HP StorageWorks 60 Modular Smart Array

QuickSpecs
HP StorageWorks 60 Modular Smart Array
Overview
The HP StorageWorks 60 Modular Smart Array enclosure is a 2U Serial Attach SCSI (SAS) disk drive storage enclosure supporting
3.5" SAS and Serial ATA (SATA) drives. This enclosure delivers industry-leading data performance, availability, storage density, and
upgradeability to meet customers' demanding and growing storage needs. This enclosure is designed to support 3.5" Universal SAS
or SATA hard drive form factors. The MSA60 enclosure supports direct attach storage (DAS) to HP ProLiant and HP Integrity Servers.
The MSA60 supports the cascading of shelves in a 1+3 configuration to allow a maximum of 48 drives in an 8U configuration
behind each of the two external ports on the HP Smart Array P800 or the HP Smart Array E500 for a total of 96 drives in 8
enclosures (this single controller port incorporates four lanes for a total max throughput of 12Gb/s for SAS). The MSA60 also
supports the HP Smart Array P600 controller. Behind the single external port on the HP Smart Array P600 controller 1+3 cascading
allows a maximum of 48 drives in an 8U configuration.
For HP-UX and Open VMS environments on HP Integrity Servers the MSA60 supports the HP (AH303A) SC44Ge Host Bus Adapter.
Behind the single external port on the HP (AH303A) SC44Ge Host Bus Adapter 1+3 cascading allows a maximum of 48 drives in
an 8U configuration. The HP (AH303A) SC44Ge Host Bust Adapter will only support HP-UX and Open VMS environments and will
be available on all rack mounted HP Integrity Servers with PCIe slots.
What's New
Dual Domain (Only with the HP (AH303A) SC44Ge Host Bus Adapter - will only support HP-UX and Open VMS environments
and will be available on selected HP Integrity Servers only)
Dual domain SAS creates redundant pathways from servers to storage devices. The redundant paths created by these
configurations reduce or eliminate single points of failure within the storage network. This provides increased levels of
high availability with redundant paths from the controller to the drives. Dual domain SAS implementations make it
possible to tolerate host bus adapter (HBA) failure, external cable failure, expander failure, cable pulls, expander failure
and failure in a spanned disk (JBOD) environments.
The HP StorageWorks Dual Domain I/O Module Option Kit (hereafter referred to as "I/O Module") builds on the current
MSA60 design by providing a field upgrade Option Kit for dual I/O module. The I/O module will enable transition from
single domain to dual domain capability to the MSA60 for customers looking for higher levels of redundancy and reliability.
The addition of the I/O Module with the HP SC44Ge Host Bus Adapter adds support for Multi Initiator JBOD Clusters. It will
support HP-UX and Open VMS on selected HP Integrity servers only. The MSA60 with the I/O Module and the HP SC44Ge
Host Bus Adapter will not support ProLiant servers. Multi Initiator JBOD clusters are supported with dual port SAS drives only.
Support for HP Serviceguard software on HP-UX with HP-UX 11iv2/11iv3 only. HP Serviceguard monitors the health of each
node and rapidly responds to failures in a way that minimizes or eliminates application downtime.
NOTE: HP Integrity servers that are supported:
rx2660, rx3600, rx6600, rx7640, rx8640, Superdome sx2000 (only the version that support PCI-e cards)
DA - 12627
Worldwide — Version 13 — February 11, 2008
Page 1
QuickSpecs
HP StorageWorks 60 Modular Smart Array
Overview
Front panel LEDs and buttons
1. Heartbeat LED
2. Fault LED
3. UID button/LED
Rear Panel components
1. Power Supply 1
2. System fan 1
3. Dual 7 segment display board (for future use)
4. SAS in connector
5. SAS out connector
DA - 12627
6.
7.
8.
9.
I/O module bay
I/O module bay
System fan 2
Power supply 2
Worldwide — Version 13 — February 11, 2008
Page 2
QuickSpecs
HP StorageWorks 60 Modular Smart Array
Overview
At A Glance
2U rackmount form factor
3 Gb/s SAS host connectivity
Multi Initiator support (HP-UX and Open VMS on selected HP Integrity Servers) with dual port SAS drives only
Supports HP SAS 3 Gb/s disk drives, (36 GB, 72 GB, 146 GB and 300 GB capacities)
Supports HP SATA 1.5 Gb/s disk drives, (250 GB, 500 GB,& 750 GB capacities)
Maximum storage capacity of 3.6 TB (with twelve HP SAS 3 Gb/s,) or 9TB (with twelve HP SATA 1.5 Gb/s 750 GB hard
drives)
1+3 Cascade support (behind a single SAS port)
Supports boot from storage
Redundant hot-plug power supplies and fans standard
Addition of second I/O Module adds Dual Domain capability providing higher level of redundancy and reliability
DA - 12627
Worldwide — Version 13 — February 11, 2008
Page 3
QuickSpecs
HP StorageWorks 60 Modular Smart Array
Standard Features
Modular Smart Array
Family
The HP StorageWorks Modular Smart Array family delivers simple, affordable storage technology to
meet today's demanding and growing IT needs. These storage solutions offer the best price/performance
and best price/availability features for direct attach environments, small clusters, workgroups and entrylevel SAN environments. Each solution is designed for easy deployment, secure operation, and reduced
management costs while driving rapid return on investment.
MSA60
The HP StorageWorks MSA60 Enclosure (hereafter referred to as "MSA60") is a disk drive storage
enclosure with 3 Gb/s SAS host connectivity. These enclosures deliver industry-leading availability,
storage density, and upgradeability to meet customers' demanding and growing storage needs. The
MSA60 delivers the ideal mix of low-cost and high capacity, for minimum I/O workloads such as
reference data, archival, and disk-to-disk backup.
Key Features
2U rackmount form factor
SAS host interface
Multi Initiator support (HP-UX and Open VMS on selected HP Integrity Servers) with dual port SAS
drives only
Supports twelve 3.5" hot pluggable drives
Ability to support 36GB, 72GB ,146GB & 300GB 3.5" 3Gb/s SAS drives
Ability to support 250GB, 500GB & 750GB 3.5" 1.5Gb/s SATA drives
Modular design
1+3 Cascade support (behind a single SAS port)
SATA 1.5Gb/s - Delivering data transfer rates greater than 100MB/s
Provides storage capacity of up to 9TB per enclosure (using 750GB SATA disk drives)
Hot pluggable disk drives, power supplies, and fans
Redundant fans and power supplies ship as standard equipment with base enclosure
Each MSA60 enclosure comes with dual power supplies that are sufficient to provide power to the
enclosure and maintain normal operating levels
Integrated Environmental Monitoring - Monitors environmental conditions within the enclosure
and components such as the power supply, fans and temperature
Easy removal of parts provides better serviceability. No tools are required!
Supports MS Windows 2003, Red Hat Linux, SUSE Linux, Novell NetWare, HP-UX 11iv2 and
11iv3, Open VMS 8.3 1H
Supported with Smart Array P800, the Smart Array E500 or the Smart Array P600 controller for
HP ProLiant Servers and HP Integrity Servers
Attached to HP SC44Ge Host Bus Adapter for HP-UX and Open VMS support on selected HP
Integrity Servers (servers that support PCI-e cards)
Supported with ACU, ORCA and HP Systems Insight Manager through configuration utilities
provided via the Smart Array controller
RoHS compliant
3 year limited warranty (MSA60 enclosure only)
Pre-Failure warranty that covers SAS and SATA disk drives (See note below)
NOTE: Customer must be running HP Systems Insight Manager in order to qualify for Pre-Failure
warranty. The enclosure is only covered for the warranty period of the drive (3 years for SAS and 1 year
for SATA drives).
DA - 12627
Worldwide — Version 13 — February 11, 2008
Page 4
QuickSpecs
HP StorageWorks 60 Modular Smart Array
Product Highlights
High Levels of Storage
Density, Data Protection,
and Functionality
Low Total Cost of
Ownership
Storage Capacity – The MSA60 enclosure supports up to twelve SAS drives for a maximum
capacity of 3.6TB SAS drives or 9TB with SATA drives
Data Protection – MSA60 is designed for a high level of data protection. It includes redundant
fans and power supplies (standard), and support for various RAID level including RAID6 with ADG
(depending upon the Smart Array Controller used)
Dual Domain - Dual domain SAS creates redundant pathways from servers to storage devices.
The redundant paths created by these configurations reduce or eliminate single points of failure
within the storage network. This provides increased levels of high availability with redundant paths
from the controller to the drives.
Storage Manageability – The MSA60 features familiar configuration and management tools such
as Array Configuration Utility (ACU) and HP Systems Insight Manager (SIM). Online Management
Features include: Online Capacity Expansion, Online RAID Level Migration, Online Stripe Size
Migration, Online Spares (Global)
Choice of Computing Platform – The MSA60 is designed and qualified for HP ProLiant and HP
Integrity servers
Advanced Data Guarding (RAID 6 with ADG) Fault Tolerance – It allocates two sets of parity
data across drives and allows simultaneous write operations. This level of fault tolerance can
withstand two simultaneous drive failures without downtime or data loss.
The modular, scalable design of the MSA60 provides an extremely flexible platform. You can buy what
you need today and purchase additional capacity as your data storage needs grow, instead of making a
large up-front investment. Additional drives and enclosures can be easily added as your needs dictate.
Cascading – The MSA60 has the unique capability of cascading up to 4 – four enclosures behind
a single SAS port (depends on the Smart Array Controller).
Tiered Storage - MSA60 supports mixing SAS and SATA drives in the same enclosure, allowing
you to more effectively utilize mission critical storage where you need it most.
Universal SATA Hard Drive - Since the MSA60 supports HP Universal SATA drives, your
investment in disk drives is protected and cost is minimized as you add new drives.
Pre-Failure Warranty – Drives installed in a MSA60 and monitored under HP Systems Insight
Manager are supported by a Pre-Failure (replacement) Warranty (3 years for SAS and 1 year for
SATA drives). Pre-Failure Warranty allows for the replacement of designated drives in MSA60
before they actually fail when using HP Systems Insight Manager on HP ProLiant or HP Integrity
servers.
NOTE: Some operating systems may not support all of these features.
Integrated Configuration and Management Tools – The MSA60 utilizes the standard, integrated
set of Smart Array management and utility software for HP ProLiant Servers. These tools
consistently lower the cost of ownership by reducing training and technical expertise necessary to
install and maintain HP server storage. HP-UX and Open VMS uses HP Integrity ODE for storage
enclosure support.
DA - 12627
Worldwide — Version 13 — February 11, 2008
Page 5
QuickSpecs
HP StorageWorks 60 Modular Smart Array
MSA60 Components
MSA60 Enclosure
The 2U array houses up to twelve 3.5" Universal hot pluggable SAS or SATA drives.
Each MSA60 includes the following standard components:
MSA60 base enclosure with redundant power supplies and fan modules
Rack mounting hardware kit
0.5m mini-SAS cable
Two AC power cords and two PDU interconnect cords
Smart Array P800
Features
HP's highest performing 16-port PCI-express controller with expander support
Expander support enables the addition of external storage, allowing increased number of drives
for increased performance
Provides highest level of data protection standard by using RAID 6 with Advanced Data Guarding
Supports a maximum total of 104 hard drives (96 drives across eight enclosures plus 8 drives in
the server internal backplane)
Smart Array E500
Features
HP's first external connect only PCI Express (PCIe) Serial Attached SCSI (SAS) RAID controller
Expander support enables the addition of external storage, allowing increased number of drives
for increased performance
Offers RAID 0, 1 & 0+1 and can be upgraded with battery-backed write cache (BBWC) module
for RAID 5
Supports a maximum total of 108 hard drives
HP (AH303A) SC44Ge
Host Bus Adapter
SAS technology delivers high performance and data bandwidth up to 3 Gbps per physical link.
PCI Express x8 capable
PCIe x8 (2.5 GB/s bandwidth)
RAID
Several fault tolerant configurations keep data available and servers running while drives are being
replaced – RAID levels that offer fault tolerance include:
RAID 6 with ADG: Allocates the equivalence of two parity drives across multiple drives and allows
simultaneous write operations.
Distributed Data Guarding (RAID 5): Allocates parity data across multiple drives and allows
simultaneous write operations.
Drive Mirroring (RAID 1 and 1+0 Striped Mirroring): Allocates half of the drive array to data and
the other half to mirrored data, providing two copies of every file.
Dual Domain (NEW)
Dual domain SAS creates redundant pathways from servers to storage devices. The redundant paths
created by these configurations reduce or eliminate single points of failure within the storage network.
This provides increased levels of high availability with redundant paths from the controller to the drives.
Dual domain SAS implementations make it possible to tolerate host bus adapter (HBA) failure, external
cable failure, expander failure, failure in a spanned disk (JBOD) environments.
DA - 12627
Worldwide — Version 13 — February 11, 2008
Page 6
QuickSpecs
HP StorageWorks 60 Modular Smart Array
Software Components
Utilities
Configuration Utilities
Management/Health
Utilities
The MSA60 utilizes a single, consistent set of utility software for storage and RAID management, setup,
configuration and troubleshooting. This consistency reduces the cost of ownership by reducing the
training and technical expertise necessary to install and maintain your HP server storage solution.
Array Configuration Utility (ACU) [On-line for Microsoft and Linux, Remote Web-Based & Off-line]
Option ROM Configuration for Arrays (ORCA), NetWare ACU CPQONLIN (only online support no Web
based support)
HP Systems Insight Manager
Array Configuration Utility
(ACU)
Provides a graphical view of HP drive array configurations.
Easy to use Wizards for configuration.
Web Based ACU supports On-Line, Remote Web Based and Off-line configuration.
Supports on-line configuration for Microsoft, NetWare and Linux.
HP Systems Insight
Manager
Powerful storage, server and server option management tool.
Monitor storage from a remote central location.
Browser based Insight Manager 7 provides full access from anywhere on the Intranet, eliminating
the need for a dedicated Insight Manager console.
Supported Operating
Systems
HPUX 11iv2/11iv3
Microsoft Windows 2003/R2 Standard x64
Microsoft Windows Server 2003/R2 Enterprise
Microsoft Windows Server 2003/R2 Enterprise x64
Microsoft Windows Server 2003 on Itanium
Microsoft Windows 2004/R2 Web
Microsoft Windows 2003/R2 SBS
Novell Open Enterprise Server, NetWare 6.5 SPS
Open VMS V8.3 1H
Red Hat Enterprise Linux
Red Hat Enterprise Linux 3 (AMD64/EM64T)
Red Hat Enterprise Linux 4 for IA64
Red Hat Enterprise Linux 5 for IA64
SUSE Linux Enterprise Server
SUSE Linux Enterprise Server 10 for IA64
SCO OpenServer 5.0.7, 6
SCO UnixWare 7.1.3
SCO UnixWare 7.1.4
NOTE: HPUX 11iv2/11iv3 (for Dual Domain only)
Needs I/O Module (#AG779A), and HP SC44Ge Host Bus Adapter
Qualified for the following HP Integrity servers:
rx2660, rx3600, rx6600, rx7640, rx8640, Superdome sx2000 (only the version that support PCI-e
cards)
NOTE: Open VMS (for Dual Domain only)
Needs I/O Module (#AG779A), and HP (AH303A) SC44Ge Host Bus Adapter
Qualified for the following HP Integrity servers:
rx2660, rx3600, rx6600, rx7640, rx8640, Superdome sx2000 (only the version that support PCI-e
cards)
DA - 12627
Worldwide — Version 13 — February 11, 2008
Page 7
QuickSpecs
HP StorageWorks 60 Modular Smart Array
Software Components
Service and Support
Three-year limited parts only warranty, including hardware diagnostic support, pre-failure warranty
(coverage of hard drives, memory and processors). The warranty is fully supported by HP Services and a
worldwide network of resellers and service providers. In addition 90-day's getting started software
telephone support may be covered under the warranty or available for an additional fee. Enhancements
to warranty services are available through HP Care Pack services.
NOTE: The MSA60 has a limited 3 year parts only warranty. The SAS drives have a 3 year warranty
SATA drives have a 1 year warranty
Care Pack services provide a range of life cycle support options that let you choose the service levels that
meet your business requirements, from basic to mission-critical.
A full range of HP Care Pack hardware and software services are available including:
Installation and start up
Education courses
Extended onsite hardware coverage hours from same business day 13 hours, 5 day to 24 hours, 7
days call window with options including 4-hour response or 6-hour Call To Repair
Comprehensive range of software technical support for Microsoft, Linux, ProLiant Essentials
solutions helping to deliver high level of application availability. Response times range from 30
minutes for critical problems to 2 hours.
System Management, Performance Services and Mission Critical Support Solution
Service includes HP branded hardware options qualified for the storage enclosure, purchased at the
same time or afterwards, internal to the enclosure. These will be covered at the same service level and
coverage period as the storage enclosure.
NOTE: For more information on HP Care Pack services, contact any of our worldwide sales offices or
resellers or visit our worldwide Web site on the Internet at: http://www.hp.com/hps/carepack
NOTE: For more complete information on HP Services offerings, customers and resellers, please visit us
at: http://www.hp.com/hps
NOTE: Additional information regarding worldwide limited warranty and technical support is available
at: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html
HP Care Pack Information Flexible Support
1 Year Support
3 Year Support
DA - 12627
Worldwide — Version 13 — February 11, 2008
HA101A1-87G
HA103A1-87G
HA104A1-87G
HA105A1-87G
HA109A1-87G
HA110A1-87G
HA111A1-87G
HA112A1-87G
HA101A3-87G
HA103A3-87G
HA104A3-87G
HA105A3-87G
HA109A3-87G
Page 8
QuickSpecs
HP StorageWorks 60 Modular Smart Array
Service and Support, HP Care Pack, and Warranty Information
4 Year Support
5 Year Support
Fixed Care Packs
DA - 12627
Installation & Start-Up
HP 1Y NBD,9X5 MSA60 HW Support
HP 1Y 4h 13x5 MSA60 HW Support
HP 1Y 4h 24x7 MSA60 HW Support
HP 1y 6h CTR MSA60 HW Support
HP 3y NBD 9x5 MSA60 HW Support
HP 3y 4h 13x5 MSA60 HW Support
HP 3y 4h 24x7 MSA60 HW Support
HP 3y 6h CTR MSA60 HW Support
HP 1y PW NBD MSA60 HW Support
HP 1y PW 4h 13x5 MSA60 HW Support
HP 1y PW 4h 24x7 MSA60 HW Support
HP 1y PW 6h CTR MSA60 HW Support
Hardware Installation, Electronic
Worldwide — Version 13 — February 11, 2008
HA110A3-87G
HA111A3-87G
HA112A3-87G
HA101A4-87G
HA103A4-87G
HA104A4-87G
HA105A4-87G
HA109A4-87G
HA110A4-87G
HA111A4-87G
HA112A4-87G
HA101A5-87G
HA103A5-87G
HA104A5-87G
HA105A5-87G
HA109A5-87G
HA110A5-87G
HA111A5-87G
HA112A5-87G
HA113A1-564
UF297E
UF298E
UF299E
UF300E
UF301E
UF302E
UF303E
UF304E
UF305PE
UF306PE
UF307PE
UF308PE
U8132E
Page 9
QuickSpecs
HP StorageWorks 60 Modular Smart Array
Configuration Information
Step 1: Base Configuration
Model
MSA60
I/O Module (NEW)
MSA60 bundles
Shipping Dimensions
Part Number
35.25 x 23.5 x 15.75 in (89.5 x 59.7 x 40.0 cm)
418408-B21
HP StorageWorks Modular Dual Domain I/O Module Option Kit
AG779A
NOTE: The I/O Module is a field upgradeable Option Kit the addition of which in the MSA60 will allow
dual domain capability providing higher level of redundancy and reliability.
HP (AH303A) SC44Ge Host Bus Adapter required. Supports only HP-UX and Open VMS on selected HP
Integrity Servers only.
HP StorageWorks MSA60 1.8TB SAS HDD Bundle (MSA60 w/12 146 GB 15K SAS
AG822A
LFF SP HDD)
HP StorageWorks MSA60 9TB SATA HDD Bundle (MSA60 w/12 750 GB 15K SATA
AG823A
LFF SP HDD)
HP StorageWorks MSA60 3.6TB SAS HDD Bundle (MSA60 w/12 300 GB 15K SAS
AG824A
LFF SP HDD)
NOTE: Drives in the bundles are Single Port drives only
NOTE: The MSA60 bundles will be available in the Americas, Asia Pacific (AP) and Japan only. They will
not be available in Europe, Middle East and Africa.
Step 2: Array Controllers
Smart Array Controllers
Supported
(Single Domain)
SAS Controllers
Supported
(Dual Domain)
Description
Part Number
HP ProLiant Servers
HP Smart Array P800 controller
381513-B21
HP Smart Array E500 controller
435129-B21
HP Smart Array P600/256 BBWC Controller
337972-B21
HP Integrity Servers
HP Smart Array P800 controller
AD335A
HP Smart Array E500 controller
AH226A
HP Smart Array P600/256 BBWC Controller
337972-B21
NOTE: The Smart Array P600 supports the cascading of shelves in a 1+3 configuration to allow a
maximum of 48 drives in an 8U configuration behind or the HP Smart Array P600 controller as the P600
has only a single external port.
NOTE: : The Smart Array E500 offers RAID 0, 1 and 0+1 and can be upgraded with ProLiant server to
RAID 5 with battery-backed write cache (BBWC) module - 383280-B21.
HP Integrity Servers
HP SC44Ge Host Bus Adapter
AH303A
NOTE: Only HP-UX and Open VMS on selected HP Integrity servers supported.
HP Integrity servers that are supported:
rx2660, rx3600, rx6600, rx7640, rx8640, Superdome sx2000 (only the version that support PCI-e
cards).
DA - 12627
Worldwide — Version 13 — February 11, 2008
Page 10
QuickSpecs
HP StorageWorks 60 Modular Smart Array
Configuration Information
Step 3: Choose HP ProLiant Server(s)/HP Integrity Server(s)
Server Compatibility
HP ProLiant ML310 G3
HP ProLiant ML310 G4
HP ProLiant ML350 G5
HP ProLiant ML370 G5
HP ProLiant ML570 G4
HP ProLiant DL320 G4
HP ProLiant DL320 G5
HP ProLiant DL320s
HP ProLiant DL360 G5
HP ProLiant DL365
HP ProLiant DL380 G5
HP ProLiant DL385 G5
HP ProLiant DL580 G4
HP ProLiant DL585 G2
HP Integrity Server rx2660 with combination PCIx/PCIe riser only
HP Integrity Server rx3600 with combination PCIx/PCIe backplane only
HP Integrity Server rx6600 with combination PCIx/PCIe backplane only
HP integrity Server rx7640 with combination PCIx/PCIe only
HP integrity Server rx8640 with combination PCIx/PCIe only
HP integrity Server sx2000 with combination PCIx/PCIe only
NOTE: HP ProLiant servers above may not support all Smart Array controllers, see matrix on:
ftp://ftp.compaq.com/pub/products/servers/ProLiantstorage/arraycontrollers/compatability-matrix.pdf
NOTE: HP Integrity Server home:
http://www.hp.com/products1/serverconnectivity/support_matrices.html
Step 4: Choose Hard Drives
SAS Drives
SATA Drives
HP 36GB 3G 15K SAS SP HDD (3.5-inch)
375868-B21
HP 72GB 3G 15K SAS SP HDD (3.5-inch)
375870-B21
HP 146GB 3G 15K SAS SP HDD (3.5-inch)
375872-B21
HP 300GB 3G 15K SAS SP HDD (3.5-inch)
431944-B21
HP 72GB 3G 15K SAS DP HDD (3.5-inch)
384852-B21
HP 146GB 3G 15K SAS DP HDD (3.5-inch)
384854-B21
HP 300GB 3G 15K SAS DP HDD (3.5-inch)
416127-B21
NOTE: In a single domain environment Dual Port (DP) SAS drives will function as Single Port (SP) drives
only.
NOTE: Only Dual Port (DP) SAS drives will work in the Dual Domain environment. Dual Domain
environment requires the HP StorageWorks I/O Module Option (# AG779A).
HP 750 GB 1.5G SATA 7.2K 3.5" HDD
432341-B21
HP 500 GB 1.5G SATA 7.2K 3.5" HDD
395473-B21
HP 250 GB 1.5G SATA 7.2K 3.5" HDD
349239-B21
NOTE: SATA drives are not Dual Port drives
NOTE: There is a known compatibility issue with some early 3.5" SATA HDD that will make them unable
to be used with the MSA20. Customers should verify that they are not using hard drive part number
356536-002/003 (spare 353044-001).
The following SATA hard drives require SATA FirmWare flash in order to work properly. They are:
DA - 12627
Worldwide — Version 13 — February 11, 2008
Page 11
QuickSpecs
HP StorageWorks 60 Modular Smart Array
Configuration Information
500GB SATA 1.5 - Model # 6H500F0, min F/W rev: HA431DD0
80GB RoHS Mask Rom SATA 1.5, Model # 6L080M0, min F/W rev BACE1GG0
160GB RoHS Mask Rom SATA 1.5, Model # 6L160M0, min F/W rev BACE1GG0
250GB RoHS Mask Rom SATA 1.5, Model # 6L250S0, min F/W rev BACE1GG0
NOTE: Go to the HP Hard Drive Compatibility table for complete drive compatibility information
(http://www.hp.com/products/harddiskdrives). Using hard drives in unsupported configurations will
result in voiding the warranty and could result in damage to the drive and/or loss of data.
Step 5: Choose Rack Option
HP Racks
HP Universal Rack 10642 G2 Pallet ALL
HP Universal Rack 10642 G2 Shock Rack
HP Universal Rack 10642 G2 Crated ALL
HP Universal Rack 10642 G2 w/Ext Shock Rack
HP Universal Rack 10636 G2 Pallet ALL
HP Universal Rack 10636 G2 Shock Rack
HP Universal Rack 10636 G2 Crated ALL
HP Universal Rack 10636 G2 w/Ext Shock Rack
HP Module Cooling System
HP Rack S10614 (14U) Rack Cabinet – Shock Pallet
AF001A
AF002A
AF003A
AF004A
AF011A
AF012A
AF013A
AF014A
AF092A
292302-B22
Step 6: Choose Cables
Cable Options
Cables used for connecting the HP Smart Array P800/512 BBWC Controller (P/N 381513-B21 or
AD335A ) or the HP Smart Array E500 (P/N 435129-B21 or AH226A) to MSA60
Mini SAS 4x 2M Cable All
407339-B21*
Mini SAS 4x 4M Cable All
432238-B21*
Mini SAS 4x 6M Cable All
432239-B21*
* #0D1 will appear after this part number on your sales order if factory integration is indicated.
Cables used for connecting the HP Smart Array P600/512 BBWC Controller (P/N 337972-B21) or
the HP SC44Ge Host Bus Adapter (P/N AH303A) to MSA60
SAS 4x to Mini SAS 4x 2M
419571-B21*
SAS 4x to Mini SAS 4x 4M
419572-B21*
SAS 4x to Mini SAS 4x 6M
419573-B21*
*#0D1 will appear after this part number on your sales order if factory integration is indicated.
DA - 12627
Worldwide — Version 13 — February 11, 2008
Page 12
QuickSpecs
HP StorageWorks 60 Modular Smart Array
Technical Specifications
LED Indicators for Drive
Modules (2)
LED Indicators on Front
Panel
LED Indicators on Rear
Panel (6)
Host Interface
Maximum Number of
Drives
Temperature Range
Online (bottom)
Drive Failure/ID (top)
Heartbeat LED
Fault LED
UID button/LED
I/O Module LED
UID button/LED
Heartbeat LED
Fault LED
Power On/Standby button/system power LED
Power supply LED
SAS 3 Gb/s
Up to twelve, 3.5" SAS or SATA drives
Operating
Shipping
Relative Humidity
50° to 95° F (10° to 35° C)
-40° to 150° F (-40° to 66° C)
NOTE: Rated 1°C per 1000 feet of elevation to 10,000 ft.
10% to 90%
Up to 95%
100 to 240 VAC
50 to 60 Hz
3.9A at110 VAC typical, 6A Maximum
345 W
Operating
Non-operating
Input Power Requirements Rated Input Voltage
Rated Input Frequency
Rated Input Current
Input Power (max)
Heat Dissipation
1175 Btu/hr*
(maximum)
*Input Power and Heat Dissipation specifications are maximum values and apply to worst-case
conditions at full rated power supply load. The power/heat dissipation for your installation will vary
depending on the equipment configuration.
User Interface
Controller display with Status indicators (2) and push buttons (4) on front of controller
Logical Drives (LUN)
Up to 32 Logical drives when connected to P800 Smart Array controller
Maximum Logical Drive > 2 TB
Size
RAID 6 with ADG (Advanced Data Guarding
RAID Support
RAID 5 (Distributed Data Guarding)
RAID 1 + 0 (Mirroring and Stripping)
RAID 1 (Mirroring)
RAID 0 (Stripping)
4MB Flashable
Upgradeable Firmware
Disk Drives and Enclosure HP 3.5" SAS 3 Gb/s
Protocol Support
IPass (mini-SAS)
I/O Module
Connector Type
Two (one IN, other is OUT)
Number of Ports
DA - 12627
Worldwide — Version 13 — February 11, 2008
Page 13
QuickSpecs
HP StorageWorks 60 Modular Smart Array
Technical Specifications
MSA60 Enclosure
2U Rack Form Factor
Dimensions (HxWxD)
Weight (base unit)
Weight (with all drives)
3.47 x 17.64 x 23.25 in (8.8 x 44.8 x 59 cm)
34 lb (15.4 kg)
54 lb (24.6 kg)
© Copyright 2008 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice.
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and
services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial
errors or omissions contained herein.
For hard drives, 1 GB = 1 billion bytes. Actual formatted capacity is less.
DA - 12627
Worldwide — Version 13 — February 11, 2008
Page 14
Download PDF
Similar pages