1.25 Gb/s RoHS Compliant Long-Wavelength
Pluggable SFP Transceiver
APS31123CDL2
Product Features

Up to 1.25Gb/s dual data links

Hot-pluggable SFP footprint

1310nm FP laser transmitter

Duplex LC connector

Up to 2km on 50/125µm MMF

Metal enclosure for lower EMI

Single +3.3V power supply

Low power dissipation <600mW

Commercial operating temperature range: 0°C
to +70°C
Applications

1.25Gb/s 1000Base-SX Ethernet

1.06 Gb/s Fibre Channel
General
ATOP’s APS31123CDL2 Small Form Factor Pluggable (SFP) transceivers are compatible with the Small Form Factor
Pluggable Multi-Sourcing Agreement (MSA). They simultaneously comply with Gigabit Ethernet as specified in IEEE
STD 802.3 and 1x Fibre Channel as defined in FC-PI-2 Rev. 10.0 .They are RoHS compliant and lead-free.
ATOP www.atoptechnology.com
Page 1
I.
Pin Descriptions
Pin
Symbol
Name/Description
Transmitter Ground
Ref.
1
VeeT
(Common with Receiver Ground)
1
2
TX Fault
3
TX Disable
4
MOD_DEF(2)
5
6
7
Rate Select
8
LOS
Loss of Signal indication. Logic 0 indicates normal operation.
4
9
VeeR
Receiver Ground (Common with Transmitter Ground)
1
10
VeeR
Receiver Ground (Common with Transmitter Ground)
1
11
VeeR
Receiver Ground (Common with Transmitter Ground)
1
12
RD-
13
RD+
14
VeeR
Receiver Ground (Common with Transmitter Ground)
15
VccR
Receiver Power Supply
16
VccT
Transmitter Power Supply
17
VeeT
Transmitter Ground (Common with Receiver Ground)
18
TD+
Transmitter Non-Inverted DATA in. AC Coupled.
19
TD-
20
VeeT
Transmitter Fault.
Transmitter Disable. Laser output disabled on high or open.
2
Module Definition 2. Data line for Serial ID.
3
MOD_DEF(1)
Module Definition 1. Clock line for Serial ID.
3
MOD_DEF(0)
Module Definition 0. Grounded within the module.
3
No connection required
Receiver Inverted DATA out.
AC Coupled
Receiver Non-inverted DATA out.
AC Coupled
1
1
Transmitter Inverted DATA in. AC Coupled.
Transmitter Ground (Common with Receiver Ground)
1
Notes:
1.
2.
3.
4.
Circuit ground is internally isolated from chassis ground.
Laser output disabled on TX Disable >2.0V or open, enabled on TX Disable<0.8V.
Should be pulled up with 4.7k - 10kohms on host board to a voltage between 2.0V and 3.6V.
MOD_DEF(0) pulls line low to indicate module is plugged in.
LOS is LVTTL output. Should be pulled up with 4.7k – 10kohms on host board to a voltage between 2.0V and
3.6V. Logic 0 indicates normal operation; logic 1 indicates loss of signal.
Pinout of Connector Block on Host Board
ATOP www.atoptechnology.com
Page 2
II.
Absolute Maximum Ratings
Parameter
Symbol
Min
Vcc
Maximum Supply Voltage
Storage Temperature
Case Operating Temperature
Max
Unit
-0.5
+4.0
V
TS
-40
+100
°C
TOP
0
+70
°C
RH
0
85
%
Relative Humidity
III.
Typ
Ref.
1
Electrical Characteristics (TOP=25°C, Vcc=3.3Volts)
Parameter
Symbol
Min
Supply Voltage
Vcc
3.00
Typ
Max
Unit
3.60
V
300
mA
Ref.
Supply Current
Icc
160
Input differential impedance
Rin
100
Single ended data input swing
Vin, pp
250
1200
mV
Transmit Disable Voltage
VD
Vcc – 1.3
Vcc
V
Transmit Enable Voltage
VEN
Vee
Vee+ 0.8
V
10
us
800
mV
3
300
ps
4
Transmitter
Transmit Disable Assert Time
Ω
2
Receiver
Single ended data output swing
Vout, pp
Data output rise time
tr
300
400
Data output fall time
tf
300
ps
4
LOS Fault
VLOS fault
Vcc – 0.5
VccHOST
V
5
LOS Normal
VLOS norm
Vee
Vee+0.5
V
5
Deterministic Jitter Contribution
RXΔDJ
80
ps
6
Total Jitter Contribution
RXΔTJ
122.4
ps
Notes:
1.
2.
3.
4.
5.
6.
Non condensing.
AC coupled.
Into 100 ohm differential termination.
20 – 80 %
LOS is LVTTL. Logic 0 indicates normal operation; logic 1 indicates no signal detected.
Measured with DJ-free data input signal. In actual application, output DJ will be the sum of input DJ and ΔDJ.
ATOP www.atoptechnology.com
Page 3
IV.
Optical Characteristics (TOP=25°C, Vcc=3.3 Volts)
Parameter
Symbol
Min
Typ
Max
Unit
Ref.
1
Transmitter
Output Opt. Power
PO
-15
-
-8
dBm
Optical Wavelength
λ
1275
1310
1350
nm
Spectral Width
σ
-
-
3
nm
tr/tf
-
170
260
ps
2
Deterministic Jitter Contribution
TXΔDJ
-
-
0.07
UI
3
Total Jitter Contribution
TXΔTJ
-
-
0.007
UI
Optical Extinction Ratio
ER
9
-
-
dB
Optical Rise/Fall Time
Receiver
Average Rx Sensitivity
RSENS
-
-
-24
dBm
Maximum Received Power
RXMAX
0
-
-
dBm
Optical Center Wavelength
λC
1270
-
1600
nm
LOS De-Assert
LOSD
-
-
-25
dBm
LOS Assert
LOSA
-36
-
-
dBm
0.5
-
-
dB
LOS Hysteresis
4
Notes:
1.
2.
3.
Class 1 Laser Safety, Tested with 50/125µm MM fiber.
Unfiltered, 20-80%.
Measured with DJ-free data input signal .In actual application, output DJ will be the sum of input DJ and ΔDJ.
4.
Measured with PRBS 2 -1 at 10
V.
General Specifications
7
-12
BER .
Parameter
Symbol
Min
Typ
Max
Units
Ref.
Data Rate
BR
-
-
1250
Mb/sec
1
Bit Error Rate
Max. Supported Link Length on
50/125μm MMF @ Gigabit Ethernet
BER
-
-
LMAX
-
-
-12
2
10
2
km
3,4
Notes:
1.
Gigabit Ethernet and 1x Fibre Channel compliant.
2.
3.
4.
Tested with a PRBS 2 -1 data pattern.
Dispersion limited per FC-PI-2 Rev. 10.
Attenuation of 0.55 dB/km is used for the link length calculations. Please refer to the Optical Specifications in
Table IV to calculate a more accurate link budget based on specific conditions in your application.
7
ATOP www.atoptechnology.com
Page 4
VI.
Environmental Specifications
ATOP 1310nm Commercial Temperature SFP transceivers have an operating temperature range from 0°C to +70°C
case temperature.
Parameter
Symbol
Min
Typ
Max
Units
Case Operating Temperature
Top
0
+70
°C
Storage Temperature
Tsto
-40
+100
°C
VII.
Ref.
Mechanical Specifications
ATOP’s Small Form Factor Pluggable (SFP) transceivers are compatible with the dimensions defined by the SFP
Multi-Sourcing Agreement (MSA).
.
APS31123CDL2
ATOP www.atoptechnology.com
Page 5
IX.
PCB Layout and Bezel Recommendations
ATOP www.atoptechnology.com
Page 6
X.
For More Information
ATOP Technology co., ltd
5A of NO.C building of Tongfang information Habour, langshan Rd, High Tech Park,
Nanshan District, Shenzhen, China.
Tel: +86-755-86674946
Fax: +86-755-86296723
Email: sales@atoptechnology.com
Web: www.atoptechnology.com
ATOP www.atoptechnology.com
Page 7
Download PDF