HP ProLiant DL360 Generation 5

QuickSpecs
HP ProLiant DL360 Generation 5
Overview
1. Low-profile x8 PCI-Express slot
2. Eight PC2-5300 FB-DIMMs (DDR2 667) slots
6. Up to six SAS/SATA hot plug drive bays
7. Removable fans for easy serviceability
3. Up to two Intel Quad-Core or Dual-Core Xeon™
processors
4. Slide-out System Insight Display
5. Slimline removable media bay
8. Choice of Smart Array P400i Controller or Smart Array
E200i Controller
9. Redundant Hot Plug Power Supplies (upgradeable
option)
10. Full length/height x8 PCI-Express Slot (optional PCI-X)
What's New
New Quad-Core Intel Xeon 5300 sequence processor models are now available with 1333GHz Front Side Bus speed,
with 8M (2x4MB) L2 Cache (X5355 120W, E5345 80W, E5335 80W)
At A Glance
Combining concentrated 1U compute power, integrated Lights-Out management, and essential fault tolerance, the DL360 is
optimized for space constrained installations. Dual-core Xeon processors, DDR2 Fully Buffered DIMMs, Serial Attached
SCSI (SAS) and PCI Express technology provide a high performance system ideal for the full range of scale out
applications. What's more, the HP ProLiant DL360 G5 steps up the fault tolerant in an ultra dense platform with redundant
power, redundant fans, mirrored memory or online spare memory, embedded RAID capability, and full-featured remote
Lights-Out management.
Processors:
Up to (2) Quad-Core or Dual-Core Intel® Xeon® processor 5000 sequence
Up to (2) Quad-Core Intel Xeon processor 5300 sequence
Intel 5000P chipset supporting up to a 1333MHz front-side bus
Memory:
Up to 32 GB of memory, supported by (8) slots of PC2-5300 Fully Buffered DIMMs (DDR2-667); 4:1 interleaving;
memory mirroring; online spare
Storage Controller:
Performance Models: HP Smart Array P400i/256MB BBWC Controller (RAID 0/1/1+0/5/6) (512MB BBWC
optional)
Base Models: HP Smart Array P400i/256MB Controller (RAID 0/1/1+0/5) (512MB BBWC optional)
Entry Models: HP Smart Array E200i/64MB Controller (RAID 0/1/1+0) (128MB BBWC optional)
Internal Drive Support:
Up to (6) small form factor (SFF) hot-plug drive bays
Slimline media bay supporting DVD, CD or Floppy drive
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
Page 1
QuickSpecs
HP ProLiant DL360 Generation 5
Overview
Network Controller:
Embedded NC373i Multifunction Gigabit Server Adapters with TCP/IP Offload Engine, including support for
Accelerated iSCSI and RDMA through optional ProLiant Essentials Licensing Kits
Expansion Slots:
Two PCI-Express expansion slots: (1) full-length, full-height slot; (1) low-profile slot
Front or rear accessible video port
USB 2.0 Ports:
4 Total: (1) front, (1) internal and (2) rear accessible ports
Redundancy:
Multiple layers of fault tolerance through critical component redundancy (power supply and fan redundancy),
mirrored memory, embedded RAID capability, and full-featured remote Lights-Out management
Management:
New Integrated Lights-Out 2 featuring Integrated Remote Console with KVM over IP performance over shared
network access
HP Power Meter and Power Regulator for ProLiant, delivering integrated power monitoring and server level,
policy based power management with industry leading energy efficiency and savings on system power and
cooling costs
Convenient slide-out Systems Insight Display for quick and easy front view server diagnostics
ProLiant Essential Foundation Pack standard, including HP Systems Insight Manager, SmartStart, SmartStart
Scripting Toolkit, Subscriber's Choice and ROM Based Setup Utility (RBSU)
Automatic Server Recovery (ASR), ROM Based Setup Utility (RBSU), HP System Insight Manager, Status LEDs
including system health, UID, and SmartStart
Form Factor:
1U Rack form factor (1.75"), less than 28 inches (70.5 cm) deep
Deployment/Serviceability:
Sliding rails for in rack servicing ship standard; optional ambidextrous cable management arm
Warranty:
Protected by HP Services and a worldwide network of resellers and service providers. Three-year next business
day, on-site limited global warranty. Certain restrictions and exclusions apply. Pre-failure notification on
processors, memory, and SAS hard drives. SATA hard drives have a one-year warranty.
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
Page 2
QuickSpecs
HP ProLiant DL360 Generation 5
Standard Features
NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information –
Factory Integrated Models" section.
Processor
Dual-Core Intel Xeon Processor X5355 (2.66 GHz, 120 Watts, 1333 Front Side Bus (FSB)
One of the following
Quad-Core Intel Xeon Processor E5345 (2.33 GHz, 80 Watts, 1333 FSB)
depending on Model
Quad-Core Intel Xeon Processor E5320 (1.86 GHz 80 Watts, 1066 FSB)
Quad-Core Intel Xeon Processor E5310 (1.60 GHz 80 Watts, 1066 FSB)
Dual-Core Intel Xeon Processor 5160 (3.0 GHz, 80 Watts, 1333 FSB)
Dual-Core Intel Xeon Processor 5150 (2.67 GHz, 65 Watts, 1333 FSB)
Dual-Core Intel Xeon Processor 5148 (2.33 GHz, 40 Watts, 1333 FSB, Low Voltage)
Dual-Core Intel Xeon Processor 5140 (2.33 GHz, 65 Watts, 1333 FSB)
Dual-Core Intel Xeon Processor 5130 (2.0 GHz, 65 Watts, 1333 FSB)
Dual-Core Intel Xeon Processor 5120 (1.86 GHz, 65 Watts, 1066 FSB)
Dual-Core Intel Xeon Processor 5110 (1.6 GHz, 65 Watts, 1066 FSB)
Dual-Core Intel Xeon Processor 5080 (3.73GHz, 130 Watts, 1066 FSB)
Dual-Core Intel Xeon Processor 5060 (3.2GHz, 130 Watts, 1066 FSB)
NOTE: Up to 2 processors supported. Performance configurations include two processors.
NOTE: Intel 5300 sequence processors are 64-bit, Quad-Core, and supports Intel VT technology.
Intel 5100/5000 sequence processors are 64-bit, Dual-Core, and supports Intel VT technology.
Cache Memory
One of the following
depending on Model
8MB (2 x 4MB) Level 2 cache (5300 sequence)
4MB (1 x 4MB) Level 2 cache (5100 sequence)
4MB (2 x 2MB) Level 2 cache (5000 sequence)
Upgradeability
Upgradeable to quad or dual processing
Future upgradeable to Xeon Series 5300 Quad-Core, or 5100 Dual-Core processors
Chipset
Intel 5000P chipset
NOTE: For more information regarding Intel chipsets, please see the following URL:
http://www.intel.com/products/server/chipsets/.
Memory Protection &
Functionality
Advanced ECC (multi-bit error protection), Online Spare, Mirroring
4-way interleaving
Memory
Type
PC2-5300 Fully Buffered DIMMs (DDR2-667)
Standard (Entry or Base 1 GB (2 x 512 MB)
Models)
Standard (Performance 2 GB (2 x 1 GB)
Models)
Standard (Performance 4 GB (4 x 1 GB)
Model E5345)
Maximum
32 GB (8 x 4 GB)
NOTE: Memory DIMMs in systems with the Front Side Bus (FSB) running at 1333 MHz will run at
667 MHz and in systems with a FSB running at 1066 MHz or 667 MHz the memory DIMMs will run
at 533 MHz.
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
Page 3
QuickSpecs
HP ProLiant DL360 Generation 5
Standard Features
Network Controller
Embedded NC373i Multifunction Gigabit Server Adapters with TCP/IP Offload Engine, including
support for Accelerated iSCSI and RDMA through optional ProLiant Essentials Licensing Kits
Expansion Slots
Slot Number Bus Speed
1
2
2
Bus
Number*
11
19
16
Device
Number**
0
0
1
Hot Plug
PCI Voltage
x8 PCI Express
no
N/A
x8 PCI Express
no
N/A
64-bit/133MHz
no
3.3 Volt
PCI-X (option)
*NOTE: Default bus assignment. Inserting cards with PCI bridges may alter the actual bus
assignment number.
**NOTE: Slots are enumerated differently based on OS. Microsoft OS's enumerate from lowest to
highest Device ID by bus (starting with the lowest bus).
Manageability
Integrated Lights Out 2 (iLO 2) Standard Management:
Virtual Text Remote Console
Virtual Power Button Control
Integrated Remote Console
Dedicated & full function shared network connectivity
Embedded system health
Browser, command line and scripted access
Automatic IP Configuration via DHCP/DNS/WINS
Industry Standard 128-bit Secure Sockets Layer (SSL) and Secure Shell security (SSH)
OS independent hardware health status
IML and iLO Event Logging
Support for 12 user accounts with customizable access privilege
Storage Controller
One of the following
depending on Model
Performance Models:
Base Models:
Entry Models:
Storage
Optical Drives
(Slimline Drive bay)
Drive Bays
HP Smart Array P400i/256MB BBWC Controller (RAID 0/1/1+0/5/6)
Available upgrades: 512MB memory battery-backed write cache
(BBWC) module for RAID 0/1/1+0/5/6.
HP Smart Array P400i/256MB Controller (RAID 0/1/1+0/5)
Available upgrades: 512MB memory battery for battery-backed write
cache (BBWC) module for RAID 0/1/1+0/5/6, or battery-backed write
cache for RAID 0/1/1+0/5/6.
HP Smart Array E200i/64MB Controller (RAID 0/1/1+0)
Available upgrades: 128MB memory battery for battery-backed write
cache (BBWC) module for RAID 0/1/1+0/5.
Optional DVD-ROM, DVD/CD-RW Combo (standard in performance
models), DVD-RW, or Slimline floppy drive
Up to 6 Small Form Factor bays total
NOTE: 4 bays active in most models. Smart Array P400i controller and
Mini-SAS storage cable (P/N 399546-B21) required for activation of 5th
and 6th drive bays.
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
Page 4
QuickSpecs
HP ProLiant DL360 Generation 5
Standard Features
Maximum Internal
Storage Type
Interfaces
Hot Plug Serial Attached 876GB SAS
SCSI (SAS)
Hot Plug Serial ATA
360GB SATA
(SATA)
Keyboard
Mouse
Serial
Video
USB 2.0 Ports
Network RJ-45
iLO 2 remote
management port
6 x 146GB SAS
6 x 60GB SATA
1
1
1
1
4 total: 2 rear, 1 front, 1 internal
NOTE: Please see the following URL for additional information
regarding USB support:
http://h18004.www1.hp.com/products/servers/platforms/usbsupport.html.
2
1
Graphics
Integrated ATI ES1000 1280 x 1024 x 16M color (32MB video standard)
Form Factor
Rack (1U), (1.75 in/4.45 cm); 27.75 inch depth (70.5cm)
ProLiant Essentials
Foundation Pack
Software
HP Systems Insight
Manager
HP Systems Insight Manager (HP SIM) provides a unified, secure and
extensible environment to centrally manage servers, storage and other
infrastructure devices across multiple operating system platforms.
Through a single management view, HP SIM provides core
management services that include device discovery and identification,
event views, health monitoring, inventory data collection, software
version control and reporting. HP SIM is built on industry standards and
is extensible with value-added ProLiant Essentials, Integrity Essentials
and Storage Essentials software to meet individual management needs.
For more details on HP SIM visit http://www.hp.com/go/hpsim.
HP SIM provides organizations with the following benefits:
SmartStart
Simplifies and consolidates infrastructure lifecycle management
using task and query based functionality
Provides the foundation for infrastructure automation and
virtualization
Enables IT management based on business processes not
hardware platforms
Lowers infrastructure maintenance cost and frees resources for
innovation
Maximizes resource utilization with virtualization technologies
Provides a central point of integration between infrastructure and
Enterprise management tools such as HP OpenView
SmartStart is a tool that simplifies server setup, providing a rapid way to
deploy reliable and consistent server configurations. For more
information, please visit the SmartStart Web site at
http://www.hp.com/servers/smartstart.
SmartStart version supported (minimum): SmartStart 7.60.
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
Page 5
QuickSpecs
HP ProLiant DL360 Generation 5
Standard Features
Insight Management
Agents
Insight Management Agents should be installed on all HP servers to
present system instrumentation, health and configuration information
into HP Systems Insight Manager and the HP System Management
Homepage. The HP System Management Homepage aggregates
systems data from Insight Management Agents and other HP
management tools, providing a consolidated browser-based interface
for managing individual servers,
Insight Management Agents and The HP System Management
Homepage are included on ProLiant Support Packs, and can also be
installed using the server profiles provided with the ProLiant Essentials
Rapid Deployment Pack. For additional information about the
Management Agents and the HP System Management Homepage
please visit the management Web site at
http://www.hp.com/servers/manage.
Subscriber's Choice
Subscriber's Choice Driver and Support Alerts/Notifications is a webbased email subscription service that provides automatic delivery of
software and driver change notifications for ProLiant products. Sign up
at http://www.hp.com/go/subscriberschoice and customize your profile
to receive various new alerts as they become available, on a weekly or
monthly basis.
ROMPaq, support
The latest software, drivers, and firmware fully optimized and tested for
software, and
your ProLiant server and options available in SmartStart or
configuration utilities
downloadable from Software and Drivers download pages:
http://www.hp.com/go/support
Insight Diagnostics
The most advanced configuration analysis, reporting and
troubleshooting utilities used by HP and at your fingertips, available in
SmartStart.
Optional ProLiant
Optional software offerings that selectively extend the functionality of an
Essentials Value Packs Adaptive Infrastructure to address specific business problems and
needs:
Rapid Deployment Pack (RDP) is an automated deployment and
provisioning solution for all ProLiant servers. RDP includes the
ProLiant Integration Module featuring ProLiant server preconfigured events for OS installation, and optimized software
drivers, firmware and management agents. Every RDP disc
includes 7-day, 10-node trial licenses for evaluation purposes.
RDP requires a license for each server deployed and is available
for purchase with HP servers. For more information, visit:
http://www.hp.com/servers/rdp.
Workload Management Pack – provides easier management of
complex environments, improving overall server utilization and
enabling Windows® 2000 customers for the first time to
confidently deploy multiple applications on a single multiprocessor
ProLiant Server.
Performance Management Pack – a performance management
solution that identifies and explains hardware performance
bottlenecks on ProLiant servers and attached options enabling
users to better utilize their valuable resources.
Intelligent Networking Pack – detects and analyzes network
bottlenecks or broken network linkages and steers traffic to the
optimum route based on network conditions, plus it provides an
extra layer of protection. The virus throttle feature of the solution
slows the propagation of fast spreading virus.
Vulnerability and Patch Management Pack – identifies and
remediates software security vulnerabilities due to missing
patches as well operating system configurations that can be
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
Page 6
QuickSpecs
HP ProLiant DL360 Generation 5
Standard Features
exploited by viruses, worms, and other blended threats
Virtual Machine Management Pack – provides central
management and control of virtual machines from Microsoft and
VMware. Integrated approach provides the ability to manage both
physical and virtual resources from a single management
console.
Server Migration Pack – The Server Migration Pack automates
the manual processes required for migrating servers between
physical or virtual platforms (P2V, V2P, and V2V).
Server Migration Pack – P2P Edition: Upgrading or replacing your
existing server? Effortlessly transition to new servers with
automated, accurate and affordable migration of OS, application
and data.
Accelerated iSCSI Pack - enables the embedded Multifunction
network controller to serve as both a NIC and an iSCSI HBA
providing access to SAN storage over the same connection used
for networking. Processing of the protocol stack is offloaded to the
NIC reducing CPU utilization and greatly improving the speed with
which the requests are processed and sent to the network.
Remote Directory Memory Access (RDMA) Pack for Embedded
Multifunction Gigabit Server Adapters – provides direct and faster
communication between application buffers in separate servers
for tasks that involves moving large amounts of data, such as
network backups, database read/write, and high performance
computing.
Optional Remote
Integrated Lights-Out Advanced Pack - upgrades the iLO 2
Management Packs
processor with comprehensive remote control including Virtual
KVM graphical console, virtual media, power management and
enterprise security.
Insight Power Manager (IPM) - upgrades the single-server remote
management capabilities of iLO Select/Advanced to include
centralized reporting and policy-based management of power
consumption and thermal output provided by the Insight Power
Manager. IPM unifies all of this functionality within a single user
interface - HP Systems Insight Manager.
Insight Control Environment - Includes a singe product key to
license the ProLiant Essentials Performance Management Pack,
ProLiant Essentials Vulnerability and Patch Management Pack,
and Insight Power Manager, plus separate product registration
codes to license the ProLiant Essentials Rapid Deployment Pack
and the iLO Advanced Pack.
NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials Value
Packs. Refer to http://www.hp.com/servers/proliantessentials or the various ProLiant Essentials
Value Pack product QuickSpecs for more information.
NOTE: For more information regarding ProLiant Essentials Software, please see the following
URL: http://www.hp.com/servers/proliantessential.
Industry Standard
Compliance
ACPI 2.0b Compliant
PCI 2.2 Compliant
WOL Support
Microsoft® Logo certifications
PXE Support
USB 1.1 and 2.0 Compliant
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
Page 7
QuickSpecs
HP ProLiant DL360 Generation 5
Standard Features
Remote Management Integrated Lights Out 2 (iLO2) Standard Management:
Virtual Text Remote Console
Virtual Power Button Control
Integrated Remote Console
Dedicated & full function shared network connectivity
Embedded system health
Browser, command line and scripted access
Automatic IP Configuration via DHCP/DNS/WINS
Industry Standard 128-bit Secure Sockets Layer (SSL) and Secure Shell security (SSH)
OS independent hardware health status
IML and iLO Event Logging
Support for 12 user accounts with customizable access privilege
Intelligent
Manageability
HP Systems Insight Manager
SmartStart
ROM-Based Setup Utility (RBSU)
Remote-Flash Redundant ROM
Integrated Management Log (IML)
Server Health logging
Automatic Server Recovery-2 (ASR-2)
System Insight Display (SID)
Dynamic sector repairing and drive parameter tracking (with Smart Array controllers)
Hot Spare Boot
NOTE: Upon the event of a failed processor or VRM in a multi-processing environment, the
system will automatically reboot and use the remaining good processor(s).
Power Down Utility
Pre-Failure Warranty (covers processors, as well as SAS hard drives and memory)
Security
Power-on password
Keyboard password
Diskette drive control
Diskette boot control
QuickLock, Network Server Mode
Removable CD and Diskette Drive Assembly
Serial interface control
Administrator's password
Disk configuration lock
Integrated Lights-Out has 12 customizable user accounts and SSL encryption
Integrated Lights-Out can be disabled via a Global Setting
iLO Advance Pack supports directory services integration and two-factor authentication
Server Power Cords
High voltage power cord ships standard with all part numbers. Localized cables included with
geographic specific models in other world regions.
NOTE: ProLiant DL servers no longer ship standard with NEMA power cords (187335-001) that
allow connection to 110V US wall outlets in a home or office. ProLiant DL servers are primarily
connected to PDU's in data center racks so they now ship standard with only a PDU power cord
(416151-B21). If a user wishes to power a ProLiant DL server using a 110V receptacle (NEMA15), the above NEMA power cord must be ordered separately.
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
Page 8
QuickSpecs
HP ProLiant DL360 Generation 5
Standard Features
UPS Power Cord MatrixPlease see the UPS Power Cord Matrix for cable descriptions, requirements, and specifications
for UPS units:
ftp://ftp.compaq.com/pub/products/servers/proliantstorage/power-protection/powercordmatrix.pdf.
Power Supply
700W, Optional (1+ 1 redundant) power supply
NOTE:PN 399542-B21 contains the optional power supply and an IEC power cable only; purchase
if connecting to PDU/UPS that supports IEC cables. PN 399542-291 includes IEC power cable
and a Japan power cable.
System Fans
9 fans ship standard; N+1 fan redundancy standard
Required Cabling
For required cabling information, refer to the Web site at
http://h18000.www1.hp.com/products/servers/proliantdl360/.
OS Support
Microsoft Windows 2000 Server
Microsoft Windows Server 2003
Novell NetWare
Linux (Red Hat, SuSE)
Solaris 10 32/64-bit
VMware Virtualization Software
NOTE: SAS and SATA models may have different OS support. Please see OS Support Matrix.
NOTE: For a more complete and up-to-date listing of supported OSs and versions, please visit our
OS Support Matrix page at: http://www.hp.com/go/supportos.
NOTE: For more complete and up-to-date information on how to buy server operating systems
from HP please visit the OS product site at:
http://h18004.www1.hp.com/products/servers/software/OEM.html
NOTE: For a listing of the latest drivers available for the HP ProLiant DL360, please see:
http://h18023.www1.hp.com/support/files/server/us/index.html.
NOTE: For a more complete and up-to-date information on Linux support, please visit HP Linux
Web site at http://h18000.www1.hp.com/products/servers/linux/hpLinuxcert.html.
NOTE: For more information on HP's Certified and Supported ProLiant Servers, please visit the
VMware Server Support Matrix at:
http://h18004.www1.hp.com/products/servers/software/vmware/hpvmwarecert.html.
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
Page 9
QuickSpecs
HP ProLiant DL360 Generation 5
Standard Features
Rack Airflow
Requirements
Rack 10000 series Cabinets
The increasing power of new high-performance processor technology requires increased cooling
efficiency for rack-mounted servers. The 10000 Series Racks provide enhanced airflow for
maximum cooling, allowing these racks to be fully loaded with servers using the latest processors.
CAUTION: If a third-party rack is used, observe the following additional requirements to ensure
adequate airflow and to prevent damage to the equipment:
Front and rear doors: If your 42U server rack includes closing front and rear doors, you must
allow 830 square inches (5,350 sq cm) of hole evenly distributed from top to bottom to
permit adequate airflow (equivalent to the required 64 percent open area for ventilation).
Side: The clearance between the installed rack component and the side panels of the rack
must be a minimum of 2.75 inches (7 cm).
CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack.
This arrangement ensures proper airflow. Using a rack without blanking panels results in improper
cooling that can lead to thermal damage.
NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation
CD provided with the server, or to the server documentation located in the Support section at the
following URL: http://h18000.www1.hp.com/products/servers/proliantdl360/index.html.
Rack Kit
The HP ProLiant DL360 quick deploy rail system provides tool-free support for racks with square
or round mounting holes (including Compaq/HP 7000*, 9000, 10000 and HP series) with an
adjustment range to fit a rack depth of 21.25" to 37.75".
Telco Rack Support
HP ProLiant DL360 G5 Telco Rack Kit:
Support for all 2-post Telco racks requires the use of the standard rack kit and an additional option
kit from Rack Solutions (http://www.racksolutions.com/hp/)
Factory Express
Portfolio for Servers
and Storage
HP Factory Express offers configuration, customization, integration and deployment services for
HP servers and storage products. Customers can choose how their factory solutions are built,
tested, integrated, shipped and deployed.
Factory Express offers service packages for simple configuration, racking, installation, complex
configuration and design services as well as individual factory services, such as image loading,
asset tagging, and custom packaging. HP products supported through Factory Express include a
wide array of servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP
BladeSystem, HP 9000 servers as well as the MSA1000, VA7xxx, EVA, XP, rackable tape
libraries and configurable network switches.
For more information on Factory Express services for your specific server model please contact
your sales representative or go to http://www.hp.com/go/factory-express.
HP Enterprise
Configurator
The HP eCo-Enterprise Configurator now provides factory default racking for our HP hardware
portfolio. This approach is aligned with our strategic direction to meet the needs and expectations
of our valued customers. If you require "custom" rack configuration, please contact HP's Customer
Business Center or an Authorized Partner for assistance.
http://www.hp.com/products/configurator
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
Page 10
QuickSpecs
HP ProLiant DL360 Generation 5
Standard Features
HP ProLiant Smart
Buys (NA only)
The HP Smart Buy program offers mainstream business solutions at competitive prices with
excellent availability and superior HP quality. It offers a wide range of industry-leading HP
products at compelling prices, allowing you to receive richer configurations with additional options.
NOTE: ProLiant Smart Buys are available in North America only. For detailed specification
information on ProLiant Smart Buys please click on the following link:
ftp://ftp.compaq.com/pub/products/servers/smartbuys.pdf
Service and Support
This product is covered by a global limited warranty and supported by HP Services and a
worldwide network of resellers and service providers. Hardware diagnostic support and repair is
available for three years from date of purchase. Support for software and initial setup is available
for 90 days from date of purchase. Additional support may be covered under the warranty or
available for an additional fee. Enhancements to warranty services are available through HP Care
Pack services or customized service agreements.
NOTE: Server Warranty includes 3 year Parts, 3 year Labor, 3-year on-site support. Additional
information regarding worldwide limited warranty and technical support is available at:
http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html
HP Care Pack services include coverage for the HP branded hardware options qualified for the
server, purchased at the same time or afterward, internal to the enclosure, as well as 22" and
smaller external monitors and tower UPS options up to 3kVA; these items will be covered at the
same service level and for the same coverage period as the server. Coverage of UPS Battery is
not included, standard warranty terms & conditions apply. For servers or storage systems installed
within a rack, service also covers all HP qualified rack options installed within the same rack.
HP services provide continuous care and support expertise with committed response designed to
meet your IT and business needs.
To fully capitalizing on your HP ProLiant servers' capabilities requires a service partner who
thoroughly understands your server technology and systems environment. HP Services, an
industry leader in provision of multi vender support solutions provides a range of support services
designed to meet the varying needs of business. Whether an SMB or large global corporation HP
has a ProLiant server support offer to help you speedily deploy and maximize system uptime.
Enhanced Care – Minimum recommended service support offer designed to ensure customers
have access to expert assistance, whenever they need it.
4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years
Continuous Care – Recommended service delivering cost-effective support options designed to
extend HP Services committed response and guaranteed fix times, designed to speed problem
identification and resolution.
6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years
Total Care – Highest HP Support service level recommend to help increase IT performance and
availability with comprehensive, integrated hardware and software services
Support Plus 24 – Onsite HW support 24x7, 4hr response and Microsoft O/S SW Tech
support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays
Deployment Services – HP Installation and Start Up services designed to take time, risk, and
worry out of the deployment of ProLiant servers – and free customers IT support staff to focus on
what they do best, their business.
Installation & Start-Up of a ProLiant server and Microsoft or Linux O/S per the Customer
Description and/or Data Sheet. To be delivered on a scheduled basis 8am-5pm, M-F, excl.
HP holidays
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
Page 11
QuickSpecs
HP ProLiant DL360 Generation 5
Standard Features
NOTE: For a complete listing of service offerings and information visit:
http://www.hp.com/services/proliantservices
http://www.hp.com/go/proliant/carepack
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
Page 12
QuickSpecs
HP ProLiant DL360 Generation 5
Models
NOTE: ProLiant Smart Buys are available in NA only. For detailed specification information on ProLiant Smart Buys please
click on the following link: ftp://ftp.compaq.com/pub/products/servers/smartbuys.pdf.
Models
HP DL360 G5
Performance Models
Processor(s)
Two of the following
depending on Model
Quad-Core Models
DL360R05 E5345 4GB
435944-xx1
Dual-Core Models
DL360R05 5160 2GB
416566-xx1
DL360R05 5150 2GB
416564-xx1
HP DL360 G5 Base
Models
Cache Memory
One of the following
depending on Model
Memory
One of the following
depending on Model
Network Controller
2 GB (2 x 1 GB) Standard; PC2-5300 Fully Buffered DIMMs (DDR2-667)
4 GB (4 x 1 GB) Standard; PC2-5300 Fully Buffered DIMMs (DDR2-667)
Storage Controller
One of the following
depending on Model
Hard Drive
Internal Storage
Optical Drive
PCI-Express Slots
HP Smart Array P400i/256MB BBWC Controller (RAID 0/1/1+0/5/6)
512MB BBWC optional upgrade
Embedded NC373i Multifunction Gigabit Server Adapters
Power Supplies
No drives included; (6) drive bays active
876GB SAS; 360GB SATA
Slimline DVD/CD-RW Combo drive
1 full-length x8 PCI-Express slot
1 low-profile x8 PCI-Express slot
(2) 700W power supplies, redundant
Fans
Form Factor
9 total, redundancy standard
Rack (1U), (1.75 in/4.45 cm); 27.75 inch depth (70.5cm)
Processor(s)
One of the following
depending on Model
(1) Quad-Core Intel Xeon E5335 Processor (2.00 GHz, 80 Watts, 1333
FSB)
(1) Quad-Core Intel Xeon E5320 Processor (1.86 GHz, 80 Watts, 1066
FSB)
(1) Dual-Core Intel Xeon 5160 Processor (3.00 GHz, 80 Watts, 1333
FSB)
(1) Dual-Core Intel Xeon 5150 Processor (2.66 GHz, 65 Watts, 1333
FSB)
(1) Dual-Core Intel Xeon 5140 Processor (2.33 GHz, 65 Watts, 1333
FSB)
(1) Dual-Core Intel Xeon 5060 Processor (3.20 GHz, 130 Watts, 1066
FSB)
Quad-Core: 8MB (2 x 4MB) Level 2 cache; Intel Xeon Processor 5300
Sequence
Dual-Core: 4MB (1 x 4MB) Level 2 cache; Intel Xeon Processor 5100
Sequence
Dual-Core: 4MB (2 x 2MB) Level 2 cache; Intel Xeon Processor 5000
Sequence
Quad-Core Models
DL360R05 E5335 2GB
435943-xx1
DL360R05 E5320 1GB
438313-xx1
Dual-Core Models
DL360R05 5160 1GB
416565-xx1
DL360R05 5150 1GB
416563-xx1
DL360R05 5140 1GB
416562-xx1
DL360R05 5060 1GB
399519-xx1
(2) Dual-Core Intel Xeon 5160 Processor (3.00 GHz, 80 Watts, 1333
FSB)
(2) Dual-Core Intel Xeon 5150 Processor (2.66 GHz, 65 Watts, 1333
FSB)
(2) Quad-Core Intel Xeon E5345 Processor (2.33 GHz, 80 Watts, 1333
FSB)
Quad-Core: 8MB (2 x 4MB ) Level 2 cache; Intel Xeon Processor 5300
Sequence
Dual-Core: 4MB (1 x 4MB) Level 2 cache; Intel Xeon Processor 5100
Sequence
Cache Memory
One of the following
depending on Model
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
Page 13
QuickSpecs
HP ProLiant DL360 Generation 5
Models
Memory
One of the following
depending on Model
Network Controller
Storage Controller
Hard Drive
Internal Storage
Optical Drive
PCI-Express Slots
Power Supply
Fans
Form Factor
HP DL360 G5 Entry
Models
Processor(s)
One of the following
depending on Model
Quad-Core Models
DL360R05 E5310 1GB
438312-xx1
Dual-Core Models
DL360R05 5130 1GB
416561-xx1
DL360R05 5120 1GB
416560-xx1
DL360R05 5110 1GB
416559-xx1
Cache Memory
Memory
Network Controller
Storage Controller
Hard Drives
Internal Storage
Optical Drive
PCI-Express Slots
Power Supply
Fans
Form Factor
2 GB (2x1GB) Standard on E5335 Model; PC2-5300 Fully Buffered
DIMMs (DDR2-667)
1 GB (2 x 512 MB) Standard on E5320, 5140-5160, 5060 Models; PC25300 Fully Buffered DIMMs (DDR2-667)
Embedded NC373i Multifunction Gigabit Server Adapters
HP Smart Array P400i/256MB Controller (RAID 0/1/1+0/5) 512MB
BBWC or BBWC optional upgrades
No drives included; (4) drive bays active.
(6) bays supported with optional storage cable
(PN 399546-B21)
876GB SAS; 360GB SATA
Optional DVD, DVD/CD-RW, or Floppy
1 full-length x8 PCI-Express slot
1 low-profile x8 PCI-Express slot
(1) 700W power supply, redundant optional
9 total, redundancy standard
Rack (1U), (1.75 in/4.45 cm); 27.75 inch depth (70.5cm)
(1) Quad-Core Intel Xeon Processor E5310 (1.60 GHz 80 Watts, 1066
FSB)
(1) Dual-Core Intel Xeon 5130 Processor (2.00 GHz, 65 Watts, 1333
FSB)
(1) Dual-Core Intel Xeon 5120 Processor (1.86 GHz, 65 Watts, 1066
FSB)
(1) Dual-Core Intel Xeon 5110 Processor (1.6 GHz, 65 Watts, 1066
FSB)
Quad-Core: 8MB (2x4MB) Level 2 cache- Intel Xeon Processor 5300
Sequence
Dual-Core: 4MB (1 x 4MB) Level 2 cache - Intel Xeon Processor 5100
Sequence
1 GB (2 x 512 MB) Standard; PC2-5300 Fully Buffered DIMMs (DDR2667)
Embedded NC373i Multifunction Gigabit Server Adapters
HP Smart Array E200i/64MB Controller (RAID 0/1/1+0), 256MB BBWC
optional upgrade
No drives included; (4) drive bays active
876GB SAS; 360GB SATA
Optional DVD, DVD/CD-RW, or Floppy
1 full-length x8 PCI-Express slot
1 low-profile x8 PCI-Express slot
(1) 700W power supply, redundant optional
9 total, N+1 redundancy standard
Rack (1U), (1.75 in/4.45 cm); 27.75 inch depth (70.5cm)
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
Page 14
QuickSpecs
HP ProLiant DL360 Generation 5
Models
Country Code Key
XX=00
XX=20
XX=29
XX=37
XX=42
XX=AA
Rack Code Key
US
Brazil
Japan
APD
EURO
PRC
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
Page 15
QuickSpecs
HP ProLiant DL360 Generation 5
Configuration Information - Factory Integrated Models (North America only)
NOTE: For Configure to Order requirements within EMEA region, please consult local Sales Contact.
NOTE: HP does not allow factory integration of options into standard models listed above.
Configure-to-order servers must start with a CTO Chassis.
NOTE: This product offering does not support HP Factory Express Server Configuration Level 1.
NOTE: FIO indicates that this option only available as a Factory Installable Option.
Step 1: Base Configuration (choose one of the following configurable models)
Models
HP ProLiant DL360 G5 Rack CTO Chassis (North America)
Factory Integrated Model ships with:
Embedded NC373i Multifunction Gigabit Server Adapter
Integrated Lights-Out 2 (iLO 2) embedded
1 full-length and 1 low-profile x8 PCI-Express slots
9 fans; N+1 fan redundancy
(1) 700W power supply, redundant optional
Rack (1U), (1.75 in/4.45 cm)
399524-B21
Step 2: Choose Required Options (only one of the following from each list unless
otherwise noted)
Processors
Base Memory
Storage Controllers
Quad-Core Intel Xeon Processor X5355 - 2.66GHz, 120 Watts, 1333 FSB
Quad-Core Intel Xeon Processor E5345 - 2.33GHz, 80 Watts, 1333 FSB
Quad-Core Intel Xeon Processor E5335 - 2.00GHz, 80 Watts, 1333 FSB
Quad-Core Intel Xeon Processor E5320 – 1.86GHz, 80 Watts, 1066 FSB
Quad-Core Intel Xeon Processor E5310 – 1.60GHz, 80 Watts, 1066 FSB
Dual-Core Intel Xeon Processor 5160 – 3.00 GHz, 80 Watts, 1333 FSB
Dual-Core Intel Xeon Processor 5150 – 2.66 GHz, 65 Watts, 1333 FSB
Dual-Core Intel Xeon Processor 5148 – 2.33 GHz, 40 Watts, 1333 FSB
Dual-Core Intel Xeon Processor 5140 – 2.33 GHz, 65 Watts, 1333 FSB
Dual-Core Intel Xeon Processor 5130 – 2.00 GHz, 65 Watts, 1333 FSB
Dual-Core Intel Xeon Processor 5120 – 1.86 GHz, 65 Watts, 1066 FSB
Dual-Core Intel Xeon Processor 5110 – 1.60 GHz, 65 Watts, 1066 FSB
Dual-Core Intel Xeon Processor 5080 – 3.73 GHz, 130 Watts, 1066 FSB
Dual-Core Intel Xeon Processor 5060 – 3.20 GHz, 130 Watts, 1066 FSB
Dual-Core Intel Xeon Processor 5050 – 3.00 GHz, 95 Watts, 667 FSB
NOTE: If High Performance Model features are desired, 2nd processor is
included in the Performance Pack part numbers in Step 3 below.
1 GB FBD PC2-5300 2 x 512 MB Kit
2 GB FBD PC2-5300 2 x 1 GB Kit
4 GB FBD PC2-5300 2 x 2 GB Kit
8 GB FBD PC2-5300 2 x 4 GB Kit
Smart Array E200i controller for DL360 G5
NOTE: If selected, must choose one of the two cache modules below.
HP Smart Array E200 64MB FIO Cache
NOTE: Supports Smart Array E200 Controller only.
128MB Battery Backed Write Cache Enabler Option Kit
NOTE: Supports Smart Array E200i Controller.
Smart Array P400i controller for DL360 G5
NOTE: If selected, must choose one of the two cache modules below.
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
435956-L21
435954-L21
435952-L21
435950-L21
438314-L21
416579-L21
416577-L21
416575-L21
416573-L21
416571-L21
416569-L21
416567-L21
399540-L21
399536-L21
399532-L21
397409-B21
397411-B21
397413-B21
397415-B21
399548-B21
405102-B21
346914-B21
413741-B21
Page 16
QuickSpecs
HP ProLiant DL360 Generation 5
Configuration Information - Factory Integrated Models (North America only)
HP Smart Array P400 256MB Cache FIO
NOTE: Supports Smart Array P400 Controller and Smart Array P400i Controller
only.
512MB Battery-backed cache upgrade
NOTE: Supports Smart Array P400 Controller and Smart Array P400i Controller
only.
Battery-backed write cache upgrade (battery only)
NOTE: For Smart Array P400 Controller and Smart Array P400i Controller only.
HP Smart Array P600/256 BBWC Controller
NOTE: Requires PCI-X Riser option (PN 405154-B21).
NOTE: Requires HP SAS 4i to Mini SAS 4i 31 inch/.79 meter cable (PN 411100B21).
405139-B21
405148-B21
383280-B21
337972-B21
Step 3: Choose Additional Factory Integratable Options
Performance Packs
The HP ProLiant DL360 G5 performance packs are necessary to configure a HP
ProLiant DL360 G5 Performance Model. HP ProLiant DL360 G5 Performance
model includes the latest performance technologies and enterprise class
availability features pre-installed for convenience and value. The performance
pack includes a 2nd processor, redundant power supplies, Smart Array P400i
Controller with 256MB of BBWC, and storage cable to enable the all 6 disk drive
bays.
NOTE: 331903-B21 Slimline CD-RW/DVD-ROM Combo Drive Option Kit should
also be selected along with the Performance Pack skus below to achieve parity
to the HP ProLiant DL360 G5 Performance Models.
HP DL360G5 X5160 HPM FIO Perf Pack
HP DL360G5 X5150 HPM FIO Perf Pack
HP DL360G5 E5345 HPM FIO Perf Pack
430107-B21
431883-B21
435960-B21
Step 4: Choose Additional Options for Factory Integration
NOTE: For additional options, please refer to the "Options" section below.
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
Page 17
QuickSpecs
HP ProLiant DL360 Generation 5
Options
NOTE: Some options may not be factory integratable. Contact your local sales representative for additional information.
HP ProLiant DL360
Quad-Core Intel Xeon Processor X5355 (2.66 GHz, 120 Watts, 1333 FSB)
435956-B21
G5 Unique Options
Quad-Core Intel Xeon Processor E5345 (2.33 GHz, 80 Watts, 1333 FSB)
435954-B21
Quad-Core Intel Xeon Processor E5335 (2.00 GHz, 80 Watts, 1333 FSB)
435952-B21
Quad-Core Intel Xeon Processor E5320 (1.86 GHz, 80 Watts, 1066 FSB)
435950-B21
Quad-Core Intel Xeon Processor E5310 (1.60 GHz, 80 Watts, 1066 FSB)
438314-B21
Dual-Core Intel Xeon Processor 5160 (3.00 GHz, 80 Watts, 1333 FSB)
416579-B21
Dual-Core Intel Xeon Processor 5150 (2.66 GHz, 65 Watts, 1333 FSB)
416577-B21
Dual-Core Intel Xeon Processor 5148 (2.33 GHz, 40 Watts, 1333 FSB)
416575-B21
Dual-Core Intel Xeon Processor 5140 (2.33 GHz, 65 Watts, 1333 FSB)
416573-B21
Dual-Core Intel Xeon Processor 5130 (2.00 GHz, 65 Watts, 1333 FSB)
416571-B21
Dual-Core Intel Xeon Processor 5120 (1.86 GHz, 65 Watts, 1066 FSB)
416569-B21
Dual-Core Intel Xeon Processor 5110 (1.60 GHz, 65 Watts, 1066 FSB)
416567-B21
Dual-Core Intel Xeon Processor 5080 (3.73 GHz, 130 Watts, 1066 FSB)
399540-B21
Dual-Core Intel Xeon Processor 5060 (3.2 GHz, 130 Watts, 1066 FSB)
399536-B21
Dual-Core Intel Xeon Processor 5050 (3.0 GHz, 95 Watts, 667 FSB)
399532-B21
PCI-X Riser option
NOTE: To convert full-length PCI-Express slot to PCI-X slot.
Ambidextrous cable management arm
NOTE: Package contains two cable management arms
Fixed Cord Extension Bars for 1U servers (2 PDU sticks per kit)
700W HP redundant power supply with IEC cord only
700W HP redundant power supply with IEC cord and Japan cord (Japan)
ProLiant Essentials
Value Pack Software
ProLiant Essentials Accelerated iSCSI Pack
ProLiant Essentials Accelerated iSCSI Pack, Single License
NOTE: For additional Accelerated iSCSI Pack License Kits, please see the
QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/12466_div/12466_div.HTML
ProLiant Essentials Intelligent Networking Pack
ProLiant Essentials Intelligent Networking Pack – Windows Edition, Single
Server License
NOTE: For use with a single server. Contains one license with a unique license
activation key and documentation.
NOTE: For additional ProLiant Intelligent Networking Pack License Kits please
see the QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/12062_div/12062_div.HTML
ProLiant Essentials Intelligent Networking Pack – Linux Edition, Single Server
License
NOTE: For additional ProLiant Intelligent Networking Pack – Linux License Kits
please see the QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/12327_div/12327_div.HTML
ProLiant Essentials Performance Management Pack
ProLiant Essentials Performance Management Pack, No Media, Single-Server
License NOTE: This option kit includes 1 license with a unique license activation
key.
NOTE: The most recent version of the software can always be downloaded at
http://www.hp.com/products/pmp.
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
405154-B21
365403-B21
351655-B21
399542-B21
399542-291
407484-B22
436225-B21
436229-B21
436770-B21
Page 18
QuickSpecs
HP ProLiant DL360 Generation 5
Options
NOTE: For additional ProLiant Performance Management Pack License Kits
please see the QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/11925_div/11925_div.HTML
HP ProLiant Essentials Remote Directory Memory Access (RDMA) Pack
HP ProLiant Essentials RDMA Pack for Embedded Multifunction Gigabit Server
Adapters, 1 License
HP ProLiant Essentials RDMA Pack for Standup Multifunction Gigabit Server
Adapters, 1 License
NOTE: For additional ProLiant Essentials RDM Pack License Kits please see the
QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/12573_div/12573_div.HTML
ProLiant Essentials Rapid Deployment Pack
Rapid Deployment Pack, Single-Server License
NOTE: This license allows 1 server to be deployed and managed via RDP.
Rapid Deployment Pack, Single-Server License (Japan)
NOTE: This license allows 1 server to be deployed and managed via RDP.
NOTE: For additional ProLiant Essentials Rapid Deployment Pack License Kits
please see the QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/11053_div/11053_div.HTML
ProLiant Essentials Workload Management Pack
ProLiant Essentials Workload Management Pack, Single Server License
NOTE: For additional ProLiant Workload Management Pack License Kits please
see the QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/11452_div/11452_div.HTML
ProLiant Essentials Virtualization Management Software
ProLiant Essentials Virtual Machine Management Pack, Single-Server License
NOTE: For use with a single server. Contains one license with a unique license
activation key and documentation.
ProLiant Essentials Server Migration Pack, Single-Migration License
NOTE: Contains one license, enabling 1 server migration, with a unique license
activation key and documentation.
NOTE: For additional ProLiant Essentials Virtualization Management Software
License Kits please see the QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/12328_div/12328_div.HTML
NOTE: This license allows 1 server to be migrated from a physical server to a
virtual machine. Or this license can be used to migrate a virtual machine from
one virtualization layer i.e. VMware GSX to a different virtualization layer such as
VMware ESX or Microsoft Virtual Server 2005.
ProLiant Essentials Physical to ProLiant Edition
ProLiant Essentials Server Migration Pack - Physical to ProLiant Edition, SingleMigration License
NOTE: For additional ProLiant Essentials Server Migration License Kits please
see the QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/12467_div/12467_div.HTML
ProLiant Essentials Vulnerability and Patch Management Pack
ProLiant Essentials Vulnerability and Patch Management Pack, Single-Server
License
NOTE: For use with a single server. Contains one license with a unique license
activation key and documentation.
NOTE: For additional ProLiant Vulnerability and Patch Management Pack
License Kits, please see the QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/12111_div/12111_div.HTML
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
407478-B22
407481-B22
267196-B21
267196-291
303284-B21
435661-B21
435663-B21
412978-B21
371645-B21
Page 19
QuickSpecs
HP ProLiant DL360 Generation 5
Options
NOTE: Flexible and volume quantity license kits are available for ProLiant
Essentials Value Packs. Refer to http://www.hp.com/servers/proliantessentials or
the various ProLiant Essentials Value Pack product QuickSpecs for more
information.
NOTE: For more information regarding ProLiant Essentials Software, please see
the following URL: http://www.hp.com/servers/proliantessentials.
Remote Management Integrated Lights-Out Advanced Pack
ProLiant Essentials Integrated Lights-Out Advanced Pack, 1 server
Featuring: Sophisticated virtual administration features for ultimate control of
servers in the data centers and remote sites.
NOTE: For additional Integrated Lights-Out Advanced Pack License Kits please
see the QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/11052_div/11052_div.HTML
HP Integrated Lights-Out (iLO) Power Management Pack
HP iLO Power Management Pack, No Media Single-Server License
NOTE: This option kit includes 1 license for iLO Advanced and Insight Power
Manager.
NOTE: For additional Integrated Lights-Out Power Management Pack License
Kits please see the QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/12632_div/12632_div.HTML
HP Insight Control Environment
HP Insight Control Environment , No Media 1 License
NOTE: For additional Insight Control Environment License Kits please see the
QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/12631_div/12631_div.HTML
HP Insight Power Manager (IPM)
HP Insight Power Manager Pack, No Media, Single-Server License
NOTE: This option kit includes 1 license for Insight Power Manager.
NOTE: For additional Insight Power Manager License Kits please see the
QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/12623_div/12623_div.HTML
ProLiant Software
Maintenance
Subscription
ProLiant Software Maintenance Single Release
ProLiant Foundation Pack Single Release
NOTE: Please see the SmartStart QuickSpecs for additional information
regarding the subscription purchase:
http://h18000.www1.hp.com/products/quickspecs/Division/11073.html
(Worldwide)
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
263825-B21
436210-B21
436214-B21
433691-B21
356573-B21
356604-B21
Page 20
QuickSpecs
HP ProLiant DL360 Generation 5
Options
Processor
Quad-Core Intel Xeon Processor X5355 (2.66 GHz, 120 Watts, 1333 FSB)
Quad-Core Intel Xeon Processor E5345 (2.33 GHz, 80 Watts, 1333 FSB)
Quad-Core Intel Xeon Processor E5335 (2.00 GHz, 80 Watts, 1333 FSB)
Quad-Core Intel Xeon Processor E5320 (1.86 GHz, 80 Watts, 1066 FSB)
Quad-Core Intel Xeon Processor E5310 (1.60 GHz, 80 Watts, 1066 FSB)
Dual-Core Intel Xeon Processor 5160 (3.00 GHz, 80 Watts, 1333 FSB)
Dual-Core Intel Xeon Processor 5150 (2.66 GHz, 65 Watts, 1333 FSB)
Dual-Core Intel Xeon Processor 5148 (2.33 GHz, 40 Watts, 1333 FSB)
Dual-Core Intel Xeon Processor 5140 (2.33 GHz, 65 Watts, 1333 FSB)
Dual-Core Intel Xeon Processor 5130 (2.00 GHz, 65 Watts, 1333 FSB)
Dual-Core Intel Xeon Processor 5120 (1.86 GHz, 65 Watts, 1066 FSB)
Dual-Core Intel Xeon Processor 5110 (1.60 GHz, 65 Watts, 1066 FSB)
Dual-Core Intel Xeon Processor 5080 (3.73 GHz, 130 Watts, 1066 FSB)
Dual-Core Intel Xeon Processor 5060 (3.2 GHz, 130 Watts, 1066 FSB)
Dual-Core Intel Xeon Processor 5050 (3.0 GHz, 95 Watts, 667 FSB)
435956-B21
435954-B21
435952-B21
435950-B21
438314-B21
416579-B21
416577-B21
416575-B21
416573-B21
416571-B21
416569-B21
416567-B21
399540-B21
399536-B21
399532-B21
Memory (DIMMs)
1 GB FBD PC2-5300 2 x 512 MB Kit
2 GB FBD PC2-5300 2 x 1 GB Kit
4 GB FBD PC2-5300 2 x 2 GB Kit
8 GB FBD PC2-5300 2 x 4 GB Kit
397409-B21
397411-B21
397413-B21
397415-B21
Optical Drives
Slimline CD-RW/DVD-ROM Combo Option Kit
Slimline DVD-ROM Drive (8X/24X) Option Kit
HP DVD+R/RW 8X Slim
Slimline CD-ROM Drive 24X
331903-B21
264007-B21
383975-B21
356963-B21
Diskette Drive
Slimline Ejectable Floppy drive
390164-B21
Hard Drives
Serial Attached SCSI (SAS) SFF Hot Plug
HP 36GB 3G SAS 10K SFF SP HDD
HP 36GB 3G SAS 15K SFF SP HDD
HP 72GB 3G SAS 10K SFF SP HDD
HP 72GB 3G SAS 15K SFF SP HDD
HP 146GB 3G SAS 10K SFF SP HDD
NOTE: Please see the SAS Hard Drive QuickSpecs for Technical Specifications
such as capacity, height, width, interface, transfer rate, seek time, physical
configuration, and operating temperature:
http://h18000.www1.hp.com/products/quickspecs/12244_div/12244_div.HTML
(Worldwide)
SFF SATA Hot Plug
HP 60GB 1.5G SATA 5.4K SFF HDD
NOTE: SATA drives have a 1 year warranty. Please see the SATA Hard Drive
QuickSpecs for Technical Specifications such as capacity, height, width,
interface, transfer rate, seek time, physical configuration, and operating
temperature:
http://h18000.www1.hp.com/products/quickspecs/12091_div/12091_div.HTML
(Worldwide)
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
375859-B21
431933-B21
375861-B21
431935-B21
431958-B21
379306-B21
Page 21
QuickSpecs
HP ProLiant DL360 Generation 5
Options
Storage Controllers
SAS Controllers
Smart Array E200i Controller
128-MB Battery-Backed Write Cache (BBWC)
NOTE: Supports Smart Array E200i Controller only.
Smart Array P400i Controller
HP Smart Array P400i/256MB Controller
Battery-backed write cache upgrade
NOTE: For Smart Array P400 Controller and Smart Array P400i Controller only.
512MB Battery-backed cache upgrade
NOTE: For Smart Array P400 Controller and Smart Array P400i Controller only.
Smart Array P600 Controller
HP Smart Array P600/256 BBWC Controller
NOTE: Requires DL360 G5 PCI-X conversion kit (PN 405154-B21).
512 MB Battery-Backed Cache Upgrade
NOTE: This 512-MB Battery-Backed Cache Module upgrade kit supports the
Smart Array P600 Controller and the Smart Array 6400 series Controller.
Smart Array P800 Controller
HP Smart Array P800/512 BBWC Controller
NOTE: Please see the following Controller QuickSpecs for additional
information:
http://h18000.www1.hp.com/products/quickspecs/12460_div/12460_div.HTML
(Smart Array E200 Controller)
http://h18000.www1.hp.com/products/quickspecs/12400_div/12400_div.HTML
(Smart Array P400 Controller)
http://h18000.www1.hp.com/products/quickspecs/12247_div/12247_div.HTML
(Smart Array P600 Controller)
http://h18000.www1.hp.com/products/quickspecs/12616_div/12616_div.HTML
(Smart Array P800 Controller)
SAS HBA
HP 8 Internal Port SAS HBA with RAID
NOTE: Supports SAS and SATA disk drive. RAID 0,1 supported.
NOTE: Please see the HBA QuickSpecs for additional information:
http://h18004.www1.hp.com/products/quickspecs/12332_div/12332_div.html
(8 Internal Port SAS HBA)
SAS Cables
HP Mini SAS 4i 13.4 inch/0.35 m cable
NOTE: Used to connect Smart Array P400i Controller to DL360 G5 5th and 6th
drive bays.
HP SAS 4i to Mini SAS 4i 31 inch/.79 meter cable
NOTE: Used to connect SA-P600, SA-P400, SA-E200 Controllers to the HP
ProLiant DL360 G5 drive backplane. This kit supports all six drive bays.
SCSI Controllers for External Drive/Storage Support
Smart Array 6402/128 Controller
NOTE: For support of external drives only.
Smart Array 6404/256 Controller
NOTE: For support of external drives only.
Smart Array 642 Controller
NOTE: For support of external drives only.
128MB Battery-Backed Cache Enabler
NOTE: This 128-MB Battery-Backed Cache Module upgrade kit supports the
Smart Array 642 Controller.
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
346914-B21
399550-B21
383280-B21
405148-B21
337972-B21
372538-B21
381513-B21
347786-B21
399546-B21
411100-B21
273915-B21
273914-B21
291967-B21
351580-B21
Page 22
QuickSpecs
HP ProLiant DL360 Generation 5
Options
Communications
Tape Drives
512 MB Battery-Backed Cache Upgrade
NOTE: This 512-MB Battery-Backed Cache Module upgrade kit supports the
Smart Array P600 Controller and the Smart Array 6400 series Controller.
64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2
SCSI HBA
HP SC11Xe Host Bus Adapter
NOTE: Please see the QuickSpecs for additional information:
http://h18000.www1.hp.com/products/quickspecs/10429_div/10429_div.HTML
(SCSI Adapter)
http://h18000.www1.hp.com/products/quickspecs/11555_div/11555_div.HTML
(U320 Adapter)
http://h18000.www.1.hp.com/products/quickspecs/11943_div/11943_div.HTML
(U320 SCSI HBA)
http://h18000.www1.hp.com/products/quickspecs/12566_div/12566_div.HTML
(SC11Xe HBA)
372538-B21
HP NC150T PCI 4-port Gigabit 1000T Combo Switch Adapter
HP NC310F PCI-X 1000SX Gigabit Server Adapter
367132-B21
368169-B21
HP NC320T PCI Express 1000T Gigabit Server Adapter
HP NC340T PCI-X 4-port 1000T Gigabit Server Adapter
HP NC360T PCI Express Dual Port Gigabit Server Adapter
HP NC373F PCI Express Multifunction Gigabit Server Adapter
HP NC373T PCI Express Multifunction Gigabit Server Adapter
HP NC380T PCI Express Dual Port Multifunction Gigabit Server Adapter
HP NC510F PCIe 10 Gigabit Server Adapter
NOTE: A minimum of 1 gigabyte (1 GB) of server memory is required per each
NC510F adapter.
HP NC510C PCIe 10 Gigabit Server Adapter
NOTE: A minimum of 1 gigabyte (1 GB) of server memory is required per each
NC510C adapter.
HP NC1020 PCI 1000T Gigabit Server Adapter
NOTE: Any NIC (except the NC1020) on the option list can be used for
redundancy with the embedded Dual NC373i Multifunction Gigabit NICs. When
teaming with other NICs or with the embedded NIC, the lack of Jumbo Frames
and LSO features on the NC1020 will cause high end NICs to have those
features disabled.
HP IB 4X SDR PCI-e single PORT HCA
HP IB 4X DDR PCI-e Single PORT HCA
Agere 06 PCI Hi-Speed 56K SftMd
367047-B21
391661-B21
412648-B21
394793-B21
394791-B21
394795-B21
414126-B21
374654-B21
412911-B21
414129-B21
353377-B21
431038-B21
431039-B21
440519-B21
NOTE: For the complete listing of Tape Drive offerings, please see:
http://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html
For recommended tape drive offerings for this ProLiant server see the following:
USB Tape Drives
HP StorageWorks DAT 40 USB Internal Tape Drive (Carbonite)
NOTE: HP recommends combining this tape drive with the 1U USB Rack-Mount
kit (A8007A) for a complete rack-mount solution.
HP StorageWorks 1U USB Rack-Mount Kit with one DAT 72 USB Tape Drive
SAS Tape Drives
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
DW022A
AG594A
Page 23
QuickSpecs
HP ProLiant DL360 Generation 5
Options
NOTE: Connecting hard drive cage and SAS tape to the same SAS Controller
using split cable (supplied with tape drive) deactivates 1 of the hard drive bays.
Actual hard drive bay deactivated depends on where split cable plugs into SAS
drive connector. Example: 3x SAS cable connector plugged into SAS drive
connector (5-8) on the back of the hard drive cage would mean drive bay 8 is
deactivated.
HP StorageWorks Ultrium 448 SAS Internal Tape Drive
NOTE: HP recommends combining this tape drive with the 1U SAS Rack-Mount
kit (AE459A) for a complete rack-mount solution.
HP StorageWorks Ultrium 920 SAS Internal Tape Drive
NOTE: HP recommends combining this tape drive with the 1U SAS Rack-Mount
kit (AE459A) for a complete rack-mount solution.
NOTE: Please refer to the "Tape Drives, Tape Autoloaders & Tape Libraries"
table in the Storage section of this document for a list of SAS controllers with
tape support.
Ultrium Tape Drives
HP StorageWorks Ultrium 232 Internal Tape Drive (Carbonite)
NOTE: HP recommends combining this tape drive with the 1U SCSI Rack-Mount
kit (A7445B) for a complete rack-mount solution.
HP StorageWorks 1U Rack-mount kit with one Ultrium 448 (Carbonite)
HP StorageWorks 1U SCSI Rack-mount kit with one Ultrium 920
NOTE: Please see the HP StorageWorks Ultrium Tape Drive QuickSpecs for
additional options such as controllers, media, and other related items:
http://h18006.www1.hp.com/products/quickspecs/11739_div/11739_div.html
(Worldwide)
http://h18006.www1.hp.com/products/quickspecs/12128_div/12128_div.html
(Worldwide)
For an up-to-date listing of the latest O/S and software support details for HP
Ultrium tape drives, please visit: http://www.hp.com/go/connect
DAT Drives
HP StorageWorks DAT 72 SCSI Internal Tape Drive (Carbon)
NOTE: HP recommends combining this tape drive with the 1U SCSI Rack-Mount
kit (A7445B) for a complete rack-mount solution.
NOTE: Please see the DAT Tape Drive QuickSpecs for controllers, media, and
other options:
http://h18000.www1.hp.com/products/quickspecs/11883_div/11883_div.HTML
(Worldwide)
For an up-to-date listing of the latest O/S and software support details for HP
DAT drives, please visit: http://www.hp.com/go/connect
Rack-Mount Tape Drive Enclosures
HP StorageWorks 1U SCSI Rack-Mount kit
NOTE: The 1U Rack-Mount Kit can support up to (2) half-height tape drives and
is compatible with multiple Single-Ended and LVD SCSI tape drives including the
DAT 24, DAT 40, DAT 72, DLT VS80, DLT VS160, Ultrium 215, Ultrium 232,
Ultrium 448 and Ultrium 920 tape drives.
HP StorageWorks 1U USB Rack-Mount Kit
NOTE: The 1U USB Rack-Mount Kit can support up to (2) half-height tape drives
and is compatible with the DAT 24 USB, DAT 40 USB and DAT 72 USB tape
drives.
HP StorageWorks 1U SAS Rack-Mount Kit
NOTE: The 1U SAS Rack-Mount Kit can support up to (2) half-height tape drives
and is compatible with the Ultrium 448 SAS tape drive.
NOTE: Connecting hard drive cage and SAS tape to the same SAS Controller
using split cable (supplied with tape drive) deactivates 1 of the hard drive bays.
Actual hard drive bay deactivated depends on where split cable plugs into SAS
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
DW085A
EH847A
DW064A
DW028B
EH903A
Q1522B
A7445B
A8007A
AE459A
Page 24
QuickSpecs
HP ProLiant DL360 Generation 5
Options
drive connector. Example: 3x SAS cable connector plugged into SAS drive
connector (5-8) on the back of the hard drive cage would mean drive bay 8 is
deactivated.
NOTE: Please see the Rack-Mount Tape Drive Kits QuickSpecs for additional
information regarding these kits:
http://h18000.www1.hp.com/products/quickspecs/10854_div/10854_div.HTML
(Worldwide)
Tape Autoloaders
Tape Libraries
HP StorageWorks DAT Autoloader
HP StorageWorks DAT 72x10 tape autoloader
HP StorageWorks 1/8 Tape Autoloader
HP StorageWorks 1/8 Ultrium 960 Tape Autoloader
HP StorageWorks 1/8 Ultrium 920 G2 Tape Autoloader
HP StorageWorks 1/8 Ultrium 448 G2 Tape Autoloader
HP StorageWorks 1/8 Ultrium 232 G2 Tape Autoloader
HP StorageWorks 1/8 G2 Tape Autoloader Rack Kit
NOTE: Required to install the 1/8 G2 Autoloaders in a standard 19-inch rack;
includes rails and rackmount instructions
1/8 Tape Autoloader Rackmount Kit
NOTE: Required to install the 1/8 tape autoloader in a standard 19-inch rack.
NOTE: Please reference the Autoloader QuickSpecs at
http://www.hp.com/go/automation for additional information needed to create a
complete solution; reference current compatibility information at
http://www.hp.com/go/ebs.
HP StorageWorks MSL2024 Tape Library
HP StorageWorks MSL2024 1 Ultrium 960 Drive Library
HP StorageWorks MSL2024 1 Ultrium 960 4GB FC Library
HP StorageWorks MSL2024 1 Ultrium 920 Drive Library
HP StorageWorks MSL2024 2 Ultrium 920 Drive Library
HP StorageWorks MSL2024 1 Ultrium 448 Drive Library
HP StorageWorks MSL2024 2 Ultrium 448 Drive Library
HP StorageWorks MSL4048 Tape Library
HP StorageWorks MSL4048 1 Ultrium 448 Drive Library
HP StorageWorks MSL4048 2 Ultrium 448 Drive Library
HP StorageWorks MSL4048 1 Ultrium 920 Drive Library
HP StorageWorks MSL4048 2 Ultrium 920 Drive Library
HP StorageWorks MSL4048 1 Ultrium 960 Drive Library
HP StorageWorks MSL4048 1 Ultrium 960 4GB FC Library
HP StorageWorks MSL4048 2 Ultrium 960 Drive Library
HP StorageWorks MSL4048 2 Ultrium 960 4GB FC Library
HP StorageWorks MSL6000 Tape Library
Ultrium 960 technology
HP StorageWorks MSL6030 1 Ultrium 960 Dr LVDS Library
HP StorageWorks MSL6030 1 Ultrium 960 Dr FC Library
HP StorageWorks MSL6030 2 Ultrium 960 Dr LVDS Library
HP StorageWorks MSL6030 2 Ultrium 960 Dr FC Library
Ultrium 460 technology
HP StorageWorks MSL6030 1 Ultrium 460 Dr LVDS Library
HP StorageWorks MSL6030 1 Ultrium 460 Dr FC Library
HP StorageWorks MSL6030 2 Ultrium 460 Dr LVDS Library
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
AE313A
AF204A
AH165A
AH164A
AH163A
AH166A
C9268R
AG115A
AG326B
AH169A
AH170A
AG116A
AG117A
AG320A
AG321A
AH171A
AH172A
AG322A
AG324B
AG323A
AG325B
AD606B
AD608B
AD607B
AD609B
AD598B
AD600B
AD599B
Page 25
QuickSpecs
HP ProLiant DL360 Generation 5
Options
HP Data Protector
Express Software
HP StorageWorks MSL6030 2 Ultrium 460 Dr FC Library
NOTE: Please reference the MSL2024, MSL4048 and MSL6000 Tape Library
QuickSpecs at http://www.hp.com/go/automation for additional information
needed to create a complete solution; reference current compatibility information
at http://www.hp.com/go/ebs.
AD601B
HP DP Express Backup Server Upgrade for ProLiant Software
HP DP Express Package for Microsoft Small Business Server
NOTE: To obtain a free licensed copy of HP Data Protector Express for ProLiant
edition software, please visit the "Protect Your Data" link accessible from your
ProLiant server's System Management Homepage (SMH) software (SmartStart
7.5 or later).
BB117AP
BB118AA
NOTE: Please see the HP Data Protector Express QuickSpecs for additional
information regarding the purchase of HP Data Protector Express software:
http://h18000.www1.hp.com/products/quickspecs/12337_div/12337_div.html
(Worldwide)
HP StorageWorks
HP StorageWorks Modular Smart Array 20
Modular Smart Array 20NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity,
redundant power supplies.
HP StorageWorks Modular Smart Array 20 Starter Kit
NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity,
redundant power supplies. Includes Smart Array 6402/128 Controller.
NOTE: The Modular Smart Array Enclosure 20 Family supports the SATA
1.5Gb/s 3.5” Hot Plug Hard Drives.
335921-B21
HP StorageWorks
HP StorageWorks Modular Smart Array 30 SB
Modular Smart Array 30NOTE: Rack-mountable 14 drive enclosure with single bus, redundant power
supplies
HP StorageWorks Modular Smart Array 30 DB
NOTE: Rack-mountable 14 drive enclosure with dual bus, redundant power
supplies
NOTE: The Modular Smart Array Enclosure 30 Family supports the Wide Ultra3,
Ultra320 Hot Plug Hard Drives.
302969-B21
HP StorageWorks
HP StorageWorks Modular Smart Array 50 Enclosure
Modular Smart Array 50NOTE: Please see the Modular Smart Array 50 QuickSpecs for additional
information including configuration steps and additional options needed for a
complete solution at:
http://h18000.www1.hp.com/products/quickspecs/12245_div/12245_div.HTML
(Worldwide)
364430-B21
HP StorageWorks
Modular Smart Array
500
335880-B21
HP StorageWorks Modular Smart Array 500 Generation 2
NOTE: Please see the Modular Smart Array 500 Generation 2 QuickSpecs for
additional information including configuration steps and additional options
needed for a complete solution at:
http://h18000.www1.hp.com/products/quickspecs/11956_div/11956_div.HTML
(Worldwide)
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
366172-B21
302970-B21
Page 26
QuickSpecs
HP ProLiant DL360 Generation 5
Options
HP StorageWorks
Modular Smart Array
1000
HP StorageWorks Modular Smart Array 1000
NOTE: Please see the Modular Smart Array 1000 QuickSpecs for additional
options and configuration information at:
http://h18000.www1.hp.com/products/quickspecs/11033_div/11033_div.HTML
(Worldwide)
HP StorageWorks
Modular Smart Array
1500 cs
Modular Smart Array 1500 Controller Shelf
NOTE: Please see the StorageWorks Modular SAN Array 1500 cs QuickSpecs
for additional options and configuration information at:
http://www.hp.com/go/MSA1500cs
Cluster Options
ProLiant Cluster Starter Kit
NOTE: For additional information regarding the ProLiant Cluster Starter Kit
please see the following QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/11935_div/11935_div.html
(Worldwide)
HP HA/F200 for Entry SAN Cluster
NOTE: For additional information regarding the ProLiant Cluster for Entry Level
SAN please see the following QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/11932_div/11932_div.html
(Worldwide)
NOTE: For configuration/certification options for the HP Parallel Database
Cluster for Oracle RAC please go to:
http://www.hp.com/solutions/highavailability/oracle
HP Serviceguard for Linux ProLiant Cluster A.11.16 for SUSE SLES 9 & 10 and
Red Hat EL 3 & 4 (2 node license cluster kit)
HP Serviceguard for Linux A.11.16 for SUSE SLES 9 & 10 and Red Hat EL 3 &
4 (single license version)
HP Serviceguard for Linux and Red Hat Global File System - 1 year subscription
HP Serviceguard for Linux and Red Hat Global File System - 3 years
subscription
NOTE: For additional information regarding HP Serviceguard for Linux, please
see the following QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/11518_div/11518_div.html
(Worldwide)
NOTE: For configuration/certification options for HP Serviceguard for Linux
please go to: http://www.hp.com/info/sglx
StorageWorks
Options
NOTE: The following is a list of all Fibre Channel Host Bus Adapters for
Windows and Linux. For detailed compatibility information please see:
http://h18006.www1.hp.com/storage/saninfrastructure/hba.html
HP StorageWorks FC2142SR 4Gb PCI-e HBA
HP StorageWorks FC2242SR Dual Channel 4 Gb PCI-e HBA
HP StorageWorks FC1142SR 4Gb PCI-e HBA
HP StorageWorks FC1242SR Dual Channel 4 Gb PCI-e HBA
HP StorageWorks FC2143 4Gb PCI-X 2.0 -to-Fibre Channel HBA
HP StorageWorks FC2243 Dual Channel 4Gb PCI-X 2.0 HBA
HP StorageWorks FC1143 4Gb PCI-X 2.0 HBA
HP StorageWorks FC1243 Dual Channel 4Gb PCI-X 2.0 HBA
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
201723-B22
AA986A
364023-B22
364026-B22
305199-B26
307754-B26
T2798AA#001
T2798AA#003
A8002A
A8003A
AE311A
AE312A
AD167A
AD168A
AB429A
AE369A
Page 27
QuickSpecs
HP ProLiant DL360 Generation 5
Options
Uninterruptible Power HP, R1.5kVA UPS, 1U, NA
Systems – Rack
HP, R1.5kVA UPS, 1U, INTL
Mountable
HP, R1.5kVA UPS, 1U, JPN/TW
HP R3000 VA UPS, 2U, DTC, INTL
HP R3000 VA UPS, 2U, L5-30, NA
HP R3000 VA UPS, 2U, L6-20, NA
HP R3000 VA UPS, 2U, L6-20, JPN
HP R3000 VA UPS, 2U, L5-30, JPN
HP R5500 VA UPS, INTL
HP R5500 VA UPS, NA/JPN
Power Cords
AF419A
AF418A
AF421A
AF414A
AF422A
AF423A
AF424A
AF425A
AF416A
AF426A
NOTE: The HP ProLiant DL360 G5 ships with an IEC-IEC power cord used for
rack mounting with Power Distribution Units (PDUs).
Nema 5-15P to IEC320-C13
Power Cord, Euro, 10A 250 V Straight (12 ft/3.7 m)
Power Cord, UK, 10A 250 V Straight (12 ft/3.7 m)
AF556A
157215-021
157216-031
Power Cord, Danish, 10A 250 V Straight (12 ft/3.7 m)
Power Cord, Swiss, 10A 250 V Straight (12 ft/3.7 m)
Power Cord, Italian, 10A 250 V Straight (12 ft/3.7 m)
Power Cord, South Africa, 10A 250 V Straight (12 ft/3.7 m)
157218-081
157219-111
157217-061
157220-AR1
HP Monitored Power HP Monitored Power Distribution Unit: Full Rack Version
Distribution Unit (PDU) 17.3 kVA Monitored PDU Model S2324
8.6 kVA Monitored PDU Model S1324
16.6 kVA Monitored PDU Model S2140
8.3 kVA Monitored PDU Model S1140
22 kVA Monitored PDU Model S2316
11 kVA Monitored PDU Model S1316
14.7 kVA Monitored PDU Model S2132
7.3 kVA Monitored PDU Model S1132
4.9kVA Monitored PDU model S124
7.3kVA Monitored PDU model S132
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
AF503A
AF504A
AF505A
AF506A
AF507A
AF508A
AF509A
AF510A
AF914A
AF915A
Page 28
QuickSpecs
HP ProLiant DL360 Generation 5
Options
Modular PDUs 1U/0U
(Up to 32 outlets)
NOTE: 1U/0U mounting
brackets shipped with
the unit (optimized for
10000 and 9000 series
racks).
Fixed Cord Extension Bars
NOTE: Two extension bar sticks; each with (7) C13 plugs.
Fixed Cord PDU (NA/JPN)
NOTE: Four Fixed Cord Extension Bars, and one 24A, HV mPDU L6-30P core.
Fixed Cord PDU (INTL)
NOTE: Four Fixed Cord Extension Bars, and one 32A, HV mPDU IEC-309 core.
HP Modular Power Distribution Units (mPDU), Low Volt Model, 24A (100-127
VAC) (NA, Japan)
NOTE: This mPDU (252663-D71) may also be used to connect the low volt
model of the UPS R3000 XR.
HP Modular Power Distribution Units (mPDU), High Volt Model, 24A (200-240
VAC) (NA, Japan)
HP Modular Power Distribution Units (mPDU), High Volt Model, 32A (200-240
VAC) (Int’l)
HP Modular Power Distribution Units (mPDU), High Volt Model, 40A (200-240
VAC) (WW)
NOTE: This mPDU (252663-B21), 40A model has a hardwired input.
HP Modular Power Distribution Unit(mPDU), High Volt Model, 16A (200-240
VAC) (WW)
HP Modular Power Distribution Unit (mPDU), High Volt Model, 40A, Attached
Cord, (NA/JPN)
HP Modular Power Distribution Unit (mPDU), High Volt Model, 40A, Attached
Cord, (Int'l)
NOTE: This PDU has a detachable input power cord and allows for adaptability
to country specific power requirements. This model may also be used with the
high volt UPSs R3000 XR and R6000 For North America, need to order cable
PN 340653-001.
NOTE: Please see the following Modular Power Distribution Unit (Zero-U/1U
Modular PDUs) QuickSpecs for additional options including shorter jumper
cables and country specific power cords:
http://h18000.www1.hp.com/products/quickspecs/11041_div/11041_div.HTML
(Worldwide)
351655-B21
USB Options
HP USB 2-Button Optical Scroll Mouse (Carbonite/Silver)
HP USB 04 Standard Keyboard
USB 2.0 4-port HUB
HP 1GB Drive Key II – USB 2.0 Flash Drive
HP 512MB DriveKey II – USB Flash Drive
DC172B
DT528A#xxx
DG954A
AG382AA
ED516AA
HP ProLiant DL360
G5 Deployment
Options
700W HP redundant power supply with IEC cord only
399542-B21
700W HP redundant power supply with IEC cord and Japan cord (Japan)
399542-291
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
351655-D72
351655-B31
252663-D71
252663-D72
252663-B31
252663-B21
252663-B24
252663-D73
252663-B32
Page 29
QuickSpecs
HP ProLiant DL360 Generation 5
Options
HP Rack 5000 Series
(Graphite Metallic)
HP 5642 Rack Unassembled
NOTE: Please see the HP Rack 5642 QuickSpecs for additional part numbers
and Technical Specifications such as height, width, depth, weight, and color:
http://h18000.www1.hp.com/products/quickspecs/12074_div/12074_div.HTML
(Worldwide)
NOTE: For additional information regarding Rack Cabinets, please see the
following URL: http://www.hp.com/go/rackandpower.
HP Rack 10000 G2
Series
(Carbon/Graphite
Metallic)
10642 G2 (42U) Rack Cabinet – Pallet
10642 G2 (42U) Rack Cabinet – Shock Pallet
10642 G2 (42U) Rack Cabinet – Crated
10642 G2 (42U) Rack Cabinet, with Extension – Shock Pallet
10636 G2 (36U) Rack Cabinet – Pallet
10636 G2 (36U) Rack Cabinet – Shock Pallet
10636 G2 (36U) Rack Cabinet – Crated
10636 G2 (36U) Rack Cabinet, with Extension – Shock Pallet
NOTE: It is mandatory to use a shock pallet when shipping racks with equipment
installed.
NOTE: Please see the Rack 10000 G2 QuickSpecs for Technical Specifications
such as height, width, depth, weight, and color:
http://h18000.www1.hp.com/products/quickspecs/12402_div/12402_div.HTML
(Worldwide)
NOTE: For additional information regarding Rack Cabinets, please see the
following URL: http://www.hp.com/go/rackandpower.
HP Rack 10000 Series 10642 (42U) Infrastructure Rack (Low Voltage)
(Graphite Metallic)
10642 (42U) Infrastructure Rack (High Voltage)
HP Rack S10614 (14U) Rack Cabinet – Shock Pallet
HP Rack 10842 (42U, 800mm wide) – Pallet
HP Rack 10842 (42U, 800mm wide) – Shock Pallet
HP Rack 10647 (47U) – Pallet
HP Rack 10647 (47U) – Crated
HP Rack 10622 (22U) – Pallet
HP Rack 10622 (22U) – Shock Pallet
HP Rack 10622 (22U) – Crated
NOTE: xxxxxx-B21 (pallet) used to ship empty racks shipped on a truck.
xxxxxx-B22 (shock pallet) used to ship racks with equipment installed (by
custom systems, VARs and Channels). xxxxxx-B23 (crated) used for air
shipments of empty racks.
NOTE: It is mandatory to use a shock pallet in order to ship racks with
equipment installed. Not all HP equipment is qualified to be shipped in the Rack
10000 series
NOTE: Please see the Rack 10000 QuickSpecs for Technical Specifications
such as height, width, depth, weight, and color:
http://h18000.www1.hp.com/products/quickspecs/10995_div/10995_div.HTML
(Worldwide)
NOTE: For additional information regarding Rack Cabinets, please see the
following URL: http://www.hp.com/go/rackandpower
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
358254-B21
AF001A
AF002A
AF003A
AF004A
AF011A
AF012A
AF013A
AF014A
379006-001
379005-001
292302-B22
257415-B21
257415-B22
245160-B21
245160-B23
245163-B21
245163-B22
245163-B23
Page 30
QuickSpecs
HP ProLiant DL360 Generation 5
Options
Keyboards and
Monitors
TFT7210R Rack Mounted 17" Monitor
TFT7600 Rackmount Keyboard Monitor US
TFT7600 Rackmount Keyboard Monitor UK
TFT7600 Rackmount Keyboard Monitor GR
TFT7600 Rackmount Keyboard Monitor FR
TFT7600 Rackmount Keyboard Monitor IT
TFT7600 Rackmount Keyboard Monitor SP
TFT7600 Rackmount Keyboard Monitor DEN
TFT7600 Rackmount Keyboard Monitor NOR
TFT7600 Rackmount Keyboard Monitor SE/FI
TFT7600 Rackmount Keyboard Monitor SWI
TFT7600 Rackmount Keyboard Monitor PORT
TFT7600 Rackmount Keyboard Monitor BEL
TFT7600 Rackmount Keyboard Monitor JPN2
TFT7600 Rackmount Keyboard Monitor RUS
TFT7600 Rackmount Keyboard Monitor INTL
348373-B21
AG052A
AG053A
AG054A
AG055A
AG056A
AG057A
AG058A
AG059A
AG060A
AG061A
AG062A
AG063A
AG064A
AG065A
AG066A
1U Rackmount Keyboard with USB, US
1U Rackmount Keyboard with USB, UK
1U Rackmount Keyboard with USB, GR
1U Rackmount Keyboard with USB, FR
1U Rackmount Keyboard with USB, ITL
1U Rackmount Keyboard with USB, SP
1U Rackmount Keyboard with USB, DEN
1U Rackmount Keyboard with USB, NOR
1U Rackmount Keyboard with USB, SE/FI
1U Rackmount Keyboard with USB, SWI
1U Rackmount Keyboard with USB, PORT
1U Rackmount Keyboard with USB, BEL
1U Rackmount Keyboard with USB, JPN2
1U Rackmount Keyboard with USB, RUS
1U Rackmount Keyboard with USB, INTL
NOTE: For additional information regarding Rack Cabinets, please see the
following URL: http://www.hp.com/go/rackandpower.
AG072A
AG073A
AG074A
AG075A
AG076A
AG077A
AG078A
AG079A
AG080A
AG081A
AG082A
AG083A
AG084A
AG085A
AG086A
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
Page 31
QuickSpecs
HP ProLiant DL360 Generation 5
Options
HP KVM Switch
Options
HP Serial Console
Server Options
2x1x16 IP Console Switch with Virtual Media
4x1x16 IP Console Switch with Virtual Media
2x16 Server Console Switch with Virtual Media
PS/2 Virtual Media Interface Adapter, 1 pack
NOTE: Requires PS/2 and one USB port on server.
Server Console Switch (KVM), 0 x 1 x 8 port
Server Console Switch (KVM), 0 x 2 x 16 port
PS/2 Interface Adapter, 1 pack
PS/2 Interface Adapter, 8 pack
USB Interface Adapter, 1 pack
Serial Interface adapter - 1 Pack with power supply
NOTE: Cat5e cables are required to connect Interface Adapters to Console
Switches. Cat5e cables can be found at the following URL:
http://www.hp.com/go/kvm.
HP 1x 4 USB/PS2 KVM Switch, TT (NA/JPN)
HP 1x 4 USB/PS2 KVM Switch, TT (AU/NZ)
HP 1x 4 USB/PS2 KVM Switch, TT (UK)
AF601A
AF602A
AF600A
AF604A
336044-B21
336045-B21
262588-B21
262587-B21
336047-B21
373035-B21
371301-D71
371301-011
371301-031
HP 1x 4 USB/PS2 KVM Switch, TT (EU)
HP 1x 4 USB/PS2 KVM Switch, RM (ALL)
HP PS2 KVM Cable with audio, 6', 2-pack
HP USB KVM Cable with audio, 6', 2-pack
NOTE: For additional information regarding KVM switches, Serial Console
servers, rack mount monitors, keyboards and all related options please see the
following URL: http://www.hp.com/go/kvm.
371301-A21
371302-B21
371730-B21
371729-B21
HP 16 Port Serial Console Server (worldwide)
HP 48 Port Serial Console Server (worldwide)
Serial Adapter, RJ45-DB9 DCE Female, 1 Pack
Serial Adapter, RJ45-DB9 DCE Female, 8 Pack
NOTE: Cat5e cables are required to connect Serial Adapters to Serial Console
Servers. Additional Serial Adapters and Cat5e cables can be found at the
following URL: http://www.hp.com/go/kvm.
NOTE: For additional information regarding KVM switches, Serial Console
servers, rack mount monitors, keyboards and all related options please see the
following URL: http://www.hp.com/go/kvm.
AF101A
AF102A
AF103A
AF110A
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
Page 32
QuickSpecs
HP ProLiant DL360 Generation 5
Options
Service and Support
Offerings (HP Care
Pack Services)
Hardware Services 4-Hour On-site Service
4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic
4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic
Hardware Services 6-Hour Call to Repair On-site Service
6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years,
Electronic
Hardware Services Next Business Day On-Site Service
Hardware Installation, Electronic
Installation & Start-Up of a ProLiant server and Microsoft or Linux O/S per the
Customer Description and/or Data Sheet. To be delivered on a scheduled basis
8am-5pm, M-F, excl. HP holidays, Electronic
Support Plus
Onsite HW support, 8am-9pm, M-F, 4hr response and Microsoft O/S SW Tech
support offsite, onsite at HP's discretion, 8am-9pm, M-F 2hr response time excl.
HP holidays, Electronic
Support Plus 24
Onsite HW support 24x7, 4hr response and Microsoft O/S SW Tech support
offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays,
Electronic
Onsite HW support 24x7, 4hr response and SuSE Linux SW Tech support
offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays,
Electronic
Onsite HW support 24x7, 4hr response and Red Hat ES Linux SW Tech support
offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays,
Electronic
NOTE: For more information, customer/resellers can contact
http://www.hp.com/services/carepack.
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
U4496E
U4497E
U4498E
U4506E
U4507E
U4508E
U4509E
U6310E
U8332E
Page 33
QuickSpecs
HP ProLiant DL360 Generation 5
Memory
NOTE: Memory configurations listed do not apply to "Factory Integrated Models".
NOTE: Memory DIMMs in systems with the Front Side Bus (FSB) running at 1333 MHz will run at 667 MHz and in systems
with a FSB running at 1066 MHz or 667 MHz the memory DIMMs will run at 533 MHz.
HP ProLiant DL360 G5 Entry and Base Models
Standard Memory
1 GB PC2-5300 Fully Buffered DIMMs (DDR2-667) installed (2 x 512 MB)
Upgrading Memory and Memory Interleaving
When upgrading memory, DIMMs 1A and 2A must match. DIMMs 3B and 4B, DIMMs 5C and 6C, and DIMMs 7D and 8D
must match and must be installed as a pair. When DIMMs 1A and 2A are populated the system is automatically configured
for 2:1 interleaving. When all 4 banks are populated the system is automatically configured for 4:1 interleaving. When four,
six, or eight DIMMs are populated with identical DIMMs the system is automatically configured for bank interleaving.
Standard Memory Plus Optional Memory
Up to 25 GB memory is available with the standard memory of 1 GB and the optional installation of PC2-5300 Fully Buffered
DIMMs (DDR2-667) memory kits.
Standard Memory Replaced with Optional Memory
Up to 32 GB of memory is available with the removal of the standard 512 MB of memory and the optional installation of PC25300 Fully Buffered DIMMs (DDR2-667) memory kits.
NOTE: 4 GB Fully Buffered DIMMs kits will be available shortly following server availability to allow a maximum of 32 GB.
Today's maximum is 16 GB utilizing 2 GB DIMMs.
NOTE: Chart does not represent all possible configurations.
Memory
Slot
1
2
3
4
5
6
7
8
Standard
1 GB
512 MB
512 MB
Empty
Empty
Empty
Empty
Empty
Empty
Optional
25 GB
512 MB
512 MB
4 GB
4 GB
4 GB
4 GB
4 GB
4 GB
Maximum
32 GB
4 GB
4 GB
4 GB
4 GB
4 GB
4 GB
4 GB
4 GB
NOTE: In the online spare configuration, the ROM automatically configures the last populated bank as the spare memory. If
only banks A and B are populated, bank B is the spare bank. If banks A, B, and C are populated, bank C is the spare bank, If
banks A, B, C and D are populated, bank D is the spare bank, Online spare memory is configured through RBSU.
NOTE: Mirrored Memory uses mirrored banks to provide a high level of memory redundancy. Customer chooses to
implement or not: User selectable via BIOS and default is off.
Following are memory options available from HP:
1 GB FBD PC2-5300 2 x 512 MB Kit
2 GB FBD PC2-5300 2 x 1 GB Kit
4 GB FBD PC2-5300 2 x 2 GB Kit
8 GB FBD PC2-5300 2 x 4 GB Kit
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
397409-B21
397411-B21
397413-B21
397415-B21
Page 34
QuickSpecs
HP ProLiant DL360 Generation 5
Memory
HP ProLiant DL360 G5 Performance Models
Standard Memory
2 GB PC2-5300 Fully Buffered DIMMs (DDR2-667) (2 x 1 GB)
Upgrading Memory and Memory Interleaving
When upgrading memory, DIMMs 1A and 2A must match. DIMMs 3B and 4B, DIMMs 5C and 6C, and DIMMs 7D and 8D
must match and must be installed as a pair. When DIMMs 1A and 2A are populated the system is automatically configured
for 2:1 interleaving. When all 4 banks are populated the system is automatically configured for 4:1 interleaving. When four,
six, or eight DIMMs are populated with identical DIMMs the system is automatically configured for bank interleaving.
Standard Memory Plus Optional Memory
Up to 14 GB memory is available with the standard memory of 2 GB and the optional installation PC2-5300 Fully Buffered
DIMMs (DDR2-667) memory kits.
Standard Memory Replaced with Optional Memory
Up to 32 GB of memory is available with the removal of the standard 1 GB of memory and the optional installation of PC25300 Fully Buffered DIMMs (DDR2-667) memory kits.
NOTE: Chart does not represent all possible configurations.
Memory
Slot
1
2
3
4
5
6
7
8
Standard
2 GB
1 GB
1 GB
Empty
Empty
Empty
Empty
Empty
Empty
Optional
14 GB
1 GB
1 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
Maximum
32 GB
4 GB
4 GB
4 GB
4 GB
4 GB
4 GB
4 GB
4 GB
NOTE: In the online spare configuration, the ROM automatically configures the last populated bank as the spare memory. If
only banks A and B are populated, bank B is the spare bank. If banks A, B, and C are populated, bank C is the spare bank,
Online spare memory is configured through RBSU.
NOTE: Mirrored Memory uses mirrored banks to provide a high level of memory redundancy. Customer chooses to
implement or not: User selectable via BIOS and default is off.
Following are memory options available from HP:
1 GB FBD PC2-5300 2 x 512 MB Kit
2 GB FBD PC2-5300 2 x 1 GB Kit
4 GB FBD PC2-5300 2 x 2 GB Kit
8 GB FBD PC2-5300 2 x 4 GB Kit
397409-B21
397411-B21
397413-B21
397415-B21
Online spare FBDIMM configuration requirements (in addition to general configuration requirements):
When only bank A is being used, it must be fully populated with dual-rank FBDIMMs.
If banks A and C are being used, they must be fully populated.
If installed, bank A and bank C must contain FBDIMMs with identical part numbers.
If installed, bank B and bank D must also contain FBDIMMs with identical part numbers.
In online spare mode, FBDIMMs must be populated as specified in the following table:
Configuration
Branch 0
Branch 0
Branch 1
Bank A
Bank C
Bank B
1A and 3A
2C and 4C
5B and 7B
1*
X
2
X
X
3
X
X
X
*NOTE: Configuration 1 is only supported if using bank A, populated with dual-rank FBDIMMs.
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
Branch 1
Bank D
6D and 8D
X
Page 35
QuickSpecs
HP ProLiant DL360 Generation 5
Memory
Mirrored memory FBDIMMs configuration requirements (in addition to general configuration requirements):
Banks A and B must be fully populated.
Bank A and bank B must contain FBDIMMs with identical part numbers. If installed, bank C and bank D must also
contain FBDIMMs with identical part numbers.
When using mirrored memory mode, FBDIMMs must be populated as specified in the following table:
Configuration
1
2
Bank A
1A and 3A
X
X
Bank B
5B and 7B
X
X
Bank C
2C and 4C
X
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
Bank D
6D and 8D
X
Page 36
QuickSpecs
HP ProLiant DL360 Generation 5
Storage
1-6
6 x SFF SAS Hot Pluggable Hard Drive
Bays
A
Slimline Bay: Optional optical or floppy
drive
Drive Support
Quantity
Supported
Removable Media
Slimline 1.44-MB
Diskette Drive
Slimline 24x IDE CDROM Drive
Slimline DVD-ROM Drive
(8x/24x) Option Kit
(Servers)
Slimline DVD/CD-RW
Combo Option Kit
Slimline DVD-RW Drive
(8X) Option Kit
Position
Supported Controller
Up to 1
A
Integrated
Up to 1
A
Integrated IDE
Up to 1
A
Integrated IDE
Up to 1
A
Integrated IDE
Up to 1
A
Integrated IDE
Hard Drives
SAS Hard Drive
Quantity
Supported
6
Position
Supported Controller
146GB 3G SAS 10K SP
1-6
HP Smart Array E200i/64MB Controller
72GB 3G SAS 10K SP
HP Smart Array P400i/512MB BBWC Controller
72GB 3G SAS 15K SP
HP Smart Array P400i/256MB Controller
36GB 3G SAS 10K SP
HP Smart Array P600/256 BBWC Controller
36GB 3G SAS 15K SP
HP Smart Array P800/512 BBWC Controller
Please see NOTES below regarding hard drive quantity
supported by Smart Array Controller.
NOTE: The Smart Array E200i Controller can support a maximum of 4 hard drives.
NOTE: The Smart Array P400i Controller can support a maximum of 6 hard drives. To support drives 5 and 6, the optional
HP Mini SAS 4i 13.4 inch/0.35 m cable is required (PN 399546-B21).
NOTE: The Smart Array P600 Controller requires HP SAS 4i to Mini SAS 4i 31 inch/.79 meter cable (PN 411100-B21).
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
Page 37
QuickSpecs
HP ProLiant DL360 Generation 5
Storage
Serial-ATA (SATA) Hard Drive
Quantity
Supported
60GB 1.5G SATA 5.4K
6
Position
Supported Controller
1-6
HP Smart Array E200i/64MB Controller
HP Smart Array P400i/512MB BBWC Controller
HP Smart Array P400i/256MB Controller
HP Smart Array P600/256 BBWC Controller
HP Smart Array P800/512 BBWC Controller
Please see NOTES below regarding hard drive quantity
supported by Smart Array Controller.
NOTE: The Smart Array E200i Controller can support a maximum of 4 hard drives.
NOTE: The Smart Array P400i Controller can support a maximum of 6 hard drives. To support drives 5 and 6, the optional
HP Mini SAS 4i 13.4 inch/0.35 m cable is required (PN 399546-B21).
NOTE: The Smart Array P600 Controller requires HP SAS 4i to Mini SAS 4i 31 inch/.79 meter cable (PN 411100-B21).
External Storage
Quantity
Supported
Position
Supported Host Controller or Adapter
Modular Smart Array 20 Please see the
Family
Modular Smart
Array 20
QuickSpecs to
determine
configuration
requirements
Modular Smart Array 30 Please see the
Family
Modular Smart
Array 30
QuickSpecs to
determine
configuration
requirements.
Modular Smart Array 50
2
Enclosure
Modular Smart Array
1
500 G2 System
External
Smart Array 6402/128 Controller
Smart Array 6404/256 Controller
Smart Array 642 Controller
External
Smart Array 6402/128 Controller
Smart Array 6404/256 Controller
Smart Array 642 Controller
External
HP Smart Array P600/256 BBWC Controller
External
Modular Smart Array
1500 cs
External
Smart Array 642 Controller (used as Host Bus Adapter)
Please see the Modular Smart Array 500 G2 QuickSpecs for the
latest list of supported HBAs: http://www.hp.com/go/msa500
Please see the Modular Smart Array 1500 cs QuickSpecs (URL
below) for the latest list of supported HBAs
Modular Smart Array
1000
Please see the
Modular Smart
Array 1500 cs
QuickSpecs
below to
determine
configuration
requirements
Please see the
Modular Smart
Array 1000
QuickSpecs
below to
determine
configuration
requirements
External
Please see the Modular Smart Array 1000 QuickSpecs (URL
below) for the latest list of supported HBAs
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
Page 38
QuickSpecs
HP ProLiant DL360 Generation 5
Storage
Modular Smart Array 1000:
http://h18000.www1.hp.com/products/quickspecs/11033_div/11033_div.HTML (Worldwide)
Modular Smart Array 1500 cs: http://www.hp.com/go/MSA1500cs
Tape Drives, Tape Autoloaders, & Tape Libraries
NOTE: For an up-to-date listing of the latest O/S Support details for each of the Tape Drives listed below, please see the
following:
http://h18000.www1.hp.com/products/quickspecs/Division/10233.html (Worldwide)
NOTE: For an up-to-date listing of the latest O/S Support details for each of the Tape Autoloaders and Tape Libraries listed
below, please see the following:
http://h18000.www1.hp.com/products/quickspecs/Division/10809.html (Worldwide)
NOTE: SAS Tape Drives: Connecting hard drive cage and SAS tape to the same SAS Controller using split cable (supplied
with tape drive) deactivates 1 of the hard drive bays. Actual hard drive bay deactivated depends on where split cable plugs
into SAS drive connector. Example: 3x SAS cable connector plugged into SAS drive connector (5-8) on the back of the hard
drive cage would mean drive bay 8 is deactivated.
NOTE: For complete listing of tape drive offerings see
http://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html
For recommended tape drive offerings for this ProLiant server see the following:
Position
Controller
Supported
Controller Part
Number
HP StorageWorks
Tape Drives, External
Ultrium 232
Ultrium 448
Ultrium 460
Ultrium 960
Ultrium 920
DAT 40
DAT 72
DLT VS160
SDLT 600
External
HP SC11Xe Host Bus Adapter
HP StorageWorks
Tape Drives, External
DAT 24 USB
DAT 40 USB
DAT 72 USB
External
USB 2.0 Port
HP StorageWorks
Tape Drives, SAS
External
Ultrium 448 SAS
Ultrium 920 SAS
External
HP 8 Internal Port SAS HBA with RAID 0/1
347786-B21
HP Smart Array P400/256MB Controller
405132-B21
HP Smart Array P400/512MB BBWC Controller
411064-B21
NOTE: Please visit http://www.hp.com/go/connect for details about minimum
SAS controller firmware version and SAS cabling requirements.
HP StorageWorks
Autoloaders, External
DAT 72x10 Autoloader
1/8 Tape Autoloader
External
HP SC11Xe Host Bus Adapter
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
412911-B21
N/A
412911-B21
Page 39
QuickSpecs
HP ProLiant DL360 Generation 5
Storage
HP StorageWorks
SCSI Rack-Mount
Tape Drive
Enclosures
1U Rack-Mount Kit
3U Rack-Mount Kit
External
HP SC11Xe Host Bus Adapter
HP StorageWorks
USB Rack-Mount
Tape Drive
Enclosures
1U Rack-Mount Kit
External
USB 2.0 Port
HP StorageWorks
SAS Rack-Mount
Tape Drive
Enclosures
1U Rack-Mount Kit
External
HP 8 Internal Port SAS HBA with RAID 0/1
347786-B21
HP Smart Array P400/256MB Controller
405132-B21
HP Smart Array P400/512MB BBWC Controller
411064-B21
NOTE: Please visit http://www.hp.com/go/connect for details about minimum
SAS controller firmware version and SAS cabling requirements.
HP StorageWorks
Tape Libraries,
External
MSL2024 (Ultrium 448,
Ultrium 920 and 960based)
MSL4048 (Ultrium 448,
Ultrium 920 and 960based)
MSL6000 (Ultrium 960
and 460-based)
MSL6000 (SDLT 600based)
External
Please consult the EBS connectivity matrix at
http://www.hp.com/go/ebs for detailed connectivity information.
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
412911-B21
N/A
N/A
Page 40
QuickSpecs
HP ProLiant DL360 Generation 5
Power Specifications
To review typical system power ratings use the Active Answers Power Calculator which is available via the online tool
located at URL: http://h30099.www3.hp.com/configurator/calc/Power%20Calculator%20Catalog.xls
To drill down to calculators:
- Click on: "ProLiant Servers"
- Click on the Server of interest. Example: DL360 G5
- Click on: "Power Calculator" link. (You may need to scroll down to see it)
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
Page 41
QuickSpecs
HP ProLiant DL360 Generation 5
Technical Specifications
System Unit
Dimensions (H x W x D) 1.70 x 16.78 x 27.75 in (4.32 x 42.62 x 70.49 cm)
Weight
Maximum (six hard
37 lb (16.78 kg)
drives installed, two
power supply, two
processor)
No hard drives installed, 27.5 lb (12.47 kg)
one power supply, one
processor
Input Requirements
Rated Input Voltage
100 to 240 VAC
Rated Input Current
7.1 Amps (at 120VAC) to 3.5 Amps (240 at
VAC)
Rated Input Frequency 50 to 60 Hz
Rated Input Power
852 W
BTU Rating
2910 BTU/HR (at 120 VAC); 2870 (at 240 VAC)
NOTE: The BTU rating listed is for the Rated Input Power of 852 W.
Power Specifications To review typical system power ratings use the Power Calculator which
is available via the online tool located at URL:
http://h30099.www3.hp.com/configurator/calc
/Power%20Calculator%20Catalog.xls
Power Supply Output
Power
(per power supply)
Temperature Range
To drill down to calculators:
- Click on: "ProLiant Servers"
- Click on the Server of interest. Example: DL360 G5
- Click on: "Power Calculator" link. (You may need to scroll down to see
it)
Rated Steady-State
700 W
Power
Operating
Storage
Relative Humidity
(non-condensing)
Operating
Storage
Maximum Wet Bulb
Temperature
Acoustic Noise
50° to 95°F (10° to 35°C) at sea level with an
altitude derating of 1.0°C per every 1000 ft
(300 m) above sea level to a maximum of
10,000 ft (3000 m), no direct sustained
sunlight. Maximum rate of change is 10°C/Hr.
-40° to 158°F (-40° to 70°C) – Maximum rate
of change is 20°C/Hr.
10 to 90% relative humidity (Rh), 82.4°F
(28°C) maximum wet bulb temperature
5 to 95% relative humidity (Rh), based upon a
maximum temperature of 113° F (45° C).
Altitude maximum for storage corresponds to
a pressure minimum of 70 KPa.
82.4°F (28°C)
Listed are the declared A-Weighted sound power levels (LWAd) and
declared average bystander position A-Weighted sound pressure levels
(LpAm) when the product is operating in a 73.4°F (23°C) ambient
environment. Noise emissions were measured in accordance with ISO
7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA
109).
Idle:
L WAd (BELS)
6.6
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
Page 42
QuickSpecs
HP ProLiant DL360 Generation 5
Technical Specifications
L pAm (dBA)
Operating:
L WAd (BELS)
L pAm (dBA)
Smart Array E200i
Controller
Disk Drive and
Enclosure Interface
Smart Array P400i
Controller
Disk Drive and
Enclosure Interface
50
6.9 BELS
53 dBA
3G SAS (Serial Attached SCSI)
1.5G SATA (Serial Advanced Technology Attachment)
SAS Connectors
2 internal (SFF8484) x4 wide port connectors
Cache Memory Speed DDR-1/266 MHz provides up to 4.2 GB/s maximum bandwidth.
Server Interface
x4 2.5G PCIe provides 2GB/s maximum bandwidth.
SAS Speed
x8 3G SAS provides 2.4GB/s maximum bandwidth.
Cache Memory
40-bit 64MB or 128MB cache: ECC protection, battery-backed, and
transportable
Logical Volumes
Up to 32 logical volumes
Supported
Maximum Volume
3TB (6 x 500GB)
Capacity
Host Memory
64-bit, supporting greater than 4GB server memory space
Addressing
RAID Support
RAID 5 (Distributed Data Guarding) requires 128MB BBWC option
RAID 1, 1+0 (Striping & Mirroring)
RAID 0 (Striping)
Upgradeable Firmware Upgradeable Firmware
3G SAS (Serial Attached SCSI)
1.5G SATA (Serial Advanced Technology Attachment)
SAS Connectors
2 internal (SFF8484) x4 wide port connectors
Cache Memory Speed DDR2-533MHz with 40 or 72-bit wide bus provides up to 4.2 GB/s
maximum bandwidth.
Server Interface
x8 2.5G PCIe provides 2GB/s maximum bandwidth.
SAS Speed
x8 3G SAS provides 2.4GB/s maximum bandwidth.
Cache Memory
40-bit 256MB cache (72-bit 512MB module upgrades available); ECC
protection, battery-backed, and transportable
Logical Drives
Up to 32 logical drives
Supported
Maximum Logical Drive3 TB (6 x 500GB)
Capacity
Host Memory
64-bit, supporting greater than 4GB server memory space
Addressing
RAID Support
RAID 6 with ADG (Advanced Data Guarding) requires Battery Backed
Write Cache Upgrade
RAID 5 (Distributed Data Guarding)
RAID 1+0 (Striping & Mirroring)
RAID 0 (Striping)
Upgradeable Firmware Upgradeable Firmware with recovery ROM feature
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
Page 43
QuickSpecs
HP ProLiant DL360 Generation 5
Technical Specifications
Embedded NC373i
Multifunction Gigabit
Server Adapters
Network Interface
Compatibility
10/100/1000-T
EEE 802.3 10Base-T
IEEE 802.3ab 1000Base-T
IEEE 802.3u 100Base-TX
Data Transfer Method PCI Express, four lanes (x4)
Network Transfer Rate 10Base-T (Half-Duplex) 10 Mb/s
10Base-T (Full-Duplex) 20 Mb/s
100Base-TX (Half100 Mb/s
Duplex)
100Base-TX (Full200 Mb/s
Duplex)
1000Base-TX (Half and 2000 Mb/s
Full-Duplex)
Connector
RJ-45
Cable Support
10Base-T
Categories 3, 4 or 5 UTP up to 328 ft (100 m)
10/100/1000 Base-TX
Category 5 UTP up to 328 ft (100 m)
© Copyright 2007 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice.
Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel
Corporation.
The only warranties for HP products and services are set forth in the express warranty statements accompanying such
products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for
technical or editorial errors or omissions contained herein.
For hard drives, 1 GB = 1 billion bytes. Actual formatted capacity is less.
DA - 12476 Worldwide QuickSpecs — Version 17 — 1/19/2007
Page 44
Download PDF