Performance data sheet
PURE@TAP
Order no. 8115012
The PURE@TAP water filter has been tested and certified under NSF / ANSI Standard 42 &
53 and CSA B 483 by CSA International (MC # 235425).
NSF / ANSI 42 – Aesthetic effects
Influent challenge
concentration
Substance
Chlorine, taste and odor
2.0 mg/L ± 10%
reduction
Minimum reduction
requirement
Percent reduction
≥ 50%
> 99%
NSF / ANSI 53 – Health effects
Influent challenge
concentration
min. 50.000 L
Substance
Cyst reduction
Minimum reduction
requirement
99.95%
Percent reduction
> 99.99%
Technical data
Water pressure min.
Water pressure max.
Water temperature min.
Water temperature max.
pH area
Flow rate
Total capacity of
activated carbon cartridge
Total capacity of
micro filtration cartridge
Cartridge replacement:
103 kPa (15 psi)
345 kPa (50 psi)
1 °C (34 °F)
30 °C (86 °F)
5.5 - 9.5
2 L/min (0.53 gpm)
2000 L (528 gal)
order no. 8115016
2000 L (528 gal)
order no. 8115017
at least every 6 months
(depends on water quality and consumption)
Please observe the installation and operation instructions.
This point of use filter is a chemical and mechanical reduction system, that conforms to NSF / ANSI 42 for the
reduction of chlorine, taste and odor and to NSF / ANSI 53 for the reduction of cysts as verified and substantiated by
test data. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection
before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain
filterable cysts.
Do not clean any plastic parts with detergents containing alcohol or solvents.
JUDO Water Treatment Inc.
Toronto, Ontario, Canada
Tel: 866 - 451 - 5836 (toll-free)
Fax: 877 - 761 - 3335 (toll-free)
e-mail: info@judo.online.com
judo-online.com
1702259 • 2010/09