SECTION 3-TECHNICAL SPECIFICATION OF AUXILIARY UNITS
Technical informations about power, connection, switching and filter equipments for AE-Lift are listed in
Table 3.1.
Table 3.1 Technical Information about Part List for AE-LIFT
Contactor Selection
AEL05
AEL07
AEL11
AEL15
AEL22
Motor Contactors (K1-K2)
18 A
22-25 A
32 A
40 A
50 A
Line Input Contactors (MC)
18 A
18 A
25 A
32 A
50 A
Aux. Power Input Contactors (KUPS)
(Rescue Circuit)
9A
9A
12 A
18 A
25 A
AEL05
AEL07
AEL11
AEL15
AEL22
20 A
25 A
32 A
40 A
63 A
25 A
32 A
Circuit Breaker Selection
Power Input Supply Circuit Breaker
(F3X)
Input Power Circuit Breaker (F4)
(Control Circuit)
Battery Circuit Breaker (FBAT)
1A
16 A
16 A
6 A (1000 VA UPS için)
8 A (1200 VA UPS için)
10 A (1500 VA UPS için)
16 A (2000 VA UPS için)
20 A (3000 VA UPS için)
25 A (4000 VA UPS için)
32 A (5000 VA UPS için)
UPS Circuit Breaker (FUPS)
Minimum Cable Diameters
25 A
AEL05
2
AEL07
AEL11
AEL15
2
2
2
Power Input and Motor Cables
2.5 mm
4 mm
4 mm
6 mm
Braking Resistor Cables
2.5 mm2
2.5 mm2
2.5 mm2
2.5 mm2
Control Terminal Cables
0.75 mm2
Encoder Terminal Cables
0.35 mm2
F/7.5.5.02.95 R:1
10 mm2
2.5 mm2
0.75 mm2 (For 1000-1200 VA UPS)
1.5 mm2 (For 1500-2000 VA UPS)
2.5 mm2 (For 3000-4000 VA UPS)
4 mm2 (For 5000 VA UPS)
UPS Cables
Battery Cables
AEL22
4 mm2 (For 7Ah Battery) / 6 mm2 (For 12Ah Battery)
4
AE-LIFT
Rescue Function
AEL05
AEL07
AEL11
AEL15
AEL22
UPS-PowerCircuit
1500 VA
2000 VA
3000 VA
4000 VA
5000 VA
UPS-Control Circuit
1000 VA
5 x 7Ah
60V DC
Battery-Power Circuit
5 x 12Ah
60V DC
* Selection of battery, UPS and cable is made according to the parameter of Rescue Direction [C18] is
set to EASY DIRECTION.
** Minimum level of battery voltage must be 60V DC when battery is using for rescue operation
supplier and [C18] Rescue Direction is “Command Direction”.
Braking Resistor
Resistor Value
Minimum Power
(1)
AEL05
AEL07
AEL11
AEL15
AEL22
72 Ω
60 Ω
40 Ω
30 Ω
20 Ω
1200 W
1500 W
2200 W
3000 W
4400 W
(1)
Minimum preferred power of resistor listed in table. Use higher powered resistor than listed for long
period travel applications.
Line Filter (EMC)
AEL05
AEL07
AEL11
AEL15
AEL22
Current Capacity
20 A
20 A
30 A
40 A
60 A
F/7.5.5.02.95 R:1
5
AE-LIFT
Download PDF
Similar pages