Top of the range portable EC meter

manufactured by
Multiparameter EC/TDS/NaCl/resistivity | HI-98192
+
3.5 mm
connection
cal
check
interchangeable
electrode
replaceable
electrode
battery
powered
mains
powered
Top of the range portable
EC meter
This top of the range portable multiparameter
instrument offers all the advantages of a rugged
portable meter with the performance and features of
a bench top.
A professional waterproof meter, the HI-98192 complies
with IP67 standards and is supplied complete with all the
accessories needed to perform EC/TDS/NaCl/Resisitivity
measurements both in the lab and out in the field.
Easy to use with clear on-screen guidance
Three stages of conformity
Performs all 3 stages of USP <645>
water quality testing requirements.
On-screen guide
Users are provided with on-screen
instructions for each USP stage
Progress bar
Displays progress towards meeting
stage 2 stability requirements.
Authorised distributor
manufactured by
Multiparameter EC/TDS/NaCl/resistivity | HI-98192
A great set of benefits
4-ring conductivity probe
The 4-ring conductivity probe with its built in temperature
sensor is designed to take accurate readings over the complete
range with no need to switch electrodes. The polarisation
effect is also eliminated with the 4-ring technology.
Seven memorised standards with 5-point
EC calibration
Users can choose from seven memorized standards and obtain
up to a 5 point conductivity calibration. For salinity (% range),
HI-7037 standard allows users to make a one point calibration.
EC and TDS measurements are fully customizable and include:
Quick easy use connector
The unique quick-connect waterproof DIN connector is a
great bonus for field work. Replacing the need for a threaded
connection for a strong connection, it offers a secure method
of attachment that is equally quick and easy to remove.
Expanded range
An expanded conductivity range offers options from
0.000 μS/cm to 1000 mS/cm actual conductivity
(400 mS/cm temperature compensated). Ranges are also
included for TDS, resistivity and three salinity scales.
Methods
The meter performs all three stages of USP method required
for conductivity measurement in ultrapure water. A report is
generated when any of the three stages are met.
•
Cell constant selection between 0.0 and 10.000
•
Selection of linear or non-linear (natural water), or
•
No temperature compensation
The temperature compensation coefficient range is
configurable from 0.00 to 10.00%/°C with a choice of
reference temperatures of 15°C, 20°C and 25°C. Conductivity
to TDS factor is adjustable from 0.40 and 1.00.
Customised measurement profiles and
data logging
Up to 10 measurement profiles can be created with various
user settings including temperature compensation, range
selection, cell constant, and TDS conversion factors.
The log-on-demand mode allows the user to record and save
up to 400 readings while the lot logging at selected intervals
can store up to 1000 readings.
GLP data
Data can be transferred to a PC using the Hanna micro USB
cable and software.
GLP data includes date, time, standards used, temperature
compensation used, reference temperature, and TDS
conversion factor.
User support
For direct access to TDS data, simply press the dedicated GLP
key.
User guidance is provided on screen. Simply press the HELP
button and view content specific information based on the
screen being viewed at the time.
This instrument can be easily operated with
one hand and is housed in an IP67 rated
waterproof, rugged enclosure. The meter
and accessories all fit in our rugged, custom
thermoformed carrying case.
Authorised distributor
manufactured by
Multiparameter EC/TDS/NaCl/resistivity | HI-98192
Key features
Compact, rugged, waterproof to IP67
Methods
USP <645> capable for checking the
quality of water used in pharmaceutical
manufacturing
Salinity readings
Seawater salinity can be displayed as
% NaCl, natural seawater scale (ppt) or
practical salinity scale (PSU)
Calibration
Perform up to a 5 point calibration for
enhanced accuracy
Log on Demand: store measurement
data at the press of a button
Calibration timeout to alert the user at a
defined interval when the calibration has
expired
Interval lot logging: log measurements at
a selectable interval
Temperature compensation
Auto-ranging and fixed range
options
No temperature compensation, linear
temperature compensation and non
linear temperature compensation – ISO/
DIN 7888
Configurable linear temperature
compensation coefficient range from
0.00 to 10.00%/°C
GLP Features
GLP data provides calibration data
including date, time, standards used,
temperature compensation used,
reference temperature, and TDS
conversion factor (TDS)
Connectivity
PC connectivity via opto-isolated USB
with optional HI-92000 software
Code: HI-92000 (Software)
Code: HI-920013 (USB cable)
Authorised distributor
Data logging
User-friendly
Extensive battery life: approximately
100 hours of continuous use (without
backlight)
Menu driven for ease of use with virtualkey extended functionality
Contextual help at the press of a button
Easy read backlit, graphic, LCD
Multiple language selection
Auto Hold freezes first stable
reading on the display
manufactured by
Multiparameter EC/TDS/NaCl/resistivity | HI-98192
Ordering Information
Multiparameter waterproof meter | HI-98192
supplied with
• HI-763133 conductivity probe
Ideal for
• HI-7031M 1413 μS/cm calibration solution (230 mL)
environmental
• HI-7035M 111.8 mS/cm calibration solution (230 mL)
pharmaceutical
plating
water treatment
• 1.5V AA batteries (4)
food manufacturing
• instruction manual
water and wastewater
• 100 mL plastic beaker (2)
• HI-92000 PC software
• HI-920015 micro USB cable
• quick start guide
• quality certificate
• HI-720192 rugged carrying case
Specifications
Product Code
EC
TDS
Resistivity
Salinity
Temperature
HI-98192
Range
0.000 to 9.999 μS/cm*; 10.00 to 99.99 μS/cm; 100.0 to 999.9 μS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm (actual conductivity; temperature compensated to
400 mS/cm)
Resolution
0.001 μS/cm; 0.01 μS/cm; 0.1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm
Accuracy
±1% of reading (±0.01 μS/cm or 1 digit, whichever is greater)
Calibration
automatic up to 5 points with seven memorized standards (0.00 μS/cm, 84.0 μS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm)
Range
0.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt (g/L); 10.00 to 99.99 ppt (g/L); 100.0 to 400.0 ppt (g/L)
Resolution
0.01 ppm; 0.1 ppm; 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L)
Accuracy
±1% of reading (±0.05 mg/L (ppm) or 1 digit, whichever is greater)
Range
1.0 to 99.9 Ω•cm; 100 to 999 Ω•cm; 1.00 to 9.99 KΩ•cm; 10.0 to 99.9 KΩ•cm; 100 to 999 KΩ•cm; 1.00 to 9.99 MΩ•cm; 10.0 to 100.0 MΩ•cm
Resolution
0.1 Ω•cm; 1 Ω•cm; 0.01 KΩ•cm; 0.1 KΩ•cm; 1 KΩ•cm; 0.01 MΩ•cm; 0.1 MΩ•cm*
Accuracy
±1% of reading (±10 Ω or 1 digit, whichever is greater)
Range
% NaCl : 0.0 to 400.0%; practical salinity: 0.00 to 42.00 (PSU); natural seawater scale - UNESCO 1966: 0.00 to 80.00 (ppt)
Resolution
0.1%; 0.01
Accuracy
±1% of reading
Calibration
max. one point only in % range (with HI7037 standard); use conductivity calibration for all other ranges
Range
-20.0 to 120.0°C (-4.0 to 248.0°F)
Resolution
0.1°C (0.1°F)
Accuracy
±0.2°C; ±0.4°F (excluding probe error)
Calibration
one or two points
Temperature Compensation
noTC, Linear (-20 to 120 °C; -4 to 248°F), Non Linear - ISO/DIN 7888 (-0 to 36 °C; 32 to 96.8°F)
Measurement Modes
autorange, autoend, lock and fixed range
Reference Temperature
15°C, 20°C and 25°C
Temperature Coefficient
0.00 to 10.00 %/°C
TDS Factor
0.40 to 1.00
Electrode/Probe
HI-763133 platinum, 4-ring conductivity/TDS probe with internal temperature sensor and 4 m (13.2’) cable (included)
Log-on-demand
400 samples; lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples)
Memorized Profiles
up to 10
PC Connectivity
opto-isolated USB with optional HI 92000 software and micro USB cable
Battery Type/Life
1.5V AA batteries (4) / approximately 100 hours of continuous use (without backlight), 25 hours with backlight
Auto-off
user selectable: 5, 10, 30, 60 min or can be disabled
Environment
0 to 50°C (32 to 122°F); RH 100% (IP67)
Dimensions
185 x 93 x 35.2 mm
Weight
400 g
NB: *The 0.001 μS/cm EC range and 0.1 MΩ•cm not available with supplied probe