) 74 75 75 75 75 77 77 80 80 83 83 85 85 dB(A) 46 47 47 47 47 49 49 52 52 55 55 57 57 220/380-3-50 V-ph-Hz DIMENSIONS AND WEIGHTS 46 87 105 139 169 203 238 337 395 477 506 599 639 mm 800 1000 1000 1200 1200 1400 1400 1740 1740 2100 2100 2300 2300 H - Height mm 2110 2595 2595 2800 2800 2860 2860 3140 3140 3380 3380 3450 3450 P - Depth mm 800 1000 1000 1200 1200 1400 1400 1740 1740 1900 1900 2100 2100 Empty weight kg 75 85 95 155 170 195 210 380 410 500 525 555 580 Operating weight kg 180 215 285 470 485 755 780 1380 1410 1800 1825 1955 1980 1488 1651 L - Width CEHP MODEL ❶ Nominal heating capacity consumption Installed fan electrical power Sound power level ➋ Sound pressure level Main supply 744 826 878 744,2 825,6 877,9 kW 4 5,5 5,5 7,5 7,5 11 11 11 2X4 2X5,5 2X5,5 2X7,5 2X7,5 2X11 2X11 2X11 dB(A) dB(A) 90 90 92 92 94 94 95 95 93 93 95 95 97 97 98 98 62 62 64 64 66 66 67 67 65 65 67 67 69 69 70 70 2791 kW 971 1070 970,9 1069,8 1186 1256 1756 1948 2139 2366 2512 2791 380/660-3-50 V-ph-Hz DIMENSIONS AND WEIGHTS 1395 1186 1255,8 1395,3 1488,4 1651,2 1755,8 1947,7 2139,5 2366,3 2511,6 2790,7 744 826 878 971 1070 1186 1256 1395 1488 1651 1756 1948 2139 2366 2512 L - Width mm 2025 2025 2365 2365 2875 2875 3370 3370 4080 4080 4750 4750 5770 5770 6770 6770 H - Height mm 3650 3650 3650 3650 3650 3650 3650 3650 3650 3650 3650 3650 3950 3950 3950 3950 P - Depth 2365 mm 2365 2365 2365 2365 2365 2365 2365 2365 2365 2365 2365 2365 2365 2365 2365 Empty weight kg 885 920 965 1000 1115 1165 1220 1270 1630 1700 1790 1860 2125 2225 2375 2475 Operating weight kg 2485 2520 2865 2900 3815 3865 4320 4370 4680 4750 5430 5500 7325 7425 8375 8475 744 826 878 971 1070 1186 1256 1395 1488 1651 1756 1948 2139 2366 2512 2791 kW 744,2 825,6 877,9 CEHPS MODEL ❶ Nominal heating capacity consumption Installed fan electrical power 970,9 1069,8 1186 1255,8 1395,3 1488,4 1651,2 1755,8 1947,7 2139,5 2366,3 2511,6 2790,7 kW 5,5 5,5 7,5 7,5 11 11 11 11 2X5,5 2X5,5 2X7,5 2X7,5 2X11 2X11 2X11 Sound power level dB(A) 79 79 80 80 82 82 83 83 82 82 83 83 85 85 86 86 ➋ Sound pressure level dB(A) 51 51 52 52 54 54 55 55 54 54 55 55 57 57 58 58 744 826 878 971 1070 1186 1256 2791 Main supply V-ph-Hz DIMENSIONS AND WEIGHTS 2X11 380/660-3-50 1395 1488 1651 1756 1948 2139 2366 2512 L - Width mm 2025 2025 2365 2365 2875 2875 3370 3370 4080 4080 4750 4750 5770 5770 6770 6770 H - Height mm 3905 3905 3905 3905 3905 3905 3905 3905 3905 3905 3905 3905 4205 4205 4205 4205 P - Depth mm 2365 2365 2365 2365 2365 2365 2365 2365 2365 2365 2365 2365 2365 2365 2365 2365 Empty weight kg 885 920 965 1000 1115 1165 1220 1270 1630 1700 1790 1860 2125 2225 2375 2475 Operating weight kg 2485 2520 2865 2900 3815 3865 4320 4370 4680 4750 5430 5500 7325 7425 8375 8475 In the following conditions: ❶ Air: 24°C W.B. - Water 35/30°C ➋ At 10 m from the unit in free field (Q = 2). SYSTEM ACCESSORIES ❶ Nominal heating capacity consumption AS 0300÷2500 Pumping groups Pumping groups with buffer tank Versions AS - Standard version with two connections. Construction features Buffer tank: in carbon steel with a capacity of 300, 500, 750, 1000, 1500, or 2500 litres. Water circuit components: single or double centrifugal pump, inlet and outlet shut-off ball valve of each pump, automatic re-integration tap, manual re-integration tap, safety valve, automatic air bleed valve, tank water drain tap, expansion tank with membrane, no-return valve (with double pump only), pressure gauge. The water circuit is insulated with closed cell expanded polyurethane of adequate thickness. Structure: Load-bearing structure made of aluminium sheet metal panelling and base in galvanised and painted steel. Control: electromechanical. Models AS 0300 PU or DPU 1÷5: pumping group equipped with pump on user side (PU) or double pump on user side (DPU). AS 0500 PU or DPU 1÷5: pumping group equipped with pump on user side (PU) or double pump on user side (DPU). AS 0750 PU or DPU 6÷10: pumping group equipped with pump on user side (PU) or double pump on user side (DPU). AS 1000 PU or DPU 6÷10: pumping group equipped with pump on user side (PU) or double pump on user side (DPU). AS 1500 PU or DPU 6÷14: pumping group equipped with pump on user side (PU) or double pump on user side (DPU). AS 2500 PU or DPU 6÷14: pumping group equipped with pump on user side (PU) or double pump on user side (DPU). Accessories supplied loose • Victaulic connections. • Tank antifreeze electric heater with activator. single single single single single single P. 79 MODEL Tank capacity l AS 0300 AS 0500 AS 0750 AS 1000 AS 1500 AS 2500 300 500 750 1000 1500 2500 1-2-3-4-5 Pump model 6-7-8-9-10 6-7-8-9-10-11-12-13-14 l 25 25 25 25 2X25 X25 Expansion tank calibration bar 1,5 1,5 1,5 1,5 1,5 1,5 Safety valve calibration bar Maximum working pressure bar Expansion tank capacity 3,0 3,0 W 1300 1300 1300 1300 1300X2 Water connections (female) Ø (Gas) 21/2” 21/2” 3” 3” 4” Main supply V-pH-Hz AS 1000 AS 1500 Electric heater (optional) DIMENSIONS AND WEIGHTS 1300X2 4” 400-3-50 AS 0300 AS 0500 AS 0750 AS 2500 mm 1504 2044 H - Height mm 1265 1510 1782 P - Depth mm 1120 1200 1900 Weight (*) kg L - Width 231 253 2260 501 528 878 930 PUMP TANK Flow Available head pressure(*) Flow Available head pressure (*) Model litres mc/h Available head pressure (*) Flow m.c.a. mc/h m.c.a. mc/h m.c.a. 1 300 or 500 12 15.5 15 13.5 18 11.1 2 300 or 500 12 19.0 15 17.0 18 14.7 3 300 or 500 21 12.4 24 10.8 30 7.5 4 300 or 500 21 18.2 24 16.6 30 13.3 15.6 5 300 or 500 21 20.4 24 18.8 30 6 750 or 1000 36 17.0 42 16.0 48 14.1 7 750 or 1000 42 27.4 48 25.2 60 20.5 8 750 or 1000 60 17.9 72 15.0 84 12.0 9 750 or 1000 72 20.5 84 17.5 96 15.0 10 750 or 1000 72 29.0 84 26.0 96 23.0 11 1500 or 2500 72 36.0 84 33.0 96 30.0 12 1500 or 2500 108 29.0 120 27.0 138 24.0 13 1500 or 2500 108 34.0 120 32.5 138 30.0 14 1500 or 2500 108 43.1 120 41.0 138 37.0 (*) available head pressure of the pumping group only Diagram with AS pumping group on the outlet Diagram with AS pumping group on return SYSTEM ACCESSORIES (*) Weight of fully accessorised unit when empty. PBHI 0200-0400 Pumping groups with buffer tank for combination with TCHE - THHE - TCEE units with hermetic Scroll compressors (models 155 ÷ 4260). Construction features Buffer tank: in carbon-plated and pre-painted steel sheet, with a 200 or 425 litre capacity. Water circuit components: primary circuit complete with single pump, secondary circuit complete with single standard head pressure pump, buffer tank, expansion tank, safety valve, shut-off valves, tank water charge/drain taps and automatic and manual air bleed valves. Heat exchanger: brazed plate exchanger complete with adjustable flow switch (freecooling version only). Control: electromechanical. Structure: load-bearing structure in galvanised and painted sheet steel with polyester powder coating. The panels are removable in order to allow for easy access to the internal components. Versions • B - Standard version: with single primary and secondary circuit pump (standard head pressure). • F - Freecooling version: fitted with indirect freecooling heat exchanger. Models PBHI 0200 B: standard pumping group for combination with units TCHE-THHE-TCEE - 155-165 PBHI 0400 B: standard pumping group for combination with units TCHE-THHE-TCEE - 280-4260 PBHI 0200 B: freecooling version pumping group for combination with units TCHE-THHE-TCEE - 155-165 PBHI 0400 B: freecooling version pumping group for combination with units TCHE-THHE-TCEE - 280-4260 Factory fitted accessories • single secondary circuit pump with high pressure. • double secondary circuit pump with standard or increased head pressure, including one in standby with automatic activation. • single centrifugal pump with built-in inverter, able to maintain a constant pressure despite variations in system demands. • antifreeze heater 300 W (230V) with activator. Accessories supplied loose • Antivibration rubber mountings. • Flexible tubes for connection to the water chiller/heat pump. P. 81 Macrosystem 50,2÷249 kW PBHI MODEL 0200 0400 Tank capacity l 200 425 Expansion tank capacity l 8 12 Expansion tank calibration kPa 150 150 Safety valve calibration kPa 600 600 Maximum working pressure kPa 600 600 Electric heater (optional) W 300 300 Water connection (female) ∅ (Gas) 2ll F 21/2ll F Sound power level dB(A) 71 74 Main supply V-ph-Hz 400-3+N-50 400-3+N-50 DIMENSIONS AND WEIGHTS L - Width mm 1.340 1.919 H - Height mm 1.206 1.706 P - Depth mm 861 863 PBHI water circuit with single pump on user side FREECOOLING ONLY FREECOOLING VSA VSM PZ R R1 P R FL PZ PHF PZ PZ RA USER UTENZA VE SECONDARY CIRCUIT CIRCUITO SECONDARIO PRIMARY CIRCUIT CIRCUITO PRIMARIO M R R VS SA MAC R1 P PU DPU PUI FL M PZ PHF RA R R1 S SA VE = = = = = = = = = = = = = = VR VS VSA VSM = = = = = S PU SECONDARY CIRCUIT PUMP ACCESSORIES: PBHI water circuit with double pump on user side Primary circuit circulation pump Secondary circuit circulation pump Double secondary circuit circulation pump (factory fitted accessory) Secondary circuit circulation inverter pump (factory fitted accessory) Flow switch Pressure gauge Sockets with internal diameter 6.2 mm Plate heat exchanger for freecooling Buffer tank antifreeze heater (factory fitted accessory) Tap Tap to be fitted by the installer (provided) Water drain/charge tap (outside the buffer tank) Buffer tank Expansion tank calculated to contain the water from the buffer tank only (–10°C ÷ +60°C) Non-return valve Safety valve Automatic air bleed valve Manual air bleed valve Connections FREECOOLING ONLY FREECOOLING VSA PZ R R1 P R FL PZ PHF PZ PZ RA USER VE SECONDARY CIRCUIT CIRCUITO SECONDARIO UTENZA VR PRIMARY CIRCUIT CIRCUITO PRIMARIO M R R VS SA VR MAC PUMP WITH INVERTER Regulation at constant pressure R1 DPU S FREECOOLING ONLY FREECOOLING VSA VSM PZ R R1 P R FL PZ PZ PHF PZ RA USER UTENZA SECONDARY CIRCUIT CIRCUITO SECONDARIO R R PUI VE VS SA M PRIMARY CIRCUIT CIRCUITO PRIMARIO 50 Hz H - Head pressure kPa PBHI water circuit with single inverter pump on user side 25 Hz MA R1 S Q - Capacity m3/h SYSTEM ACCESSORIES VSM Louver: motorized with double fin Wall-mounted fan coil units. Versions Construction features • MPCV - Heating and cooling unit complete with 3-way ON/OFF solenoid valve. • MPCB - Heating-only unit without 3-way valve. Heat exchanger: with finned coil with rapid connections and pipe outlets in several directions. Fan: tangential 3-speed. Louver: motorized with 5-position double fin. Control: microprocessor electronic control. Regulation functions: full auto, cool, dry, fan, autofan, heat. Comfort functions: orienting, swing, timer, sleep, hot start, memory. Advanced functions: economy, lock function, on/off remote control, summer/winter remote control, security control, probe in/out, continuos ventilation, comfort control, occupancy, alarm. Structure: in heat-resistant ABS polymer complete with renewable polypropylene filter, direction-adjustable fins and condensation drain pan with natural drainage. ACCESSORIES ➔ Recessed box with rapid connections, ball valves and flexible connection pipes. ADVANCED CONTROLS ➔ ➔ ➔ ➔ ❖ ❖ Remote control Electronic control panel for wall mounting. Wall-mounted electronic panel Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU). CAN-bus (Controller Area Network) serial interface for the iDRHOSS system. Key: ❖ Factory fitted ➔ Supplied loose P. 83 Unit-System 1,3÷2,5 kW 3,2÷5,4 kW Wall-mounted electronic panel Remote control with bracket for wall installation IDROWALL MODEL ❶ Cooling capacity (total heat) Maximum absorbed power kW kW kW kW kW kW kW m3/h m3/h m3/h dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) W Main supply V-ph-Hz DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight mm mm mm kg ❷ Heating capacity (70°C) ❸ Heating capacity (50°C) Air flow Sound power level ❹ Sound pressure level MAX MED MIN MAX MED MIN MAX MAX MED MIN MAX MED MIN MAX MED MIN 22 1,32 1,11 0,98 3,24 2,89 2,69 1,80 415 352 311 46 41 39 38 33 31 28 33 1,95 1,67 1,45 3,65 3,02 2,54 2,16 457 389 336 47 43 40 39 35 32 33 44 2,48 2,00 1,56 5,41 4,46 3,49 3,15 573 468 363 54 48 42 46 40 34 39 230-1-50 230-1-50 230-1-50 22 960 280 180 12 33 960 280 180 12 44 960 280 180 12 In the following conditions: ❶ Air: 27°C D.B.; 19°C W.B. - Water: 7/12°C. ❷ Air: 20°C - Water: 70/60°C. ❸ Air: 20°C - Water: 50°C, flow rate as in cooling. ❹ At 1 m from air outlet with directionality factor of 2. P L H FAN COIL UNITS Electronic control panel for wall mounting Particular speed selector Floor and ceiling fan coil units STANDARD CONTROLS 10, 13, 20, 23, 33 for 2-pipes-systems; 11, 21,31for 4-pipessystems For wall installation ➔ Panel with speed and summer/winter switch. ➔ Panel with room thermostat and summer/winter switch. ➔ Panel with room thermostat, summer/winter switch, ON/OFF valve signal. ➔ Minimum temperature thermostat (for installation on the machine). ➔ Electronic panel with automatic summer/winter changeover for 2-pipe-systems. ➔ Electronic panel with automatic summer/winter changeover and automatic speed regulation for 2-pipe-systems or 4-pipesystems. For installation on machine. ➔ ❖ Speed switch Versions ADVANCED CONTROLS • MVP - Vertical unit with cabinet equipped with lower air inlet and upper outlet intended for wall installation, on ground with feet, on floor with front air inlet plenum. • MOP - Horizontal unit with cabinet equipped with rear air inlet and front outlet intended for ceiling installation with or without lower air inlet plenum and auxiliary condensation drain pan. Remote control Electronic panel for wall or onboard mounting ➔ Wall-mounted electronic panel For installation on machine. ➔ ❖ Master electronic card with electronic control panel (only for MVP version). ➔ ❖ Master/slave electronic card. ➔ ❖ Temperature probe for hot row. ➔ ❖ ON/OFF valves management module. ➔ Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU). ➔ Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. ➔ Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. Construction features Heat exchanger: with finned coil with left-hand, reversible connections. Fan: tangential 3-speed. Louver: manual with variable opening. Structure: in heat-resistant ABS polymer complete thermo-acoustic insulation, renewable polypropylene direction-adjustable fins and condensation drain pan natural drainage; cover panel in painted sheet metal. non- with filter, with Models ACCESSORIES ➔ ❖ ➔ ❖ ➔ ➔ ➔ ➔ ➔ ➔ ➔ ❖ 3-way ON/OFF solenoid valve for 2-pipe-systems. 3-way ON/OFF solenoid valves for 4-pipe-systems. Air inlet grille. Rear panel for installation with feet. Rear panel for installation with grille. Rear panel. Support feet. Micro-pump for condensation. Auxiliary condensation drain pan. ➔ ➔ Key: ❖ Factory fitted ➔ Supplied loose P. 85 Unit-System 1÷2,9 kW 2,2÷5,7 kW Wall-mounted electronic panel Remote control with bracket for wall installation Electronic panel for wall mounting FREND MODEL ❶ Cooling capacity (total heat) Maximum absorbed power Main supply V-ph-Hz 230-1-50 ❸ Heating capacity (50°C) ❷ Heating capacity hot row Air flow Sound power level ❹ Sound pressure level DIMENSIONS AND WEIGHTS L - Width H - Height H2 - Height of feet and grille P - Depth Weight MOP P 10 1,01 0,88 0,67 2,21 1,91 1,46 1,28 – – – 230 180 120 55 49 41 47 41 33 22 kW kW kW kW kW kW kW kW kW kW m3/h m3/h m3/h dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) W ❷ Heating capacity (70°C) MAX MED MIN MAX MED MIN MAX MAX MED MIN MAX MED MIN MAX MED MIN MAX MED MIN mm mm mm mm kg 10 765 450 100 175 12 11 1,01 0,88 0,67 – – – – 1,46 1,26 0,97 13 1,29 1,12 0,87 2,63 2,25 1,73 1,54 – – – 230 180 120 55 49 41 47 41 33 22 230-1-50 11 20 1,71 1,37 1,06 3,60 2,89 2,24 2,12 – – – 370 260 180 56 50 43 48 42 35 33 21 1,71 1,37 1,06 – – – – 2,39 1,91 1,48 230-1-50 13 230-1-50 20 990 450 100 175 14 765 450 100 175 13 23 2,15 1,65 1,37 4,31 3,44 2,67 2,55 – – – 370 260 180 56 49 40 48 41 32 33 21 23 990 450 100 175 15 MOP with intake grille L H In the following conditions: ❶ Air: 27°C D.B.; 19°C W.B. - Water: 7/12°C. ❷ Air: 20°C - Water: 70/60°C. ❸ Air: 20°C - Water: 50°C, flow rate as in cooling. ❹ At 1 m from air outlet with directionality factor of 2. MVP with intake grille MVP H H2 L P 31 2,35 2,00 1,41 – – – – 3,21 2,72 1,93 33 2,90 2,47 1,73 5,72 4,85 3,42 3,40 – – – 490 380 230 55 50 40 47 42 32 36 230-1-50 31 33 1.215 450 100 175 18 FAN COIL UNITS Frend in MVP version with support feet Floor and ceiling fan coil units Construction features Heat exchanger: with finned coil with left-hand connections reversible to right. Fan: centrifugal 3-speed. Structure: cover panel in painted galvanized sheet metal complete with renewable filter and condensation drain pan with natural drainage; direction-adjustable grilles in heat-resistant ABS polymer. Versions • MVP - Vertical unit with cabinet equipped with lower air inlet and upper outlet for wall mounting or with feet on ground. • MVT - Vertical unit with cabinet equipped with front air inlet and upper outlet for floor installation. • MOP - Horizontal unit with cabinet equipped with rear air inlet and front outlet for ceiling installation. • MOT - Horizontal unit with cabinet equipped with lower air inlet and front outlet for ceiling installation. ACCESSORIES ➔ ❖ ➔ ❖ ➔ ❖ ➔ ➔ ➔ ➔ ❖ ➔ ❖ ➔ ➔ ➔ ➔ Additional water heating coil. Electric heater. Auxiliary condensation drain pan. Manual damper. Motorized damper. Valve and balancing valve. 3-way ON/OFF solenoid valves for 2-pipe-systems. 3-way ON/OFF solenoid valves for 4-pipe-systems. Rear panel. Rear closure panel. Rear closure panel with grille and filter. Support feet with pipe cover. STANDARD CONTROLS For wall installation ➔ Panel with speed and summer/winter switch. ➔ Panel with room thermostat and summer/winter switch. ➔ Panel with room thermostat, summer/winter switch, ON/OFF valve signal and electric heater. ➔ Minimum temperature thermostat (for installation on the machine). ➔ Electronic panel with automatic summer/winter changeover for 2-pipe-systems. ➔ Electronic panel with automatic summer/winter changeover and automatic speed regulation for 2-pipe-systems with electric heater or 4-pipe-systems. For installation on machine ( MVP and MVT versions) ➔ ❖ Panel with speed switch. ➔ ❖ Panel with room thermostat, summer/winter switch and speed switch. ➔ ❖ Minimum temperature thermostat. ➔ ❖ Panel with room thermostat, summer/winter switch, ON/OFF valve signal and electric heater. ➔ ❖ Electronic panel with automatic summer/winter changeover for 2-pipe systems. ➔ ❖ Electronic panel with automatic summer/winter changeover and automatic speed regulation for 2-pipe-systems with electric heater or 4-pipe-systems. Key: ❖ Factory fitted ➔ Supplied loose P. 87 Unit-System 1÷6.9 kW 2.2÷16.5 kW ADVANCED CONTROLS ➔ Remote control ➔ Electronic panel for wall or onboard mounting. ➔ Wall-mounted electronic panel For installation on machine. ➔ ❖ Master electronic card with electronic control panel ( only for MVP - MVT versions). ➔ ❖ Master/slave electronic card. ➔ ❖ Temperature probe for hot row. ➔ ❖ ➔ ➔ ➔ Module for management of ON/OFF valves and electric heater. Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU). Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. Key: ❖ Factory fitted ➔ Supplied loose UNITS: RANGE OF COLOURS: Standard RHOSS special colours (*) PEARL WHITE Bi-colour METALLIC SILVER GREY METALLIC NIGHT BLUE FAN COIL UNITS SATIN-FINISH BRONZE Mono-colour GRAPHITE BLACK METALLIC PURPLE RAL colours (*) Customised colour selection It is possible to choose the desired colour from the RAL range. I.e. RAL 2000 (*)The RHOSS special colours and the RAL colours are available with BI-COLOUR and MONO-COLOUR set-up Wall-mounted electronic panel Remote control with bracket for wall installation Electronic control panel for wall mounting BrioEV MODEL ❶ Cooling capacity (total heat) Maximum absorbed power kW kW kW kW kW kW kW kW kW kW m3/h m3/h m3/h dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) W Main supply V-ph-Hz DIMENSIONS AND WEIGHTS L - Width H - Height Height of feet P - Depth Weight mm mm mm mm kg MOP MOT ❷ Heating capacity (70°C) ❸ Heating capacity (50°C) ❷ Heating capacity additional coil Air flow Sound power level ❹ Sound pressure level MAX MED MIN MAX MED MIN MAX MAX MED MIN MAX MED MIN MAX MED MIN MAX MED MIN 15 0,94 0,74 0,62 2,21 1,73 1,35 1,30 1,34 1,15 0,98 183 138 100 40 32 30 32 24 22 26 20 1,49 1,14 1,09 3,39 2,64 2,34 1,82 1,96 1,64 1,48 238 177 155 41 34 31 33 26 23 23 22 1,92 1,49 1,14 4,30 3,39 2,64 2,52 2,22 1,97 1,64 339 238 177 48 40 32 40 32 24 38 25 2,16 1,95 1,56 5,12 4,39 3,53 2,99 2,78 2,37 1,96 405 339 252 42 37 29 34 29 21 34 30 2,71 2,37 1,71 6,27 5,07 3,85 3,67 3,00 2,56 2,07 483 383 281 46 40 32 38 32 24 44 35 3,26 2,74 1,99 7,22 6,15 4,79 4,24 3,83 3,41 2,89 587 472 365 48 43 35 40 35 27 58 40 3,91 3,19 2,70 8,07 6,58 5,35 4,79 4,03 3,41 3,00 627 474 392 50 43 38 42 35 30 61 50 4,71 3,78 3,23 10,37 7,86 6,81 6,09 5,46 4,55 4,03 916 662 537 56 47 41 48 39 33 95 60 5,92 5,11 4,28 13,33 11,37 10,01 7,84 5,89 5,67 5,58 1.109 882 757 60 54 50 52 46 42 139 70 6,92 5,97 5,51 16,49 14,92 13,42 9,59 6,52 6,20 5,64 1.388 1.171 994 65 61 57 57 53 49 173 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 15 700 583 100 220 25 20 800 583 100 220 31 22 800 583 100 220 31 25 1.000 583 100 220 38 MVP 30 1.000 583 100 220 39 35 1.200 583 100 220 43 40 1.200 583 100 220 44 50 1.500 583 100 220 53 60 1.500 583 100 220 55 70 1.500 583 100 220 57 MVT P H H L In the following conditions: ❶ Air: 27°C D.B.; 19°C W.B. - Water: 7/12°C. ❷ Air: 20°C - Water: 70/60°C. ❸ Air: 20°C - Water: 50°C, flow rate as in cooling. ❹ At 1 m from air outlet with directionality factor of 2. L MVP+feet P P. 89 Construction features Heat exchanger: with finned coil with left-hand connections reversible to right. Centrifugal fan: 3-speed. Structure: covering cabinet in pre-painted sheet metal complete with renewable filter, grilles in ABS polymer and condensation drain pan with natural drainage. Versions • MVP - Vertical unit with cabinet equipped with lower air inlet and upper outlet for wall mounting or with feet on ground. • MVT - Vertical unit with cabinet equipped with front air inlet and upper outlet for floor installation. • MOP - Horizontal unit with cabinet equipped with rear air inlet and front outlet for ceiling installation. • MOT - Horizontal unit with cabinet equipped with lower air inlet and front outlet for ceiling installation. ACCESSORIES ➔ ❖ ➔ ❖ ➔ ❖ ➔ ➔ ➔ ➔ ❖ ➔ ❖ ➔ ➔ ➔ ➔ Additional water heating coil. Electric heater. Auxiliary condensation drain pan. Manual damper. Motorized damper. Valve and balancing valve. 3-way ON/OFF solenoid valves for 2-pipe-systems. 3-way ON/OFF solenoid valves for 4-pipe-systems. Rear panel. Rear closure panel. Rear closure panel with grille and filter. Support feet with pipe cover. STANDARD CONTROLS For wall installation ➔ Panel with speed and summer/winter switch. ➔ Panel with room thermostat and summer/winter switch. ➔ Panel with room thermostat, summer/winter switch, ON/OFF valve signal and electric heater. ➔ Minimum temperature thermostat (for installation on the machine). ➔ Electronic panel with automatic summer/winter changeover for 2-pipe-systems. ➔ Electronic panel with automatic summer/winter changeover and automatic speed regulation for 2-pipe-systems with electric heater or 4-pipe-systems. For installation on machine ( MVP and MVT versions) ➔ ❖ Panel with speed switch. ➔ ❖ Panel with room thermostat, summer/winter switch and speed switch. ➔ ❖ Minimum temperature thermostat. ➔ ❖ Panel with room thermostat, summer/winter switch, ON/OFF valve signal and electric heater. ➔ ❖ Electronic panel with automatic summer/winter changeover for 2-pipe systems. ➔ ❖ Electronic panel with automatic summer/winter changeover and automatic speed regulation for 2-pipe-systems with electric heater or 4-pipe-systems. Key: ❖ Factory fitted ➔ Supplied loose FAN COIL UNITS Floor and ceiling fan coil units Unit-System 1,1÷7,2 kW 2,4÷17,4kW ADVANCED CONTROLS ➔ Electronic panel for wall or onboard mounting. Wall-mounted electronic panel For installation on machine. ➔ ❖ Master electronic card with electronic control panel ( only for MVP - MVT versions). ➔ ❖ Master/slave electronic card. ➔ ❖ Temperature probe for hot row. ➔ ❖ Module for management of ON/OFF valves and electric heater. ➔ Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU). ➔ Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. ➔ Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. ➔ Key: ❖ Factory fitted ➔ Supplied loose YardyEV MOP-MOT-MVP-MVT MODEL ❶ Cooling capacity MAX kW (total heat) MED kW MIN kW ❷ Heating capacity (70°C) MAX kW MED kW MIN kW ❸ Heating capacity (50°C) MAX kW ❷ Heating capacity MAX kW additional coil MED kW MIN kW Air flow MAX m3/h MED m3/h MIN m3/h Sound power level MAX dB(A) MED dB(A) MIN dB(A) ❹ Sound pressure level MAX dB(A) MED dB(A) MIN dB(A) Maximum absorbed power W Main supply V-ph-Hz DIMENSIONS AND WEIGHTS L - Width H - Height Height of feet P - Depth Weight MOP mm mm mm mm kg MOT 15 1,02 0,87 0,62 2,40 2,02 1,35 1,41 1,40 1,16 0,98 209 163 100 43 35 26 35 27 18 32 20 1,71 1,32 1,09 3,74 2,81 2,34 2,20 2,16 1,72 1,48 288 207 155 44 35 28 36 27 20 30 22 1,92 1,49 1,14 4,30 3,39 2,64 2,52 2,22 1,97 1,64 339 238 177 48 40 32 40 32 24 38 25 2,42 1,95 1,56 5,66 4,39 3,53 3,31 3,01 2,56 2,07 484 339 252 48 38 30 40 30 22 45 35 2,96 2,49 2,00 6,51 5,45 4,31 3,82 3,24 2,78 2,30 547 434 329 50 43 36 42 35 28 54 40 3,61 2,74 2,38 8,32 6,15 5,26 4,88 3,92 3,41 3,02 676 472 390 51 43 38 43 35 30 72 45 4,12 3,19 2,89 8,88 6,58 6,08 5,26 3,93 3,41 3,04 681 474 431 52 43 41 44 35 33 70 55 5,23 4,27 3,78 11,70 9,32 7,86 6,83 6,11 5,16 4,55 1.077 802 662 58 52 47 50 44 39 115 65 6,34 5,28 4,28 14,23 11,72 10,01 8,36 6,31 5,80 5,58 1.235 948 757 62 56 50 54 48 42 161 75 7,19 5,97 5,51 17,37 14,92 13,42 10,08 6,81 6,20 5,64 1.480 1.171 994 66 61 57 58 53 49 184 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 15 700 570 100 220 25 20 800 570 100 220 31 22 800 570 100 220 31 25 1.000 570 100 220 38 35 1.000 570 100 220 39 40 1.200 570 100 220 43 45 1.200 570 100 220 44 55 1.500 570 100 220 55 65 1.500 570 100 220 55 75 1.500 570 100 220 57 MVT MVP P H H L In the following conditions: ❶ Air: 27°C D.B.; 19°C W.B. - Water: 7/12°C. ❷ Air: 20°C - Water: 70/60°C. ❸ Air: 20°C - Water: 50°C, flow rate as in cooling. ❹ At 1 m from air outlet with directionality factor of 2. P MVP+feet L P. 91 Construction features Heat exchanger: with finned coil with left-hand connections reversible to right. Centrifugal fan: 3-speed for versions IVP, IVF and IOP; 5speed for COP version. Structure: in galvanized sheet steel, complete with condensation drain pan with natural drainage and renewable filter (class G2 for COP version). Versions • IVP - Recessed vertical unit equipped with lower air inlet and upper outlet for wall installation. • IVF - Recessed vertical unit equipped with lower air inlet and front outlet for wall installation. • IOP - Recessed horizontal unit equipped with rear air inlet and front outlet for ceiling installation. • COP - Ductable recessed horizontal unit equipped with rear air inlet and front outlet for ceiling installation. ACCESSORIES ➔ ❖ ➔ ❖ ➔ ❖ ➔ ➔ ➔ ❖ ➔ ❖ ➔ ➔ ➔ ➔ ➔ ➔ ➔ ➔ ➔ Additional water heating coil. Electric heater. Auxiliary condensation drain pan. Motorized damper. Valve and balancing valve. 3-way ON/OFF solenoid valves for 2-pipe-systems. 3-way ON/OFF solenoid valves for 4-pipe-systems. Straight outlet connection. 90° outlet connection. 90° inlet connection. Telescopic outlet/inlet connection. Inlet grille with filter. Outlet grille. Cover panel with grilles (only IVF and IOP). Inlet plenum with circular nozzles. Outlet plenum with circular nozzles. STANDARD CONTROLS For wall installation ➔ Panel with speed and summer/winter switch. ➔ Panel with room thermostat and summer/winter switch. ➔ Panel with room thermostat, summer/winter switch, ON/OFF valve signal and electric heater. ➔ Minimum temperature thermostat (for installation on the machine). ➔ Electronic panel with automatic summer/winter changeover for 2-pipe-systems. ➔ Electronic panel with automatic summer/winter changeover and automatic speed regulation for 2-pipe-systems with electric heater or 4-pipe-systems. ADVANCED CONTROLS ➔ Remote control Electronic control panel for wall mounting. ➔ Wall-mounted electronic panel For installation on machine. ➔ ❖ Master/slave electronic card. ➔ ❖ Temperature probe for hot row. ➔ ❖ Module for management of ON/OFF valves and electric heater. ➔ Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU). ➔ Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. ➔ Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. ➔ Key: ❖ Factory fitted ➔ Supplied loose FAN COIL UNITS Ductable and recessed fan coil units. Wall-mounted electronic panel Electronic control panel for wall mounting. YardyEV IOP-IVP-IVF MODEL ❶ Cooling capacity MAX (total heat) MED MIN ❷ Heating capacity (70°C) MAX MED MIN ❸ Heating capacity (50°C) MAX ❷ Heating capacity MAX additional coil MED MIN Air flow MAX MED MIN Sound power level MAX MED MIN ❹ Sound pressure level MAX MED MIN Maximum absorbed power kW kW kW kW kW kW kW kW kW kW m3/h m3/h m3/h dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) W Main supply V-ph-Hz DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight mm mm mm kg IOP 15 1,02 0,87 0,62 2,40 2,02 1,35 1,41 1,40 1,16 0,98 209 163 100 43 35 26 35 27 18 32 20 1,71 1,32 1,09 3,74 2,81 2,34 2,20 2,16 1,72 1,48 288 207 155 44 35 28 36 27 20 30 22 1,92 1,49 1,14 4,30 3,39 2,64 2,52 2,22 1,97 1,64 339 238 177 48 40 32 40 32 24 38 25 2,42 1,95 1,56 5,66 4,39 3,53 3,31 3,01 2,56 2,07 484 339 252 48 38 30 40 30 22 45 35 2,96 2,49 2,00 6,51 5,45 4,31 3,82 3,24 2,78 2,30 547 434 329 50 43 36 42 35 28 54 40 3,61 2,74 2,38 8,32 6,15 5,26 4,88 3,92 3,41 3,02 676 472 390 51 43 38 43 35 30 72 45 4,12 3,19 2,89 8,88 6,58 6,08 5,26 3,93 3,41 3,04 681 474 431 52 43 41 44 35 33 70 55 5,23 4,27 3,78 11,70 9,32 7,86 6,83 6,11 5,16 4,55 1.077 802 662 58 52 47 50 44 39 115 65 6,34 5,28 4,28 14,23 11,72 10,01 8,36 6,31 5,80 5,58 1.235 948 757 62 56 50 54 48 42 161 75 7,19 5,97 5,51 17,37 14,92 13,42 10,08 6,81 6,20 5,64 1.480 1.171 994 66 61 57 58 53 49 184 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 15 450 545 212 22 20 550 545 212 28 22 550 545 212 28 25 750 545 212 35 35 750 545 212 36 40 950 545 212 39 45 950 545 212 40 55 1.250 545 212 48 65 1.250 545 212 50 75 1.250 545 212 52 IVP IVF H P H H L P In the following conditions: ❶ Air: 27°C D.B.; 19°C W.B. - Water: 7/12°C. ❷ Air: 20°C - Water: 70/60°C. ❸ Air: 20°C - Water: 50°C, flow rate as in cooling. ❹ At 1 m from air outlet with directionality factor of 2. L P L P. 93 Unit-System 1,1÷7,2 kW 2,4÷17,4 kW Electronic control panel for wall mounting. Wall-mounted electronic panel YardyEV COP with inlet and outlet plenum with circular nozzles Maximum absorbed power kW kW kW kW kW kW kW kW kW kW kW kW kW kW kW kW kW kW kW kW m3/h m3/h m3/h m3/h m3/h dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) W Main supply V-ph-Hz DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight mm mm mm kg ❷ Heating capacity (70°C) ❸ Heating capacity (50°C) ❷ Heating capacity additional coil Air flow Sound power level ❹ Sound pressure level V IV III II I V IV III II I V IV III II I V IV III II I V IV III II I V IV III II I V IV III II I 33 3,46 3,28 2,98 2,50 2,32 7,64 7,25 6,58 5,51 5,11 4,48 4,24 3,85 3,23 3,00 3,83 3,64 3,31 2,78 2,58 695 645 560 440 400 60 58 55 49 47 52 50 47 41 39 100 44 5,38 4,53 4,16 3,83 3,41 11,19 9,44 8,66 7,96 7,10 6,63 5,60 5,13 4,72 4,21 5,57 4,72 4,31 3,97 3,54 970 765 685 615 535 66 62 60 58 55 58 54 52 50 47 120 66 6,17 5,96 5,61 5,33 4,99 13,57 13,1 12,3 11,7 11,0 7,95 7,66 7,23 6,86 6,44 6,07 5,85 5,50 5,24 4,91 1.195 1.130 1.040 970 890 65 63 61 60 59 57 55 53 52 51 150 230-1-50 230-1-50 230-1-50 33 750 545 212 35 44 950 545 212 40 66 1.250 545 212 52 In the following conditions: ❶ Air: 27°C D.B.; 19°C W.B. - Water: 7/12°C. Available head pressure 0 Pa. ❷ Air: 20°C - Water: 70/60°C. Available head pressure 0 Pa. ❸ Air: 20°C - Water: 50°C, flow rate as in cooling; max. speed Available head pressure 0 Pa. ❹ At 1 m from air outlet with directionality factor of 2, non-ducted unit. FAN COIL UNITS MODEL YardyEV COP ❶ Cooling capacity (total heat) COP P H L Cassette-type fan coil units Construction features Fan coils: cassette-type for installation in false ceilings, with air inlet and outlet directly into the room. Heat exchanger: with finned coil. Fan: 3-speed. Structure: load-bearing, in galvanised sheet metal, complete with condensation drain pump (up to 200 mm above the unit). Air supply panel: in ABS polymer with manually adjustable outlet fins, inlet grille and renewable filter. Versions • Standard - for 2-pipes-systems. • B4 - for 4-pipes-systems. • REL - for 2-pipes-systems supplementary electric heater. Accessories supplied loose • • • • • • 3-way ON/OFF solenoid valve for 2-pipe-systems. 3-way ON/OFF solenoid valves for 4-pipe-systems. Micro-pump for condensation. Auxiliary condensation drain pan. Outlet nozzle lock. Photocatalytic and passive electrostatic filter. STANDARD CONTROLS For wall installation ➔ Panel with speed and summer/winter switch. ➔ Panel with room thermostat, summer/winter switch, ON/OFF valve signal and electric heater. ➔ Electronic panel with automatic summer/winter changeover for 2-pipe-systems. ➔ Electronic panel with automatic summer/winter changeover and automatic speed regulation for 2-pipe-systems with electric heater or 4-pipe-systems. ADVANCED CONTROLS ➔ Remote control Electronic control panel for wall mounting. ➔ Wall-mounted electronic panel For installation on machine. ➔ Master/slave electronic card. ➔ Temperature probe for hot row. ➔ Module for management of ON/OFF valves and electric heater. ➔ Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU). ➔ Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. ➔ Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. ➔ Key: ➔ Supplied loose P. 95 Unit-System 2,4÷10 kW 5,6÷23,8 kW Wall fitted panel Infrared remote control with bracket for wall installation UTNC-EV MODEL ❶ Cooling capacity (total heat) UTNC/B4 UTNC-UTNC/REL 25 40 1,90 4,00 1,43 2,85 1,23 1,90 – 7,03 – 5,94 – 3,47 – 4,19 1,77 – 1,34 – 1,16 – – 2,5 – – 662 698 450 490 360 310 49 54 43 45 40 34 41 46 35 37 32 26 70 90 UTNC/B4 UTNC-UTNC/REL 40 50 3,23 4,70 2,42 3,5 1,61 2,85 – 10,42 – 7,58 – 6,4 – 6,03 4,27 – 3,20 – 2,14 – – 2,5 – – 698 850 490 601 310 472 55 59 45 50 33 44 47 51 37 42 25 36 85 100 UTNC/B4 UTNC-UTNC/REL UTNC-UTNC/REL UTNC-UTNC/REL 50 60 85 110 4,00 6,30 7,60 10,00 3,05 4,50 5,10 7,10 2,50 3,40 3,17 3,90 – 13,76 18,36 23,77 – 9,99 12,6 17,03 – 7,43 7,54 9,35 – 8,12 10,80 12,90 4,64 – – – 3,51 – – – 2,74 – – – – – – – – 3,0 3,0 3,0 850 1.019 1.217 1.685 601 731 871 1.134 472 540 529 641 58 49 56 63 50 41 49 55 42 36 41 42 50 41 48 55 42 33 41 47 34 28 33 34 95 90 120 200 UTNC/B4 110 8,45 6,29 3,53 – – – – 7,92 6,95 4,49 – – 1.685 1.134 641 63 55 42 55 47 34 200 Maximum absorbed power kW kW kW kW kW kW kW kW kW kW kW kW m3/h m3/h m3/h dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) W Main supply V-ph-Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 DIMENSIONS AND WEIGHTS L2/H2/P2 - Width/Height/Depth L/H/P - Width/Height/Depth Weight UTNC - UTNC/REL Weight UTNC/B4 Air supply panel weight mm mm kg kg kg 25 25 40 40 50 50 60 85 110 110 575/298/575 575/298/575 575/298/575 575/298/575 575/298/575 575/298/575 825/298/825 825/298/825 825/298/825 825/298/825 720/30/720 720/30/720 720/30/720 720/30/720 720/30/720 720/30/720 960/30/960 960/30/960 960/30/960 960/30/960 18,5 – 20 – 20 – 37 39 39 – – 18,5 – 20 – 20 – – – 40 4 4 4 4 4 4 6 6 6 6 ❷ Heating capacity (70°C) ❸ Heating capacity (50°C) ❷ Heating capacity additional coil B4 Electric heater REL Electric heater REL Air flow Sound power level ❹ Sound pressure level MAX MED MIN MAX MED MIN MAX MAX MED MIN 230-1-50 V 400-3-50 V MAX MED MIN MAX MED MIN MAX MED MIN UTNC-UTNC/REL 25 2,40 1,80 1,55 5,55 4,38 3,85 3,16 – – – 1,5 – 662 450 360 49 38 34 41 30 26 70 In the following conditions: ❶ Air: 27°C D.B.; 19°C W.B. - Water: 7/12°C. ❷ Air: 20°C - Water: 70/60°C. ❸ Air: 20°C - Water: 50°C, flow rate as in cooling. ❹ At 1 m from air outlet with directionality factor of 2. L2 P2 H2 P L FAN COIL UNITS Electronic control panel for wall mounting VTNC 25÷85 Cassette-type fan coil units Versions Standard - for 2-pipes-systems. Construction features Fan coils: cassette-type for installation in false ceilings, with air inlet and outlet directly into the room. Heat exchanger: with finned coil. Fan: 3-speed. Structure: load-bearing, in galvanised sheet metal, complete with condensation drain pump (up to 200 mm above the unit) and auxiliary condensation drain pan. Air supply panel: in ABS polymer (RAL9010) with motorised outlet fins adjustable in various positions, inlet grille and renewable filter. Remote control: supplied as standard Accessories supplied loose • 3-way ON/OFF solenoid valve for 2-pipe-systems. • Outlet nozzle lock. STANDARD CONTROLS For wall installation ➔ Electronic control panel for wall mounting. P. 97 Unit-System 2,5÷8,5 kW 5,4÷20,4 kW VTNC MODEL ❶ Cooling capacity (total heat) Maximum absorbed power kW kW kW kW kW kW kW m3/h m3/h m3/h dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) W Main supply V-ph-Hz ❷ Heating capacity (70°C) ❸ Heating capacity (50°C) Air flow Sound power level ❹ Sound pressure level MAX MED MIN MAX MED MIN MAX MAX MED MIN MAX MED MIN MAX MED MIN DIMENSIONS AND WEIGHTS L2/H2/P2 - Width/Height/Depth L/H/P - Width/Height/Depth Weight VTNC Air supply panel weight mm mm kg kg VTNC 25 2,50 2,29 2,01 5,81 5,33 4,66 3,63 603 524 416 49 46 40 41 38 32 69 P VTNC 30 3,06 2,79 2,47 5,70 5,21 4,61 4,09 680 599 468 54 51 44 46 43 36 69 L E R I VTNC 50 4,83 4,57 3,95 10,45 9,90 8,55 5,99 914 842 756 62 59 56 54 51 48 87 N I M VTNC 60 5,75 4,38 3,13 13,26 10,10 7,22 8,65 1401 1176 967 59 50 43 51 42 35 118 VTNC 85 7,83 7,13 5,92 19,61 17,86 14,83 11,36 1720 1585 1333 62 60 58 54 52 50 162 Y R A 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 25 580/254/580 650/30/650 21 3 30 580/254/580 650/30/650 21 3 50 580/254/580 650/30/650 21 3 60 840/240/840 950/40/950 36 6 85 840/310/840 950/40/950 40 6 In the following conditions: ❶ Air: 27°C D.B.; 19°C W.B. - Water: 7/12°C. ❷ Air: 20°C - Water: 70/60°C. ❸ Air: 20°C - Water: 50°C, flow rate as in cooling. ❹ At 1 m from air outlet with directionality factor of 2. L2 P2 H2 P L FAN COIL UNITS Remote control UTNB 011÷017 UTNB with air inlet via inlet panelling and multi-duct outlet Wall-mounted electronic panel Electronic control panel for wall mounting Ductable terminal air handling units in sections Construction features Air handling unit: in modules for installation in false ceiling, with ducting or panelling (29 cm in height). Heat exchanger: with finned coil with right-hand connections reversible to left. Fan: centrifugal 3-speed (IP44). Structure: load-bearing in galvanized sheet metal complete with thermo-acoustic insulation, renewable filter, connection for attachment to inlet duct and condensation drain pan with natural drainage. STANDARD CONTROLS For wall installation ➔ Panel with speed and summer/winter switch. ➔ Panel with room thermostat, summer/winter switch, ON/OFF valve signal. ➔ Control panel for modulating valves in 4-pipe systems. ➔ Humidistat panel. ➔ Electronic panel with automatic summer/winter changeover for 2-pipe-systems. ➔ Electronic panel with automatic summer/winter changeover and automatic speed regulation for 2-pipe-systems with electric heater or 4-pipe-systems. ADVANCED CONTROLS Accessories supplied loose • Additional water heating coil. • Inlet/outlet plenum (KPAM). • Electric coil module of 1.5-3-4.5 kW (KBAE). • Plenum with steam humidifier (KUMI). • Outlet nozzles module (KBOM). • Inlet panelling. • Solid panelling. • Outlet panelling. ➔ Remote control Electronic control panel for wall mounting. ➔ Wall-mounted electronic panel For installation on machine. ➔ Master/slave electronic card. ➔ Temperature probe for hot row. ➔ Module for management of ON/OFF valves and electric heater. ➔ Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU). ➔ Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. ➔ Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. ➔ Key: ➔ Supplied loose P. 99 Unit-System 4,1÷10,5 kW 10,3÷23 kW 100 290 Humidistat panel for KUMI 99 0 130 660 (*) 290 290 UTNB Base unit KBOM Outlet nozzles module KUMI Plenum with humidifier 011 2R 011 4R 011 6R 014 2R 014 4R 014 6R 017 2R 017 4R ❶ Nominal cooling capacity kW 4,11 6,76 7,78 4,82 8,23 9,64 5,14 8,92 10,52 ➋ Nominal heating capacity kW 10.35 (•) (•) 12.66 18.83 (•) 13.76 20.78 23.04 ➋ Nominal heating capacity additional coil kW 10,02 10,02 10,02 12,37 12,37 12,37 13,49 13,49 13,49 Air flow MAX m3/h 1.100 1.100 1.100 1.480 1.480 1.480 1.680 1.680 1.680 MED m3/h 990 990 990 1.260 1.260 1.260 1.440 1.440 1.440 MIN m3/h 850 850 850 1.100 1.100 1.100 1.200 1.200 1.200 6 3 0 16 4 0 23 7 0 dB(A) 41 41 41 47 47 47 50 50 50 MED dB(A) 40 40 40 44 44 44 46 46 46 MIN dB(A) 38 38 38 41 41 41 41 41 41 165 165 165 205 205 205 245 245 245 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 UTNB MODEL ➍ Available head pressure at maximum speed Pa ❸ Sound pressure level MAX ❶/➋ Absorbed power W Main supply V-ph-Hz 017 6R 011 2R 011 4R 011 6R 014 2R 014 4R 014 6R 017 2R 017 4R 017 6R L - Width mm 990 990 990 990 990 990 990 990 990 H - Height mm 290 290 290 290 290 290 290 290 290 KPAM - Depth mm 290 290 290 290 290 290 290 290 290 UTNB - Depth mm 738 738 738 738 738 738 738 738 738 KBAE - Depth mm 130 130 130 130 130 130 130 130 130 KUMI - Depth mm 290 290 290 290 290 290 290 290 290 KBOM - Depth mm 100 100 100 100 100 100 100 100 100 Weight UTNB kg 38 42 46 38 42 46 40 44 48 DIMENSIONS AND WEIGHTS In the following conditions: ❶ Air: 27°C D.B.; 19°C W.B. - Water: 7/12°C. Maximum speed ❷ Air: 20°C - Water: 70/60°C. Maximum speed ❸ At 3 m from the point of air outlet, with open outlet. ➍ With filter and coil. (•) Not to be used with water at 70°C, capacities at different temperatures are shown in the technical catalogue. (*) Unit dimensions in combination with KPAM plenum TERMINAL UNITS KPAM Inlet/outlet plenum KBAE Electric coil module UTNA 015÷150 Wall-mounted electronic panel Base composition Electronic control panel for wall mounting. BA Coil module SV Fan module Ductable terminal air handling units in sections Construction features Air handling unit: in sections for horizontal installation either with or without ducting. Structure: in galvanized steel sheet metal, with fully removable pre-painted sheet metal panelling, complete with self-extinguishing thermo-acoustic insulation. Module BA 2R, BA 4R, BA 6R: complete with pleated filter in 2 sections with degree of efficiency G3, can be slid out in all directions; heat exchanger with finned coil, with 2 or 4 or 6 rows with reversible right-hand connections; condensation drain pan with natural drainage. Fan module SV: complete with centrifugal fan with double inlet with motor (IP55) directly coupled, 3-speed for models 015÷038; 2-speed for model 051; with 4-pole single speed motor (4/6 or 4/8 poles on request) coupled by means of trapezoidal belt and variable pulley for models 078-150. Electrical board: standard for models 051÷150; accessory for models 015÷038. Accessory modules • Inlet/outlet plenum with pre-cut side outlets (PMA). • Plenum with absorbent cartridge silencer to be placed for inlet or outlet (SIL). • Plenum with steam humidifier and external electric generator (MUV - PRV). Accessories supplied loose • Additional water heating coil to be inserted in module BA. • Supplementary electric heater from 1.5 kW to 36 kW, to be inserted in module BA. • Droplet eliminator for models 078÷150, to be inserted in module BA. • Combined fresh air damper (max 25%) and re-circulation, to be attached to the PMA inlet plenum. • Solid pre-cut panel for connection to duct, to be attached to the PMA inlet plenum. • Panel with rectangluar outlet nozzle with double row of adjustable fins, to be attached to PMA outlet plenum. • Panel with circular nozzles, to be attached to PMA inlet/outlet plenum (only for models 015÷051). • Manual control for KSER damper. • Electrical panel in waterproof box (IP55 for UTNA 015÷038). • Humidistat panel for humidifier. STANDARD CONTROLS For wall installation ➔ Panel with speed and summer/winter switch. ➔ Panel with room thermostat, summer/winter switch, ON/OFF valve signal. ➔ Control panel for modulating valves in 4-pipe systems. ➔ Humidistat panel. ➔ Electronic panel with automatic summer/winter changeover for 2-pipe-systems. ➔ Electronic panel with automatic summer/winter changeover and automatic speed regulation for 2-pipe-systems with electric heater or 4-pipe-systems. ADVANCED CONTROLS ➔ Remote control Electronic control panel for wall mounting. ➔ Wall-mounted electronic panel For installation on machine. ➔ Master/slave electronic card. ➔ Temperature probe for hot row. ➔ Module for management of ON/OFF valves and electric heater. ➔ Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU). ➔ Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. ➔ Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. ➔ Key: ❖ Factory fitted ➔ Supplied loose P. 101 Unit-System 7,2÷108 kW 11,3÷174 kW Complete composition KSER Damper P KB2R Additional heating coil SIL Plenum with silencer L PRV Steam producer H KPBC Panel with circular nozzles BA Coil module MUV Plenum with humidifier SV Fan module Humidistat panel KPBM Panel with outlet nozzle PMA Inlet/outlet plenum UTNA MODEL 015 020 029 038 051 078 107 130 150 ➋ Nominal heating capacity additional coil BA 2R/KB2R kW 11,3 14,2 20,7 25,8 35,2 57,5 82,6 92,7 106,0 ❶ Nominal cooling capacity BA 4R kW 7,2 8,8 13,9 17,3 21,4 41,8 60,6 67,8 77,1 ➋ Nominal heating capacity BA 4R kW 18,5 24,0 33,7 42,8 57,6 92,9 133,0 152,0 174,0 ❶ Nominal cooling capacity BA 6R kW 9,9 12,5 17,9 22,4 30,9 55,6 82,7 94,4 108,0 ➋Nominal heating capacity BA 6R kW (•) (•) (•) (•) (•) (•) (•) (•) (•) 230V-1ph-50Hz kW 1,5-3-4,5 3-4,5-6 4,5-6-9 6-9-12 – – – – – 400V-3ph-50Hz kW 1,5-3-4,5 3-4,5-6 4,5-6-9 6-9-12 9-12-18 12-18-24 18-24-36 18-24-36 24-36 Electric heater power Air flow MAX m3/h 1.800 2.640 3.220 4.260 6.120 MED m3/h 1.370 2.240 2.400 3.500 – – – – MIN m3/h 1.060 1.480 1.560 2.850 4.390 – – – – 90 90 90 90 130 170 160 145 140 61,9 ➍ Available head pressure at maximum speed Pa ❸ Sound pressure level 8.580 (*) 11.770 (*) 14.300 (*) 16.500 (*) – MAX dB(A) 50,9 55,6 54,9 59,8 61,5 59,7 61,7 65,4 MED dB(A) 44,3 50,2 48,3 55,7 – – – – – MIN dB(A) 37,1 42,1 38,7 51,4 54,4 – – – – ❶/➋ Absorbed power W 370 700 700 1.250 1.850 1.500 1.500 2.200 3.000 Main supply V-ph-Hz 230-1-50 230-1-50 230-1-50 230-1-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 015 020 029 038 051 078 107 130 150 mm 928 928 1.228 1.228 1.328 1.658 2.058 2.058 2.058 H - Height mm 398 398 463 518 568 768 918 918 1.018 PMA - Depth mm 370 370 435 490 540 740 890 890 990 BA - Depth mm 645 645 645 645 645 910 910 910 910 SV - Depth mm 370 370 435 490 490 1.040 1.040 1.040 1.040 SIL-MUV - Depth mm 960 960 960 960 960 1.040 1.040 1.040 1.040 ➎ Weight UTNA kg 51 51 68 71 79 140 200 200 220 DIMENSIONS AND WEIGHTS L - Width In the following conditions: ❶ Air: 27°C D.B.; 19°C W.B. - Water: 7/12°C. Maximum speed ❷ Air: 20°C - Water: 70/60°C. Maximum speed ❸ At 3 m from the point of air outlet, with open outlet. ➍ 4-row coil (BA 4R) and filter.. ➎ Empty weight BA 6R. (•) Not to be used with water at 70°C, capacities at different temperatures are shown in the technical catalogue. (*) Belt transmission with variable ratio. TERMINAL UNITS PMA Inlet/outlet plenum UTNV 030÷150 Air conditioning and ventilation terminal units. Construction features Air conditioning and ventilation unit: for vertical installation with or without ducting. Structure: packaged composed of treatment section and fan assembly with load-bearing frame in double-chamber extruded aluminium profiles with concealed screws, corner joints in black nylon, glass reinforced. Removable panelling in double sheet metal, in galvanized steel on the inside and pre-painted with protection film on the outside, with expanded polyurethane inserted (density 45 kg/m3) and total thickness of 25 mm. Base with extruded aluminium profiles. Treatment section composed of: pleated renewable multisection filters with degree of efficiency G3, can be extracted from front (or from side with KEF accessory), heat exchanger with finned coil with 2-4-6 rows with connections on right or left on request and galvanized steel condensation drain pan with natural drainage. On request the water connections can be located on the right or left side of the unit. Electric fan assembly: with upper or front outlet composed of double inlet centrifugal fans with forward rotors with antivibration joint on pressing mouth, tri-phase motor (IP55), variable pulley and trapezoidal belt drive (up to model 080), anti-vibration rubber mountings. Versions • M - Single-phase motor for models 030-050 with adjustable pulley. • T6 - Tri-phase 4/6-pole motor with adjustable pulley. • T8 - Tri-phase 4/8-pole motor with adjustable pulley. • E - Treatment section with side opening for fresh air inlet. • B2R - Additional coil with 2 rows for 4-pipe systems for UTNV 4R and UTNV 6R. • B2P - Additional coil with 2 post-heating rows for UTNV 4R and UTNV 6R. • EFL - Side extraction of filters on opposite side from water connections. Accessory modules • Outlet plenum, with aluminium nozzles with double row of adjustable fins. • Outlet plenum, with galvanized steel nozzles with double row of fins. Accessories supplied loose • Inlet grille in galvanized steel. • Inlet grille in aluminium. • Side extraction of filters on opposite side from water connections. • Panel with room thermostat, summer/winter switch, ON/OFF valve signal. P. 103 Unit-System 14,5÷98,2 kW 22,3÷226,8 kW UTNV with outlet plenum. Front filter extraction and inlet grille. 030 050 080 100 125 150 ➋ Nominal heating capacity UTNV 2R kW 22,3 40,5 61,3 77,5 95,1 114,9 ❶ Nominal cooling capacity UTNV 4R kW 14,5 27,6 40,5 52,6 63,6 77,6 ➋ Nominal heating capacity UTNV 4R kW 37,6 68,3 101,6 130,1 159,2 190,8 ❶ Nominal cooling capacity UTNV 6R kW 19,2 33,9 51,8 65,5 81,4 98,2 ➋ Nominal heating capacity UTNV 6R kW 44,9 80,6 122,1 153,8 189,2 226,8 UTNV MODEL ➋ Nominal heating capacity of additional coil B2R-B2P kW Air flow speed max. m3/h Available head pressure max. UTNV 4R Pa ❸ Sound pressure level max. speed dB(A) ❶/➋ Absorbed power kW 22,3 40,5 61,3 77,5 95,1 114,9 3.150 5.600 8.500 10.600 13.100 15.600 170 170 170 173 170 172 60,0 62,9 62,7 69,2 66,0 64,6 0,75 1,50 2,20 3,00 4,00 4,00 230-1-50 400-3-50 230-1-50 400-3-50 230-1-50 400-3-50 400-3-50 400-3-50 400-3-50 030 050 080 100 125 150 mm 1.000 1.200 1.500 1.750 2.050 2.400 H - Height UTNV 2R/4R/6R/4R+2R/2R+4R mm 1.600 1.800 2.000 2.000 2.000 2.000 H - Height 6R+2R mm 1.800 2.000 2.200 2.200 2.200 2.200 P - Depth mm 680 760 840 840 840 840 Weight kg 165 270 360 465 520 570 Main supply V-ph-Hz DIMENSIONS AND WEIGHTS L - Width In the following conditions: ❶ Air: 27°C D.B.; 19°C W.B. - Water: 7/12°C. Maximum speed ❷ Air: 20°C - Water: 70/60°C. Maximum speed ❸ At 3 m from the point of air outlet. H L P TERMINAL UNITS Side filter extraction on request. UTNR 012÷041 Air renewal terminal units with heat recovery Accessory modules Construction features • KPAV - Plenum with side openings for vertical unit installation, designed to house the filter accessory and dampers. Unit for environment air renewal with heat recovery: for horizontal or vertical installation with dedicated accessory (KPAV). Structure: load-bearing frame with extruded 30-mm aluminium sections, glass-loaded nylon or painted aluminium nylon corners, and closed cell seals. Sandwich panels with a total thickness of 25 mm, in double galvanised sheet steel, hot-injected polyurethane insulation, density 45 kg/m3. Removal side panels for external bypass of the recovery unit. Module with recovery unit: aluminium air-air type package recovery unit with rough surface plates, housed in a built-in condensation collection tray in galvanised steel. Filters: folded, thickness 48 mm (thickness 98 mm on UTNR 032 and 041), as standard on external air, with efficiency rating of G3, extractable from below. Fan module: double inlet centrifugal electric fans directly connected at 3 speeds with protection rating IP44 (IP 20 on UTNR 041). Accessories supplied loose • Two-range additional water heating coils, with left-hand connections. • Electric heater in carbon steel with galvanised steel fins (available in versions with single-phase and three-phase power supply). • Air outlet synthetic filters. • Air outlet metal filters. • Galvanised steel damper on external air inlet and/or outlet. STANDARD CONTROLS For wall installation ➔ Panel with speed and summer/winter switch. ➔ Panel with room thermostat, summer/winter switch, ON/OFF valve signal and electric heater. Key: ❖ Factory fitted ➔ Supplied loose P. 105 Unit-System 5,4÷18,6 kW 012 017 023 032 50 52 52 50 50 kW 5,44 8,02 10,89 14,51 18,59 ➋ Nominal heating capacity of additional coil kW 10,30 15,68 21,08 28,78 37,59 ❸ Air flow MAX m3/h 1.200 1.700 2.300 3.200 4.100 MED m3/h 1.050 1.450 1.850 2.600 3.400 MIN m3/h 925 1.150 1.550 2.100 2.600 ❸ Supply available static pressure Pa 100 120 150 120 160 ❹ Sound pressure level Supply MAX dB(A) 57 56 58 60 60 MED dB(A) 54 53 56 58 58 ❶ Recovery efficiency % ❶ Nominal heating capacity 041 MIN dB(A) 52 52 53 52 55 MAX m3/h 1.200 1.550 2.300 2.880 4.000 MED m3/h 1.050 1.300 1.650 2.430 2.850 MIN m3/h 925 1.150 1.020 2.020 1.850 ❸ Available outlet head pressure Pa 100 90 130 100 90 ❹ Sound pressure level Return MAX dB(A) 53 55 58 62 58 MED dB(A) 52 54 54 59 55 MIN dB(A) 49 50 49 54 50 ❸ Return air flow Supply/return motor absorbed power W 300/184 300/300 420/350 550/550 600/600 Main supply V-ph-Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 DIMENSIONS AND WEIGHTS L - Width mm 012 017 023 032 041 1.000 1.140 1.200 1.260 1.480 H - Height mm 440 520 520 600 620 P - Depth mm 1.260 1.380 1.500 1.700 1.760 UTNR weight (with water coil) kg 90 90 90 150 230 Weight KPAV kg 20 24 28 30 35 ❸ Unit without accessories, with standard filter ❹ At 3 m from air outlet, with free nozzle and directionality factor of 2. In the following conditions: ❶ Outdoor air: 20°C D. B. - 50% R.H.; Renewal air –5°C D.B., 80% R.H. Maximum speed - ❷ Water 70°C with Δt 10°C. Maximum speed VERTICAL INSTALLATION WITH KPAV ACCESSORY HORIZONTAL INSTALLATION INTERNAL EXTERNAL INTERNAL P EXTERNAL H L TERMINAL UNITS UTNR MODEL CONTROLS ◆ ◆ ◆ ◆ ◆ ◆ Output 0 - 10 V DC 4-pipe systems ◆ 2-pipe systems ◆ Continuous ventilation or thermostat. Air sensor with remote control option ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ AUTOMATIC AUTOMATIC SPEED ◆ MINIMUM SPEED REGULATION ±5°C ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ AUTOMATIC ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ➔ Wall-mounted electronic panel ➔ ❖ MASTER electronic card ◆ ◆ ◆ ◆ ◆ ➔ Wall-mounted electronic panel ➔ ❖ MASTER electronic card ◆ ◆ ◆ ◆ ◆ ➔ Remote control ➔ ❖ MASTER electronic card ➔ ❖ Receiver on the machine ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ➔ ❖ SLAVE electronic card Additional modules: ➔ ❖ Probe for additional coil ➔ ❖ ON/OFF valves management module ➔ ❖ Electric heater module Key: ❖ Factory fitted ➔ Supplied loose ◆ ◆ ◆ Serial interface. ◆ Electric heater ◆ INSTALLATION: ➔ ❖ Electronic panel on machine ➔ ❖ MASTER electronic card on machine ON/OFF valves control ◆ ADVANCED CONTROLS RECEIVER ◆ Electric heater control ➔ KTCV2 wall mounted ➔ KBTCV2 - ❖ TCV2 on the machine ➔ KTCVA wall mounted ➔ KBTCVA - ❖ TCVA on the machine ➔ KTCVR wall mounted ➔ KBTCVR - ❖ TCVR on the machine ➔ KTCVM wall mounted ◆ 4-pipe systems KTCVR ➔ KTIE1 wall mounted ◆ 2-pipe systems KTIE1 ◆ Master/Slave KTCVA ◆ Comfort functions KTCV2 ◆ Regulation functions KCV2 ◆ ON/OFF valves control ➔ KCV2 wall mounted ◆ Summer/winter switch TATM C ➔ KTA - ❖ TATM on the machine Minimum thermostat INSTALLATION: ➔ KC - ❖ C on the machine Room thermostat STANDARD CONTROLS 3-speed ON/OFF switch for fan coil units and terminal units ◆ ◆ ◆ P. 107 ELECTRONIC CONTROL FOR TERMINAL UNITS REGULATION FUNCTIONS TOO COOL Summer on/off signal. FULL AUTO Automatic management. FULL AUTO MEMORY Memorisation of operating mode. COOL Cooling. ADVANCED FUNCTIONS DRY Dehumidification. ECONOMY (ECO) Energy savings. FAN - AUTOFAN Manual/automatic ventilation. LOCK FUNCTION HEAT (HEAT+ELECTRIC HEATER) Heating (Heating with electrical heater). REMOTE CONTROL LOCK FUNCTION Locked operation for hotel room. ON/OFF remote control Remote start-up and shutdown. COMFORT FUNCTIONS ORIENTING/SWING Fixed/swinging louver. SUMMER/WINTER remote control Summer/winter remote signal LOCK FUNCTION CLOCK Display of set time. ON SECURITY control External security (window contact). TIMER Programmed on/off. OFF PROBE IN/PROBE OUT Remote working probe. PROBE IN SLEEP Night-time air conditioning. CONTINUOUS VENTILATION Continuous ventilation or thermostat. CONT COMFORT CONTROL OCCUPANCY SLAVE 1 SLAVE 2 SLAVE 3 SLAVE 4 COMFORT CONTROL Regulator +/- 3°C OCCUPANCY Occupancy for hotel rooms ALARM Alarm signals. SLAVE 5 MASTER/SLAVE FUNCTION MASTER - SLAVE Master/slave function MASTER/SLAVE FUNCTION ✔ The MASTER/SLAVE function allows centralized management of up to 5 units (called SLAVE) via a single unit (called MASTER) equipped with a control panel or remote control. MASTER FAN COIL UNITS AND TERMINAL UNITS IDROWALL FREND BrioEV YardyEV UTNC-EV UTNB UTNA CONTROLS HOT START Winter on/off signal Integrated solutions for system management iDRHOSS is an advanced system for the management of hydronic air conditioning systems, developed to meet the comfort needs of any civil or residential location. iDRHOSS offers a series of functions, such as centralized management, automatic summerwinter changeover and operating times, whilst always working towards energy saving. Area controller Advanced controls for terminal units Flush panel Control panel for centralized management of all the units in the system. Recessed panel Cooling Remote control unit P. 109 iDRHOSS SYSTEM AREA CONTROLLER FUNCTIONS ✔ Start-up and shutdown of the entire system (chiller/heat pump and terminal units). ✔ Display and modification of central unit. ✔ Centralised management of a number of zones and modification of the terminal units (ON/OFF, set-point, operating mode, fan speed, sleep/economy mode). ✔ Management of daily time bands (ON/OFF) for the terminals, different for each zone, and for the chiller/heat pump with possible variations of set-point. ✔ Automatic seasonal switchover and real time status and system operating display in real time (ON/ON by timer OFF/OFF by timer OFF by alarm, SUMMER/WINTER/BOILER). ✔ Automatic boiler management (and of any bypass valve on the water system) in the event of shutdown of the heat pump. ✔ Start-up and shutdown by GSM. ✔ Display and setting of current date and time. ✔ Configuration of the serial network and of the terminals installed in the zones. CHILLER ASSEMBLIES TCAEY-THAEY 105÷265 TCCEY-THCEY 105÷111 TCAI-THAI 150 TCCE-THCE 114÷126 TCHEY-THHEY 105÷112 TXHEY 105÷112 TXAEY 117÷265 FAN COIL UNITS AND TERMINAL UNITS IDROWALL FREND BrioEV YardyEV UTNC-EV UTNB UTNA iDRHOSS ✔ Display for the main unit and for the terminal units of possible alarm conditions (identified by a code and corresponding description). RHOSS SUPERVISOR RHOSS supervision software RHOSS SUPERVISOR is the Rhoss supervision system that allows monitoring and remote management of Rhoss units used in a hydronic system. This makes it possible to monitor, via a computer, the operation of Rhoss chillers, heat pumps or terminal units, or the entire iDRHOSS integrated hydronics system. RHOSS SUPERVISOR is easy to use both in terms of system configuration and access to characteristic unit parameters because it uses the Microsoft Internet Explorer interface. RHOSS SUPERVISOR makes it possible to set up a local supervision system via serial connection of the microprocessor cards of the RHOSS units to a computer. If the local computer is connected to the information system network of the building (Ethernet with TCP/IP protocol), the information can be shared with any other computer on the network. Supervision can also be carried out remotely via GSM modem connection. In both cases, access to supervisor information can be protected by various levels of password. P. 111 RHOSS SUPERVISOR FOR CHILLERS AND HEAT PUMPS RHOSS SUPERVISOR allows: ✔ control of unit start-up and shutdown; ✔ display and modification of summer/winter operation of the heat pump units; ✔ display of temperature of water coming into and going out of the unit; ✔ display of values of the three power supply voltages (QPack range); ✔ display of alarms; ✔ scheduling of actions to be performed in the event of an alarm in a unit. In fact, it is possible to send a fax or e-mail with all information required for remote service of the cooling unit. ✔ scheduling/programming of periodic maintenance. RHOSS SUPERVISOR FOR FAN COIL UNITS AND TERMINAL UNITS: RHOSS SUPERVISOR allows: ✔ control of unit start-up and shutdown; ✔ display and modification of fan speed; ✔ display and modification of operating mode (Auto, Cool, Dry, Fan, Heat, Heater); ✔ display and modification of set-point values; ✔ display of alarms; ✔ scheduling of actions to be performed in the event of an alarm in a unit. In fact, it is possible to send a fax or e-mail with all information on the event); ✔ set daily time zones with start/stop function, modification of set-point and setting of operating mode. SUPERVISION SOFTWARE ✔ display and modification of set-point values; CTA ADV 240÷22920 Advance Range Air handling units in sections Construction features Main modules: mixing box, discharge and re-circulation section, recovery section, air treatment section, fan section, filtering and silencing section. Dampers: with opposing galvanized or aluminium fins. Filters: pleated, rotary, bags, absolute and with active carbons. Humidifiers: with spray nozzles, with humidifying package, steam, by atomization, with compressed air. Heat exchangers: finned package coils supplied in different materials depending on their use and the vector fluid used, all fully extractable on runners. Droplet eliminator: in polypropylene, in galvanized steel, in aluminium, in stainless steel. Fans: with forward blades, reversed blades with a wing profile, plug fan, with air flow regulator. The optimal choice in terms of aeraulic performance, efficiency and noise levels can always be found among the wide range of products available. Heat recovery: with twin coils, with cross flows, rotary, with heat pipes. All our heat recovery units are selected to obtain the maximum possible energy saving in keeping with current standards. Structure: load-bearing in aluminium profiles, glass-loaded nylon or painted aluminium nylon corners, continuous base or base with modular sections depending on installation requirements. PROFILES • Standard: available from 40mm with the possibility of installing an insulating panel measuring 25 or 42 mm or from 60mm with the possibility of installing a 46 or 63 mm panel. • Curved profiles: with internal perfectly rounded corners for use in sterile facilities. • Thermal block profiles: constructed with double profiles, with a rolled polyamide bar in between to eliminate thermal transfer. PANELS • Realized in double box-bent sheet metal with insulating material in the middle, available in: - hot-injected polyurethane with an average density of 45 kg/m3; - rock wool with oriented fibres with an average density of 95 kg/m3. • Internal and/or external materials available for panels: galvanized sheet steel, peraluman, pre-painted or prelaminated galvanized sheet metal, stainless steel. Versions • Standard: with single fan with a rectangular cross-section. • Narrow range: with a square cross-section single fan. • Lowered range: with paired fans. • For use in specialized sectors (food service, hospitals, pharmaceutical, etc.). Sizes: a total of 55 sizes subdivided between standard and slim series are available and are shown in the dimension table. The CTA ADV's are compliant with the essential safety requirements as set forth by EC Directives 89/392/EC and subsequent modifications concerning machine safety, 73/23/EC and subsequent modifications concerning electrical components that operate within given voltage ranges. The ADV units comply with the provisions of standards UNI EN 292, UNI EN 294, CEI EN 60204-1, UNI EN 563, UNI EN 1050, UNI 10893, UNI EN ISO 3744, ISO 3864, UNI EN 1886. 471 541 661 741 881 1071 1241 1700 1950 2400 2700 3200 3850 4500 mm 730 730 770 810 870 880 880 1030 mm 680 740 740 800 800 900 940 980 1461 1751 2021 2361 2831 3371 3941 4571 Air flow rate at 2.5 m/s m3/h Front dimension B Front dimension H Slim range MODEL Air flow rate at 2.5 m/s m3/h 5300 6300 7300 8500 10200 12200 14000 16500 Front dimension B mm 1030 1030 1050 1220 1410 1610 1610 1630 Front dimension H mm 1120 1280 1310 1340 1350 1350 1520 1700 5441 6561 7611 9131 10711 12751 15041 18361 Slim range MODEL Air flow rate at 2.5 m/s m3/h 19500 23500 27500 33000 38500 46000 55000 66000 Front dimension B mm 1740 2020 2150 2500 2780 2900 3350 3800 Front dimension H mm 1880 1880 2000 2000 2060 2300 2300 2420 Standard range MODEL 240 300 380 440 570 710 800 920 850 1080 1360 1700 2050 2450 2850 3300 950 970 1080 1080 1080 1080 660 720 720 750 820 880 1530 1720 2080 2300 2500 Air flow rate at 2.5 m/s m3/h Front dimension B mm 730 820 Front dimension H mm 630 630 1070 1220 1380 Standard range MODEL Air flow rate at 2.5 m/s m3/h 3850 440 4950 5500 6200 7500 8300 9000 Front dimension B mm 1230 1360 1360 1430 1480 1550 1630 1630 Front dimension H mm Standard range MODEL 880 880 920 920 990 1070 1070 1170 2920 3270 3600 4300 5250 6060 7500 8480 Air flow rate at 2.5 m/s m3/h 10500 12000 13000 15500 19000 21800 27000 30500 Front dimension B mm 1630 1650 1650 1930 2130 2310 2700 2850 Front dimension H mm 1300 1300 1400 1560 1560 1700 1700 1700 9750 11400 12600 13900 16580 19860 22920 Standard range MODEL Air flow rate at 2.5 m/s m3/h 35000 41000 45500 50000 59500 71500 82500 Front dimension B mm 3000 3000 3200 3600 3850 4040 4540 Front dimension H mm 1870 2050 2210 2210 2210 2420 2490 CURVED 40 42 25 42 STANDARD 40 40 60 60 63 46 63 H 60 60 WITH THERMAL BLOCK 60 63 46 63 B 60 AIR HANDLING UNITS 371 1300 Slim range MODEL CTA ADVR: RHOSS completes its offer with the ADV units equipped with their own electrical panel with dedicated thermal regulation system. The units are supplied with a detailed aeraulic diagram, a wiring diagram and a description of the regulation. The air handling units are wired in all the regulation and power components such as: electric motors, electronic humidifiers, inverters, servo-motors and sensors. All the water circuit components: are carefully selected, installed and precalibrated in the factory. The unit is functionally tested in all its components in the factory. Start-up of the units is performed by Rhoss qualified personnel to ensure reliability over time. Selection software: The innovative CTA ADV selection programme allows rapid and correct unit sizing. The programme guides the user in the choice of components, provides a technical sheet for professionals complete with a detailed description and drawing and an up-to-date economic report. The resulting configuration allows the order to be transmitted directly to the production department, thus considerably reducing the delivery times of the units. PACKAGED DE-HUMIDIFIERS FOR SWIMMING-POOLS P. 116 DRESY-DAESY 108÷2111 Dry-Pool ADV Range DE-HUMIDIFIERS FOR SWIMMING-POOLS with or without heat recovery for pool water, air-cooled and with centrifugal fans. Range with hermetic Scroll compressors and R410A refrigerant gas. Construction features Refrigerant circuit: optimised to keep the refrigerant charge to a minimum. Compressor: hermetic, rotary Scroll compressor, complete with thermal protection . Evaporating coil with copper pipes and pre-painted aluminium fins: ensures durability even in aggressive environments like the swimming-pool. Condensing coil: with copper pipes and aluminium fins. Anticorrosion treatments are available for applications in saline air environments (coastal areas) or environments with chemically aggressive air. Partial or total condensation heat recovery: thermally insulated, with brazed plates and made of materials suitable for the treatment of pool water. The water circuit is complete with water flow differential pressure switch. G3 grade air filter: it is installed inside the machine and protects the unit from dirt thus improving the quality of re-circulation air. Condensation drain pan: in stainless steel. Pressure gauge: refrigerant circuit high and low pressure gauges. Fans: Centrifugal fans with adjustable belt and pulley transmission. The treated air outlet is vertical: horizontal air outlet is also available. Available external head pressure is equal to 150 Pa (100 Pa with additional hot water coil). Power supply: main 400V three-phase 50 Hz. Structure: the frame is made of highly resistant extruded aluminium thermal block profiles with a 40x40 mm cross-section. The panels are in double sheet steel (galvanized steel on the inside and RAL 9002 pre-painted on the outside) which encloses a hot-injected polyurethane insulation with an average density of 45 Kg/m3. Concealed screws are used. Control: microprocessor electronic control. Models DRESY: de-humidifier equipped with 45% water side and +55% air side heat recovery. DTESY: de-humidifier equipped with 100% water side heat recovery. DAESY: de-humidifier with 100% air heat exchange. The water-side heat recovery are available both with plate heat exchanger in special stainless steel suitable for operation with chlorine water and with Cupro/Nichel shell and tube heat exchanger for operation with water treated with salt chlorination. Versions • For outdoor installation • Fan horizontal outlet Factory fitted accessories • • • • Room thermostat. Room humidistat. Auxiliary electric heaters installed to assist the condenser. Additional hot water coil with copper pipes and aluminium fins. Also available with pre-painted aluminium fins or with copper pipes and fins. • Condensing coil with pre-painted aluminium fins or with copper pipes and fins. • 200 Pa pressure fans available both for the standard version and the version with auxiliary water coil. • Versions with greater head pressure available on request. Accessories supplied loose • Anti-vibration joint for fan oulet ducts. ADDITIONAL MODULES: • DAHR - Heat recovery with cross flows heat exchanger which can be installed next to the base module. Heat recovery: with highly efficient cross flows and acrylic prepainted aluminium fins (suitable for unclean/aggressive air). Possibility of carrying out 100% free-cooling with the same module. • DAFC - Free-cooling which can be installed next to the base module. With fresh air, discharge and re-circulation 0-100% modulating dumpers. Construction features Fan: centrifugal fan with adjustable belt and pulley transmission. A safety micro-switch is provided on the door of the fan module. Structure: the frame is made of highly resistant extruded aluminium thermal block profiles with a 40x40mm cross-section. The panels are in double sheet steel (galvanized steel on the inside and RAL 9002 pre-painted on the outside) which encloses a hot-injected polyurethane insulation with an average density of 45 Kg/m3. Concealed screws are used. Dampers: motorised in alluminium. The inlet and outlet dampers can be provided either towards the top or the rear side. Control: the microprocessor electronic control fully manages the unit through energy saving logical management systems. P. 117 l/h kW l/h kW No. No. Pa m3/h kW kg/h KPa mm mm mm DRESY-DAESY MODEL ❶ Dehumidification capacity ❶ Total absorbed power ➋ Dehumidification capacity ➋ Total absorbed power Compressors/circuits Fans ❸ Fan available head pressure Fan nominal air flow Standard fan motor power Heat recovery water flow Pressure drops Width Height Depth l/h kW l/h kW No. No. Pa m3/h kW kg/h KPa mm mm mm 108 7,78 2,63 7,74 3,20 1/1 1 150 2.200 1 x 0,55 921,6 6,4 1.300 1.380 790 237 37,29 10,81 33,98 9,02 2/2 2 150 9.000 1 x 1,5 3.569,0 34,0 2.370 1.890 850 112 11,34 4,14 11,30 4,85 1/1 1 150 3.000 1 x 0,75 1.337,3 6,9 1.300 1.380 790 242 42,02 11,89 38,30 15,13 2/2 2 150 9.300 1 x 2,2 4.148,0 88,7 2.370 1.890 850 115 14,52 4,39 13,17 5,43 1/1 1 150 3.500 1 x 0,75 1.479,0 10,6 1.600 1.580 850 250 48,71 14,17 43,59 18,53 2/2 2 150 11.000 1x3 5.180,0 69,0 2.370 1.890 850 118 18,14 5,61 16,45 6,98 1/1 1 150 4.500 1 x 1,1 1.835,0 10,2 1.600 1.580 850 254 53,89 16,00 49,35 20,08 2/2 2 150 12.400 1 x 2,2 5.490,0 34,0 2.870 1.975 1.230 122 21,60 5,85 19,46 7,37 1/1 1 150 4.700 1 x 0,75 2.111,0 88,7 1.600 1.890 850 262 61,24 18,13 56,00 22,12 2/2 2 150 14.400 1x3 6.215,0 54,0 2.870 1.975 1.230 128 27,43 8,26 25,16 9,99 1/1 1 150 6.200 1 x 1,5 2.537,0 34,0 1.600 1.890 850 271 70,95 21,82 64,82 26,97 2/2 2 150 16.500 1x4 7.307,0 78,7 2.870 1.975 1.230 281 80,74 25,18 72,44 32,11 2/2 2 150 18.000 1 x 5,5 8.746,2 68,0 2.870 1.975 1.230 131 30,46 9,42 28,07 11,35 1/1 1 150 7.200 1 x 2,2 3.107,5 54,0 1.600 1.890 850 294 93,74 28,52 83,37 35,89 2/2 3 150 21.000 1 x 5,5 9.986,0 64,1 3.470 1.975 1.230 AVAILABLE VERSIONS DRESY air DRESY+BA Pool water air Pool water air boiler DRESY+BA+DAFC air DRESY+BA+DAHR Pool water boiler 2111 111,13 34,58 96,44 44,91 2/2 3 150 22.000 1 x 5,5 11.168,5 35,2 3.970 1.975 1.230 ➋ Exchanging heat only with air. Ambient air temperature: 27°C, 65% R.H. ❸ Without additional coil. In the following conditions: ❶ Exchanging heat with air and water. Ambient air temperature: 27°C, 65% R.H. Pool inlet/outlet water temperature 26/32°C. DAESY 136 36,19 10,51 33,04 13,10 1/1 1 150 8.200 1 x 1,5 3.731,0 78,7 2.100 1.890 850 air Pool water boiler DE-HUMIDIFIERS FOR SWIMMING-POOLS DRESY-DAESY MODEL ❶ Dehumidification capacity ❶ Total absorbed power ➋ Dehumidification capacity ➋ Total absorbed power Compressors/circuits Fans ❸ Fan available head pressure Fan nominal air flow Standard fan motor power Heat recovery water flow Pressure drops Width Height Depth English edition - 1 PRODUCT RANGE WATER CHILLERS HEAT PUMPS FAN COIL UNITS AIR HANDLING UNITS 08 RHOSS S.P.A. Via Oltre Ferrovia, 32 - 33033 Codroipo (UD) - Italy tel. +39 0432 911611 - fax +39 0432 911600 rhoss@rhoss.it - www.rhoss.it - www.rhoss.com IR GROUP S.A.S. 7 rue du Pont à Lunettes - 69390 Vourles - France tél. +33 (0)4 72318631 - fax +33 (0)4 72318632 irsaprhoss@irgroup.fr RHOSS Deutschland GmbH Hölzlestraße 23, D-72336 Balingen, OT Engstlatt - Germany tel. +49 (0)7433 260270 - fax +49 (0)7433 2602720 info@rhoss.de - www.rhoss.de RHOSS MERCOSUR Benjamin Constant 576 - 1er Piso C.P. 1214 - Asuncion Paraguay tel/fax +595 21 493 897 - www.rhossmercosur.com Italy branch offices: Area Nord-Est: 33033 Codroipo (UD) - Via Oltre Ferrovia, 32 tel. +39 0432 911611 - fax +39 0432 911600 Area Nord-Ovest: 20041 Agrate Brianza (MI) Centro Colleoni - Palazzo Taurus, 1 tel. +39 039 6898394 - fax +39 039 6898395 Area Centro-Sud: 00199 Roma - Viale Somalia, 148 tel. +39 06 8600699-707 - fax +39 06 8600747 Area Sud: 80143 Napoli - Via G. Porzio - Centro Direzionale - Isola G8 tel. +39 081 7879121 - fax +39 081 7879135 RHOSS S.P.A. declines all responsabilities for possible mistakes in the catalogue and reserves the right to alter the features of their products without notice in the interests of continuous improvement. K10021EN Ed.1 / 2008 02.08 - 6.000 - Printing: gfp.it