Analogue Meters With Moving - Iron Movement
DPM PGDA / PGDV / PGD3A / PGD3V
© Ziegler Instruments Order No. DPM PGDA / PGDV / PGD3A / PGD3V Data sheet-E1.R0-920819-45-2013-EN
1 / 3 PHASE PROGRAMMABLE
www.ziegler-instruments.com
Version: E 06 / 09 /10
1
|
7
DPM PGDA / PGDV / PGD3A / PGD3V
1 / 3 PHASE PROGRAMMABLE
Applications:
The digital panel meter DPM have been designed for
industrial applications, which frequently require precise and on
site adjustment of the display range. It can be used in industrial
automation and for laboratory uses.
DPM measures important electrical parameters in 3 phase 4
Wire, 3 phase 3 Wire and single phase Network & replaces the
multiple analog panel meters.
Salient Features
n
n
n
n
n
n
n
n
Onsite selection of Auto scroll / Fixed Screen
User can set the display in auto scrolling mode or fixed screen
mode using front panel keys.
4 digits LED display (up to 9999):
Fast & Easy Installation on panel without any need of
external swivel screws (clip-in mounting for 96x96 size only)
True RMS measurement.
4 Digits ultra bright LED Display (up to 9999).
On site Programmable CT/PT Ratios.
User selectable CT Secondary 1A/5A.
User selectable PT Secondary from 100 VLL to 500 VLL.
User selectable 3ph3wire / 3ph4wire / single phase Network.
Wide auxillary Power Supply which can accept any input
between 40V– 300V AC/DC.
Storage of MIN / MAX values.
14mm or 20mm ultra bright 4 digits LED display.
Function keys:
Using two function keys it is possible to Display various
parameters in Current and Voltage DPM. These function keys are
also used for programming Password, Network selection, CT/PT
Primary & Secondary values, Reset min/max values, Auto
ON/OFF mode selection.
Screen No. storage
In case of power failure, the instrument memorizes the last
screen stored. For every 1 min. the instrument stores the screen
no. in the non-volatile memory.
Product Features:
True RMS measurement
The instrument measures distorted waveform up to 15
Harmonic.
User can program on site the network connection as either 3
Phase 3 Wire or 4 Wire or single phase network using front
panel keys.
Min Max storage of parameters possible
th
On site programmable PT/CT ratios:
The instrument stores minimum and maximum values for System
Voltage(in case of PGDV / PGD3V) and System Current (in case
of PGDA / PGD3A). Every 60 sec stored values are updated.
It is possible to program primary of external potential Transformer
(PT) for Voltage DPM & primary of external Current Transformer
(CT) for Current DPM on site via front panel keys by entering into
Programming mode.
Low back depth
User selectable CT Secondary 5A/1A
Available in two different Sizes:
The secondary of external Current Transformer (CT) can be
programmed on site to either 5A or 1A for Current DPM using
front panel keys.
DPM is available in two different sizes 96x96 and 48x96.
User selectable PT Secondary
The secondary of external Potential Transformer (PT) can be
programmed on site from 100 VLL to 500 VLL for Voltage DPM
using front panel keys.
Higher Security
Provides Security with user programmable password protection.
User selectable CT Primary
The instrument has very low back depth (behind the panel) of
less than 54mm for 96x96 and 68mm for 48x96 type DPM.
Enclosure Protection for dust and water:
Conforms to IP 50 (for front face) & IP 20 (for back) as per
IEC60529.
EMC Compatibility
Compliance to International standard IEC 61326.
Interference Emission : IEC 61326-1 : 2005, Class A
Interference Immunity : IEC 61326-1 : 2005
n
n
n
n
The Primary of current transformer can be programmed on site
from 1A to 999kA for Current DPM using front panel keys.
User selectable PT Primary
The Primary of Potential transformer can be programmed on site
from 60 VLN to 999 kVLN for single Phase Voltage DPM &
100VLN to 999 kVLL for three Phase Voltage DPM using front
panel keys.
© Ziegler Instruments Order No. DPM PGDA / PGDV / PGD3A / PGD3V Data sheet-E1.R0-920819-45-2013-EN
n
User selectable 3 phase 3Wire or 4Wire or Single
phase Network
n
n
n
Electrostatic discharge : IEC 61000-4-2 -- 4kV/8kV
(ESD)
contact/air.
EM Field
: IEC 61000 -4-3 -- 10 V/m (80 MHz to
1 GHz)
-- 3 V/m (1.4 GHz to 2 GHz)
-- 1 V/m (2 GHz to 2.7 GHz)
Burst
: IEC 61000 -4-4 -- 2 kV (5/50 ns, 5
kHz)
Surge
: IEC 61000 -4-5 -- 1 kVLL / 2 kVLN.
Conducted RF
: IEC 61000 -4-5 -- 3 V (150 kHz to 80
MHZ)
www.ziegler-instruments.com
Version: E 06 / 09 /10
2
|
7
DPM PGDA / PGDV / PGD3A / PGD3V
1 / 3 PHASE PROGRAMMABLE
n
n
n
Rated Power Frequency
magnetic Field
: IEC 61000 -4-8 -- 30 A/m
Voltage dip
: IEC 61000 -4-11 -- 0% during 1
cycle.
-- 40% during 10/12
cycles.
-- 70% during 25/30
cycles.
Short interruptions
: IEC 61000-4-11 -- 0% during 25/30
cycles.
25 cycles for 50 Hz
test
30 cycles for 60 Hz
test.
Accuracy:
Voltage
±0.5% of range + 1 Digit (10...
100% of Nominal value)
±0.5% of range + 1 Digit (10...
100% of Nominal value)
Current
Influence of Variations:
Temperature coefficient :
(for rated value range of use
(0…50°C))
0.025% /°C for Voltage
0.05%/°C for Current
Display update rate:
Response time to step input
1 sec approx.
Technical Specifications
:
Input Voltage (PGDV / PGD3V):
Applicable Standards:
Nominal input voltage
(AC RMS)
Max continuous input voltage
Nominal input voltage burden
Phase –Neutral 290VL-N
Line-Line
500V L-L
120% of rated value
< 0.3 VA approx.per phase.
EMC
Safety
System PT secondary values
For Single Phase DPM- 60VLN to
290VLN programmable on site &
for Three Phase DPM- 100VLL to
500VLL programmable on site.
Safety :
System PT primary values
For Single Phase DPM- 60VLN to
999kVLN programmable on site &
for Three Phase DPM- 100VLL to
900kVLL programmable on site.
IEC 61326-1: 2005
IEC 61010-1-2001 , Permanently
connected use
IEC60529
IP for water & dust
Pollution degree:
Installation category:
High Voltage Test
2
III
3.3 kV AC, 50Hz for 1 minute
between Aux. and measuring
inputs
Environmental:
Nominal input current
System CT secondary values
System CT primary values
Max continuous input current
Nominal input current burden
5A AC RMS
1A & 5A programmable on site.
From 1A up to 999kA
(for 1 or 5 Amp )
120% of rated value
< 0.2 VA approx. per phase
40 V – 300V AC/DC
45 to 65 Hz
3 VA Approx.
(± 5 % )
Current
Front :
Back :
IP 50
IP 20
Dimensions and Weights :
a) 96x96 DPM
Overload Withstand:
Voltage
0 to +50°C
-25°C to +70°C
0... 90% non condensing
Minimum 3 minute
15g in 3 planes
10... 55 Hz, 0.15mm amplitude
Enclosure:
Auxiliary Supply:
External Aux
Frequency range
VA burden
Operating temperature
Storage temperature
Relative humidity
Warm up time
Shock
Vibration
© Ziegler Instruments Order No. DPM PGDA / PGDV / PGD3A / PGD3V Data sheet-E1.R0-920819-45-2013-EN
Input Current (PGDA / PGD3A):
2 x rated value for 1 second,
repeated 10 times at 10 second
intervals
20x rated value for 1 second,
repeated 5 times at 5 min intervals
Bezel size
Panel cut-out
Overall depth
Weight
96 mm x 96 mm DI N 43 718.
92 +0.8 mm x 92 + 0.8mm.
55 mm.
310 gm. Approx.
b) 48x96 DPM
Operating Measuring Ranges:
Voltage Range
Current Range
Frequency
10… 120% of rated value
10 … 120% of rated value
45…65 Hz
Bezel size
Panel cut-out
Overall depth
Weight
96 mm x 48 mm DI N 43 718
92 + 0.8 mm x 43.5 + 0.6 mm.
68 mm.
250 gm. Approx.
Reference conditions for Accuracy:
Reference temperature
Input waveform
Input frequency
Auxiliary supply voltage
Auxiliary supply frequency
23°C +/- 2°C
Sinusoidal (distortion factor 0.005)
50 or 60 Hz ±2%
Rated Value ±1%
Rated Value ±1%
www.ziegler-instruments.com
Version: E 06 / 09 /10
3
|
7
DPM PGDA / PGDV / PGD3A / PGD3V
1 / 3 PHASE PROGRAMMABLE
Parameters measured and displayed:
A) PGD3V
B) PGD3A
Network
type
Displayed
Parameter
1) 3 Phase 4 wire
Network
type
a. Phase –Neutral Voltage VR
b. Phase –Neutral Voltage VY
c. Phase –Neutral Voltage VB
Displayed
Parameter
1) 3 Phase 4 wire
a. Phase Current AR
and 3 Phase 3 Wire
b. Phase Current AY
c. Phase Current AB
d. Line-Line Voltage VRY
d. System Current A
e. Line-Line Voltage VYB
e. Max. system Current A
f. Line-Line Voltage VBR
f. Min. system Current A
g. System Voltage V
2) 1 Phase 2 wire
h. Max. system voltage V
a. Phase Current A
e. Max. Phase Current A
i. Min. system voltage V
2) 3 Phase 3 wire
f. Min. Phase Current A
a. Line-Line Voltage VRY
b. Line-Line Voltage VYB
c. Line-Line Voltage VBR
d. System Voltage V
e. Max. system voltage V
f. Min. system voltage V
3) 1 Phase 2 wire
a. Phase –Neutral Voltage V
b. Max voltage V
c. Min voltage V
© Ziegler Instruments Order No. DPM PGDA / PGDV / PGD3A / PGD3V Data sheet-E1.R0-920819-45-2013-EN
Connection Diagram:
A) For 96x96 DPM (PGD3V / PGD3A)
2
5
8 11
13 14
2
5
8
13 14
L N
+ -
L
O
A
D
Connection For PGD3V 3PH - 4 Wire
Network
1 3 4 6 7 9
O
A
D
Connection For PGD3V 3PH - 3 Wire
Network
1
13 14
L N
+ -
L1
L2
L3
Aux Supply L
L1
L2
L3
Aux Supply
L
O
A
D
Connection For PGD3A 3PH – 4 Wire
Network
3
7
9
Connection For PGD3V 1PH
Network
1
L
O
A
D
Connection For PGD3A 3PH – 3 Wire
Network
L
O
A
D
L1
N
13 14
Aux Supply
N
+ Aux Supply
L N
+ -
L1
L2
L3
13 14
L
L N
+ -
Aux Supply
L1
L2
L3
N
2 11
3
13 14
L N
+ -
L1
L2
L3
Aux Supply
L
O
A
D
Connection For PGD3A 1PH
Network
www.ziegler-instruments.com
Version: E 06 / 09 /10
4
|
7
DPM PGDA / PGDV / PGD3A / PGD3V
1 / 3 PHASE PROGRAMMABLE
For 96x96 DPM (PGDV / PGDA)
1
2
13 14
13 14
1 3
L N
+ Aux Supply
L N
+ Aux Supply
L
O
A
D
L1
N
N
Connection For PGDV 1PH
Network
*Note:
L
O
A
D
L1
Connection For PGDA 1PH
Network
For Measurement of parameters in PGD3V DPM Voltage must be present between terminal 2 & 11 for single phase or 3 phase 4
wire network and between terminal 2 & 5 or 2 & 8 for 3 phase 3 wire network. And for PGD3A DPM current must be present
between terminal 1 & 3 for 3 phase 4 wire or 3 phase 3 wire or single phase network.
B) For 48x96 DPM (PGD3V / PGD3A)
3
5
6
A
B
1
3
5
A
N L
- +
L
O
A
D
A
O
A
D
Connection For PGD3V 3PH - 3 Wire
Network
1
B
2
5
6
A
N L
+ -
L
O
A
D
L1
N
Connection For PGD3V 1PH
Network
5
B
A
B
Aux Supply
L1
L
O
A
D
Connection For PGD3A 3PH – 3 Wire
Network
Connection For PGD3A 3PH – 4 Wire
Network
6
L N
+ -
Aux Supply
L1
L2
L3
L
O
A
D
A B
- +
Aux Supply
N L
- +
Aux Supply
L1
L2
L3
11
N L
Aux Supply L
L1
L2
L3
Connection For PGD3V 3PH - 4 Wire
Network
1 2 3 4 5 6
2
N L
- +
Aux Supply
L1
L2
L3
N
B
L
O
A
D
N
© Ziegler Instruments Order No. DPM PGDA / PGDV / PGD3A / PGD3V Data sheet-E1.R0-920819-45-2013-EN
1
Connection For PGD3A 1PH
Network
For 48x96 DPM (PGDV / PGDA)
5
6
A
B
5 6
N L
N L
- +
Aux Supply
- +
Aux Supply
L
O
A
N
D
Connection For PGDV 1PH
Network
L1
A B
L
O
A
D
L1
N
Connection For PGDA 1PH
Network
*Note: For Measurement of parameters in PGD3V LD DPM Voltage must be present between terminal 1 & 6 for single phase or 3 phase 4
wire network and between terminal 1 & 3 or 1 & 5 for 3 phase 3 wire network. And for PGD3I LD DPM current must be present
between terminal 5 & 6 for 3 phase 4 wire or 3 phase 3 wire or single phase network.
www.ziegler-instruments.com
Version: E 06 / 09 /10
5
|
7
DPM PGDA / PGDV / PGD3A / PGD3V
1 / 3 PHASE PROGRAMMABLE
Installation
Easy Clip in Installation on Panel for 96 x 96 size:
Easy Clip-in
mounting for
96x96 size
No need of swivel screws
For 96x96 DPM
Mounting Position
B)
© Ziegler Instruments Order No. DPM PGDA / PGDV / PGD3A / PGD3V Data sheet-E1.R0-920819-45-2013-EN
A)
Installation Cutout
For 48x 96 DPM
Mounting Position
Installation Cutout
www.ziegler-instruments.com
Version: E 06 / 09 /10
6
|
7
DPM PGDA / PGDV / PGD3A / PGD3V
1 / 3 PHASE PROGRAMMABLE
Ordering information
Ordering Code
PROGRAMMABLE DPM
DPM Panel Cutout
96x96 DPM
48x96 Low Depth DPM
Parameter Type
3 Phase Current
3 Phase Voltage
Single Phase Current
Single Phase Voltage
Display Type
14mm Display digit height
20mm Display digit height
(available in 96x96 size only)
96x96
48x96
PGD3A
PGD3V
PGDA
PGDV
14mm
20mm
Order Code Example:
PROGRAMMABLE DPM– 48x96 - PGD3A – 14mm
PROGRAMMABLE DPM, 48x96 Low Depth, 3 Phase Current, 14mm display digit height, Aux. – 40-300V AC/DC
Standard Product :
Product
Code
DPM 96x96 (14mm) : 3PH 3/4W, I/P – 100 to 500 VLL, Aux. 40V – 300V AC/DC
DPM 96x96 (20mm) : 3PH 3/4W, I/P – 100 to 500 VLL, Aux. 40V – 300V AC/DC
DPM 96x96 (14mm) : 3PH 3/4W, I/P – 5A/1A, Aux. 40V – 300V AC/DC
DPM 96x96 (20mm) : 3PH 3/4W, I/P – 5A/1A, Aux. 40V – 300V AC/DC
DPM 48x96 (14mm) : 3PH 3/4W, I/P – 100 to 500 VLL, Aux. 40V – 300V AC/DC
DPM 48x96 (14mm) : 3PH 3/4W, I/P – 5A/1A, Aux. 40V – 300V AC/DC
Product
Code
Ordering Information
DPM 96 x96
DPM 96 x96
DPM 96 x96
DPM 96 x96
DPM 48 x96
DPM 48 x96
( 14mm) : 1 PH, I /P – 60 t o 290 VLN, Aux. 40V
( 20mm) : 1 PH, I /P – 60 t o 290 VLN, Aux. 40V
( 14mm) : 1 PH , I/P – 5A/ 1A , Aux. 40 V – 300V
( 20mm) : 1 PH, I /P – 5A/ 1A, Aux. 40 V – 300V
( 14mm) : 1 PH, I /P – 60 t o 290 VLN, Aux. 40V
( 14mm) : 1 PH, I /P – 5A/ 1A, Aux. 40 V – 300V
P6530010RIS
P6531010RIS
P6532010RIS
P6533010RIS
P6535010RIS
P6536010RIS
© Ziegler Instruments Order No. DPM PGDA / PGDV / PGD3A / PGD3V Data sheet-E1.R0-920819-45-2013-EN
Ordering Information
– 3 00V AC/DC
– 3 00V AC/DC
AC/DC
AC/DC
– 3 00V AC/DC
AC/D C
P6530510 RIS
P6531510 RIS
P6532510 RIS
P6533510 RIS
P6535510 RIS
P6536510 RIS
ZIEGLER INSTRUMENTS
Schnepfenreuther Weg 6, D-90425 Nürnberg, Germany.
TEL.
FA X .
(+49)(911) 38 492 45
(+49)(911) 32 26 212
E-MAIL
WEBSITE
info@ziegler-instruments.com
www.ziegler-instruments.com
made
in
Germany
www.ziegler-instruments.com
Version: E 06 / 09 /10
7
|
7
Download PDF
Similar pages