IES1024 Series Industrial Ethernet switch User

Support MAC address learning, aging automatic
Summarize
Support single or redundancy power supply (100
IES1024 series is an industrial grade and unmanaged industrial
240VAC/DC)
Ethernet switch. The industrial Ethernet switch consists of 24 Fast
Ethernet ports. Support Fast Ethernet copper ports and optical
Reliable Industrial grade design
Industrial grade 4 design, -40-75 work temperature
economical solution for your industrial Ethernet connection. The
No fan deign
switch with a single power series and redundancy power series of
IP30 protection grade
two products can be optional. Dual power supply product support
19 inch rack mounting
fiber port option. The industrial Ethernet switches provide an
do not support the redundancy function.
The switches have an operating temperature range of -40 to 75°C,
Panel layout
redundancy backup function. The single power supply products
Front view
and are designed with low consumption and without fan. The
that your Ethernet equipment can withstand the rigors of
Rear view
industrial applications.
Industrial Ethernet switch
rugged hardware design makes the switch perfect for ensuring
Packing list
IES1024 Series
The industrial Ethernet switch is shipped with the following items.
User manual
If any of these items are missing or damaged, please contact your
customer service representative for assistance.
Industrial Ethernet switch
User manual
1
Warranty card
Power cable
1
1
Rackmount ears
2
Feature
1
High performance network exchange technology
Support IEEE802.3, IEEE802.3u, IEEE 802.3x
Support 8K MAC address
Support 12.8Gbps switching fabric capacity
10/100BaseT(X)(RJ45)
Store and Forward switching process type
Shenzhen 3onedata Technology Co., Ltd.
Plug-and-play, auto MDI/MDI-X connection
1. Restore factory settings
Tel: +86-755-26702668
Support auto negotiation speed, F/H duplex mode, and auto
2. Console port
send data control
3. Link/ACT LED
Fax: +86-755-26703485
www.3onedata.com
-1-
Power supply input
RJ 45 port support automatic MDI/MDI-X operation. Can connect
4. Systems running LED
5. The power LED
The Industrial Ethernet switches have singe power and
the PC, Server, Converter and HUB .Pin 1,2,3,6 Corresponding
6. Relay alarm LED
redundancy power two kinds of power input. The singe power
connections in MDI. 1→3, 2→6, 3→1, 6→2 are used as cross
7. Rackmount ears
series
wiring
8. Power input and Relay output terminal block
100~240VAC/DC power entered (L/+, GND, N/-) and relay
10Base-T/100Base-TX are used in MDI/MDI-X, the define of Pin
9. 10/100BaseT(X) (RJ45) ports
output (R+, R-).The unmanaged Ethernet switch relay alarm
in the table as below.
10. 100Base-FX ports
function is invalid. Terminal diagram is as follows:
rear
panel
provides
5
bit
wiring
terminal
for
in
the
11. Rear panel connector LED
8
Dimension
port
of
Converter
and
HUB.
NO.
MDI signal
MDI-X signal
1
TX+
RX+
2
TX-
RX-
3
RX+
TX+
6
RX-
TX-
4, 5, 7, 8
—
—
The redundancy power series rear panel provides two terminal
Note
blocks (5 bits) for P1 and P2 input. The redundant power can be
used independently. P1 and P2 can supply power at the same time,
once either of these two powers fails, another power can acts as
“TX±”Transmit Data± “RX±”Receive Data±
“—”Not Use.
MDI (straight-through cable)
backup automatically to ensure reliability of the network. Voltage
input range is 100
240VAC/DC (terminal block defined as P1:
L/+, GND, N/-; P2: L/+, GND, N/- ).
Important notice:
1. Power ON operation: first of all, insert power cable’s terminal
block into device’s power port, then insert power supply plug into
MDI-X (Cross over cable)
power source
2. Power OFF operation: First off all, unpin power plug, then
strike the terminal block, please take care of operation sequence.
Communication connector
Ethernet interface is different. Unit (mm)
The series of products are the same size, and the number of the
1
MDI-X
10/100BaseT(X) Ethernet port
The pinout of RJ45 port display as below, connect by UTP or STP.
The connect distance is no more than 100m. 100Mbps is used
MDI/MDI-X auto connection makes switch easy to use for
120Ω of UTP 5; 10Mbps is used 120Ω of UTP 3, 4, 5.
customers without considering the type of network cable.
100Base-FX Fiber port
100Base-FX full-duplex SM or MM port, SC/ST/FC type .The
fiber port must be used in pair, TX (transmit) port connect remote
switch’s RX (receive) port; RX (receive) port connect remote
-2-
Installation
4. All the cable cannot have break-down and terminal in the
switch’s TX (transmit) port.
The optical fiber connection supports the line to instruct enhance
Before installation, confirm that the work environment meet the
the reliability of network effectively.
installation require, including the power needs and abundant
5. Cables should be straight in the hallways and turning;
Suppose: If you make your own cable, we suggest labeling the
space. Whether it is close to the connection equipment and other
6. Cable should be straight in the groove, and cannot beyond the
two sides of the same line with the same letter (A-to-A and
equipments are prepared or not.
groove in case of holding back the inlet and outlet holes.
B-to-B, shown as below, or A1-to-A2 and B1-to-B2).
1. Avoid in the sunshine, keep away from the heat fountainhead or
Cables should be banded and fixed when they are out of the
middle;
the area where in intense EMI.
groove;
2. Examine the cables and plugs that installation requirements.
7. User cable should be separated from the power lines. Cables,
3. Examine whether the cables be seemly or not (less than 100m)
power lines and grounding lines cannot be overlapped and
according to reasonable scheme.
mixed when they are in the same groove road. When cable is
4. Power: 100-240VAC/DC power input
75
Storage Temperature: -40 85
middle of alignment rack;
working temperature: -40
5. Environment
too long, it cannot hold down other cable, but structure in the
8. Pigtail cannot be tied and swerved as less as possible.
Relative humidity 5% 95%
LED Indicator
Rack mount installation
terrible loss of link). Its banding should be moderate, not too
In most of industrial application, it is convenience to use rack
tight, and should be separated from other cables;
each LED is described in the table as below.
System Indication LED
LED
State
ON
PWR1
OFF
ON
PWR2
OFF
RUN
Description
Power is being supplied to
power input PWR1 input
Power is not being supplied
to power input PWR1 input
Power is being supplied to
power input PWR2 input
Power is not being supplied
to power input PWR2 input
cable for maintaining.
(The package provided parts of components)
2. Check installation place strong or not, have the place to install
Specification
Technology
the device or not.
3. Put the device into rack, aim at the screw hole of device and
Standard: Support IEEE802.3, IEEE802.3u, IEEE 802.3x
rack, fixed it in strong screw. Easy and convenience to
Flow control: IEEE802.3x flow control, back press flow control
operation.
Exchange attribute
Wiring Requirements
100M forward speed: 148810pps
Cable laying need to meet the following requirements,
100M maximum filter speed: 148810pps
1. It is needed to check whether the type, quantity and
Transmit mode: store and forward
specification of cable match the requirement before cable
Switching fabric capacity: 12.8Gbps
laying;
MAC address table: 8K
System is not running well
Blinking
System is running well
ON
Port connection is active
Blinking
Data transmitted
laying position need to match construction requirements, and
Port connection is not active
cable length depends on actual position;
OFF
9. It should have corresponding simple signal at both sides of the
1. Check if have rack mount installation tools and components
ON/OFF
Link/ACT
(1~24)
mount installation, the step of installation is as follows:
LED indictor light on the front panel of product, the function of
Swerving radius cannot be too small (small swerving causes
2. It is needed to check the cable is damaged or not, factory
records and quality assurance booklet before cable laying;
3. The required cable specification, quantity, direction and
-3-
Memory: 4Mbit
Interface
Electric port: 10Base-T/100Base-TX auto speed control, Half/full
duplex and MDI/MDI-X auto detect
100M optic fiber port: 100Base-FX, SC/ST/FC connector
Console port: Retain
Unload consumption: 16.2W
Alarm port: Retain
Full load consumption: 18.3W
Transfer distance
IES1024-24F-P (100~240VAC):
Single-mode: 1310nm, 20/40/60Km
1550nm, 80/100/120Km
Unload consumption: 21.4W
Full load consumption: 22.6W
Working environment
Working temperature: -40
Power supply
75
85
Input voltage: 100 240VAC
Storage temperature:-40
Multi-mode: 1310nm, 2/5Km
standard CAT5/CAT5e cable
Twisted cable: 100M
Type of input: 3 bit terminal block
Relative Humidity: 5%~95% (no condensation)
Support single power series and dual supply series of two
Shell: IP30 protect grade, metal shell
products can be optional.
Installation: 19” 1U rack
Consumption
Size W×H×D : 441.6mm×45mm×208.9mm
IES1024-P (100~240VAC):
Unload consumption: 5.1W
Full load consumption: 9.7W
IES1024-2F- P (100~240VAC):
Unload consumption: 5.5W
Full load consumption: 10.7W
IES1024-4F - P (100~240VAC):
Unload consumption: 6.3W
Full load consumption: 11.2W
IES1024-8F-P (100~240VAC):
Unload consumption: 10.9W
Full load consumption: 14.8W
Mechanical Structure
Overload Current Protection: 1.2A
Industry Standard
EMI: FCC Part 15, CISPR (EN55022) class A
EMS: EN61000-4-2 (ESD), Level 4
EN61000-4-3 (RS), Level 3
EN61000-4-4 (EFT), Level 4
EN61000-4-5 (Surge), Level 4
EN61000-4-6 (CS), Level 3
EN61000-4-8, Level 5
Shock: IEC 60068-2-27
Free fall: IEC 60068-2-32
Vibration: IEC 60068-2-6
Certification
IES1024-12F-P (100~240VAC):
Unload consumption: 13.0W
Full load consumption: 16.6W
CE, FCC, RoHS, UL508 (Pending)
Warranty: 5 years
IES1024-16F-P (100~240VAC):
Unload consumption: 13.4W
Full load consumption: 18.6W
IES1024-20F-P (100~240VDC):
-4-
Download PDF