Installation
S19-220B
Wall-Mounted Eyewash
Table of Contents
Pre-Installation Information . . . . . . . . . . . . . .
Installation Instructions. . . . . . . . . . . . . . . . . .
Assembly of Components . . . . . . . . . . . . . . .
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . .
215-158B Rev. J; ECN 08-503
© 2008 Bradley Corporation
Page 1 of 4
2/13/08
2
3
4
4
P.O. Box 309, Menomonee Falls, WI USA 53052-0309
PHONE 1-800-BRADLEY FAX (262) 251-5817
bradleycorp.com
S19-220B
Installation
WARNING
Read this installation manual completely to ensure proper installation, then file it
with the owner or maintenance department. Compliance and conformity to drain
requirements and other local codes and ordinances is the responsibility of the installer.
Installation
Packing List
IS
TH
SIDE
UP
•
•
•
•
Separate parts from packaging and make sure all parts are accounted for before
discarding any packaging material. If any parts are missing, do not begin installation
until you obtain the missing parts.
Flush the water supply lines before beginning installation and after installation is
complete. Test the unit for leaks and adequate water flow. Main water supply to the
eyewash should be “ON” at all times. Provisions shall be made to prevent unauthorized
shutoff.
Da
Da te
Da tum
te
Sig ned
Sig ned
ned
P.O
TES
. Box
DIE
ESS SEST THI
309
Tes AI
S
, Me
Rep t-op HEBGER UNI
Ven ort
nom
DO ÄT T EAC
1ST
dur til(e anyera
te MA
one
H
Tes ch )
val DAI WÖ WE
e
sig
Un wö ma ve( RE CHE EK
Fal
un ne t le
ters che lfun s)
ls,
NTL
rap en fon
WI
chr ntli ctio eac
ICH
por basctio
530
ns h
ift. ch
t imm. nne
ZU
immwe
Jeg im
51
S'il
ek
me
PRÜ
Tes
edi and
édi y à nt lich
tbe
FEN
Sig
ate
ate que des e Stö
trie
Un ned
.
ly. sig
me lqu val
n
Sig ter
nt. e ves run b prü
bel
g
cho
ne sch
ow
sof fen
rift
.
se cha
ort , bes
qui que
Da
me
ne sem ldetäti
Da te
va ain n. gt
Da te
pas e
te
Sig
fait et
R
The ANSI Z358.1 standard requires an uninterruptible supply of flushing fluid at a
minimum 30 PSI (0.21 MPa) flowing pressure. Flushing fluid should be tepid per ANSI
Z358.1.
P.O. BOX 309, MENOMONEE FALLS, WI 53052-0309 USA
TEL: 1-800-BRADLEY FAX: (262-251-5817)
http://www.bradleycorp.com
114-051
The inspection and testing results of this equipment should be recorded weekly to verify
proper operation. This equipment should be inspected annually to ensure compliance
with ANSI Z358.1.
Workers who may come in contact with potentially hazardous materials should be
trained regarding the placement and proper operation of emergency equipment per ANSI
Z358.1.
For questions regarding the operation or installation of this product, visit www.
bradleycorp.com or call 1-800-BRADLEY.
Product warranties may also be found under ”Product Information” on our web site at
www.bradleycorp.com.
2
2/13/08
Bradley Corporation • 215-158B Rev. J; ECN 08-503
Installation
S19-220B
Installation
Supplies Required:
•
•
•
•
•
(3) 3/8” wall fasteners and bolts
Pipe sealant
Piping to 1/2” IPS water supply inlet on unit
Piping to 1-1/4” IPS drain outlet for eyewash
Sign-mounting hardware
NOTE: Local codes may require the installation
of a backflow prevention valve to complete proper
installation. Compliance with local codes is the
responsibility of the installer. Valve must be tested
annually to verify that it is functioning properly.
Backflow prevention valves are not included with
the fixture and may be supplied by the contractor
or purchased from Bradley Corporation.
13-5/8"
(346mm)
Ø 10-3/4" (254mm)
Step 1: Install inlet drain fitting
15-7/8" (403mm)
4"
(102mm)
NOTE: The top of the eyewash heads should be
33”–45” (838mm–1143mm) from the floor.
1. Position the inlet drain fitting over the
1-1/4” drain outlet pipe from wall.
2. Using the inlet drain fitting as a template,
mark the bolt hole locations on wall OR
install three suitable fasteners (supplied
by installer) for 3/8” bolts in the wall at the
marked hole locations.
3. Bolt the inlet drain fitting to the wall or wall
fasteners using 3/8” bolts (supplied by
installer).
7-3/8"
(187mm)
2-1/4"
(57mm)
7-1/2"
(191mm)
Ø 5/16"
(8mm)
5-1/4"
(133mm)
Step 2: Assemble components
1. Assemble the remaining eyewash
components as shown on page 4.
• Apply pipe sealant (supplied by installer) to
all male-threaded pipe joints.
• Use a strap wrench around pipes when
tightening to prevent pipe marring.
Step 3: Connect water supply
1. Connect the water supply piping to the 1/2”
IPS inlet on the eyewash (piping supplied by
installer).
2. Connect the tailpiece to the 1-1/4” IPS drain
outlet on the eyewash.
3. Mount the safety sign to the wall using signmounting hardware (supplied by installer).
36" (914mm)
Suggested
Height
To Floor
30-1/2"
(775mm)
Suggested
Height
To Floor
4-5/8"
(119mm)
8-1/4"
(210mm)
Wall
4. Open the water supply lines. Test for leaks
and adequate water flow.
NOTE: All dimensions assume standard thread
engagement. Variations in manufacturing allow for
+/- 1/8 (3mm) per threaded joint. To find the tolerance
of a dimension, add the number of thread joints in
between a dimension and multiply it by 1/8 (3mm).
Bradley Corporation • 215-158B Rev. J; ECN 08-503
2/13/08
3
S19-220B
Installation
Assembly of Components and Parts List
1.8
8
1.7
1.6
1
P.O. BOX 309, MENOMONEE FALLS, WI 53052-0309 USA
TEL: 1-800-BRADLEY FAX: (262-251-5817)
http://www.bradleycorp.com
1.5
114-051
Flow Control
This End
9
1.4
R
P.O. Box 309, Menomonee Falls, WI 53051
TEST THIS UNIT EACH WEEK
DIESES GERÄT 1ST WÖCHENTLICH ZU PRÜFEN.
ESSAI HEBDOMADAIRE
Test-operate valve(s) each week and sign below.
Report any malfunctions immediately.
Ventil(e) wöchentlich im Testbetrieb prüfen, bestätigt
durch Unterschrift. Jegliche Störung sofort melden.
Test le fonctionnement des valves chaque semaine et
signe en bas. S'il y à quelque chose qui ne va pas fait
un rapport immédiatement.
Date
Datum
Date
Signed
Unterschrift
Signe
Date
Date
Date
Signed
Signed
Signed
1.3
1/2" IPS
Supply Inlet
1.2
1.1
4
6
2
7
3
5
1-1/4" IPS
Drain Outlet
4.1
NOTE: Items 1.1-1.8 come preassembled as Item 1.
Item
Part No.
Qty
Description
Item
Part No.
Qty
Description
1
S90-295
1
Stainless Steel Bowl Assembly
2
113-006LQ
1
1/2” NPT Pipe x 3-1/2”
1.1
111-061
1
Inlet Drain Fitting
3
169-025
1
Elbow
1.2
124-028
1
Gasket
4
S27-282
1
1/2” Ball Valve with Nut
1.3
187-053
1
Stainless Steel Receptor
4.1
110-215
1
Nut only
1.4
173-009
1
Cup Strainer
5
128-135
1
Handle, Plastic
1.5
S21-071
1
Supply Stem
6
142-002DA
1
Washer
1.6
113-1159
1
Spacer, Drain
7
269-167
1
Tailpiece
1.7
S05-091
1
Eyewash Yoke Assembly
8
114-051
1
Safety Sign
1.8
107-371
2
Dust Cover
9
204-421
1
Inspection Tag
Prepack S45-122 includes Items 4, 4.1, 5, 6
Prepack S45-123 includes Items 4.1, 5, 6
Prepack S45-1782 includes Items 1.2, 1.4, 1.5, 1.6
4
2/13/08
Bradley Corporation • 215-158B Rev. J; ECN 08-503
Download PDF