resi-linx ®
MODULATORS
Radio Frequency Range
CODE: RL-DM1000
DVB-T Single Input Digital IR Modulator
FEATURES
• LCD Display for adjustments
• Single Input Digital IR Modulator that
converts video and audio signals to digital
COFDM DVB-T Channel
• 2K/8K Carriers
• Adjustable VHF/UHF Output (6-69)
• Built-in IR control for connecƟon to Vcomm’s
Video Hub, IR targets and emiƩers to allow
remote TV locaƟons to have IR control of AV
equipment
• Adjustable AƩenuaƟon (85dB launch)
• Adjustable logic channel numbering (LCN)
• Programmable Channel & Network Names
• Includes 12V DC Switch Mode Power Supply
• ASI and Composite Input
• MPEG 2
RL-DM1000
Output Channels
6-69
Output Connector
F type
Video Input
CVBS / ASI
Audio Input
Stereo
Power requirement
12V DC 3 AMP
Output Level
85dBuV
Output Level Adjustment
20 dB typ.
Number of Modulators
1
resi-linx | Vcomm
Vcomm Pty Ltd
abn 99 091 281 524
www.resi-linx.com
Radio Frequency Range
RL-DM1000
DVB-T Single Input Digital IR Modulator
complete with 12V DC 3A Power Supply
www.resi-linx.com
DigiMOD INSTALLATION MANUAL
Connections
Face Plate
A
B
C
Face Plate
OK
B
Not Active
A LCD Display
IR Repeater
B IR LED
D
Remote Power Switch
C Scroll up / down
E
Screw Holes for Mounting brackets
D Enter Button (OK)
®
Video and Audio Input
C
D
IR
A
RL-DM1000
Connections
A
B
F
12V DC Power Input
G
Not Active
H
RF Output
I
Antenna Input
C
D
OFF ON (REMOTE) PWR
IR REPEATER
DC 12V
IN
Audio R
ASI IN
E
Hardware Connection
1. Connect the RCA cable from the video source (eg.
CABLE / PAY TV, DVD, VCR, CAMERA) to the yellow
RCA video ‘INPUT’ jack A (Video) on the rear of the
RL-DM1000 Modulator.
2. Connect the RCA cable from the audio source to the red/
white ‘INPUT’ audio jacks (AudioR, AudioL) A on the
rear of the RL-DM1000 Modulator. Use red and white
jacks for dual input, or either one for single input.
3. Connect the RF output H from the RL-DM1000
to the modulator input on the RF Distribution Module
Alternatively, connect the RF output H to an existing
distribution system or directly to a television set.
4. Slide the Remote Power switch D to ‘ON’ if connecting
the Modulator to a RL-RF380 Video Hub.
5. Connect IR emitters RL-IR700/800 to the outputs C
on the rear of the RL-DM1000 Modulator. Place the
other end within 25mm of the IR receiver on the AV
source (depending on environmental conditions).
6. Connect the supplied 12V DC Switch Mode power pack
to the power input F .
WARRANTY
Vcomm Pty Ltd states that the warrant that the customer can rely on is that
provided by the manufacturer. In the event of any warranty claim please
contact us and we will forward it to the manufacturer. The manufacturer will
then determine the extent of their liability. This expressly negates, to the
extent possible by Australian law, any warranty reliance on Vcomm Pty Ltd.
ANT IN
RF OUT
REMOTE SET UP
I
H
G
F
E
Technical Specifications
INPUT
Video Input
Video Input Level
Video Mode
Audio Input
Audio Input Level
Input Connectors
Input Impedance
OUTPUT
Frenquency Range
Output Level
Output Impedance
Channel Bandwidth
Output Level Adjustment
MER
Connector Type
MODULATION
Video Resolution
Video Compression
Audio Compression
LCN
Carrier
Guard Intervals
Code Rate
Constellations
GENERAL
Power Supply
Consumption
Languages
Dimensions
Weight
CVBS
0.7-1.4 V (pp)
PAL / NTSC
Stereo
0.4 - 4.8 V (pp)
Video (RCA) - Audio (RCA)
75
177.5 - 816.5 MHz
85 dBμV
75
6,7,8 MHz
15 dB typ.
30 dB typ.
“F” female
Ʊ
Audio L
Ʊ
Video
PAL 720x576 @ 25fps
MPEG2 MP@ML
MPEG1 Layer ll
Yes
2K/8K
1/4, 1/8, 1/16, 1/32
1/2, 2/3, 3/4, 5/6, 7/8
16 QAM / 64 QAM
12 VDC 3-AMP
1100 MA
English
300mm x 200mm x 47mm
1.660kg
Vcomm Pty Ltd
ABN: 99 091 281 524
N15275
Radio Frequency Range
RL-DM1000
DVB-T Single Input Digital IR Modulator
complete with 12V DC 3A Power Supply
www.resi-linx.com
DigiMOD WIRING DIAGRAM
RL-RF210
RL-RF210
1
2
3
4
AUX MOD RF IN
PWR LED
ANT IN
MOD RF IN
(PWR/IR PASS)
TV OUTPUTS
Output
GAIN
Input Output 1
RL-RF300
ON
OFF
INPUT
5
FM TRAP
7
IR LED
PATENTED
RL-RF380
Output 3
8
IR
Output 2
12V DC
®
6
N15275
digiMOD
IR REPEATER
OFF ON (REMOTE) PWR
DC 12V
IN
V deo
Audio L
Aud o R
ASI IN
ANT IN
RF OUT
REMOTE SET UP
RL-DM1000
12V DC 3A
AV SOURCE x 1
To AV Source
WARRANTY
Vcomm Pty Ltd states that the warrant that the customer can rely on is that
provided by the manufacturer. In the event of any warranty claim please
contact us and we will forward it to the manufacturer. The manufacturer will
then determine the extent of their liability. This expressly negates, to the
extent possible by Australian law, any warranty reliance on Vcomm Pty Ltd.
Vcomm Pty Ltd
ABN: 99 091 281 524
N15275
Radio Frequency Range
RL-DM1000
DVB-T Single Input Digital IR Modulator
complete with 12V DC 3A Power Supply
www.resi-linx.com
DigiMOD INSTALLATION MANUAL
Factory Setting / Default Configuration
Output Channel
21
Attenuation
0
Constellation
QAM64
FEC
3/4
Guard Interval
1/16
Channel Region
Australia
Network Name
RL-NETWORK
Channel Name
CHANNEL - 1
Video Input
CVBS
Video Standard
PAL
Operating Adjustments
For changes to any of the default settings, scroll
up/down and enter the menu settings.
Safety Precautions
•
Do not apply power to the DVB-T Quad Input Digital IR Modulator until all components have been installed and all wiring has
been properly terminated. Failure to do so may result in damage to the product and void manufacturer’s warranty
•
Do not attempt to terminate, change or un-install any wiring without first unplugging Power Adapter from the DVB-T Quad Input
Digital IR Modulator
•
Do not expose any component to moisture. Doing so can create electrical hazards or render the component unusable. Exposure
to moisture will also void the warranty on the system.
•
This modulator is powered with a voltage of 12 VDC. The power supply voltage must not exceed this, otherwise this modulator
could suffer irreparable damage and subsequent invalidation of the warranty.
Note:
- Do not replace the power supply with a voltage greater than 12 VDC.
- Do not connect the modulator to the power if the power cord is damaged.
- Do not plug the modulator into the mains supply until all cables have been connected correctly.
- Do not cut the cord.
•
Avoid placing the modulator next to central heating components and in areas of high humidity.
•
Do not cover any modulator elements that could obstruct the ventilation slots and cause overheating.
•
If the modulator has been kept in cold conditions for a long time, keep it in a warm room no less than 2 hours before plugging it
into the mains.
WARRANTY
Vcomm Pty Ltd states that the warrant that the customer can rely on is that
provided by the manufacturer. In the event of any warranty claim please
contact us and we will forward it to the manufacturer. The manufacturer will
hen determine the extent of their liability. This expressly negates, to the
extent possible by Australian law, any warranty reliance on Vcomm Pty Ltd.
Vcomm Pty Ltd
ABN: 99 091 281 524
N15275
resi-linx®
MODULATORS
CODE: RL-DM2000
Radio Frequency Range
DVB-T Dual Input Digital IR Modulator
FEATURES
• LCD Display for adjustments
• Dual Input Digital IR Modulator that converts
video and audio signals to digital COFDM
DVB-T Channel
• 2K/8K Carriers
• Adjustable VHF/UHF Output (6-69)
• Built-in IR control for connecƟon to Vcomm’s
Video Hub, IR targets and emiƩers to allow
remote TV locaƟons to have IR control of AV
equipment
• Adjustable AƩenuaƟon (85dB launch)
• Adjustable logic channel numbering (LCN)
• Programmable Channel & Network Names
• Includes 12V DC Switch Mode Power Supply
• ASI and Composite Input
• MPEG 2
• Muxes all 2 Channels into a 7 MHz Channel
RL-DM2000
Output Channels
6-69
Output Connector
F type
Video Input
CVBS / ASI
Audio Input
Stereo
Power requirement
12V DC 3 AMP
Output Level
85dBuV
Output Level Adjustment
20 dB typ.
Number of Modulators
2
resi-linx | Vcomm
Vcomm Pty Ltd
abn 99 091 281 524
www.resi-linx.com
Radio Frequency Range
RL-DM2000
DVB-T Dual Input Digital IR Modulator
complete with 12V DC 3A Power Supply
www.resi-linx.com
DigiMOD INSTALLATION MANUAL
Connections
Face Plate
A
C
B
Face Plate
D
A LCD Display
B IR LED
IR
C Scroll up / down
OK
D Enter Button (OK)
®
Connections
RL-DM2000
A
B
A
Video and Audio Inputs x 2
B
Not Active
C
IR Repeaters x 2
D
Remote Power Switch
E
Screw Holes for Mounting brackets
F
12V DC Power Input
G
Not Active
H
RF Output
I
Antenna Input
C
1
D
2
OFF ON (REMOTE) PWR
IR REPEATERS
Audio L
Audio R
Video
Audio L
Audio R
ASI IN
E
Hardware Connection
1. Connect the RCA cable from the video source (eg. CABLE
/ PAY TV, DVD, VCR, CAMERA) to the yellow RCA video
‘INPUT’ jack A (Video) on the rear of the RL-DM2000
Modulator.
2. Connect the RCA cable from the audio source to the red/
white ‘INPUT’ audio jacks (AudioR, AudioL) A on the rear
of the RL-DM2000 Modulator. Use red and white jacks for
dual input, or either one for single input.
3. Repeat steps 1-2 for connection of other sources to AV
Inputs IN2.
4. Connect the RF output H from the RL-DM2000 to the
modulator input on the RF Distribution Module RL-RF380.
Alternatively, connect the RF output H to an existing
distribution system or directly to a television set.
5. Slide the Remote Power switch D to ‘ON’ if connecting
the Modulator to a RL-RF380 Video Hub.
6. Connect IR emitters RL-IR700/800 to the outputs C on
the rear of the RL-DM2000 Modulator. Place the other end
within 25mm of the IR receiver on the AV source (depending
on environmental conditions).
7. Connect the supplied 12V DC Switch Mode power pack to
the power input F .
WARRANTY
Vcomm Pty Ltd states that the warrant that the customer can rely on is that
provided by the manufacturer. In the event of any warranty claim please
contact us and we will forward it to the manufacturer. The manufacturer will
then determine the extent of their liability. This expressly negates, to the
extent possible by Australian law, any warranty reliance on Vcomm Pty Ltd.
ANT IN
RF OUT
REMOTE SET UP
I
H
G
F
E
Technical Specifications
INPUT
Video Input
Video Input Level
Video Mode
Audio Input
Audio Input Level
Input Connectors
Input Impedance
OUTPUT
Frenquency Range
Output Level
Output Impedance
Channel Bandwidth
Output Level Adjustment
MER
Connector Type
MODULATION
Video Resolution
Video Compression
Audio Compression
LCN
Carrier
Guard Intervals
Code Rate
Constellations
GENERAL
Power Supply
Consumption
Languages
Dimensions
Weight
CVBS
0.7-1.4 V (pp)
PAL / NTSC
Stereo
0.4 - 4.8 V (pp)
Video (RCA) - Audio (RCA)
75
177.5 - 816.5 MHz
85 dBμV
75
6,7,8 MHz
15 dB typ.
30 dB typ.
“F” female
Ʊ
Video
DC 12V
2
1
IN2
Ʊ
N1
PAL 720x576 @ 25fps
MPEG2 MP@ML
MPEG1 Layer ll
Yes
2K/8K
1/4, 1/8, 1/16, 1/32
1/2, 2/3, 3/4, 5/6, 7/8
16 QAM / 64 QAM
12 VDC 3-AMP
1300 MA
English
300mm x 200mm x 47mm
1.720kg
Vcomm Pty Ltd
ABN: 99 091 281 524
N15275
Radio Frequency Range
RL-DM2000
DVB-T Dual Input Digital IR Modulator
complete with 12V DC 3A Power Supply
www.resi-linx.com
DigiMOD WIRING DIAGRAM
RL-RF210
RL-RF210
2
3
4
AUX MOD RF IN
PWR LED
1
ANT IN
MOD RF IN
(PWR/IR PASS)
TV OUTPUTS
Output
GAIN
Input Output 1
RL-RF300
ON
OFF
INPUT
5
6
®
7
IR LED
PATENTED
RL-RF380
Output 3
8
Output 2
12V DC
FM TRAP
IR
N15275
digiMOD
IR REPEATERS
2
1
OFF ON (REMOTE) PWR
DC 12V
IN1
V deo
Audio L
Audio R
2
1
IN2
Video
Audio L
Audio R
ASI IN
ANT IN
RF OUT
REMOTE SET UP
RL-DM2000
12V DC 3A
AV SOURCE x 2
To AV Sources
WARRANTY
Vcomm Pty Ltd states that the warrant that the customer can rely on is that
provided by the manufacturer. In the event of any warranty claim please
contact us and we will forward it to the manufacturer. The manufacturer will
then determine the extent of their liability. This expressly negates, to the
extent possible by Australian law, any warranty reliance on Vcomm Pty Ltd.
Vcomm Pty Ltd
ABN: 99 091 281 524
N15275
Radio Frequency Range
RL-DM2000
DVB-T Dual Input Digital IR Modulator
complete with 12V DC 3A Power Supply
www.resi-linx.com
DigiMOD INSTALLATION MANUAL
Factory Setting / Default Configuration
Output Channel
21
Attenuation
0
Constellation
QAM64
FEC
3/4
Guard Interval
1/16
Channel Region
Australia
Network Name
RL-NETWORK
Channel Name
CHANNEL - 1
Operating Adjustments
For changes to any of the default settings, scroll
up/down and enter the menu settings.
CHANNEL - 2
Video Input
CVBS
Video Standard
PAL
Safety Precautions
•
Do not apply power to the DVB-T Quad Input Digital IR Modulator until all components have been installed and all wiring has
been properly terminated. Failure to do so may result in damage to the product and void manufacturer’s warranty
•
Do not attempt to terminate, change or un-install any wiring without first unplugging Power Adapter from the DVB-T Quad Input
Digital IR Modulator
•
Do not expose any component to moisture. Doing so can create electrical hazards or render the component unusable. Exposure
to moisture will also void the warranty on the system.
•
This modulator is powered with a voltage of 12 VDC. The power supply voltage must not exceed this, otherwise this modulator
could suffer irreparable damage and subsequent invalidation of the warranty.
Note:
- Do not replace the power supply with a voltage greater than 12 VDC.
- Do not connect the modulator to the power if the power cord is damaged.
- Do not plug the modulator into the mains supply until all cables have been connected correctly.
- Do not cut the cord.
•
Avoid placing the modulator next to central heating components and in areas of high humidity.
•
Do not cover any modulator elements that could obstruct the ventilation slots and cause overheating.
•
If the modulator has been kept in cold conditions for a long time, keep it in a warm room no less than 2 hours before plugging it
into the mains.
WARRANTY
Vcomm Pty Ltd states that the warrant that the customer can rely on is that
provided by the manufacturer. In the event of any warranty claim please
contact us and we will forward it to the manufacturer. The manufacturer will
then determine the extent of their liability. This expressly negates, to the
extent possible by Australian law, any warranty reliance on Vcomm Pty Ltd.
Vcomm Pty Ltd
ABN: 99 091 281 524
N15275
resi-linx®
MODULATORS
CODE: RL-DM4000
Radio Frequency Range
DVB-T Quad Input Digital IR Modulator
FEATURES
• Quad Input Digital IR Modulator that converts
video and audio signals to digital COFDM
DVB-T Channel
• LCD Display for adjustments
• 2K/8K Carriers
• Adjustable VHF/UHF Output (6-69)
• Built-in IR control for connecƟon to Vcomm’s
Video Hub, IR targets and emiƩers to allow
remote TV locaƟons to have IR control of AV
equipment
• Adjustable AƩenuaƟon (85dB launch)
• Adjustable logic channel numbering (LCN)
• Programmable Channel & Network Names
• Includes 12V DC Switch Mode Power Supply
• ASI and Composite Input
• MPEG 2
• Muxes all 4 channels into a 7 MHz channel
RL-DM4000
Output Channels
6-69
Output Connector
F type
Video Input
CVBS / ASI
Audio Input
Stereo
Power requirement
12V DC 3 AMP
Output Level
85dBuV
Output Level Adjustment
20 dB typ.
Number of Inputs
4
resi-linx | Vcomm
Vcomm Pty Ltd
abn 99 091 281 524
www.resi-linx.com
Radio Frequency Range
RL-DM4000
DVB-T Quad Input Digital IR Modulator
complete with 12V DC 3A Power Supply
www.resi-linx.com
DigiMOD INSTALLATION MANUAL
Connections
Face Plate
C
Face Plate
D
A LCD Display
B LED IR Display
IR
C Scroll Up / Down
OK
D Enter Button (OK)
®
Connections
RL-DM4000
A
N3
B
Video
Audio L
Audio R
N1
3
Video
Audio L
Audio L
Audio R
Audio L
Screw Holes for Mounting brackets
F
12V DC Power Input
G
Not Active
H
RF Output
I
Antenna Input
2
D
3
4
OFF ON (REMOTE) PWR
IR REPEATERS
Audio R
ASI IN
E
Hardware Connection
1. Connect the RCA cable from the video source (eg. CABLE
/ PAY TV, DVD, VCR, CAMERA) to the yellow RCA video
‘INPUT’ jack A (Video) on the rear of the RL-DM4000
Modulator.
2. Connect the RCA cable from the audio source to the red/
white ‘INPUT’ audio jacks (AudioR, AudioL) A on the rear
of the RL-DM4000 Modulator. Use red and white jacks for
dual input, or either one for single input.
3. Repeat steps 1-2 for connection of other sources to AV
Inputs IN2 - IN4.
4. Connect the RF output H from the RL-DM4000 to the
modulator input on the RF Distribution Module RL-RF380.
Alternatively, connect the RF output H to an existing
distribution system or directly to a television set.
5. Slide the Remote Power switch D to ‘ON’ if connecting
the Modulator to a RL-RF380 Video Hub.
6. Connect IR emitters RL-IR700/800 to the outputs C on
the rear of the RL-DM4000 Modulator. Place the other end
within 25mm of the IR receiver on the AV source (depending
on environmental conditions).
7. Connect the supplied 12V DC Switch Mode power pack to
the power input F .
WARRANTY
Vcomm Pty Ltd states that the warrant hat the customer can rely on is that
provided by the manufacturer. In the event of any warranty claim please
contact us and we will forward it to the manufacturer. The manufacturer will
then determine he extent of their liability. This expressly negates, to the
extent possible by Australian law, any warranty reliance on Vcomm Pty Ltd.
DC 12V
2
1
Video
Remote Power Switch
E
4
Audio R
IN2
Video
IR Repeater Outputs x 4
D
C
1
IN4
Not Active
C
ANT IN
RF OUT
REMOTE SET UP
I
H
G
F
E
Technical Specifications
INPUT
Video Input
Video Input Level
Video Mode
Audio Input
Audio Input Level
Input Connectors
Input Impedance
OUTPUT
Frenquency Range
Output Level
Output Impedance
Channel Bandwidth
Output Level Adjustment
MER
Connector Type
MODULATION
Video Resolution
Video Compression
Audio Compression
LCN
Carrier
Guard Intervals
Code Rate
Constellations
GENERAL
Power Supply
Consumption
Languages
Dimensions
Weight
CVBS
0.7-1.4 V (pp)
PAL / NTSC
Stereo
0.4 - 4.8 V (pp)
Video (RCA) - Audio (RCA)
75
177.5 - 816.5 MHz
85 dBμV
75
6,7,8 MHz
15 dB typ.
30 dB typ.
“F” female
Ʊ
B
Video and Audio Inputs Source IN1-IN4
Ʊ
A
A
B
PAL 720x576 @ 25fps
MPEG2 MP@ML
MPEG1 Layer ll
Yes
2K/8K
1/4, 1/8, 1/16, 1/32
1/2, 2/3, 3/4, 5/6, 7/8
16 QAM / 64 QAM
12 VDC 3-AMP
1700 MA
English
300mm x 200mm x 47mm
1.860 kg
Vcomm Pty Ltd
ABN: 99 091 281 524
N15275
Radio Frequency Range
RL-DM4000
DVB-T Quad Input Digital IR Modulator
complete with 12V DC 3A Power Supply
www.resi-linx.com
DigiMOD WIRING DIAGRAM
RL-RF210
RL-RF210
2
3
4
AUX MOD RF IN
PWR LED
1
ANT IN
MOD RF IN
(PWR/IR PASS)
TV OUTPUTS
Output
GAIN
Input Output 1
RL-RF300
ON
OFF
INPUT
5
®
7
IR LED
PATENTED
RL-RF380
Output 3
8
Output 2
12V DC
FM TRAP
6
IR
N15275
digiMOD
IN3
IR REPEATERS
1
2
3
IN4
Video
Audio L
Aud o R
V deo
Audio L
3
4
1
2
4
OFF ON (REMOTE) PWR
Audio R
DC 12V
IN1
IN2
Video
Audio L
Aud o R
V deo
Audio L
Audio R
ASI N
ANT IN
RF OUT
REMOTE SET UP
RL-DM4000
12V DC 3A
AV SOURCE x 4
To AV Sources
WARRANTY
Vcomm Pty Ltd states that the warrant that the customer can rely on is that
provided by the manufacturer. In the event of any warranty claim please
contact us and we will forward it to the manufacturer. The manufacturer will
then determine the extent of their liability. This expressly negates, to the
extent possible by Australian law, any warranty reliance on Vcomm Pty Ltd.
Vcomm Pty Ltd
ABN: 99 091 281 524
N15275
Radio Frequency Range
RL-DM4000
DVB-T Quad Input Digital IR Modulator
complete with 12V DC 3A Power Supply
www.resi-linx.com
DigiMOD INSTALLATION MANUAL
Factory Setting / Default Configuration
Operating Adjustments
Output Channel
21
Attenuation
0
For changes to any of the default settings, scroll
up/down and enter the menu settings.
Constellation
QAM64
FEC
3/4
Guard Interval
1/16
Channel Region
Australia
Network Name
RL-NETWORK
Channel Name
CHANNEL - 1
CHANNEL - 2
CHANNEL - 3
CHANNEL - 4
Video Input
CVBS
Video Standard
PAL
Safety Precautions
•
Do not apply power to the DVB-T Quad Input Digital IR Modulator until all components have been installed and all wiring has
been properly terminated. Failure to do so may result in damage to the product and void manufacturer’s warranty
•
Do not attempt to terminate, change or un-install any wiring without first unplugging Power Adapter from the DVB-T Quad Input
Digital IR Modulator
•
Do not expose any component to moisture. Doing so can create electrical hazards or render the component unusable. Exposure
to moisture will also void the warranty on the system.
•
This modulator is powered with a voltage of 12 VDC. The power supply voltage must not exceed this, otherwise this modulator
could suffer irreparable damage and subsequent invalidation of the warranty.
Note:
- Do not replace the power supply with a voltage greater than 12 VDC.
- Do not connect the modulator to the power if the power cord is damaged.
- Do not plug the modulator into the mains supply until all cables have been connected correctly.
- Do not cut the cord.
•
Avoid placing the modulator next to central heating components and in areas of high humidity.
•
Do not cover any modulator elements that could obstruct the ventilation slots and cause overheating.
•
If the modulator has been kept in cold conditions for a long time, keep it in a warm room no less than 2 hours before plugging it
into the mains.
WARRANTY
Vcomm Pty Ltd states that the warrant that the customer can rely on is that
provided by the manufacturer. In the event of any warranty claim please
contact us and we will forward it to the manufacturer. The manufacturer will
then determine the extent of their liability. This expressly negates, to the
extent possible by Australian law, any warranty reliance on Vcomm Pty Ltd.
Vcomm Pty Ltd
ABN: 99 091 281 524
N15275
Download PDF
Similar pages