Solenoid valves for steam and high temperatures
3/2 way - Normally Closed - Direct Operated
Series
128
1
2
0
Coil energised - open
Coil de-energised - closed
0
0
2
General description:
Coils:
PARKER series 128 solenoid valves are
direct operated and do not require a minimum differential pressure to operate.
They are used for superheated water.
Series 128 valves are normally closed.
The inlet and outlet fittings are situated on
the mounting flange and enclosing tube.
For series 128 valves class “F” coils
(155°C) are available encapsulated in thermoplastic containing 30% glass fiber, (ZB,
YB types). Class “H” coils (180°C) are available encapsulated in thermoplastic containing 40% of glass fiber ( ZH type).
All the coils are for continuous service,
100% E.D.
The rated voltage tolerance is:
±10% for A.C. power supply and
+10% -5% for D.C.
The “Z” and “Y” coils can be used on a.c.
with a frequency of 50/60 Hz (dualfrequency).
The “Z” coils have Faston terminals for DIN
43650A connectors with protection to IP65.
The “Y” coil has terminals with 2 x 1,000
mm cables with protection to IP67.
Temperatures:
N.C.
Normally closed
1
Flange fittings
1
2
The working temperature for media is:
maximum
+140°C
minimum
-30°C (Ruby)
minimum
-10°C (FKM)
The maximum ambient temperature is:
• with class “F” coils
+50°C
• with class “H” coils
+80°C
Application:
Series 128 solenoid valves are ideal for
automatic control of superheated water for
dispensing espresso coffee.
Models are available with various seals and
fitting configurations for maximum
flexibility of application and installation.
Some typical application examples:
• Espresso coffee machines, for bars;
• Espresso coffee machines, for the home;
• Automatic dispensers.
Installation:
The valves can be mounted in any position
without jeopardising their operation. It is
however advisable to install them with the
coil in a vertical position above the body.
Approvals:
• For the coils:
115V/50-60Hz, 220-230V/50-60Hz,
240V/50-60Hz
ZH 09 24V/50-60Hz
ZH 12 12VDC, 24VDC
YB 09 220-230V/50-60Hz
ZB 09
• For the coils:
ZB 09 220-230V/50-60Hz,240V/50-60Hz
YB 09 220-230V/50-60Hz
• UL Recognized Comp. coils mark:
24V/60Hz, 110-120V/60Hz,
208-240V/60Hz
YB 09 24V/60Hz, 110-120V/60Hz,
208-240V/60Hz
ZB 09
Series
76
128
Parker Hannifin S.p.A.
via E. Fermi, 5
20060 Gessate (Milano) - Italy
SPECIFICATION
• Valve body:
• Seals:
• Enclosing tube:
• Plunger:
• Spring:
• Shading ring:
• Fitted sit:
CW617N UNI EN 12165:98 brass stamping
Ruby - Viton
AISI 304 stainless steel
AISI 430F stainless steel
AISI 302 stainless steel
Copper
AISI 304 stainless steel
Fittings
ØG
Valve
type
Nominal
orifice Ø
Flow
coefficient Kv
Minimum
pressure
[”]
[ ]
[mm]
[m3/h]
[bar]
-
128 I
128 G
128 I-UL
128 G-UL
1,3 - (2,5)*
1,3 - (2,5)*
1,3 - (2,5)*
1,3 - (2,5)*
0,070
0,070
0,070
0,070
0
0
0
0
Note:
Coil type
[ ]
ELECTRICAL
FEATURES
MATERIALS
for: superheated water
Power
[ W]
A.C.( ~ ) D.C.( = )
ZB 09
YB 09
ZH 09
ZH 14
in A.C.( ~ )
[bar]
10
10
10
10
A.C.( ~ )
D.C.( = )
9
9
9
14
12
12
12
16
ZB 12
YB 12
ZH 12
ZH 16
Max differential
pressure (M.O.P.D.)
Coil
type
in D.C.( = )
[bar]
10
10
10
10
[
Insulat.
class
F
F
H
H
Weight
Notes
]
[Kg]
[
Z-Y
Z-Y
Z - UL
Z - UL
0,310
0,310
0,310
0,310
1-2
1-2
1-2
1-2
]
1) NP (nominal pressure): 25 bar.
2) Maximum static pressure 14.5 bar (for Viton sealing, maximum static pressure: 12 bar). (*) Diameter of the discharge.
drg. 2
TYPE
A
B
C
D
[”]
[mm]
[mm]
[mm]
[mm]
128 I
32
66
32
45,5
128 G*
32
63,5
32
43
B
B
D
D
DIMENSIONS
drg. 1
*drg. 2
A
PM
ORDER CODE
VALVE
BODY
C
A
C
128
[V]
DISCHARGE
FITTINGS
I
Coil
type
ZB
ZH
ZB
ZH
YB
YB
ZH
ZH
conical
G cylindrical
24 V
50/60 Hz
09
09
12
12
09
12
14
16
[Hz]/d.c.
115V 220-230 V 240 V
50/60 Hz 50/60 Hz 50/60 Hz
•
•
•
•
•
•
•
•
12 V
d.c.
24 V
d.c.
•
•
•
•
•
•
•
•
•
•
•
SEAL
SERIES
Note:
R
Ruby
V
Viton
Coil type
24 V / 60 Hz
ZB 09 UL
YB 09 UL
•
•
110-120 V / 60 Hz 208-240 V / 60 Hz
•
•
•
•
Valves supplied with coils in a multipack. Connectors to be ordered separately.
77
Parker Hannifin S.p.A.
via E. Fermi, 5
20060 Gessate (Milano) - Italy
Download PDF