Derby 9 DMX
I N S T R U C T I O N
M A N U A L
Manual version 1.0
This user manual will help you operate this product safely and quickly,
so please spend a few minutes to read through the enclosed information.
Due to continuous product development, please check for the
latest version of this product manual at:
www.novopro.co.uk
Designed and engineered in the UK and manufactured in China for Novopro Ltd.
Novopro Ltd is a trade-only supplier and only supply wholesale to trade resellers.
At the end of the products working life, please take it to a recycling plant for environmentally friendly disposal.
Due to continuous product development, specifications and appearance are subject to change. E&OE.
© Copyright Novopro.
Thank you for purchasing this Novopro product.
To optimise it’s performance, please read these instructions carefully to familiarise yourself with the basic operations of the unit.
Please retain them for future reference. This unit has been tested at the factory before being shipped to you. To prevent or
reduce the risk of electrical shock or fire, do not expose the unit to rain or moisture. To prevent a fire hazard, do not expose the
unit to any naked flame sources. Unplug this apparatus during lightning storms or if it is unlikely to be used for long periods of
time. When installing the unit, please ensure you leave enough space around the unit for ventilation. Slots and openings in the
unit are provided for ventilation to ensure reliable operation of the product and to protect it from overheating. To prevent fire
hazard, the openings should never be blocked or covered.
The unit is powered by the mains, always handle the power cable by the plug. Never pull out the plug by pulling on the cable.
Never touch the power cable when your hands are wet as this could cause an electric shock. Do not tie a knot in the cable. The
power cable should be placed such that it is not likely to be stepped on. A damaged power cable can cause a fire or give you an
electrical shock. Check the power cable periodically, if you ever find that it is damaged, replace it before using the unit again. The
voltage of the available power supply differs according to country or region. Be sure that the power supply voltage of the area
where this unit is to be used meets the requirements of the unit.
The lightning flash symbol inside a triangle is to alert the user to the presence of high voltage within the unit’s enclosure
that may be of sufficient power to constitute a risk of electrical shock to persons. Caution: to prevent the risk of electric
shock, do not attempt to open the unit. No user-serviceable parts inside. Refer all servicing to qualified service
personnel. The exclamation mark inside a triangle is intended to alert the user to the presence of important operating
and maintenance instructions in the literature accompanying the appliance.
Select the installation location of your unit carefully. Avoid placing it in direct sunlight or locations subject to vibration and
excessive dust. Do not use the unit where there are extremes in temperature (do not exceed 40ºC).
Manufacturer EC Declaration of Conformity
In compliance with the following requirements:
RoHS Directive (2011/65/EU) and WEEE Directive (2012/19/EU) and (2002/96/EU).
At the end of the products working life, please ensure that the unit is taken to a recycling plant for environmentally friendly
disposal - IT MUST NOT be disposed of with general household waste.
l
l
l
l
l
l
l
Overhead rigging
Important - the installation must be carried out by qualified service personal only. Improper installation can result in serious
injuries and /or damage to property. Overhead rigging requires extensive experience. Working load limits should be respected,
certified installation materials should be used and the installed unit should be inspected regularly for safety.
Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging and servicing.
Locate the unit in a well ventilated spot, far away from any flammable materials and/or liquids. The fixture must be fixed
at least 50cm from surrounding walls
The device should be installed out of reach of people and outside of areas where persons may walk by or be seated.
A safety cable must be used when rigging the product overhead.
Before rigging, please ensure that the installation area can hold minimum point load of 10 times the device`s weight.
The device should be well fixed; a free swinging mounting is dangerous.
Do not cover any ventilation opening as this may result in overheating
DMX512 connection
If you are using a standard DMX controller, you can connect the DMX output of the controller directly to the DMX input of the
first unit in a DMX chain. If you wish to connect a DMX controller with other XLR outputs you will need to use adapter cables.
DMX output
DMX output
1 = Shield | 2 = Signal (-) | 3 = Signal (+)
Connect the DMX output of the first unit in a DMX chain with the DMX input of the next unit in the chain. Always connect the
output of one unit with the input of the next unit until all units are connected.
Unpacking and safety Please unpack your new product carefully. Your new product should reach you in perfect condition.
Please check that no damage has occurred during transit. If any damage is found, do not operate your unit, please contact the
retailer you purchased it from immediately.
Packing list: lighting unit / mounting bracket / IEC mains lead / instruction manual / remote control / carry bag.
Rear panel functions
1.
2.
3.
4.
5.
6.
7.
8.
9.
Key to rear panel diagram
DMX Input - 3 pin male XLR interface for DMX connections
DMX Output - 3 pin female XLR interface for DMX connections
Mains power input IEC socket / AC 220-240V 50/60Hz
LED function setting display - shows the various menus and the selected functions
MENU button - used to select the different menu items
UP button - used to move ‘up’ through the function menus
DOWN button - used to move ‘down’ through the function menus
ENTER button - used to confirm your menu selection
Microphone - for sound-to-light for operation
Remote control functions
ON/OFF - switches the unit On or Off
DMX ON/OFF - switches the DMX On or Off
STOP START - switches the motor On or Off
MUSIC 1 - sound show mode 1
MUSIC 2 - sound show mode 2
MUSIC 3 - sound show mode 3
FLASH - switches the strobe On or Off
A1 - red + blue + warm white colour group
A2 - orange + white + yellow colour group
A3 - green + purple + UV colour group
A4 - 9 colour jump change
A5 - 3 colour jump change
A6 - gradual change 1
A7 - gradual change 2
SPEED +/- - increases or decreases speed
Troubleshooting the remote control
The remote control comes supplied with a CR2025 battery. To ensure that the battery isn’t discharged during transport, the
factory inserts a small piece of transparent plastic between the battery and the contacts. This small plastic sheet must be
removed before the remote control will operate. When changing the battery, note the polarity of the battery being removed, the
new battery must be facing the same way up as the old battery. With the remote face down (buttons facing the floor) the plus
("+") side of the battery should be facing upwards (i.e. towards the ceiling). If the remote control doesn’t appear to work, first
check that the unit is set to respond to the remote by following the instructions at the top of this section. If the remote still
doesn’t work, replace the battery with a new CR2025 battery. Always ensure that there is an uninterrupted line of site between
the remote and the unit’s IR remote control sensor.
Main Menu
To select any of the menu options, press the MENU button on the rear of the unit to select the mode required. Once you have
made a selection then press ENTER to confirm. Use the UP and DOWN buttons to choose the desired menu option.
Mode
A1
A2
A3
A4
A5
A6
A7
S1
S2
SA
S3
FL
SLAU
A001
Function
Motor speed
Auto
1~9
Sound
0~20
01-10
01-20
1-9
001~512
Control effects
Red + blue + warm white – ON / motor speed from slow to fast
Amber + cool white + yellow – ON / motor speed from slow to fast
Green + purple + UV – ON / motor speed from slow to fast
9 colour jump change / motor speed from slow to fast
3 colour jump change / motor speed from slow to fast
Gradual change 1 / motor speed from slow to fast / with no strobe effects
Gradual change 2 / motor speed from slow to fast / including strobe effects
Sound mode / colour change / including strobe effects / light on / black out
Sound mode / colour change / motor speed from fast to slow
Sound mode
Sound mode
Strobe mode
Slave mode
DMX Control
7 Channel DMX control
Channel
Function
1
Master dimmer
2
3
4
Red + blue +
warm white
Amber + yellow
+ cool white
Green + purple
+ UV
5
Strobe
6
Motor
7
Choose
program
DMX
0-7
8-255
0-7
8-255
0-7
8-255
0-7
8-255
0-10
11-255
0-5
6-127
128-255
0-9
10-39
40-69
70-99
100-129
130-159
160-189
190-219
220-249
250-255
Function
Blackout
0-100% linear dimmer
Blackout
0-100% linear dimmer
Blackout
0-100% linear dimmer
Blackout
0-100% linear dimmer
No strobe
Strobe (6 different speeds)
Motor stop
Static position
Ocillation (9 different speeds)
Manual – channels 1-6 available
A1 - red + blue + warm white – ON / motor speed from slow to fast
A2 - amber + cool white + yellow – ON / motor speed from slow to fast
A3 - green + purple + UV – ON / motor speed from slow to fast
A4 - 9 colour jump change / motor speed from slow to fast
A5 - 3 colour jump change / motor speed from slow to fast
Gradual change 1 / motor speed from slow to fast / with no strobe effects
Gradual change 2 / motor speed from slow to fast / including strobe effects
S1 - sound mode 1
S2 - sound mode 2
DMX address setting
When controlling the unit (or units) with a DMX controller, each one must be set with a specific DMX address. You can choose to
set all units with the same DMX address or you can set every unit with its own DMX address. If all units are set with the same DMX
address all units will be synchronised and operate in the same way, you cannot control each unit separately. If you set each unit
with a different DMX address, they will receive the DMX signal from their own DMX address. You will now be able to control each
unit individually. The DMX address that you set for each unit must be determined by the number of channels. This unit has 7
channels, therefore you should set the starting address of the first unit to 1, the second unit must then be set to 8 (7+1), the third
unit must be set to 15 (8+7) and so on.
Technical Specifications
DMX512 control channels: 7 Channels
DMX512 Input & Output connection: 3 pin XLR
Mode: DMX512 / Auto / Sound-to-Light / Master/Slave / Remote control
LEDs: 9 x 3w (red / green / blue / warm white / yellow / amber / purple / UV / cool white
Power supply: IEC mains / AC 220-240V 50/60Hz
Power consumption: 30W
Dimensions (WxDxH): 200 x 162 x 140mm (not including bracket)
Weight: 1.1Kgs
Due to continuous product development, specifications and appearance are subject to change.