INNOVATION SOLUTIONS SUPPORT RELIABILITY • SIP Style Footprint • 5V, 12V, 24V, & 48V Inputs • Single and Dual Outputs • Adjustable Output Voltages • Input - Output Isolation Key Market Segments & Applications Telecom & Datacom Test and Measurement Point of Load PV Series Single Inline Package DC-DC Converters (1-3 Watts) PV Features and Benefits Features • • • • Benefits Single Inline Package (SIP) Wide Input Voltage Range Isolated Output Wide Operating Temperature Range • • • • Uses Less PCB Area Accepts Unregulated Input Voltages Can Be Configured for + or - Outputs Supports Harsh Operating Environments Specifications Output Volt. ITEMS DC Input ranges Efficiency (typical) Output Voltage Accuracy Output Voltage Adjustment Preload Ripple & Noise Max Line Regulation Max Load Regulation Overcurrent Protection Overvoltage Protection Temperature Coefficient Cooling Isolation Voltage Isolation Resistance Shock Vibration Humidity (non condensing) Storage Humidity Operating Temp. Range Storage Temperature Weight (Typ) Size (LxWxH) Warranty VDC VDC A mV mV mV A % VAC Ohm °C g mm - 3.3V 5V 12V 5V: 4.5V-9V; 12V: 9V-18V, 24V: 18V-36V, 48V: 36V-72 77% ±5% 3.3V-3.67V 5V-6V 12V-15V 0 120mV 100mV 20mV 40mV Auto recovery (1) None 0.02%/°C Convection cooled Input-Output: 500VAC 1 min. (5mA) Greater than 100M 20G 10-55Hz (sweep for 1 min.) 1.5mm constant amplitude max 9G X,Y,Z 2 hours each 30%-90% RH (non condensing) 10%-95% RH (non condensing) -20 to 70°C, derate linearly to 50% load from 50 to 70°C -30°C to +85°C 5 28.5x18x8.5(PV1R5); 33x18x8.5 (PV3) 2 years Note: See Installation Manual for full details, test methods of parameters and application notes 1) Avoid operation in short circuit or overload for more than 30 seconds PV SERIES 1 Model Selector Model Single Output PV1R5-5-3.3 PV1R5-48-3.3 PV3-5-3.3 PV3-48-3.3 PV1R5-5-5 PV1R5-12-5 PV1R5-24-5 PV1R5-48-5 PV3-5-5 PV3-12-5 PV3-24-5 PV3-48-5 PV1R5-5-12 PV3-5-12 Dual Outputs PVD1R5-5-1212 PVD1R5-12-1212 PVD1R5-24-1212 PVD1R5-48-1212 PVD3-5-1212 PVD3-12-1212 PVD3-24-1212 PVD3-48-1212 Output Voltage (V) Output Current (A) Output Power (V) Input Voltage (V) 3.3 3.3 3.3 3.3 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 12.0 12.0 0.4 0.4 0.6 0.6 0.3 0.3 0.3 0.3 0.6 0.6 0.6 0.6 0.125 0.25 1.3 1.3 2.0 2.0 1.5 1.5 1.5 1.5 3.0 3.0 3.0 3.0 1.5 3.0 5.0 48.0 5.0 48.0 5.0 12.0 24.0 48.0 5.0 12.0 24.0 48.0 5.0 5.0 ±12.0 ±12.0 ±12.0 ±12.0 ±12.0 ±12.0 ±12.0 ±12.0 0.06 0.06 0.06 0.06 0.125 0.125 0.125 0.125 1.44 1.44 1.44 1.44 3.0 3.0 3.0 3.0 5.0 12.0 24.0 48.0 5.0 12.0 24.0 48.0 Pinout Pin Description Function -Vin +Vin +Vout -Vout NC COM TRM Negative Input Terminal Positive Input Terminal Positive Output Terminal Negative Output Terminal No connection Common Trim 2 PV SERIES Outline Drawing PV SERIES 3 LAMBDA EMEA AUSTRIA LAMBDA ELECTRONICS GmbH Aredstraße 22 A-2544 Leobersdorf Telephone: Facsimile: +43 (0) 2256 655 84 +43 (0) 2256 645 12 www.lambda-austria.com FRANCE LAMBDA SAS ZAC des Delaches, BP1077 - Gometz le Chatel 91940 Les Ulis Telephone: Facsimile: Web: +33 (0) 1 60 12 71 65 +33 (0) 1 60 12 71 66 www.lambda-f.com GERMANY LAMBDA GmbH Karl-Bold-Straße 40 D-77855 Achern Telephone: Facsimile: Web: +49 (0) 78 41 666 0 +49 (0) 78 41 5000 www.lambda-germany.com ISRAEL NEMIC LAMBDA LTD Kibbutz Givat Hashlosha 48800 Telephone: Facsimile: Web: +972 (0) 3 902 4333 +972 (0) 3 902 4777 www.nemic.co.il ITALY LAMBDA s.r.l. Via dei Lavoratori 128/130, 20092, Cinisello Balsamo (Mi) Telephone: Facsimile: Web: +39 (0) 02 61 29 38 63 +39 (0) 02 61 29 09 00 www.lambda-italy.com SWEDEN LAMBDA SCANDINAVIA PO Box 546, Rallarvägen 41 SE-184 25. Akersberga Telephone: Facsimile: Web: +46 (0) 8 598 94 090 +46 (0) 8 540 66 096 www.lambda-scandinavia.com UK LAMBDA UK Kingsley Avenue Ilfracombe Devon EX34 8ES Telephone: Facsimile: Web: +44 (0) 1271 856666 +44 (0) 1271 864894 www.lambda-gb.com LAMBDA NORTH AMERICA visit www.lambdapower.com for a list of Lambda offices and distributors LAMBDA ASIA visit www.densei-lambda.com for a list of Lambda offices and distributors LOCAL DISTRIBUTION 4 PV Datasheet Aug06 Iss1 PV SERIES