8.1 Guaranteed Technical Particulars for Database Server (Intel Based)
(To be filled in manufacturer letterhead pad, otherwise bid will be rejected)
SL
No.
Vendor Response
Name of Item
Technical Specification and Standards
or better)
1
Brand
Should be Internationally Reputed.
2
Model No.
To be mentioned by the Tenderer/Supplier.
3
Country of Origin
To be mentioned by the Tenderer/Supplier.
4
CPU
2 x Intel Xeon Processor E5-2650 8C 2.0GHz
5
Cache
20 MB of Cache
6
Chipset
Intel C602J Chipset
7
Memory
128 GB Registered DDR-3 ECC Memory Upgradeable to 768 GB
Active Memory
Advanced ECC memory protection support, Memory mirroring
8
9
10
protection
Server should have Minimum of 16 x 2.5" Hot Pluggable Hard Disk
Drive Bays
Drive bays (Min 8 Bays Active)
Server should be configured with 4x300GB SAS 15 KRPM 2.5”
Hard Disk Drives
HDD
RAID Controller with 512 MB Battery back cache. The RAID
11
RAID Controller
12
Graphics Controller
Integrated Video Memory 16MB DDR-2 SDRAM
13
Ethernet Adapter
4 x integrated Gigabit Ethernet 1000BASE-T ports (RJ-45)
14
FC HBA
2 x Single Port 8Gb Optical Fibre Channel HBA
15
I/O Expansions
Minimum Six Number of PCIe Slots
16
Power Supply
Dual Redundant Hot Swappable Power Supplies
Hot Swap/Redundant
Server should be configured with Hot Swap Fans
17
controller should support Raid 0, 1, 5, 10, 50.
Fans
The server should be able to alert impending failures on maximum
18
Failure Alerting
number of components. The components covered under alerting
Mechanism
mechanism should at least include Processors, memory, voltage
regulator modules (VRMs), power supplies and fans
Server should send an alert notification on the system front panel
19
(May propose equal
Ease of failure
identification
for failure of any component like Processors, voltage regulator
modules (VRMs),memory, power supplies, fans, HDDs, adapters
and system temperature which will allow system administrator to
identify the component failure
8-2
SL
No.
Vendor Response
Name of Item
Technical Specification and Standards
or better)
20
Form Factor
2U
21
System Software
OEM Server Management software with the device drivers
Operating System
Microsoft Windows 2008 Server, RedHat Enterprise Linux, SUSE
Support
Linux Enterprise Server 10 and 11, VMware vSphere 5
23
Operating System
To be mentioned by the Tenderer/Supplier.
24
RDBMS
To be mentioned by the Tenderer/Supplier.
25
Warranty
At least 3 years on site with full labour, parts & replacement.
22
(May propose equal
Seal & Signature of the Manufacturer
Seal & Signature of the Bidder
8-3
8.2 Guaranteed Technical Particulars for Application Server
(To be filled in manufacturer letterhead pad, otherwise bid will be rejected)
Vendor Response
SL No.
Name of Item
Technical Specification and Standards
(May propose equal
or better)
1
Brand
Should be Internationally Reputed
2
Model No.
To be mentioned by the Tenderer/Supplier.
3
Country of Origin
To be mentioned by the Tenderer/Supplier.
4
CPU
2 x Intel Xeon Processor E5-2650 8C 2.0GHz
5
Cache
20 MB of Cache
6
Chipset
Intel C602J Chipset
7
Memory
8
9
10
11
12
13
Active Memory protection
64GB Registered DDR-3 ECC Memory Upgradeable to
768 GB
Advanced ECC memory protection support, Memory
mirroring
Drive Bays
Server should have Minimum of 16 x 2.5" Hot Pluggable
Hard Disk Drive bays (Min 8 Bays Active)
Hard Disk Drives
Server should be configured with 4x300GB SAS 15
KRPM 2.5” HDD
RAID Controller
RAID Controller with 512 MB Battery back cache. The
RAID controller should support Raid 0, 1, 5, 10, 50.
Graphics Controller
Integrated Video Memory 16MB DDR-2 SDRAM
Ethernet Adapter
4 x integrated Gigabit Ethernet 1000BASE-T ports (RJ45)
14
I/O Expansions
Minimum Six Number of PCIe Slots
15
Power Supply
Dual Redundant Hot Swappable Power Supplies
16
Hot Swap/Redundant Fans
Server should be configured with Hot Swap Fans
Failure Alerting Mechanism
The server should be able to alert impending failures on
maximum number of components. The components
17
covered under alerting mechanism should at least
include Processors, memory, voltage regulator modules
(VRMs), power supplies and fans
Ease of failure identification
18
Server should send an alert notification on the system
front pannel for failure of any component like Processors,
voltage regulator modules (VRMs),memory, power
supplies, fans, HDDs, adapters and system temperature
8-4
Vendor Response
SL No.
Name of Item
Technical Specification and Standards
(May propose equal
or better)
which will allow system administrator to identify the
component failure
19
20
Form Factor
2U
OEM Server Management software with the device
System Software
drivers
Microsoft Windows 2008 Server, RedHat Enterprise
21
Operating System Support
Linux, SUSE Linux Enterprise Server 10 and 11, VMware
vSphere 5
22
Operating System
23
Warranty
Windows 2012 Server Standard Edition with License and
Media
At least 3 years on site with full labour, parts &
replacement.
Seal & Signature of the Manufacturer
Seal & Signature of the Bidder
8-5
8.3 Guaranteed Technical Particulars for Backup Management Server
(To be filled in manufacturer letterhead pad, otherwise bid will be rejected)
Vendor Response
SL No.
Name of Item
Technical Specification and Standards
(May propose equall
or better)
1
Brand
Should be Internationally Reputed.
2
Model No.
To be mentioned by the Tenderer/Supplier.
3
Country of Origin
To be mentioned by the Tenderer/Supplier.
4
CPU
5
Cache
15 MB of Cache
6
Chipset
Intel C602J Chipset
7
Memory
32 GB Registered DDR-3 ECC Memory Upgradeable to 768 GB
Active Memory
Advanced ECC memory protection support, Memory mirroring
8
9
10
1 x Intel Xeon Processor E5-2640 6C 2.5GHz 15MB Cache
1333MHz 95W
protection
Drive Bays
Server should have Minimum of 16 x 2.5" Hot Pluggable Hard
Disk Drive bays (Min 8 Bays Active)
Server should be configured with 3x300GB SAS 15 KRPM 2.5”
Hard Disk Drives
HDD
RAID Controller with 512 MB Battery back cache. The RAID
11
RAID Controller
12
Graphics Controller
Integrated Video Memory 16MB DDR-2 SDRAM
Ethernet Adapter
Quad-port with TCP/IP Offload Engine (TOE), Wake on LAN,
13
controller should support Raid 0, 1, 5, 10, 50.
Serial over LAN , PXE 2
14
FC HBA
2 x Single Port 8Gb Optical Fibre Channel HBA
15
I/O Expansions
Minimum Six Number of PCIe Slots
16
Power Supply
Dual Redundant Hot Swappable Power Supplies
Hot Swap/Redundant
Server should be configured with Hot Swap Fans
17
Fans
The server should be able to alert impending failures on maximum
18
Failure Alerting
number of components. The components covered under alerting
Mechanism
mechanism should at least include Processors, memory, voltage
regulator modules (VRMs), power supplies and fans
19
Ease of failure
identification
Server should send an alert notification on the system front pannel
for failure of any component like Processors, voltage regulator
modules (VRMs),memory, power supplies, fans, HDDs, adapters
8-6
Vendor Response
SL No.
Name of Item
Technical Specification and Standards
(May propose equall
or better)
and system temperature which will allow system administrator to
identify the component failure
20
Form Factor
2U
21
System Software
OEM Server Management software with the device drivers
Operating System
Microsoft Windows 2008 Server, RedHat Enterprise Linux, SUSE
Support
Linux Enterprise Server 10 and 11, VMware vSphere 5
23
Operating System
Windows 2012 Server Standard Edition with License and Media
24
Warranty
At least 3 years on site with full labour, parts & replacement.
22
Seal & Signature of the Manufacturer
Seal & Signature of the Bidder
8-7
8.4 Guaranteed Technical Particulars for External Storage
(To be filled in manufacturer letterhead pad, otherwise bid will be rejected)
Vendor Response
SL No.
Name of Item
Technical Specification and Standards
(May propose equal
or better)
1
Brand
SUN/IBM/EMC
2
Model
To be mentioned by the Tenderer/Supplier.
3
Country of Origin
To be mentioned by the Tenderer/Supplier.
4
Node Type
Rack Mountable with slide rails rack kit.
Array should be configured with Active/Active Dual Controllers for
5
Architecture
redundancy supporting 8Gbps FC and 1Gbps iSCSI host interface
with embedded storage virtualization capability to attach external
vendor neutral disk systems.
6
Rack Mounted
The SAN storage must be rack mounted
It should support all industry leading operating systems including
7
OS & Clustering Support
Windows NT, 2000, 2003, 2008, AIX, HP-UX, Solaris, Redhat linux,
Open VMS, IBM i OS, Apple Mac OS X, etc. The list of supported
operating systems should be provided.
The proposed storage device should be scalable to at least 480
Drives supported with same SAS/FC and NL SAS/SATA spindle
8
Disk Scalability
types. The scalability of the drives can be achieved using
virtualization capability to attach vendor neutral external disk system.
Such Virtualization capability should be inherently architected and
configured from the day one.
The storage array should be configured with 3TB Usable space after
9
Capacity Requirements RAID 1+0 using 300 GB 6Gbps SAS/4Gbps FC Drives and 2TB
Usable space after RAID5 using 1TB NLSAS HDD.
The Storage array should support Global Hot Spare (HS) Disks. A
17
Hot Spare Disks
minimum of 1 global hot spare per disk type and per disk enclosure
should be supplied and configured.
10
Intermix of Disks
The storage should support an intermix of SSD, SAS/FC and NL
SAS/SATA disks and 2.5" and 3.5" form factor drives.
It should be configured with at-least 8 numbers of 8Gbps front end
11
Front End Ports
Fiber Channel ports across Dual controllers or an aggregate host
bandwidth of minimum 64Gbps and 4 numbers of 1Gbps iSCSI
interface.
8-8
Vendor Response
SL No.
Name of Item
Technical Specification and Standards
(May propose equal
or better)
It should be configured with at-least 4 numbers of 6Gbps SAS/FC
12
Back End Connectivity
backend ports across Dual controllers towards disks with the ability
to ensure no data loss in the event of failure of any one of the
controller.
Dual Controllers with minimum 8GB cache per controller or 16 GB
13
Storage Controller
per storage system. Cache should be mirrored across controller.
Upgradeable option up to 32 GB.
14
RAID
The Storage array should support Controller based RAID Levels: 0,
1, 5, 6 and 1+0
It should provision for Redundancy of critical units like processor,
disk drives, controllers, fan, Power supply etc. and non-disruptive
15
No Single point of failure
online micro-code upgrades in order to ensure no single point of
failure.
It should support hot plugging and hot swapping of critical
components with minimal disruption.
In case of power failure, system should ensure that there is no loss
16
Cache Data Backup in
of data and battery backup for cache should be provided. Also the
Power Failure
data should be de-staged to internal flash or disk drives for higher
protection of data.
18
Dynamic LUN expansion Must support on-line dynamic expansion of LUNs
19
LUN Support
The storage device should support 2048 LUN's
The Storage System should support Tiering of Data at LUN and Sub
20
Tiering
21
Thin Provisioning
22
Host support
LUN level for higher performance required out of SSD drives.
The Storage System should be configured Thin Provisioning for
better utilization of unused capacity.
Please Mention
The Storage System should be provided with intuitive Web Based
23
Management Software
GUI interface to manage architectural configuration and embedded
graphical performance monitoring.
24
25
Multi pathing Driver
Multi pathing driver should be provided along with the storage device
for the maximum nos. of supported host connectivity.
PiT Snapshots & Full
Should be configured with point in time snapshots, full volume copy.
Copy
Up to 250 such snapshots per volume should be possible. It should
8-9
Vendor Response
SL No.
Name of Item
Technical Specification and Standards
(May propose equal
or better)
be possible to create the copies in a different disk array/system using
virtualization capability.
- Should support incremental copy capability – where only changes
from the source are copied during a target refresh
- Should support cascaded copy capability – i.e. capability to create
“copies of copies”. Mappings may be incremental or non-incremental
- Should have the capability to reverse relationships instantly to
enable rapid data recovery.
26
Virtualization Capability Please mention
Replication software should be provided for data replication across
metro and global distances for disaster recovery. Replication
27
Replication
software should support synchronous as well as asynchronous
replication having Unlimited license for full capacity use of Disk
Enclosure.
28
Warranty
At least 3 years on site with full labour, parts & replacement.
Seal & Signature of the Manufacturer
Seal & Signature of the Bidder
8 - 10
8.5 Guaranteed Technical Particulars for Storage Area Network (SAN) Switch
(To be filled in manufacturer letterhead pad, otherwise bid will be rejected)
SL No.
Name of Item
Technical Specification and Standards
Vendor Response
(May propose
equal or better)
1
Brand
Should be internationally reputed
2
Model
To be mentioned by the Tenderer/Supplier.
3
Country of Origin
To be mentioned by the Tenderer/Supplier.
4
Country of Manufacturing
To be mentioned by the Tenderer/Supplier.
5
Form Factor
19 (nineteen) inch rack mountable, please specify rack unit
Number of ports
Fourteen (16) 8Gbps SW SFP Transceiver and upgradeable
6
up to 24 Ports
Port Bandwidth
7
At least 8 (Eight) Gbps auto-sensing Fiber Channel ports
must support the following port types: (E, F and FL) with
SFP/LC optical interfaces.
Aggregate Device Bandwidth
8
The switch should have Non-blocking architecture designed
to provide up to 384 Gbps aggregate throughput with a 24port configuration
9
10
11
12
13
14
Redundant Components
Please specify if any
Hot Pluggable/ Swappable
Please specify if any
Components
High Availability
Hot code activation, single field replaceable unit etc.
required – please specify
Security Features
Please specify
Manageability
Web Tools required;
Please specify others
Software
Please specify the features of all the software in details
– All the software have to be licensed for unlimited users
15
Peripherals and Accessories
All required peripherals and accessories
16
Other Features
Please mention, if any
17
Warranty
At least 3 years on site with full labour, parts & replacement.
Seal & Signature of the Manufacturer
Seal & Signature of the Bidder
8 - 11
8.6 Guaranteed Technical Particulars for Multiprotocol Router Switch
(To be filled in manufacturer letterhead pad, otherwise bid will be rejected)
SL No.
Name of Item
Technical Specification and Standards
Vendor Response
(May propose
equal or better)
1
Brand
Should be internationally reputed
2
Model No.
To be mentioned by the Tenderer/Supplier.
3
Chassis
To be mentioned by the Tenderer/Supplier.
4
Fibre Channel interface
For FC: E_Port, EX: Port, F_Port, EL Port, M Port, U Port
For FCIP: VE _Port (virtual E_Port)
5
Optical transceivers
4 X 8Gbps SFP Transceiver and can be upgradable up to 16
Fibre Ports
6
Copper transceiver
2 X 1GbE SFP Transceiver and can be upgradable up to 6
Ethernet Ports
7
Fan And Power Supply
Redundant power supply/dual-fan modules
8
Management and
Switch shall have integrated Ethernet and Serial port for
communication port
management & communication.
9
Country of origin
Should be mentioned.
10
Country of Assemble
Should be mentioned
11
Warranty
At least 3 years on site with full labour, parts & replacement.
Seal & Signature of the Manufacturer
Seal & Signature of the Bidder
8 - 12
8.7 Guaranteed Technical Particulars for Tape Library
(To be filled in manufacturer letterhead pad, otherwise bid will be rejected)
SL No.
Name of Item
Technical Specification and Standards
Vendor Response
(May propose equal
or better)
1
Brand
Should be mentioned
2
Model No.
Should be mentioned
3
Country of origin
Should be mentioned.
4
Chassis
Rack mount with rack kit
5
Tape Device Type
LTO Ultrium 6 Tape Library
6
Interface
FC (8Gbps) Native Interface
7
Network interface
Ethernet(RJ-45)
8
Number of Drive
1 (One)
9
Minimum throughput
At least 160MB/S
10
Cartridges Slots
At least Twenty Four ( 24 )
11
Library Capacity
60 TB native with LTO Ultrium 6 ( without compression )
12
Hot Swap feature
Power Supply should be hot swappable
13
Remote Management feature
Remote web-based management and SMI-S interface capable
14
Tape Cartridges
As required
15
Mixed Tape
Must support mix tape drive technology and mix media such in
same library as LTO4, LTO5 & LTO6.
16
Power Supply
Redundant Power Supply
17
Operating system
Should be mentioned.
18
Cartridge
Twenty (20) LTO6 labeled Data cartridges and Two (2)
Cleaning Cartridge.
19
Warranty
At least 3 years on site with full labour, parts & replacement.
Seal & Signature of the Manufacturer
Seal & Signature of the Bidder
8 - 13
8.7.1 Guaranteed Technical Particulars for Tape Backup Software
(To be filled in manufacturer letterhead pad, otherwise bid will be rejected)
SL NO
1
Backup Software Specifications
The Backup Software should support all major releases of MS Windows & Linux on the
available platforms.
2
The Backup Software must support disk based backups.
3
The Backup software must provide Block level backup of the data.
4
5
6
7
The Backup software must support continuous, snapshot and scheduled backups of the
Client systems. The required license must be provided as a part of the solution.
The Backup software must support SAN based backup (LAN free to disk) backups.
The Backup Software must support snapshot backup of applications like MS Exchange, Lotus
Domino, Oracle and DB2 etc.
The Backup Software should support role based access for manageability (i.e Administrator
level, user level)
The Backup software must provide the granularity for file level and Full data set level
8
restoration of data. Additionally for email and database systems, it must support the
respective, email level and database table level recovery.
9
10
The Backup software must have Bare Machine Restore capability. The required licenses
need to propose as a part of the solution.
The Backup software should capable to provide tape integration for long term retention of the
backed up data.
11
Backup software should support open file backup
12
Should support email alerting
13
Backup software should be capable to replicate the backed up data to DR site
14
The solution should give the provision of compression while taking backup
15
16
17
18
It should enable near zero data loss recovery of Mail, Applications & Database servers
without the need for constant replication or synchronization
The software should have a disaster recovery system in place to protect the data in case of
possible disaster
It should provide details of alerts/errors in the user interface along with detailed error
description and possible resolution.
Solution should provide for one single full backup in lifetime. Should provide forever
incremental full backup with single attempt recovery
19
The solution should be able to recover files in minutes instead of hours
20
The backup of data should be continuous and not limited to a certain backup window
8 - 14
Vendor Response (May
propose equal or better)
SL NO
21
22
Vendor Response (May
Backup Software Specifications
propose equal or better)
The solution should be capable of minimizing potential data loss from 24 hours to near zero
Proposed Backup Solution Should be configured for all proposed Database and Application
Servers at Data Center
Seal & Signature of the Manufacturer
Seal & Signature of the Bidder
8 - 15
8.8 Guaranteed Technical Particulars for Desktop PC Specification for Application Users
(To be filled in manufacturer letterhead pad, otherwise bid will be rejected)
SL No.
Name of Item
Technical Specification and Standards
1
2
3
Brand
Model
Country of Origin
To be mentioned by the Tenderer/Supplier
To be mentioned by the Tenderer/Supplier
To be mentioned by the Tenderer/Supplier
4
Country of Manufacturer
To be mentioned by the Tenderer/Supplier
5
6
7
8
9
10
Casing
Processor
Clock Speed
Front Side Bus
Level 2 Cache
Chipset
11
RAM
12
13
14
15
Memory slot
Graphics
HDD
Expansion Slot
16
I/O Connector
17
Monitor
18
19
20
21
22
23
Key Board
Mouse & PAD
Optical Drive
Network Card
Sound Card & Speaker
Operating System
24
Software
25
26
Certification
Warranty
Tower
Intel® Core™ i5
Min 3.2 GHz or Higher
1333 MHz
6 MB
Intel H67 or higher Express Chipset, Bus speed : 1333
MHz
4GB DDR3 (1333-MHz) SDRAM upgradable up to
16GB
2 DIMM's
Integrated Intel HD graphics
Min. 500 GB SATA, 7200 RPM
One (1) full-height PCI Express x1 slots on PCA, One
(1) full-height PCI Express x16 slot on PCA (for graphic
cards), Two (2) full-height PCI slots on PCA
Rear I/O includes (4) USB 3.0 and (2) USB 2.0 ports,
serial RS232 port, PS/2 mouse and keyboard ports, RJ45 network interface, One (1) DVI-D video port and
VGA video interfaces, and 3.5mm audio in/out jacks,
Front I/O includes (4) USB 2.0 ports, dedicated
headphone output, and a microphone/headphone jack
18.5” W-LED Color Monitor (same Brand and color of
system unit)
USB Standard Keyboard
USB Standard optical Mouse with mouse pad
16X DVD RW
Integrated gigabit (10/100/1000) Ethernet
Integrated sound card and speaker.
Genuine Windows 7 Professional with Original License
and recovery CD/Drive
(i) Licensed bangla software preferably Lekhoney
(ii) Licensed Anti Virus Software preferably
Kesperesky/Norton /Semantic
FCC Class B, ISO 9001: 2000
3 (Three) years warranty with parts and labour
Seal & Signature of the Manufacturer
Vendor Response (May
propose equal or better)
Seal & Signature of the Bidder
8 - 16
8.9 Guaranteed Technical Particulars for Laser Printer
(To be filled in manufacturer letterhead pad, otherwise bid will be rejected)
Name of Item
Sl. No.
Technical Specification and Standards
1
2
3
Brand
Model
Country of Origin
To be mentioned by the Tenderer/Supplier.
To be mentioned by the Tenderer/Supplier.
To be mentioned by the Tenderer/Supplier.
4
Country of Manufacturing
To be mentioned by the Tenderer/Supplier.
5
6
7
8
9
10
11
12
13
14
15
16
Paper Size
Processor
Speed
First Page Out
Printer Resolution
Toner type
Fuser Unit
Special Feature
Duty Cycle
Interface
RAM
Duplex Printing
A4 / Letter/ Legal
Min 800 MHz or higher
Min 33 PPM or higher
Less than 9 seconds from Sleep mode
Min 1200X1200 dpi
Printer with a standard capacity cartridges at least 2000
pages
(supported with
by brochure)
Instantcoverage
on fuser technology
ceramic heating elements.
Save energy with Auto-On/Auto-Off Technology
At least 50000 Pages per month
Hi Speed USB 2.0 Port
Min 128 MB or higher
Automatic Two side Printing capacity (Auto Duplex)
17
Tray
Input : 50 Sheet multipurpose tray-1, 250 sheets input tray-2;
Vendor Response (May
propose equal or better)
Out Put: 125-sheet
18
19
Accessories
Certification
Printer Cable, Power Cord, Driver Software CD
ISO-9000
20
21
22
Toner Life, No of Copies
Drum Life, No of Copies
Warranty
To be mentioned by the Tenderer/Supplier.
To be mentioned by the Tenderer/Supplier.
1 (one) year warranty with parts and labour
Seal & Signature of the Manufacturer
Seal & Signature of the Bidder
8 - 17
8.10.1 Guaranteed Technical Particulars for Online UPS
(To be filled in manufacturer letterhead pad, otherwise bid will be rejected)
Sl No
Item
1
Brand
2
3
4
Model
Country of origin
Country of
manufacture
Capacity
Transfer time
Input Voltage
Input Frequency
Output Voltage
Technology
Output Frequency
Output Waveform
Phase
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
Power Factor
Battery
Recharging
Battery Type
Efficiency
Noise
Backup Time
SNMP device/
Remote Network
Interface
Warranty
Required specification
Vendor Response (May propose
equal or better)
Any International reputed brand
preferably APC/Socomec/MGE/Riello
To be mentioned by the bidder
North America/ EU / Japan
To be mentioned by the bidder
Min. 10 kVA
0 mili sec
400- 425 V AC
50/60 Hz ± 5 Hz
220-230-240 Vac selectable
Double Conversion
50/60 Hz selectable
Sinewave
Input Three Phase
Output Single Phase
> 0.98
4-6 hr
Maintenance-free sealed lead-acid
up to 98%
< 45 dBA at 1 m
02 hours at full load
Included with software
Full 03 years for UPS and 01 year for
battery replacement and onsite service
warranty for both.
Seal & Signature of the Manufacturer
Seal & Signature of the Bidder
8 - 18
8.10.2 Guaranteed Technical Particulars for Online UPS
(To be filled in manufacturer letterhead pad, otherwise bid will be rejected)
Sl No
Item
1
Brand
2
3
4
Model
Country of origin
Country of
manufacture
Capacity
Transfer time
Input Voltage
Input Frequency
Output Voltage
Technology
Output Frequency
Output Waveform
Phase
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
Power Factor
Battery
Recharging
Battery Type
Efficiency
Noise
Backup Time
SNMP device/
Remote Network
Interface
Warranty
Required specification
Vendor Response (May propose
equal or better)
Any International reputed brand
preferably APC/Socomec/MGE/Riello
To be mentioned by the bidder
North America/ EU / Japan
To be mentioned by the bidder
Min. 1 kVA
0 mili sec
220-230-240 Vac
50/60 Hz ± 5 Hz
220-230-240 Vac selectable
Double Conversion
50/60 Hz selectable
Sinewave
Input Single Phase
Output Single Phase
> 0.98
4-6 hr
Maintenance-free sealed lead-acid
up to 98%
< 45 dBA at 1 m
01 hours at full load
Included with software
Full 03 years for UPS and 01 year for
battery replacement and onsite
service warranty for both.
Seal & Signature of the Manufacturer
Seal & Signature of the Bidder
8 - 19
8.10.3 Guaranteed Technical Particulars for Offline UPS
(To be filled in manufacturer letterhead pad, otherwise bid will be rejected)
Sl No
Item
1
2
3
4
5
6
7
8
9
Brand
Model
Country of origin
Country of manufacturer
Capacity
Input Voltage
Output Voltage
Input Frequency
Battery Recharge Time
10
11
12
13
14
Battery Maintenance
Back Up Time
Transfer Time
Wave form (Inverter)
AC input Cable
15
16
UPS off mode
Power Strip
17
Protection
18
Features
19
Warranty
Required specification
To be mention by the bidder
To be mention by the bidder
To be mention by the bidder
To be mention by the bidder
Min 1000 VA
160-270 V AC
220+/-5%
50 Hz
Recharge Time 8 Hours To 90% After Full
Discharge
Sealed Maintenance Free
15 Minutes at Full Load.
Less than 2 Mili Sec.
: Stepped Wave Synchronize
High quality a/c cable with fuse protected
grounded 13A/15A plug.
Battery charging on.
4 to 6 points x 3 Pin (Universal Options, Foreign
made)
Lightning, Transients, Spike, Sag, Surge,
Blackout,
Brownout, Flicker, Over Voltage,
Under Voltage, Over Load, Short circuit, Battery
Over Charge, Battery Low (Deep Discharge)
& noise (EMI & RFI) as per international safety
practices
i) Relay Control
ii) Built in wide range Automatic Voltage
Stabilizer
1 (one) year full warranty (with Battery)
Seal & Signature of the Manufacturer
Seal & Signature of the Bidder
8 - 20
Vendor
Response (May
propose equal or
better)
8.11 Guaranteed Technical Particulars for Slip Printer
(To be filled in manufacturer letterhead pad, otherwise bid will be rejected)
Sl No
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Description
Specification Requirement
Brand Model
Model
Country of Origin
Country of manufacturer
Print method
Print font
Column capacity
Character per inch
Interfaces
Print speed
Paper
Copy capability
Ribbon life
Warranty
Internationally Reputed brand
To be mentioned by the bidder
To be mentioned by the bidder
To be mentioned by the bidder
9 pin, dot Matrix
7x9 or 9x9
40/42 or 33/35
17.8/16 or 14.5/13.3
RS 232, bidirectional parallel or USB
4.7 lps at 16 cpi, 40 column
Roll paper
one original, one copy
Min. black 3x10000000 characters
1 (one) year warranty with parts and labour
Seal & Signature of the Manufacturer
Vendor Response (May
propose equal or better)
Seal & Signature of the Bidder
8 - 21
8.12.1 Guaranteed Technical Particulars for Close Rack
(To be filled in manufacturer letterhead pad, otherwise bid will be rejected)
SL. No.
Name of Item
Technical Specification and Standards
2
Brand
Same Brand as offered Server
3
Model
Please mention
4
Country of Origin
Please mention
5
Country of Assemble
Please mention
6
Height
42U EIA Closed Rack
Capacity
19” X 73” X 1000 mm (minimum) with:
Vendor Response (May
propose equal or better)
i) All door locks
7
ii) Caster wheel
iii) Cage nuts & screws
iv) Extension bars
8
9
10
Rack Monitor
17” TFT rack mount monitor in 1U rack space 1 unit and
slides independently of the keyboard and touchpad
Integrated Keyboard and Mouse
Required with sliding functionality
Power Distribution Unit (PDU)
Power Distribution Unit (PDU)
9 way, 2 units to support for each rack
KVM Switch
11
Rack Mountable Switch that allows users single-point
access and control of up to 8 multiple servers from a
single console along with necessary cables
12
Warranty
At least 3 years on site with full labour, parts &
replacement.
Seal & Signature of the Manufacturer
Seal & Signature of the Bidder
8 - 22
8.12.2 Guaranteed Technical Particulars for Close Rack
(To be filled in manufacturer letterhead pad, otherwise bid will be rejected)
SL. No.
Name of Item
Technical Specification and Standards
2
Brand
Same Brand as offered Server
3
Model
Please mention
4
Country of Origin
Please mention
5
Country of Assemble
Please mention
6
Height
18U Closed Network Cabinet
7
Capacity
19” X 73” X 1000 mm (minimum) with:
Vendor Response (May
propose equal or better)
iv) All door locks
ii) Caster wheel
iii) Cage nuts & screws
iv) Extension bars
8
Power Distribution Unit (PDU)
Power Distribution Unit (PDU)
One 7 port UK Standard PDU to support for each Rack.
9
Warranty
At least 3 years on site with full labour, parts &
replacement.
Seal & Signature of the Manufacturer
Seal & Signature of the Bidder
8 - 23
8.13 Guaranteed Technical Particulars for Load Balancer
(To be filled in manufacturer letterhead pad, otherwise bid will be rejected)
SL No.
1
Name of Item
Technical Specification and Standards
Brand
Should be Internationally reputed.
Model
Should be mentioned
Part/Product No.
Should be mentioned
Country of origin
Should be mentioned.
Country of Assemble
Should be mentioned.
Chassis
1RU appliance
General Features and
Network Port: Four 10/100/1000 Ethernet ports
Performance
Throughput: .5 Gbps
Virtual contexts: 20
SSL throughput: 1 Gbps
SSL TPS: 7500 SSL TPS using 1024-bit keys
Maximum L4 connections per second: 100,000 complete
transactions sustained rate
Maximum L7 connections per second: 30,000 complete
transactions sustained rate
Concurrent connections: 1 million
Flash memory: 1 GB
Availability
Application switching: The appliance should provide loadbalancing and content-switching functions with granular
traffic control based on customizable Layer 4 through 7
rules with support for both IPv4 and IPv6 addresses,
virtual IP addresses (VIPs) and server farms.
Predictors: Predictors or load-balancing algorithms enable
the appliance to select the best server to satisfy a client
request.
Server health monitoring: The appliance checks the health
of application servers and server farms through
configuration of health probes.
Security
Data center security: The appliance should protect the
data center and critical applications from protocol and
denial-of-service (DoS) attacks and encrypts missioncritical content.
Application security: The appliance should provide deep
protocol inspection capabilities, which enables IT
professionals to comprehensively secure high-value
8 - 24
Vendor Response (May
propose equal or
better)
SL No.
Name of Item
Technical Specification and Standards
Vendor Response (May
propose equal or
better)
applications in the data center. It secures mission-critical
applications and protects against identity theft, data theft,
application disruption, and fraud and defends web-based
applications and transactions against targeted attacks by
professional hackers.
Management
Embedded browser-based GUI and SNMP
Maximum power
345W
Warranty
Three years Warranty
Seal & Signature of the Manufacturer
Seal & Signature of the Bidder
8 - 25
8.14 Guaranteed Technical Particulars for Router
(To be filled in manufacturer letterhead pad, otherwise bid will be rejected)
Vendor Response (May
SL No.
Name of Item
Technical Specification and Standards
propose equal or
better)
1
Brand
CISCO
2
Model
3945E-sec/k9 or Higher
3
Part/Product No.
Should be mentioned
4
Country of origin
Should be mentioned.
5
Country of Assemble
Should be mentioned.
6
General Features and
The Router should support Data, Voice, video
Performance
The Router should have total number of onboard
ports(10/100/1000) RJ-45: 04
Should have two 10/100 Routed port from day 1.
SFP-based ports : 02
Service Module Slots: 04
EHWIC Slots: 03
Number of Double-Wide EHWIC slots: 01
Onboard DSP (PVDM) Slots:03
Embedded Hardware-Based Cryptography and
Acceleration (IPSec + SSL).
Performance should be minimum 2900 kpps (64-byte
packets) and minimum 8500 Mbps (1500-byte packets)
Number of concurrent sessions (1000s) 345
WAN Circuit Speed (Mbps): 350
Should have on board VPN acceleration mechanism and
VPN features from Day 1
IP private-branch-exchange (PBX) and key-system
features should support for future
Number of USB console port:01
Number of Serial console ports: 01
Number of auxiliary ports: 01
External USB 2.0 Flash Memory slots:02
Compact Flash: 256 MB(Minimum) support up to 8 GB
DRAM: 1 GB (Minimum) support up to 2 GB
7
Protocols:
IPv4, IPv6, Static Routes, Open Shortest Path First
(OSPF), Enhanced IGRP (EIGRP), Border Gateway
Protocol (BGP), BGP Router Reflector, Intermediate
System-to-Intermediate System (IS-IS), Multicast Internet
8 - 26
Vendor Response (May
SL No.
Name of Item
Technical Specification and Standards
propose equal or
better)
Group Management Protocol (IGMPv3) Protocol
Independent Multicast sparse mode (PIM SM), PIM
Source Specific Multicast (SSM), Distance Vector
Multicast Routing Protocol (DVMRP), IPSec, Generic
Routing Encapsulation (GRE), Bi-Directional Forwarding
Detection (BVD), IPv4-to-IPv6 Multicast, MPLS, L2TPv3,
802.1ag, 802.3ah, L2 and L3 VPN
8
Encapsulation:
Ethernet, 802.1q VLAN, Point-to-Point Protocol (PPP),
Multilink Point-to-Point Protocol (MLPPP), Frame Relay,
Multilink Frame Relay (MLFR) (FR.15 and FR.16), HighLevel Data Link Control (HDLC), Serial (RS-232, RS-449,
X.21, V.35, and EIA-530), Point-to-Point Protocol over
Ethernet (PPPoE), and ATM
9
Traffic management:
QoS, Class-Based Weighted Fair Queuing (CBWFQ),
Weighted Random Early Detection (WRED), Hierarchical
QoS, Policy-Based Routing (PBR), Performance Routing,
and NBAR.
10
Power Specifications
AC input voltage: 100-240 VAC
AC input frequency: 47-63 Hz
Should have Redundant Power supply from day 1
Maximum Power capacity with AC power supply: 540
Watts
11
Environmental
Temperature: 5906 ft (1800m) maximum altitude : 32 to
specifications
104ºF(0 to 40ºC)
Operating conditions
Temperature: 9843 ft (3000m) maximum altitude: 32 to
104ºF
(0 to 40ºC)
Temperature: 13123 ft (4000m) maximum altitude: 32 to
86ºF
(0 to 30ºC)
12
Regulatory and
Safety:
Compliance:
UL 60950-1
CAN/CSA C22.2 No. 60950-1
EN 60950-1
AS/NZS 60950-1
IEC 60950-1
EMC:
8 - 27
Vendor Response (May
SL No.
Name of Item
Technical Specification and Standards
propose equal or
better)
47 CFR, Part 15
ICES-003 Class A
EN55022 Class A
CISPR22 Class A
AS/NZS 3548 Class A
VCCI V-3
CNS 13438
EN 300-386
EN 61000 (Immunity)
EN 55024, CISPR 24
EN50082-1
13
Warranty
Three years Warranty
Seal & Signature of the Manufacturer
Seal & Signature of the Bidder
8 - 28
8.15 Guaranteed Technical Particulars for Firewall
(To be filled in manufacturer letterhead pad, otherwise bid will be rejected)
SL No.
Name of Item
Technical Specification and Standards
1
Brand
CISCO
2
Model
ASA5545X-k9 or Higher
3
Part/Product No.
Should be mentioned
4
Country of origin
Should be mentioned.
5
Country of Assemble
Should be mentioned.
6
Form Factor
1 RU, 19-in rack mountable
7
General Features and
The Firewall should be an appliance based firewall integrated
Performance
with full-featured, high-performance security services.
Firewall throughput: 3 Gbps
Real-world firewall throughput: 1.5 Gbps
Maximum firewall connection: 750000
Maximum firewall connection/second: 30000
IPS throughput (supported): 900 Mbps
3DES/AES VPN throughput: 400 Mbps
VLANS: 300
IPsec VPN Peers: 2500
Security Contexts (Included/Maximum): 2/50
High Availability: Active/Active and Active /Standby
Expansion Slot: 1 interface card
Integrated interface: 8 GE copper
Memory: 12 GB
Flash: 8 GB
System Bus: Multibus architecture
The Firewall should support Layer 2 (Transparent) mode.
Firewall should support static NAT, Policy based NAT and
PAT.
Firewall should be capable of Dynamic routing on VPN.
Firewall should support client based IPSec VPN Tunnels.
Support for Remote Authentication Dial-In User Service
(RADIUS) and AAA and Terminal Access Controller Access
Control System Plus (TACACS+)
8
Temperature
23 to 104°F (-5 to 40°C)
9
Power (AC Range Line
100 to 240 VAC and should have redundant power supply
Voltage)
from day 1.
Warranty
Three years Warranty
10
Seal & Signature of the Manufacturer
Seal & Signature of the Bidder
8 - 29
Vendor Response (May
propose equal or better)
8.16 Guaranteed Technical Particulars for Server Switch
(To be filled in manufacturer letterhead pad, otherwise bid will be rejected)
SL No.
Name of Item
1
2
3
4
5
6
Brand
Model
Part/Product No.
Country of origin
Country of Assemble
General Features and
Performance
7
Layer-2 Features
8
Layer-3 Features
Technical Specification and Standards
CISCO
WS-C3750x 24T-S or Higher
Should be mentioned
Should be mentioned.
Should be mentioned.
The switch should have 24 x 10/100/1000 Gigabit Ethernet
ports and capable to support 10 GB in future.
The Switch should be Stackable and should have Stacking
throughput at least 64 Gbps.
Should have Redundant Power supply from day 1.
Switching Fabric: 160 Gbps
Forwarding Rate: 65.5 Mpps
Memory: Minimum 256 MB
System Flash: Minimum 64 MB
Jumbo Frame: 9000 Byte
Up to 1005 VLANs support.
Should support 4000 VLAN IDs
Support for up to 12,000 MAC addresses, up to 11,000
unicast routes & 1000 IGMP groups and multicast routes.
IEEE 802.1Q VLAN encapsulation. Up to 1000 VLANs per
switch or stack and upto 4000 VLAN IDs
Support for Automatic Negotiation of Trunking Protocol, to
help minimize the configuration & errors.
Centralized VLAN Management. VLANs created on the
Core Switches should be propagated to all the other
switches automatically, thus reducing the overhead of
creating / modifying / deleting VLANs in all the switches
inturn eliminationg the configuration errors &
troubleshooting.
Spanning-tree PortFast and PortFast guard for fast
convergence.
Support for Uplink Fast and BackboneFast technologies to
help ensure quick failover recovery, enhancing overall
network stability and reliability.
802.1d, 802.1s, 802.1w, 802.3ad, 802.3af Power over
Ethernet (PoE)
Spanning-tree root guard to prevent other edge swicthes
becoming the root bridge.
IGMP snooping v1, v2 and v3
Port Aggregation Protocol (PAgP), Link Aggregation
Protocol (LACP)
Support for Detection of Unidirectional Links and to disable
them to avoid problems such as spanning-tree loops.
Support for Switch port autorecovery (errdisable) to
automatically reenable a link that is disabled because of a
network error.
Basic IP unicast routing protocols (static, RIPv1, and
RIPv2) from day one.
Support for IPv6 unicast routing capability (static, RIP, and
OSPF protocols) to forward IPv6 traffic through configured
interfaces.
Support for Advanced IP unicast routing protocols (OSPF,
Interior Gateway Routing Protocol [IGRP], and Border
8 - 30
Vendor Response
(May propose
equal or better)
SL No.
Name of Item
9
QoS Features
10
Network security
features
11
Management
Technical Specification and Standards
Gateway Protocol Version 4 [BGPv4]) for load balancing
and constructing scalable LANs. Policy-Based Routing
(PBR) in future.
Support for Protocol Independent Multicast (PIM) for IP
Multicast routing, including PIM sparse mode (PIM-SM),
PIM dense mode (PIM-DM), and PIM sparse-dense mode.
Support for Multicast VLAN registration (MVR) to
continuously send multicast streams in a multicast VLAN
while isolating the streams from subscriber VLANs for
bandwidth and security reasons.
Cross-stack QoS allows QoS to be configured across the
entire stack.
Standard 802.1p CoS and DSCP
Control- and Data-plane QoS ACLs
Eight egress queues per port to enable differentiated
management of up to four traffic types across the stack.
Weighted tail drop (WTD) to provide congestion avoidance
Strict priority queuing mechanisms
Up to 64 aggregate or individual policers for per Fast
Ethernet or Gigabit Ethernet port.
Granular Rate Limiting function to guarantee bandwidth in
increments as low as 8 kbps.
IEEE 802.1x to allow dynamic, port-based security,
providing user authentication.
Support for upto One thousand access control entries
(ACEs).
Spanning-Tree Root Guard (STRG) to prevent edge
devices not in the network administrator's control from
becoming Spanning Tree Protocol root nodes.
BPDU Guard feature, to shut down Spanning Tree Protocol
PortFast-enabled interfaces when BPDUs are received to
avoid accidental topology loops.
Port security to secure the access to an access or trunk
port based on MAC address. After a specific timeframe, the
aging feature should remove the MAC address from the
switch to allow another device to connect to the same port.
DHCP snooping to allow administrators to ensure
consistent mapping of IP to MAC addresses. This can be
used to prevent attacks that attempt to poison the DHCP
binding database, and to rate limit the amount of DHCP
traffic that enters a switch port.
TACACS+ and RADIUS authentication to enable
centralized control of the switch and restrict unauthorized
users from altering the configuration.
Support for SSHv2, Kerberos, and SNMPv3 to provide
network security by encrypting administrator traffic during
Telnet and SNMP sessions.
CLI support to provide a common user interface and
command set with all routers and switches of the same
vendor.
For enhanced traffic management, monitoring, and
analysis, the Embedded Remote Monitoring (RMON)
software agent should support four RMON groups (history,
statistics, alarms, and events). All nine RMON groups
should be supported through a SPAN port, which permits
traffic monitoring of a single port, a group of ports, or the
entire stack from a single network analyzer or RMON
8 - 31
Vendor Response
(May propose
equal or better)
SL No.
12
Name of Item
Warranty
Technical Specification and Standards
Vendor Response
(May propose
equal or better)
probe.
Layer 2 traceroute ot ease troubleshooting by identifying
the physical path that a packet takes from source to
destination.
Domain Name System (DNS) to provide IP address
resolution with user-defined device names.
Trivial File Transfer Protocol (TFTP) to reduce the cost of
administering software upgrades by downloading from a
centralized location.
Network Timing Protocol (NTP) to provide an accurate and
consistent timestamp to all intranet switches.
RMON I and II standards
SNMPv1, SNMPv2c, and SNMPv3.
Three years Warranty
Seal & Signature of the Manufacturer
Seal & Signature of the Bidder
8 - 32
8.17 Guaranteed Technical Particulars for Router
(To be filled in manufacturer letterhead pad, otherwise bid will be rejected)
SL No.
Name of Item
Technical Specification and Standards
1
Brand
CISCO
2
Model
2901-sec/k9 or Higher
3
Part/Product No.
Should be mentioned
4
Country of origin
Should be mentioned.
5
Country of Assemble
Should be mentioned.
6
General Features and
The Router should support Data, Voice, video
Performance
The Router should have total number of onboard
ports(10/100/1000) RJ-45: 02
Should have four 10/100/1000 switch port from day
1.
EHWIC Slots: 04
ISM slots: 01
Number of Double-Wide EHWIC slots: 02
Onboard DSP (PVDM) Slots:02
Embedded Hardware-Based Cryptography and
Acceleration (IPSec + SSL).
Performance should be minimum 330 kpps (64-byte
packets) and minimum 3114 Mbps (1500-byte
packets)
Number of concurrent sessions (1000s) 63
WAN Circuit Speed (Mbps): 25
Should have on board VPN acceleration mechanism
and VPN features from Day 1
IP private-branch-exchange (PBX) and key-system
features should support for future
Number of USB console port:01
Number of Serial console ports: 01
Number of auxiliary ports: 01
External USB 2.0 Flash Memory slots:02
Compact Flash: 256 MB(Minimum) support up to 8
GB
DRAM: 512 MB (Minimum) support up to 2 GB
7
Protocols:
IPv4, IPv6, Static Routes, Open Shortest Path First
(OSPF), Enhanced IGRP (EIGRP), Border Gateway
Protocol (BGP), BGP Router Reflector, Intermediate
8 - 33
Vendor Response (May
propose equal or better)
SL No.
Name of Item
Technical Specification and Standards
System-to-Intermediate System (IS-IS), Multicast
Internet Group Management Protocol (IGMPv3)
Protocol Independent Multicast sparse mode (PIM
SM), PIM Source Specific Multicast (SSM), Distance
Vector Multicast Routing Protocol (DVMRP), IPSec,
Generic Routing Encapsulation (GRE), BiDirectional Forwarding Detection (BVD), IPv4-toIPv6 Multicast, MPLS, L2TPv3, 802.1ag, 802.3ah,
L2 and L3 VPN
8
Encapsulation:
Ethernet, 802.1q VLAN, Point-to-Point Protocol
(PPP), Multilink Point-to-Point Protocol (MLPPP),
Frame Relay, Multilink Frame Relay (MLFR) (FR.15
and FR.16), High-Level Data Link Control (HDLC),
Serial (RS-232, RS-449, X.21, V.35, and EIA-530),
Point-to-Point Protocol over Ethernet (PPPoE), and
ATM
9
Traffic management:
QoS, Class-Based Weighted Fair Queuing
(CBWFQ), Weighted Random Early Detection
(WRED), Hierarchical QoS, Policy-Based Routing
(PBR), Performance Routing, and NBAR.
10
Power Specifications
AC input voltage: 100-240 VAC
AC input frequency: 47-63 Hz
Support Redundant Power supply.
Maximum Power capacity with AC power supply:
540 Watts
11
Environmental
Temperature: 5906 ft (1800m) maximum altitude :
specifications
32 to 104ºF(0 to 40ºC)
Operating conditions
Temperature: 9843 ft (3000m) maximum altitude: 32
to 104ºF
(0 to 40ºC)
Temperature: 13123 ft (4000m) maximum altitude:
32 to 86ºF
(0 to 30ºC)
12
Regulatory and
Safety:
Compliance:
UL 60950-1
CAN/CSA C22.2 No. 60950-1
EN 60950-1
AS/NZS 60950-1
8 - 34
Vendor Response (May
propose equal or better)
SL No.
Name of Item
Technical Specification and Standards
Vendor Response (May
propose equal or better)
IEC 60950-1
EMC:
47 CFR, Part 15
ICES-003 Class A
EN55022 Class A
CISPR22 Class A
AS/NZS 3548 Class A
VCCI V-3
CNS 13438
EN 300-386
EN 61000 (Immunity)
EN 55024, CISPR 24
EN50082-1
13
Warranty
Three years Warranty
Seal & Signature of the Manufacturer
Seal & Signature of the Bidder
8 - 35
8.18 Guaranteed Technical Particulars for Firewall
(To be filled in manufacturer letterhead pad, otherwise bid will be rejected)
Vendor Response
SL No.
Name of Item
Technical Specification and Standards
(May propose equal or
better)
1
Brand
CISCO
2
Model
ASA 5510/k9 or Higher
3
Part/Product No.
Should be mentioned
4
Country of origin
Should be mentioned.
5
Country of Assemble
Should be mentioned.
6
Form Factor
Desktop
7
General Features and
Firewall throughput: 150 Mbps
Performance
Maximum firewall connection: 10000
Maximum firewall connection/second: 4000
3DES/AES VPN throughput: 100 Mbps
VLANS: 3 (trunking disabled)/ 20 (trunking enabled)
IPsec VPN Peers: 25
Integrated interface: 8 Fast Ethernet with 2 PoE ports
Memory: 512 MB
Flash: 128 MB
The Firewall should support Layer 2 (Transparent) mode.
Firewall should support static NAT, Policy based NAT and
PAT.
Firewall should be capable of routing on VPN.
Firewall should support client based IPSec VPN Tunnels.
Support for Remote Authentication Dial-In User Service
(RADIUS) and AAA and Terminal Access Controller
Access Control System Plus (TACACS+)
8
Temperature
-13 to 158ºF (-25 to 70ºC)
9
Power (AC Range Line
100 to 240 VAC.
Voltage)
10
Warranty
Three years Warranty
Seal & Signature of the Manufacturer
Seal & Signature of the Bidder
8 - 36
8.19 Guaranteed Technical Particulars for Server Switch
(To be filled in manufacturer letterhead pad, otherwise bid will be rejected)
Vendor Response
SL No.
Name of Item
Technical Specification and Standards
(May propose equal
or better)
1
Brand
CISCO
2
Model
WS-C2960 24TC-L or Higher
3
Part/Product No.
Should be mentioned
4
Country of origin
Should be mentioned.
5
Country of Assemble
Should be mentioned.
6
General Features and
The switch should have minimum 24 Ethernet 10/100 ports
Performance
& 2 dual-purpose uplink (dual-purpose uplink port has 1
10/100/1000 Ethernet port,1 SFP-based Gigabit Ethernet
port, 1 port active)
Support for Redundant Power supply
16 Gbps Forwarding bandwidth
32 Gbps Switching bandwidth
Forwarding rate: 6.5 Mpps
Configurable up to 8000 MAC addresses
7
Layer-2 Features
IEEE 802.1Q VLAN encapsulation. Upto 255 VLANs should
be supported. Support for 4000 VLAN IDs.
Support for Automatic Negotiation of Trunking Protocol, to
help minimize the configuration & errors.
Centralized VLAN Management. VLANs created on the Core
Switches should be propagated automatically.
Spanning-tree PortFast and PortFast guard for fast
convergence
UplinkFast & BackboneFast technologies to help ensure
quick failover recovery, enhancing overall network stability
and reliability.
802.1d, 802.1s, 802.1w, 802.3ad
Spanning-tree root guard to prevent other edge swicthes
becoming the root bridge.
IGMP snooping v3, Support for upto 256 IGMP Groups.
IGMP filtering.
Port Aggregation Protocol (PAgP), Link Aggregation Protocol
(LACP)
Support for Detection of Unidirectional Links and to disable
them to avoid problems such as spanning-tree loops.
8 - 37
Vendor Response
SL No.
Name of Item
Technical Specification and Standards
(May propose equal
or better)
The Switch should be able to discover the neighboring
device of the same vendor giving the details about the
platform, IP Address, Link connected through etc, thus
helping in troubleshooting connectivity problems.
Per-port broadcast, multicast, and storm control to prevent
faulty end stations from degrading overall systems
performance.
Local Proxy Address Resolution Protocol (ARP) to work in
conjunction with Private VLAN Edge to minimize broadcasts
and maximize available bandwidth.
Multicast VLAN registration (MVR) to continuously send
multicast streams in a multicast VLAN while isolating the
streams from subscriber VLANs for bandwidth and security
reasons.
8
Network security
IEEE 802.1x to allow dynamic, port-based security, providing
features
user authentication.
Port-based ACLs for Layer 2 interfaces to allow application
of security policies on individual switch ports.
SSHv2 and SNMPv3 to provide network security by
encrypting administrator traffic during Telnet and SNMP
sessions.
Bidirectional data support on the Switched Port Analyzer
(SPAN) port to allow the intrusion detection system (IDS) to
take action when an intruder is detected.
TACACS+ and RADIUS authentication enable centralized
control of the switch and restrict unauthorized users from
altering the configuration.
MAC address notification to allow administrators to be
notified of users added to or removed from the network.
DHCP snooping to allow administrators to ensure consistent
mapping of IP to MAC addresses. This can be used to
prevent attacks that attempt to poison the DHCP binding
database, and to rate-limit the amount of DHCP traffic that
enters a switch port.
Up to 512 ACL entries should be supported.
BPDU Guard to shut down Spanning Tree Protocol PortFastenabled interfaces when BPDU’s are received to avoid
8 - 38
Vendor Response
SL No.
Name of Item
Technical Specification and Standards
(May propose equal
or better)
accidental topology loops.
9
Quality of Service
Standard 802.1p CoS and DSCP
(QoS) & Control
Control- and Data-plane QoS ACLs
Four egress queues per port to enable differentiated
management of up to four traffic types across the stack.
Weighted tail drop (WTD) to provide congestion avoidance
Strict priority queuing mechanisms
Rate Limitting function should guarantee bandwidth in
increments as small as 1 Mbps.
Up to 64 aggregate or individual polices should be available
per Fast Ethernet or Gigabit Ethernet port.
10
Management
CLI support to provide a common user interface and
command set with all routers and switches of the same
vendor.
For enhanced traffic management, monitoring, and analysis,
the Embedded Remote Monitoring (RMON) software agent
should support four RMON groups (history, statistics,
alarms, and events). All nine RMON groups should be
supported through a SPAN port, which permits traffic
monitoring of a single port, a group of ports, or the entire
stack from a single network analyzer or RMON probe.
Layer 2 traceroute ot ease troubleshooting by identifying the
physical path that a packet takes from source to destination.
Domain Name System (DNS) to provide IP address
resolution with user-defined device names.
Trivial File Transfer Protocol (TFTP) to reduce the cost of
administering software upgrades by downloading from a
centralized location.
Network Timing Protocol (NTP) to provide an accurate and
consistent timestamp to all intranet switches.
RMON I and II standards
SNMPv1, SNMPv2c, and SNMPv3.
11
Warranty
Three years Warranty
Seal & Signature of the Manufacturer
Seal & Signature of the Bidder
8 - 39
8.20 Guaranteed Technical Particulars Of Database
(To be filled up and signed by the Manufacturer & Tenderer (a or b as per offer), otherwise the offer will not be
acceptable)
a) Oracle Database:
Sl
No.
1
Name of Item
Brand
2
Version
3
Description
4
License
5
Media
6
Brochure
7
Installation
8
Support service
Manufacturer
Particulars Guaranteed
Required specifications
Oracle
ORACLE 11g Database Enterprise Edition for LINUX
(64 bit) or Latest
Oracle 11g Enterprise Edition
(a) Partitioning
(b) Real Application Clusters
(c) Diagnostics Pack
(d) Tuning Pack
(i) Min. 5 users for 2 node DC cluster
(ii) Min. 5 Users for DR
CD/DVD Media Pack
All brochure, instruction manual and
corresponding CDs will be supplied with the product
The RDMS should be installed, Configured &
commissioned by the supplier
8 Years full Support Service
b) MS SQL Database:
Sl
Name of Item
No.
1
Brand
2
Version
3
4
5
6
License
Brochure
Installation
Support service
Manufacturer
Particulars Guaranteed
Required specifications
MS SQL
MS SQL Server 2012 Enterprise Edition or Latest
For Windows 2012 Server with License and Media
(i) Min. 5 users for 2 node DC cluster
(ii) Min. 5 Users for DR
All brochure, instruction manual and
corresponding CDs will be supplied with the product
The RDMS should be installed, Configured &
commissioned by the supplier.
8 Years full Support service
Seal & Signature of the Manufacturer
Seal & Signature of the Bidder
8 - 40
8.21 Particular Specifications Prepayment Electric Energy Meter
8.21.1 Technical Data Schedule For 230 Volt 10(60) A Split-type Prepayment Electric Energy Meter
(To be filled up and signed by the Manufacturer & Bidder, otherwise the offer will not be acceptable
Sl. No.
Description
Unit
1.
Reference Standard
-
2.
Country of Origin
3.
Manufacturer’s Name & address
4.
Place of Manufacturer
5.
Year of Manufacture & Testing
6.
Model of Meter.
7.
Generation of the offered Meter
8.
Type
9.
Installation
10.
11.
12.
13.
14.
15.
Connection
Rated voltage
Maximum voltage
Base Current
Maximum Current
Frequency
Volt
Volt
Amp
Amp
50HZ
16.
17.
Number of Terminal
Diameter of Terminal; Bore
No.
mm
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
No. of Element
Voltage circuit loss at rated voltage
Current circuit loss at rated current
Variation of Power factor
Variation of voltage
Biasing Voltage (min)
Performance Curve
Impulse withstand voltage
Starting current (minimum)
KWh register type
Meter constant
No.
VA & W
VA
29.
Accuracy class
30.
Type of Battery
31.
No. of Digits for Credit Storage
32.
Token Technology
BPDB'S Requirement
IEC Standard (as per section
7-B2(i)cl. 6)
To be mentioned by the
Tenderer/Supplier.
To be mentioned by the
Tenderer/Supplier.
To be mentioned by the
Tenderer/Supplier.
To be mentioned by the
Tenderer/Supplier.
To be mentioned by the
Tenderer/Supplier.
To be mentioned by the
Tenderer/Supplier.
To be mentioned by the
Tenderer/Supplier.
Indoor type
-
-
Volt
KV
mA
Impulse/k
Whr
Class
5 +1
1- phase, 2-wire
230
280
<=10
>=60
To be mentioned by the
Tenderer/Supplier.
4
6mm to accommodate 10 mm2
cable
1.5
To be mentioned
2.5
0.5 lag to 0.8 lead
-25% to +30%
150
To be submitted
6
0.4% of base current
LCD Display
To be mentioned
1.0
Lithium Battery,
if necessary
5+1
Non-contact
membrane keypad
8 - 41
Vendor Response (May
propose equal or better)
Sl. No.
Description
Unit
BPDB'S Requirement
33.
KWhr dispensing register
34.
Front Page Indications (UIU)
- Credit Status,
- accept/Reject,
- Low credit warning,
- Consumption Rate,
- Tamper Indication
35.
Disconnection Facility
- On credit expiry,
- Decommissioning state
- Exceeded Power threshold
- And when Tampered
- Neutral Missing
To be Mentioned
Solid state LCD Display
36.
Provision for emergency Friendly
Credit
37
38
Provision for Fixed charge/
Minimum charge
Time interval of re-calibration (minimum)
Year
10
39
Service life (minimum)
Year
10
40
Weight of meter
41
To be Mentioned
i)
MCU
Kg
To be mentioned
ii)
UIU
Kg
To be mentioned
Overall dimensions (height, width,
depth)
i)
ii)
MCU
UIU
42
Warranty
43
44
45
List of Recommended Spares
Any other facility if any
Communication between MCU &
UIU
Vendor Response (May
propose equal or better)
To be mentioned
mm
mm
Years
To be mentioned
To be mentioned
3 Years
To be mentioned
Seal & Signature of the Manufacturer
Seal & Signature of the Bidder
8 - 42
8.21.2 Technical Data Schedule For 230 Volt 10(60) A Non-Split type Prepayment Solid State Energy Meter
(To be filled up and signed by manufacturer and Bidder, otherwise the offer will not be acceptable)
Sl. No.
Description
Unit
-
3.
4.
5.
6.
7.
8.
Reference Standard
Country of Origin
Manufacturer’s Name & address
Place of Manufacturer
Year of Manufacture & Testing
Model of Meter.
Generation of the offered Meter
Type
9.
Installation
10.
11.
12.
13.
14.
15.
16.
17.
Connection
Rated voltage
Maximum voltage
Basic Current
Maximum Current
Frequency
Number of Terminal
Diameter of Terminal; Bore
Volt
Volt
Amp
Amp
50HZ
No.
mm
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
No. of Element
Voltage circuit loss at rated voltage
Current circuit loss at rated current
Variation of Power factor
Variation of voltage
Biasing Voltage (min)
Performance Curve
Impulse withstand voltage
Starting current (minimum)
KWh register type
Meter constant
No.
VA & W
VA
29.
Accuracy class
30.
Type of Battery
31.
No. of Digits for Credit Storage
1.
2.
32.
BPDB'S Requirement
-
IEC Standard (as per cl. 4.2)
To be mentioned
To be mentioned
To be mentioned
To be mentioned
To be mentioned
-
To be mentioned
Indoor type
Volt
KV
mA
Impulse/
kWhr
Class
5 +1
1- phase, 2-wire
230
280
<=10
>=60
To be mentioned
4
6mm to accommodate 10 mm2
cable
1.5
To be mentioned
2.5
0.5 lag to 0.8 lead
-20% to +15%
150
To be submitted
6
0.4% of basic current
LCD Display
To be mentioned
1.0
Lithium Battery,
if necessary
5+1
33.
Token Technology
For Smart Card: Smart Card Slot
For Numeric Token: Non-contact
membrane keypad
Tariff Structure
To be mentioned
BPDB's Tariff structure
34.
KWhr dispensing register
Solid state LCD Display
8 - 43
Vendor Response (May
propose equal or better)
Sl. No.
Description
35.
Front Page Indications
36.
Disconnection Facility
37.
Provision for emergency Friendly
Credit
Provision for Fixed charge/ Minimum
charge
Time interval of re-calibration (minimum)
Service life (minimum)
Weight of meter
Overall dimensions (height, width,
depth)
Warranty
List of Recommended Spares
Any other facility if any
38.
39.
40.
41.
42.
43.
44.
45.
Unit
BPDB'S Requirement
- Credit Status,
- accept/Reject,
- Low credit warning,
- Consumption Rate,
- Tamper Indication
- On credit expiry,
- Decommissioning state
- Exceeded Power threshold
- And when Tampered
To be Mentioned
To be Mentioned
Year
Year
Kg
mm
10
10
To be mentioned
To be mentioned
Years
3 Years
Seal & Signature of the Manufacturer
Seal & Signature of the Bidder
8 - 44
Vendor Response
(May propose
equal or better)
8.21.3 Technical Data Schedule For 400 Volt 10(100) A Non-Split type Prepayment Solid State Energy Meter
(To be filled up and signed by manufacturer and Bidder, otherwise the offer will not be acceptable)
Sl. No.
Description
1
2
3
4
5
6
7
8
Reference Standard
Country of Origin
Manufacturer’s Name & address
Place of Manufacturer
Year of Manufacture & Testing
Model of Meter.
Generation of the offered Meter
Type
9
Installation
10
11
12
3
14
15
16
17
Connection
Rated voltage
Maximum voltage
Basic Current
Maximum Current
Frequency
Number of Terminal
Diameter of Terminal; Bore
18
19
20
21
22
23
24
25
26
27
No. of Element
Voltage circuit loss at rated voltage
Current circuit loss at rated current
Variation of Power factor
Variation of voltage
Biasing Voltage (min)
Performance Curve
Impulse withstand voltage
Starting current (minimum)
KWh register type
Meter constant
28
29
30
Accuracy class
33
Type of Battery
No. of Digits for Credit Storage
Token Technology
For Smart Card: Smart Card Slot
For Numeric Token: Non-contact
membrane keypad
Tariff Structure
34
35
KWhr dispensing register
Front Page Indications
36
Disconnection Facility
37
Provision
for
emergency
Friendly Credit
Provision for Fixed charge/
31
32
38
Unit
BPDB'S Requirement
-
-
IEC standard (as per cl. 4.2)
To be mentioned
To be mentioned
To be mentioned
To be mentioned
To be mentioned
-
To be mentioned
Indoor type
Volt
Volt
Amp
Amp
50HZ
No.
mm
KV
mA
Impulse/kWh
3- phase, 4-wire
400
480
<=10
>=100
50HZ
11
8.5 to accommodate
25q m cable
3
To be mentioned
2.5
0.5 lag to 0.8 lead
-20% to +15%
150V Phase to neutral
To be submitted
6
0.4% of basic current
LCD Display
To be mentioned
Class
1.0
No.
VA & W
VA
Volt
5+2
To be mentioned
5+2
To be mentioned
BPDB's Tariff structure
Solid state LCD Display
- Credit Status,
- accept/Reject,
- Low credit warning,
- Consumption Rate,
- Tamper Indication
- On credit expiry,
- Decommissioning state
- Exceeded Power threshold
- And when Tampered
To be Mentioned
To be Mentioned
8 - 45
Vendor Response (May
propose equal or better)
Sl. No.
39
40
41
42
43
44
45
Description
Minimum charge
Time
interval
of
re-calibration
(minimum)
Service life (minimum)
Weight of meter
Overall dimensions (height,
width, depth)
Warranty
List of Recommended Spares
Any other facility if any
Unit
Year
BPDB'S Requirement
10
Year
Kg
mm
10
To be mentioned
To be mentioned
Year
3 Years
Seal & Signature of the Manufacturer
Vendor Response (May
propose equal or better)
Seal & Signature of the Bidder
8 - 46
8.23 Guaranteed Technical Particulars for Accuracy Verifiers
(To be filled in manufacturer letterhead pad, otherwise bid will be rejected)
Item
No
Name of Item
1
01.
02.
03.
04.
05.
06.
07.
08.
09.
2
Manufacturer Name
BPDB'S Requirement
3
4
Manufacturer Address
To be mentioned
To be mentioned
Model no.
To be mentioned
Country of Origin
To be mentioned
Type
Portable
Accuracy Class
Rated Voltage
Verification time
Vendor Response (May propose
equal or better)
To be mentioned
Comply to IEC 1036
1
230V
Less than 90 seconds
Seal & Signature of the Manufacturer
Seal & Signature of the Bidder
8 - 47
8.23 Guaranteed Technical Particulars for Hank Held Units
(To be filled in manufacturer letterhead pad, otherwise bid will be rejected)
Item
No
Name of Item
1
01.
02.
03.
04.
05.
06.
07.
08.
BPDB'S Requirement
2
Manufacturer Name
3
Manufacturer Address
To be mentioned
To be mentioned
Model no.
To be mentioned
Country of Origin
To be mentioned
Type
Transaction capacity
Rechargeable Battery
Communications
Interface
Vendor Response (May propose equal
or better)
4
To be mentioned
500
8 hours
IEC 1107
Seal & Signature of the Manufacturer
Seal & Signature of the Bidder
8 - 48
8.24 Guaranteed Technical Particulars for Service Connection Materials
(To be field up by the manufacturer, otherwise the bid will be rejected)
Service Bale
Sl.
Description
Purchaser’s
No.
Requirement
Compatible for taking off Service drops from LT Lines.
1.
Shall be mentioned
2.
Name & address of the
Manufacturer
Manufacturer’s Code
3.
Applicable Standard
4.
Installation
5.
Type
BS, IEC, VDE or equivalent
international standard
Outdoor and shall be installed them on
low-tension lines in order to taking off
service drops from them.
PVC Insulated
6.
Thickness of Insulation
1 (one) mm
7.
Size of Bail
6 SWG Copper
8.
Shape
U-shaped
9.
Length of Copper Wire
458 mm
10.
Weight in Kg
Shall be mentioned
Vendor Response (May
propose equal or better)
Shall be mentioned
Seal & Signature of the Manufacturer
Seal & Signature of the Bidder
8 - 49
8.24.1 Guaranteed Technical Particulars for Service Connection Materials
(To be field up by the manufacturer, otherwise the bid will be rejected)
Compression type Connector
Sl.
Description
No.
Vendor Response (May
propose equal or better)
Purchaser’s
Requirement
Compatible for ACSR MERLIN to ACSR MERLIN Conductor
1.
Name & Address of the
Shall be mentioned
Manufacturer
2.
Manufacturer’s Code No.
Shall be mentioned
3.
4.
Applicable Standard
Installation
5.
6.
7.
Type
Material
Continuous current rating
8.
9.
10.
Length
Weight of 100 nos. in Kg
Dimensional Drawing
BS, IEC, BDS or equivalent standard
Outdoor and shall be installed for the
above-mentioned conductor.
H-Type
Aluminum
Shall be mentioned and capable of
carrying the continuous current of the
specified conductor in Amps.
112 mm
Shall be mentioned
Shall be enclosed
Seal & Signature of the Manufacturer
Seal & Signature of the Bidder
Technical Particulars & Guaranteed Data Schedule of Shackle Insulator
(To be filled up by the Manufacturer, otherwise the bid will not be considered for Evaluation.)
Item
No.
1
01.
02.
03.
04.
05.
06.
07.
08.
09.
10.
11.
12.
13.
Description
2
Name of Manufacturer & Address
Manufacturer’s Code No.
Type
Line Voltage
Material
Leakage Distance, min
Flash over Voltage
Power Frequency, Dry
Power Frequency, Wet
Power Frequency Puncture Voltage
Transverse Strength, min
Height, max
Dia, max
Groove Dia.
Insulator Hole Dia., min
Specified Data
Vendor Response (May
propose equal or better)
3
To be mentioned
To be mentioned
LV Shackle
230/400 V
Glazed Porcelain
64 mm
25 kV
12 kV
70 kV
1140 Kg
76 mm
89 mm
19 mm
17.5 mm
Seal & Signature of the Manufacturer
Seal & Signature of the Bidder
8 - 50
4
(Guaranteed Technical Particulars)
(To be filled up by the Manufacturer, otherwise the bid will not be considered for Evaluation.)
Insulated Piercing Connector
Item
No.
Description
Purchaser's Requirement
Vendor Response
(May propose equal
or better)
Compatible for House Service Tap-off from 35-70 mm2 Run Conductor
01.
Name of Manufacturer & Address
Shall be mentioned
02.
Manufacturer’s Code No.
Shall be mentioned
03.
Applicable Standard
04.
Installation
05.
Material
06.
Dimension
BS, IEC, BD or equivalent
international standard
Outdoor and Shall be installed
for Al and/or Cu Conductor
Plated hardened copper alloy
with PVC Insulation
Shall be mentioned
07.
Current carrying Capacity
Shall be mentioned
08.
Weight in Gram
Shall be mentioned
09.
Dimensional Drawing
Shall be Enclosed
Seal & Signature of the Manufacturer
Seal & Signature of the Bidder