product catalog - Daikin Comfort

10.17
PRODUCT
CATALOG
Setting Daikin's new standards in
indoor comfort and efficiency
Table of Contents
4
AHU (Air Handling Kit) Integration Kit 110
Why choose Daikin?
5
Control Box EKE_CBAV3-US
112
What is Daikin VRV?
6
Why choose Daikin VRV?
7
Setting the Standards
Daikin VRV
Setting the Standards, Again
8
10
12
12
What does a VRV installation mean to you?
24
Vertical Market Applications
26
Product Portfolio 29
Outdoor Units
30
Indoor Units
32
VAM-GVJU - Energy Recovery Ventilator
120
DVS Dedicated Outside Air System
122
Controls 123
VRV Controls Solution
124
VRV Controls Systems Overview
126
Individual Controllers
128
BRC1E73 - Navigation Remote Controller
128
BRC4C82/BRC7E818/BRC7E83/BRC7E830 - Wireless Remote Controller
132
BRC2A71 - Simplified Remote Controller
Advanced Multi-Zone Controllers
132
134
Indoor units 41
Indoor Units Overview
44
FXMQ-PBVJU - DC-Ducted Concealed Ceiling Unit
(Medium Static) and DZK
46
FXDQ-MVJU - Slim-Duct, Built-In Concealed Ceiling Unit
50
DCS302CT1 - Central Remote Control
138
FXTQ-TAVJU Multi-Position Air Handling Unit
52
DCS301C71 - Unified ON/OFF Controller
139
54
DST301BA61 - Schedule Timer
139
FXMQ-MVJU - Concealed Ceiling Unit (Medium Static)
DCM601A71 - intelligent Touch Manager (iTM)
DCS601C71 - intelligent Touch Controller (iTC)
Centralized Controllers
136
138
140
OUTDOOR UNITS
External Equipment Control
134
INDOOR UNITS
Accessories34
115
118
PRODUCT PORTFOLIO
Which VRV System Offers the Best Solution?
Ventilation FXMQ-MFVJU - 100% Outside Air Processing Unit
OVERVIEW
Overview 56
FXFQ-TVJU - Round Flow Sensing Cassette 58
DCM009A51 - iTM BACnet ® Client Option
FXUQ-PVJU - 4-Way Ceiling-Suspended Cassette 62
750-831 - Daikin WAGO BACnet ®/IP Controller
FXZQ-MVJU9 - 2'x2' 4-Way Ceiling-Mounted Cassette
64
FXEQ-PVJU - Ceiling-Mounted Cassette
66
DCM014A51 - iTM BACnet ® Server Gateway Option
FXHQ-MVJU - Ceiling-Suspended Unit 68
DMS502B71 - Interface for use BACnet ®144
FXAQ-PVJU - Wall-Mounted Unit
70
DMS504C71 - Interface for LonWorks®144
FXLQ-MVJU9 - Floor-Standing Unit
72
DTA116A51 - DIII-Net/Modbus® Adapter144
Outdoor units 75
Daikin VRV AURORA™ Heat Recovery 208-230V & 460V
78
VRV IV - Air-Cooled Heat Recovery
82
VRV IV - Air-Cooled Heat Pump
Interface Solutions
VRV Monitoring Services
D-NET Air Conditioning Network Service System
140
141
142
142
145
145
Controls Product List
146
86
Support and Tools
149
90
Support and tools overview
151
VRV T-Series Water Cooled Systems
92
Selection software
152
VRV IV S - Series - Heat Pump 208-230V
98
VRV III PC - Air-Cooled Heat Recovery
152
Design and verification
153
Online and tablet reference material
153
VRV IV, VRV III PC, VRV T-Series Water Cooled Systems, & VRV IV-S 104
- Piping Length
Smartphone and mobile reference
154
VRV Accessories
106
Branch Selector Boxes
106
REFNET Pipe Joints
108
Hail Guard Kit for VRV IV
109
After sales and service
155
CONTROLS
Energy screening and simulation tools
VRV IV, VRV III PC, VRV T-Series Water Cooled Systems, & VRV IV-S 100
- Installation Space
VENTILATION
FXNQ-MVJU9 - Concealed Floor-Standing Unit
SUPPORT & TOOLS
3
4
www.daikincomfort.com
Why choose Daikin?
A history of industry-leading
product innovation
The total solution
Becoming a global leader in any industry takes more than
just time. For over 90 years Daikin has shown that it takes
industry-leading product innovation and a commitment to
excellence in order to climb to the top. This commitment led
Daikin to develop the first Variable Refrigerant Volume (VRV)
system in 1982 and to become a pioneer with our Variable
Refrigerant Volume systems.
Daikin’s products and controls are designed to provide a flexible,
scalable, total indoor comfort solution. We are committed to
supporting our customers at every phase of the project to
ensure that the highest quality and most cost effective solution
is the one that is provided. From project conception throughout
the life of an HVAC system, Daikin provides world class
products and support. A single source and total solution for your
HVAC requirements.
Daikin’s 3 core technologies
Daikin is an industry-leading HVAC technology company.
We develop state-of-the-art technology that provides indoor
comfort solutions for our customers. We do this by focusing
on 3 core technologies. Our refrigerant control technology
provides an efficient and effective way to transport heat. Daikin
inverter technology allows us to maximize energy efficiency and
heat pump technology provides an effective method for
moving refrigerant.
Research & development
Refrigerant control
Efficient heat transport
Manufacturing
DAIKIN
CORE
TECHNOLOGY
Inverter
Contributes to greater
energy savings and comfort
Heat pump
Absorbs or removes
heat from the air
Sales
After sales service
VRV Product Catalog
5
OVERVIEW
What is Daikin VRV?
One flexible package
Daikin VRV is a modular, commercially applied
air-conditioning and heating system that
distributes refrigerant from the outdoor unit
to multiple indoor units, providing efficiency,
comfortable individual user control and reliability
in one flexible package.
VRV is built upon 4 basic “Building Blocks” — Outdoor
Unit, Indoor Unit, Piping, and Controls — providing the
attributes of a central chilled water system but with the
simplicity of a split system.
+
Outdoor Unit
Applications
»» Multi-family
residences
»» Retail
»» Hotels
»» Office buildings
»» Schools, etc.
6
www.daikincomfort.com
Daikin VRV systems provide advanced solutions for almost
any large residential to commercial application. Available in
air-cooled or water-cooled solutions and heat recovery or heat
pump systems, VRV provides advanced heating and cooling
options with individual zone control for both open plan and tightly
grouped applications.
This makes it very flexible and ideal for energy-efficient
and comfortable cooling and heating of many types of
buildings such as banks, health care, skilled care, libraries,
storage facilities, conference centers, etc.
+
Indoor Unit
+
Piping
Controls
Inventor and leader in VRV systems since 1982
Unique products that make the difference
»» In efficiency
-- Variable Refrigerant Temperature technology
leading to excellent energy efficiency
-- Indoor units with advanced sensing technology
and optional self-cleaning air filter panel
»» In comfort
-- Variable Refrigerant Temperature
technology preventing cold droughts
-- 12 different indoor unit types and 63 models
-- Low sound indoor and outdoor units
»» In aesthetics
-- Stylish cassettes integrated in the ceiling
»» In control
-- intelligent Touch Manager — a mini-BMS/
Centralized Controller that integrates all
units in a cost-efficient system
-- Easy integrating with third party BMS
-- Dedicated control solutions for applications
such as offices, shops, hotels, schools, etc.
»» In system design
-- User friendly sizing and selection software
-- CAD drawings and Revit* families
-- Comprehensive engineering manuals
»» In after market support
-- Ceiling suspended cassettes
-- Nationwide field support organization
-- Elegant wall mounted units
-- 50+ product training facilities in North America
»» In installation
-- Automatic refrigerant charge function
-- Dedicated tech support team
»» In reliability
-- Self-addressing control system after installation
-- Refrigerant-cooled electronics in outdoor unit
-- VRV Configurator for simplified and
time saving commissioning
-- Extensive testing before new units leave the factory
-- Flexible connection possibilities for
indoor and outdoor units
-- ISO 9001 compliant manufacturing
-- Spare parts available in the US
-- One of the best warranties** in the industry
* Visit bim.daikincity.com for Revit families
** Complete warranty details available from your local distributor or
manufacturer's representative or at www.daikincomfort.com.
VRV Product Catalog
7
OVERVIEW
Why choose Daikin VRV?
OVERVIEW
Which VRV System Offers the Best Solution?
Air cooled or water cooled?
North
Air cooled
South
»» Fast and easy to install — no need for
additional components
»» Low maintenance costs
»» Can be installed both outdoors and indoors
»» Up to 38 tons capacity for one system
Components:
Outdoor unit
Indoor unit
Refrigerant
piping
Water cooled
»» Suitable for multi-story and large buildings because
of the almost unlimited possibilities of water piping
»» Not affected by outdoor
temperature/climate conditions
»» Reduce CO2 emissions thanks to the
possibility of geothermal energy as a
renewable energy source
Components:
Condensing unit
Indoor unit
Refrigerant piping
(Geothermal)
water loop
8
www.daikincomfort.com
OVERVIEW
Heat Recovery or Heat Pump?
VRV Heat Recovery
Extracted heat from one
room/zone delivers heat to
another room/zone
Cooling
Heating
»» Simultaneous heating AND cooling from one system
»» Efficient heating by transferring heat rejected by cooling
zones to those requiring heating.
»» Maximum individual comfort in all areas
»» Heating operation down to -22° F as standard.
Components:
Outdoor unit
Indoor unit
3-pipe
refrigerant
piping
Single and multi
Branch Selector boxes:
allows the individual
switching of indoor
units between heating
and cooling
VRV Heat Pump
»» For either heating OR cooling operation from one system
Components:
Outdoor unit
Indoor unit
2-pipe
refrigerant piping
VRV Product Catalog
9
OVERVIEW
Setting the Standards
Over 30 years of VRV history
Daikin invented the first VRV system in 1982 and has
continued to set standards in the industry and heighten market
expectations. Many of the current market expectations are:
»» Energy efficient inverter compressor
»» Modular system concept
»» Heat recovery function
»» Allow long piping lengths
»» Heating operation down to -13°F ambient air temperature as
standard
VRV was invented in 1982 as a result of the oil crisis around the
world in the 70's. Energy efficiency laws were passed by the
Japanese government. The Japanese government and Daikin
worked closely together — they looked at a chiller system;
pumps, and air handlers as well and how the pump circulates
water and how it uses a lot of power. So, they came up with
a concept to use refrigerant instead of water to circulate as
a heat transfer medium. The first VRV heat recovery system
was launched in 1991 implementing the landmark concept of
a heat pump chiller that circulates refrigerant instead of water.
»» Continuous heat during defrost
»» Auto charge at start up
VRF is launched
globally
1982
1st Heat Recovery
1987
World’s first VRV system
is developed
10
1990
Worlds first R410A VRV
heating down to -4°F EEV
in Branch Selector box
1991
First inverter VRV
www.daikincomfort.com
1998
2003
Continuous heating
during defrost, auto
charge 3280 ft. piping
2005
World’s first R407C VRV
auto addressing
(no rotary or dip switches)
2007
VRV IV
LAUNCHED
2014
2nd generation
VRV water cooled
technology
VRV AURORA™ World's first Air cooled
system to deliver
heating down to -22 ºF
2017
New VRV T-Series
water cooled
OVERVIEW
Our quality control is based on the idea that the added value we give to
products is quality, and that this quality is what customers are buying.
And each Daikin employee constantly puts quality ahead of everything else.
VRV Product Catalog
11
Daikin VRV
Daikin VRV sets the standard with the latest technology
and time saving commissioning & servicing
IENT
FIC
EF
LL
STA
IN
N
SIG
M
NT
DE
TO
AI
Larger capacity systems saves space
EAS
YT
O
OPTIMIZED
LIFE CYCLE
COST
E A SY
The features of a Daikin VRV
system, energy efficient and
easy to design, install, and
maintain, means that it is
designed to reduce the total
life cycle cost.
ENE
RG
Y
Optimized life cycle cost
A IN
E AS
YT
O
The VRV IV systems reduce installation cost and time as
compared to VRV III. We have increased the largest single
module to 14 tons and the largest double module to 28 tons,
while we made the footprint for the modules smaller. This
can mean up to a 32% reduction in installed space compared
to VRV III as it is possible to achieve greater capacity with
the same or smaller footprint. Again, Daikin has “Set the
Standard” by offering a wide system capacity range and
giving customers a reduction in installation costs coupled
with greater application flexibility.
VRV IV Heat Pump and Heat Recovery - Single, dual, and triple modules
6
8
10
12
14
Now up to 14 tons — 17% capacity increase*
CAPACITY - TONS
16
18
20
22
24
Now up to 28 tons — 40% capacity increase*
Now up to 14 tons — 17% capacity increase*
Now up to 28 tons — 40% capacity increase*
Heat Pump
Heat Recovery
OVERVIEW
Setting the Standards, Again
* Compared to Daikin VRV III models.
12
www.daikincomfort.com
26
28
30
32
34
Now up to 34 tons —
13% capacity increase*
36
38
Now up to 38 tons — 36% capacity increase*
VRV IV Heat Pump - Significantly Improved Efficiency
IEER improved by up to 28% over VRV III - Average of 11% over full range
Non - Ducted IEER
OVERVIEW
30
IEER
25
Significantly improved energy efficiency
20
VRV IV combines a number of substantial improvements in
system efficiency and function compared to VRV III.
unit sizes for ease of design, we have increased efficiency
15
through
improved heat transfer on all sizes.
Larger capacity units now utilize new inverter compressors
for all configurations. This improves overall efficiency and
allows the VRV IV to start with essentially no inrush power.
VRV IV uses a four-sided coil that presents a greater heat
exchange surface. While allowing the same footprint for all
is improved
III by
IV an
HP average of 11% with IEER Values
VRV over
III HPVRVVRV
now up to 28. For VRV IV Heat Recovery the improvements
are even greater with 20% average improvements and IEER
Values now up to 29.3.
6
8
10 12 14 16 18 20 22 24 26 28 30 32 34
Nominal
Capacity
The IEER (Integrated Energy
Efficiency)
for(Ton)
VRV IV Heat Pump
VRV IV Heat Pump
VRV
IV Heat Pump
- Significantly
Efficiency
IEER improved
by up to
28% over VRVImproved
III — average
of 11% over full range
VRV IV Heat Recovery
VRV improved
IV Heat Recovery
- Significantly
IEER
by up to 36%
over VRV III —Improved
average ofEfficiency
20% over full range
Non - Ducted IEER
Non - Ducted IEER
IEER improved by up to 28% over VRV III - Average of 11% over full range
IEER improved by up to 36% over VRV III - Average of 20% over full range
30
25
25
IEER
IEER
30
20
15
20
6
8
10 12 14 16 18 20 22 24 26 28 30 32 34
Nominal Capacity (Ton)
VRV III HP
15
6
8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38
Nominal Capacity (Ton)
VRV III HP
VRV IV HP
VRV IV HP
VRV IV Heat Recovery - Significantly Improved Efficiency
IEER improved by up to 36% over VRV III - Average of 20% over full range
Non - Ducted IEER
IEER
30
SCHE (Simultaneous Cooling and Heating Efficiency)
improved for VRV IV HR by up to 43% over VRV III —
25
Average improvement of 33% over full product size range.
20
15
6
8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38
Nominal Capacity (Ton)
VRV III HP
VRV IV HP
VRV Product Catalog
13
Daikin VRV
The Inventor of VRV is setting the standard again by introducing VRT
(Variable Refrigerant Temperature) – State-of-the-art energy-saving
technology for VRV
Refrigerant cycle (during cooling)
Customize your VRV for optimal annual efficiency
Refrigerant cycle during cooling
The new VRV system now features VRT technology. VRT
automatically adjusts refrigerant temperature to individual
building and climate requirement, thus further improving
annual energy efficiency and maintaining comfort. With this
excellent technology, utility costs are reduced.
Condenser
Indoor unit
heat exchanger
Evaporating
temperature raised –
Compressor
workload reduced
How is energy reduced?
Compressor
Evaporator
A standard VRF system, and previous VRV systems, utilize a
capacity based control logic where the system will adjust to
meet the capacity requirements of the space. With VRT Daikin
have optimized to focus not only on capacity but efficiency
and comfort.
to minimize the difference with the condensing temperature
and the evaporation temperature, respectively.
According to changes in the room heat load and the ambient
air temperature, the evaporating temp. (in cooling) and
condensing temperature (in heating) are automatically adjusted
This makes the compressors work less and also enables the
system to always maintain the ideal compressor speed so that
the Daikin VRV system can deliver the optimum efficiency.
Case study – Measured monthly energy usage for a VRV system without VRT and with VRT, installed in a European retail shop
5000
4500
4000
3500
3000
2500
2000
1500
1000
500
0
Year 1- VRV III without VRT
Year 2- VRV IV with VRT
Mar
Apr
May
Jun
Jul
Heating degree days and cooling degree days, that are
quantitative indications reflecting demand for energy to heat
or cool buildings, were the same for year 1 and year 2.
The basis to determine whether a specific day is a heating
degree day or a cooling degree day is the daily average
ambient air temperature. Even the average min/max ambient
air temperature were very similar for year 1 and year 2.
Aug
Sep
www.daikincomfort.com
Nov
Dec
86
Jan
Feb
Year 1 - Average max
Year 1 - Average min
Year 2 - Average max
Year 2 - Average min
68
50
32
14
14
Oct
VRT
54% annual
energy savings
Ambient air temperature
Ambient air temperature (ºF)
Monthly energy usage (kWh)
OVERVIEW
Setting the Standards, Again (cont.)
Mar Apr May Jun
Jul
Aug Sep
Oct Nov Dec Jan
Feb
OVERVIEW
Fine control to match user preference available through mode selection
Basic mode is selected to maintain optimal comfort. VRT is selected to save energy and prevent excessive cooling.
Capacity priority
Energy saving priority
Fixed Refrigerant Temperature
Variable Refrigerant Temperature
BASIC MODE
AUTO MODE
Fixed Te - Standard control
Floating target Te depending on heat load
HIGH SENSIBLE MODE
Fixed target Te
Selecting VRT enables operation to be optimised for either energy efficiency or rapid cooling.
Floating Te
POWERFUL MODE
Reaction speed
Very Fast
» Can boost capacity above
100% if needed.
The refrigerant temperature
can go lower in cooling than
the set minimum.
» Gives priority to very fast
reaction speed.
The refrigerant temperature
goes down fast to keep the
room setpoint stable.
Fixed Te
QUICK MODE
Reaction speed
Fast
» Gives priority to fast
reaction speed.
The refrigerant temperature
goes down fast to keep the
room setpoint stable.
MILD MODE
Reaction speed
Medium
ECO
ECO MODE
MODE
Unable to change Te
» Gives priority to efficiency.
The refrigerant temperature goes
down gradually giving priority to
the efficiency of the system
instead of the reaction speed.
Up to 28% improved seasonal
cooling efficiency vs. VRV III.*
*
In markets where cooling is dominant. VRT functionality
for heating operation improves the efficiency as well.
VRV Product Catalog
15
Daikin VRV
Piping flexibility —
More options for installation location
Extended Operation Range —
Heating operation down to -22° F
outdoor temperature and cooling
operation down to -4° F
The VRV IV provides very flexible piping possibilities.
These generous allowances outlined in the figure facilitate
an extensive variety of system designs.
Daikin VRV heat recovery systems can provide heating inside
the building even when the outside air temperature is as low
as -22° F as standard. Heat pump systems provide heating
down to -4° F. This enables enhanced application flexibility
and use of the system in colder regions.
»» 100 ft. maximum vertical difference between indoor units
provides greater flexibility for riser type piping layouts.
»» Allows for up to 12 floors to be served from a single
VRV System
»» Ideal for mid- to high-rise chiller or WSHP
Temperature Limits
replacement projects
VRV Air Cooled
Ambient
Heat Pump
Refrigerant Piping Limitations
Heat Recovery
AURORA Series Standard Operating Range
HEATING
SIMULTANEOUS
HEATING
23 F
COOLING
Temperature Limits
77 F
COOLING
122 F
10 F
-4 F
-13 F
-22 F
A
B
C
D
E
VIA technical cooling function
VIA extended capacity tables
Cooling operation for VRV IV Heat Pump single
module systems (RXYQ72/96/120/144/168T) can be
extended down to 10˚F, from the standard limitation
of 23˚F under defined conditions.
Contact your local Daikin manufacturer’s
representative or distributor for details.
PIPING
LIMITATIONS
Liquid Line
Max (ft)
WATER COOLED
VRV-IV VRV Aurora
VRV IV-S VRV IV-S VRV IV-W
Heat
Low
VRV T-Series
(3 Ton) (4 & 5 Ton) PC-Series
Recovery Ambient
Vertical
Drop
164
(295)¹
164
(295)¹
164
(295)¹
98
98
164
164
B
Between
IDU
100
100
(49)3
100
(49)3
33
49
49
98
113
110
C
Vertical
Rise
130
(295)1
130
(295)¹
130
(295)¹
98
98
130
130
100
95
90
D
From 1st
Joint
130
(295)2
130
(295)2
130
(295)2
130
130
130
E
Linear
Length
540
540
540
164
230
390
540
Total
Network
3280
3280
1640
820
984
980
980
120
80
Standard Range
for Continuous
Operation
70
Range
for
Operation
60
50
*EWT Below 50˚F
Requires Antifreeze
40
34
23*
20
14
50
59
70
80 82
90
Indoor Temperature (˚FWB)
*Limited to 27º F (for the PC series)
16
AIR COOLED
VRV-IV
Heat
Pump
A
VRV T-Series Water Cooled
Entering Water Temperature (˚F)
OVERVIEW
Setting the Standards, Again (cont.)
www.daikincomfort.com
130
(295)2
Setting adjustment on condensing unit required.
2
Application rules apply. Refer to Installation Manual for further details.
3
Possible refrigerant noise can be mitigated (via setting adjustments on ODU) when linear length
exceeds 390 ft.
1
OVERVIEW
Improved connection ratio flexibility
To properly match outdoor units with indoor units, VRV system
designers calculate the connection ratio.
Connection ratio 50%–200%
If a system has more combined indoor unit capacity index
than combined outdoor unit capacity index, the result is a
combination ratio that is greater than 100%. If the outdoor unit
combined capacity index is higher than the index for indoor
units, the combination ratio is less than 100%.
Most VRF systems do not allow the combination ratio to be
more than 130%. However, due to the advanced design of
the Daikin VRV IV system, the connection ratio is in most
cases allowed to be up to 200%.
Connection ratio =
Total capacity index
of the indoor units
Total capacity index
of the outdoor units
This generous connection ratio range enables increased
flexibility when a VRV system is designed.
Conditions of VRV indoor unit connection capacity
APPLICABLE VRV
INDOOR UNITS
Single outdoor units
Double outdoor units
Triple outdoor units
*
FXDQ, FXMQ-P,
FXAQ MODELS
OTHER VRV INDOOR
UNIT MODELS*
200%
200%
160%
130%
For FXFQ07, FXFQ09 models, maximum connection ratio is 130% for the entire range of outdoor units.
VRV Product Catalog
17
Daikin VRV
OVERVIEW
Setting the Standards, Again (cont.)
Advantages of 3-pipe technology
Daikin 3-pipe technology used in heat recovery systems
has dedicated refrigerant pipes for suction gas, liquid and
discharge gas. The dedicated refrigerant pipes provide
smooth and efficient refrigerant flow during all main modes of
operation and aid with the heating performance of the system
In a 2-pipe heat recovery system, where the gas and liquid
travel as a mixture in the refrigerant pipes, the condensing
temperature needs to be higher in order to separate the mixed
gas and refrigerant. The higher condensing temperature that
is needed means that the compressor has to work harder. In
addition, the disturbed refrigerant flow in large pipes on 2-pipe
system results in extra pressure drop which can negatively
impact the system capacity and efficiency.
Branch selector boxes
for ultimate flexibility
Providing flexibility and minimizing mechanical and electrical
installation costs, Daikin's branch selector boxes are ideal
for spaces that require individual heating and cooling control.
»» Extended range of product offerings with 1, 4, 6, 8, 10 and
12 port options
»» No drain or condensate consideration required
»» Unlimited number of unused ports per box or system
»» Reduced electrical and mechanical installation costs
»» Ultimate flexibility — choose multi-port or single-port styles
to customize your design
»» Up to 72% reduction in footprint, as compared to previous
generation models
»» Up to 17% lower sound levels compared to current
VRV III models
»» Up to 65% reduction in weight, as compared to previous
generation models
18
www.daikincomfort.com
OVERVIEW
New efficient technology from Daikin
7mm Coil — 3 Row
Improved heat exchanger efficiency
Corrosion protected coil
The VRV IV comes as standard with a
corrosion protected coil — 1000 hr of salt
fog testing according to ASTM B117.
Inverter board cooled
by refrigerant circuit
Minimum influence on
electronics from ambient
temperature.
Section of the
coil in the unit is
permanently set as
condenser for cooling
of the inverter board.
4-sided heat exchanger coil
50% more heat exchanger surface than
VRV III — more capacity and higher
efficiencies from the same footprint
Inverter board cooled by refrigerant circuit
An inverter Printed Circuit Board (PCB) cooled with the
liquid refrigerant circuit increases allows more airflow to the
VRV IV cooling coil to increase efficiency and also minimizes
any influence on the inverter board from ambient temperatures.
4-Sided heat exchanger coil for efficiency
A 4-sided condenser with up to 3 coil rows utilizing 7 mm tubing
means even though the VRV IV has similar footprint as the
VRV III, the efficiency is increased while the refrigerant charge
is less in most models.
Advanced compressor technology
Daikin J Type Inverter Scroll Compressor has a 50% thinner
and a 20% higher scroll blade than the previous generation,
which is realized by adapting a newly developed material. This
technology increases compression volume by 50%. With the
new J Type Compressor and utilizing all inverter compressors,
the Maximum Overload Protection (MOP) is reduced by up
to 29% compared to VRV III.
50% thinner blade
50% more
compression
volume
20% higher blade
2.4 TIMES STRONGER
than previous generation
VRV Product Catalog
19
Daikin VRV
OVERVIEW
Setting the Standards, Again (cont.)
Outdoor unit sequencing technology
Automatic sequencing operation
During start-up, Daikin VRV IV unit sequencing operation will be automatically enabled to ensure balanced operation of each
outdoor unit to improve longevity of equipment and stable operation.
Stage 1
Stage 2
Stage 3
Automatic
sequencing
1
2
3
Priority
Automatic
sequencing
3
1
2
Priority
2
3
1
Priority
Double backup operation functions responding
resiliently to various unexpected situations
Double backup operation functions
Daikin VRV IV system boasts double backup operation functions, which can secure the use of air conditioners in this area to
the greatest extent by emergently enabling double backup operation functions even if failure occurs in a set of air conditioning
equipment. In the event of a failure, emergency operation can be conveniently enabled to allow the remaining system to
operate in a limited fashion.
Unit backup operation function
Compressor backup operation function
If malfunction occurs in an outdoor unit...
If malfunction occurs in a compressor...
Emergency operation can be conveniently set and enabled by
the remote controller for indoor unit (for systems composed
of two or more outdoor units).
Emergency operation can be easily set and enabled
by the outdoor unit.
20
www.daikincomfort.com
OVERVIEW
With the VRV IV heat pump and heat recovery systems, the Daikin
brand is one of the most extensive lines of heating and cooling systems
in North America.
VRV Product Catalog
21
OVERVIEW
Daikin VRV
Setting the Standards, Again (cont.)
VRV outdoor units assembled in the U.S.A.
The VRV IV is the first variable refrigerant flow (VRF)
system to be assembled in North America. With a state of
the art production line, local / in house preparation, tooling,
processing and construction of heat exchangers, refrigerant
» Extensive local inventory
and short lead times.
» Typically, 98% of replacement
parts can be shipped in
approximately 48 hours.
22
www.daikincomfort.com
cycle assemblies, sheet metal parts, electrical box, etc.,
we can react quickly to changes in the market-place and truly
optimize the product for the North American market.
OVERVIEW
VRV system configuration and commissioning
»» The VRV configurator is an advanced software solution that
»» Multiple systems at different sites can be managed
allows for easy system configuration and commissioning.
in exactly the same way, thus offering simplified
commissioning for key accounts.
»» Less time is required on the roof configuring the
»» Initial settings on the outdoor unit can be easily retrieved.
outdoor unit.
Simplified commissioning
Retrieve initial system settings
Outstanding 10-Year Parts and Compressor Limited Warranties*
replacement
compressor
Outstanding warranty * with 10-Year
Replacement Compressor Limited
Warranty and 10-Year Parts Limited
Warranty as standard ensures our
confidence in our new VRV IV.
VRV Product Catalog
Complete warranty details available
from your local Daikin manufacturer’s
representative or distributor or online at
www.daikincomfort.com.
* 23
Daikin VRV
OVERVIEW
What does a VRV installation mean to you?
Consulting engineers
Building owners
Daikin's VRV IV technology maximizes flexibility and leads the
way in customization to match individual building requirements
in comfort and energy — all designed to reduce the total life
cycle costs.
VRV IV is the ultimate in customized comfort and intelligent
control tailored to your individual needs and used to maximize
energy efficiency.
»» Maximum flexibility to meet customer requirements
»» Advanced software tools assist with system design
»» Optimized life cycle cost
»» No more cold droughts with variable refrigerant temperature
»» Single point of contact for the design of your climate system
»» Integrated system, combining air conditioning, heating,
ventilation, etc., enables optimized system function
»» Multiple systems can be managed in exactly the same way
for key accounts
»» Dedicated after-sales service to ensure fast on-site support
See how you can profit from
Daikin’s flexible and efficient
product range.
24
www.daikincomfort.com
OVERVIEW
Installers
Architects
Daikin VRV IV sets the standard with state-of-the-art
technology and time-saving commissioning and servicing.
»» Indoor units with a sleek and sophisticated design
»» Space efficient outdoor units
»» Low sound levels for both indoor and outdoor units
»» Wide range of indoor units to allow installation in
»» Simplified and time-saving commissioning with
VRV configurator
»» Unique range of single and multi Branch Selector boxes
reduce installation time compared to previous generation
most environments
»» Wide range of outdoor units (up to 38 Tons for
heat recovery)
»» One supplier equals one point of contact
»» Maximum flexibility to meet customer requirements
»» Customized training to maximize expertise
VRV Product Catalog
25
Daikin VRV
OVERVIEW
Vertical Market Applications
VRV for offices and banks
VRV for hotels
Our office solution offers:
Our hotel solution offers:
»» Increased occupant productivity with individual zone control,
»» Energy efficient systems capable of simultaneous heating
low sound levels & tight temperature control
and cooling.
»» Optimized energy efficiency
»» Simple maintenance — low operational cost
»» Modular system allowing cost effective
»» Ultra-quiet guest room solutions discrete and
simple to control.
»» Flexible installation options lowering installation complexity,
out-of-hours operation
»» Integrated ventilation solutions allowing high indoor
air quality
»» Complete Daikin Building Management System for office
building management with Intelligent Touch Manager
»» Remote monitoring with email alerts
»» Self-cleaning filters yielding operational and maintenance
cost savings
»» Intelligent sensors on round flow cassette maximizing
efficiency by innovative occupancy sensing features
Heating and cooling
26
Ventilation
www.daikincomfort.com
costs and space requirements than most traditional
HVAC systems
»» Inverter technology creating the perfect guest room
environment by regulating temperature swings and humidity
»» Centralized control with the iTouch Manager improving
owner / management operational capabilities
»» Seamless integration & compatibility with industry
acclaimed INNCOM systems delivering combined benefits
in guest operations and experience for both guests and
management team
Intelligent control system
OVERVIEW
VRV for retail and restaurants
VRV for schools
Our retail solutions offer:
Our school solution offers:
»» Scalable project opportunities with modular design
»» Individual zone control for advanced zoning capabilities
»» Enhanced efficiency in retail chain operations and energy
»» Flexible, scalable total HVAC solution for school classrooms,
usage from Daikin's complete Building Management
System with Intelligent Touch Manager
»» Centralized building control & autonomy from VRV remote
commissioning and management capability
»» 10-Years Limited Parts and Compressor Warranty*
common areas and administrative offices
»» Over 12,000 Daikin VRV systems in schools in
North America
»» Quiet operating sound levels as low as 28 dB(A)
»» Minimal occupant air temperature variations
»» Advanced zoning capabilities with user-friendly and
intuitive controls
»» Modular in design accommodating unique school and
classroom spaces
»» Combined benefits of energy and operations efficiency
for both school administrators & maintenance staff
»» 10-Year Limited Parts and Compressor Warranty*
Complete warranty details available from your local
Daikin manufacturer’s representative or distributor or
online at www.daikincomfort.com.
* VRV Product Catalog
27
28
www.daikincomfort.com
Product Portfolio
VRV Product Catalog
29
Product Portfolio
Outdoor Units
PRODUCT PORTFOLIO
VRV AURORA™ Heat Recovery
Air-Cooled
»» VRF Industry’s first air cooled system
that delivers heating down to -22°F
(-30°C) as standard
»» Hot gas base pan circuit allows installation
without an additional drain pan heater
»» Designed to provide continuous heating
during defrost and oil return1
»» Engineered with Daikin vapor injection compressor
for optimized part load efficiencies
VRV IV-S systems are equipped with
built-in intelligence which provide
independent zoning control with
maximum flexibility and energy savings.
With the ability to connect up to
ten indoor units to one outdoor unit, the space-saving
VRV IV-S system is ideal for most light commercial and
residential applications.
1
Multi modules only for continuous heating during defrost
Heat Recovery
»» Fully integrated solution with heat
recovery offers high efficiencies
with IEER values up to 29.3
»» Total comfort solution for heating,
cooling, ventilation, and controls
»» Outstanding warranty* with
10-Year Compressor and Parts Limited Warranty as standard
»» Perfect personal comfort for guests / tenants
via simultaneous cooling and heating
»» Incorporates VRV IV standards and technologies such as
variable refrigerant temperature and all inverter compressors
»» Unique range of single and multi-port branch selector boxes
»» Heating function down to -13°F ambient air temperature
»» Daikin VRV IV is the first variable refrigerant flow
(VRF) system to be assembled in North America.
Heat Pump
»» Total comfort solution for heating,
cooling, ventilation and controls
»» Energy efficiency values (IEER) up to 28.0
»» Incorporates VRV IV standards and
technologies such as variable refrigerant
temperature and all inverter compressors
»» Best-In-class warranty* with 10 year compressor
and parts limited warranty as standard
»» Daikin VRV IV is the first variable refrigerant flow
(VRF) system to be assembled in North America.
Heat Recovery
»» Advanced continuous heating during
defrost cycle and oil return for single
module systems
»» Variable Refrigerant Temperature
(VRT) control
»» Extended operating range with heating
function down to -4°F ambient air temperature
30
www.daikincomfort.com
»» Available in 3, 4 and NEW 5 ton modules
»» Increase in efficiency up to 18 SEER & 10.5+ HSPF
»» Year round comfort and energy savings delivered
by VRT technology
»» Broader diversity with ability to connect up to 9 indoor units
»» Space saving design with under 39”** height.
Over 25% smaller as compared to VRV III-S
»» Easier to install with over 39% weight reduction vs VRV III-S
»» Low sound levels for comfort
»» Higher reliability with Daikin’s swing compressor
»» Dependable operation in extreme ambient conditions
up to 122°F
»» Added safety and peace of mind with optional
auto changeover to auxiliary heat
»» Backed by a best in class 10-Year Parts Limited Warranty*
** Varies based on condensing unit model selected
VRV T-Series Water Cooled Condensing Unit
Heat Pump/Heat Recovery
»» Flexible System design with increased
diversity up to 150%†
»» Can be applied to both geothermal and
boiler/tower applications as standard
with condenser water inlet temperature
as low as 14°F† in heating and 23°F†
in cooling is possible
»» Triple-stack capable to deliver up to 36 tons in just under
10.5 feet ceiling height thanks to the compact design
»» Engineered with heat rejection cancellation technology†
to eliminate mechanical room conditioning requirements
»» 2-9V variable water flow control logic† as standard to
increase waterside system operational efficiencies
»» Drop-down switch box for easy service to key components
»» Field selectable top or front refrigerant connections for
flexible and easy installation
Conditions/rules apply. Refer to Installation and Engineering Manual for
further details.
†
* Complete warranty details available from your local Daikin manufacturer’s
representative or distributor or online at www.daikincomfort.com.
VRV IV Heat Recovery
VRV III PC Heat Recovery
3
4
5
6
CAPACITY (TONS)
8 10 12 14 16 18 20 21 22 24 26 28 30 32 34 36 38
n
n
RELQ-T
n
n
n
n
Multi modules only for continuous heating
during defrost
1
»»Best efficiency & comfort solution
»»Fully integrated solution with heat recovery
for high efficiencies with IEER of up to 29.3
»»Covers all thermal needs of a building
via a single point of contact for accurate
temperature control
»»The perfect personal comfort for
guests/tenants via simultaneous
cooling and heating
»»Incorporates VRV IV standards &
technologies such as Variable Refrigerant
temperature and all inverter compressors
»»Widest range of Branch Selector boxes
on the market
REYQ-T
»»Advanced continuous heating during
defrost cycle and oil return for single
module systems
»»Variable Refrigerant Temperature
(VRT) control
»»E xtended operating range with
heating function down to - 4°F
ambient air temperature
REYQ-PC
»» Daikin’s solution for comfort
& low energy consumption
»» Covers all thermal needs of a building
via a single point of contact for accurate
temperature control
RXYQ-T
n
n
n
n
n
n
n
n
n n*
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
VRV IV-S
Heat Pump
RXTQ-TA
»»Single phase technology
»»Space saving solution without
compromising on efficiency
»»For residential and light
commercial applications
VRV T-Series Water Cooled Condensing Unit
Heat Recovery / Heat Pump
VRV IV Heat Pump
Air Cooled
Water Cooled
»» VRF Industry’s first air cooled system that
delivers heating down to -22°F (-30°C) as
standard
»» Hot gas base pan circuit allows installation
without an additional drain pan heater
»» Designed to provide continuous heating
during defrost and oil return1
»» Engineered with Daikin vapor injection
compressor for optimized part load
efficiencies
PRODUCT NAME
PRODUCT PORTFOLIO
VRV AURORA™ Heat Recovery
TYPE MODEL FEATURES
»»Ideal for high rise buildings, using water
RWEQ-T
as heat source
»»Enables use of geothermal energy as a
renewable energy source
»»Flexible System design with increased
diversity up to 150%***
»»Triple-stack capable to deliver up to 36 tons
in just under 10.5 feet ceiling height thanks
to the compact design
»»Engineered with heat rejection cancellation
technology*** to eliminate mechanical room
conditioning requirements
»»2-9V variable water flow control logic***
as standard to increase waterside system
operational efficiencies
n
n
n
n ** n
n
n
n
n
n
n
n
n
n
n
* 208-230V/3Ph/60Hz only. ** 6-ton model is a PC-Series model. Some features may not be available for this model. *** Conditions/rules apply. Refer to Installation and Engineering Manual for further details.
VRV Product Catalog
31
Product Portfolio (cont.)
Indoor Units
Ducted
FEATURES
PRODUCT NAME
FXMQ-PBVJU
DC-Ducted Concealed
Ceiling Unit
»» Energy efficient due to the DC fan motor
»» Ideal to use together with the optional Daikin Zoning Kit, DZK
»» Enhanced indoor air quality and LEED ready with MERV 13 filter options
»» Flexible ductwork design with ESP capabilities up to 0.8" W.G.
»» Installation flexibility with a low profile, compact design at less than 12" in height
FXDQ-MVJU
Slim-Duct, Built-In
Concealed Ceiling Unit
»» Slim height, at only 7- 7⁄ 8"
»» Washable filter included
»» Low sound level
»» Factory shipped for rear air inlet —field convertible to bottom air inlet
»» Condensate pump with vertical lift of up to 21-5 ⁄ 8" included as standard
Multi-Position Air Handling Unit
»» Ideal replacement for fan coils, geothermal heat pumps or traditional splits systems
»» Upflow and horizontal right installation is permitted
»» ECM fan motor provides energy efficiency
»» Wide line up of electric heat (field installed) options from 3kW to 20kW
»» Design flexibility with a capacity range up to 96 MBH
»» Improved ductwork and filtration flexibility with high CFM and ESP capabilities
»» Low profile design of less than 19" high to reduce required installation space
»» Ideal for Hotels, Schools, Retail
FXMQ-MVJU
Concealed Ceiling Unit
(Medium Static)
»» Ideal for installation beneath a window
»» Requires minimal installation space
»» Fitted with a washable long-life filter
»» Space-saving unit can be freestanding or wall-mounted
FXNQ-MVJU9
Concealed FloorStanding Unit
»» True 360° Airflow and three room sensors enables optimized occupant comfort
»» Energy efficient with DC fan motor and auto-logic that adjusts fan speed
»» Optional self-cleaning filter panel to further increase efficiency and reduce maintenance
»» Increased indoor air quality with high efficiency filter options and ventilation connection kit
»» Very flexible with 18 different possible airflow patterns
FXFQ-TVJU
Round Flow
Sensing Cassette
Duct-Free
PRODUCT PORTFOLIO
TYPE MODEL
32
FXTQ-TAVJU
»» Very low unit height of under 8"
4-Way Ceiling-Suspended
»» Optional Sensor Kit enables input from three room sensors
Cassette
»» Stylish unit blends easily with any interior
»» Individual air louver control
FXUQ-PVJU
»» Fits in a standard 2' x 2' ceiling grid.
»» Sound pressure levels are as low as 29 dB(A)
2' x 2' 4-Way
»» Space-saving depth of units requires only 11.6" of ceiling space
Ceiling-Mounted Cassette
»» Easy-to-clean grille, washable long-life filter
»» Simple installation with an easy-to-fit decoration panel
FXZQ-MVJU9
FXEQ-PVJU
»» Only 7- 7⁄ 8" in height and a width of 18-½" making it possible to use this style of indoor unit in the tightest of spaces
Ceiling-Mounted Cassette »» The unit is equipped with both horizontal and vertical louvers to optimize the airflow and throw to suite your room design
(Single flow)
»» The indoor unit can be set to 5 predetermined fan speeds which allows for optimum and comfortable airflow
»» Factory installed condensate pump with a lift capacity of up to 33- 7⁄16" (measured from the bottom of the unit)
FXHQ-MVJU
Ceiling-Suspended Unit
»» One of our slimmest indoor units, less than 8"
»» Wide air discharge outlet distributes a comfortable airflow throughout the entire space
»» Innovative stream fan technology keeps sound pressure levels low
»» Smooth flat louver design makes cleaning simple
»» Long-life filter is standard
FXAQ-PVJU
Wall-Mounted Unit
»» Auto-swing mechanism ensures efficient air distribution via louvers
»» Wide air discharge outlet distributes a comfortable airflow throughout the entire space
»» Horizontal louvers and front panel can be easily removed for cleaning
»» Drain pipe can be easily hidden from sight
»» Compact and stylish design
FXLQ-MVJU9
Floor-Standing Unit
»» Ideal for installation beneath a window
»» Unit requires minimal installation space
»» Fitted with a washable long-life filter
»» Remote-control options available
»» Space-saving unit can be freestanding or wall-mounted
www.daikincomfort.com
7.5
0.6
9.5
0.75
12
1
15
1.25
18
1.5
24
2
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
CAPACITY
30
2.5
36
3
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
42
3.5
n
48
4
54
4.5
n
n
n
n
60
5
72
6
96
8
n
n
PRODUCT PORTFOLIO
MBH
TON
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
VRV Product Catalog
33
Product Portfolio (cont.)
Accessories
PRODUCT PORTFOLIO
Branch Selector Boxes
Providing flexibility and minimizing mechanical and electrical installation costs, Daikin's branch selector boxes that are used
in Heat Recovery systems, are ideal for spaces that require individual heating and cooling control.
NUMBER OF BRANCHES / MAXIMUM TOTAL CAPACITY INDEX (KBTU/H)
BSQ36TVJ
1/36
BSQ60TVJ
1/60
BSQ96TVJ
1/96
BS4Q54TVJ
4/144
BS6Q54TVJ
6/216
BS8Q54TVJ
8/290
BS10Q54TVJ
10/290
BS12Q54TVJ
12/290
REFNET
REFNET joints distribute correct flow of refrigerant
in every branch of the piping network.
REFNET Joint
VRV IV Heat Pump
OPTIONAL ACCESSORIES
REFNET header
RXYQ72T
RXYQ96T
RXYQ120T
RXYQ144T
RXYQ168T
KHRP26M22H (max. 4 branch)
KHRP26M33H (max. 8 branch)
KHRP26M22H (max. 4 branch)
KHRP26M33H (max. 8 branch)
KHRP26M72H (max. 8 branch)
KHRP26A22T
KHRP26A33T
KHRP26A22T
KHRP26A33T
KHRP26M72TU
Distributed piping
REFNET joint
Outdoor unit multi connection piping kit
—
REFNET Header
RXYQ192T
RXYQ216T
RXYQ240T
RXYQ360T
RXYQ264T
RXYQ384T
RXYQ288T
RXYQ408T
RXYQ312T
RXYQ336T
KHRP26M22H (max. 4 branch)
KHRP26M33H (max. 8 branch)
KHRP26M72H (max. 8 branch)
KHRP26M73H (max. 8 branch)
KHRP26A22T
KHRP26A33T
KHRP26M72TU
KHRP26M73TU
BHFP22P100U
BHFP22P151U
VRV IV Heat Recovery / VRV AURORA™ Heat Recovery
OPTIONAL ACCESSORIES
REFNET header
REYQ72T
REYQ96T
REYQ120T
REYQ144T
REYQ168T
RELQ72T
RELQ96T
KHRP25M33H9 (max. 8 branch)
KHRP25M33H9 (max. 8 branch)
KHRP25M72H9 (max. 8 branch)
KHRP25A22T9
KHRP25A33T9
KHRP25A22T9
KHRP25A33T9
KHRP25M72TU9
Distributed piping
REFNET joint
Outdoor unit multi connection piping kit
34
RELQ120T
www.daikincomfort.com
—
REYQ192T
REYQ216T
REYQ240T
REYQ264T
REYQ288T
REYQ312T
REYQ336T
RELQ144T
RELQ192T
RELQ240T
REYQ360T
REYQ384T
REYQ408T
REYQ432T
REYQ456T
KHRP25M33H9 (max. 8 branch)
KHRP25M72H9 (max. 8 branch)
KHRP25M73H9 (max. 8 branch)
KHRP25A22T9
KHRP25A33T9
KHRP25M72TU9
KHRP25M73TU9
BHFP26P100U
BHFP26P151U
PRODUCT PORTFOLIO
VRV III PC Heat Recovery
OPTIONAL ACCESSORIES
REYQ72PC
REFNET Header
KHRP25M33H9 (max. 8 branch)
Distributed piping
KHRP25A22T9
KHRP25A33T9
REFNET Joint
REYQ96PC
REYQ120PC
REYQ144PCTJ
KHRP25M33H9 (max. 8 branch)
KHRP25M72H9 (max. 8 branch)
KHRP25A22T9
KHRP25A33T9
KHRP25M72TU9
VRV T-Series Water Cooled Heat Pump / Heat Recovery and VRV-IV-S
UNIT MODEL
NUMBER
REFNET
Header
REFNET
Joint
VRV T-SERIES WATER COOLED
RWEQ192,216,240,
RWEQ120TATJU
RWEQ144TATJU
264,288TATJU
RWEQ120TAYDU
RWEQ144TAYDU
RWEQ192,216,240,
264,288TAYDU
RWEQ96TATJU
RWEQ96TAYDU
VRV-IV-S
RWEQ312,336,360TATJU
RWEQ312,336,360TAYDU
RXTQ36TAVJ9
RXTQ48TAVJU
RXTQ60TAVJU
Heat
Pump
KHRP26M22HR (Max 4 branch)
KHRP26M33H9 (Max 8 branch)
KHRP26M22H9 (Max 4 branch),
KHRP26M33H9 (Max 8 branch)
KHRP26M72H9 (Max 8 branch)
KHRP26M22H9 (Max 4 branch), KHRP26M33H9 (Max 8 branch)
KHRP26M72H9 (Max 8 branch), KHRP26M73HU9 (Max 8 branch)
KHRP26M22H9 (Max. 4 branch)
KHRP26M33H9 (Max. 8 branch
Heat
Recovery
KHRP26M33H9 (Max 8 branch)
KHRP25M33H9 (Max 8 branch)
KHRP25M72H9 (Max 8 branch)
KHRP25M33H9 (Max 8 branch), KHRP25M72H9 (Max 8 branch)
KHRP25M73HU9 (Max 8 branch)
__
Heat
Pump
KHRP26A22T9, KHRP26A33T9
KHRP26A22T9, KHRP26A33T9, KHRP26M72TU9
KHRP26A22T9, KHRP26A33T9, KHRP26A72UT9, KHRP26M73TU9
KHRP26A22T9
Heat
Recovery
KHRP25A22T9, KHRP25A33T9
KHRP25A22T9, KHRP25A33T9, KHRP25M72TU9
KHRP25A22T9, KHRP25A33T9, KHRP25A72TU9, KHRP25M73TU9
__
Heat
Outdoor
Pump
Unit Multi
Piping
Heat
Connection
Recovery
Kit
__
BHFP22T84U
BHFP22T126U
__
__
BHFP26T84U
BHFP26T126U
__
Hail Guard Kit for VRV IV
The optional hail guard kit for VRV IV enables optimal airflow
for efficient heat transfer while providing condenser coil
protection from hail damage in severe climates. Each hail
guard kit, that is field installed, consists of 4 panels (Right,
Left, Front and Back).
KIT PART
NUMBER
VRV4HGS-K1
VRV4HGL-K1
QUANTITY OF KITS PER VRV IV OU MODEL
R_YQ72T
1
R_YQ96-168T
1
R_YQ192T
1
1
R_YQ216-336T R_YQ360-456T
2
3
VRV Product Catalog
35
Product Portfolio (cont.)
Accessories (continued)
PRODUCT PORTFOLIO
DZK (Daikin Zoning Kit)
The optional DZK increases the flexibility of the Daikin VRV and SkyAir systems in both residential and
commercial applications by adding a Zoning Box to an indoor unit fan coil (FXMQ-P or FBQ-P series,
respectively) allowing several separate ducts to supply air to different individually controlled zones.
The DZK BACnet Gateway module will work with any BACnet /IP compatible Building
Management System.
®
®
DAIKIN ZONING KIT (DZK) – KIT STRUCTURE AND GENERAL TECHNICAL DATA
Zoning Box with Control Box
DZK Product Number
DZK030E4-3
DZK030E5-3
DZK048E4-3
DZK048E6-3
Wired Thermostat Wireless Thermostat Wireless Lite Thermostat
DZK-MTS-3-W
DZK-ZTS-3-W
DZK-LTS-3-W
BACnet Interface
DZK-BACNET-3
Daikin VRV controls
Optimized for VRV technology, Daikin controls provide highly scalable solutions for all applications and budgets. VRV controls
offer solutions to meet your project controls needs from individual zone control with local controllers to centrally controlling
the building with Centralized Controllers and/or interfacing with Building Management Systems (BMS) for comfort control in
an easily managed and operated system.
PROJECT REQUIREMENTS
DAIKIN VRV CONTROLS
Navigation
Simplified Remote
intelligent
Controller
Remote Controller
Touch Controller
Individual zone control
Independent cool and heat setpoints
Individual zone control with weekly
programmable scheduling
Basic central point on/off control of all
air handling units
Advanced multi-zone control of small to
medium size projects
Advanced multi-zone control of large
commercial projects
Advanced multi-zone control with scheduling
logic and calendar
Automatic cooling/heating changeover
for heat pump systems
Single input batch shutdown of all connected
air handlers
Web browser control and monitoring
via Intranet and Internet
E-mail notification of system alarms and
equipment malfunctions
Multiple tenant power billing for shared
condenser applications
Temperature set-point range restrictions
Graphical user interface with floor plan layout
Start/stop control of ancillary
building systems*
Daikin VRV integration with BACnet
based automation systems
Daikin VRV integration with LonWorks
based automation systems
Daikin VRV integration with Modbus based
automation systems
*
n
intelligent
Touch Manager
LonWorks ®
Interface
Modbus ®
Interface
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
Requires one or more DEC102A51-US2 Digital Input/Output units or WAGO DO module (for use with iTM only).
n Native application or feature for this device. n Dependent upon capabilities of the third party energy management system
36
BACnet ®
Interface
www.daikincomfort.com
n
n
VRV Product Catalog
PRODUCT PORTFOLIO
The configurable display and operation buttons on the Navigation
Remote Controller will provide as much or as little control as the
installed VRV system requires.
37
Product Portfolio (cont.)
Accessories (continued)
PRODUCT PORTFOLIO
Network solutions
TYPE
Screen
Integration
Control
Monitoring
Options
Other
38
iTC
Layout screen
Touch screen
Mini BMS for heating, air conditioning applied systems
and refrigeration units (BACnet and WAGO)
3rd party equipment integration (BACnet and WAGO)
Basic control functions: on/off, set point setting,
air flow settings, operation mode
Temperature limitation
Setback
Automatic changeover
Weekly schedule and special day pattern
Timer extension
Forced off
Basic control functions: ON/OFF status,
operation mode, set point temp.
Filter status
Malfunction code
History (operation, malfunction…)
Visualization
PPD
Web access and control
HTTP option
BACnet Client
BACnet Server
Interlock
Maximum number of indoor unit groups
www.daikincomfort.com
iTM
LonWorks®
BACnet®
Modbus®
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
64
4 x 64
16
n
n
n
Std
n
n
n
n
n
2 x 64
8 x 64
Daikin’s Outside Air Processing Unit can combine fresh air
treatment and air conditioning, supplied from a single system.
The compact Energy Recovery Ventilator is designed to improve
indoor air quality while reducing the overall HVAC system power
VRV Refrigerant Piping
VRV Control Wiring
High Efficiency Filter (MERV 8 and MERV 13)
Ventilation System
Power Supply
Airflow Rate
consumption. This is achieved by providing fresh outside air
and recovering waste heat from exhaust air leaving the
conditioned space.
OUTSIDE AIR PROCESSING UNIT, FXMQ-MFVJU
ENERGY RECOVERY VENTILATOR, VAM-GVJU
Connectable
Not connectable
Connectable
Option
Air supply
V/ph/Hz
CFM
Not available
Air supply and Air exhaust
208-230/1/60
635
988
1236
300/300/170
470/470/390
600/600/500
1200/1200/930
Daikin’s air treatment systems —
creating a better air quality environment.
VRV Product Catalog
39
PRODUCT PORTFOLIO
Air treatment systems
40
www.daikincomfort.com
Indoor Units
VRV Product Catalog
41
Indoor Units
INDOOR UNITS
Designed for absolute comfort and versatility, Daikin's wide selection of
ducted and duct-free indoor units with a sleek and sophisticated design
provides zoning flexibility and comfort control for almost any application.
As many as 64 separate indoor units can be connected to a refrigerant circuit with a single outdoor
unit of up to 38 tons capacity. The Daikin VRV indoor unit range is one of the widest on the market,
offering no less than 12 stylish and elegant indoor units types in 63 different models — all designed
to maximize comfort, minimize operating sound and simplify installation and servicing.
Indoor unit models include round flow ceiling mounted
cassette, ceiling concealed ducted, ceiling suspended, wall
mounted and floor standing models.
The Round Flow sensing cassette now includes an optional VRF
industry first self-cleaning filter, which automatically cleans itself
daily (user adjustable), leading to yearly energy savings of up to 50%.
42
www.daikincomfort.com
Dust from the filter is collected in the unit for easy and quick
removal (when indicated) with a standard vacuum cleaner.
Designed to fit rooms of any size and shape, Daikin indoor units
are also user friendly, ultra reliable, easy to control and quiet
in operation.
INDOOR UNIT TYPE
MBH
TONS
7.5
0.6
09
0.75
12
1
15
1.25
CAPACITY
18
24
1.5
2
30
2.5
36
3
42
3.5
48
4
54
4.5
60
5
72
6
96
8
FXMQ-PBVJU
DC-Ducted Concealed Ceiling
(Medium Static)
FXTQ-TAVJU
Multi-Position Air Handling Unit
(Upflow, Downflow, Horizontal Left
and Horizontal Right)
INDOOR UNITS
DUCTED
FXDQ-MVJU
Slim Duct Built-In
Concealed Ceiling Unit
FXMQ-MVJU
Concealed Ceiling Unit
(Medium Static)
FXNQ-MVJU9 Concealed
Floor- Standing Unit
FXFQ-TVJU
Round Flow Sensing Cassette,
Ceiling Mounted
FXUQ-PVJU
4-Way Blow
Ceiling-Suspended Cassette
DUCT-FREE
FXZQ-MVJU9
2' X 2' 4-Way
Ceiling-Mounted Cassette
FXEQ-PVJU
Ceiling-Mounted Cassette
(Single Flow)
FXHQ-MVJU
Ceiling-Suspended Unit
FXAQ-PVJU
Wall-Mounted Unit
FXLQ-MVJU9
Floor-Standing Unit
Comfort cooling/heating (11 types 57 models)
Condensate pump standard
Outside air connection possible
VRV Product Catalog
43
Indoor Units Overview
What are your choices?
FXMQ-MVJU
Concealed Ceiling Unit (Medium Static)
Ceiling mounted DC-Ducted
unit — ideal for small to large
spaces in need of a concealed
air-conditioning system.
Ideal unit for larger open
space floor plans usually
found in offices, retails,
hotels or education facilities.
FXDQ-MVJU
Slim Duct Built-In Concealed Ceiling Unit
FXNQ-MVJU9
Concealed Floor-Standing Unit
Slim duct built-in concealed
unit with low profile and low
sound level.
Floor-standing unit that can
easily be installed along a
perimeter wall — or concealed.
FXTQ-TAVJU
Multi-Position Air Handling Unit
FXFQ-TVJU
Round Flow Sensing Cassette, Ceiling Mounted
Vertical air handling unit ideal
for both residential and light
commercial applications.
It has upflow,
downflow,
horizontal
left and
horizontal right
possibilities.
Ideal for open plan
applications such as
classrooms and offices
where adaptive comfort
control is preferred. Provides
excellent comfort level,
energy efficiency, and
flexibility due to advanced
control functions.
INDOOR UNITS
FXMQ-PBVJU
DC-Ducted Concealed Ceiling (Medium Static)
44
www.daikincomfort.com
FXAQ-PVJU
Wall-Mounted Unit
Perfect solution for rooms
without a false ceiling, or
minimal space above a false
ceiling, where adaptive
comfort control is preferred.
Unit ideal for cooling or
heating smaller zones
such as stores, offices and
restaurants. Compact and
stylish design.
FXZQ-MVJU9
2'x2' 4-Way Ceiling-Mounted Cassette
FXLQ-MVJU9
Floor-Standing Unit
2'x2' 4-way Cassette best
for open plan applications
such as classrooms, offices
and retail.
Great way to save space.
The floor-standing units can
easily be installed along a
perimeter wall.
FXHQ-MVJU
Ceiling-Suspended Unit
FXEQ-PVJU
Ceiling-Mounted Cassette (Single Flow)
Ceiling-suspended with slim
and elegant design.
Slim and compact design
for installation flexibility.
For hotel rooms, offices
and residential.
INDOOR UNITS
FXUQ-PVJU
4-Way Blow Ceiling-Suspended Cassette
VRV Product Catalog
45
FXMQ-PBVJU
DC-Ducted Concealed
Ceiling Unit (Medium Static)
Condensate Pump
as Standard
Outside Air
Integration Possible
Powerful, Concealed, Flexible
The ceiling mounted DC-Ducted unit is ideal for small to
large spaces in need of a concealed air-conditioning system.
It is extremely powerful and the compact design allows it
to be completely concealed. This makes it perfect for retail,
classrooms, offices, banks, restaurants, shops and hotels
common areas.
Daikin Zoning Kit, DZK
»» Configurable auxiliary heater control logic
»» Enhanced indoor air quality and LEED ready with
MERV 13 filter options
»» Ease of installation with auto adjusting airflow at
commissioning based on external static pressure
»» Flexible ductwork design with ESP capabilities up
to 0.8" W.G.
»» Installation flexibility with a low profile, compact design
at less than 12" in height
»» Easy maintenance with complete service access
from below
»» Option to permanently turn off the condensate pump
via field settings
BRC1E73
(option)
BRC2A71
(option)
BRC4C82
(option)
Auto Adjust External Static Pressure
»» After installation, it is possible that the actual duct
resistance is lower than expected at the time of designing.
As a consequence, the air-flow will be too high.
»» With the automatic air-flow adjustment function the unit
can adapt its fan speed to a lower curve, so the air-flow
decreases.
»» The air-flow will always be within 10% of the rated air-flow
because of the amount of possible fan curves (more than
8 fan curves available per model).
»» Alternatively the installer can manually select a fan curve
with the wired remote control.
Auto Adjust External Static Pressure
Applications
External static pressure
INDOOR UNITS
Features and Benefits
»» Capacity range up to 54 MBH.
»» Energy efficient due to the DC fan motor
»» Ideal to use together with the optional
»» Offices
»» Hotels
»» Schools
»» Retail
Airflow (cfm)
± 10%
Fan characteristic curve
Actual duct resistance curve
Duct resistance curve at the time of designing
Rated airflow
Airflow without airflow automatic adjustment
Actual airflow
46
www.daikincomfort.com
0.6 Ton
V/ph/Hz
0.75 Ton
1.0 Ton
1.25 Ton
1.5 Ton
2.5 Ton
3.0 Ton
FXMQ07PBVJU FXMQ09PBVJU FXMQ12PBVJU FXMQ15PBVJU FXMQ18PBVJU FXMQ24PBVJU FXMQ30PBVJU FXMQ36PBVJU
208-230/1/60
4.0 Ton
4.5 Ton
FXMQ48PBVJU
FXMQ54PBVJU
BTU/h
7,500
9,500
12,000
15,000
18,000
24,000
30,000
36,000
48,000
54,000
BTU/h
8,500
10,500
13,500
17,000
20,000
27,000
34,000
40,000
54,000
60,000
450/410/388
560/530/500
635/582/529
CFM
in.
in.
in.
317/264/229
21-5/8
27-9/16
1,094/953/812 1,130/953/812
39-3/8
1,377/1,165/988 1,624/1,377/1,130
55-1/8
27-9/16
in.
dB(A)
688/618/565
11-3/16
18-3/8
33/31/29
39/37/35
40/38/37
41/39/37
in. O.D.
42/40/38
43/41/39
44/42/40
46/45/43
1-1/4
in.
in.
1/2 (Flare)
1/4 (Flare)
5/8 (Flare)
3/8 (Flare)
R-410A
Electronic Expansion Valve
A
A
15
0.6
1.4
1.5
1.6
1.8
2.8
2.9
3.4
Fuse and Fan Driver Overload Protector
Galvanized Steel Plate
in. W.G.
0.40/0.12
0.80/0.20
MERV 13 Filter Kit Option contains a MERV 13 filter, adapter frame and easy to follow
installation instructions and can be installed on the following models only:
Kit Model
Indoor Unit
DACA-FXMQ12131K
FXMQ07-09PBVJU
DACA-FXMQ14131K
FXMQ12PBVJU
DACA-FXMQ30131K
FXMQ15-24PBVJU
DACA-FXMQ48131K
FXMQ30-54PBVJU
FXMQ-PBVJU ACCESSORIES
Model Name
FXMQ07PBVJU
Navigation Remote
Controller*
Simplified Wired
Remote Controller*
Wireless Remote
Controller
Remote Sensor Kit
Wiring Adapter PCB
(interface with aux/
primary heater,
humidifier, OA damper/
fan)
Group Control Adapter
PCB (connects to
external BMS)
*
2.0 Ton
INDOOR UNITS
FXMQ-PBVJU
SPECIFICATIONS
Model Name
Power Supply
Rated Cooling
Capacity
Rated Heating
Capacity
Airflow Rate
(H/M/L)
Height
Width
Depth
Condensate Pump
Lift
Sound Pressure
(H/M/L)
Condensate Pipe
Connection
Gas
Pipe
Connections Liquid
Refrigerant
Refrigerant Control
Maximum
Overcurrent
Protective Device
Minimum
Circuit Amps
Protection Devices
External Finish
External Static
Pressure (H/L)
FXMQ09PBVJU
FXMQ12PBVJU
FXMQ15PBVJU
0.56/0.20
ENTHALPY ECONOMIZER (FIELD APPLIED ACCESSORY)
Model
Indoor Unit
ECONMQ12P-8-1K (MERV 8 Filter)
FXMQ07-09PBVJU
ECONMQ12P-13-1K (MERV 13 Filter)
ECONMQ30P-8-1K (MERV 8 Filter)
ECONMQ30P-13-1K (MERV 13 Filter)
FXMQ15-24PBVJU
ECONMQ48P-8-1K (MERV 8 Filter)
ECONMQ48P-13-1K (MERV 13 Filter)
FXMQ30-54PBVJU
FXMQ18PBVJU FXMQ24PBVJU
FXMQ30PBVJU
FXMQ36PBVJU
FXMQ48PBVJU
FXMQ54PBVJU
BRC1E73
BRC2A71
BRC4C82
KRCS01-4B
KRP1C74
KRP4A71
Optional face plates available to provide a more intuitive user interface and disable specific functions
FXMQ-PBVJU INSTALLATION SPACE
Air
Outlet
a = 12" or more if one inspection
hatch (17-3/4" x 17-3/4") on the
control box side and a space of
11-13/16” or more under the unit.
Ceiling
Floor Surface
99" or more
if no ceiling
a
99" or more
if no ceiling
Air
Inlet
a
18" or more
a = 1" or more if an inspection
hatch the size of the indoor unit
plus an additional 12" or more on
the control box side is installed.
Ceiling
Floor Surface
VRV Product Catalog
47
FXMQ-PBVJU (cont.)
DC-Ducted Concealed
Ceiling Unit (Medium Static)
Kits and Accessories
INDOOR UNITS
The optional Daikin Zoning Kit (DZK)
increases the flexibility of the Daikin
VRV and SkyAir systems by adding a
Zoning Box to an indoor unit fan coil (FXMQ–P or FBQ–P series,
respectively) allowing several separate ducts to supply air to
different individually-controlled zones in the building. A zone
can be a room, part of room, or several rooms. This flexible and
scalable Zoning Kit integrates seamlessly with the indoor unit
fan coil controls. The DZK system controls work together with
the regular Daikin zone controller (i.e. BRC1E73) to establish
the required set-point, fan speed and mode of operation that
is then requested to the VRV indoor unit via the Daikin zone
controller. This allows the internal DZK control algorithms to
look at the number of zone dampers in operation, and at what
position the dampers need to be and adjust the VRV indoor
unit operation accordingly. The DZK system is not directly
compatible with the suite of Daikin centralized control options
such as iTM and iTC.
A complete Daikin Zoning Kit consists of Zoning Box (with
Control Board), Wired Thermostat, and Wireless Thermostats.
The optional DZK BACnet Interface enables any BACnet/IP
compatible Building Management System to be used for
remote monitoring and control of the DZK.
NEW
Wired Thermostat
The 3rd generation DZK introduces all new,
redesigned Wired and Wireless thermostats.
The revised form factor offers a slim profile
and capacitive touch capability for an enhanced
user experience.
The wired thermostat in the DZK is a graphical colored, touchscreen interface with text menus, intuitive icons, and guided
scheduling capability. It displays temperatures and operating
values, and selects the operating mode for the system.
NEW
Wireless Thermostats
The optional Wireless thermostat offers a backlit,
low energy E Ink display with capacitive touch
buttons. The user can adjust the zone set point
temperature, set user mode schedules, activate
local ventilation, and more.
The optional Wireless Lite thermostat offers
a sleek, simple user interface to adjust the
local zone set point temperature using led-lit
capacitive touch buttons.
48
www.daikincomfort.com
Now with BACnet®/IP compatibility
Zoning Box with Control Box
(Model Depends on Indoor Unit)
The Zoning Box in the Daikin Zoning
Kit mounts easily on Daikin’s Indoor
Unit FXMQ–P or FBQ-P series fan
coils. It consists of the enclosure,
individually motorized dampers, and a
control box. It is available in different sizes
and damper configurations and by utilizing
ducts for air supply it can be used to control
the air temperature in up to 6 zones. The wired
thermostat and the wireless thermostats provide temperature inputs and user interfaces for programming
and adjustment of the control functions for each zone.
DZK BACnet Interface
If VRV systems are
installed with the DZK
system to accomplish
a variety of zoning
solutions and there is a
requirement to be able
to monitor and control the various DZK zone dampers from
a centralized control system, it is possible to utilize the DZK
BACnet Interface to address this solution.
The DZK BACnet Interface will work with any BACnet/IP compatible Building Management System.
DAIKIN ZONING KIT (DZK) – KIT STRUCTURE AND GENERAL TECHNICAL DATA
Zoning Box with Control Box
DZK Product Number
Compatible with Indoor
Unit Fan Coils
- FXMQ15-24PBVJU
- FBQ18-30PVJU
Compatible with Indoor
Unit Fan Coils
- FXMQ30-54PBVJU
- FBQ36-42PVJU
Number of Zones
Compatibility
Number of Air Duct
Outlets
x Diameter (")
Required Quantity
DZK030E4-3
DZK030E5-3
DZK048E4-3
DZK048E6-3
Kit Structure
Wireless
Thermostat
DZK-ZTS-3-W
Wired
Thermostat
DZK-MTS-3-W
Wireless Lite
Thermostat
DZK-LTS-3-W
Yes
No
Yes
No
Yes
Yes
BACnet ® Interface
DZK-BACNET-3
Maximum 4
Maximum 5
Maximum 4
Maximum 6
-
-
-
-
4 x Ø8
5 x Ø6
4 x Ø8
6 x Ø6
-
-
-
-
One Per Indoor
Unit Fan Coil
One Per Indoor
Unit Fan Coil
One Per Indoor
Unit Fan Coil
One Per Indoor
Unit Fan Coil
Minimum One Per
Indoor Unit Fan Coil
Number Of Zones
Minus Number Of
Wired Thermostats
Number Of Zones
Minus Number Of
Wired Thermostats
One Per DZK Zoning
Box With BACnet/IP
Technical Data
Input Voltage
10.43
43.58
3.62
3.62
0.62
53.46
10.43
20.24
18.04
23.32
110/230 VAC
Full Load Amps (A)
0.25
0.4
12 VDC, from
Zoning Box
0.46
CR2450 Battery
-
1.6
2.7
1.2
0.063
12 VDC, from
Control Board
-
INDOOR UNITS
Height (")
Width (")
Depth (")
Weight (lb.)
-
For configuration of DZK systems without BACnet, either products with, or without, the BACnet functionality can be used, even “mix and match”.
CONTROLS CONNECTION OF FXMQ-PBVJU AND DZK (WITHOUT BACNET)
Typical Zoning Kit Configuration — 4 Zones
Wired Thermostat
Wireless Thermostats
Wireless Lite Thermostat
Zoning Box
Control Box
Zoning Box
Navigation
Remote Controller
Indoor Unit Fan Coil
VRV Product Catalog
49
FXDQ-MVJU
Slim-Duct, Built-In
Concealed Ceiling Unit
Condensate Pump
as Standard
Outside Air
Integration Possible
Filter
Included
Concealed, Slim, Quiet, Comfortable
The slim duct built-in concealed unit is available for use with
the VRV systems to complement the existing concealed
ceiling unit options. With its low profile and low sound level
this unit can be installed into limited ceiling void, bulkhead
or soffit space.
INDOOR UNITS
Features and Benefits
»» Slim height, at only 7-7/8", makes it suitable for most of
the applications where attic / bulkhead space is limited
»» With a sound level down to 29 dB(A) these units are
among the quietest on the market
»» Factory shipped for rear air inlet — field convertible
to bottom air inlet
»» Washable filter included
»» Condensate pump with vertical lift of up to 21-5/8"
included as standard
»» Blends unobtrusively with any interior decor; only the
suction and discharge grills are visible
Applications
»» Hotel rooms
»» Multi-family
residences
»» Single family
residences
»» School dormitories
50
www.daikincomfort.com
BRC1E73
(option)
BRC2A71
(option)
BRC4C82
(option)
FXDQ-MVJU SPECIFICATIONS
Model Name
Power Supply
Rated Cooling Capacity
Rated Heating Capacity
Airflow Rate (H/L)
Weight
Height
Width
Depth
Sound Pressure (H/L)
Condensate Pump Lift
Condensate Pipe Connection
Refrigerant
Refrigerant Control
Maximum Overcurrent Protective Device
9,500
10,500
280/226
51
1.5 TONS
FXDQ18MVJU
2 TONS
FXDQ24MVJU
18,000
20,000
440/350
63
24,000
27,000
580/460
71
35-7/16
43-5/16
35/31
36/32
7-7/8
27-9/16
24-7/16
33/29
21-5/8
1-1/32
1/2 (Flare)
1/4 (Flare)
5/8 (Flare)
3/8 (Flare)
R-410A
Electronic Expansion Valve
15
A
0.9
1.3
1.4
0.17/0.06
0.17/0.06
Fuse and Fan Motor Thermal Protector
Galvanized Steel Plate
Removable, Washable, Mildew Proof
in. W.G.
0.12/0.04
Heating Mode
Indoor: 70 °F DB
Outdoor: 47 °F DB / 43 °F WB
Pipe Length: 25 ft.
Level Difference: 0 ft.
FXDQ07MVJU
FXDQ09MVJU
FXDQ12MVJU
BRC1E73
BRC2A71
BRC4C82
KRCS01-1B
Note: Specifications are subject to change
without notice.
FXDQ18MVJU
FXDQ24MVJU
APFXDQ18
APRFFXDQ18
APRFFXDQ18F
APFXDQ24
APRFFXDQ24
APRFFXDQ24F
INDOOR UNITS
Cooling Mode
Indoor: 80 °F DB / 67 °F WB
Outdoor: 95 °F DB
Pipe Length: 25 ft.
Level Difference: 0 ft.
FXDQ-MVJU ACCESSORIES
Model Name
Navigation Remote Controller*
Simplified Wired Remote Controller*
Wireless Remote Controller
Remote Sensor Kit
Wiring Adapter PCB (interface with aux/primary heater,
humidifier, OA damper/fan)
Group Control Adapter PCB (connects to external BMS)
Access Panel (single door)
Access Panel with return air filter (single door)
Filter Media Replacement
KRP1C75
KRP4A74
APFXDQ070912
APRFFXDQ070912
APRFFXDQ070912F
Optional face plates available to provide a more intuitive user interface and disable specific functions
FXDQ-MVJU INSTALLATION SPACE
Choose an installation site that ensures both optimum air distribution and sufficient clearance for maintenance. The return air inlet can be easily changed from rear to bottom using the same chamber lid.
Protection net
Air inlet
12"
or more
12"
or more
Control Box
Maintenance
Space
Chamber lid
Maintenance
Space
Air discharge
Air discharge
Ceiling
Air inlet
100"or more
13/16" or more
H = 9-1/2"
or more
Protection net
7-7/8"
*
7,500
8,500
1 TON
FXDQ12MVJU
208-230/1/60
12,000
13,500
A
Minimum Circuit Amps
Protection Devices
External Finish
Standard Filter Type
External Static Pressure (H/L)
Nominal Conditions:
0.75 TON
FXDQ09MVJU
V/ph/Hz
BTU/h
BTU/h
CFM
lbs.
in.
in.
in.
dB(A)
in.
in. O.D.
in.
in.
Gas
Liquid
Pipe Connections
0.6 TON
FXDQ07MVJU
Chamber lid
Chamber lid
Air discharge
Protection net
Air discharge
Floor surface
(length : in.)
VRV Product Catalog
Air inlet
51
FXTQ-TAVJUA(D)
Multi-Position
Air Handling Unit
Outside Air
Integration
Possible
AI
All
Aluminum
Coil
Variable
Speed
ECM Motor
Outstanding flexibility and performance
The FXTQ_TAVJUA(D) air handler features full multi-position*
flexibility to meet the most demanding installation conditions.
A multitude of features ensure reliable, efficient performance
year round.
INDOOR UNITS
Features and Benefits
»» Expanded capacity lineup, featuring ten models ranging
from ¾ ton to 5 tons, with a redesigned** unit frame for
maximum durability.
»» Full multi-position air handler capable of upflow, downflow*,
horizontal right, and horizontal left installation.
»» A high efficiency, ECM motor powers the fan to deliver
nominal CFM at up to 0.9" w.g. static. An auto fan speed
setting automatically adjusts the fan speed through 5 steps
based on the load in the space.
»» Wide line up of electric heat (field installed)
options from 3kW to 25kW.
»» An auxiliary heat logic features a reduced heater operation
deadband and the ability to run both heat pump and auxiliary
heat for maximum comfort and performance in colder
climates. The auxiliary heat can be interlocked with the
ambient temperature sensed by the outdoor unit.
»» Designed with less than 2% air leakage when tested in
accordance with ASHRAE standard 193.
»» New integrated control board reduces** the number of
electrical connections required. Quick disconnect control
wiring terminals simplify installation.
»» Easily integrate with third party accessories such as
a humidifier or economizer with on-board contacts.
Applications
»» Multi-family
»» Single-family
»» Hotels
»» Offices
»» Up to 200% connection ratio is possible on applicable
VRV IV systems.
»» Available with optional factory installed disconnect
(Built to order — model FXTQ_TAVJUD.
*Downflow requires field installed optional downflow accessory.
(Part number DFK-B/C/D)
**Compared to previous model FXTQ_P
Designed for Compact Spaces
With its compact and space saving design, the new
FXTQ_TAVJUA(D) air handler units are engineered to suit
most light commercial and residential applications.
»» At under 46" tall and only 17-1/2” wide
up to 3 tons, the FXTQ_TAVJUA(D) can
be installed in tight closet spaces.
»» Designed for zero clearance on three sides and
only 24" clearance on the front for service.
»» Sound levels as low as 36 dBA to suit
applications in sound sensitive environments.
Electric Heater Options
ELECTRICAL HEATER CAPACITY
Model Name
FXTQ09TAVJUA(D)
FXTQ12TAVJUA(D)
FXTQ18TAVJUA(D)
FXTQ24TAVJUA(D)
FXTQ30TAVJUA(D)
FXTQ36TAVJUA(D)
FXTQ42TAVJUA(D)
FXTQ48TAVJUA(D)
FXTQ54TAVJUA(D)
FXTQ60TAVJUA(D)
52
www.daikincomfort.com
3kW 5kW 6kW 8kW 10kW 15kW 19kW 20kW 25kW
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
SPECIFICATIONS
Model Name
Model Name (With factory disconnect)
Power Supply
Nominal Cooling Capacity*1
Nominal Heating Capacity*2
Type
Motor Output
Air Flow Rate (H/M/L
Fan
Static Pressure*3
Drive Type
Height
Width
Depth
Weight (net) (TAVJUA/TAVJUD)
Sound Pressure Level (H speed)
Liquid
Pipe
Gas
Connections
Condensate Drain
Refrigerant Control
Maximum Overcurrent
Protective Device
Minimum Circuit Amps
V/ph/Hz
Btu/h
Btu/h
HP
CFM
in w.g.
in.
in.
in.
lbs.
dB(A)
in.
in.
in.
1 TON
FXTQ12TAVJUA
FXTQ12TAVJUD
9,500
10,500
300 / 275 / 250
105/108
36
1.5 TON
FXTQ18TAVJUA
FXTQ18TAVJUD
208/230VAC, 60Hz, 1 phase
12,000
18,000
13,500
20,000
Sirocco FC Centrifugal
1/2
400 / 340 / 280
600 / 510 / 420
0.18” / 0.9”
Variable speed ECM
45
17.5
21
112/115
111/118
45
1/4 (Braze)
1/2 (Braze)
3/4 (fpt)
Electronic Expansion Valve
A
15
A
4.9
V/ph/Hz
Btu/h
Btu/h
3 TON
FXTQ36TAVJUA
FXTQ36TAVJUD
3.5 TON
FXTQ42TAVJUA
FXTQ42TAVJUD
36,000
40,000
42,000
46,000
4 TON
FXTQ48TAVJUA
FXTQ48TAVJUD
208/230VAC, 60Hz, 1 phase
48,000
54,000
Sirocco FC Centrifugal
3/4
1520 / 1290 /1060
HP
CFM
in w.g.
1/2
1050 / 900 / 750
in.
in.
in.
lbs.
dB(A)
in.
in.
in.
45
17.5
53.43
21
113/116
52
144/147
54
1400 / 1190 / 980
0.23” / 0.9”
2 TON
FXTQ24TAVJUA
FXTQ24TAVJUD
2.5 TON
FXTQ30TAVJUA
FXTQ30TAVJUD
24,000
27000
30,000
34,000
800 / 680 / 560
1000 / 850 / 700
0.23” / 0.9”
112/115
113/116
52
3/8 (Braze)
5/8 (Braze)
4.5 TON
FXTQ54TAVJUA
FXTQ54TAVJUD
5 TON
FXTQ60TAVJUA
FXTQ60TAVJUD
54,000
60,000
60,000
66,000
INDOOR UNITS
SPECIFICATIONS
Model Name
Model Name (With factory disconnect)
Power Supply
Nominal Cooling Capacity*1
Nominal Heating Capacity*2
Type
Motor Output
Air Flow Rate (H/M/L
Fan
Static Pressure*3
Drive Type
Height
Width
Depth
Weight (net) (TAVJUA/TAVJUD)
Sound Pressure Level (H speed)
Liquid
Pipe
Gas
Connections
Condensate Drain
Refrigerant Control
Maximum Overcurrent
Protective Device
Minimum Circuit Amps
0.75 TON
FXTQ09TAVJUA
FXTQ09TAVJUD
1.0
1800 / 1530 / 1260
1800 / 1530 / 120
0.28” / 0.9”
Variable speed ECM
21
165/168
50
3/8 (Braze)
5/8 (Braze)
3/4 (fpt)
Electronic Expansion Valve
A
A
58
24.5
15
4.9
6.5
8.6
Nominal cooling capacities are based on the following conditions: 80 °FDB / 67 °FWB (26.7 °CDB / 19.4 °CWB) return air temperature;
95 °FDB (35 °CDB) outdoor temperature; 25 ft. (7.6 m) equivalent refrigerant piping.
*2
Nominal heating capacities are based on the following conditions: 70 °FDB (21.1 °CDB) return air temperature;
47 °FDB / 43 °FWB (8.3 °CDB / 6.1 °CWB) outdoor temperature; 25 ft. (7.6 m) equivalent refrigerant piping.
*3
External static pressures are indicated as rated / maximum allowable range.
*1
VRV Product Catalog
53
FXMQ-MVJU
Concealed
Ceiling Unit (Medium Static)
Outside Air
Integration Possible
Concealed, Slim Design, Strong, Comfortable
The FXMQ-MVJU ducted fan coil unit is ideal for
larger open space floor plans usually found in offices,
retails, hotels, or education facilities. It performs
well across multiple spaces that can benefit from
the same mode of operation, limiting equipment and
installation cost.
INDOOR UNITS
Features and Benefits
»» Design flexibility with a capacity range up to 96 MBH
»» Improved ductwork and filtration flexibility with ESP
capabilities of up to 1.1" W.G.
»» Low profile design of less than 19" high to reduce
required installation space
Applications
»» Hotel/conference
centers
»» Schools
»» Retail/shopping
centers
»» Large open-plan
offices
»» Churches
54
www.daikincomfort.com
BRC1E73
(option)
BRC2A71
(option)
BRC4C82
(option)
FXMQ-MVJU SPECIFICATIONS
Model Name
Power Supply
Rated Cooling Capacity
Rated Heating Capacity
Airflow Rate (H/L)
Weight
Height
Width
Depth
Sound Pressure (H/L)
Condensate Pipe Connection
Pipe Connections
6 TON
FXMQ72MVJU
V/ph/Hz
BTU/h
BTU/h
CFM
lbs.
in.
in.
in.
dB(A)
in. O.D.
in.
in.
Gas
Liquid
Refrigerant
Refrigerant Control
Maximum Overcurrent Protective Device
Minimum Circuit Amps
Protection Devices
External Finish
External Static Pressure (Nominal/Maximum)
Nominal Conditions:
208-230/1/60
72,000
81,000
2,047/1,764
96,000
108,000
2,541/2,188
380
18-1/8
54-3/8
43-5/16
48/45
1
3/4 (Flare)
7/8 (Flare)
3/8 (Flare)
R-410A
Electronic Expansion Valve
15
A
A
9.5
10.7
Fuse and Fan Motor Thermal Protector
Galvanized Steel Plate
in. W.G.
0.38/0.95
0.43/1.1
Heating Mode
Indoor: 70 °F DB
Outdoor: 47 °F DB / 43 °F WB
Pipe Length: 25 ft.
Level Difference: 0 ft.
Note: Specifications are subject to change
without notice.
FXMQ72MVJU
INDOOR UNITS
Cooling Mode
Indoor: 80 °F DB / 67 °F WB
Outdoor: 95 °F DB
Pipe Length: 25 ft.
Level Difference: 0 ft.
FXMQ-MVJU ACCESSORIES
Model Name
Navigation Remote Controller*
Simplified Wired Remote Controller*
Wireless Remote Controller
Remote Sensor Kit
Wiring Adapter PCB (interface with aux/primary heater, humidifier, OA damper/fan)
Group Control Adapter PCB (connects to external BMS)
High Efficiency Filter Kit (MERV 13)
High Efficiency Filter Kit (MERV 8)
FXMQ96MVJU
BRC1E73
BRC2A71
BRC4C82
KRCS01-1B
KRP1C74
KRP4A71
DACA-MQ96M-13-1K
DACA-MQ96M-8-1K
Optional face plates available to provide a more intuitive user interface and disable specific functions
FXMQ-MVJU INSTALLATION SPACE
a = 12" or more if one inspection
hatch (17-3/4" x 17-3/4") on the
control box side and a space of
11 13/16" or more under the unit.
a
Ceiling
Floor Surface
99" or more
if no ceiling
Air
Inlet
Air
Outlet
99" or more
if no ceiling
*
8 TON
FXMQ96MVJU
a
18" or more
a = 1" or more if an inspection
hatch the size of the indoor unit
plus an additional 12" or more on
the control box side is installed.
Ceiling
Floor Surface
VRV Product Catalog
55
FXNQ-MVJU9
Concealed
Floor-Standing Unit
Outside Air
Integration Possible
Filter
Included
Versatile, Logical, Durable, Quiet
The ideal way to save space, our floor-standing units can
easily be installed along a perimeter wall — or concealed.
The air distribution from these models will allow you to find
the right balance for classrooms, churches, office hallways or
similar spaces. The concealed floor units cover a wide range
of capacities and can be built into counter in order to maintain
the aesthetics of the room.
INDOOR UNITS
Features and Benefits
»» Ideal for installation beneath a window
»» Unit requires minimal installation space
»» Fitted with a washable long-life filter
»» Remote-control options available
»» Space-saving unit can be freestanding or
wall-mounted, concealed or exposed
»» Models range from 7.5 MBH to 24 MBH
Applications
»» Multi-family
residences
»» Single-family
residences
»» Churches
»» Historic buildings
»» Schools
»» Offices
56
www.daikincomfort.com
BRC1E73
(option)
BRC2A71
(option)
BRC4C82
(option)
FXNQ-MVJU9 SPECIFICATIONS
Model Name
Power Supply
0.6 TON
FXNQ07MVJU9
0.75 TON
FXNQ09MVJU9
1 TON
FXNQ12MVJU9
V/ph/Hz
2 TON
FXNQ24MVJU9
24,000
208-230/1/60
Rated Cooling Capacity
BTU/h
7,500
9,500
12,000
18,000
Rated Heating Capacity
BTU/h
8,500
10,500
13,500
20,000
27,000
280/210
490/380
560/420
Airflow Rate (H/L)
CFM
245/210
Weight
lbs.
47
Height
in.
Width
in.
Depth
in.
36-5/8
60
42-1/8
53-1/8
8-5/8
dB(A)
Condensate Pipe Connection
in. O.D.
in.
in.
Gas
Liquid
56
24
Sound Pressure (H/L)
Pipe Connections
35/32
36/33
40/35
41/36
27/32
1/2
1/4
5/8
3/8
Refrigerant
R-410A
Refrigerant Control
Maximum Overcurrent
Protective Device
Minimum Circuit Amps
Protection Devices
External Finish
Standard Filter Type
Electronic Expansion Valve
A
15
A
0.3
0.5
Fuse and Fan Motor Thermal Protector
Galvanized Steel Plate
Resin Net (with Mold Resistant)
Cooling Mode
Indoor: 80 °F DB / 67 °F WB
Outdoor: 95 °F DB
Pipe Length: 25 ft.
Level Difference: 0 ft.
Heating Mode
Indoor: 70 °F DB
Outdoor: 47 °F DB / 43 °F WB
Pipe Length: 25 ft.
Level Difference: 0 ft.
FXNQ-MVJU9 ACCESSORIES
Model Name
Navigation Remote Controller
Simplified Wired Remote Controller*
Wireless Remote Controller
Remote Sensor Kit
Wiring Adapter PCB (interface with aux/primary heater, humidifier, OA damper/fan)
Group Control Adapter PCB (connects to external BMS)
Condensate Pump
FXNQ07MVJU9
0.6
INDOOR UNITS
Nominal Conditions:
Note: Specifications are subject to change
without notice.
FXNQ09MVJU9
FXNQ12MVJU9
BRC1E73
BRC2A71
BRC4C82
KRCS01-1B
KRP1C74
KRP4A71
DACA-CP3-1
FXNQ18MVJU9
FXNQ24MVJU9
Optional face plates available to provide a more intuitive user interface and disable specific functions
FXNQ-MVJU9 INSTALLATION SPACE
6" or more
70" or more
Air inlet
direction
24-5/8"
Front
side
Air flow
direction
Maintenance
area
Base
IMPORTANT
Leave sufficient clearance for air inlet and maintenance.
MODEL
FXNQ12MVJU9
FXNQ18 - 24MVJU9
FXNQ07-09MVJU
A (IN.)
28
39
23
B (IN.)
46
57
41
VRV Product Catalog
3-1/8" or more
40" or more
3/4" or
more
*
1.5 TON
FXNQ18MVJU9
Ao
r
B o mor
rm e
ore
57
FXFQ-TVJU
Round Flow
Sensing Cassette
Condensate Pump
as Standard
Optional
Auto Cleaning Filter
Outside Air
Integration Possible
Surface & Occupancy
Sensor Kit as Standard
Filter
Included
Adaptive Comfort Control
INDOOR UNITS
The Round Flow Sensing Cassette is ideal for open plan
applications such as classrooms and offices where adaptive
comfort control is preferred. The unit provides an excellent
comfort level, energy efficiency, and flexibility due to advanced
control functions based on input from three room sensors
(occupancy, air temperature, and surface temperature). With
18 configurable airflow distribution patterns, it can be efficient
and provide a comfortable environment in smaller, more
intricate spaces as well.
Features and Benefits
»» Capacity range from 7.5 to 48 MBH.
»» True 360° Airflow and three room sensors enables
optimized occupant comfort and efficiency
BRC1E73
(option)
»» Energy efficient with DC fan motor and auto-logic that
adjusts fan speed based on space load
»» Optional self-cleaning air filter panel to further increase
efficiency and reduce maintenance costs, when used in
VRV IV systems
»» Very flexible with 18 different possible airflow patterns,
ensuring ideal air distribution to maximize comfort
and efficiency
»» Compact design to allow for installation in small ceiling voids
»» Sound pressure levels as low as 27 db(A)
»» Enhanced indoor air quality and LEED ready with
MERV 13 filter options
The built-in occupancy sensor has two main functions: save
energy and optimize occupancy comfort. In order to save
energy, the function of the occupancy sensor can be used
to automatically set back the air temperature and also lower
the fan speed if no people are present in the room.
BRC2A71
(option)
Together with the occupancy sensor, the air-temperature
sensor and the built-in surface temperature sensor are used
to maintain an even and comfortable temperature distribution
from floor to ceiling in the room. This is done by automatically
adjusting the supplied airflow rate and the individual position of
each of the four supply air louvers in the unit, thus maintaining
the required comfortable space environment.
In order to further increase efficiency and reduce maintenance
costs, the Round-Flow Sensing Cassette can be equipped
with an optional self-cleaning filter panel that performs
automatic air-filter cleaning up to once a day. Dust is deposited
into a collection box during the self-cleaning process. When
indicated with light on the unit and on the controller display,
the dust collection box in the unit can easily and quickly be
emptied with a standard vacuum cleaner.
4-way flow vs. Round Flow
Applications
»» Retail
»» Schools
»» Offices
»» Restaurants
Round Flow Ceiling Mounted Cassette type offers 360˚ airflow with
improved temperature distribution.
4-way flow
Areas of uneven
temperature
58
www.daikincomfort.com
Round Flow
Much fewer
areas of uneven
temperature
Advanced design for comfort and efficiency
DC Fan Motor
Heat Exchanger Design
Very efficient — enables fan auto
logic based on ∆T set point
Optimized for part load operation
— great enhancement to seasonal
energy efficiency
DC Drain Pump
Occupancy and Surface
Temperature Sensors
Low power consumption
»» Efficient due to large air
discharge outlets
Optional Self-Cleaning
Filter Panel
»» Unique 360° airflow
Provides optimum efficiency, airflow
and reduced maintenance
»» 4 individually controlled
distribution
louvers enables optimized
comfort in the space
»» Possibility to close 1, 2 or 3
louvers adds flexibility
Automatic air-direction control
Dual infrared sensors
Sensors detect the presence of people and surface temperature to provide
comfortable air-conditioning and energy savings.
Infrared presence sensor
The sensor detects human presence, and energy saving control
can be performed when no people are detected.
Infrared surface sensor
The sensor detects the surface temperature and automatically adjusts operation
of the indoor unit to reduce the temperature difference between the ceiling and
the floor.
Air flow from the indoor unit is automatically adjusted to always maintain
a comfortable environment — even when occupancy changes.
VRV Product Catalog
59
INDOOR UNITS
Decoration Panel
Enables additional energy
savings and increased comfort
FXFQ-TVJU (cont.)
Round Flow
Sensing Cassette
Automatic air filter cleaning (optional)
Air filter
INDOOR UNITS
Air filter
brush
At the programmed time, the air filter rotates while the air filter
brush turns back and forth to brush the filter.
Dust from the air filter brush is deposited into the dust collection
container during the fully automatic self-cleaning process.
When indicated, the dust container in the unit is easily emptied
with a standard vacuum cleaner.
60
www.daikincomfort.com
Condensate Pump
as Standard
Optional
Auto Cleaning Filter
Outside Air
Integration Possible
Surface & Occupancy
Sensor Kit as Standard
Filter
Included
0.60 TON
FXFQ07TVJU
0.75 TON
FXFQ09TVJU
1 TON
FXFQ12TVJU
1.25 TON
FXFQ15TVJU
7,500
8,500
420/406/353
9,500
10,500
441/406/353
48
12,000
13,500
441/406/353
15,000
17,000
512/459/388
1.5 TON
FXFQ18TVJU
208-230/1/60
18,000
20,000
742/618/477
48
2 TON
FXFQ24TVJU
2.5 TON
FXFQ30TVJU
3 TON
FXFQ36TVJU
4 TON
FXFQ48TVJU
24,000
27,000
777/618/477
30,000
34,000
1,112/918/671
36,000
40,000
1,165/918/671
58
11-5/16
48,000
54,000
1,218/971/742
36/32/28
43.5/38/32
44/38/32
45/40/35
9-11/16
30/28.5/27
31/29/27
33-1/16
33-1/16
35.5/32/28
33-1/2
1-1/4
1/2 (Flare)
1/4 (Flare)
5/8 (Flare)
3/8 (Flare)
R-410A
Electronic Expansion Valve
15
0.3
Nominal Conditions:
0.4
0.6
0.7
Fuse/Breaker and Fan Motor Thermal Protector
Galvanized Steel Plate
Mold-Resistant Resin Net
Cooling Mode
Indoor: 80 °F DB / 67 °F WB
Outdoor: 95 °F DB
Pipe Length: 25 ft.
Level Difference: 0 ft.
OPTION
Type of panel
Self-Cleaning Filter Panel
Connection pipe (for dust recovery)
L-shape extension pipe
Standard Sensing Decoration Panel
Sealing material for air discharge outlet
Panel spacer
Without T shape pipe
Fresh air
Chamber type
intake kit
With T shape pipe
Replacement long life filter
Self-Cleaning Filter Panel replacement filter
MERV 13 Filter Kit
1.3
Heating Mode
Indoor: 70 °F DB
Outdoor: 47 °F DB / 43 °F WB
Pipe Length: 25 ft.
Level Difference: 0 ft.
FXFQ09-48TVJU
Self-Cleaning Filter Panel
Standard Sensing Decoration Panel
BYCQ125BGW1
KKHAP55B160
KKHAP55A160
BYCQ125B-W1
KDBH55K160F
KDBHQ55B140
KDBP55H160FA
KDBP55H160FA
KDDQ55B140
KDDP55B160K
KAFP55B160
KAFP554A160
DACA-FQP13-1K
1.5
1.8
Note: Specifications are subject to change
without notice.
OUTDOOR / CONDENSING UNIT COMPATIBILITY
FXFQ-TVJU with:
Outdoor
Self-Cleaning
Standard Sensing
Condensing Unit
Decoration Panel
Filter Panel
(BYCQ125BGW1)
(BYCQ125B-W1)
VRV IV-S
Yes
VRV IV
VRV IV W-Series
VRV III
No
Yes
SkyAir
No
INDOOR UNITS
FXFQ-TVJU INSTALLATION SPACE
Indoor
Indoor unit
unit
60" or
more from
a wall
At least 60" from any fixture
charge
FXFQ-TVJU SPECIFICATIONS
Model Name
(V/ph/Hz)
Power Supply
Rated Cooling Capacity
BTU/h
Rated Heating Capacity
BTU/h
Airflow Rate (H/M/L)
CFM
Weight
lbs.
Height
in.
Width
in.
Depth
in.
Sound Pressure (H/M/L)
dB(A)
Condensate Pump Lift
in.
Condensate Pipe Connection
in. O.D.
Gas
in.
Pipe
Connections
Liquid
in.
Refrigerant
Refrigerant Control
Maximum Overcurrent
A
Protective Device
Minimum Circuit Amps
A
Protection Devices
External Finish
Standard Filter Type
Obstacles
Lighting
Exhaust
Exhaust
fan
fan
Indoor
Indoor unit
unit
60
more
aw
(A)
60" or more
80" or more
160" or more
Discharge Suction
Discharge
At least 70"
from a floor
MODEL NAME
(FXFQ-TVJU)
07 · 09 · 12 · 15 · 18 · 24
30 · 36 · 48
A (IN.)
BYCQ125B-W1 BYCQ125BGW1
10
13-1/4
11-3/4
14-7/8
VRV Product Catalog
Floor level
61
FXUQ-PVJU
4-Way Ceiling-Suspended
Cassette
Condensate Pump
as Standard
Filter
Included
Optional Surface &
Occupancy Sensor Kit
Slim, Stylish, Flexible
The unique 4-way ceiling-suspended cassette is an ideal
solution for rooms without a false ceiling, or minimal space
above a false ceiling, where adaptive comfort control
is preferred.
INDOOR UNITS
The optional Sensor Kit (occupancy and surface temperature)
together with air temperature sensor and advanced control
functions enables the unit to provide an exceptional comfort
level, energy efficiency, and flexibility.
Features and Benefits
»» Very low unit height of under 8" makes it an ideal solution
for school, shops, restaurants and offices with no or low
false ceilings
BRC1E73
(option)
BRC2A71
(option)
»» Optional Sensor Kit enables input from three room sensors
to provide optimized occupant comfort and efficiency
»» Stylish unit blends easily with any interior, as the air louvers
close entirely when not in operation
»» Energy efficient fan motor
»» Individual air louver control — one or more louvers can
be easily closed via the remote controller when required
»» Ideal for both new and existing buildings
»» Can also be mounted partially recessed in a false ceiling
»» Same appearance and size for all capacity models
»» Standard drain pump with 19.5" lift
Flexible Airflow Pattern
The four individually controlled air louvers
in the unit enables comfortable space
environment in a variety of
different room layouts.
Air from each louver can be
set to exhaust in 5 different
angles between 0 and 60 degrees,
or set to auto-swing.
Airflow Angles
Applications
»» Retail
»» Schools
»» Offices
»» Restaurants
Auto Swing: Wide discharge angle: 0° to 60°
0°
0°
60°
60°
Fixed angles: 5 levels
0°
0°
60°
62
www.daikincomfort.com
60°
FXUQ-PVJU SPECIFICATIONS
Model Name
Power Supply
Rated Cooling Capacity
Rated Heating Capacity
Airflow Rate (H/M/L)
Weight
Height
Width
Depth
Sound Pressure (H/M/L)
Condensate Pump Lift
Condensate Pipe Connection
Gas
Pipe
Connections
Liquid
Refrigerant
Refrigerant Control
Maximum Overcurrent Protective Device
Minimum Circuit Amps
Protection Devices
External Finish
Standard Filter Type
(V/ph/Hz)
BTU/h
BTU/h
CFM
lbs.
in.
in.
in.
dB(A)
in.
in. O.D.
in.
in.
Nominal Conditions:
1.5 TON
FXUQ18PVJU
2 TON
FXUQ24PVJU
18,000
20,000
24,000
27,000
2.5 TON
FXUQ30PVJU
3 TON
FXUQ36PVJU
30,000
34,000
36,000
40,000
208-230/1/60
795/689/565
58
1095/918/742
60
7-13/16
37 3/8
37 3/8
40/38/36
47/44/40
19.5
VP20
1/2 (Flare)
1/4 (Flare)
5/8 (Flare)
3/8 (Flare)
5/8 (Flare)
3/8 (Flare)
R-410A
Electronic Expansion Valve
15
A
A
0.6
1.4
Fuse and Fan Motor Thermal Protector
White Casing
Resin Net (with Mold Resister)
FXUQ-PVJU ACCESSORIES
Model Name
Sealing Member of Air Discharge Outlet
Decoration Panel for Air Discharge
Replacement Long-Life Filter
Remote Control (wired type)
Sensor Kit 2
Group Control Adapter Printed Circuit Board1
Installation Box for Adapter PCB
Remote Sensor 2
Heating Mode
Indoor: 70 °F DB
Outdoor: 47 °F DB / 43 °F WB
Pipe Length: 25 ft.
Level Difference: 0 ft.
FXUQ18PVJU
Note: Specifications are subject to change
without notice.
FXUQ24PVJU
FXUQ30PVJU
INDOOR UNITS
Cooling Mode
Indoor: 80 °F DB / 67 °F WB
Outdoor: 95 °F DB
Pipe Length: 25 ft.
Level Difference: 0 ft.
FXUQ36PVJU
KDBHP49B140
KDBTP49B140
KAFP551K160
BRC1E73
BRE49B1F
KRP4A74
KRP1BA97
KRCS01-48
¹ Installation box for Adapter PCB (KRP1BA97) is necessary. ² Remote Sensor can only be installed when Sensor Kit is not installed.
FXUQ-PVJU INSTALLATION SPACE
2-1/4"
7-13/16"
13/16"
100" or more
(Required space)
Automatic air-direction control
Air-flow from the indoor unit is automatically adjusted to always maintain a comfortable environment — even when occupancy changes.
VRV Product Catalog
63
FXZQ-MVJU9
2'x2' 4-Way
Ceiling-Mounted Cassette
Condensate Pump
as Standard
Outside Air
Integration Possible
Filter
Included
Elegant, Low-maintenance, Comfortable
The 2'x 2' 4-way Cassette is ideal for open plan applications
such as classrooms, offices and retail. It provides both low
noise and customizable comfort. Air can be distributed in any
of four directions and the 2'x 2' size of the unit makes layout
and installation very easy.
INDOOR UNITS
Features and Benefits
»» Fits in a standard 2'x2' ceiling grid.
»» Sound pressure levels are as low as 29 dB(A)
»» Space-saving depth of units requires only 11.6"
of ceiling space
»» Three auto-swing positions to choose from — standard,
draft prevention and ceiling stain prevention
»» Simple installation with an easy-to-fit decoration panel,
easy height adjustment and a suction grille that can
rotate up to 90°
»» Easy-to-clean grille, washable long-life filter
»» Condensate pump inside the unit with up to 21-½"
lift as standard
»» Models range from 7.5 MBH to 18 MBH
Applications
»» Retail
»» Schools
»» Offices
BRC1E73
(option)
BRC2A71
(option)
BRC7E830
(option)
Flexible Airflow Patterns
The four air louvers in
the unit enables
comfortable space
environment in many
different room layouts.
Airflow Angles
Auto Swing: Wide discharge angle: 0° to 60°
0°
0°
60°
60°
Fixed Angles: 5 Levels
0°
0°
60°
60°
Angles can be also set on site to prevent drafts (0°-35°) or soiling
of the ceiling (25°-60°), other than standard setting (0°-60°).
64
www.daikincomfort.com
4-Way Flow
3-Way Flow
L-Shaped
2-Way Flow
FXZQ-MVJU9 SPECIFICATIONS
Model Name
Power Supply
Rated Cooling Capacity
Rated Heating Capacity
Airflow Rate (H/L)
Weight
Height
Width
Depth
Height
Decoration Panel
Width
Length
Sound Pressure (H/L)
Condensate Pump Lift
Condensate Pipe Connection
Gas
Pipe Connections
Liquid
Refrigerant
Refrigerant Control
Maximum Overcurrent Protective Device
0.6 TON
FXZQ07M7VJU9
0.75 TON
FXZQ09M7VJU9
7,500
8,700
320/247
9,500
11,100
320/347
31/29
33/29
V/ph/Hz
BTU/h
BTU/h
CFM
lbs.
in.
in.
in.
in.
in.
in.
dB(A)
in.
in. O.D.
in.
in.
A
15,000
17,500
388/282
18,000
21,000
495/353
41/34
0.8
Fuse and Fan Motor Thermal Protector
Galvanized Steel Plate
Resin Net (with Mold Resistant)
Cooling Mode
Indoor: 80 °F DB / 67 °F WB
Outdoor: 95 °F DB
Pipe Length: 25 ft.
Level Difference: 0 ft.
Heating Mode
Indoor: 70 °F DB
Outdoor: 47 °F DB / 43 °F WB
Pipe Length: 25 ft.
Level Difference: 0 ft.
FXZQ-MVJU9 ACCESSORIES
Model Name
Navigation Remote Controller*
Simplified Wired Remote Controller*
Remote Sensor Kit
Decoration Panel
Wiring Adapter PCB (interface with aux/primary heater, humidifier, OA damper/fan)
Long-Life Replacement Filter
Sealing Member of Air Discharge Outlet
Panel Spacer
Fresh Air Intake Kit
FXZQ07MVJU9
0.9
Note: Specifications are subject to change
without notice.
FXZQ09MVJU9
FXZQ12MVJU9
BRC1E73
BRC2A71
KRCS01-1B
BYFQ60BU
KRP1B72
KAFQ441BA60
KDBHQ44B60
KDBQ44B60
KDDQ44XA60
FXZQ18MVJU9
Optional face plates available to provide a more intuitive user interface and disable specific functions
FXZQ-MVJU9 INSTALLATION SPACE
H
*59" or
more
Air
discharge
59" or more
*
1.5 TON
FXZQ18M7VJU9
INDOOR UNITS
Nominal Conditions:
1.25 TON
FXZQ15M7VJU9
21-1/2
1-1/32
1/2 (Flare)
1/4 (Flare)
R-410A
Electronic Expansion Valve
15
A
Minimum Circuit Amps
Protection Devices
External Finish
Standard Filter Type
1 TON
FXZQ12M7VJU9
208-230/1/60
12,000
14,000
335/265
42
11-1/4
22-5/8
22-5/8
2-1/4
27-5/8
27-5/8
MODEL
FXZQ07-18MVJU9
Air
Air
inlet discharge
*59" or
more
HEIGHT
11.6" or more
*Leave 7-7/8" or more space on sides
where the air outlet is closed.
VRV Product Catalog
65
FXEQ-PVJU
Ceiling-Mounted Cassette
(Single Flow)
Condensate Pump
as Standard
Outside Air
Integration Possible
Filter
Included
Slim and Compact Design for Installation Flexibility
Features and Benefits
INDOOR UNITS
»» The main body of the
unit is optimized to be
7-7∕ 8 "
a compact design.
Only 7-7⁄8" in height
and a width of 18-½"
making it possible to
use this style of indoor unit in the tightest of spaces.
»» The innovative discharge air louver design forces air in
heating mode to ground level to improve the overall
space heating effect of the indoor unit.
Front view
Overview of the vertical fins
to the right or left up to 45˚
Side view
Balance of horizontal fins to
frequent between 20˚ and 70˚
»» The unit is equipped with both horizontal and vertical
louvers that can be freely adjusted with the remote
controller providing a capability to optimize the airflow
and throw to suit your room design.
»» A Ventilation Air knock-out is provided to allow up
to 15% of the rated airflow through the unit to be
pretreated outside air.
»» The innovative “smooth finish” decoration panel design
helps to minimize dust and dirt build-up and facilitates
easier cleaning.
»» The Indoor Unit
is equipped with
a factory installed
condensate pump with
a lift capacity of up to
33-7/16" (measured
from the bottom of
the unit).
»» The utilization of both a DC-style Fan Motor and
integrated Condensate Pump allow for improvements
in energy consumption as well as lower operating
sound levels than other styles of indoor units.
31-½"
»» The units are equipped
with customizable
auxiliary heat control
settings to facilitate the
On/Off control of an external auxiliary heat solution.
»» This Indoor unit can be set to 5 predetermined fan speeds
using the BRC1E73 wired remote controller, which allows
for optimum and comfortable airflow.
»» For ease of service and maintenance activities,
it is possible to access the main components
of the unit by only removing the decoration panel.
Applications
»» Hotel Rooms
»» Offices
»» Residential
(Apartments,
Condominiums,
etc.)
66
www.daikincomfort.com
FXEQ-PVJU SPECIFICATIONS
Model
Power Supply
Cooling
*1,*3
capacity
Heating
*2,*3
capacity
Min. circuit amps (MCA)
Electrical
Max. overcurrent protection
(MOP)
Casing/color
Dimensions: (H x W x D)
Type
Cooling
Air flow rate
Fan
(Dry coiI) (H/HM/M/ML/L)
0.6 TON
FXEQ07PVJU
0.75 TON
FXEQ09PVJU
1.0 TON
1.25 TON
FXEQ12PVJU
FXEQ15PVJU
1 phase 60Hz 208/230V
1.5 TON
FXEQ18PVJU
2 TON
FXEQ24PVJU
Btu/h
7500
9500
12000
15000
18000
24000
Btu/h
8500
10500
13500
17000
20000
27000
A
0.3
A
15
0.4
0.4
0.5
0.5
0.7
15
15
15
15
15
Galvanized steel plate
in.
7-7∕ 8 x 18-½ x 33-1-1/16
CFM
212/191/173/155/141 244/226/205/187/170 283/265/247/223/194 346/311/276/247/219
Drive
Sound pressure level
Cooling
(H/HM/M/ML/L)
Weight
Piping
connections
dBA
30/29/28/27/26
32/31/30/29/28
35/34/33/32/30
38/37/35/33/31
38
530/481/431/389/346
38/37/35/33/31
40
Liquid
in.
ø ¼ (flare connection)
Gas
in.
ø ½ (flare connection)
Drain
in.
in.
43/41/39/37/35
51
ø 3 ∕8
(fIare connection)
ø 5 ∕8
(flare connection)
PVC26 (0.D. 1-1/32 x I.D. 13/16
25
Electronic expansion valve
R-410A VRV Series
BYEP40AW1
INDOOR UNITS
Model
Color
Dimensions (H x W x D)
Air filter
Weight
441/403/367/336/307
Direct drive
lbs.
Drain pump lift
Refrigerant control
Connectable outdoor unit
Decoration
paneI
(required
option)
7-7∕ 8 x 18-½ x 48-13/16
Sirocco fan
BYEP63AW1
Fresh White
in.
3-3/16 x 21- 5 ∕ 8 x 37-13/32
Resin net (with mold resistant)
17.6
Ibs.
3-3/16 x 21- 5 ∕ 8 x 53-5/32
22
Note: * 1. Nominal cooling capacities are based on the following conditions: return air temperature: 80.0˚ FDB (26.7˚C DB), 67.0˚ FWB (19.4˚CWB), outdoor temperature: 95.0˚ FDB (35.˚C DB)
equivalent ref. piping: 25ft. (7.6m) (Horizontal)
2.Nominal heating capacities are based on the following conditions: return air temperature: 70.0˚ FDB (21.1˚C DB), outdoor temperature: 47.0˚ FDB (8.3˚C DB), 43.0˚ FDB (6.1˚C WB)
equivalent ref. piping: 25ft. (7.6m) (Horizontal)
*
3 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
*
FXEQ-PVJU ACCESSORIES
Model
Name of Option
Decoration panel
Wired remote controller
Simplified remote controller
Remote sensor
Wiring adaptor printed circuit board
Group control adaptor printed circuit board
Adaptor mounting box
FXEQ07PVJU
FXEQ09PVJU
FXEQ12PVJU
FXEQ15PVJU
FXEQ18PVJU
FXEQ24PVJU
Note
BYEP40AW1
BYEP63AW1
BRC1E73
BRC2A71
KRCS01-4B
KRP1C75
KRP4A74
KRP1B101
2
2
Note: *1. Electrical box (No.5-1/6-1) is required for controlIer (No. 5/6) *2. Adaptor mounting box (No.12) is necessary.
More than
40(1000)
More than 6 (150)
More than 10-15/64 (260)
FXEQ-PVJU INSTALLATION SPACE
More than 6 (150)
[Ceiling]
Air outlet
More than 6 (150)
Figure 2
Unit: [in. (mm)]
Figure 1
VRV Product Catalog
67
FXHQ-MVJU
Ceiling-Suspended Unit
Optional
Condensate Pump
Filter
Included
Slim, Efficient, Quiet, Easy to Maintain
With its slim, elegant design, the FXHQ ceiling-suspended
unit is a great fit for any light commercial space. Wide air
openings provide a comfortable airflow and an innovative
stream fan ensures quiet operation, making it ideal for retail
stores, restaurants, classrooms and conference rooms.
INDOOR UNITS
Features and Benefits
»» One of our slimmest indoor units (less than 8") fits
within any interior design
»» Wide air discharge outlet distributes a comfortable
airflow throughout the entire space with throw of
up to 25 ft.
»» Innovative stream fan technology keeps sound
pressure levels low
»» Smooth flat louver design makes cleaning simple
»» Long-life filter is standard
»» Models range from 12 MBH to 36 MBH
BRC1E73
(option)
Applications
68
www.daikincomfort.com
BRC7E83
(option)
Quiet Stream Fan (side view)
Uses the quiet stream fan and many more advanced technologies.
Sound absorption
member
Turbulent flow
is produced
»» Retail/shops
»» Offices
»» Restaurants
BRC2A71
(option)
Quiet stream fan
Straightening vane
FXHQ-MVJU SPECIFICATIONS
Model Name
Power Supply
Rated Cooling Capacity
Rated Heating Capacity
Airflow Rate (H/L)
Weight
Height
Width
Depth
Sound Pressure (H/L)
Condensate Pipe Connection
Gas
Liquid
Pipe Connections
Refrigerant
Refrigerant Control
Maximum Overcurrent Protective Device
Minimum Circuit Amps
Protection Devices
External Finish
Standard Filter Type
Nominal Conditions:
1 TON
FXHQ12MVJU
V/ph/Hz
BTU/h
BTU/h
CFM
lbs.
in.
in.
in.
dB(A)
in. O.D.
in.
in.
12,000
13,500
410/340
55
37-13/16
42/33
1/2 (Flare)
1/4 (Flare)
A
A
36,000
40,000
830/670
90
62-5/8
46/41
R-410A
Electronic Expansion Valve
15
1.0
Fuse and Fan Motor Thermal Protector
White Casing
Resin Net (with Mold Resistant)
Heating Mode
Indoor: 70 °F DB
Outdoor: 47 °F DB / 43 °F WB
Pipe Length: 25 ft.
Level Difference: 0 ft.
FXHQ12MVJU
KAFJ501D56
1.4
Note: Specifications are subject to change
without notice.
FXHQ24MVJU
BRC1E73
BRC2A71
BRC7E83
KRCS01-1B
KRP1C74
KRP4A72
KAFJ501D112
DACA-CP3-1
INDOOR UNITS
Cooling Mode
Indoor: 80 °F DB / 67 °F WB
Outdoor: 95 °F DB
Pipe Length: 25 ft.
Level Difference: 0 ft.
3 TON
FXHQ36MVJU
5/8 (Flare)
3/8 (Flare)
0.8
FXHQ-MVJU ACCESSORIES
Model Name
Navigation Remote Controller*
Simplified Wired Remote Controller*
Wireless Remote Controller
Remote Sensor Kit
Wiring Adapter PCB (interface with aux/primary heater, humidifier, OA damper/fan)
Group Control Adapter PCB (connects to external BMS)
Replacement long-life filter
Condensate Pump
*
2 TON
FXHQ24MVJU
208-230/1/60
24,000
27,000
710/600
80
7-11/16
55-1/8
26-3/4
44/36
1
FXHQ36MVJU
KAFJ501D160
Optional face plates available to provide a more intuitive user interface and disable specific functions
FXHQ-MVJU INSTALLATION SPACE
1-3/16" or more
Air outlet
Required service space
Air inlet
1-3/16" or more
12" or more
Obstruction
Floor
VRV Product Catalog
69
FXAQ-PVJU
Wall-Mounted Unit
Optional
Condensate Pump
Filter
Included
Stylish, Compact, Convenient, Comfortable
Daikin's wall-mounted units are ideal for cooling or heating
smaller zones such as stores, offices, and restaurants. The
compact, stylish design lets the unit blend discreetly into
any interior design, and airflow can be supplied in any of five
different directions and easily programmed via remote control.
INDOOR UNITS
Features and Benefits
»» Auto-swing mechanism ensures efficient air distribution via
louvers that automatically close when the unit is turned off
»» Wide air discharge outlet distributes a comfortable
airflow throughout the entire space
»» Horizontal louvers and front panel can be easily removed
for cleaning
»» Drain pipe can be easily hidden from sight
»» Models range from 7.5 MBH to 24 MBH
Applications
»» Retail
»» Restaurants
»» Offices
»» Hotels
»» Multi-family
residences
70
www.daikincomfort.com
BRC1E73
(option)
BRC2A71
(option)
BRC7E818
(option)
FXAQ-PVJU SPECIFICATIONS
Model Name
Power Supply
Rated Cooling Capacity
Rated Heating Capacity
Airflow Rate (H/L)
Weight
Height
Width
Depth
Sound Pressure (H/L)
Condensate Pipe Connection
Pipe Connections
Gas
Liquid
0.75 TON
FXAQ09PVJU
7,500
8,500
260/160
9,500
10,500
280/175
26
V/ph/Hz
BTU/h
BTU/h
CFM
lbs.
in.
in.
in.
dB(A)
in. O.D.
in.
in.
Refrigerant
Refrigerant Control
Maximum Overcurrent Protective Device
1 TON
FXAQ12PVJU
208-230/1/60
12,000
13,500
290/180
1.5 TON
FXAQ18PVJU
2 TON
FXAQ24PVJU
18,000
20,000
500/400
24,000
27,000
635/470
31
11-3/8
31-1/4
36/31
41-3/8
-1/4
38/31
11/16
37/31
43/37
47/41
1/2 (Flare)
1/4 (Flare)
5/8 (Flare)
3/8 (Flare)
R-410A
Electronic Expansion Valve
15
A
Minimum Circuit Amps
Protection Devices
External Finish
Standard Filter Type
A
0.4
0.5
0.6
Fuse and Fan Motor Thermal Protector
White Casing
Resin Net (washable)
Nominal Conditions:
Heating Mode
Indoor: 70 °F DB
Outdoor: 47 °F DB / 43 °F WB
Pipe Length: 25 ft.
Level Difference: 0 ft.
FXAQ07PVJU
FXAQ09PVJU
Note: Specifications are subject to change
without notice.
FXAQ12PVJU
BRC1E73
BRC2A71
BRC7E818
KRCS01-1B
KRP4A71
DACA-CP1-1
FXAQ18PVJU
INDOOR UNITS
Cooling Mode
Indoor: 80 °F DB / 67 °F WB
Outdoor: 95 °F DB
Pipe Length: 25 ft.
Level Difference: 0 ft.
FXAQ-PVJU ACCESSORIES
Model Name
Navigation Remote Controller*
Simplified Wired Remote Controller*
Wireless Remote Controller
Remote Sensor Kit
Group Control Adapter PCB (Connects to external BMS)
Condensate Pump
FXAQ24PVJU
Optional face plates available to provide a more intuitive user interface and disable specific functions
FXAQ-PVJU INSTALLATION SPACE
Installation panel (1)
≥ 3-1/2"
Temporary screw
(In case of 12 type)
≥ 2"
≥ 2"
≥ 1-1/4"
*
0.6 TON
FXAQ07PVJU
Left pipe
Obstruction
≤ 4-3/4"
≥ 100" (from floor)
For installation
in high places.
Back-left pipe
Bottom-left pipe
Back-right pipe
Floor
Fig.1
Fig.2
VRV Product Catalog
Fig.3
Bottom-right pipe
71
FXLQ-MVJU9
Floor-Standing Unit
Outside Air
Integration Possible
Filter
Included
Versatile, Logical, Durable, Quiet
The ideal way to save space, our floor-standing units can
easily be installed along a perimeter wall. The air distribution
from these models will allow you to find the right balance
for classrooms, churches, office hallways or similar spaces.
Features and Benefits
»» Ideal for installation beneath a window
INDOOR UNITS
»» Unit requires minimal installation space
»» Fitted with a washable long-life filter
»» Remote-control options available
»» Space-saving unit can be freestanding or wall-mounted
»» Models range from 7.5 MBH to 24 MBH
BRC1E73
(option)
Applications
»» Multi-family
residences
»» Single-family
residences
»» Churches
»» Historic buildings
»» Schools
»» Offices
72
www.daikincomfort.com
BRC2A71
(option)
BRC4C82
(option)
FXLQ-MVJU9 SPECIFICATIONS
Model Name
Power Supply
0.6 TON
FXLQ07MVJU9
0.75 TON
FXLQ09MVJU9
1 TON
FXLQ12MVJU9
V/ph/Hz
2 TON
FXLQ24MVJU9
24,000
208-230/1/60
Rated Cooling Capacity
BTU/h
7,500
9,500
12,000
18,000
Rated Heating Capacity
BTU/h
8,500
10,500
13,500
20,000
27,000
280/210
490/380
560/420
Airflow Rate (H/L)
CFM
245/210
Weight
lbs.
58
Height
in.
Width
in.
Depth
in.
Sound Pressure (H/L)
dB(A)
Condensate Pipe Connection
in. O.D.
in.
in.
Pipe Connections
Gas
Liquid
66
80
23-5/8
39-3/8
44-7/8
55-7/8
8-3/4
35/32
36/33
40/35
41/36
27/32
1/2 (Flare)
1/4 (Flare)
Refrigerant
5/8 (Flare)
3/8 (Flare)
R-410A
Electronic Expansion Valve
A
15
A
Nominal Conditions:
0.3
0.5
Fuse and Fan Motor Thermal Protector
Ivory White Casing
Resin Net (with Mold Resistant)
Cooling Mode
Indoor: 80 °F DB / 67 °F WB
Outdoor: 95 °F DB
Pipe Length: 25 ft.
Level Difference: 0 ft.
FXLQ-MVJU9 ACCESSORIES
Model Name
Navigation Remote Controller*
Simplified Wired Remote Controller*
Wireless Remote Controller
Remote Sensor Kit
Wiring Adapter PCB (interface with aux/primary heater,
humidifier, OA damper/fan)
Group Control Adapter PCB (connects to external BMS)
Heating Mode
Indoor: 70 °F DB
Outdoor: 47 °F DB / 43 °F WB
Pipe Length: 25 ft.
Level Difference: 0 ft.
FXLQ12MVJU9
FXLQ18MVJU9
0.6
INDOOR UNITS
Refrigerant Control
Maximum Overcurrent
Protective Device
Minimum Circuit Amps
Protection Devices
External Finish
Standard Filter Type
Note: Specifications are subject to change
without notice.
FXLQ24MVJU9
FXNQ12MVJU9
BRC1E73
BRC2A71
BRC4C82
KRCS01-1B
FXNQ18MVJU9
FXNQ24MVJU9
KRP1C74
KRP4A71
Optional face plates available to provide a more intuitive user interface and disable specific functions
FXLQ-MVJU9 INSTALLATION SPACE
3/4" or
more
4" or more
40" or more
*
1.5 TON
FXLQ18MVJU9
Front
side
4" or more
Air flow
direction
70" or more
Window
Air inlet
direction
Base
VRV Product Catalog
73
74
www.daikincomfort.com
Outdoor Units
VRV Product Catalog
75
Outdoor Units
Air-Cooled Condensers
VRV AURORA™ Heat Recovery
Heat Recovery
6 to 20 Tons 208-230V/60Hz/3ph
or 460V/60Hz/3ph
6 to 12 Tons 208-230V/60Hz/3ph
6 to 10 Tons 480V/60Hz/3ph
Daikin VRV AURORA Series heat
recovery systems introduce a new
benchmark for VRF technology by
integrating advanced technologies to
provide comfort, control, energy efficiency and reliability.
The Daikin VRV AURORA Series heat recovery systems set
a new industry standard for heating and cooling solutions by
delivering high heat capacities at low ambient applications.
»» Advanced continuous heating
during defrost cycle and oil return
for single module systems
»» Variable Refrigerant Temperature (VRT) control
»» Extended operating range with heating function down
to -4°F ambient air temperature
OUTDOOR UNITS
»» VRF Industry’s first air cooled system that delivers
heating down to -22°F (-30°C) as standard
»» Hot gas base pan circuit allows installation
without an additional drain pan heater
»» Designed to provide continuous heating
during defrost and oil return1
»» Engineered with Daikin vapor injection compressor
for optimized part load efficiencies
Heat Pump & Heat Recovery
6 to 381 Tons 208-230V/60Hz/3ph
or 460V/60Hz/3ph
Daikin's VRV IV systems integrate
advanced technology to provide
comfort control to help maximize
energy efficiency and reliability.
Currently available in heat pump and heat recovery
configurations, VRV IV provides a solution for multi-family
residential to large commercial applications desiring heating
or cooling. VRV IV is optimized for low total Life Cycle Cost
(LCC) with larger capacity single modules (now range up to
14 Tons), improved seasonal efficiency, as compared to VRV
III, with automatic and customizable Variable Refrigerant
Temperature (VRT) climate tuning and outstanding warranty2
with 10 year compressor and parts limited warranty
as standard.
The VRV IV is the first variable refrigerant flow (VRF)
system to be assembled in North America.
†
6 -ton model (RWEYQ72PC) is PC series. T and PC series models cannot be combined
to form multi-module systems.
††
Conditions/rules apply. Refer to Installation and Engineering Manual for further details.
Maximum 34 tons for Heat Pump
Complete warranty details available from your local distributor or
manufacturer's representative or at www.daikincomfort.com.
1
2
76
www.daikincomfort.com
or
Heat Pump
3, 4 and 5 Tons 208-230V/60Hz/1ph
The VRV IV S-series system is a highly
efficient solution for light commercial
buildings and residential applications
requiring heating and cooling of up to
9 zones. Space-saving design to fit in
tight areas and realize quick and easy installation. Single-supplier
reliability. The system — factory engineered and 80% complete
upon delivery — is fully optimized by Daikin.
Water Cooled Condensers
VRV T-Series Water Cooled Condensing
Unit Heat Pump/Heat Recovery
6 † to 36 Tons 208-230V/60Hz/3ph or
460V/60Hz/3ph
The VRV Water Cooled system combines
the characteristics of a water cooled system with the air
cooled VRV system and still use the same VRV indoor units,
similar refrigerant piping methods, branch selector boxes, and
controls as air cooled VRV systems. The main difference is
that heat is rejected or absorbed via the condensing units to
and from the 2-pipe water circuit instead of the outside air.
»» Flexible System design with increased diversity up to 150%††
»» Can be applied to both geothermal and boiler/tower applications
as standard with condenser water inlet temperature as low as
14°F†† in heating and 23°F†† in cooling is possible
»» Triple-stack capable to deliver up to 36 tons thanks to the
compact design
»» Engineered with heat rejection cancellation technology††
to eliminate mechanical room conditioning requirements
»» 2-9V variable water flow control logic†† as standard to
increase waterside system operational efficiencies
»» Drop-down switch box for easy service to key components
»» Field selectable top or front refrigerant connections for flexible
and easy installation
OUTDOOR UNITS
Local assembly of products
enables Daikin to react fast to
changes in the marketplace and
truly optimize the product for the
North American market.
VRV Product Catalog
77
Daikin VRV AURORA™
Heat Recovery
208-230V & 460V
Daikin VRV AURORA™ Series heat recovery systems
introduce a new benchmark for VRF technology by integrating
advanced technologies to provide comfort, control, energy
efficiency and reliability. The Daikin VRV AURORA Series heat
recovery systems set a new industry standard for heating and
cooling solutions by delivering high heat capacities at low
ambient applications.
Features and Benefits
replacement
compressor
*Complete warranty details available from your local distributor
or manufacturer’s representative or at www.daikincomfort.com.
Applications:
COLD CLIMATE
RESIDENTIAL
»» VRF Industry’s first air cooled system that delivers
heating down to -22°F (-30°C) as standard
»» Daikin’s patented inverter based vapor injection compressor
delivers high heating capacity of up to 100% at 0°F (-18°C),
up to 85% at -13°F (-25°C) and up to 60% at -22°F(-30°C)
»» Optimized efficiencies delivered by dedicated allinverter compressors and inverter fan motors
OUTDOOR UNITS
»» Refrigerant-cooled efficient and stable inverter board
operation, independent of ambient conditions
»» Hot gas base pan circuit allows installation
without an additional drain pan heater
»» Designed to provide continuous heating
during defrost and oil return**
»» Engineered with Daikin vapor injection compressor
for optimized part load efficiencies
»» Added peace of mind with Auto Changeover ability
to back up (auxiliary) heat
78
www.daikincomfort.com
OFFICE
RETAIL
SCHOOLS
»» Long pipe lengths up to 1640 ft total and ability to connect up to
41*** indoor units with up to 100 ft vertical separation between
indoor units provides design and installation flexibility
»» Corrosion resistant, 1000 hours salt spray tested Daikin PE
blue fin heat exchanger
»» Ships factory standard with coil guards
*Complete warranty details available from your local distributor
or manufacturer’s representative or at www.daikincomfort.com.
**Multi modules only for continuous heating during defrost
***Varies by model
IEER Ducted
IEER Mixed
SCHE Non-Ducted
SCHE Ducted
SCHE Mixed
COP @ 47°F Non-Ducted
COP @ 47°F Ducted
COP @ 47°F Mixed
COP @ 17°F Non-Ducted
COP @ 17°F Ducted
COP @ 17°F Mixed
EER Non-Ducted
EER Ducted
EER Mixed
RELQ72T
RELQ96T
RELQ120T
RELQ144T
RELQ192T
RELQ240T
IEER Non-Ducted
Product #
Capacity (Tons)
VRV AURORA HEAT RECOVERY CERTIFIED DATA - HEAT RECOVERY, 208-230V/60HZ/3PH AND 460V/60HZ/3PH
6
8
10
12
16
20
24.00
24.80
23.40
22.50
22.10
21.10
20.80
19.10
19.60
18.60
19.00
18.60
22.40
21.90
21.50
20.50
20.50
19.80
26.10
25.70
26.70
25.50
25.50
24.90
22.60
19.70
21.40
23.80
21.20
20.80
24.30
22.70
24.00
24.60
23.30
22.80
4.30
4.25
3.98
3.81
3.85
3.68
3.68
3.46
3.51
3.55
3.61
3.52
3.99
3.85
3.74
3.68
3.73
3.60
2.50
2.50
2.25
2.20
2.20
2.20
2.30
2.25
2.25
2.20
2.15
2.13
2.40
2.37
2.25
2.20
2.17
2.16
15.80
15.30
13.70
12.90
12.50
12.30
13.80
12.50
12.40
12.60
12.70
11.70
14.80
13.90
13.00
12.70
12.60
12.00
Certified efficiency data in accordance with ANSI/AHRI Standard 1230 2010, “Performance Rating of Variable Refrigerant Flow (VRF) Multi-Split Air Conditioning and Heat Pump Equipment” for the
VRV Series. The VRV AURORA™ Series has been designed and optimized to meet or exceed the latest minimum efficiency requirements in 10 C.F.R. Part 431 as determined by the U.S. Department of
Energy (DOE) and baseline efficiencies as defined by ASHRAE 90.1 2013. Systems under 65MBH are currently certified to AHRI 210/240. IEER ratings are as defined in ASHRAE 90.1 2013.
70
60
50
40
30
20
10
0
40
-10
30
-20
Range for pull-down operation
80
Range for pull-down operation
90
Range for continuous operation
Outdoor temperature (˚F WB)
50
Range for continuous operation
Outdoor temperature (˚F DB)
100
wind cover specification
requirements.
30
Range
Rangefor
forcontinuous
continuous operation
operation
60
Ambient temperature (˚F DB)
Heating
110
OUTDOOR UNITS
Cooling
TECHNICAL COOLING FEATURE FOR VRV RELQ-T
HEAT RECOVERY OUTDOOR UNITS
Technical Cooling Cooling
Cooling operation extended
110
from 23°F ambient air
temperature down to -4°.
100
The Technical Cooling feature
90
is engaged by field settings
on the outdoor unit and on
branch selector boxes. It
80
requires addition of wind
covers to the unit and
70
allows operation down
to -4° FDB ambient
60
temperature in cooling mode.
See the Engineering Data
50
book for complete application
rules and contact your local
40
Daikin representative for
Range for
for pull-down
pull-down operation
Range
DETAILED OPERATION RANGES FOR VRV RELQ-T HEAT RECOVERY OUTDOOR UNITS
20
10
0
20
50
-30
60
70
80
Indoor temperature (˚F WB)
90
50
60
70
80
90
Indoor temperature (˚F DB)
VRV Product Catalog
-10
60
70
80
Indoor temperature (˚F WB)
79
Daikin VRV AURORA™
Heat Recovery
208-230 & 460V (cont.)
»» Compressor technology with new spiral design and
injection valves for precise refrigerant control
»» Strong and efficient motors for optimized compressor
performance and part load efficiencies
»» Patented back pressure control mechanism
to minimize scroll pressure losses
TECHNICAL DATA FOR VRV AURORA RELQ-TATJU/TAYDU HEAT RECOVERY OUTDOOR UNITS
OUTDOOR UNITS
Model
Performance
Compressor
Refrigerant Piping,
Layout
Refrigerant Piping,
Connections
Connection Ratio
Electrical
Unit
1
2
Rated Cooling Capacity
Rated Heating Capacity
Operation Range Cooling
Operation Range Heating
Sound Pressure
Airflow (Cooling)
Airflow (Heating)
Fan ESP, Standard/Max
Compressors, all inverter
Revolutions per minute
Capacity Control Range
Maximum Vertical Pipe Length Above Unit
Maximum Vertical Pipe Length Below Unit
Maximum Vertical Pipe Length Between IDU
Maximum Actual Pipe Length
Maximum Equivalent Pipe Length
Maximum Total Pipe Length
Liquid Pipe (Main Line)
Suction Gas Pipe (Main Line)
Discharge Gas Pipe (Main Line)
Standard Connectable Indoor Unit Ratio
Maximum Number of Indoor Units
Maximum Overcurrent Protection, MOP (RELQ-TATJU / RELQ-TAYDU)
Minimum Circuit Amps, MCA (RELQ-TATJU / RELQ-TAYDU)
Compressor Rated Load Amps, RLA (RELQ-TATJU / RELQ-TAYDU)
Factory Refrigerant Charge
Weight
Dimensions (H x W x D)
Cooling operation can be extended down to -4ºF with application rules and conditions
Varies based on indoor model selected
80
6 Ton
RELQ72TATJU
RELQ72TAYDU
208-230V/3Ph/60Hz
460V/3Ph/60Hz
Combination
www.daikincomfort.com
BTU/h
BTU/h
°F (°C) DB
°F (°C) WB
dB(A)
CFM
CFM
in. W.G.
Qty
RPM
%
ft.
ft.
ft.
ft.
ft.
ft.
in.
in.
in.
%
Qty
A
A
A
lbs.
lbs.
in.
69,000
77,000
60
6956
7283
3738
11~100
3/8
3/4
5/8
12
70 / 35
60.8 / 28.1
20.7 / 9.4
727
8 Ton
RELQ96TATJU
RELQ96TAYDU
92,000
103,000
231 to 122
-22 to 60
61
7989
7283
0.12 / 0.32
1
3342
10~100
164 (295 With Field Setting)
131 (195 With Field Setting)
100
541
620
1,640
3/8
7/8
3/4
70 - 2002
16
80 / 45
76.5 / 39.8
36.8 / 16.6
25.8
793
66-11/16 X 48-7/8 X 30-3/16
10 Ton
RELQ120TATJU
RELQ120TAYDU
114,000
129,000
64
8806
7283
4350
9~100
1/2
1-1/8
3/4
20
90 / 50
83.4 / 43.4
39.3 / 17.8
793
Performance
Compressor
Refrigerant Piping,
Layout
Refrigerant Piping,
Connections
Connection Ratio
Electrical
Unit
Rated Cooling Capacity
Rated Heating Capacity
Operation Range Cooling
Operation Range Heating
Sound Pressure
Airflow (Cooling)
Airflow (Heating)
Fan ESP, Standard/Max
Compressors, all inverter
Revolutions per minute
Capacity Control Range
Maximum Vertical Pipe Length Above Unit
Maximum Vertical Pipe Length Below Unit
Maximum Vertical Pipe Length Between IDU
Maximum Actual Pipe Length
Maximum Equivalent Pipe Length
Maximum Total Pipe Length
Liquid Pipe (Main Line)
Suction Gas Pipe (Main Line)
Discharge Gas Pipe (Main Line)
Standard Connectable Indoor Unit Ratio
Maximum Number of Indoor Units
Maximum Overcurrent Protection, MOP (RELQ-TATJU / RELQ-TAYDU)
Minimum Circuit Amps, MCA (RELQ-TATJU / RELQ-TAYDU)
Compressor Rated Load Amps, RLA (RELQ-TATJU / RELQ-TAYDU)
Factory Refrigerant Charge
Weight
Dimensions (H x W x D)
BTU/h
BTU/h
°F (°C) DB
°F (°C) WB
dB(A)
CFM
CFM
in. W.G.
Qty
RPM
%
ft.
ft.
ft.
ft.
ft.
ft.
in.
in.
in.
%
Qty
A
A
A
lbs.
lbs.
in.
12 Ton
RELQ144TATJU
RELQ144TAYDU
2 x RELQ72T
138,000
154,000
16 Ton
20 Ton
RELQ192TATJU
RELQ240TATJU
RELQ192TAYDU
RELQ240TAYDU
2 x RELQ96T
2 x RELQ120T
184,000
228,000
206,000
256,000
231 to 122
-22 to 60
63
64
67
7283 + 7283
7989 + 7989
8806 + 8806
6956 + 6956
7283 + 7283
7283 + 7283
0.12 / 0.32
2
3786 + 3786
3294 + 3294
4230 + 4230
6~100
5~100
4~100
164 (295 With Field Setting)
131 (195 With Field Setting)
100
541
620
1,640
1/2
5/8
5/8
1-1/8
1-1/8
1-3/8
7/8
1-1/8
1-1/8
70 - 2002
25
33
41
70 + 70 / 35 + 35
80 + 80 / 45 + 45
90 + 90 / 50+ 50
60.8 + 60.8 / 28.1 + 28.1 76.5 + 76.5 / 39.8 + 39.8 83.4 + 83.4 / 43.4 + 43.4
21.6 + 21.6 / 9.8 + 9.8 38.1 + 38.1 / 17.3 + 17.3 40.4 + 40.4 / 18.3 + 18.3
25.8 + 25.8
2 x 727
2 x 793
2 x 793
66-11/16 X 48-7/8 X 30-3/16 + 66-11/16 X 48-7/8 X 30-3/16
VRV Product Catalog
OUTDOOR UNITS
Model
208-230V/3Ph/60Hz
460V/3Ph/60Hz
Combination
81
VRV IV
Air-Cooled
Heat Recovery
Daikin’s VRV IV systems integrate advanced technology
to provide comfort control with high energy efficiency and
reliability. VRV IV provides heating and cooling solutions for
multi-family residential to large commercial applications.
Daikin VRV IV is the first variable refrigerant flow (VRF) system
assembled in North America.
Features and Benefits
»» Total comfort solution for heating, cooling, ventilation
and controls.
»» Redesigned and optimized for low total Life Cycle
Cost (LCC).
»» Available in large capacity single modules up to 14 tons and
systems up to 38 tons allowing for flexible system design.
OUTDOOR UNITS
»» Year-round comfort and energy efficiency delivered
by combining VRV and VRT technologies.
»» Compatible with Daikin DVS series of Dedicated Outdoor
Air Systems (DOAS).
»» High energy efficiency with IEER values up to 29.3.
»» Integrated inverter technology delivers high
efficiency during part load conditions and
provides precise individual zone control.
»» Design flexibility with long piping lengths up to 3,280 ft.
total, and up to 100 ft. vertical separation between
indoor units.
»» Corrosion resistant 1000 hr. salt-spray tested
Daikin PE blue fin heat exchanger.
82
www.daikincomfort.com
»» Single/multiple port branch selector boxes provide compact
dimensions and a wide range of product offerings (single, 4,
6, 8, 10 and 12 port options).
»» Reduced commissioning time with VRV
configuration software and Graphical User
Interface (GUI), as compared to VRV III.
»» VRV IV takes advantage of Daikin's unique zone and
centralized controls that are optimized for the specific
needs of North America.
»» Outstanding 10-Year Limited Parts Warranty* as standard.
*Complete warranty details available from your local distributor
or manufacturer’s representative or at www.daikincomfort.com.
IEER Ducted
IEER Mixed
SCHE Non-Ducted
SCHE Ducted
SCHE Mixed
COP @ 47°F Non-Ducted
COP @ 47°F Ducted
COP @ 47°F Mixed
COP @ 17°F Non-Ducted
COP @ 17°F Ducted
COP @ 17°F Mixed
EER Non-Ducted
EER Ducted
EER Mixed
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
25.30
29.30
25.40
23.70
22.00
22.90
23.00
21.90
21.60
21.10
20.20
19.00
19.60
18.30
17.20
16.20
16.20
20.90
23.30
22.60
21.90
20.70
21.10
20.80
19.80
18.60
17.90
18.10
17.40
18.90
18.10
17.70
17.30
16.70
23.10
26.30
24.0
22.80
21.30
22.00
21.90
20.80
20.10
19.50
19.10
18.20
19.20
18.20
17.40
16.70
16.40
25.60
26.50
27.00
25.50
26.60
26.60
25.60
25.60
24.40
23.30
23.90
23.50
22.70
22.50
21.80
21.60
21.10
21.40
23.00
25.10
23.80
24.80
23.10
22.80
22.70
22.40
21.80
20.70
20.60
20.30
18.70
18.30
18.10
17.90
23.50
24.70
26.00
24.60
25.70
24.80
24.20
24.10
23.40
22.50
22.30
22.00
21.50
20.60
20.00
19.80
19.50
4.31
4.25
4.00
3.81
3.70
3.85
3.74
3.68
3.55
3.51
3.57
3.53
3.52
3.21
3.21
3.21
3.21
3.58
3.67
3.51
3.48
3.21
3.67
3.67
3.51
3.22
3.20
3.20
3.20
3.27
3.20
3.20
3.20
3.20
3.95
3.96
3.76
3.65
3.46
3.76
3.71
3.60
3.39
3.36
3.39
3.37
3.40
3.21
3.21
3.21
3.21
2.77
2.52
2.46
2.52
2.22
2.41
2.35
2.27
2.36
2.41
2.38
2.18
2.28
2.22
2.09
2.08
2.07
2.42
2.25
2.25
2.28
2.09
2.26
2.17
2.09
2.09
2.15
2.11
2.05
2.05
2.05
2.05
2.06
2.05
2.60
2.39
2.36
2.40
2.16
2.34
2.26
2.18
2.23
2.28
2.25
2.12
2.17
2.14
2.07
2.07
2.06
15.30
14.60
13.10
12.40
11.60
12.50
12.50
12.20
11.80
11.70
11.30
10.70
10.80
9.80
9.80
9.80
9.50
12.30
12.60
12.30
11.90
11.20
12.50
12.40
11.60
10.50
10.50
10.30
9.60
10.90
9.80
9.70
9.70
9.50
13.80
13.60
12.70
12.15
11.40
12.50
12.45
11.90
11.15
11.10
10.80
10.15
10.85
9.80
9.75
9.75
9.50
80
70
60
50
Outdoor temperature (˚F WB)
Rangefor
forcontinuous
continuous operation
operation
Range
Outdoor temperature (˚F DB)
90
40
30
20
10
0
40
-10
30
See the Engineering
Data book for complete
application rules and
contact your local Daikin
representative for wind
cover specification
requirements.
40
30
Range
Rangefor
forcontinuous
continuous operation
operation
50
Rangefor
forpull-down
pull-down operation
operation
Range
100
Rangefor
forcontinuous
continuous operation
operation
Range
Heating
60
Rangefor
forwarming
warmingup
up operation
operation
Range
Cooling
110
TECHNICAL COOLING FEATURE FOR VRV IV REYQ-T
HEAT RECOVERY OUTDOOR UNITS
Technical Cooling Cooling
Cooling operation
110
extended from 23°F
ambient air temperature
100
down to -4°.
90
The Technical Cooling
feature is engaged by field
80
settings on the outdoor
unit and on branch selector
boxes. It requires addition
70
of wind covers to the unit
and allows operation
60
down to -4° FDB
ambient temperature in
50
cooling mode.
Ambient temperature (˚F DB)
DETAILED OPERATION RANGES FOR VRV IV REYQ-T HEAT RECOVERY OUTDOOR UNITS
Range for
for pull-down
pull-down operation
Range
Certified efficiency data in accordance with ANSI/AHRI Standard 1230 2010, “Performance Rating of Variable Refrigerant Flow (VRF) Multi-Split Air Conditioning and Heat Pump Equipment” for the VRV Series.
The VRV IV Series has been designed and optimized to meet or exceed the latest minimum efficiency requirements in 10 C.F.R. Part 431 as determined by the U.S. Department of Energy (DOE) and baseline efficiencies
as defined by ASHRAE 90.1 2013. Systems under 65MBH are currently certified to AHRI 210/240. IEER ratings are as defined in ASHRAE 90.1 2013.
20
10
0
20
50
60
70
80
Indoor temperature (˚F WB)
90
-20
50
60
70
80
90
Indoor temperature (˚F DB)
VRV Product Catalog
-10
60
70
80
Indoor temperature (˚F WB)
83
OUTDOOR UNITS
REYQ72T
REYQ96T
REYQ120T
REYQ144T
REYQ168T
REYQ192T
REYQ216T
REYQ240T
REYQ264T
REYQ288T
REYQ312T
REYQ336T
REYQ360T
REYQ384T
REYQ408T
REYQ432T
REYQ456T
IEER Non-Ducted
Product #
Capacity (Tons)
VRV IV CERTIFIED DATA - HEAT RECOVERY, 208-230V/60HZ/3PH AND 460V/60HZ/3PH
VRV IV
Air-Cooled
Heat Recovery (cont.)
TECHNICAL DATA FOR VRV IV REYQ-TATJU/TAYDU HEAT RECOVERY OUTDOOR UNITS
6 Ton
8 Ton
10 Ton
12 Ton
14 Ton
16 Ton
208-230V/3Ph/60Hz
REYQ72TATJU REYQ96TATJU REYQ120TATJU REYQ144TATJU REYQ168TATJU REYQ192TATJU
Model
460V/3Ph/60Hz
REYQ72TAYDU REYQ96TAYDU REYQ120TAYDU REYQ144TAYDU REYQ168TAYDU REYQ192TAYDU
18 Ton
20 Ton
REYQ216TATJU
REYQ216TAYDU
REYQ240TATJU
REYQ240TAYDU
1 x REYQ120T
1 x REYQ72T
1 x REYQ120T
1 x REYQ96T
1 x REYQ144T
1 x REYQ96T
156,000
176,000
180,000
200,000
63
200,000
226,000
64
222,000
250,000
66
20.7 / 22.0
21.1 / 22.9
20.8 / 23.0
19.8 / 21.9
5,544 + 6,286
5,827 + 6,286
5,827 + 8,228
Combination
Performance
Compressor
Rated Cooling Capacity
Rated Heating Capacity
Sound Pressure
IEER (Ducted /
Non-Ducted)
Airflow
Fan ESP, Standard/Max
Compressors, all inverter
Revolutions per minute
OUTDOOR UNITS
Capacity Control Range
Maximum Vertical Pipe
Length Above Unit
Maximum Vertical Pipe
Length Below Unit
Maximum Vertical Pipe
Length Between IDU
Refrigerant
Piping, Layout Maximum Actual
Pipe Length
Maximum Equivalent
Pipe Length
Maximum Total Pipe
Length
Refrigerant
Piping,
Connections
Connection
Ratio
Electrical
67,000
75,000
58
90,000
100,000
20.9 / 25.3
CFM
in. W.G.
Qty
5,544
RPM
3600
3630, 3630
%
15-100
11-100
22.6 / 25.4
21.9 / 23.7
5,827
6,286
61
1
8,228
0.12 / 0.32
2
4470, 4470
4440, 4440
5190, 5190
ft.
541
ft.
620
ft.
in.
4
(4170, 4170) x 2
(4050, 4050),
(4110, 4110)
5-100
100
Discharge Gas Pipe,
Main Line
3
4080, (4290,
4290)
10-100
ft.
3,282
Ø1/2 (12.7) C1220T
Ø3/8 (9.5) C1220T
Ø5/8 (15.9) C1220T (Brazing Connection)
(Brazing Connection)
(Brazing Connection)
Ø3/4 (19.1)
Ø7/8 (22.2)
Ø1-3/8 (34.9) C1220T
C1220T (Brazing C1220T (Brazing
Ø1-1/8 (28.6) C1220T (Brazing Connection)
(Brazing Connection)
Connection)
Connection)
Ø5/8 (15.9)
Ø7/8 (22.2) C1220T
Ø3/4 (19.1) C1220T
C1220T (Brazing
Ø1-1/8 (28.6) C1220T (Brazing Connection)
(Brazing Connection)
(Brazing Connection)
Connection)
%
50 - 200
Qty
12
16
20
A
35/20
45/25
50/25
A
30.2 / 15.2
38 / 21.1
43 / 21.1
55 / 31.9
A
20.7 / 9.4
13.7 + 13.7 /
6.2 + 6.2
15 + 15 /
6.8 + 6.8
16.2 + 22.6 /
7.3 + 10.3
lbs.
21.9
lbs.
507 / 527
in.
66-11/16 x
36-11/16x
30-3/16
www.daikincomfort.com
25
29
33
37
41
35 + 50 / 20 + 25
45 + 50 / 25
+ 25
45 + 70 / 25 + 40
61.9 / 36.1
30.2 + 43 /
15.2 + 21.1
38 + 43 / 21.1
+ 21.1
38 + 55 / 21.1 + 31.9
17.4 + 24.4 /
7.9 + 11.1
20.7 + (15 + 15) /
9.4 + (6.8 + 6.8)
(13.7 + 13.7) +
(13.7 + 13.7) + (16.2 +
(15 + 15) /
22.6) / (6.2 + 6.2) +
(6.2 + 6.2) + (6.8
(7.3 + 10.3)
+ 6.8)
21.9 + 25.8
25.8 + 25.8
70/40
25.8
703 / 717
OPERATION RANGE FOR ALL VRV IV HEAT RECOVERY OUTDOOR UNITS
Cooling °F DB
-4* – 122
Heating °F WB
-13 – 60
*Application rules apply
84
65
131 (195 With Field Setting)
in.
Dimensions (H x W x D)
23.3 / 29.3
ft.
Suction Gas Pipe,
Main Line
Factory Refrigerant
Charge
Weight
(REYQ-TAT / REYQ-TAY)
134,000
150,000
164 (295 With Field Setting)
in.
Standard Connectable
Indoor Unit Ratio
Maximum Number of
Indoor Units
Maximum Overcurrent
Protection, MOP
(REYQ-TAT / REYQ-TAY)
Minimum Circuit
Amps, MCA
(REYQ-TAT / REYQ-TAY)
111,000
126,000
ft.
Liquid Pipe, Main Line
Compressor Rated
Load Amps, RLA
(REYQ-TAT / REYQ-TAY)
Unit
BTU/h
BTU/h
dB(A)
703 / 717
66-11/16 x 48-7/8 x 30-3/16
780 / 794
507 + 703 / 527 703 + 703 / 717
703 + 780 / 717 + 794
+ 717
+ 717
(66-11/16 x 48-7/8
x 30-3/16) + (66(66-11/16 x 48-7/8 x 30-3/16) +
(66-11/16 x 48-7/8 x 30-3/16)
11/16 x 36-11/16
x 30-3/16)
22 Ton
24 Ton
26 Ton
28 Ton
REYQ264TATJU REYQ288TATJU REYQ312TATJU REYQ336TATJU
REYQ264TAYDU REYQ288TAYDU REYQ312TAYDU REYQ336TAYDU
246,000
276,000
66
268,000
294,000
290,000
312,000
68
312,000
320,000
334,000
376,000
66
32 Ton
REYQ384TATJU
REYQ384TAYDU
1 x REYQ168T
1 x REYQ120T
1 x REYQ96T
356,000
386,000
68
18.6 / 21.6
17.9 / 21.1
18.1 / 20.2
17.4 / 19.0
18.9 / 19.6
18.1 / 18.3
6,286 + 8,228
8,228 + 8,228
1 x REYQ144T
1 x REYQ120T
1 x REYQ168T
1 x REYQ144T
2 x REYQ144T
30 Ton
REYQ360TATJU
REYQ360TAYDU
2 x REYQ168T
3 x REYQ120T
8,228 + 8,228
6,286 + 6,286 + 6,286
5,827 + 6,286 + 8,228
0.12/0.32
4
(4710, 4710),
(4800, 4800)
(4740, 4740) x 2
(5790, 5790) x 2
(5070, 5070) x
2, (5160, 5160)
(5010, 5010) x 3
5-100
34 Ton
REYQ408TATJU
REYQ408TAYDU
1 x REYQ168T
1 x REYQ144T
1 x REYQ96T
380,000
394,000
69
36 Ton
REYQ432TATJU
REYQ432TAYDU
38 Ton
REYQ456TATJU
REYQ456TAYDU
3 x REYQ144T
1 x REYQ168T
2 x REYQ144T
400,000
398,000
415,000
412,000
17.7 / 17.2
17.3 / 16.2
5,827 + 8,228 + 8,228
6
(5040, 5040),
(5130, 5130) x 2
3-100
70
16.7 / 16.2
8,228 + 8,228 + 8,228
(5220, 5220) x 3
(5730, 5730) x 3
164 (295 With Field Setting)
131 (195 With Field Setting)
OUTDOOR UNITS
100
541
620
3,282
Ø3/4 (19.1) C1220T (Brazing Connection)
Ø1-3/8 (34.9) C1220T (Brazing Connection)
Ø1-5/8 (41.3) C1220T (Brazing Connection)
Ø1-1/8 (28.6) C1220T (Brazing Connection)
Ø1-3/8 (34.9) C1220T (Brazing Connection)
50 - 200
45
49
54
50 + 70 / 25 + 40
43 + 55 /
21.1 + 31.9
58
70 + 70 / 40 + 40
55 + 55 /
31.9 + 31.9
55 + 61.9 /
31.9 + 36.1
61.9 + 61.9 /
36.1 + 36.1
(15 + 15) + (16.2 +
(16.2 + 22.6) + (17.4
(16.2 + 22.6 x 2 /
(17.4 + 24.4)x 2 /
22.6) / (6.8 + 6.8) +
+ 24.4) / (7.3 + 10.3)
(7.3 + 10.3) x 2
(7.9 + 11.1) x 2
(7.3 + 10.3)
+ (7.9 + 11.1)
64
50 + 50 + 50 / 25 +
25 + 25
45 + 50 + 70 / 25 + 25 + 40
45 + 70 + 70 / 25 + 40 + 40
70 + 70 + 70 /
40 + 40 + 40
70 + 70 + 70 /
40 + 40 + 40
43 + 43 + 43 /
21.1 + 21.1 + 21.1
38 + 43 + 61.9 /
21.1 + 21.1 + 21.1
38 + 55 + 61.9 /
21.1 + 31.9 + 36.1
55 + 55 + 55 /
31.9 + 31.9 + 31.9
55 + 55 + 61.9 /
31.9 + 31.9 + 36.1
(16.2 + 22.6) x 3 /
(7.3 + 10.3) x 3
(16.2 + 22.6) x 2 +
(17.4 + 24.4) / (7.3 +
10.3) x 2 + (7.9 + 11.1)
(15 + 15) x 3 /
(6.8 + 6.8) x 3
(13.7 + 13.7) + (16.2 + 22.6) (13.7 + 13.7) + (16.2 + 22.6)
+ (17.4 + 24.4) / (6.2 + 6.2) + + (17.4 + 24.4) / (6.2 + 6.2) +
(6.8 + 6.8) + (7.9 + 11.1)
(7.3 + 10.3) + (7.9 + 11.1)
25.8 + 25.8
703 + 780 /
717 + 794
780 + 780 / 794 + 794
(66-11/16 x 48-7/8 x 30-3/16) + (66-11/16 x 48-7/8 x 30-3/16)
25.8 + 25.8 + 25.8
703 + 703 + 703 /
717 + 717 + 717
703 + 703 + 780 /
717 + 717 + 794
780 + 780 + 780 /
717 + 794 + 794
780 + 780 + 780 /
794 + 794 + 794
(66-11/16 x 48-7/8 x 30-3/16) + (66-11/16 x 48-7/8 x 30-3/16) + (66-11/16 x 48-7/8 x 30-3/16)
For additional technical information please refer to specific Engineering Data Books.
VRV Product Catalog
85
VRV IV
Air-Cooled
Heat Pump
Daikin’s VRV IV systems integrate advanced technology to
provide comfort control helping to maximize energy efficiency
and reliability. VRV IV provides heating and cooling solutions
for multi-family residential to large commercial applications.
Daikin VRV IV is the first variable refrigerant flow (VRF) system
assembled in North America.
Features and Benefits
»» Total comfort solution for heating, cooling, ventilation
and controls.
»» Redesigned and optimized for low total Life Cycle
Cost (LCC).
»» Available in large capacity single modules up to 14 tons
and systems up to 34 tons allowing for a more flexible
system design.
»» Year-round comfort and energy efficiency delivered
OUTDOOR UNITS
by combining VRV and VRT technologies.
»» High energy efficiency with IEER values up to 27.3.
»» Integrated inverter technology delivers high efficiency
during part load conditions and provides precise individual
zone control.
»» Design flexibility with long piping lengths up to 3,280 ft.
total, and up to 100 ft. vertical separation between
indoor units.
»» Corrosion resistant 1000 hr. salt-spray tested Daikin PE
blue fin heat exchanger.
86
www.daikincomfort.com
»» Reduced commissioning time with VRV configuration
software and Graphical User Interface (GUI), as compared
to VRV III.
»» VRV IV takes advantage of Daikin's unique zone and
centralized controls that are optimized for the specific
needs of North America.
»» Outstanding 10-year limited parts warranty* as standard.
*Complete warranty details available from your local distributor
or manufacturer’s representative or at www.daikincomfort.com.
IEER Ducted
IEER Mixed
COP @ 47°F Non-Ducted
COP @ 47°F Ducted
COP @ 47°F Mixed
COP @ 17°F Non-Ducted
COP @ 17°F Ducted
COP @ 17°F Mixed
EER Non-Ducted
EER Ducted
EER Mixed
RXYQ72T
RXYQ96T
RXYQ120T
RXYQ144T
RXYQ168T
RXYQ192T
RXYQ216T
RXYQ240T
RXYQ264T
RXYQ288T
RXYQ312T
RXYQ336T
RXYQ360T
RXYQ384T
RXYQ408T
IEER Non-Ducted
Product #
Capacity (Tons)
VRV IV CERTIFIED DATA - HEAT PUMP, 208-230V/60HZ/3PH AND 460V/60HZ/3PH
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
25.90
27.30
25.40
24.80
22.60
22.20
20.50
20.80
20.30
20.10
19.90
20.60
19.40
21.10
21.10
20.70
22.50
22.00
22.60
19.80
21.20
21.10
20.90
19.60
19.60
18.80
18.50
18.50
18.50
19.00
23.30
24.90
23.70
23.70
21.20
21.70
20.80
20.80
19.80
19.80
19.30
19.50
18.90
19.80
20.00
3.88
4.21
3.56
3.67
3.40
3.68
3.83
3.63
3.33
3.25
3.30
3.22
3.46
3.30
3.24
3.30
3.49
3.30
3.34
3.20
3.29
3.50
3.33
3.27
3.30
3.21
3.20
3.20
3.20
3.20
3.59
3.85
3.43
3.51
3.30
3.49
3.67
3.48
3.30
3.28
3.26
3.21
3.33
3.25
3.22
2.49
2.71
2.25
2.33
2.34
2.27
2.60
2.43
2.43
2.07
2.32
2.38
2.47
2.28
2.18
2.25
2.48
2.37
2.20
2.27
2.23
2.46
2.34
2.30
2.13
2.20
2.27
2.36
2.28
2.10
2.37
2.60
2.31
2.27
2.31
2.25
2.53
2.39
2.37
2.10
2.26
2.33
2.42
2.28
2.14
14.80
14.30
12.40
12.30
10.60
11.50
10.70
11.30
10.80
10.50
9.80
9.50
10.30
9.50
9.50
12.70
12.60
11.60
11.50
10.60
11.60
10.90
11.20
9.90
10.10
9.60
9.50
9.80
9.50
9.50
13.80
13.50
12.00
11.90
10.60
11.60
10.80
11.30
10.40
10.30
9.70
9.50
10.50
9.50
9.50
DETAILED OPERATION RANGES FOR VRV IV RXYQ-T HEAT PUMP OUTDOOR UNITS
60
100
30
20
10
40
Ambient temperature (˚F DB)
50
40
Rangefor
for continuous
continuous operation
operation
Range
60
Rangefor
forwarming
warmingup
up operation
operation
Range
70
Outdoor temperature (˚F WB)
Outdoor temperature (˚F DB)
80
Range
Range for
for pull-down
pull-down operation
operation
Range for
for continuous
continuous operation
operation
Range
50
90
30
20
10
0
30
40
Range for
for pull-down
pull-down operation
Range
Heating
110
Range
Rangefor
forcontinuous
continuous operation
operation
Cooling
LOW AMBIENT COOLING OPERATION FOR VRV IV RXYQ-T SINGLE
MODULE HEAT PUMP OUTDOOR UNITS
Cooling operation may
Cooling
be extended from 23°F
110
ambient air temperature
down to 10°F.
100
Cooling operation
90
may be extended for
single module heat
80
pump systems under
certain conditions. See
the Engineering Data
70
book for complete
application rules, or
60
contact your local Daikin
representative for more
50
information.
0
20
50
60
70
80
Indoor temperature (˚F WB)
90
-10
50
60
70
80
Indoor temperature (˚F DB)
90
-10
60
70
80
Indoor temperature (˚F WB)
See the Engineering Data book for complete application rules.
VRV Product Catalog
87
OUTDOOR UNITS
Certified efficiency data in accordance with ANSI/AHRI Standard 1230 2010, “Performance Rating of Variable Refrigerant Flow (VRF) Multi-Split Air Conditioning and Heat Pump Equipment” for the VRV Series.
The VRV IV Series has been designed and optimized to meet or exceed the latest minimum efficiency requirements in 10 C.F.R. Part 431 as determined by the U.S. Department of Energy (DOE) and baseline efficiencies
as defined by ASHRAE 90.1 2013. Systems under 65MBH are currently certified to AHRI 210/240. IEER ratings are as defined in ASHRAE 90.1 2013.
VRV IV
Air-Cooled
Heat Pump (cont.)
TECHNICAL DATA FOR VRV IV RXYQ-TATJU/TAYDU HEAT PUMP OUTDOOR UNITS
6 Ton
8 Ton
10 Ton
12 Ton
14 Ton
208-230V/3Ph/60Hz
RXYQ72TATJU RXYQ96TATJU RXYQ120TATJU RXYQ144TATJU RXYQ168TATJU
Model
460V/3Ph/60Hz
RXYQ72TAYDU RXYQ96TAYDU RXYQ120TAYDU RXYQ144TAYDU RXYQ168TAYDU
Combination
Rated Cooling Capacity
Rated Heating Capacity
Sound Pressure
Performance IEER (Ducted /
Non-Ducted)
Airflow
Fan ESP, Standard/Max
Compressors, all
inverter
Compressor
Revolutions per minute
OUTDOOR UNITS
Refrigerant
Piping,
Layout
Capacity Control Range
Maximum Vertical Pipe
Length Above Unit
Maximum Vertical Pipe
Length Below Unit
Maximum Vertical Pipe
Length Between IDU
Maximum Actual
Pipe Length
Maximum Equivalent
Pipe Length
Maximum Total Pipe
Length
Liquid Pipe, Main Line
Refrigerant
Piping,
Connections Suction Gas Pipe,
Main Line
Connection
Ratio
Electrical
Unit
Standard Connectable
Indoor Unit Ratio
Maximum Number of
Indoor Units
Maximum Overcurrent
Protection, MOP
(RXYQ-TAT / RXYQ-TAY)
Minimum Circuit
Amps, MCA
(RXYQ-TAT / RXYQ-TAY)
Compressor Rated Load
Amps, RLA
(RXYQ-TAT / RXYQ-TAY)
Factory Refrigerant
Charge
Weight
(RXYQ-TAT / RXYQ-TAY)
Dimensions (H x W x D)
BTU/h
BTU/h
dB(A)
CFM
in. W.G.
69,000
73,000
58
92,000
103,000
20.7 / 25.9
5,544
Qty
18 Ton
RXYQ216TATJU
RXYQ216TAYDU
20 Ton
RXYQ240TATJU
RXYQ240TAYDU
1 x RXYQ120T
1 x RXYQ72T
1 x RXYQ120T
1 x RXYQ96T
2 x RXYQ120T
228,000
256,000
114,000
129,000
138,000
154,000
64
160,000
176,000
65
184,000
206,000
63
206,000
230,000
22.5 / 27.3
22 / 25.4
22.6 / 24.8
19.8 / 22.6
21.2 / 22.2
21.1 / 20.5
20.9 / 20.8
5,827
6286
5544 + 6286
5827 + 6286
6286 + 6286
61
8,228
0.12 / 0.32
1
7668
7650
7746
7008 + 7608
7680 + 8280
7668, 7746
%
20-100
16-100
15-100
11-100
10-100
17-100
ft.
164 (295 With Field Setting)
ft.
130 (295 With Field Setting)
ft.
100
ft.
540
ft.
620
ft.
in.
in.
64
2
RPM
7650, 7746
7746, 7746
15-100
3,280
Ø3/8 (9.5) C1220T
(Brazing Connection)
Ø3/4 (19.1)
Ø7/8 (22.2)
C1220T (Brazing C1220T (Brazing
Connection)
Connection)
Ø1/2 (12.7) C1220T
(Brazing Connection)
Ø5/8 (15.9) C1220T (Brazing Connection)
Ø1-3/8 (34.9)
C1220T (Brazing
Connection)
Ø1-1/8 (28.6) C1220T (Brazing Connection)
%
50 - 200
Qty
12
A
35 / 20
A
27.6 /
12.3
36.3 /
20.6
A
15.7 /
7.1
lbs.
13
lbs.
435 / 451
in.
66-11/16 ×
36-11/16 ×
30-3/16
16
25
29
33
37
41
www.daikincomfort.com
20
60 / 35
60 / 35
35 + 45 / 20 + 25
45 + 45 / 25+25
45 + 45 / 25 + 25
36.3 /
20.6
55.1 /
25.9
55.1 /
25.9
27.6 + 36.3 /
12.3 + 20.6
36.3 + 36.3 /
20.6 + 20.6
36.3 + 36.3 /
20.6 + 20.6
23.8 /
10.2
26.2 /
11.7
16.7 + 16.7 /
7.6 + 7.6
18.8 + 18.8 /
8.5 + 8.5
15.7 + 26.2 /
7.1 + 11.7
23.8 + 26.2 /
10.2 + 11.7
26.2 + 26.2 /
11.7 + 11.7
22.7
22.9
18.1
17.2
45 / 25
525 / 553
OPERATION RANGE FOR ALL VRV IV HEAT PUMP OUTDOOR UNITS
Cooling °F DB
10* – 122
Heating °F WB
-4 – 60
*Application rules apply
88
16 Ton
RXYQ192TATJU
RXYQ192TAYDU
528 / 556
695 / 709
66-11/16 × 48-7/8 × 30-3/16
13.0 + 22.9
22.7 + 22.9
22.9 + 22.9
435 + 528 /
451 + 556
66-11/16 ×
48-7/8 × 30-3/16 +
66-11/16 × 36-11/16
× 30-3/16
525 + 528 / 553
+ 556
528 + 528 /
556 + 556
(66-11/16 × 48-7/8 × 30-3/16) x 2
22 Ton
RXYQ264TATJU
RXYQ264TAYDU
24 Ton
RXYQ288TATJU
RXYQ288TAYDU
26 Ton
RXYQ312TATJU
RXYQ312TAYDU
28 Ton
RXYQ336TATJU
RXYQ336TAYDU
30 Ton
RXYQ360TATJU
RXYQ360TAYDU
1 x RXYQ144T
1 x RXYQ120T
2 x RXYQ144T
1 x RXYQ168T
1 x RXYQ144T
2 x RXYQ168T
3 x RXYQ120T
250,000
282,000
66
274,000
308,000
67
296,000
334,000
312,000
344,000
334,000
372,000
66
19.6 / 20.3
19.6 / 20.1
18.8 / 19.9
18.5 / 20.6
18.5 / 19.4
18.5 / 21.1
19.0 / 21.1
6286 + 6286 + 6286
5827 + 6286 + 8228
6286 + 6286 + 8228
3
4
5
7746, 7746, 7746
7650, 7746, (7680, 8280)
7650, (7008, 7608), (7680, 8280)
15-100
13-100
12-100
6286 + 8228
68
8228 + 8228
32 Ton
RXYQ384TATJU
RXYQ384TAYDU
1 x RXYQ168T
1 x RXYQ120T
1 x RXYQ96T
352,000
400,000
34 Ton
RXYQ408TATJU
RXYQ408TAYDU
1 x RXYQ168T
1 x RXYQ144T
1 x RXYQ96T
372,000
435,000
68
0.12 / 0.32
3
7746, (7008, 7608)
13-100
4
(7008, 7608),
(7008, 7608)
11-100
(7008, 7608), (7680, 8280)
(7680, 8280),
(7680, 8280)
10-100
164 (295 With Field Setting)
OUTDOOR UNITS
131 (295 With Field Setting)
100
541
620
3,280
Ø3/4 (19.1) C1220T (Brazing Connection)
Ø1-3/8 (34.9) C1220T (Brazing Connection)
Ø1-5/8 (41.3) C1220T (Brazing Connection)
50 - 200
45
49
54
58
62
64
45 + 60 / 25 + 35
60 + 60 / 35 + 35
45 + 45 + 45 / 25 + 25 + 25
45 + 45 + 60 / 25 + 25 + 35
45 + 60 + 60 / 25 + 35 + 35
36.3 + 55.1 / 20.6 + 25.9
55.1 + 55.1 / 25.9 + 25.9
36.3 + 36.3 + 36.3 /
20.6 + 20.6 + 20.6
36.3 + 36.3 + 55.1 /
20.6 + 20.6 + 25.9
36.3 + 55.1 + 55.1 /
20.6 + 25.9 + 25.9
23.8 + 26.2 + (18.8 + 18.8) /
10.2 + 11.7 + (8.5 + 8.5)
23.8 + (16.7 + 16.37) +
(18.8 + 18.8) / 10.2 +
(7.6 + 7.6) + (8.5 + 8.5)
26.2 + (16.7 + 16.7) /
11.7 + (7.6 + 7.6)
(16.7 + 16.7) x 2 /
(7.6 + 7.6) x 2
(16.7 + 16.7) +
(18.8 + 18.8) /
(7.6 + 7.6) + (8.5 + 8.5)
(18.8 + 18.8) x
2 / (8.5 + 8.5) x 2
26.2 + 26.2 + 26.2 /
11.7 + 11.7 + 11.7
22.9 + 18.1
18.1 + 18.1
18.1 + 17.2
17.2 + 17.2
22.9 + 22.9 + 22.9
22.7 + 22.9 + 17.2
22.7 + 18.1 + 17.2
528 + 528 + 528 /
525 + 528 + 695
525 + 528 + 695 /
553 + 556 + 709
525 + 695 + 695 /
553 + 709 + 709
528 + 695 / 556 + 709
695 + 695 / 709 + 709
(66-11/16 x 48-7/8 x 30-3/16) x 2
(66-11/16 x 48-7/8 x 30-3/16) x 3
For additional technical information please refer to specific Engineering Data Books.
VRV Product Catalog
89
VRV-III PC
Air-Cooled
Heat Recovery
Daikin’s VRV III systems integrate advanced technology to
provide comfort control to help maximize energy efficiency.
Available in heat recovery configurations, VRV III provides
a solution for residential to large commercial applications
desiring heating, cooling, or simultaneous operation.
Features and Benefits
»» Advanced continuous heating during defrost cycle and oil
return for single module systems
»» Variable Refrigerant Temperature (VRT) control
»» Extended operating range with heating function -4°F
ambient air temperature
IEER Ducted
IEER Mixed
COP @ 47°F Non-Ducted
COP @ 47°F Ducted
COP @ 47°F Mixed
COP @ 17°F Non-Ducted
COP @ 17°F Ducted
COP @ 17°F Mixed
EER Non-Ducted
EER Ducted
EER Mixed
REYQ72PC
REYQ96PC
REYQ120PC
REYQ144PCTJ
IEER Non-Ducted
Product #
Capacity (Tons)
OUTDOOR UNITS
VRV III PC CERTIFIED DATA - HEAT RECOVERY, 208-230V/60HZ/3PH AND 460V/3PH/60HZ
6
8
10
12
25.1
22.9
21.3
18.9
18.7
17.6
15.3
15.3
21.9
20.3
18.3
17.1
4.2
3.7
3.6
3.6
3.6
3.4
3.2
3.2
3.9
3.6
3.4
3.4
2.95
2.7
2.6
2.95
2.4
2.4
2.95
2.95
2.7
2.6
2.4
2.3
15.4
13.2
12.1
11.2
12.3
11.0
10.9
10.0
13.9
12.1
11.5
10.6
Certified efficiency data in accordance with ANSI/AHRI Standard 1230 2010, “Performance Rating of Variable Refrigerant Flow (VRF) Multi-Split Air Conditioning and Heat Pump Equipment” for the VRV Series.
The VRV III Series has been designed and optimized to meet or exceed the latest minimum efficiency requirements in 10 C.F.R. Part 431 as determined by the U.S. Department of Energy (DOE) and baseline efficiencies
as defined by ASHRAE 90.1 2010. Systems under 65MBH are currently certified to AHRI 210/240. IEER ratings are as defined in ASHRAE 90.1 2010.
90
www.daikincomfort.com
TECHNICAL DATA FOR VRV III PC REYQ-PC HEAT RECOVERY OUTDOOR UNITS
208-230V/3Ph/60Hz
460V/3Ph/60Hz
Model
Rated Cooling Capacity
Rated Heating Capacity
Sound Pressure (REYQ-PCT / REYQ-PCY)
Performance
IEER (Ducted / Non-Ducted)
Airflow
Fan ESP, Standard/Max
Compressors, standard / inverter
Compressor
Revolutions per minute
Capacity Control Range
Maximum Vertical Pipe Length Above Unit
Maximum Vertical Pipe Length Below Unit
Refrigerant Piping, Maximum Vertical Pipe Length Between IDU
Layout
Maximum Actual Pipe Length
Maximum Equivalent Pipe Length
Maximum Total Pipe Length
Liquid Pipe, Main Line
BTU/h
BTU/h
dB(A)
CFM
in. W.G.
Qty
RPM
%
ft.
ft.
ft.
ft.
ft.
ft.
in.
Refrigerant Piping, Suction Gas Pipe, Main Line
Connections
Discharge Gas Pipe, Main Line
Connection Ratio
Electrical
Unit
in.
in.
Standard Connectable Indoor Unit Ratio
Maximum Number of Indoor Units
Maximum Overcurrent Protection, MOP (REYQ-PCT / REYQ-PCY)
Minimum Circuit Amps, MCA (REYQ-PCT / REYQ-PCY)
Compressor Rated Load Amps, RLA (REYQ-PCT / REYQ-PCY)
Factory Refrigerant Charge
Weight (REYQ-PCT / REYQ-PCY)
Dimensions (H x W x D)
%
Qty
A
A
A
lbs.
lbs.
in.
6 Ton
REYQ72PCTJ
REYQ72PCYD
69,000
77,000
58 / 58
21.3 / 25.1
8 Ton
REYQ96PCTJ
REYQ96PCYD
90,000
103,000
58 / 61
19.7 / 22.9
10 Ton
REYQ120PCTJ
REYQ120PCYD
110,000
129,000
60 / 61
16.1 / 21.3
7,410
6,700
12 Ton
REYQ144PCTJ
–
124,000
148,000
62 / –
16.5 / 18.9
8,300
0.12 / 0.32
2
3720, 2900
20–100
6300, 2900
6300, 2900
7980, 7880
14–100
10–100
131 (295 With Field Setting)
164 (295 With Field Setting)
49
541
620
3,282
Φ3/8 (9.5) C1220T (Brazing Connection)
Φ1/2 (12.7) C1220T (Brazing Connection)
Φ7/8 (22.2) C1220T
Φ3/4 (19.1) C1220T
Φ1-1/8 (28.6) C1220T (Brazing Connection)
(Brazing Connection)
(Brazing Connection)
Φ5/8 (15.9) C1220T
Φ7/8 (22.2) C1220T
Φ3/4 (19.1) C1220T (Brazing Connection)
(Brazing Connection)
(Brazing Connection)
36–93
48–124
60–156
72–187
12
16
20
25
40 / 20
45 / 25
50 / 25
80 / –
36.1 / 16.0
43.8 / 20.4
44.2 / 20.5
72.2 / –
4.8 + 14.0 / 2.4 + 7.0
8.4 + 14.0 / 4.2 + 7.0
12.0 + 13.6 / 6.0 + 6.8
14.3 + 14.3 / –
22.7
23.4
23.8
24.5
730 / 732
747
66-1/8 x 51-3/16 x 30-1/8
60
100
50
30
20
10
40
Ambient temperature (˚F DB)
60
40
Range
operation
Rangefor
for continuous
continuous operation
70
Range
for
Range
forwarming
warmingup
upoperation
operation
80
Outdoor temperature (˚F WB)
Outdoor temperature (˚F DB)
90
Range
Range
forfor
pull-down
pull-downoperation
operation
Range
forforcontinuous
Range
continuousoperation
operation
50
0
30
20
-10
50
60
70
80
Indoor temperature (˚F WB)
90
50
60
70
80
Indoor temperature (˚F DB)
90
See the Engineering Data book for complete application rules.
-10
Range
operation
Rangefor
for pull-down
pull-down operation
Heating
Cooling
110
TECHNICAL COOLING FEATURE FOR
VRV III PC (REYQ-PC) HEAT RECOVERY OUTDOOR UNITS
Technical Cooling
Cooling
- Cooling operation
110
extended from
23°F ambient air
100
temperature down
to -4°F.
90
The Technical Cooling
feature is engaged by
80
field settings on the
outdoor unit and on
70
branch selector boxes.
It requires addition of
60
wind covers to the unit
and allows operation
50
down to -4° FDB
ambient temperature
in cooling mode.
40
See the Engineering
30
Data book for
complete application
rules and contact
20
your local Daikin
representative for wind
10
cover specification
requirements.
0
Range
Range for
for continuous
continuous operation
operation
DETAILED OPERATION RANGES FOR VRV III PC (REYQ-PC) HEAT RECOVERY OUTDOOR UNITS
OUTDOOR UNITS
OPERATION RANGE FOR ALL VRV III PC HEAT RECOVERY OUTDOOR UNITS
Cooling °F DB
23 – 122
Heating °F WB
-4 – 60
60
70
80
Indoor temperature (˚F WB)
For additional technical information please refer to specific Engineering Data Books.
VRV Product Catalog
91
VRV T-Series Water Cooled
Heat Pump / Heat Recovery
208-230V / 460V
VRV T-Series Water Cooled systems are equivalent to 4-pipe
chilled water systems, but also offer a viable alternative to
Water Source Heat Pump solutions. Each connected indoor
unit can provide heating and cooling independently to suit
zone requirements making these systems suitable for
both open plan, or cellar applications with different
operation requirements.
Features and Benefits
»» Flexible System design with increased diversity up to 150%1
compared to previous VRV water cooled generation
»» Triple-stack capable to deliver up to 36 tons
in 10.5 ft ceiling height
»» Flexible and easy installation with field selectable
top or front refrigerant connections
OUTDOOR UNITS
»» Design flexibility with long piping lengths up to 980 ft.
total (540 ft. max. linear liquid piping length) and up
to 100 ft. vertical separation between indoor units
»» Engineered with heat rejection cancellation technology2
to minimize mechanical room conditioning requirements
»» Year round comfort and energy efficiency by
combining VRV and VRT technologies
Water side
Refrigerant side
Connects to cooling
tower and/or boiler
combination or set up
as geothermal.
Connects to
Daikin’s line-up of
VRV indoor units
»» Wide water temperature operation range - Can be
applied to both geothermal and boiler/tower applications
as standard with condenser water inlet temperature as
low as 14°F in heating and 23°F in cooling is possible.
»» 2-9V variable water flow control logic2 as standard to
increase waterside system operational efficiencies
»» Refrigerant cooled inverter technology to deliver
consistent and reliable PCB operations
»» Easy commissioning with ability to program
settings off site using new configurator tool
The condensers are
smaller and can be
stacked, reducing
the installation space
and increasing the
customers' usable
square footage.
»» 3-digit 7-segment digital display on the unit for improved
and faster configuration, commissioning, and troubleshooting
»» Engineered for easy service with drop-down switch box
to access key components
Model specific, check product specification for details
Refer to installation manual for field settings and other requirements
to activate this feature
1
2
VRV Water Cooled System Series design is based on
a modular design concept. It is composed of unified
condensing units that require simply connecting a two-pipe
refrigerant network for heat pump applications or a threepipe refrigerant network for heat recovery applications.
Water-cooled condensers are available in 6*, 8, 10 and 12 tons.
92
www.daikincomfort.com
This is a simple system that allows manifolding together up
to three condensers to form one system of up to 36 tons.
The condensers are designed for internal mounting only.
*6-ton model (RWEYQ72PC) is PC series. T and PC series models cannot be
combined to form multi-module systems.
Tonnage
IEER Non-Ducted
IEER Ducted
IEER Mixed
SCHE Non-Ducted
(Heat Recovery only)
SCHE Ducted
(Heat Recovery only)
SCHE Mixed
(Heat Recovery only)
EER Non-Ducted
EER Ducted
EER Mixed
COP @ 68°F Non-Ducted
COP @ 68°F Ducted
COP @ 68°F Mixed
RWEYQ72PCTJU
RWEQ96TATJU
RWEQ120TATJU
RWEYQ144PCTJ
RWEYQ192PCTJ
RWEQ216TATJU
RWEQ240TATJU
RWEQ264TATJU
RWEQ288TATJU
RWEQ312TATJU
RWEQ336TATJU
RWEQ360TATJU
RWEQ384TATJU
RWEQ408TATJU
RWEQ432TATJU
RWEYQ72PCTJ
RWEQ96TATJU
RWEQ120TATJU
RWEYQ144PCTJ
RWEYQ192PCTJ
RWEQ216TATJU
RWEQ240TATJU
RWEQ264TATJU
RWEQ288TATJU
RWEQ312TATJU
RWEQ336TATJU
RWEQ360TATJU
RWEQ384TATJU
RWEQ408TATJU
RWEQ432TATJU
6 Tons
8 Tons
10 Tons
12 Tons
16 Tons
18 Tons
20 Tons
22 Tons
24 Tons
26 Tons
28 Tons
30 Tons
32 Tons
34 Tons
36 Tons
6 Tons
8 Tons
10 Tons
12 Tons
16 Tons
18 Tons
20 Tons
22 Tons
24 Tons
26 Tons
28 Tons
30 Tons
32 Tons
34 Tons
36 Tons
24.10
30.80
29.40
24.30
26.80
26.30
25.90
23.50
20.90
21.90
21.50
21.20
19.50
18.20
17.00
24.10
30.80
29.40
24.30
26.80
26.30
25.90
23.50
20.90
21.90
21.50
21.20
19.50
18.20
17.00
22.30
25.40
23.50
21.90
24.70
23.80
22.70
20.00
18.80
21.80
21.40
20.20
17.90
17.20
16.60
22.30
25.40
23.50
21.90
24.70
23.80
22.70
20.00
18.80
21.80
21.40
20.20
17.90
17.20
16.60
23.20
28.10
26.45
23.10
25.75
25.05
24.30
21.75
19.85
21.85
21.45
20.70
18.70
17.70
16.80
23.20
28.10
26.45
23.10
25.75
25.05
24.30
21.75
19.85
21.85
21.45
20.70
18.70
17.70
16.80
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
17.80
25.70
26.30
26.50
26.00
25.70
25.40
25.20
23.50
24.50
23.50
23.20
22.00
21.20
20.50
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
19.20
21.30
22.50
22.70
22.90
22.10
21.90
21.00
20.90
21.10
20.00
19.50
19.60
18.50
17.70
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
18.50
23.50
24.40
24.60
24.45
23.90
23.65
23.10
22.20
22.80
21.75
21.35
20.80
19.85
19.10
14.00
19.60
16.00
15.60
16.50
15.00
14.00
13.50
13.10
13.70
13.50
12.40
12.00
11.10
10.50
14.00
19.60
16.00
15.60
16.50
15.00
14.00
13.50
13.10
13.70
13.50
12.40
12.00
11.10
10.50
14.00
15.40
13.60
12.60
14.60
13.80
12.80
12.10
11.50
12.70
12.30
11.70
11.00
10.70
10.30
14.00
15.40
13.60
12.60
14.60
13.80
12.80
12.10
11.50
12.70
12.30
11.70
11.00
10.70
10.30
14.00
17.50
14.80
14.10
15.55
14.40
13.40
12.80
12.30
13.20
12.90
12.05
11.50
10.90
10.40
14.00
17.50
14.80
14.10
15.55
14.40
13.40
12.80
12.30
13.20
12.90
12.05
11.50
10.90
10.40
4.89
6.27
6.10
6.01
5.82
5.68
5.52
5.34
5.30
5.50
5.42
5.30
4.53
4.35
4.19
4.89
6.27
6.10
6.01
5.82
5.68
5.52
5.34
5.30
5.50
5.42
5.30
4.53
4.35
4.19
4.78
5.80
5.55
5.33
5.82
5.68
5.49
4.98
4.92
4.86
4.73
4.70
4.12
4.03
3.92
4.78
5.80
5.55
5.33
5.82
5.68
5.49
4.98
4.92
4.86
4.73
4.70
4.12
4.03
3.92
4.89
6.04
5.83
5.67
5.82
5.68
5.51
5.16
5.11
5.18
5.08
5.00
4.33
4.19
4.06
4.89
6.04
5.83
5.67
5.82
5.68
5.51
5.16
5.11
5.18
5.08
5.00
4.33
4.19
4.06
OUTDOOR UNITS
System Name
Heat Recovery
Heat Pump
Function
VRV T-SERIES WATER COOLED CERTIFIED DATA, 208-230V/60HZ/3PH AND 460V/60HZ/3PH
Certified efficiency data in accordance with ANSI/AHRI Standard 1230 2010, “Performance Rating of Variable Refrigerant Flow (VRF) Multi-Split Air Conditioning and Heat Pump Equipment” for the VRV T-Series Water Cooled.
The VRV T-Series Water Cooled has been designed and optimized to meet or exceed the latest minimum efficiency requirements in 10 C.F.R. Part 431 as determined by the U.S. Department of Energy (DOE) and
baseline efficiencies as defined by ASHRAE 90.1 2013. Systems under 65MBH are currently certified to AHRI 210/240. IEER ratings are as defined in ASHRAE 90.1 2013.
DETAILED STANDARD OPERATION RANGES FOR VRV T-SERIES WATER COOLED CONDENSING UNITS
Cooling
Heating
60
60
70
80
Indoor temperature (˚F WB)
80
70
60
60
Range for
operation
50
90
Range for
operation
90
50
Range for
for pull-down
pull-down operation
Range
operation
70
Cooling
Range
100
Range for continuous operation
80
Inlet water temperature (˚F)
90
Range for
operation
Range for warming up operation
70
100
Range for continuous operation
80
110
Heating
Range
Range for continuous operation
90
Range for pull-down operation
100
Cooling & Heating
120
Range
warmingupupoperation
operation
Range for
for warming
110
Inlet water temperature (˚F)
110
Range
operation
Rangefor
for continuous
continuous operation
120
Inlet water temperature (˚F)
120
50
60
70
80
Indoor temperature (˚F DB)
Range for
operation
90
50
50
59
80
(Cooling unit / ˚F WB) 57
(Heating unit / ˚F DB)
77
82
Indoor temperature
See the Engineering Data book for complete application rules and extended geothermal operation ranges
VRV Product Catalog
93
VRV T-Series Water Cooled
Heat Pump or Heat Recovery
208-230V
A modular, energy-efficient and reliable alternative to centralized equipment
Features and Benefits
»» Can be applied to both geothermal and boiler/tower applications
as standard with condenser water inlet temperature as low as
14 °F in heating and 23 °F in cooling is possible
»» 2-9V variable water flow control logic2 as standard to increase
waterside system operational efficiencies
»» Refrigerant cooled inverter technology to deliver consistent
and reliable PCB operations
»» Engineered for easy service with drop-down switch box to
access key components
»» Flexible System design with increased diversity up to 150%1
compared to previous VRV water cooled generation
»» Small condensers can be triple stacked for reduced
installation space and increased usable square footage
»» Larger (than previous models) single-system capacity
and modular concept ensures wider application range for
accommodating floor-by-floor loads of commercial buildings
»» Year round comfort and energy efficiency by
combining VRV and VRT technologies
Model specific, check product specification for details
Refer to installation manual for field settings and other requirements
to activate this feature
1
2
VRV T-SERIES WATER COOLED UNIFIED HEAT PUMP AND HEAT RECOVERY
6 Ton
8 Ton
Name
RWEQ72PCTJ1 RWEQ96TATJU
Model
Combination
OUTDOOR UNITS
Performance
Refrigerant Piping
Connection Ratio
Water Side
(Standard)
Water Side
(Geothermal)
Unit
Electrical
Compressor
Rated Cooling Capacity2
Rated Heating Capacity3
Power
Sound Pressure Level @ 3 ft.
System Configuration: Heat Pump:
HP, Heat Recovery: HR
Liquid Pipe (Main Line)
Suction Gas Pipe (Main Line)
Discharge Gas Pipe (Main Line)
Vertical Pipe Length
(if unit is below FCU)
Actual Pipe Length (Equivalent Length)
Total Pipe Length
Standard Connectable Indoor Unit Ratio
Maximum Number of Indoor Units
BPHE Inlet Pipe (Female Thread)
BPHE Outlet Pipe (Female Thread)
Drain Pipe (Female Thread)
Maximum System Water
Pressure (BPHE)
Standard Inlet Water
Temperature Range Cooling
Standard Inlet Water
Temperature Range Heating
Recommended Inlet Water Flow
Rate per Module (minimum)5
Inlet Water Temperature
Range Cooling6
Inlet Water Temperature
Range Heating6
Water Flow Rate5
Weight
BTU/h
BTU/h
V/ph/Hz
dB(A)
in.
in.
in.
92,000
103,000
50
114,000
129,000
54
55
12 Ton
16 Ton
18 Ton
20 Ton
RWEQ144TATJU RWEQ192TATJU RWEQ216TATJU RWEQ240TATJU
RWEQ96TATJU
2 x RWEQ96TATJU
2 x RWEQ120TATJU
RWEQ120TATJU
138,000
184,000
206,000
228,000
154,000
206,000
232,000
258,000
208-230/3/60
60.5
57
57.5
58
HP
HR
HP
HR
HP
HR
HP
HR
HP
HR
HP
HR
HP
HR
3/8
3/4
N/A
3/8
5/8
3/4
3/8
7/8
N/A
3/8
3/4
7/8
1/2
1-1/8
N/A
1/2
3/4
1-1/8
1/2
1-1/8
N/A
1/2
7/8
1-1/8
5/8
1-1/8
N/A
5/8
1-1/8
1-1/8
5/8
1-1/8
N/A
5/8
1-1/8
1-1/8
5/8
1-3/8
N/A
5/8
1-1/8
1-3/8
ft.
164 (130)
164 (130)
ft.
ft.
%
Qty.
in.
in.
in.
390 (459)
980
50 - 130
12
1-1/4
1-1/4
1/2
540 (623)
980
50 - 150 4
psi
285
16
1-1/4
1-1/4
3/8
20
1-1/4
1-1/4
3/8
25
1-1/4
1-1/4
3/8
50 - 113
°F
50 - 113
gpm
13.2 ~ 39.6
°F
27 - 113
°F
14 - 95
14 - 95
21.2 - 39.6
330
39-3/8 x 30-3/4 x
21-11/16
21.2 - 39.6
in.
Voltage Range (min - max)
Maximum Overcurrent Protection (MOP)
Minimum Circuit Amps (MCA)
Compressor Rated Load Amps (RLA)
Compressor Type
Compressor Set-Up
Compressor Capacity Control
V
A
A
A
%
Some features and benefits may not be available for this model.
Please contact your local Daikin sales representative for more details.
www.daikincomfort.com
37
2 x 1-1/4
2 x 1-1/4
2 x 3/8
41
2 x 1-1/4
2 x 1-1/4
2 x 3/8
2 x 419
419 + 423
2 x 423
23 - 113
gpm
lbs.
Dimensions (H x W x D)
33
2 x 1-1/4
2 x 1-1/4
2 x 3/8
536.6
°F
1
94
64,000
77,000
10 Ton
RWEQ120TATJU
419
423
423
38-9/16 x 30-1/8 x 22-1/16
38-9/16 x (30-1/8 x 2) x 22-1/16
187 - 253
30
22.4
11.6
Daikin G-Type Scroll
35
28.8
19
45
36.5
20.9
23 - 100
16 - 100
1 INV
14 - 100
²Indoor temp.: 80°FDB, 67°FWB/inlet water temp.:
85°F/ Equivalent piping length : 25 ft., level difference : 0 ft.
50
35 + 35
44.6
28.8 + 28.8
29.4
19 + 19
Daikin K-Type Scroll
11 - 100
8 - 100
35 + 45
28.8 + 36.5
19 + 20.9
45 + 45
36.5 + 36.5
20.9 + 20.9
1 INV + 1 INV
8 - 100
7 - 100
Indoor temp.: 70°FDB, 60°FWB/inlet water temp.:
70°F / Equivalent piping length: 25 ft., level difference : 0 ft.
3
RWEQ-TATJU/TAYDU
HP
HR
HP
HR
HP
HR
HP
HR
HP
HR
HP
HR
HP
HR
HP
HR
3/4
1-3/8
N/A
3/4
1-1/8
1-3/8
3/4
1-3/8
N/A
3/4
1-1/8
1-3/8
3/4
1-3/8
N/A
3/4
1-1/8
1-3/8
3/4
1-3/8
N/A
3/4
1-1/8
1-3/8
3/4
1-5/8
N/A
3/4
1-3/8
1-5/8
3/4
1-5/8
N/A
3/4
1-3/8
1-5/8
3/4
1-5/8
N/A
3/4
1-3/8
1-5/8
3/4
1-5/8
N/A
3/4
1-3/8
1-5/8
OUTDOOR UNITS
22 Ton
24 Ton
26 Ton
28 Ton
30 Ton
32 Ton
34 Ton
36 Ton
RWEQ264TATJU RWEQ288TATJU
RWEQ312TATJU
RWEQ336TATJU
RWEQ360TATJU
RWEQ384TATJU
RWEQ408TATJU
RWEQ432TATJU
RWEQ96TATJU
RWEQ120TATJU
2 x RWEQ96TATJU
2 x RWEQ120TATJU RWEQ120TATJU
2 x RWEQ144TATJU
3 x RWEQ120TATJU
3 x RWEQ144TATJU
RWEQ144TATJU
RWEQ120TATJU 2 x RWEQ120TATJU
RWEQ144TATJU 2 x RWEQ144TATJU
252,000
274,000
298,000
320,000
342,000
366,000
388,000
412,000
284,000
308,000
334,000
360,000
386,000
412,000
438,000
462,000
208-230/3/60
61.5
63.5
59
59.5
60
62
64
65
164 (130)
540 (623)
980
50 - 150 4
45
2 x 1-1/4
2 x 1-1/4
2 x 3/8
49
2 x 1-1/4
2 x 1-1/4
2 x 3/8
54
3 x 1-1/4
3 x 1-1/4
3 x 3/8
58
3 x 1-1/4
3 x 1-1/4
3 x 3/8
62
3 x 1-1/4
3 x 1-1/4
3 x 3/8
64
3 x 1-1/4
3 x 1-1/4
3 x 3/8
64
3 x 1-1/4
3 x 1-1/4
3 x 3/8
64
3 x 1-1/4
3 x 1-1/4
3 x 3/8
3 x 423
3 x 423
3 x 423
3 x 423
45 + 50 + 50
36.5 + 44.6 + 44.6
20.9 + 29.4 + 29.4
50 + 50 + 50
44.6 + 44.6 + 44.6
29.4 + 29.4 + 29.4
4 - 100
4 - 100
536.6
50 - 113
50 - 113
13.2 ~ 39.6
23 - 113
14 - 95
21.2 - 39.6
2 x 423
2 x 423
2 x 419 + 423
38-9/16 x (30-1/8 x 2) x 22-1/16
45 + 50
36.5 + 44.6
20.9 + 29.4
50 + 50
44.6 + 44.6
29.4 + 29.4
38-9/16 x (30-1/8 x 3) x 22-1/16
35 + 35 + 45
28.8 + 28.8 + 36.5
19 + 19 + 20.9
1 INV + 1 INV
6 - 100
5 - 100
Varies based on indoor and condensing unit model
selected; refer to Engineering Manual for details.
4
419 + 2 x 423
5 - 100
187 - 253
35 + 45 + 45
45 + 45 + 45
45 + 45 + 50
28.8 + 36.5 + 36.5
36.5 + 36.5 + 36.5
36.5 + 36.5 + 44.6
19 + 20.9 + 20.9
20.9 + 20.9 + 20.9
20.9 + 20.9 + 29.4
Daikin K-Type Scroll
1 INV + 1 INV + 1 INV
5 - 100
5 - 100
4 - 100
Please note that a water strainer (standard accessory for the
T-series, field supplied for the PC-series) is required for each
condensing unit model.
5
Application rules apply below 50°F. Please contact your local
Daikin sales representative for design assistance and approval.
6
VRV Product Catalog
95
VRV T-Series Water Cooled
Heat Pump or Heat Recovery
460V
A modular, energy-efficient and reliable alternative to centralized equipment
Features and Benefits
»» Flexible System design with increased diversity up to 150%1
compared to previous VRV water cooled generation
»» Small condensers can be triple stacked for reduced
installation space and increased usable square footage
»» Larger (than previous models) single-system capacity
and modular concept ensures wider application range for
accommodating floor-by-floor loads of commercial buildings
»» Year round comfort and energy efficiency by
combining VRV and VRT technologies
»» Can be applied to both geothermal and boiler/tower applications
as standard with condenser water inlet temperature as low as
14 °F in heating and 23 °F in cooling is possible
»» 2-9V variable water flow control logic2 as standard to increase
waterside system operational efficiencies
»» Refrigerant cooled inverter technology to deliver consistent
and reliable PCB operations
»» Engineered for easy service with drop-down switch box to
access key components
Model specific, check product specification for details
Refer to installation manual for field settings and other requirements
to activate this feature
1
2
OUTDOOR UNITS
VRV T-SERIES WATER COOLED UNIFIED HEAT PUMP AND HEAT RECOVERY
6 Ton
8 Ton
10 Ton
12 Ton
16 Ton
18 Ton
20 Ton
Name
RWEQ72PCYD1 RWEQ96TAYDU RWEQ120TAYDU RWEQ144TAYDU RWEQ192TAYDU RWEQ216TAYDU RWEQ240TAYDU
Model
RWEQ96TAYDU
Combination
2 x RWEQ96TAYDU
2 x RWEQ120TAYDU
RWEQ120TAYDU
Rated Cooling Capacity²
BTU/h
64,000
92,000
114,000
138,000
184,000
206,000
228,000
Rated Heating Capacity3
BTU/h
77,000
103,000
129,000
154,000
206,000
232,000
258,000
Performance
Power
V/ph/Hz
460/3/60
Sound Pressure Level @ 3 ft.
dB(A)
50
54
55
60.5
57
57.5
58
System Configuration: Heat
HP
HR
HP
HR
HP
HR
HP
HR
HP
HR
HP
HR
HP
HR
Pump: HP, Heat Recovery: HR
Liquid Pipe (Main Line)
in.
3/8
3/8
3/8
3/8
1/2
1/2
1/2
1/2
5/8
5/8
5/8
5/8
5/8
5/8
Suction Gas Pipe (Main Line)
in.
3/4
5/8
7/8
3/4
1-1/8
3/4
1-1/8
7/8
1-1/8
1-1/8
1-1/8
1-1/8
1-3/8
1-1/8
in.
N/A
3/4
N/A
7/8
N/A
1-1/8
N/A
1-1/8
N/A
1-1/8
N/A
1-1/8
N/A
1-3/8
Refrigerant Piping Discharge Gas Pipe (Main Line)
Vertical Pipe Length
ft.
164 (130)
164 (130)
(if unit is below FCU)
Actual Pipe Length (Equivalent Length)
ft.
390 (459)
540 (623)
Total Pipe Length
ft.
980
980
Standard Connectable Indoor Unit Ratio
%
50 - 130
50 - 150 4
Connection
Ratio
Maximum Number of Indoor Units
Qty.
12
16
20
25
33
37
41
in.
1-1/4
1-1/4
1-1/4
1-1/4
2 x 1-1/4
2 x 1-1/4
2 x 1-1/4
BPHE Inlet Pipe (Female Thread)
BPHE Outlet Pipe (Female Thread)
in.
1-1/4
1-1/4
1-1/4
1-1/4
2 x 1-1/4
2 x 1-1/4
2 x 1-1/4
Drain Pipe (Female Thread)
in.
1/2
3/8
3/8
3/8
2 x 3/8
2 x 3/8
2 x 3/8
Maximum System Water
psi
285
536.6
Pressure (BPHE)
Water Side
Standard Inlet Water
(Standard)
°F
50 - 113
Temperature Range Cooling
Standard Inlet Water
°F
50 - 113
Temperature Range Heating
Recommended Inlet Water Flow
gpm
13.2 ~ 39.6
Rate per Module (minimum)5
Inlet Water Temperature
°F
27 - 113
23 - 113
Range Cooling6
Water Side
Inlet Water Temperature
(Geothermal)
°F
14 - 113
14 - 95
Range Heating6
Water Flow Rate5
gpm
21.2 - 39.6
21.2 - 39.6
Weight
lbs.
343
426
430
430
2 x 426
426 + 430
2 x 430
Unit
39-3/8 x 30-3/4 x
Dimensions (H x W x D)
in.
38-9/16 x 30-1/8 x 22-1/16
38-9/16 x (30-1/8 x 2) x 22-1/16
21-11/16
Voltage Range (min - max)
V
414 - 506
Maximum Overcurrent Protection (MOP)
A
15
15
20
25
15 + 15
15 + 20
20 + 20
Electrical
Minimum Circuit Amps (MCA)
A
10.2
13
16.5
20.2
13 + 13
13 + 16.5
16.5 + 16.5
Compressor Rated Load Amps (RLA)
A
5.3
8.6
9.4
13.3
8.6 + 8.6
8.6 + 9.4
9.4 + 9.4
Compressor Type
Daikin G-Type Scroll
Daikin K-Type Scroll
Compressor
Compressor Set-Up
1 INV
1 INV + 1 INV
Compressor Capacity Control
%
23 - 100
16 - 100
14 - 100
11 - 100
8 - 100
8 - 100
7 - 100
1
Some features and benefits may not be available for this model.
Please contact your local Daikin sales representative for more details.
96
www.daikincomfort.com
²Indoor temp.: 80°FDB, 67°FWB/inlet water temp.:
85°F/ Equivalent piping length : 25 ft., level difference : 0 ft.
3
Indoor temp.: 70°FDB, 60°FWB/inlet water temp.:
70°F / Equivalent piping length: 25 ft., level difference : 0 ft.
RWEQ-TATJU/TAYDU
HP
HR
HP
HR
HP
HR
HP
HR
HP
HR
HP
HR
HP
HR
HP
HR
3/4
1-3/8
N/A
3/4
1-1/8
1-3/8
3/4
1-3/8
N/A
3/4
1-1/8
1-3/8
3/4
1-3/8
N/A
3/4
1-1/8
1-3/8
3/4
1-3/8
N/A
3/4
1-1/8
1-3/8
3/4
1-5/8
N/A
3/4
1-3/8
1-5/8
3/4
1-5/8
N/A
3/4
1-3/8
1-5/8
3/4
1-5/8
N/A
3/4
1-3/8
1-5/8
3/4
1-5/8
N/A
3/4
1-3/8
1-5/8
OUTDOOR UNITS
22 Ton
24 Ton
26 Ton
28 Ton
30 Ton
32 Ton
34 Ton
36 Ton
RWEQ264TAYDU RWEQ288TAYDU RWEQ312TAYDU RWEQ336TAYDU RWEQ360TAYDU RWEQ384TAYDU
RWEQ408TAYDU
RWEQ432TAYDU
RWEQ120TAYDU
2 x RWEQ96TAYDU RWEQ96TAYDU
2 x RWEQ120TAYDU RWEQ120TAYDU
2 x RWEQ144TAYDU
3 x RWEQ120TAYDU
3 x RWEQ144TAYDU
RWEQ144TAYDU
RWEQ120TAYDU 2 x RWEQ120TAYDU
RWEQ144TAYDU 2 x RWEQ144TAYDU
252,000
274,000
298,000
320,000
342,000
366,000
388,000
412,000
284,000
308,000
334,000
360,000
386,000
412,000
438,000
462,000
460/3/60
61.5
63.5
59
59.5
60
62
64
65
164 (130)
540 (623)
980
50 - 150 4
45
2 x 1-1/4
2 x 1-1/4
2 x 3/8
49
2 x 1-1/4
2 x 1-1/4
2 x 3/8
54
3 x 1-1/4
3 x 1-1/4
3 x 3/8
58
3 x 1-1/4
3 x 1-1/4
3 x 3/8
62
3 x 1-1/4
3 x 1-1/4
3 x 3/8
64
3 x 1-1/4
3 x 1-1/4
3 x 3/8
64
3 x 1-1/4
3 x 1-1/4
3 x 3/8
64
3 x 1-1/4
3 x 1-1/4
3 x 3/8
3 x 430
3 x 430
3 x 430
20 + 25 + 25
16.5 + 20.2 + 20.2
9.4 + 13.3 + 13.3
25 + 25 + 25
20.2 + 20.2 + 20.2
13.3 + 13.3 + 13.3
4 - 100
4 - 100
536.6
50 - 113
50 - 113
13.2 ~ 39.6
23 - 113
14 - 95
21.2 - 39.6
2 x 430
2 x 430
2 x 426 + 430
38-9/16 x (30-1/8 x 2) x 22-1/16
20 + 25
16.5 + 20.2
9.4 + 13.3
25 + 25
20.2 + 20.2
13.3 + 13.3
15 + 15 + 20
13 + 13 + 16.5
8.6 + 8.6 + 9.4
5 - 100
Varies based on indoor and condensing unit model
selected; refer to Engineering Manual for details.
4
3 x 430
38-9/16 x (30-1/8 x 3) x 22-1/16
1 INV + 1 INV
6 - 100
426 + 2 x 430
5 - 100
414 - 506
15 + 20 + 20
20 + 20 + 20
20 + 20 + 25
13 + 16.5 + 16.5
16.5 + 16.5 + 16.5
16.5 + 16.5 + 20.2
8.6 + 9.4 + 9.4
9.4 + 9.4 + 9.4
9.4 + 9.4 + 13.3
Daikin K-Type Scroll
1 INV + 1 INV + 1 INV
5 - 100
5 - 100
4 - 100
Please note that a water strainer (standard accessory for the
T-series, field supplied for the PC-series) is required for each
condensing unit model.
5
Application rules apply below 50°F. Please contact your local
Daikin sales representative for design assistance and approval.
6
VRV Product Catalog
97
VRV IV S-Series
Heat Pump
208-230V
Light Commercial
The VRV IV S-series system is a highly efficient solution for
small commercial buildings requiring heating and cooling of
up to 9 zones. A mix of ducted and duct-free indoor units
can be combined to provide individual comfort and ease
of installation.
Whether you are working with space constraints or want
to maximize the amount of commercial space available,
the VRV IV S-series system gives you the flexibility
you need. With its simple, versatile design and long
piping (up to 230 ft. actual piping length one way), the
VRV IV S-series can accommodate practically any floor layout,
enabling better use of space.
Retail
OUTDOOR UNITS
Its advanced zoning capabilities allow floor-by-floor installation
so that each floor can be occupied quickly upon completion.
And, because the outdoor units are lightweight and vibration-free,
there’s no need to reinforce floors, reducing both installation time
and costs.
Daikin VRV’s wide range of stylish and discreet indoor units
provide configurations for every retail space, giving you the
benefit of our highly efficient technology, whatever the design
of your store. Wall mounted units matched to your interior
meet both aesthetic and energy needs while also supporting
the look and feel of your brand and preserving floor space.
Slim ducted and concealed units blend almost unseen into
your store, while floor standing units with small footprints
preserve floor space, fitting unobtrusively into recesses or
under windows.
Restaurant
Features and Benefits
»» Single-phase technology is perfect for light commercial
and residential applications in 36,000, 48,000 and
60,000 Btu/h models.
»» Space-saving design to fit in tight areas and
realize quick and easy installation.
»» Savings in energy use due to higher SEER and HSPF
ratings when compared to VRV III-S.
»» Soft sound level operation ensures a comfortable fit
in any room.
»» Single-supplier reliability. The system — factory
engineered and 80% complete upon delivery — is
fully optimized by Daikin, plus has self-diagnostics
and one of the best warranties in the industry*.
»» Simplified equipment selection with a
flexible array of indoor unit options.
* Complete warranty details available from your local Daikin
manufacturer’s representative or distributor or online at
www.daikincomfort.com.
98
www.daikincomfort.com
Apartments/Condos
CERTIFIED PERFORMANCE DATA
Model Number
RXTQ36TAVJ9
RXTQ48TAVJU
RXTQ60TAVJU
Nominal Cooling
Capacity (BTU/h)
36,000
36,000
36,000
48,000
48,000
48,000
57,500
57,500
57,500
Indoor Units Combination
Non-Ducted Indoor Units
Ducted Indoor Units
Mixed Ducted and Non-Ducted Indoor Units
Non-Ducted Indoor Units
Ducted Indoor Units
Mixed Ducted and Non-Ducted Indoor Units
Non-Ducted Indoor Units
Ducted Indoor Units
Mixed Ducted and Non-Ducted Indoor Units
EER 95F
SEER
12.0
10.0
11.0
10.3
9.4
9.85
9.8
9.2
9.5
18.0
16.0
17.0
18.0
16.0
17.0
18.0
16.0
17.0
Nominal Heating
Capacity (BTU/h)
40,000
40,000
40,000
52,000
52,000
52,000
57,500
57,500
57,500
Heating COP
@ 47 °F
4.10
3.30
3.70
4.00
3.35
3.68
4.30
3.70
4.00
Heating COP
@ 17 °F
3.0
2.5
2.8
3.0
2.7
2.9
3.2
2.7
3.0
Low Heating
Capacity (BTU/h)
23,600
22,000
22,800
32,200
32,000
32,100
37,000
34,000
35,500
HSPF
10.3
9.0
9.7
10.0
9.0
9.5
10.5
10.5
10.5
VRV IV-S SERIES
Model Name
RXTQ36TAVJ9
ODU Style
Fan Type
Performance
Connection Ratio
Unit
Fan
Electrical
Compressor
lbs.
in.
in.
ft.
ft.
ft.
ft.
%
Qty
(HxWxD)
lbs.
CFM
kW
A
A
A
Type
%
Single Fan
36,000
40,000
RXTQ60TAVJU
Double Fan
48,000
52,000
23 to 122
-4 to 60
208-230/1/60
57,500
57,500
58
57
R-410A
7.5
3/8
6.4
7.9
5/8
3/4
98
33
164
820
49
230
984
50-130
8
39 x 37 x 12-5/8
176
6
39 x 37 x 12-5/8
172
9
52-15/16 x 35-7/16 x 12-5/8
225
3741
0.070 X 2
2682
0.20 x 1
25
17
15.3
35
29
19.0
Daikin Swing
14-100
23.2
Range for operation
Range for warming up operation
Range for warming up operation
Range for operation
DETAILED OPERATION RANGES FOR VRV IV-S (RXTQ_TAVJU) HEAT PUMP OUTDOOR UNITS
Range for operation
VRV Product Catalog
99
OUTDOOR UNITS
Refrigerant Piping
Single Fan
BTU/h
BTU/h
°F DB
°F WB
V/p/Hz
dB(A)
Nominal Cooling Capacity
Nominal Heating Capacity
Operation Range Cooling
Operation Range Heating
Power
Sound Pressure Level @ 3ft
Refrigerant
Refrigerant Quantity
Liquid Pipe (Main Line)
Suction Gas Pipe (Main Line)
Vertical Pipe Length
Maximum vertical pipe length between IDU
Actual Pipe Length (Equivalent Length)
Total Piping Length
Connectable Indoor Unit Ratio
Number of Indoor Units
Outdoor Unit Size
Weight
Airflow
Fan Motor Output and Quantity
Maximum Over Current Protection (MOP)
Minimum Circuit Amps (MCA)
Rated Load Amps (RLA
Compressor Type
Capacity Control
RXTQ48TAVJU
VRV IV
Installation Space
/
AURORA™
Installation Space Examples
»» The installation space requirement shown in the figure is a
reference for cooling.
»» During installation, install the units using the most
appropriate of the patterns shown in the figure for the
location in question, taking into consideration human traffic
and wind.
»» If the number of units installed is more than that shown in
the pattern in the figure, install the units so that there is no
air short circuiting.
»» Consider the space needed for the refrigerant piping when
installing the units, as determined by local codes.
»» If the space requirements in the figure do not apply, contact
your contractor or Daikin directly.
OUTDOOR UNITS
100
www.daikincomfort.com
/
AURORA™
3. When installing, the units
most appropriate pattern
1. Heights of walls in case of Patterns 1 and 2:
should be selected in order
Front: 59in
to obtain the best fit in the
Suction side: 19-5/8in
space
Section 3available, always
Side: Height unrestricted.
bearing
in mind the need to
Installation space shown in this drawing is based on
leave
enough
space for a
the NOTE:
cooling
operation
atinstalled
95°F than
outdoor
airin temperature.
If more
units are to be
are shown
Section 3, your layout should take account of the possibility of short
circuiting.
person
to
pass
between the
When the design outdoor temperature exceeds 95°F
units
and
wall
and
for the
or the load exceeds maximum ability because of much
air
to
circulate
freely.
generation load of heat in all outdoor unit, take the
Notes
suction-side space more broadly than the space shown
in this drawing.
VRV Product Catalog
OUTDOOR UNITS
2. If the above wall heights are exceeded then h2/2 and
h1/2 should be added to the front and suction side
service spaces respectively as shown in the figure.
4. The units should be installed to leave sufficient
space at the front for the field refrigerant piping
work to be carried out comfortably.
101
VRV III PC, VRV T-Series Water Cooled
& VRV IV S-Series
Installation Space
OUTDOOR UNITS
Notes
1. Heights of walls in case of Patterns
1 and 2:
Front: 59in.
Suction side: 19-5/8in
Side: Height unrestricted.
Installation space shown in above
are based on the cooling operation
at 95°FDB outdoor air temperature.
The suction side space must be
extended in the following case.
-- When the design outdoor
temperature exceeds 95°FDB.
-- When the heat loads are large and
exceed maximum operating loads
for all outdoor units.
102
www.daikincomfort.com
2. When the wall heights exceed
above, add “h2” /2 and “h1” /2
to the front and suction service
spaces respectively. (See right
figure for “h2” and “h1”.)
3. When installing units, the most
appropriate pattern from those
shown above should be selected.
-- a person to pass between the units
and surrounding walls.
-- the air to circulate freely.
-- The possibility of short circuiting
should be evaluated when installing
more units that those shown in the
patterns above.
4. Sufficient space should be provided
in front of the units for refrigerant
piping installation and servicing.
9
5
11-13/16
35-7/16
11-13/16
6
6
11-13/16
11-13/16
11
[4]
5
22-1/16 19-11/16
8
13/16
13/16
OUTDOOR UNITS
13/16
13/16
11-13/16
5
11-13/16
7
7
9
38-9/16
5
9
6
13/16
[3]
30-11/8
21-9/16
8
9
2-15/16
7. Service Space (back side)
8. Space for installing water
piping must be ample
enough
to remove the front panel.
7
2
36-7/16
1
13-3/4
6. Service Space (front side)
13/16
4. Side view
15-15/16 14-3/4
3. Top view
19-11/16
10.Secure spaces in the front, back,
and top sides as same as the
case of single installation.
35-7/16
2. In case of multiple unit installation
[inch.]
5. Condensing unit
11.Service space above the unit
for refrigerant piping (refer to
Engineering Data Book for
further details)
9. Ventilation space (refer to Engineering
Data Book for further details)
11-13/16
1. In case of a single installation [inch.]
3-15/16
9-13/16
10
In case of series installation, some space between the units is
needed for wiring with conduit and servicing.
4(1
00
)o
1.Where there is an obstacle on the suction side:
10 e
4 ( mor
or
(a) No obstacle above
e
or
0)
rm
0
4(1
o
0)
»» Obstacle on the suction side only
»» Obstacle on both sides
4(
10
0
)o
4(1
00
)o
rm
(a) No obstacle above
ore
4(
e
orore
10
0
)o
(1) Stand alone installation
4(1
00
4o
e
or
4
20
or
m
or
re
mo
)o
rm
ore
e
or
)o
rm
00
4(1
4o
rm
)o rm
0 o
10 0)
4 ( (10
rm
ore
4(1
00
)o
rm
ore
rm
e
or
rmo
4 ore
)
00
4(1
or
00
4(1
rm
ore
e
or
m
e
or
rm
)o
4(1
00
)o
4
rm
ore
rm
ore
ore
rm
)o
0
(50
20
Unit values are in inches
VRV Product Catalog
ore
4(1
00
)o
(1) Stand alone installation
2.Where there is an obstacle on the discharge side:
rm
103
r
VRV IV & VRV AURORA™, VRV III PC,
VRV T-Series Water Cooled
& VRV IV-S
Piping Length
The long piping length provides more design flexibility, which can match even large-sized buildings.
Air-cooled system piping length
For connection of only VRV indoor units
VRV III PC, VRV IV &
VRV AURORA
VRV IV-S
Max. actual piping length
541 ft.
(3-Ton: 164 ft.)
Max. equivalent
piping length
623 ft.
(3-Ton: 213 ft.)
Max. total piping length
OUTDOOR UNITS
Max. level difference
between the outdoor units
and the indoor units
3281 ft.
(AURORA: 1640 ft.)
230 ft.
Single use
295 ft.
984 ft.
a
(3-Ton: 820 ft.)
c
b
g
f
295 ft.
†
e
d
h
i
98 ft.
r
Max. 98 ft.
s
49 ft.
Max. level difference
between the indoor units
100 ft.
(3-Ton: 33 ft.)
Max. distance from 1st
refrigerant branch joint
295 ft.
130 ft.
Max. 49 ft.+
Piping for VRV IV, VRV AURORA, VRV III PC and VRV IV-S
ACTUAL PIPING LENGTH
VRV III PC / VRV IV / VRV AURORA
VRV IV-S
Refrigerant piping length
Total piping length
Maximum allowable
Between the first indoor unit
piping length
branch and the farthest
indoor unit
541 ft.
3281 ft. AURORA: 1640 ft.
3-Ton
164 ft.
820 ft.
295 ft.*
98 ft.
EXAMPLE
EQUIVALENT PIPING LENGTH
VRV III PC / VRV IV
VRV IV-S
4-5 Ton
230 ft.
a+b+c+d+e
984 ft. a+b+c+d+e+f+g+h+i
98 ft.
Maximum allowable
level difference
16 ft.
98 ft.
295 ft.†
295 ft.
3-Ton
213 ft
–
4-5 Ton
295 ft
–
–
–
–
b+c+d+e
LEVEL DIFFERENCE
VRV III PC / VRV IV / VRV AURORA
Between the outdoor units (multiple use on the same circuit)
Between the indoor units
If the outdoor unit is above
Between the outdoor units and
the indoor units
If the outdoor unit is below
623 ft. / 295 ft
–
EXAMPLE
VRV IV-S
3-Ton
n/a
33
98
98
4-5 Ton
n/a
49
98
98
No special requirements up to 131 ft. The maximum actual piping length can be 295 ft., depending on conditions. Various conditions and requirements have to be met
to allow utilization of 295 ft. piping length. Be sure to refer to the Engineering Data Book for details of these conditions and requirements.
†
When level differences are 164 ft. or more, the diameter of the main liquid piping size must be increased and connection ratio must be 80% to 130%.
If the outdoor unit is above the indoor unit, a dedicated setting on the outdoor unit is required. Refer to the Engineering Data Book and contact your
local dealer for more information.
◆
100 ft. is supported for VRV IV / VRV AURORA. For VRV-III PC, the limit is 49 ft.
*
104
www.daikincomfort.com
—
s
r
r
Water-cooled system piping length
Water cooled systems provide considerable design flexibility
with total piping lengths of up to 980 ft. and vertical separation of
up to 164 ft.* between condensing units and indoor units.
For connection of only VRV indoor units
Actual piping length between the VRV T-Series and
indoor units: 540ft. (equivalent piping length: 623ft.)
Water piping
Refrigerant piping
Level difference between
indoor units: 98 ft.
LIMITATIONS
540 (623)
980
164 (130)
98
130 (295)**
* Conditions apply when the condenser is lower than indoor units. Refer to your local Daikin
representative for further information.
** Conditions/rules apply. Refer to Installation manual for further details.
Indoor installation of condensing unit
Water piping length depends on the heat source equipment
VRV Product Catalog
105
OUTDOOR UNITS
Level difference between the
VRV T-Series Water Cooled and indoor units:
164 ft. if the condensing unit is above
130 ft. if the condensing unit is below
REFRIGERANT PIPING LIMITATIONS
Linear piping between condensing unit and furthest
located fan coil unit (equivalent), ft.
Total “one-way” piping in the complete piping network, ft.
Vertical (height) separation between the condensing unit
and the fan coil units (if condensing unit is below)*, ft.
Vertical (height) separation between fan coil units, ft.
Linear piping between 1st REFNET and furthest located
fan coil unit, ft.
VRV Accessories
Branch Selector
Boxes
Branch Selector Boxes for Heat Recovery Systems
Providing flexibility and minimizing mechanical and electrical
installation costs, Daikin's branch selector boxes are ideal
for spaces that require individual heating and cooling control.
»» Extended range of product offerings with 1, 4, 6, 8, 10
and 12 port options
»» No drain or condensate consideration required
»» Unlimited number of unused ports per
BSQ36TVJ, BSQ60TVJ,
& BSQ96TVJ Single Port
box or system
»» Reduced electrical and mechanical
BS4Q54TVJ
installation costs
»» Ultimate flexibility – Choose multi-port or
single-port styles to customize your design
»» Up to 72% reduction in footprint, as compared to
OUTDOOR UNITS
previous generation models
BS6Q54TVJ
»» Up to 17% lower sound levels compared to
current VRV III models
»» Up to 65% reduction in weight, as compared to
previous generation models
BS10Q54TVJ
Branch Selector Boxes Compatibility
Single-Port and Multi-Port Branch Selector Boxes BS-TVJ
Series are compatible with VRV IV, VRV T-Series Water Cooled
and VRV III REYQ-PC Series.
Daikin's branch selector boxes are ideal for spaces that require individual
heating and cooling control.
106
www.daikincomfort.com
TECHNICAL DATA FOR MULTI-PORT BRANCH SELECTOR BOXES
Model
BS4Q54TVJ
Number of branches
4
Maximum capacity index per branch
Maximum total capacity index
144
Maximum connectable indoor units per branch
Liquid
in.
IU
Gas
in.
Connecting
Liquid
in.
Ø3/8
Pipes
IU
Suction Gas
in.
Ø7/8
HP/LP Gas
in.
ph/V/Hz
Power Supply
Electrical Maximum Overcurrent Protection, MOP
A
Minimum Circuit Amps, MCA
A
Mass (Weight)
lbs.
49
Dimensions (H x W x D)
in.
11-3/4 x 14-9/16 x 18-15/16
BS6Q54TVJ
6
BS8Q54TVJ
8
54
BS10Q54TVJ
10
216
BS12Q54TVJ
12
290
5
Ø1/4, Ø3/8
Ø1/2, Ø5/8
Ø1/2
Ø5/8
Ø1-1/8
Ø3/4
Ø1-1/8
1/208-230/60
15
0.6
0.8
68
73
11-3/4 x 22-13/16 x 18-15/16
1
1.2
101
106
11-3/4 x 32-5/16 x 18-15/16
MULTI-PORT BRANCH SELECTOR BOX INSTALLATION SPACE
Field Specific
Minimum
Clearance
(B)
(A)
MINIMUM CLEARANCE
A
in.
B
in.
BSQ36TVJ
1
36
4
BS6Q54TVJ
BS8Q54TVJ
20
11-3/4
BS10Q54TVJ
BSQ60TVJ
1
60
8
Ø3/8
BS12Q54TVJ
OUTDOOR UNITS
TECHNICAL DATA FOR SINGLE-PORT BRANCH SELECTOR BOXES
Model
Number of branches
Maximum capacity index
Maximum connectable indoor units
Liquid
in.
IU
Gas
in.
Connecting
Liquid
in.
Pipes
IU
Suction Gas
in.
HP/LP Gas
in.
Power Supply
ph/V/Hz
Maximum Overcurrent Protection, MOP
A
Electrical
Minimum Circuit Amps, MCA
A
Mass (Weight)
lbs.
Dimensions (H x W x D)
in.
BS4Q54TVJ
BSQ96TVJ
1
96
8
Ø5/8
Ø7/8
Ø3/8
Ø5/8
Ø1/2
Ø7/8
Ø3/4
1/208-230/60
15
0.1
27
8-1/8 x 15-1/4 x 12-13/16
27
33
SINGLE-PORT BRANCH SELECTOR BOX INSTALLATION SPACE
(B)
(C)
(D)
(A)
(E)
MINIMUM CLEARANCE
A
in.
B
in.
C
in.
D
in.
E
in.
BSQ36TVJ
10
10
12
12
BSQ60TVJ
10
10
13-3/4
13-3/4
12
BSQ96TVJ
12
12
15-3/4
15-3/4
11-13/16
For additional technical information and all equipment installation and application limitations please refer to the specific Engineering Data Books.
VRV Product Catalog
107
VRV Accessories
REFNET
Pipe Joints
REFNET
REFNET joints distribute correct flow of refrigerant
in every branch of the piping network.
REFNET Joint
VRV IV Heat Pump
OPTIONAL ACCESSORIES
REFNET header
RXYQ72T
RXYQ96T
RXYQ120T
RXYQ144T
RXYQ168T
KHRP26M22H (max. 4 branch)
KHRP26M33H (max. 8 branch)
KHRP26M22H (max. 4 branch)
KHRP26M33H (max. 8 branch)
KHRP26M72H (max. 8 branch)
KHRP26A22T
KHRP26A33T
KHRP26A22T
KHRP26A33T
KHRP26M72TU
Distributed piping
joint
OUTDOOR UNITS
Outdoor unit multi connection piping kit
—
REFNET Header
RXYQ192T
RXYQ216T
RXYQ240T
RXYQ360T
RXYQ264T
RXYQ384T
RXYQ288T
RXYQ408T
RXYQ312T
RXYQ336T
KHRP26M22H (max. 4 branch)
KHRP26M33H (max. 8 branch)
KHRP26M72H (max. 8 branch)
KHRP26M73H (max. 8 branch)
KHRP26A22T
KHRP26A33T
KHRP26M72TU
KHRP26M73TU
BHFP22P100U
BHFP22P151U
VRV IV Heat Recovery / VRV AURORA™ Heat Recovery
REYQ72T
REYQ96T
OPTIONAL ACCESSORIES
REFNET header
REYQ120T
REYQ144T
REYQ168T
RELQ72T
RELQ96T
RELQ120T
KHRP25M33H9 (max. 8 branch)
KHRP25M33H9 (max. 8 branch)
KHRP25M72H9 (max. 8 branch)
KHRP25A22T9
KHRP25A33T9
KHRP25A22T9
KHRP25A33T9
KHRP25M72TU9
Distributed piping
REFNET joint
Outdoor unit multi connection piping kit
—
REYQ192T
REYQ216T
REYQ240T
REYQ264T
REYQ288T
REYQ312T
REYQ336T
RELQ144T
RELQ192T
RELQ240T
REYQ360T
REYQ384T
REYQ408T
REYQ432T
REYQ456T
KHRP25M33H9 (max. 8 branch)
KHRP25M72H9 (max. 8 branch)
KHRP25M73H9 (max. 8 branch)
KHRP25A22T9
KHRP25A33T9
KHRP25M72TU9
KHRP25M73TU9
BHFP26P100U
BHFP26P151U
VRV III PC Heat Recovery
OPTIONAL ACCESSORIES
REYQ72PC
REFNET header
Distributed piping
REFNET joint
108
www.daikincomfort.com
KHRP25M33H9 (max. 8 branch)
KHRP25A22T9
KHRP25A33T9
REYQ96PC
REYQ120PC
REYQ144PCTJ
KHRP25M33H9 (max. 8 branch)
KHRP25M72H9 (max. 8 branch)
KHRP25A22T9
KHRP25A33T9
KHRP25M72TU9
VRV Accessories
REFNET Pipe Joints &
Hail Guard Kit for VRV IV
VRV T-Series Water Cooled Heat Pump / Heat Recovery and VRV-IV-S
UNIT MODEL
NUMBER
REFNET
Header
REFNET
Joint
RWEQ96TATJU
RWEQ96TAYDU
VRV T-SERIES WATER COOLED
RWEQ192,216,240,
RWEQ120TATJU
RWEQ144TATJU
264,288TATJU
RWEQ120TAYDU
RWEQ144TAYDU
RWEQ192,216,240,
264,288TAYDU
VRV-IV-S
RXTQ36TAVJ9
RXTQ48TAVJU
RXTQ60TAVJU
RWEQ312,336,360TATJU
RWEQ312,336,360TAYDU
Heat
Pump
KHRP26M22HR (Max 4 branch)
KHRP26M33H9 (Max 8 branch)
KHRP26M22H9 (Max 4 branch),
KHRP26M33H9 (Max 8 branch)
KHRP26M72H9 (Max 8 branch)
KHRP26M22H9 (Max 4 branch), KHRP26M33H9 (Max 8 branch)
KHRP26M72H9 (Max 8 branch), KHRP26M73HU9 (Max 8 branch)
KHRP26M22H9 (Max. 4 branch)
KHRP26M33H9 (Max. 8 branch
Heat
Recovery
KHRP26M33H9 (Max 8 branch)
KHRP25M33H9 (Max 8 branch)
KHRP25M72H9 (Max 8 branch)
KHRP25M33H9 (Max 8 branch), KHRP25M72H9 (Max 8 branch)
KHRP25M73HU9 (Max 8 branch)
__
Heat
Pump
KHRP26A22T9, KHRP26A33T9
KHRP26A22T9, KHRP26A33T9, KHRP26M72TU9
KHRP26A22T9, KHRP26A33T9, KHRP26A72UT9, KHRP26M73TU9
KHRP26A22T9
Heat
Recovery
KHRP25A22T9, KHRP25A33T9
KHRP25A22T9, KHRP25A33T9, KHRP25M72TU9
KHRP25A22T9, KHRP25A33T9, KHRP25A72TU9, KHRP25M73TU9
__
__
BHFP22T84U
BHFP22T126U
__
__
BHFP26T84U
BHFP26T126U
__
Hail Guard Kit for VRV IV
The optional hail guard kit for VRV IV enables optimal airflow for efficient heat transfer while providing condenser coil protection
from hail damage in severe climates. Each hail guard kit, that is field installed, consists of 4 panels (Right, Left, Front and Back).
KIT PART NUMBER
VRV4HGS-K1
VRV4HGL-K1
R_YQ72T
1
QTY OF KITS PER VRV IV OU MODEL
R_YQ96-168T R_YQ192T R_YQ216-336T R_YQ360-456T
1
1
1
2
3
Right Panel
457/8" x 26" x 4"
PANEL DIMENSIONS (H X W X D)
Left Panel
Front Panel
457/8" x 131/4" x 4"
457/8" x 127/8" x 4"
457/8" x 24" x 4"
Front Panel
457/8" x 325/8" x 4"
457/8" x 44 3/4" x 4"
Service space requirements for the front, back and sides
of the condensing unit must be at least 4" greater than the
service space requirements provided in the condensing unit
installation manual and engineering guide.
If the condensing units in multiple unit installations are
installed between 0.75" and 3" maximum between units,
the side hail guard panels between modules may not be
required. For further separation between the modules, full
kits for each module may be required.
Daikin VRV IV provides a solution
for large commercial applications
desiring heating or cooling.
VRV Product Catalog
109
OUTDOOR UNITS
Heat
Outdoor
Pump
Unit Multi
Piping
Heat
Connection
Recovery
Kit
Air Handling Kit
(AHU) Integration Kit
Designed for High Efficiency
The Daikin Air Handling Unit Integration Kit enables a non-VRV
Air Handling Unit to be fully integrated into a Daikin VRV
system, allowing the benefits of inverter technology to extend
to custom terminal units and air handling equipment.
Designed for high system efficiency, the Air Handling Unit
Integration Kit offers a seamless integration and optimized
design flexibility for Air Handling Units while keeping total
installation and commissioning time to a minimum.
Control Box
EKEQMCBAV3-US
EKEQFCBAV3-US
A kit consists of one Control Box and one EEV Box. Two different
control methods can be used for an evaporator coil of up to
16 tons.
Non-VRV
Air Handling
Unit
Electronic Expansion
Valve Box EKEXV_-US
VRV Outdoor
Unit
Features and Benefits
OUTDOOR UNITS
»» Enables non-VRV Air Handling Units to be
seamlessly integrated into a Daikin VRV system
»» Integrates to VRV Heat Pump and
Heat Recovery systems*
Control Box
EEV Box
»» Daikin DIII-NET communication compatible —
can be used with both Daikin iTM and NAV controller
»» Separate Control Box and EEV Box
accommodates flexible installation
»» Available with two control methods:
–– EKEQMCBAV3-US (Z-Control)
–– Standard VRV indoor unit room temperature control
–– EKEQFCBAV3-US (W-Control)
–– Field supplied temperature sensor
–– Field supplied DDC controller with 0-10V capability)
Indoor units
* Important! For any VRV systems that utilize the AHU integration
kits to perform as intended, the DX coil(s) in the non-VRV AHU
unit(s) must meet the range of criteria set forth in the AHU
Integration Kit Selection Guide and all associated piping and
combination rules (refer to IOD-7041A and IOD-7042A), and
should be installed in accordance to the installation manual
provided with the EKEQ control boxes.
110
www.daikincomfort.com
ELECTRONIC
EXPANSION
VALVE BOX
SPECIFICATIONS
Nominal Capacity BTU/h
EKEXV50-US
EKEXV63-US
EKEXV80-US EKEXV100-US EKEXV125-US EKEXV140-US EKEXV200-US EKEXV250-US EKEXV400-US EKEXV500-US
18,000
24,000
30,000
36,000
48,000
60,000
72,000
96,000
144,000
192,000
AHU Heat
Exchanger
Cooling Capacity
Range
BTU/h
17,000-21,000
21,500-26,500
27,000-34,500
34,000-42,000
42,500-52,500
53,000-60,000
60,500-84,000
84,500-105,000 120,000-169,000 170,000-210,000
AHU Heat
Exchanger
Heating
Capacity Range
BTU/h
19,000-24,000
24,200-30,000
30,500-38,000
38,500-47,000
47,500-59,000
59,500-67,500
68,000-94,500
95,000-118,500 136,000-187,500 188,000-236,500
AHU Heat
Exchanger
in3
46-100
101-126
127-161
162-201
202-251
252-281
282-402
403-503
564-804
806-1006
Refrigerant
Volume Range
Power Supply
V/ph/Hz
208-230/1/60
Weight
lbs.
6.4
Height
in.
15-3/4
Width
in.
8-1/2
Depth
in.
3-1/16
Pipe Connections
in.
1/2 x 1/4
3/8 x 5/8
3/4 x 3/8
7/8 x 3/8
1-1/8 x 1/2
1-1/8 x 5/8
*Important! For any VRV systems that utilize the AHU integration kits to perform as intended, the DX coil(s) in the non-VRV AHU unit(s) must meet the range of criteria set forth in the AHU Integration
Kit Selection Guide and all associated piping and combination rules (refer to IOD-7041A and IOD-7042A), and should be installed in accordance to the installation manual provided with the
EKEQ control boxes.
Features and Benefits
»» Designed for both indoor and outdoor installation
»» Equipped with refrigerant filters on both sides of
the expansion valve
OUTDOOR UNITS
»» Can be mounted up to 16 ft (5m) away from the
air handling unit
»» Simplified installation with inlet and
outlet brazed connections
»» Wide range that covers from 1.5 ton to 16 ton
»» Same EEVs as used in standard VRV Indoor
product to deliver precise refrigerant control
VRV Product Catalog
111
Control Box
EKE_CBAV3-US
EKEQMCBAV3 - US
For use with both Daikin VRV indoor
units and custom air handling units
VRV
Indoor
Unit
»» Allows for discharge air control
»» Seamless integration of non-VRV air handling
units with VRV IV HP and HR systems
»» Enables control of the AHU as a VRV Indoor unit
when integrated with a Daikin remote control
»» Connect other VRV indoor units along with
the AHU to the condensing units
»» Provides remote ON/OFF option when
integrated with optional KRP4A71 board
»» Designed for both indoor and
outdoor installations
VRV
Outdoor
Unit
Expansion Valve Kit
EKEXV
Air Handling Unit
Refrigerant Piping
F1, F2 Communication
Communication
Cable
OUTDOOR UNITS
EKEQMCB
EKEQFCBAV3 - US
For use with custom air handling
units only
BRC1E73
»» Seamlessly integrate non-VRV air
handling units with VRV IV HP
»» Best suited for applications where 1 AHU is
connected to 1 VRV system only
»» Connect up to 3 integration kits per VRV
system to serve a large capacity AHU
»» Unified cooling and heating mode programming
»» Enables control of AHU unit using field temperature
sensor and 0-10V field supplied DDC controller
»» Allows for discharge air temperature control
Refrigerant
Piping
Expansion Valve Kit
EKEXV
VRV
Outdoor
Unit
F1, F2
Communication
EKEQFCB
DDC Controller
(Field Supplied) W-Control
112
www.daikincomfort.com
Air Handling Unit
Control Box
EKE_CBAV3-US (cont.)
Entering Air Temperature
Limits
Power Supply
Weight
Height
Width
Depth
Connection Ratio
Cooling °F
Heating °F
V/ph/Hz
lbs.
in.
in.
in.
EKEXV to AHU
Max Piping Distance
VRV IDU + AHU
AHU Only
ODU to AHU
EKEQMCBAV3-US
(Z-Control)
EKEQFCBAV3-US
(W-Control)
57 WB - 77 WB
50 DB - 80 DB
208-230/1/60
8
95 DB/77 WB
Min. of 50 DB
8.6
5-13/64
15-3/4
9-3/8
VRV IV HP (RXYQ_TATJU/TAYDU)
VRV IV HR (REYQ_TATJU/TAYDU)
VRV T-Series Water Cooled (RWEQ_TATJU/TAYDU)
VRV III PC (REYQ_PCTJ/PCYD)
VRV IV S (RXTQ_TAVJU(9)
EKEQMCBAV3-US EKEQFCBAV3-US
(Z-Control)
(W-Control)
■
■
■
Not available
■
■
Not available
Not available
Not available
Heat pump configuration only
50 - 110%
16 ft.
90 - 110%
16ft.
Standard VRV outdoor unit
piping limitations based on
model selection apply
164 ft
Max number of IDU/system
64
32
COMPATIBILITY MATRIX
Not available
1
VRV Product Catalog
113
OUTDOOR UNITS
CONTROL BOX SPECIFICATIONS
114
www.daikincomfort.com
Ventilation
VRV Product Catalog
115
Air Treatment Systems
Daikin’s air treatment systems — creating a better air quality environment.
VENTILATION
Daikin’s Outside Air Processing Unit can be integrated
with a VRV system to provide outside air treatment and air
conditioning in a single system to meet code requirements.
It adjusts the temperature of air from outdoors using a fixed
discharge temperature control reducing air conditioning load.
116
www.daikincomfort.com
In addition to Outside Air Processing Units, we also offer
Energy Heat Recovery units. The Energy Heat Recovery
VAM-GVJU series units combines compactness, energy
conservation, and extensive operation range of outdoor
temperatures. This series provides higher enthalpy
efficiency, due to the greatly enhanced performance
of the thin heat exchanging element. Furthermore,
improved external static pressure offers more flexibility
for installation.
VENTILATION
VRV Refrigerant Piping
VRV Control Wiring
High Efficiency Filter (MERV 8 and MERV 13)
Ventilation System
Power Supply
Airflow Rate
OUTSIDE AIR PROCESSING UNIT, FXMQ-MFVJU
ENERGY RECOVERY VENTILATOR, VAM-GVJU
Connectable
Not connectable
Connectable
Option
Air supply
V/ph/Hz
CFM
Not available
Air supply and Air exhaust
208-230/1/60
635
988
1236
VRV Product Catalog
300/300/170
470/470/390
600/600/500
1200/1200/930
117
FXMQ-MFVJU
100% Outside Air
Processing Unit
Outside Air
Integration Possible
Filter
Included
Concealed, Powerful, Compact,
Quiet, Fresh Air Quality
This unit provides a zoned, decentralized approach to
conditioning outside air. This helps to reduce ductwork and
installation time while increasing efficiency and flexibility.
Both outside air treatment and space conditioning can be
provided from one compact, flexible and efficient VRV system.
VRV indoor units and outdoor air processing unit can be
connected to the same refrigerant line, enabling enhanced
design flexibility.
Layout example
Outside air processing unit
VRV outdoor unit
for outside air supply
Features and Benefits
»» Available in three capacities, nominal 48, 72 and 96 MBH
VRV indoor unit
»» The nominal airflow rates are 635, 988, and
1,236 CFM respectively
for air-conditioning
»» External static pressure capabilities of up to 1.03" W.G.
allows for flexibility with duct work and filtration choices
»» The indoor unit is controlled to a set cooling and heating
discharge air temperature allowing the flexibility to
integrate with a standard Daikin indoor unit or duct
directly to the space
VENTILATION
»» A low profile design of only 18.5" high reduces the required
installation space and can eliminate mechanical rooms or
additional structural supports associated with traditional
OA systems
»» Indoor Air Quality options include MERV 8 and 13 filters
and filter boxes
»» Can be connected to all North American Daikin
VRV systems
»» Connects directly and seamlessly into the Daikin local
and centralized controllers
Operational Characteristics
When the suction air temperature is between 66°F and 109°F,
the Outside Air Processing Unit operates in cooling, and
when between 23°F and 59°F, it operates in heating. The OA
processing unit will work in energy saving fan only between
59°F and 66°F.
118
www.daikincomfort.com
Applications
»» Hotel/conference
centers
»» Schools
»» Retail shopping
centers
»» Large open- plan
offices
»» Churches
FXMQ-MFVJU SPECIFICATIONS
Model Name
Power Supply
Rated Cooling Capacity
Rated Heating Capacity
Airflow Rate
Weight
Height
Width
Depth
Sound Pressure
External Static Pressure
Gas
Pipe Connections
Liquid
4 TON
FXMQ48MFVJU
V/ph/Hz
BTU/h
BTU/h
CFM
lbs.
in.
in.
in.
dB(A)
in. W.G.
in.
in.
6 TON
FXMQ72MFVJU
208-230/1/60
72,000
47,000
988
48,000
30,000
635
190
271
29-1/4
54-3/8
43-5/16
42
0.88
5/8
47
0.96
3/4
3/8
Fuse
Fan Motor Thermal Protector
Galvanized Steel Plate
66 DB/59 WB - 109 DB/90 WB
23 DB to 59 DB
55-77
64-86
°F
°F
°F
°F
Nominal Conditions:
96,000
59,000
1,236
18-1/2
Protection Devices
External Finish
Operating Range - Cooling
Operating Range - Heating
Discharge Air Temp. - Cooling
Discharge Air Temp. - Heating
8 TON
FXMQ96MFVJU
Cooling Mode
Discharge Set Temperature: 64 °F DB
Outdoor: 91 °F DB, 82 °F WB (68% RH)
Pipe Length: 25 ft.
Level Difference: 0 ft.
FXMQ-MFVJU ACCESSORIES
Model Name
Navigation Remote Controller
Wireless Remote Controller
Remote Sensor Kit
Wiring Adapter PCB (interface with aux/primary heater, humidifier, OA damper/fan)
Group Control Adapter PCB (connects to external BMS)
High Efficiency Filter Kit (MERV 13)
High Efficiency Filter Kit (MERV 8)
Heating Mode
Discharge Set Temperature: 77 °F DB
Outdoor: 32 °F DB, 27 °F WB (50% RH)
Pipe Length: 25 ft.
Level Difference: 0 ft.
FXMQ48MFVJU
DACA-MQ48F131K
DACA-MQ48F-8-1K
1.03
7/8
Note: Specifications are subject to change
without notice.
FXMQ72MFVJU
FXMQ96MFVJU
BRC1E73
BRC4C82
KRCS01-1B
KRP1C74
KRP4A71
DACA-MQ96F131K
DACA-MQ96F-8-1K
FXMQ-MFVJU INSTALLATION SPACE
Suction Side
Discharge Side
Ceiling
2.5"
or more
VENTILATION
2.5"
or more
25-9/16"
or more
Ceiling
VRV Product Catalog
119
VAM-GVJU
Outside Air
Integration Possible
Energy Recovery
Ventilator
Energy Efficient, Logical, Compact
This Energy Recovery Ventilator is designed to maintain good
indoor air quality by providing sufficient levels of outside
air and recover waste heat from exhaust air leaving the
conditioned zone. It is also fully compatible with Daikin’s
DIII-NET communications.
Features and Benefits
»» Provides energy saving heat recovery ventilation via
a heat exchanger with temperature and enthalpy
recovery efficiency
Layout example
Energy Recovery Ventilator
»» 0-4% return cross leakage rating
for outside air supply
»» Superior performance with a high efficiency fan and
the capability for use in a wide range of climates
VRV indoor unit
for air-conditioning
»» (5 to 122° FDB and 80% RH or less)
»» Unique functions such as independent operation, third
party equipment interlocking and automatic night purge
to reduce cooling loads and increase energy savings
»» Interlocked simultaneous operation with VRV indoor units
»» Pre-cooling/heating control function to delay the start
of ventilation during air conditioner
start-up for higher energy savings
VENTILATION
»» Supply and exhaust fresh-up operation modes
to help control pressure within a space
VRV outdoor unit
»» Filter sign and display reset notifies when filter changes
are required
»» Temperature recovery efficiency up to 74%
»» Enthalpy recovery efficiency up to 65%
Applications
»» ESP as high as 0.76" W.G.
»» Sound levels as low as 25.5 dB(A) for sound
sensitive installation locations
Heat exchanger with high temperature and enthalpy efficiency
RA
EA
(Return air
from room)
(Exhaust to
outdoors)
SA
OA
(Supply air
to room)
(Air from
outdoors)
120
www.daikincomfort.com
»» Hotel/conference
centers
»» Schools
»» Retail shopping
centers
»» Large open- plan
offices
»» Churches
VAM SPECIFICATIONS
Model Name
Temperature Recovery
Efficiency Percentage
Enthalpy Recovery
Efficiency Percentage
Airflow
Cooling
Heating
Cooling
Heating
100
75
100
75
100
75
100
75
Power Supply
Airflow Rate (H/M/L)
Heat Exchange Mode
Bypass Mode
Weight
Height
Width
Depth
Sound Pressure (H/M/L)
External Static Pressure (H/M/L)
External Finish
Insulation Material
Connection Duct Diameter
Ambient Conditions
%
%
%
%
%
%
%
%
V/ph/Hz
CFM
lbs.
in.
in.
in.
dB(A)
in. W.G.
VAM300GVJU
65
70
65
VAM470GVJU
68
72
66
VAM600GVJU
69
40
48
57
63
45
50
59
65
300/300/170
300/300/170
71
12-1/16
34-5/8
31-1/2
37/33.5/25.5
0.64/0.26/0.16
470/470/390
470/470/390
121
15-1/4
VAM1200GVJU
72
74
70
73
49
52
60
63
208-230/1/60
in.
A
600/600/500
600/600/500
148
15-1/4
43-11/16
32-3/4
42/38.5/35
42.5/39/36
0.73/0.39/0.33
0.76/0.34/0.32
Galvanized Steel Plate
Self-Extinguishing Urethane Foam
10
5°F ~ 122°FDB 80% RH or less
8
1,200/1,200/930
1,200/1,200/930
346
30-7/8
63-3/4
47-13/16
44.5/41.5/38.5
0.56/0.24/0.16
14
21" or more
VAM-GVJU INSTALLATION EXAMPLE
26" or more
(Service space)
Energy Recovery
Ventilator
(Top View)
44" or more
VENTILATION
(Service space)
VRV Product Catalog
121
DVS Dedicated Outside
Air System Air Handling Unit
Outdoor-Mounted AHU
Seamless Integration with VRV Systems
Daikin DVS Dedicated Outside Air System (DVS - DOAS
AHU) is designed for seamless integration with VRV air
cooled heat recovery outdoor units and controls to provide
conditioning of 100%outside ventilation air.
Models, with nominal 1,000, 2,000 and 3,000 CFM air
flow rates, can be configured with pre-treatment, cooling,
reheat and heating components to be applied to a wide
variety of commercial applications desiring the advanced
features that VRV offers.
Features and Benefits
»» Designed to condition outside air so the comfort system
can operate to meet the internal loads while the DVS
DOAS AHU’s for VRV Systems conditions the outside
air and can also deliver neutral air to the space
»» Energy Recovery Wheel section can reduce
the mechanical cooling capacity of the system
compared to a system without the ERW section
»» Auxiliary heat available in modulating gas heat,
SCR controlled electric heat or hot water
»» DVS DOAS AHU’s can be integrated into the
same intelligent Touch Manager (iTM) as the
comfort cooling and heating VRV system
VENTILATION
»» Piping connections between the DVS DOAS AHU’s
and the VRV outdoor units can be made outside
»» Air flow ranges from 670 to 4,000 cfm
allow for flexibility in design
DVS DEDICATED OUTSIDE AIR
Model Name
Nominal Air Flow
Nominal (Minimum-Maximum)
Nominal Cooling Capacity
Dimensions1 * (L xW x H)
Weight1
Electrical
Refrigerant
Auxiliary heater
CFM
BTU/h
in.
lbs.
Gas furnace
Electric heater (kW)
Type
MBH
kW
DVSV05 with ERW
DVSV10 with ERW
DVSV12 with ERW
1,000
(670 - 1,350)
2,000
(1,600 - 2,650)
3,000
(2,000 - 4,000)
41,000
73,000
127,000
103 x 71 x 41
133 x 75 x 57
1,287
2,266
2,371
3-Phase 208V, 3-phase 230V or 3-Phase 460V
R410A
80 / 120 / 160
200 / 300 / 400
200 / 300 / 400
6 / 12 / 18 / 30
30 / 6 / 54
36 / 54 / 72
Weights, dimensions and performance of units are subject to change and will vary based on the components and options that are applied for specific applications.
Nominal conditions: Entering air temperature 95°F DBT / 78°F WBT; 55°F leaving air temperature DX coil; 70°F discharge air temperature.
1
122
www.daikincomfort.com
Controls
VRV Product Catalog
123
VRV Controls Solution
What are your choices?
Multi-Zone Controllers
Zone Controllers
iTC (DCS601C71)
iTM (DCM601A71)
Navigation Remote
Controller (BRC1E73)
Simplified
Remote Controller
(BRC2A71)
Wireless
Remote
Controller
Central
Remote Controller
(DCS302C71)
Interface Solutions
Unified On/Off
Controller
(DCS301C71)
Schedule Timer
(DST301BA61)
External Equipment Control
Interface for
use in BACnet ®
(DMS502B71)
DIII-Net/Modbus®
Adaptor (DTA116A51)
iTM (DCM601A71)
+ BACnet Server
Gateway Option
(DCM014A51)
Interface for use
in LonWorks®
(DMS504C71)
CONTROLS
Adapters
Wiring Adapter
(KRP1C74/75)
124
External Control
Adapter (DTA104A53)
www.daikincomfort.com
RA Interface
Adapter
(KRP928BB2S)
iTM (DCM601A71)
+ BACnet Client
Option (DCM009A51)
WAGO I/O
Daikin WAGO
BACnet ®/IP Controller
(750-831)
Daikin controls offer comfort control in
an easily managed and operated system.
CONTROLS
VRV Product Catalog
125
VRV Control Systems Overview
Multi-Zone Controllers
with iTC HTTP
Option (DCS007A51)
(DCS601C71)
D-NET Air Conditioning
Network Service System
(Optional maintenance service)
Unified On/Off
Controller
(DCS301C71)
Central Remote
Controller
(DCS302C71)
Schedule Timer
(DST301BA61)
(DCM601A71)
BMS
with BACnet® Server Gateway
Option (DCM014A51)
with BACnet
Client Option
(DCM009A51)
Interface for
use in BACnet
(DMS502B71)
Interface for
use in LonWorks®
(DMS504C71)
CONTROLS
DIII-Net/Modbus®
Adaptor
(DTA116A51)
Home automation
master controller
Limitations may apply to some models and functions.
Please contact your local sales office for details.
Note: BACnet® is a registered trademark of the American Society of Heating,
Refrigerating and Air-Conditioning Engineers (ASHRAE). LonWorks® is a
trademark of Echelon Corporation registered in the United States and
other countries. Modbus® is a registered trademark of Modicon.
126
www.daikincomfort.com
Interface Solutions
DIII-NET Line
BACnet/Ethernet or LonWorks network
or HTTP communication line
RS485 Modbus line
P1P2 line
Connection line
VRV Indoor Unit
Zone Controllers
Navigation Remote
Controller (BRC1E73)
Simplified Remote
Controller (BRC2A71)
DIII-NET
(Communications Transmission)
DIII-NET, Daikin’s unique communication
transmission system, links indoor units
and various other building equipment –
in accordance with applications, scale
and conditions and transmits vast
amounts of information between them.
ERV
Wireless Remote
Controller
Interface Adapter
for SkyAir series
(DTA112BA511)
SkyAir
Mini-Split
RA Interface
Adapter
(KRP928BB2S)
External Equipment Control
WAGO I/O
Building services equipment:
»
»
»
»
»
BACnet /IP
®
CONTROLS
Daikin WAGO BACnet®/IP
Controller (750-831)
Sensors
Ventilation Equipment
Building Lights
Pump
Valve
Complete Control of
External Equipment with
Custom Programming
Dedicated Outside Air Supply
(DOAS)
BACnet®/IP
DVS DOAS System
Light Commercial RTU
DDC
VRV Product Catalog
127
Individual Controllers
BRC1E73 - Navigation Remote Controller
The Navigation Remote Controller has been enhanced to
meet the configuration requirements of Daikin’s VRV indoor
units. The BRC1E73 provides all the great features and options
the market requires. The configurable display and operation
buttons will provide as much or as little control as the
project requires.
Features and Benefits
»» Basic Operation
-- On/Off, operation mode, setpoint
-- Up to 5 fan speeds selectable (enhanced)
-- Airflow direction (enhanced)
-- Individual louver airflow direction
-- Dual airflow
-- Auto-draft prevention (prevents air
blowing directly on occupants)
»» Function
-- Configurable display — Detailed, Standard, and Simple
-- Dual or single cool and heat setpoints for occupied periods
-- Independent setback setpoints for unoccupied periods
-- Automatic Setback by occupancy sensor
-- Automatic Off by occupancy sensor
-- Unwanted buttons/operation modes can be disabled
-- Setpoint range limitation
-- Individual button prohibits/lockout
-- Auto-changeover for Heat Recovery and Heat Pump
systems with dual or single setpoints
-- Self-cleaning filter panel
CONTROLS
-- Automatic adjustment for Daylight
Savings Time (DST) (enhanced)
-- Built in 7, 5+2, 5+1+1, and 1 (everyday) schedule with up
to 5 actions per day with independent cooling, heating
and setback setpoints
»» More Features
-- Backlit display
-- Room temperature sensor
-- 12/24 hour clock
-- Fahrenheit/Celsius selectable
-- English/French/Spanish languages selectable
-- Remote control group - up to 16 indoor units
128
www.daikincomfort.com
Auto-changeover
Secondary
Primary
Cooling SP
(1 to 4˚F)
(1 to 4˚F)
Change to Cooling
Change to Cooling (with Guard Timer)
Dual Sp. Min Differential (0 to 7˚F) or Single Sp.
Heating SP
Primary
Secondary
(1 to 4˚F)
(1 to 4˚F)
Change to Heating (with Guard Timer)
Surely Change to Heating
Automatic changeover is available for Heat Pump system and
Heat Recovery systems. The setpoint for cooling and heating
are configurable with a minimum differential of 0 to 7° F or
single setpoint. The changeover is automatically controlled
to happen in either of the following two cases:
1. Case 1: Changeover at the primary changeover
temperature after the guard timer expires.
-- In default, the primary changeover setpoint is 1° F above
cooling setpoint or 1° F below heating setpoint, which is
configurable between 1° F – 4°F.
-- In default, the guard timer is 60 minutes, which is
selectable among 15, 30, 60 (default) or 90 minutes.
-- The initiation of guard timer is built in to help prevent
frequent changeover which may cause energy loss.
2. Case 2: Changeover at the secondary changeover
temperature.
-- In default, the secondary changeover temperature is
1° F above the primary changeover temperature for cooling
or 1°F below the primary changeover temperature for
heating, which is configurable between 1° F – 4° F.
-- Case 2 will happen while the guard time is active in case 1.
BRC1E73 - Navigation Remote Controller (continued)
Configurable Display Mode – Detailed, Standard, Simple
DISPLAY MODE
DETAILED
STANDARD
Clear display
»» Backlit display
SIMPLE NEW
-- Backlight helps operating
in dark rooms.
»» Dot matrix display
Display Image
On/Off status on LED
(LED blinks when an
error occurs)
Mode
Setpoint (Dual/Single)
Room temperature
Fan speed
Airflow direction (when
a louver is available)
Day and Time
Status icon
Key lock icon
Error message
n
n
-- A combination of fine dots
enables various icons.
n
n
1
n
1
n
1
n
2
n
2
n
2
3
n
3
n
n
n
-- Large text display is easy to see.
Simple operation
n
3
»» Large buttons and arrow keys
n
n
3
n
3
n
n
n
n
n
3
FF can be displayed instead of the operation mode while the unit is turned off with the field setting
O
2
Can be removed from the display while the unit is turned off with a field setting
3
Can be removed from the display with a field setting
1
-- Large buttons and arrow keys
enable easy operation. Basic
setting such as fan speed and
temperature can be intuitively
operated. For other settings
just select the function
from the menu list.
On/Off Display Option
Optional Face Decals –
Hides unnecessary (locked/prohibited) buttons
USED WITH
SINGLE SETPOINT MODE
DUAL SETPOINT MODE
CONTROLS
Model
On/Off
Mode
Fan
Up, Down
Left, Right
Menu/Ok
Cancel
BRC1E72RM
BRC1E72RF
BRC1E72RMF
BRC1E72RM2
BRC1E72RF2
BRC1E72RMF2
n
n
n
n
n
n
n
n
n
n
n
n
n
n
VRV Product Catalog
n
n
n
n
n
n
n
n
n
129
Individual Controllers
(cont.)
On/Off
Indoor unit is turned
Off when no one
detected in space
BRC1E73 - Navigation Remote Controller (continued)
Occupant returns and
indoor unit required to
be turned on manually
On
Energy saving
»» Automatic Off by occupancy sensor†
Unoccupied 2 hrs.
»» Auto Setback by sensor†
Auto Off
-- The indoor unit will turn off
when it is determined that the
room is unoccupied after a
specified time has elapsed.
-- The cooling and heating
Energy
savings when
setpoints will gradually
relax
room is unoccupied
(configurable) internally when
the room is determined
0
2
to be unoccupied.
-- Can be used in conjunction
with the Auto Setback by sensor function
T (hrs)
-- The internal setpoint
will return to the original
Occupied
Unoccupied
Occupied
setpoint when room occupancy is detected.
Automatic Off energy savings
Automatic setback energy savings
On/Off
Cooling
Setpoint
(°F)
80
Occupant returns and
indoor unit required to
be turned on manually
Auto Setback Setpoint
Indoor unit is turned
Off when no one
detected in space
On
Unoccupied 2 hrs.
Auto Off
Setback setpoint
increases 2°F every 15 min.
room is unoccupied
76
Unoccupied
15 min.
74
Occupied setpoint returned
when occupancy is detected
Energy savings when
room is unoccupied
0
2
Occupied
Occupied
College classroom sample (a summer Monday case)
CONTROLS
Auto Setback Setpoint
1)Cooling
8:30 ON
2) 10:30 OFF
Setpoint
Setback setpoint
The first
and the air
In the second period, the classroom is
(°F) period starts
increases 2°F every 15 min.
conditioner
the is
cooling
operation.
unoccupied and the air conditioner stops.
80 starts
room
unoccupied
Energy savings
when room is
unoccupied
78
76
Unoccupied
15 min.
74
3) 13:00
Occupied setpoint returned
when occupancy is detected
ON
0
15 operation
30
When the third period
starts,
starts again.
Occupied
Unoccupied
130
0
T (hrs)
Unoccupied
4) 15:00 OFF
OFF
45 the third 60
T (hr)
After
period, the classroom
becomes vacant again and the air
conditioner stops. Occupied
www.daikincomfort.com
Energy savings
when room is
unoccupied
78
Occupied
15
30
Unoccupied
45
60
T (hr)
Occupied
Comfort
»» Individual airflow direction†
Individual airflow direction
(2)
-- Airflow direction of each of the four air
outlets can be controlled individually.
Outlet mark
-- (Positions 0 to 4, Swing, and No individual setting
are selectable.)
»» Auto airflow rate†
(3)
(1)
-- Airflow rate is automatically controlled in accordance
with the difference between room temperature and
set temperature.
†
nly available for VRV 4-Way Flow Ceiling Suspended type
O
FXUQ-P series and Ceiling Mounted Cassette (Round Flow
with Sensing) type FXFQ-T series.
(4)
(1)
(2)
(3)
(4)
VRV Product Catalog
CONTROLS
With 18 configurable airflow distribution patterns, the controls aid
efficiency and provides a comfortable environment.
131
Individual Controllers
(cont.)
BRC4C82/BRC7E818/BRC7E83/BRC7E830 Wireless Remote Controller
BRC2A71 - Simplified Remote Controller
»» Economical controls solution
»» Suitable for use in hotels rooms, hallways, reception areas
»» The same operation modes
and settings as with
wired remote controllers
are possible.
-- I n d i v i d u a l
airflow
direction, auto airflow rate
and sensing sensor control
can be set only via
wired remote controller
BRC1E73. Cannot be
set via other remote
controllers.
and conference rooms
»» Features
-- On/Off
-- Operation mode
-- Single setpoint
-- Fan speed adjustment
Signal receiver unit*
(separate type)
-- Can be used with the optional remote
temperature sensor for sensing room
temperature
Wireless remote*
controller
Simplified
remote
controller
»» A compact signal receiver unit (separate type) to be
mounted into a wall or ceiling is included.
-- The Ceiling Suspended and Wall Mount indoor units
use signal receivers that are mounted in the indoor unit.
*Wireless remote controller and signal receiver unit are sold as a set.
Summary
REMOTE CONTROLLER COMPATIBILITY WITH VRV INDOOR UNITS
FXFQ-TV
Navigation remote controller (Wired remote controller)
Wireless remote controller (Installed type signal receiver unit)
Wireless remote controller (Separate type signal receiver unit)
Simplified remote controller
n
FXZQ
FXUQ
FXDQ
FXMQ
FXHQ
FXAQ
FXL(N)Q
FXTQ
FXEQ
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n No louver control function
INDIVIDUAL CONTROL CAPABILITIES
System Capabilities
CONTROLS
Communications
°F/°C Selector
Backlit LCD display
Room temperature display
Schedule and setback capabilities (with Time and Date display)
User restriction options
On/Off, Operation mode, Setpoint, Fan speed
Louver position adjustment
Reports system malfunctions
Space temperature sensor
Simultaneous operation with Daikin multi-zone controllers
Simultaneous operation with BACnet® and LonWorks®
Group control capacity
132
www.daikincomfort.com
Daikin Controls Options
BRC1E73
Navigation
Remote Controller
BRC2A71
Simplified Wired
Remote Controller
2 Wire / DIII Net
2 Wire / DIII Net
°F only
Infrared
°F only
n
n
n
n
n
n
n
n
n
n
Up to 16 indoor units
Up to 16 indoor units
Up to 16 indoor units
n
Wireless Remote
Controller (model depends on unit)
n
n
n
n
n
n
n
n
n
By providing individual zone control, the occupant of each space has the
ability to set the room temperature where they feel most comfortable.
CONTROLS
VRV Product Catalog
133
Advanced Multi-Zone
Controllers
DCM601A71 - intelligent Touch Manager (iTM)
The intelligent Touch Manager (iTM) is an advanced multizone controller that provides the most cost-effective way to
control and monitor the Daikin VRV system.
Centralized and Advanced VRV Control
Up to 64 Indoor Unit Groups (128 actual Indoor Units) can
be monitored and controlled with individual Cool and Heat
Setpoints, Setpoint Range Limitation, Setback Setpoints,
and Auto changeover to meet your expectations and project
requirements. Up to 512 Indoor Unit Groups (1024 actual
Indoor Units) can be monitored and controlled with the addition
of up to 7 optional iTM Plus Adapters. (DCS601A72)
Ancillary Equipment Control
Integrates and/or interlocks sensors, switches, dampers, fans,
pumps, and lighting with Daikin Indoor Units.
Web Access and Alert E-mail
Allows daily remote monitoring and control with the Web/Email function that can be accessed via the facility’s Local Area
Network or your Internet connection. Sends Error E-mail to
mobile devices with the Web/E-mail function.
Tenant Billing
Determines energy consumption of shared condensing units
based upon tenant (Indoor Unit) demand using the PPD
Software option (DCM002A71).
Features
»» 10.4" LCD touch screen, USB drive
»» Advanced, scalable and cost-effective management system
-- Up to 650 points (max 512 indoor unit groups
(1024 indoor units)
-- Floor plan layout view
»» Advanced Auto changeover
-- Applicable to both VRV Heat Pump and
Heat Recovery systems
-- Fixed, Individual, Average and Vote methods
»» Web Accessibility and Alert Email (standardized)
-- All screen views and configuration menus can
be accessed through Web
»» WAGO I/O
-- Monitor and control 3rd party equipment
with DI, DO, AI and AO signals
-- Up to 512 management points
-- Interlock function with indoor units and
ancillary equipment
»» Power Proportional Distribution Option (DCM002A71)
-- Calculates apportionment of outdoor unit’s total
power consumption to individual units on the system
»» iTM BACnet® Client Option (DCM009A51)
CONTROLS
Functions
-- Enabling the BACnet Client option allows
the iTM to use the BACnet IP protocol
»» Dual setpoints or Single setpoint in Occ or
Setback in Unocc
-- Allows for full monitoring and control of 3rd party
BACnet capable equipment
»» Setpoint Range Limitation
-- Up to 512 BACnet management points
»» Scheduling (7 day, Weekday-Weekend,
Weekday-Saturday-Sunday, Everyday)
»» Optimum Start and Timed Override
»» iTM BACnet Server Gateway Option (DCM014A51)
-- Provides functionality to monitor and control indoor units
(up to 128 indoor units groups) by a BMS via BACnet/IP.
-- Virtual router function embedded that enables individual
and configurable Device IDs for each indoor unit group.
134
www.daikincomfort.com
iTM System Overview
BACnet®/IP
Ethernet
Web access
BMS
Integration of Third
Party Equipment
BACnet® Server Gateway
(DCM014A51)
Full Control of Daikin
VRV System
Up to 512 groups
(1024 indoor units)
Fire alarm
Di/Pi port
kWh meter
Ethernet (BACnet IP)
DIII-NET
DCM601A71
RS485
BACnet Client Option
(DCM009A51)
®
RS485
iTM Plus Adapter
WAGO I/O
one DIII-NET system
Max. 64 indoor unit groups (128 indoor units)
Max. 64 indoor unit groups
Di/Pi port
Lighting
Fan
Max. 64 indoor unit groups
Pump
Sensor
Max. 64 indoor unit groups
CONTROLS
KRP928
Adapter
up to 30 nodes
Dedicated Outside Air Supply
(DOAS)
Up to 7 adaptors
DVS DOAS System
Light Commercial RTU
DDC
VRV Product Catalog
135
Advanced Multi-Zone
Controllers (cont.)
DCS601C71 – intelligent Touch Controller (iTC)
Centralized and Advanced VRV Control
Up to 64 Indoor Unit Groups (128 actual Indoor Units) can
be monitored and controlled with individual Cool and Heat
Setpoints, Setpoint Range Limitation, Setback Setpoints,
and Auto changeover to meet your expectations and project
requirements. Up to 128 Indoor Unit Groups (256 actual Indoor
Units) can be monitored and controlled with the addition of
the Optional DIII-Net Plus Adapter (DCS601A72).
Ancillary Equipment Control
Integrates and/or interlocks sensors, switches, dampers, fans,
pumps, and lighting with Daikin Indoor Units.
Web Access and Alert E-mail
Functions
Allows daily remote monitoring and control with the Web/Email Software option that can be accessed via the facility’s
Local Area Network or your Internet connection. Sends Error
E-mail to mobile devices with the optional Web/E-mail
Software option (DCS004A71).
»» Advanced Zone Level Control
Tenant Billing
Determines energy consumption of shared condensing units
based upon tenant (Indoor Unit) demand using the PPD
Software option (DCS002A71).
Features
»» Color LCD touch panel icon display
»» Simplified engineering
»» Multi language (English, French, Italian, German, Spanish)
»» Yearly schedule
»» Independent dual or single setpoints for
occupied and setback operation
»» Auto heat/cool changeover
CONTROLS
»» Enhanced history function
»» Simple Interlock Function
»» Doubling of number of connectable indoor units
by adding a DIII-NET Plus Adapter (option)
136
www.daikincomfort.com
-- Add advanced temperature control functions
from a single multi-zone controller
»» Independent Cool, Heat, and Setback Setpoints
»» Advanced Auto changeover
-- Applicable to both VRV Heat Pump and Heat
Recovery systems
-- Fixed, Individual, and Average methods
»» Scheduling (7 day, Weekday-Weekend,
Weekday-Saturday-Sunday)
»» Centralized Control with three different view styles
»» Setpoint Range Limit
»» Simple interlock
»» PPD (tenant billing option) (DCS002A71)
»» Web server/alarm email (DCS004A71)
»» HTTP interface (option) (DCS007A51)
iTC system overview
Centralized and advanced VRV control
Ancillary equipment control
Key card
Digital input
(DI) unit
Emergency/forced
shutdown
Occupancy
sensor
Digital input/output
(DIO) unit
Ancillary
equipment
D
Damper
DIII-Net Plus
Adapter
Pulse input
Ethernet
Energy meter
Power Proportional Distribution (PPD)
- apportions total outdoor unit power consumption
among indoor units with optional PPD software
PC
Web access and alert e-mail
Tenant power consumption
CONTROLS
VRV Product Catalog
137
Centralized Controllers
DCS302C71 - Central Remote Controller
Maximum 64 groups (zones)
of indoor units can be
controlled individually.
»» Maximum wiring length 3280 ft. (Total: 6560 ft.)
»» Maximum 64 groups (128
indoor units) controllable
»» Airflow volume and direction can be controlled
individually for indoor units in each group operation.
»» Maximum 128 groups
(128 indoor units) are
controllable by using 2 Central Remote Controllers,
which can control from 2 different places.
»» Ventilation volume and mode can be controlled
for Energy Recovery Ventilator.
»» Zone control
»» Malfunction code display
CONTROLS
138
www.daikincomfort.com
»» Connectable with Unified ON/OFF Controller,
Schedule Timer and BMS system
»» Up to 4 ON/OFF pairs can be set per day
by connecting a schedule timer.
DCS301C71 - Unified On/Off Controller
DST301BA61 - Schedule Timer
Maximum 16 groups of indoor
units can be operated
simultaneously/individually.
Maximum 128 indoor units can be
operated by programmed schedule.
»» Maximum 16 groups (128
indoor units) controllable
»» Operating status indication
(Normal operation, Alarm)
»» Centralized control indication
»» Maximum wiring length 3280 ft. (total: 6560 ft.)
»» Compact size casing (thickness: 0.63in)
»» Connectable with Central Remote Controller,
Schedule Timer and BMS system
»» Maximum 128 indoor
units controllable
»» When used in combination with
a Central Remote Controller, a
maximum of 8 weekly schedule
patterns can be set, while the
Central Remote Controller can be used to select
desired zones. Up to 2 ON/OFF pairs can be set per day.
»» Maximum 48 hours back up power supply
»» Maximum wiring length 3280 ft. (total: 6560 ft.)
»» Compact size casing (thickness: 0.63in)
»» Connectable with Central Remote Controller,
Unified ON/OFF controller and BMS system
CONTROLS
The Central Controllers can monitor and control indoor units by either
group or zone. Their easy-to-read liquid crystal displays (LCDs) allow you
to orchestrate and monitor temperature, time, and airflow volume, etc.
across your entire system at the touch of button.
VRV Product Catalog
139
External Equipment
Control
DCM009A51 - iTM BACnet ® Client Option
Features
The iTM offers an advanced and cost-effective solution
for Building Management Systems (BMS) applications.
The iTM BACnet Client Option (DCM009A51) provides more
flexibility to enhance the iTM’s function as a mini BMS. With
this option, the iTM is able to manage DOAS systems and
other third party equipment through the BACnet/IP protocol.
By registering equipment connected to a BACnet server as
management points in the iTM, you can now monitor and
control the equipment via the iTM.
»» Cost- effective BMS solution
»» Direct connection on iTM using the
BACnet/IP Protocol
»» Integrated control on Daikin VRV system
and Daikin Applied System
»» Monitors and controls third party equipment
»» Easy commissioning with pre-engineering Preset Tool
»» Easy monitoring with preconfigured GUI
with BACnet® Client Option
DIII-Net
Ethernet
(BACnet/IP)
MicroTech III
DOAS System
Third Party BACnet Server
Pump
Lighting
Fan
DVS DOAS System
Sensor
VRV System
CONTROLS
Third Party
devices/equipment
Di/Do/Ai/Ao contacts
750-831
Daikin WAGO BACnet/IP
Controller
140
Object Types
Applications
»» Analog Input, Analog Output, Analog Value
»» Simple I/O: Sensor, Pump, Light, Fan
»» Binary Input, Binary Output, Binary Value
»» Multi-State Objects: AHU, Alarm, Elevator
»» Multi-State Input, Multi-State Output,
Multi-State Value
»» The iTM can integrate with the WAGO BACnet/IP Controller
(750-831) using the BACnet Client Server Option
www.daikincomfort.com
External Equipment
Control (cont.)
750-831 - Daikin WAGO BACnet ®/IP Controller
The Daikin WAGO BACnet/IP Controller (750-831) is a
programmable controller that connects the WAGO I/O system
to the BACnet protocol. This controller provides the three
following functionalities:
»» Water Cooled VRV Valve Control: Valve control for
water cooled VRV project
»» Native server: BACnet objects
are generated automatically for
the DI, DO, AI, AO modules that
are connected to the controller.
»» Ambient Enclosure Heater Control: Damper and
auxiliary heater control for outdoor unit dog house
projects in cold climate
»» Application server: Other
supported BACnet objects
can be created via programming and made available to
a BACnet network.
»» Trending: Trending Client for VRV
»» Custom programming available to fit individual
project needs
»» Application client: Using the client
functionality, BACnet objects
and the properties of the external
equipment can be accessed.
750-831
Daikin WAGO BACnet/IP
Controller
Controller with programs
+
WAGO I/O
Modules
750-831
Daikin’s VRV Marketing Controls Group will provide
customizable programming (programming and commission
fees apply) for applications where external equipment
control is needed. The following application programs are
now available:
3rd Party equipment to be controlled
Digital/Analog Inputs and
Outputs from 3rd Party:
»» Dampers
»» Water Pump
»» Valves
BACnet Devices from 3rd Party:
»» Dampers
»» Water Pump
»» Valves
Ethernet and BACnet Client/IP Network
CONTROLS
iTM (DCM601A71) with BACnet
Client Option (DCM009A51)
Other BMS options
Monitoring and Management Options
VRV Product Catalog
141
Interface
Solutions
DCM014A51 - iTM BACnet ® Server Gateway Option
Features
The intelligent Touch Manager is capable of serving as a BACnet
interface for Building Management System (BMS) integration.
The iTM BACnet Server Gateway Option (DCM014A51) will
provide BMS integrators with the ability to monitor and control
the VRV indoor units via the BACnet/IP protocol. The iTM
BACnet Server Gateway Options, eliminates the need for an
additional hardware interface for the BMS to monitor and
control VRV system. The iTM BACnet Server Gateway Option
will provide seamless control logic integration between the
iTM and BMS. With the BACnet Server Gateway Option, up
to 128 indoor units management groups can be controlled
and monitored by BMS.
»» Direct connection on iTM using the BACnet/IP Protocol
»» BACnet virtual router function implemented:
-- Individual BACnet device ID assigned to each
indoor unit group address
-- Indoor unit group names created in the iTM are
visible on the BMS
»» Easy commissioning using CSV file
-- Available objects can be configured for each indoor unit
»» Support Change of Value (COV) notifications to BMS
»» Configurable as a BACnet foreign device if a BBMD
exists a on different subnet within a BACnet network
»» Independent heating and cooling setpoints for
occupied and unoccupied periods
»» Individual min/max setpoint range limitation
for heat and cool modes
»» The iTM’s auto changeover, setpoint range limitation,
setback, dual setpoint logic and schedule can be
accessed by the BMS
BMS
Ethernet (BACnet/IP)
Device ID=530000
Object List
for iTM System Setting
1: 1-00
CONTROLS
ITM (DCM601A71)
with BACnet® Server
Gateway Option
(DCM014A51)
Device ID=531100
Object List
for one indoor unit
2: 1-00
One virtual BACnet network
1: 1-01
Device ID=531101
Object List
for one indoor unit
2: 1-01
1: 1-02
Device ID=531102
Object List
for one indoor unit
2: 1-02
iTM Plus Adaptor
(DCM601A72)
Up to to 7 adaptors
Device ID=532100
Object List
for one indoor unit
142
www.daikincomfort.com
Device ID=532101
Object List
for one indoor unit
Device ID=532102
Object List
for one indoor unit
iTM BACnet ® Server Gateway Option
Better Solution and Easy integration with the iTM BACnet Server Gateway Option
1: 1-00
Individual device instance number
for each indoor unit (configurable)
Object instance number repeated
for every indoor unit point
Device ID (1:1-00) = 531100
1: 1-01
Device ID (1:1-01) = 531101
Occupancy Mode = MO 1 (All indoor units)
Unit On Off Status = BI 2 (All indoor units)
BMS
Schedule
Auto Changeover
Timer Extension Minutes
Emergency Stop
On/Off
Occupied Dual Setpoint
Setback Setpoints
Setpoint Range Limitation
Min. Cool/Heat SP Differential
Setpoint Tracking Mode
Remote Controller Prohibit
Timer Extension
And more basic functions...
iTM Control Logic
Enable/disable iTM schedule operation
Enable/disable iTM auto changeover operation
Timed override minutes
System forced off
Occupancy mode (occ, unocc, standby)
Occupied cooling and heating setpoint
Unoccupied cooling and heating setpoint
Maximum and minimum cooling setpoint
Maximum and minimum heating setpoint
Minimum cooling and heating setpoint differential
Cooling and heating setpoint tracking mode
Remote control prohibit
Timed override operation
Current unit operation (off, normal, override, setback)
Forced indoor unit thermo-off
Indoor unit changeover option availability
Indoor fan status
and more basic operation and monitoring points...
CONTROLS
Indoor Unit Operation and Monitoring
iTM System
Settings
Advanced iTM BACnet Server Gateway Points
Advanced Indoor Unit Operation
The iTM BACnet Server Options links the BACnet points to the logic in the iTM.
VRV Product Catalog
143
Interface
Solutions (cont.)
DMS502B71 - Interface for use in BACnet ®
»» BACnet: Building Automation and Control Networks
DMS504C71 Interface for use in LonWorks®
»» BMS interface based on LonTalk
»» Interface between Daikin DIII-Net and BMS LonTalk
-- Standard open protocol based on ANSI/ASHREA
Standard 135
work station
»» Monitor/Control indoor unit’s points
»» Monitor/Control up to 256 indoor units groups
-- Manages up to 64 indoor unit groups (128 indoor units)
with network variables for each group
(512 indoor units)
»» Certified by BACnet Testing Laboratories (BTL)
»» Manage up to 4 DIII-Net systems
-- Manages 1 DIII-Net system
®
»» Lon Interface communicates over twisted pair wire
»» External Interface File (XIF) documents device information
-- Option Board (DAM411B51) required
available at www.daikinac.com
BACnet, LonWorks and Modbus® Interface overview
Please contact Daikin for compatibility with BMS system
Ethernet
BMS
»Lift
»Pump
»Lighting, etc.
Fire alarm Security
DMS502B71†
(Interface for use
®
in BACnet )
DTA116A51‡
®
(DIII-Net/Modbus
Adapter)
VRV System
Power supply facility
BACnet® is a registered trademark of the American
Society of Heating, Refrigerating and Air-Conditioning
Engineers (ASHRAE).
‡
LonWorks ® is a trademark of Echelon Corporation
registered in the United States and other countries.
‡
Modbus ® is a registered trademark of Modicon, Inc.
DMS504C71‡
(Interface for use
®
in LonWorks )
†
Energy recovery
ventilator
Central Controller
DTA116A51 - DIII-Net Modbus® Adapter
CONTROLS
Daikin's BACnet, LonWorks and
Modbus interface units provides
control for all VRV systems.
»» BMS interface based on Modbus (RS485)
»» Gateway between Daikin DIII-Net and
BMS Modbus workstation
-- Manages up to 16 VRV indoor units connected
to up to 2 outdoor units
»» Modbus interface communicates via Modbus RTU
144
www.daikincomfort.com
VRV Monitoring Services
D-NET Air Conditioning Network Service System
Save energy. Protect your equipment investment. Maintain comfort levels.
D-NET connects your equipment to
our monitoring center over the web.
We continually monitor more than 80
data points in your equipment*, so we
know exactly how your systems are
performing. We also monitor outside
conditions from more than 400 locations across the United
States and Canada, so we know what kind of weather you’re
up against. Putting this information together, we know if
your systems can be optimized remotely to reduce your
energy consumption.
D-NET Air Conditioning Network Service System overview
Internet
I/F unit *
» Malfunction information by e-mail
ACC Center
(Air conditioning Control Center)
» Automatic data transfer
Local contractors
* For an I/F unit, one of the following can be selected:
Local Controller, intelligent Touch Controller, or intelligent
Touch Manager.
CONTROLS
VRV Product Catalog
145
Controls Product List
Individual Controllers
ITEM
Navigation Remote Controller
Wireless Remote Controller
Simplified Remote Controller
MODEL NO.
BRC1E73
BRC4C82
BRC7C812
BRC7E818
BRC7E83
BRC7E830
BRC2A71
FUNCTION
Programmable zone controller
Hand-held zone controller with infrared receiver kit
Non-programmable zone controller
Multi-Zone Controllers and Options
ITEM
MODEL NO.
intelligent Touch Manager
intelligent Touch
Controller
FUNCTION
Air-conditioning management system that can be controlled by touch screen or web browser to monitor
and control up to 64 groups (10 outdoor units)
Maximum of 7 iTM Plus Adapters can be connected to intelligent Touch Manager. Each iTM Plus Adapter can add
up to 64 additional groups (10 outdoor units)
Power consumption of indoor units are calculated based on operation status of the indoor unit and outdoor unit
power consumption measured by kWh meter
intelligent Touch Manager
DCM601A71
iTM Plus Adapter
DCM601A72
iTM PPD Option
DCM002A71
iTM BACnet Client Option
DCM009A51
The BACnet Client Option enables the iTM to control and monitor equipment through the BACnet/IP protocol
iTM BACnet Server Gateway Option*
DCM014A51
The BACnet Server Gateway Option provide BMS integrators with the ability to monitor and control the
VRV indoor units via the BACnet/IP protocol.
intelligent Touch Controller
DCS601C71
Air-Conditioning management system that can control up to 64 groups (10 outdoor units).
DIII-Net Plus Adapter
DCS601A72
Additional 64 groups (10 outdoor units) are possible.
iTC PPD Option
DCS002A71
Power consumption of indoor units are calculated based on operation status of the indoor unit and outdoor
unit power consumption measured by kWh meter.
iTC Web Option
DCS004A71
Provides access to ITC via web browser with PC. Error Email sent when errors occur.
iTC HTTP Interface Option
DCS007A51
Interface to home automation system certified with Crestron Home Automation
Central Remote Controller
DCS302C71
Unified ON/OFF controller
DCS301C71
Schedule Timer
DST301BA61
Up to 64 groups of indoor units (128 units) can be connected, and ON/OFF, temperature setting and monitoring
can be accomplished individually or simultaneously. Connect up to 2 controller in one system.
Up to 16 groups of indoor units (128 units) can be turned, ON/OFF individually or simultaneously, and operation
and malfunction status can be displayed. Can be used in combination with up to 8 controllers.
Weekly schedule can be programmed by the controller for up to 64 groups of indoor units (128 units).
Can turn units ON/OFF twice per day.
* iTM BACnet Server Gateway Option is not compatible with iTM PPD option and iTM BACnet Client option.
Hardware Interface Solutions
ITEM
MODEL NO.
Interface for use in BACnet ®
DMS502B71
CONTROLS
Optional DIII board
DAM411B51
Interface for use in LONWORKS®
DMS504C71
Interface for use in Modbus
DTA116A51
146
www.daikincomfort.com
FUNCTION
Interface unit to allow communications between VRV and BMS.
Operation and monitoring of air-conditioning systems through BACnet ®/IP communication.
Expansion kit, installed on DMS502B71, to provide 2 more DIII-NET communication ports. Not usable independently.
Interface unit to allow communications between VRV and BMS.
Operation and monitoring of air-conditioning systems through LonWorks® communication
Use of the Modbus protocol enables the connection of the VRV system with a variety of home automation and BMS systems
from other manufacturers.
Adaptors
ITEM
Digital Input (Di) Unit
Digital Input/Output (Dio) Unit
MODEL NO.
DEC101A51-US2
DEC102A51-US2
DIII-Net Expander Adapter
DTA109A51
Unification Adapter for
Computerized Control
External control Adapter
for Outdoor Unit
DCS302A72
DTA104A53/61/62
Group Control Adapter
KRP4A71/72/73/74
ABC Terminal Kit
BRP2A81
Wiring Adapter
RA Interface Adapter for DIII-Net Use
RA PCB Adapter for Time Clock
KRP1C74/75
KRP928B2S
KRP413A1S
FUNCTION
Monitor On/Off and Error status of ancillary equipment
Monitor and control of ancillary equipment
Apply to increase the number of outdoor units (up to another 10) connected in one DIII-Net system.
Apply to overcome communication errors in electrically noisy environments.
Turn On/Off the system from a central panel through Centralized Controller or iTouch Controller.
Monitor On/Off and Error Status.
Unified changeover of Cool/Heat mode. To change the mode of several outdoor units by one remote controller.
Demand Control. Low Noise Control: -2 to 3 dB of outdoor unit
Turn On/Off Remote Control Group. Change setpoint (with resistance interface 0-135 ohm).
Monitor On/Off and Error status
Remotely manage the operating mode of the heat pump system. Integration point for ambient
thermostats to engage lock-out
Thermo-on status. Fan status. AUX heater output. Humidifier output
Mini-split can be controlled through DIII-NET
Remotely Start / Stop for mini-split indoor units
WAGO I/O System
MODULE
Basic Kit
Digital Input
Digital Output
2 Channel DI
4 Channel DI
8 Channel DI
2 Channel DO
4 Channel DO
2 Channel AI
Analog Input
4 Channel AI
2 Channel AO
Analog Output
4 Channel AO
PART NUMBER
51291052
750-400
750-432
750-430
750-513/000-001
750-504
750-454
750-479
750-461/020-000
750-455
750-459
750-554
750-550
750-555
750-559
Internal System Power Supply
750-613
Passive Power Supply
24 VDC Jumper
750-602
750-603
DESCRIPTION
Bus Coupler, Connector, 24 VDC Power Supply, and End Module
2 Channel Digital Input Module, 24 VDC
4 Channel Digital Input Module, 24 VDC
8 Channel Digital Input Module, 24 VDC
2 Channel Digital Output Module, without power jumper
4 Channel Digital Output Module, 24 VDC
2 Channel Analog Input Module, 4-20 mA, Differential Inputs
2 Channel Analog Input Module, ± 10 VDC, Differential Measurement Input
2 Channel Analog Input Module, NTC 20k Ohm
4 Channel Analog Input Module, 4-20 mA, single-ended
4 C hannel Analog Input Module, 0-10 VDC, single-ended
2 Channel Analog Output Module, 4-20 mA
2 Channel Analog Output Module, 0-10 VDC
4 Channel Analog Output Module, 4-20 mA
4 Channel Analog Output Module, 0-10 VDC
24 VDC Bus Power Supply Module, Required for use after every
32 contact points connected in a node
24 VDC Power Supply Module, passive
24 VDC Power Jumper Module, for use with 8 channel DI module
PART NUMBER
750-831
759-302/000-923
787-712
750-600
NAME
Daikin WAGO BACnet/IP Controller
WAGO I/O Check USB kit
24 VDC Power Supply
End Module
CONTROLS
Daikin WAGO BACnet®/IP Controller and Parts
DESCRIPTION
WAGO BACnet/IP Controller
WAGO I/O Check CD ROM and service cable
24 VDC Power Supply
WAGO End Module
VRV Product Catalog
147
148
www.daikincomfort.com
Support and Tools
VRV Product Catalog
149
Support and Tools
Daikin’s array of software and support tools are designed to streamline all
stages of project design, application, installation and service/maintenance.
Daikin provides multiple tools to aid the design,
selection, analysis, submission, and general
support for its line up of ductless, rooftop, light
commercial split and specifically for the full line
of Daikin VRV systems.
SUPPORT & TOOLS
150
www.daikincomfort.com
The tools have been designed to be simple to use, easily
accessible and to address the various considerations and
steps in the evolution of a residential or commercial project,
aimed at helping the architect, consulting engineer, contractor,
installation technician, and service company to enhance
workflows and general project execution.
n
Design and
verification
Online and tablet
reference (spec,
data, submittal)
SUPPORT & TOOLS
VRV Product Catalog
n
n
n
n
Online Spare Parts Bank
n
Service Checker
Dr. Daikin
Daikin City (including Guide Specs,
IOMS etc.)
n
VRV Configurator
After sales
and service
n
Daikin eQuip application
Smartphone and
mobile reference
Ventilation Rate Calculator
n
Reference Charge Calculator
n
Revit models
n
CAD drawings
Performance curves for third-party
energy simulation Programs
n
IES-VE Daikin VRV plug-in
n
Online Energy Calculator
Energy screening
and simulation
Controls Configurator
Selection
Ventilation Xpress
CATEGORIES
WebXpress
Daikin VRV support and tools overview
TOOLS
n
n
n
151
Support and Tools (cont.)
WebXpress
IES-VE plug-in for Daikin VRV
Selection software
A key tool for Reps, Consulting Engineers and Contractors to
use is the suite of Xpress selection software. These tools are
web based and windows based EXE file designed to provide
quick, easy and above all accurate selections of VRV systems
and ventilation devices. Inputs can be customized to meet a
variety of project needs and has the following features and
benefits:
»» Fully array of software configuration settings
»» Select and customize indoor unit types with
options/accessories
»» Optimize condensing unit selections based on block
load characteristics
»» Define pipe sizes and lengths and both local and
centralized wiring schemes
»» Define and generate selection reports in Word (DOC),
Excel (XLS), or CAD (DXF) formats
As controls for VRF systems become much more sophisticated
at both a zone and building level, ensuring the full array of
features are captured, Daikin has developed a simple controls
configurator tool allowing the consulting engineer or
contractor to capture all of the features that are needed to
be utilized with the suite of controls products from Daikin so
to ensure that the commissioning engineer can then set-up
and configure the system appropriately at start up.
Energy screening and simulation tools
With the continued trend in looking at building costs beyond
just the 1st cost, accurately screening or simulating the
performance of systems in buildings at the conceptual stage
is more important than ever. Daikin recognizes this need and
has developed a variety of support tools for this purpose.
Online VRV energy calculator
»» Easy access and registration via online.
»» Free of charge and easy to use.
»» Allows for a semi-dynamic energy screening to be completed
for VRV only. Provides useful information such as part load
curves, estimated annualized operating costs etc.
IES-VE plug-in for Daikin VRV
»» One of the leading Energy Simulation programs in Europe
is now gaining awareness and a growing user-base in
North America.
»» With the Daikin VRV plug in for IES-VE you can take
advantage of the enhanced energy simulation capabilities
with the IES platform and combine in a fully validated
modeling methodology for Daikin VRV systems including
the innovative and energy saving “VRT” function.
The results of the IES-VE simulations can be utilized for
LEED, California Title 24 and other regulatory energy
simulation requirements.
»» Performance curve/plug-ins
for 3rd party modeling software
SUPPORT & TOOLS
»» Daikin have developed curves, instructions and sample
building files for a variety of other 3rd party energy
simulation software programs such as:
-- eQuest
- Energy Pro
-- Trace 700
- Energy Plus (VRV HP only)
-- HAP
152
www.daikincomfort.com
Revit
www.DaikinCity.com
Design and verification
Online and tablet reference material
Equipment Selection and Energy Simulation only reflect the
early stages of a project evolution. At Daikin we recognize the
importance of additionally providing resources to the Engineer
and Architect community as well as contractors as follows:
Daikin City serves as the multi-functional portal for all
disciplines interested in or already using Daikin products and
technologies for a project. More than just a typical website,
Daikin City provides:
»» CAD files for all products in multiple formats
»» Energy-saving characteristics of VRV systems in various
(DWG and DXF), etc.
vertical market buildings
»» Revit files for BIM architecture for all products
»» Refrigerant Charge Calculator
»» Product videos and feature summaries via the
communications center
-- Quick check of the total refrigerant charge in a VRV System
based on applied pipe-lengths and combination ratio’s etc
-- Quick check of the minimum room volume (occupied
space) that system charge can be utilized in per ASHRAE
Standard 15-2010 and ASHRAE Standard 34-2010.
»» Ventilation Rate Calculator
-- Easy to use calculator to determine ventilation rates
required for different room sizes and applications in
accordance with ASHRAE Standard 62.1-2013.
»» A fully stocked library of information simply arranged for
ease of finding any piece of Daikin information you may
need such as IOM’s, brochures, engineering data, and
application guides etc (registration required).
»» Easy access to the suite of sales tools that Daikin offer
(registration required).
»» An easy to use product specification library to quickly verify
any spec item required, or to generate a submittal data sheet,
guide spec or confirmation of the available accessories and
options for a specific product (registration required).
SUPPORT & TOOLS
VRV Product Catalog
153
Support and Tools (cont.)
Daikin eQuip application
www.DrDaikin.com
Smartphone and mobile reference
»» With the Daikin eQuip application, available for both iOS
devices and Android devices, you can have the power of
all Daikin product information and support material readily
accessible on your mobile device or tablet.
»» For rapid resolution to a system with an error code, or
general troubleshooting needs, the Dr. Daikin tool is a
helpful and quick reference tool that works via a standard
desktop, tablet or smartphone and even SMS. When you
need to understand or isolate the scope of one of Daikin’s
diagnostic codes, enter the code into the Dr. Daikin
resource and automatically the tool will provide feedback
of what the diagnostic code refers to and straightforward
guidance on how to address the code.
Visit www.drdaikin.com for further information.
SUPPORT & TOOLS
Daikin's tools and support enables consulting engineers, building owners
and installers to optimize the life cycle cost of the VRV systems.
154
www.daikincomfort.com
Daikin VRV Configurator
Daikin’s online spare parts databank
After sales and service
With a strong commitment to sales tools to help design
and apply the product is equally supported with a strong
commitment on after-sales and service tools aimed at the
service contractor or maintenance technician.
»» Daikin VRV Configurator is a PC based software tool
that allows an installing contractor to “set-up” the operating
parameters and field settings of the VRV IV outdoor units
off-site and then use a handy USB connection to upload
those settings during the commissioning process.
This helps save time and ensure that projects with
multiple systems can be set up correctly and error free.
The Configurator tool also allows for up to 48hrs of
operation data from an installed system to be downloaded
to a laptop computer for analysis if needed.
»» Daikin VRV Service Checker is a PC based software tool
that facilitates a connection to the system and monitors
all components of the system including temperatures,
pressures, compressor and fan speeds, and may other
items and can be utilized to understand operational trends
with the system and what is happening in the system at a
specific time. This tool is very helpful when troubleshooting
a system in the event of error or diagnostic notification.
»» Daikin’s online spare parts databank (registration
required) is an easy to use graphically driven means of
identifying what spare or replacement part might be needed
during the life cycle of the VRV equipment. Using this
resource will help you identify the part number, applicable
model, any alternative part options, and the availability of
the part both locally and globally.
»» Daikin University offers Daikin's customers a variety of
quality training programs designed to provide the tools and
resources needed for our customers to be successful.
-- Our courses are designed by training professionals
around specific objectives based on industry needs
and job task analysis. We offer a choice of instructional
settings based on the program goals and our students’
needs including: online/on-demand web-based training,
instructor led webinars, onsite training, and instructor-led
classroom training at one of our many Daikin Authorized
training facilities.
SUPPORT & TOOLS
VRV Product Catalog
155
Notes
156
www.daikincomfort.com
Notes
VRV Product Catalog
157
Notes
158
www.daikincomfort.com
COMMERCIAL
■
R E N OVAT I O N
■
NEW CONSTRUCTION
About Daikin:
Daikin Industries, Ltd. (DIL) is a global Fortune
1000 company which celebrated its 90th
anniversary in May 2014. The company is
recognized as one of the largest HVAC (Heating,
Ventilation, Air Conditioning) manufacturers in the world.
DIL is primarily engaged in developing indoor comfort
systems and refrigeration products for residential,
commercial and industrial applications. Its consistent
success is derived, in part, from a focus on innovative,
energy-efficient and premium quality indoor climate and
comfort management solutions.
WARNINGS:
»» Always use a licensed installer or contractor to install
this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant
leakage, electrical shock, fire or explosion.
»» Use only those parts and accessories supplied or
specified by Daikin. Ask a licensed contractor to install
those parts and accessories. Use of unauthorized
parts and accessories or improper installation of parts
and accessories can result in water or refrigerant
leakage, electrical shock, fire or explosion.
»» Read the User’s Manual carefully before using this
product. The User’s Manual provides important
safety instructions and warnings. Be sure to
follow these instructions and warnings.
»» For any inquiries, contact your local Daikin sales office.
Additional Information
Before purchasing this appliance, read important information
about its estimated annual energy consumption, yearly
operating cost, or energy efficiency rating that is available
from your retailer.
Daikin, and its design, VRV and REFNET are trademarks of Daikin Industries, Ltd.
CT-VRV 10-17
Download PDF
Similar pages