Installation, Operation, Maintenance Manual
CABINEX-EWT
Control System
−Model−
CPX-EWT
EUEWM-128 / 128R
EUEWM-129
EUEWM-130
EUEWM-131
EUEWM-132
EUEWM-MRS
EUEWM-DDS
Manual No. 04-E-0008
CX-22202-8
(CONT-E Rev.8)
HATSUTA SEISAKUSHO CO., LTD.
Jun 01 2011
Installation, Operation, Maintenance Manual
Cabinex-EWT
Control System
04-E-0008
Overview
CABINEX-EWT Control System is an addressable control panel designed for use with
Carbon Dioxide and clean extinguishing agent suppression systems.
Please read and fully understand this manual, before installing and setting up this
system. Keep this manual carefully.
Contents
1. Specification
2. Applicable Standards
3. Parts Name and Description
4. Status
5. Setting
6. Installation
7. Battery Calculation
8. Maintenance
9. Trouble Shooting
1
Installation, Operation, Maintenance Manual
Cabinex-EWT
Control System
04-E-0008
1. Specification
Model: CPX-EWT: Complete Control System
EUEWM-128 / 128 R: Main Panel
EUEWM-129: Manual Release
EUEWM-130: SI Module
EUEWM-131: Discharge Module
EUEWM-132: Relay Module
EUEWM-MRS: Main Reserve Selector Switch
EUEWM-DDS: Discharge Disable Switch
Input voltage: AC100-120V / AC187-240V
(50-60Hz)
Power: 105W Max
AC Input Current: 2A Max (100~240V AC)
Input: Sensor: 2 lines(ZONE 1, ZONE 2)、Single Zone / Cross Zone (OR / AND)
selectable.
Manual release: 1 line.
Output: Notification circuit(Horn & Strobe): 1 line
Actuator: 1 line(Solenoid, Gas Cartridge selectable)
Fire Alarm Relay: DPDT
Pre-Discharge Relay: DPDT
Fault Alarm Relay: DPDT
Recommended Operation temperature range for all models:0-40℃
(tested at FM from 0-49℃, and 90%RH at 38℃)
2. Applicable Standards
This system is designed to comply with the applicable requirements of the following
standards.
NFPA 12: Carbon Dioxide Extinguishing System
NFPA 70: NEC, National Electrical Code
NFPA 72: Fire Alarm Code
NFPA 2001: Clean Agent Extinguishing System
EN 54-2: Fire Detection and Fire Alarm Systems (Control and Indicating Equipment)
EN 54-4: Fire Detection and Fire Alarm Systems (Power Supply Equipment)
2
Installation, Operation, Maintenance Manual
Cabinex-EWT
Control System
04-E-0008
3. Parts Name and Description
SI Module
Main Panel board
Main Panel
(Also available with a round push switch EUEWM-128R and breakable acrylic cover)
3.1 Main Panel board
3
Installation, Operation, Maintenance Manual
Cabinex-EWT
Control System
04-E-0008
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
PARTS NAME
Relay Module
Front Panel
RESET Switch
SILENCE Switch
SCROLL Key
ENTER Key
Fuse: Solenoid Actuator Line
Fuse: Horn & Strobe Line
Fuse: Module Line
Fuse: 24V DC Line
Power Switch
LCD
Terminal for AC Input
FUNCTION
Option
System Reset
Fire/Fault Alarm Silence
Select Command
Enter Command
1.6A
1.0A
3.2A
2.0A
Status Display
-
3.1.1 Front Panel
The Main Panel contains LEDs, buzzer, discharge button.
INDICATION
COLOR
POWER
Green
ZONE 1 FIRE
Red
ZONE 2 FIRE
Red
NANUAL RELEASE Red
FAULT
Yellow
Pre-DISCHARGE
Red
DISCHARGED
Red
DISCHARGE DISABLED Yellow
SILENCED
Yellow
Discharge button
Red
Alarm buzzer
-
DESCRIPTION
On when AC energized, off at AC power off.
Flashes at ZONE 1 detector activates.
Flashes at ZONE 2 detector activates.
Flashes at Manual Release activates.
Flashes at Fault alarm condition.
Flashes at Pre-Discharge condition, off at Discharge condition.
On at Discharge condition.
Flashes at Discharge Disable condition.
Flashes at Alarm silence condition.
Push to activate.
Sounds at Fire and Fault condition.
3.2 Connection
3.2.1 Relay Output
The Main Panel has 6 relay contacts output.
【Specification】
Contact rating: 60W, 125VA Max.
Maximum voltage: AC250V, DC200V
Maximum current: 1A
RELAY
No. of
CONTACT
TERMINAL No.
(NO-NC-C)
DESCRIPTION
Fire alarm
Activates at fire alarm conditon.
2
0-1-2, 20-21-22
2
3-4-5, 23-24-25
Activates at pre-discharge condition.
2
6-7-8, 26-27-28
Activates at fault alarm condition.
Fault
※ Latching ○:Latching: Latches until reset by reset switch.
Pre-Discharge
LATCHING
○
○
×
×:Non-Latching . Automatically returns to Normal condition.
4
Installation, Operation, Maintenance Manual
Cabinex-EWT
Control System
04-E-0008
3.2.2 Battery(Terminal No. 18, 19)
Sealed lead-acid batteries provide back up during AC power failure. Select the size of
battery (max 40AH) to give the required back up time. Use the following specified unit
or equivalent.
E.g.
NP / NPH Series (YUASA CORPORATION)
PE / PX / PXL / PWL Series (JAPAN STORAGE BATTERY)
3.2.3 Output(Terminal No. 38, 39)
Terminal 38-39 is a resettable 24V DC output. To calculate the available output at this
terminal: Add the total current for all modules, solenoids, notification circuits,
detectors, and manual releases. Subtract that total from 3A.
If this value is greater
than 1.5A, 1.5A max is available, if the value is less than 1.5A, the value is the max
available output.
PARTS
SI Module
Discharge Module
Manual Release
Relay Module
Flame Detector
Heat Detector
N.O.C. Detector *
Horn & Strobe
Solenoid Actuator (24V DC)
Solenoid Actuator (12V DC)
Manual Release (N.O.C. type) *
Discharge Disable Switch
Main-Reserve Selector Switch
* N.O.C.: Normally Open Contact
MODEL
EUEWM-130
EUEWM-131
EUEWM-129
EUEWM-132
HIR-7000/7000C
THIS-10/15/20
MT-2475W
2-061-0015
2-061-0014
EUEWM-DDS
EUEWM-MRS
MAXIMUM CURRENT
0.055
0.06
0.06
0.064
0.015
0.17
0.4
0.8
-
3.2.4 SI Module (Terminal No. 14, 15, 16, 17)
This is an interface between the detector and the Main Panel. The detector cannot be
connected directly to the Main Panel. A maximum of 8 SI Modules can be connected to
the Main Panel.
SI Module
5
Installation, Operation, Maintenance Manual
Cabinex-EWT
Control System
04-E-0008
3.2.5 Discharge Module (Terminal No. 10, 11, 12, 13)
This is a module to activate the gas cartridge actuator GHK-10WT used in Hatsuta
extinguishing systems. The harness from the Discharge Module to the gas cartridge
actuator must not be extended, or the actuator may fail to actuate.
When solenoid actuators are used, this module is not required. A maximum of 6
Discharge Modules can be connected to the Main Panel.
Solenoid actuators and gas cartridge actuators can not be combined in one system.
Discharge Module
3.2.6 Solenoid Actuator Output (Terminal No. 30, 31)
This provides a 24V DC 1A max. output to drive solenoid actuators for extinguishing
release. Use the following specified unit or equivalent.
E.g.
2-061-0015 (Chemetron) 24V DC solenoid actuator
2-061-0014 (Chemetron) 12V DC solenoid actuator, use 2 connected in series.
Solenoid actuators and gas cartridge actuators can not be combined in one system.
3.2.7 Notification Circuit Output (Terminal No. 32, 33)
This output is compatible with reverse polarity 24V DC Horn / Strobe devices. When
the system is in fire alarm condition, the Horn & Strobe flashes and produces a loud
sound. Use the following specified unit or equivalent. The maximum output of this
circuit is 0.5A.
E.g.
MT-241575W (Wheelock)
6
Installation, Operation, Maintenance Manual
Cabinex-EWT
Control System
04-E-0008
3.2.8 Manual Release (Terminal No. 34, 35, 36, 37)
When the Manual Release is activated, the actuator will go on immediately without
delay. The Manual Release (EUEWM-129) connects to the Main Panel terminals 34 to
37. A maximum of 2 units can be used. The EUEWM-129 has buzzer and LED display.
These have the same function as the Main Panel.
If normally open contact Manual Releases are used, they must be connected to an SI
Module.
Manual Release (EUEWM-129)
Fitting Dimension for Back Box
DESCRIPTION
INDICATION
Color
On when AC energized, off at AC power off.
POWER
Green
FIRE
Red Flashs at Fire Alarm condition, on when Discharged Conditon
Flashs at Fault Alarm conditon.
FAULT
Yellow
Flashs at Discharge Disabled condition.
DISCHARGE DISABLED Yellow
Discharge button
Red
Push to Discharge.
3.2.9
Discharge Disable Switch
The disable switch provides only a software disable function. The lock out valve must
be used to provide a safe disable for CO2 extinguishing systems.
When the discharge disable key switch is switched to disable mode, the signal to the
actuator is cut and the fault alarm is produced. If the system goes into alarm when in
disable mode, the extinguishing agent will not be discharged.
When solenoid is used the Discharge Disable Switch is wired to open circuit the
solenoid line.
When gas cartridge actuators are used, disconnect the actuator harness.
7
Installation, Operation, Maintenance Manual
Cabinex-EWT
Control System
04-E-0008
Discharge Disable Switch
Fitting Dimension for Back Box and
Wiring Diagram
3.2.10 Lock Out Valve
The lock out valve should be used to safely disable
the CO2 extinguishing system. The limit switch on
the lock out valve can be connected to the SI
module. Set the SI module input to disable switch.
When the lock out valve is closed the actuator
signal will also be disabled.
3.2.11 Main Reserve Selector Switch
When a system uses a reserve supply, this key switch is used to select the main or
reserve supply.
The wiring depends on the type of actuator used. See bellow:
8
Installation, Operation, Maintenance Manual
Cabinex-EWT
Control System
04-E-0008
Main Reserve Selector Switch
Fitting Dimension for Back Box
3.2.12 Detectors
Detectors must be connected to SI Modules. 1 SI Module has 4 detector inputs.
(See wiring diagram.)
Detector type
Flame detector
Model
HIR-7000/7000C
THIS-10/15/20
Heat detector
Smoke detector
* N.O.C.: Normally Open Contact
Description
IR flame detector.
Thirmistor heat detector.
Linear heat detector. (Wire type.)
Normally open contact output.
4 wire smoke detector. (N.O.C. type.)
9
Installation, Operation, Maintenance Manual
Cabinex-EWT
Control System
04-E-0008
IR Flame Detector
Thermistor Heat Detector
4. Status
4.1 Normal Condition
No fire alarm, no fault alarm, AC power on.
NORMAL CONDITION
01.03.15. 21:44
Date: Year. Month. Day and Time (This shows 2001
March 15, 21:44).
Status Screen at Normal Condition
4.2 Fire Alarm Condition
Any 1 or more detectors activate or Manual Release operated.
FIRE ALARM
Shows the detector address that activated and the
D21 17:35 1/3▼
time of activation. 1/3 indicates the displayed
detector is the first of 3 detectors that activated.
Push the scroll key to view the next detector that
activated.
Status Screen at Fire Alarm Condition
4.3 Pre-Discharge Condition
When any sensor activates in Single Zone (OR) mode, or when one or more sensors in
Zone 1 and Zone 2 activates in Cross Zone (AND) mode, the discharge count down will
start.
Pre-DISCHARGE 08
D21 17:35 1/3▼
This is the display during count down (this shows 8
seconds remaining).
Status Screen at Pre-Discharge Condition
10
Installation, Operation, Maintenance Manual
Cabinex-EWT
Control System
04-E-0008
4.4 Discharge Condition
When the Manual Release is activated, or the discharge count down is over, the
actuator is activated to discharge the agent.
DISCHARGED
D21 17:35 1/3▼
Status Screen at Discharged Condition
4.5 Fault Alarm Condition
When any fault occurs, automatically return to normal condition when the fault
repaired.
Shows the error code and the time the error
FAULT ALARM
occurred. 1/2 indicates the displayed error code is
E05 17:25 1/2▼
one of 2 faults. Push the scroll key to view the
next error code.
Error Code (See Table)
Status Screen at Fault Alarm Condition
4.6
Alarm Silence Condition
The Alarm Silence Switch can silence the Horn / Strobe output, and buzzer when
pushed when the panel is in alarm. Silence mode is canceled by the following.
z Push the silence switch again.
z New fire or fault alarm occurs.
z Push the reset switch.
z After 2 hours.
11
Installation, Operation, Maintenance Manual
Cabinex-EWT
Control System
04-E-0008
5. Setting
5.1 Basic Operation
5.1.1 Menu Screen
From normal condition or fault condition, push enter to view the menu screen.
MENU
MODE SETTING ▼
Menu Screen
Menu Contents and Command Description
COMMAND
DELAY TIMER
AND:SINGLE ZONE
SUPPRESSION
OR: CROSS ZONE
SI MODULE DETECTOR ADRESS
ACTUATOR
GAS CARTRIDGE
SYSTEM
TYPE
SOLENOID VALVE
SETTING MANUAL RELEAS
→
ON
RELAY MODULE
OFF
INPUT DATE
→
CLEAR
HISTORY
→
DATA
ALL SETTINGS
VIEW
MODE SETTEING
→
SETTING
SYSTEM SETTING
VIEW
ALARM EVENTS
→
HISTORY
ALL EVENTS
LED, BUZZER
→
→
TEST
MENU
MODE
SETTING
DESCRIPTION
Select delay timer.
Select suppression mode.
Set detector type, address, zone.
Set gas cartridge actuator.
Set solenoid actuator.
Set Manual Release address.
Set relay No. and function.
No Relay Module.
Set date.
Clear the history.
Clear all data.
View MODE SETTING.
View SYSTEM SETTING.
View alarm history.
View all.
LEDs, buzzer test.
5.1.2 Password Input (Authorized personnel only)
Password is required for set up functions. Select each number of the password and
push enter. If the password is incorrect, the system allows the user to input the
password again. Mode Setting, System Setting and Clear Data functions are password
protected and are set by authorized personnel only.
MENU
MODE SETTING
SYSTEM SETTING
CLEAR DATA
VIEW SETTING
LED, BUZZER TEST
PASSWORD
****
****
****
No password
No password
ENTER PASSWORD
_ _ _ _
12
Installation, Operation, Maintenance Manual
Cabinex-EWT
Control System
04-E-0008
5.1.3
Confirm New Settings
After each setting has been changed, the buzzer will sound twice to indicate a change.
Use the menu to confirm the new setting is correct.
5.1.4
Back Step
To back step through the menu, push “SCROLL” for 2 seconds. To escape from the
menu, push “RESET”. If no key is pushed for 2 minutes the display will return to the
status screen.
5.1.5
Scroll
When the “▼” is On, the “SCROLL” key can be used to scroll.
Push “SCROLL”
MENU
MENU
MODE SETTING ▼
5.2
SYSTEM SETTING ▼
Setting the delay timer (MODE SETTING→DELAY TIMER)
Set the delay timer for the actuator output.
COMMAND
0S
5S
10S
20S
30S
60S
5.3
DELAY TIMER
0 Second (No delay time)
5 seconds
10 seconds
20 seconds
30 seconds
60 seconds
DELAY TIMER
10 SECOND
Delay Time Display
AND / OR Setting(MODE SETTING→SUPPRESSION)
Single Zone (OR), Cross Zone (AND) selection.
COMMAND
AND
OR
▼
DESCRIPTION
Cross zone supression mode.
Single zone suppression mode.
13
Installation, Operation, Maintenance Manual
Cabinex-EWT
Control System
04-E-0008
5.4 Sensor Setting
5.4.1
Connection
Below is a block diagram of the detector connections. A maximum of 8 SI modules
can connect to the Main Panel. Each SI Module has 4 detector inputs, giving a
maximum of 32 detectors for 1 system.
Each SI Module has a selectable ID (ID0-ID7). When 8 SI Module are used, detector
address will be D01-D04, D11-D14, ……….D71-D74.
Main Panel
SI module (ID0)
D01
D02
D03
D04
SI module (ID1)
D11
D12
D13
D14
SI module (ID2)
D21
D22
D23
SI module: Max. 8 Unit. (ID 0-7)
14
D24
Detector Address
Installation, Operation, Maintenance Manual
Cabinex-EWT
Control System
04-E-0008
5.4.2 SI Module Setting (SYSTEM SETTING→SI MODULE)
At the Main Panel in the System Settings, the SI Module IDs (0 to 7) must each be set
ON or OFF as appropriate for the system.
COMMAND
ON
SI MODULE ID: *
OFF
(*=0-7)
5.4.3
DESCRIPTION
Use
Not use
Detector Address (SYSTEM SETTING→SI MODULE→DETECTOR ADRESS)
Each detector address is decided by the SI Module’s ID and terminal name.
① ID Switch (ID: 0-7)
E.g. address
D04
SI Module
5.4.4
②Detector Terminal(D1-D4)
Detector Type (SYSTEM SETTING→SI MODULE→DETECTOR ADRESS)
Each detector is connected to the SI Module. There are 3 types of detector that can
connect to the SI Module. The type of detector used on each input must be correctly
selected at the Main Panel.
TYPE
Flame detector
Heat detector
Heat detector
Heat detector
Heat detector
Heat detector
Heat detector
Heat detector
Heat detector
N.O.C. detector
Manual Release
Discharge Disable sw
Not use
MODEL
COMMAND
DESCRIPTION
HIR-7000(C)
THIS(C)-10/15/20
THIS(C)-10/15/20
THIS(C)-10/15/20
THIS(C)-10/15/20
THIS(C)-10/15/20
THIS(C)-10/15/20
THIS(C)-10/15/20
THIS(C)-10/15/20
-
SX-7000
IR flame detector.
Thirmistor (Alarm Temp: 70℃).
Thirmistor (Alarm Temp: 70℃) with barrier.
Thirmistor (Alarm Temp: 100℃).
Thirmistor (Alarm Temp: 100℃) with barrier.
Thirmistor (Alarm Temp: 120℃).
Thirmistor (Alarm Temp: 120℃) with barrier.
Thirmistor (Alarm Temp: 150℃).
Thirmistor (Alarm Temp: 150℃) with barrier.
Normally open contact type detector.
Normally open contact type manual release.
No connection.
THIS-70℃
THIS70 BARRIER
THIS-100℃
THIS100 BARRIER
THIS-120℃
THIS120 BARRIER
THIS-150℃
THIS150 BARRIER
N.O.C. DETECTOR
MANUAL RELEASE
DISABLE SWITCH
OFF
15
Installation, Operation, Maintenance Manual
Cabinex-EWT
Control System
04-E-0008
CAUTION:
* The temperature setting for heat detector (THIS) is set at the Main Panel.
* The table shows normally open contact type Manual Release, this type requires an SI
Module. The EUEWM-129 Manual Release connects directly to the Main Panel and
does not use SI Module.
* When the Discharge Disable Switch is connected, the software discharge disable
function in the main panel is not available.
* The following devices require a 100kΩ end of line resistor:
Normally open contact Manual Releases
Normally open contact detectors
Discharge Disable Switch (EUEWM-DDS)
* When the THIS heat detector uses the specified Shunt –diode safety barrier, (i.e. for
intrinsically safe applications) select the Barrier command in the System setting.
If
the Barrier setting is not selected and the Shunt –diode safety barrier is used, the
alarm temperature will not be correct and false alarms or failure to alarm may occur.
5.4.5
Zone Selection(SI MODULE→DETECTOR ADRESS→ZONE SELECT)
Selecting zone for each detector. There are 2 zone, zone 1 and zone 2.
D13 ZONE SELECT
ZONE1
▼
Zone Select Display
5.5
Actuator Setting (SYSTEM SETTING→ACTUATOR TYPE)
The Main Panel has 2 actuator outputs. One for solenoids and one for gas cartridge
actuators. Select the appropriate actuator setting.
Solenoids can not be used in combination with gas cartridge actuators.
Actuator Setting Display
ACTUATOR TYPE
ACTUATOR TYPE
GAS CARTRIDGE ▼
SOLENOID VALVE ▼
Gas Cartridge Type
Solenoid Type
16
Installation, Operation, Maintenance Manual
Cabinex-EWT
Control System
04-E-0008
5.5.1
Gas Cartridge Type(ACTUATOR TYPE→GAS CARTRIDGE)
Below is a block diagram for the discharge module and actuator. 1 gas cartridge
actuator connects to 1 discharge module.
Main Panel
Discharge Module (ID
Gas Cartridge Actuator
Discharge Module (ID
Gas Cartridge Actuator
Discharge Module (ID
Gas Cartridge Actuator
Discharge Module (ID
Gas Cartridge Actuator
A maximum of 6 discharge modules can be connected to the Main Panel. (ID
5.5.2
Discharge Module Setting ( ACTUATOR TYPE → GAS CARTRIDGE → D
MODULE)
This module is required for gas cartridge actuators. Do not use this module with
solenoid actuators.
A maximum of 6 discharge modules can be connected to the Main Panel. All 6 address
for the discharge modules must be set ON or OFF as appropriate.
Command
D.MODULE ID: *
(*: 0-5)
Description
Use.
Not use.
ON
OFF
ID Switch (ID: 0-5)
Discharge Module
ACTUATOR (Terminal No. 1,2): For connection to Gas Cartridge Actuator (No polarity)
PRESSURE (Terminal No. 3,4): For connection to normally closed contact of Cylinder
Weighing Device. When the Weighing Device is not
used, short terminals 3, 4 of the Discharge Module.
DC24V (Terminal No. 5, 6): 24V DC output for Cylinder Weighing Device. (Terminal
17
Installation, Operation, Maintenance Manual
Cabinex-EWT
Control System
04-E-0008
Output 0.1A max at 24V DC)
5.5.3
Solenoid Actuator (ACTUATOR TYPE→SOLENOID VALVE)
The solenoid actuator connects directly to the Main Panel. The solenoid output from
the Main Panel is 24V DC, 1A Max.
Main Panel
5.6
Solenoid Actuator
Manual Release (SYSTEM SETTING→MANUAL RELEASE→MODULE)
A maximum of 2 Manual Releases (EUEWM-129) can be connected to the Main Panel.
The 2 address for Manual Release must be set ON or OFF as used.
Manual Release
MR MODULE ID:1
MR MODULE ID:2
Command
ON
OFF
ON
OFF
Description
Use.
Not use.
Use.
Not use.
When 3 or more Manual Releases are required, use normally open contact Manual
Releases and connect to an SI Module (EUEWM-130) .
See 5.5.3 for SI Module System Settings.
5.7
Relay Module (SYSTEM SETTING→RELAY MODULE)
When the Relay Module is plugged into the Main Panel. 4 additional relay contacts can
be used. Each contact is programmable by the Main Panel.
Relay Module
18
Installation, Operation, Maintenance Manual
Cabinex-EWT
Control System
04-E-0008
RELAY
1-4
Command
FIRE ALARM
Pre-DISCHARGE
DISCHARGED
ZONE 1 FIRE
ZONE 2 FIRE
DISABLED
ALARM SILENCED
OFF
Description
Latching
Activate at fire alarm condition.
○
Activate at Pre-Discharge condition ○
Activate at discharged condition.
○
Activate at zone 1 sensor activated. ○
Activate at zone 2 sensor activated. ○
Activate at disable condition.
△
Activate at alarm silenced condition. ×
-
Latching ○:Latches until reset by reset switch.
※
※ Latching ×:Automatically return to Normal condition.
※ Latching △:Latches until set to normal.
RELAY
1
FIRE ALARM ▼
Contact Specification
RELAY 1 Function Display
Contact rating: 60W, 125VA Max.
Maximum voltage: AC250V, DC200V
Maximum current: 1A
The Relay Module cannot be used for additional Fault contact
5.8
Date Setting(SYSTEM SETTING→INPUT DATE)
The Main Panel has a real-time clock. History records the day and time of an event
from this clock.
5.9
Clear Data(CLEAR DATA)
Using this command will clear data. This is only used at the factory.
5.10
View Settings(VIEW SETTING)
The current setting can be check by using the view function. In the case of heat
detector model THIS-15, the current temperature is also displayed in steps of 1℃.
ADDRESS:D23
THIS-100℃
ADDRESS:D23
▼
TEMP. 034 ZONE1
▼
View Display
Detector at Address 23: Heat Detector(THIS)
Alarm Temperature: 100℃
Current Temperature (Approx.): 34℃
19
Installation, Operation, Maintenance Manual
Cabinex-EWT
Control System
04-E-0008
5.11
View History(VIEW HISTORY)
Event history is separated into 2 types; Fire alarm history, All event history. The last
50 events in each type of history can be viewed.
01.03.15.15:30
D21
1/50▼
2001. March 15th 15:30
Detector at address 21: Alarm
Fire Alarm Display
01.03.24.21:44
2001. March 24th 21:44
H11
History Code: H11
1/50▼
※ヒ
All Event History Display
5.12
Buzzer, LED test(LED, BUZZER TEST)
This command is used to check buzzer and LEDs. Selecting this command will cause
each LED to flash in turn and buzzer will sound with each flash.
6. Installation
6.1.1 Wiring
Wiring must be carried out in accordance with all local regulations.
Caution 1 : Check the wiring carefully, as mistaken wiring may damage the equipment.
Caution 2 : Use cable as specified in the table below or equivalent.
20
Installation, Operation, Maintenance Manual
Cabinex-EWT
Control System
04-E-0008
PowerLine:AWG22、
SignalLine:AWG24
メインパネル
MAIN PANEL
NO
NC
C
NO
NC
C
NO
NC
C
NO
NC
C
NO
NC
C
NO
NC
C
火災通報接点
FIRE ALARM RELAY
火災通報接点
FIRE ALARM RELAY
起動通報接点
PRE-DISCHARGE RELAY
起動通報接点
PRE-DISCHARGE RELAY
異常通報接点
FAULT ALARM RELAY
異常通報接点
FAULT ALARM RELAY
未接続
NOT CONNECTED
ソレノイド式起動装置
SOLENOID
ホーンストロボ
HORN&STROBE
マニュアルリリースモ
ジュール
MANUAL RELEASE
MODULE
外部電源出力
DC24V OUTPUT
起動モジュール
DISCHARGE MODULE
+
+
Power +
Power −
COMM +
COMM −
+
−
Power +
Power −
COMM +
COMM −
Power +
SIモジュール
SI MODULE
Power −
COMM +
COMM −
バッテリー入力
Battery Terminal
+
−
+
+
-
0
1
2
20
21
22
3
4
5
23
24
25
6
7
8
26
27
28
9
29
30
31
32
33
34
35
36
37
38
39
10
11
12
13
14
15
16
17
18
19
ケーブル仕様 Cable Specification
接続機器
使用ケーブル
Connected Module
Cable Spec
SIモジュール
DeviceNetCable
SI Module
or RS485 Twisted pair cable
メイン
起動モジュール
DeviceNetCable
パネル
Discharge Module
or RS485 Twisted pair cable
から
DeviceNetCable
マニュアルリリース
Manual Release Module
or RS485 Twisted pair cable
From
ホーンストロボ
ツイストペアシールドケーブル
Main
Horn&Strobe
Twisted pair cable
Panel
バッテリー
ツイストペアシールドケーブル
Battery
Twisted pair cable
ソレノイド式起動装置
ツイストペアシールドケーブル
Solenoid
Twisted pair cable
電線サイズ 最大距離
Wire Size Max Distance
AWG22/24
30m
AWG22/24
30m
AWG22/24
30m
AWG18
30m
AWG18
10m
AWG18
30m
起動モジュール(ガスカートリッジ式起動装置)使用時は
使用しません。
Not Used When Discharge Module is selected
終端抵抗
E.O.L.
3.9KΩ
+
-
接続台数は消費電流により制限
Max Units: 0.5A max
ソレノイド式起動装置
SOLENOID
+
-
1
2
3
4
マニュアルリリースモジュール
MANUAL RELEASE MODULE
ID:1
ホーンストロボ
HORN&STROBE
1
2
3
4
5
6
7
8
マニュアルリリースモジュール
MANUAL RELEASE MODULE
ID:2
7
8
9
10
起動モジュール
DISCHARGE MODULE
ID:0
11
12
13
14
7
8
9
10
起動モジュール
DISCHARGE MODULE
ID:1
Power -
: Black wire
COMM +
:Blue wire
COMM-
:White wire
11
12
13
14
1 SIモジュール D01
2 SI MODULE D02
3
D03
ID:0
4
D04
1
D11
SIモジュール
2 SI MODULE D12
3
D13
ID:1
4
D14
最大8個接続
Max 8 Unit
Caution: Use following color of the DiviceNet Cable
: Red wire
5
6
7
8
最大6個接続 Max 6 Unit
バッテリー
BATTERY
バッテリー
BATTERY 12V
バッテリー
BATTERY 12V
Power +
最大2個接続 Max 2 Unit
Wiring Diagram
21
各種センサー接続
Detectors
Installation, Operation, Maintenance Manual
Cabinex-EWT
Control System
04-E-0008
6.1.2 Earth
All boxes containing the following devices must be connected to Earth:
Main Panel (EUEWM-128, EUEWM-128R)
Manual Release (EUEWM-129)
SI Modules (EUEWM-130)
Discharge Modules (EUEWM-131)
Discharge Disable Switch (EUEWM-DDS)
Main Reserve Switch (EUEWM-MRS)
If the boxes are not connected to earth, the system may false alarm due to electrical
noise and static interference.
6.1.3 Switching the power ON
When powering up the system, switch the power switch on the main panel on before
connecting the battery.
When powering down the system, disconnect the battery then switch the main panel
power switch off.
6.2 Box for External Devices
Each external device should use a specified metal box or equivalent.
7. Battery Calculation
The battery back-up time required depends on each country’s regulations. If there are
no specific guidelines, use 24 hours back-up plus 5 minutes alarm. (NFPA72)
Battery Capacity =(①+②)×1.1
① Total stand-by current (A)×Back-up time (h)
② Total alarm current (A) ×
EQUIPMENT
Main Panel
SI Module
Discharge Module
Relay Module
Manual Release
Horn & Strobe
Flame Detector (HIR-7000)
8.
NORMAL
0.245A
0.055A each
0.045A each
0.042A each
0.015A each
Back-up time(h)
ALARM
0.4A
0.055A each
0.06A each
0.06A each
0.17A each
0.015A each
Maintenance
After installation is complete verify the system operation to the satisfaction of the
22
Installation, Operation, Maintenance Manual
Cabinex-EWT
Control System
04-E-0008
authority having jurisdiction. Regular maintenance must be carried in accordance with
NFPA 72 and by competent trained personnel.
9. Trouble Shooting
9.1 Error Code
Fault
CPU error
AC low
Ground fault
Horn & strobe output disabled
Actuator line disabled
Interlock relay disabled
6 month m aintenance alarm
Module pow er fault
SI module (ID: x) line fault.
Discharge module (ID: x) line fault.
Manual release (ID: x) line fault.
SI module communication error.
Discharge module communication error.
Manual release communication error.
Relay module setting fault
Detector (Address: xx) line open circuit
Detector (Address: xx) line short circuit
Detector (Address: xx) type fault
Cylinder (ID:x) low pressure
Gas cartridge actuator (ID:x) line fault
Horn & strobe line open circuit
Horn & strobe line short circuit
Solenoid line open circuit
Solenoid line short circuit
Battery voltage fault
Battery line open circuit
Blown fuse (DC24V output)
SCROLL switch fault
ENTE R switch fault
SILE NCE switch fault
RESE T switch fault
IP Address Changed
Error code
E00
E01
E02
E03
E04
E05
E06
E10
E11-x
E12-x
E13-x
E14
E15
E16
E17
E20-xx
E21-xx
E22-xx
E30-x
E31-x
E40
E41
E50
E51
E60
E61
E70
E80
E81
E82
E83
E90
Trouble shooting
Change the m ain panel
Check AC supply
Check all line for grounding fault
Set horn & strobe output to norm al
Set actuator output to normal
Set interlocd to normal
6 months since maintenance *1
Check fuse F3 and wiring
Check wiring and adjust ID *2
Check wiring and adjust ID *2
Check wiring and adjust ID *2
Check and adjust ID
*2
Check and adjust ID
*2
Check and adjust ID
*2
Check and reprogram relay module
Check wiring.
Check wiring
Check and reprogram sensor type
Replace cylinder
Check wiring
Check fuse F3 and wiring
Check wiring
Check fuse F1 and wiring
Check wiring
Battery voltage is low
*3
Check wiring
Check and replace F4
Change the m ain panel
Change the m ain panel
Change the m ain panel
Change the m ain panel
Check the IP Address
CAUTION
.
*1
Error code 06 is a maintenance alarm. It is intended to promote regular
maintenance of the system. It does not indicate an actual fault in the system. The
maintenance alarm will occur 6 months after it has been reset. To reset the
maintenance alarm push the reset button for over 5 seconds.
*2
If 2 or more modules have their rotary switches adjusted to the same ID, faults
(E11 to E16) will be displayed. Completely power down the system, and then re-adjust
the ID rotary switches on the modules. After the rotary switches are adjusted, power
23
Installation, Operation, Maintenance Manual
Cabinex-EWT
Control System
04-E-0008
up the system.
Do not adjust the ID rotary switches with the power on, as the system will not read the
new Id.
*3
Battery voltage fault alarm E60
The battery voltage fault alarm will occur if the batteries are disconnected or have
discharged below a useable level.
The internal battery charger can not recharge batteries that have been discharged to
this level. They must be charged by an external lead acid battery charger. A 12V car
battery charger may be used to charge one battery at a time. Replace battery within 5
years after manufacture or more frequently as needed.
24
Installation, Operation, Maintenance Manual
Cabinex-EWT
Control System
04-E-0008
History Code
History code
H00
H01-Dxx
H02-Dxx
H03-Dxx
H04-Dxx
H01-Dxx C
H05
H06
H07
H08
H09
H10
H11
H12
H13
H14
H15
H16
H17
H20
H21
Description
Return to normal condition.
Pre-Alarm 1 (Alarm temperature -30℃.)
Pre-Alarm 2 (Alarm temperature -20℃.)
Pre-Alarm 3 (Alarm temperature -10℃.)
Pre-Alarm 4 (Alarm temperature -5℃.)
Release Pre-Alarm 1
Pre-Discharge condition.
Discharge condition.
Reset switch operated.
Alarm silence switch opreated.
Release Maintenance alarm. (Push reset for 5 seconds)
Delay timer reprogramed.
AND/OR setting reprogramed.
SI module reprogramed.
Discharge module reprogramed.
Manual release reprogramed.
Actuator type reprogramed.
Relay module reprogramed.
Date setting reprogramed.
Checked setting.
Viewed history.
25