Premium Security Pack QUICK INSTALLATION GUIDE

Ref. 510764 V1
Premium Security Pack
QUICK INSTALLATION GUIDE
A - SAFETY INSTRUCTIONS
A1 - OPERATING PRECAUTIONS
The Thombox and the accessories provided are designed for indoor use only, apart from the
external siren.
• Install the Thombox somewhere that it can be connected to the Internet via a high-speed
wired connection (512 kbit per second minimum, modem or router with at least one
available Ethernet port).
• When drilling, ensure that you do not damage hidden pipes or electric cables.
• The electrical installation must meet current standards and should be performed by a
qualified person.
• Do not expose the Thombox or its accessories to direct sunlight.
• Do not install the Thombox in locations with high humidity and/or extreme temperatures, or
where there is a risk that the equipment may be exposed to dust.
• Do not install the Thombox in cold locations or locations subject to large temperature
fluctuations.
• Never obstruct the Thombox's ventilation holes.
• Never cover the device.
• Do not daisy-chain extension cords and/or multi-socket adapters.
• Do not install near acidic chemicals, ammonia or sources of toxic gasses.
• Do not install in explosive environments or near volatile or inflammable products.
• Never put objects containing water on top of the device.
• Make sure that the device and its power supply are well ventilated.
• Test the smoke detector once a week by pressing the TEST button.
• A smoke detector does not prevent fires.
• Prepare an evacuation plan for the building beforehand.
• Effective protection will probably require several smoke detectors.
• WARNING: the detector included in this kit does not detect heat, gas or flames.
• This product emits an audible signal when it detects smoke. It is therefore totally standalone. It also has a radio function which allows it to warn the Thombox provided.
• The battery module's USB port is designed only for inserting the 3G key supplied. We
strongly recommend against using it for any other purpose.
• The battery module is intended as a backup power supply for the Thombox and is designed
to provide access to the mobile network in the case of a power cut or network outage. To
retain an Internet connection, a data-type SIM card (not included) is required.
• The cameras must not be installed where the lens filter may be vulnerable to scratching and
dirt.
• The camera is not designed for outside installation and should not be installed in locations
that are subject to extremes of humidity or temperature.
• Do not expose the camera lens to direct sunlight or any reflected light source.
• Do not unscrew the camera lens completely.
• The installation and use of the camera must comply with local laws.
Screen size
• Minimum recommended resolution: 1024 x 768
Internet connection
• High speed (512 kbit/sec MINIMUM) via ADSL Ethernet
Internet browsers with the latest updates
• Mozilla Firefox
• Google Chrome
• Safari
Warning: Not all of the interface features are compatible with Internet Explorer. You will
therefore need to use one of the browsers listed above.
Tablet, touchscreen smartphone (operation)
• Internet connection: High speed via ADSL Ethernet or WiFi or via mobile network.
• Operating system: Android 2.3 or later; iOS 6.0 or later. The iPhone app is optimised for
iPhone 4S and is compatible with iPhone, iPod touch and iPad.
• For the best user experience, a 3G or higher connection is recommended when a mobile
network is being used.
B - PRODUCT DESCRIPTION
D4 - ACTIVATING YOUR THOMBOX
D - INSTALLATION
Open your Internet browser (Mozilla Firefox, Google Chrome or Safari) and visit www.
thomsonbox.eu
1
2
1
5
6
x2
2
x1
3
x1
7
x2
4
x2
8
x2
9
x2
x2
x1
1
Power supply/wired connection/update LED indicator. During normal operation, the LED shows a steady green light. If it is flashing green, a problem with the wired Internet connection has been detected.
2
Power supply/3G connection/update LED indicator. During normal operation, the LED is off. If it is flashing green, a connection to the mobile network is currently being established (requires a data SIM card - not included - to be inserted into the 3G key on the battery module). If the LED shows a steady green light, the 3G connection has been established and is operational.
4
3
2
1
Rear
1
10
Always unplug the product from the mains before carrying out any maintenance.
Never use abrasive or corrosive substances to clean the products.
Use a soft, dry cloth.
Never use an aerosol to spray the product as this may damage the internal workings.
Stop using the smoke detector once the battery is spent, which is approximately 10 years
in normal operation.
• To clean the smoke detector, remove it from its mounting bracket by turning it anti-clockwise
and clean it with the vacuum hose, vacuuming near the openings located around the edge
of the smoke detector.
• Once you have finished cleaning the smoke detector, perform a TEST using the button
located on the side of the detector.
x1
11
15
12
x1
x1
13
x2
14
x1
2
x1
Serial Number :
0101ED2890Z04JLM55
16
x2
23
x2
1
17
x2
24
x2
2
18
x2
19
x8
20
x8
21
x1
22
x2
25
x1
Quick
setup
guide
1
Screw recess for wall mounting using screws
2
Hooks for fixing to a consumer unit DIN rail
Language selection
2
Create a new account
3
Log in to an existing account
4
Area to enter username/password
To activate your Thombox, click on 'REGISTER' and follow the on-screen instructions to create
your online account.
Top
26
x1
3
1Thombox
2
ARW-compatible antenna
Disposing of used batteries in the household waste is strictly forbidden. Batteries/
accumulators containing harmful substances are marked with symbols (shown
opposite) which indicate that it is forbidden to discard them in the household
waste. The corresponding heavy metal designations are as follows: Cd = cadmium,
Hg = mercury, Pb = lead. You can dispose of these batteries/accumulators at
local recycling amenities (centres for sorting recyclable materials) which are required to accept
them. Keep batteries/button cells/accumulators out of reach of children and store them in a
safe place not accessible to them as they could be swallowed by children or domestic animals.
May be fatal if swallowed.
In the event that a battery is swallowed, consult a doctor or go to A&E immediately. Never
short-circuit the batteries, and do not burn or recharge them as they may explode!
3
Mains adapter
4
Ethernet or RJ45 cable
5
Indoor motion detector (does not detect pets weighing < 25kg)
6
Wall bracket for motion detector
7
Ceiling bracket for motion detector
8
Joint for motion detector
9
Opening detector and magnet for doors or windows
10
Backup battery
11
3G key
This logo denotes that devices which are no longer in use must not be disposed of
as household waste as they are likely to contain hazardous substances which are
dangerous to both health and the environment. Return the equipment to your local
distributor or use the recycling collection service provided by your local council.
12
Alarm remote control
13
720p IP camera
14
Smoke detector
15
Indoor siren
16
Screws for wall or ceiling mounting for smoke detector
17
Wall plugs for wall or ceiling mounting for smoke detector
18
Screw for attaching the motion detector and indoor siren to the adjustable mount
19
Wall plugs for motion detector and indoor siren adjustable mount
20
Screws for motion detector and indoor siren adjustable mount
21
Screws for closing the opening detector cover
22
Screw for opening detector magnet
23
Screws for attaching the camera
23
Wall plugs for mounting the camera
24
CD containing camera software
25
Quick installation guide
Computer
Operating system:
• Microsoft® Windows XP (32-bit), Vista®, Windows 7, Windows 8 and later.
• Mac OS X v10.6, v10.7 (32-bit and 64-bit) and later.
IMPORTANT: No software or application is required to use the product with a computer.
To enable the above and be able to create scenes (action sequences) which will simplify your
day-to-day life, you need to register your Thombox (only when you first install it), and pair your
ARW technology compatible accessories with it.
The Thombox is completely modular and there is no limit to the number of accessories it can
control.
Front
•
•
•
•
•
A4 - MINIMUM CONFIGURATION REQUIREMENTS
The Thombox is a home automation unit which connects to your ADSL modem (Freebox,
Livebox, etc.) and enables you to manage your home security from any location as if you
were using the actual alarm control unit at home or remotely. The system also allows you to
control your comfort accessories (lighting, etc.), openers (shutter motors, garage doors, etc.)
and manage your energy use (heating and electricity consumption) with just a few clicks on
a computer, touchscreen tablet or smartphone, from anywhere in the world with an internet
connection.
D1 - THOMBOX
B1 - PACK CONTENTS
A2 - SERVICING AND CLEANING
A3 - RECYCLING
C - ABOUT THE THOMBOX CONNECTED HOME CONCEPT
1
4
2
1
12V DC 1.5A mains socket
2
RJ45 socket for connecting to the Ethernet network
3
Reset button
4
Antenna connector
The email address and password will allow you to access your account.
For more security, use a password which is difficult to guess with a combination of letters and
numbers.
During the registration process, you will be required to enter your Thombox serial number.
This number is located on the bottom of your Thombox and is made up of a combination of
16 letters and numbers:
D2 - ATTACHING THE ANTENNA
The antenna provided allows the Thombox to communicate with accessories compatible with
ARW technology. It must be in place for the Thombox to work. For optimal range, the antenna
must be positioned vertically.
Warning: The antenna should not be screwed in with excessive force to prevent damage to
the antenna connector.
Serial Number :
0101ED2890Z04JLM55
Note
After registration, check your inbox: a validation email is sent during the registration process
and must be confirmed before continuing.
D3 - CONNECTIONS
Connect the Ethernet cable (RJ45) between your ADSL box and your Thombox then connect
the mains. Your Thombox will start automatically. Once the LED becomes steady, the Internet
connection is established and you can begin to activate your Thombox (only required on first
installation).
E - OPERATION
Once you have created your account, sign in using your login and password to access your
Thombox and the accessories paired to it:
1
2
3
4
5
6
7
8
G - INTRODUCTION TO THE ACCESSORIES AND PAIRING THEM
WITH THE THOMBOX
Installation with or without adjustable mount
This detector detects the presence of a moving person in the room where it is installed, and
transmits the information to the central unit which sounds an alert.
ø4mm
wall
Choice of location
For effective protection, follow the following rules when choosing where to place your indoor
motion detector:
• Do not place the detector opposite a window or a source of reflected light.
• Do not place the detector opposite a source of hot or cold air (radiator, air vent, etc.).
• If you are using several detectors to cover the same room, ensure that the beams do not
cross.
• Place your detector at right angles to the through route (and not in the direction of the
through route)
1.80m
to 2.40m
A-The detector is facing a mirror (which reflects the sun's rays) and a fireplace. The through
route does not cross the beams at right angles.
B-The beams are crossing and one detector is opposite a window.
C-The door and the window are protected and the detector is installed so that the through
route crosses the beams at right angles.
D-The detector is installed so that the through route crosses the beams at right angles.
27mm
view in profile
10
correct
Thombox status. ONLINE when the Internet connection is operating normally, OFFLINE when there is an Internet connection problem.
2
'Synchroniser [Synchronise]' button: if needed, applies any changes to your Thombox you have made using the interface. This button flashes when changes require an update.
3
'Refresh' button: updates the screen contents and the data sent by your Thombox.
4
GENERAL: Allows you to access information about your account and adding accessories to your Thombox.
5
EVENEMENTS [EVENTS]: All information collected by your Thombox and any paired accessories is archived here.
6
'Déconnexion [log off]' button: quits the Thombox interface.
7
'Créateur de règles [rule creator] button: access the interface for creating programmes and actions based on the time of day or the date, an accessory being triggered, etc.
8
Language selection
9
Widgets de gestion [management widgets]: the overall condition of your system is displayed using graphical areas which you can resize, customise or hide however you like. In this section, you can view and control your equipment remotely and in real time.
floor
Corner mounting:
9
1
ø4mm
Installation without adjustable mount
Wall mounting:
G1 - MOVEMENT DETECTOR – Indoor – pet-compatible
incorrect
Wall mounting:
ø4mm
A
C
ON
1
F1 - ADDING ACCESSORIES
IMPORTANT:
Before permanently attaching your accessories, we advise you to test the range. To do so,
place your detectors as close as possible to the place you wish to install them before you
attach them and test your accessory.
For example, to test an opening detector, open a door or window and verify that the interface
recognises that it is open.
Each accessory within your setup must be paired to your Thombox to be able to operate. Click
on 'GENERAL [GENERAL]' from your Thombox interface, then on the 'Ajouter des modules
[Add modules]':
3
4
ø8mm
B
1.80m
to 2.40m
D
2.20m
floor
1m
Ceiling mounting:
10 Help button: each widget has a help feature which explains what it is for and how to use it.
F - CONFIGURATION
CTS
2
ø4mm
1m
7.5m
15m
Area accessible to animals below the weight threshold (15kg or 25kg, see settings
below)
Zone forbidden to animals (will trigger an alarm)
Note: the range and detection sensitivity can be configured: see the settings below
Operation
The sensor on the front can detect variations in infra-red rays: when a living being moves in
front of the sensor, the motion is detected.
• An animal moving along the ground will not cause motion to be detected, as long as its
weight does not surpass the weight specified in the settings (15kg or 25kg)
Installation with adjustable mount (included)
You can affix the motion detector to a bracket for wall or ceiling mounting using a ball-joint
mount in order to position the angle of detection.
Wall
mounting
Ceiling
mounting
37mm
OR
Settings
Different settings are available on the inside of the detector:
21
Your Thombox then sets itself to learning mode and begins a 60-second countdown.
Trigger the accessory to be added during this 60-second period.
Once the accessory has been recognised by the Thombox, 'Module ajouté [Module added]'
will be displayed and you will be asked to name the accessory.
(&(
• Switch 1: if it is lowered, this deactivates the LED on the front during a radio transmission to
be more discreet.
• Switch 2: if it is raised, detected movement triggers an alarm. If it is lowered, an alarm will
only be triggered if 3 detections take place consecutively, in order to avoid false detections.
• Switch 3: if it is raised, all radio transmissions are followed by a 2 minute pause to conserve
battery life.
• Switch 4: sets the size of pets which are not to be detected by the product. Switch up:
<15kg. Switch down: <25kg.
• Adjustment dial: adjusts the detection range. Turn clockwise to increase the distance, and
turn anti-clockwise to reduce the distance. The range can be set from around 30% to 100%
of the maximum range.
Follow these steps for every accessory you want to pair to the Thombox.
ON
1
CTS
2
3
4
ø8mm
Pairing with the Thombox
During the countdown, remove the tab which protects the detector battery (remove the tab
before installing the detector in its final location).
G3 - BACKUP BATTERY AND 3G KEY
The backup battery and 3G key will cut in if there is a power outage and/or failure of the
Thombox's internet access.
Launch the 'IP Camera Search Tool' included on the CD to locate the camera on your network
then double click on the corresponding entry.
The battery module is designed to be connected directly to the left hand side of the Thombox.
Remove the protective cover from the Thombox and insert the battery module into the socket
provided.
If the electricity or computer network is restored, the Thombox will switch back to mains and/
or wired network after a few moments.
-
The top indicator light on the battery module shows its state of charge:
Green: the Thombox is being powered by its mains adaptor.
Red: the Thombox is being powered by its backup battery.
Off: the battery module is disconnected or the battery is completely discharged.
- Blue: your battery is not fully charged but is currently charging.
- Flashing blue: battery problem / battery out of service
- Off: charging has been interrupted.
The bottom indicator light on the battery module shows its state of charge:
The 3G indicator light shows its state:
- Purple: initiating connection
- Flashing red: connection ready (slow flashing) or in use (rapid flashing)
G2 - OPENING DETECTOR FOR DOORS AND WINDOWS
When installed on a door or window, this device will detect any attempts at intrusion (detected
when the magnet is moved away) and transmits the information to a central unit which triggers
an alert.
Setup
Connect to your camera from your browser:
Your Thombox will also tell you what method is being used to connect to the internet:
- Top indicator light: the wired connection is being established (flashing) or has been
established (permanently lit)
- Middle indicator light: the wireless backup connection is being established (flashing) or has
been established (permanently lit).
2mm
66mm
22mm
G4 - ALARM REMOTE CONTROL
The remote control allows you to activate and deactivate your alarm system.
The buttons are typically assigned as follows:
In order to establish a backup connection to the mobile network, the product needs a data SIM
card for a smartphone, tablet or computer (not supplied).
Insert the card into the housing, making sure it is the right way up as shown below:
Arms your entire system,
for example when you
have left the property.
Disarms the whole
system.
Triggers your system in the
event of an emergency,
illness or other problem.
Arms part of your system,
when you are present
and want to arm your
protection overnight, for
example.
ø4mm
Replace the housing cover, then plug the key into the USB port on the battery module:
Select the language of your choice. The default username is "admin" and there is no pre-set
password.
The camera will immediately ask you to change the login username:
When you press a button on the remote control, the LED on the remote control tells you if your
Thombox has received the instruction:
• Red LED: indicates that a radio transmission is taking place.
• Orange LED: the Thombox has not received the command sent from your remote control.
If this happens, try again or move closer to your Thombox.
• Green LED: the Thombox has received the instruction that you sent.
Pairing with the Thombox
During the countdown, hold down the 2 buttons at the top of your remote control for at least
5 seconds.
Type your new username and the password of your choice.
Optional: setting up a wireless connection
Connect to your camera using the username and password you have just created.
Click on the Réglages [Settings] tab then on the 'Assistant de configuration [Configuration
wizard]' button to launch the wizard which allows you to set your camera up for WiFi:
Note: If you do not want to use the mobile network connection feature, the battery module
can be used without the key.
Pairing with the Thombox
You do not need to do anything to the backup battery as it starts charging as soon as it is
connected to the Thombox and will instantly cut in if there is a power failure.
To configure access to the mobile network, please login to your account at http://thomsonbox.
eu. From the "GENERAL" menu, go into "Paramètres généraux" (General settings) and select
the "Paramètres" (Settings) tab:
12mm
max
25mm
- Attach the magnet using double-sided
tape or the screws provided.
- Attach the magnet opposite the two
studs on the detector.
studs
G5 - 720p IP camera
Your camera allows you to take photos via the Thombox when movement is detected. Photos
are stored in the Thombox's 'Cameras' widget, and the live image from the camera is also
accessible from this same widget.
Pairing with the Thombox
During the countdown, remove the tab which protects the detector battery (remove the tab
before installing the detector in its final location). Wait for 10-20 seconds.
1
2
3
4
1
"SIM APN": enter the APN that corresponds to your SIM card
2
"SIM PIN": enter your SIM card PIN code if one has been provided
3
"SIM Password" : enter the corresponding password.
4
"SIM Nom d’utilisateur": if needed, enter the name of the user corresponding to your SIM card
Setup
The camera connects to your wired or wireless (WiFi) network. To set up the camera, a wired
connection is required (even if you will later decide to use a wireless connection).
Once you have finished, you can disconnect the network cable from your camera and close
the page.
camera
Mains adapter
Reset
WPS
Sync your Thombox using the button in the top strip to update it with the new configuration.
This data will be supplied along with your SIM card by your mobile phone operator. Entering a
user name and a password may be optional and depends on your mobile operator.
Modem/router connected to the
internet
Power
Wireless
Manual configuration
If you do not want to configure your Thombox automatically, here is the full list of commands
your Thombox will need to know for it to use your camera:
You can now install your camera:
1
2
G6 - SMOKE DETECTOR
•
•
•
•
For optimum protection, install a detector in each room.
For minimum protection install one detector per floor, preferably in corridors
and stairwells.
Switch on the smoke detector alarm (see TEST mode) in the place you
intend to install it and check that you can hear it in every bedroom with the door
shut and a radio on.
The volume of the radio should be set to a level corresponding to a relatively
loud conversation. If you cannot hear it due to the radio, it is highly likely
that your alarm would not be loud enough to wake someone who is asleep.
FLAT
3
4
&XLVLQH
kitchen
6pMRXU
stay
Make sure the camera is properly secured to prevent it from falling.
Once you have set up the device, you can adjust the focus of the image if it is lacking
sharpness. Gently rotate the lens to adjust the focus.
WARNING: Do not unscrew the lens completely or force it.
bedroom
&KDPEUH
bedroom
&KDPEUH
5
Pairing with the Thombox
Your camera is optimised for use with a Thombox. Go into the interface of your Thombox to
pair your camera and click on 'Ajouter une nouvelle caméra [Add new camera]' in the Cameras
widget:
6
In general, to avoid false alarms, smoke detectors should not be installed:
• In the garage (combustion residues are present when the car is started).
• In the kitchen (parasite smoke generated by hobs, oven, etc.).
• In front of heating installations or in front of a ceiling fan or other zones where
air circulates.
• In very humid areas or in bathrooms with a bath or
shower. The steam and humidity may cause false alarms.
• In dusty areas. Dust particles can trigger false alarms
or even stop the smoke detector from sounding an alarm.
bedroom
&KDPEUH
7
8
DETACHED HOUSE
tick the row
corresponding to
your camera
Tick the box on the row corresponding to your camera, then click Ajouter [Add].
If your camera has not been detected, enter the address of your camera as indicated by the
IP Camera Search Tool software:
1
Assign a suitable name to the camera
2
Address for connecting your camera to the interface, filled in automatically when you
add the camera (do not forget the ':88' at the end of the address)
3
Your camera's username (default = admin)
4
Your camera's password (default = none)
5
High quality stream: the address is:
rtsp://ip address of your camera:88/videoMain (no spaces)
the default resolution of this stream is 1280x720 @ 15 frames per second
6
Low quality stream: the address is:
rtsp://ip address of your camera:88/videoSub (no spaces)
the default resolution of this stream is 640x480 @ 15 frames per second. This can be
useful if the internet connection is slow.
6DOOHjPDQJHU
The command for taking a snapshot with the camera is:
/cgi-bin/CGIProxy.fcgi?usr=your username &pwd=password&cmd=snapPicture2
8
&XLVLQH
kitchen
%XDQGHULH
%XDQGHULH
Settings
• To test the smoke detector, press the button located on the cover of the detector.
floor
5G&
5G&Ground
7
dining
room
6DOOHjPDQJHU
&XLVLQH
*DUDJH
*DUDJH
6DOOHjPDQJHU
dining
room
6DOOHjPDQJHU
(no spaces)
Permitted delay for loading the image capture. 5 seconds is a reasonable value; test
it if you want to change it.
bedroom
&KDPEUH
The FTP settings must be copied using your camera's Network menu - FTP Settings.
&KDPEUH
bedroom
&KDPEUH
&KDPEUH
Minimum protection
recommended
•
•
•
•
The indicator flashes red as soon as the button is pressed and the alarm is triggered if the electronic circuit, the siren and the battery are functioning.
If the alarm is not triggered, this means the battery or another component are faulty.
THE SMOKE DETECTOR MUST BE TESTED ONCE A MONTH TO ENSURE
OPTIMUM OPERATION.
A random or weak alarm noise coming from the detector may indicate the product
is faulty. In this case, stop using it.
Optimum protection
1
Precautions for positioning
2
corridor
&RXORLU
&RXORLU
(VFDOLHU
staircase
3
&KDPEUH
bedroom
(VFDOLHU
Floor
eWDJH
eWDJH
Pairing the product with the Thombox
• In order for the Thombox to inform you when the product detects smoke, it must be paired
with the Thombox.
• Remove the tab during the countdown. The detector beeps.
• Press the TEST button hard.
&KDPEUH
4
5
Rules for installation
• Install the smoke detector as near to the centre of the ceiling as possible (best configuration).
• Install the smoke detector high against the wall at a distance of between 10 cm and 30 cm
from the ceiling (acceptable configuration).
• In rooms with sloping ceilings, install the detector on one of the sloping sides of the roof
between 10 cm and 100 cm from the highest point.
6
Warning: the default address of your camera ends with ':88'; you should also copy it and the
IP address of your camera in the Thombox widget. Tick the relevant camera, then click on
Ajouter [Add].
Your camera will be configured automatically in the Thombox interface. Enter your username
and password:
1
2
You need to copy the FTP username as is
3
You need to copy the FTP password as is
4
The FTP port number is 21
5
The FTP port mode to use is PORT
6
Test the data you have entered by clicking on the Test button
If you want your camera to send images to the Thombox when motion is detected, click on
the 'Copier les réglages dans la caméra [Copy settings to camera]' button at the bottom of the
window. Your Thombox will then write the destination for the images to the camera settings.
This completes the configuration.
(Click on the
icon in the cameras widget on your Thombox to display more details on the
functions and options available).
the address to enter in the camera settings is:
ftp://FTP server address of the Thombox/FTP folder of the Thombox
>10 cm
>10 cm
>10 cm
<30 cm
• Once paired, the smoke detector appears in the "Capteur" (Sensor) Widget. If smoke is
detected, a red dot appears.
IMPORTANT:
Before permanently attaching your accessory, we advise you to check the range. To do so,
place your detector as close as possible to the place you wish to install it before you attach it
and test your accessory.
G7 - INDOOR SIREN
/($51
9
WARNING: For proper operation, the included indoor siren should be attached to the wall or if
not, temporarily placed on a flat surface (due to the anti-tamper detector on the back).
This indoor siren emits a loud noise in the event of intrusion into your home.
J1
Settings
Different settings are available on the inside of the siren:
anti-tamper device
U6
Switch up
Pairing with the Thombox
During the countdown, connect the siren battery and hold down the 'Learn' button for a few
seconds.
&76
&76
/($51
9
21
/($51
9
/($51
21
CTS
LEARN
ON
3 4
J4
&76
• Switch 4: must be left up.
• Switch 3: lower the switch to activate audio confirmation when arming and disarming.
9
Arming: 2 beeps, Disarming:
1 beep.
• Switch 2: lower the switch to activate visual confirmation when arming and disarming.
Arming: the red LED on the front blinks twice.
Disarming: the red LED on the front blinks once.
• Switch 1: allows you to select the length of time the alarm will sound for when it is triggered.
Lower the switch to set the siren duration to 3 minutes.
Raise the switch to set the siren duration to 1 minute.
21
2
J2
1
Switch down
Setup
H - TECHNICAL AND LEGAL INFORMATION
H1 - THOMBOX TECHNICAL
CHARACTERISTICS
• System:
Processors: ARM9 208MHz
Main memory: 32MB
Flash memory: 128MB
OS: Linux kernel 2.6
• Communication:
Network: Ethernet 10/100M
Radio: ARW 868.3MHz protocol
• Power supply:
Thombox: 9 to 12V DC (centre positive)
Mains adapter (included): 100~240V AC/50Hz
Power consumption: 1.2W at rest/2.4W max
• Operating conditions:
Temperature: Storage -25°C to 70°C, operation 0°C to 40°C
Humidity: 5% to 95% without condensation
• Dimensions: 86 x 86 x 48mm
ø8mm
MOTION DETECTOR
• Radio frequency: ARW 868.3MHz protocol
• Radio range: Up to 300m in open air*
• Power supply: 3V via a CR123A battery (included)
• Detection range: Up to 15m
• Angle of detection: 90°
• Operating temperature: -10°C to +50°C, indoor use only
• Pet-immune feature: Configurable to 15kg or 25kg
• Battery life: Up to 4 years
/($51
21
&76
21
&76
/($51
-
-
9
9
OPENING DETECTOR FOR DOORS AND WINDOWS
• Radio frequency: ARW 868.3MHz protocol
• Radio range: Up to 300m in open air*
• Power supply: 3V via a CR123A battery (included)
• Operating temperature: -10°C to +50°C, indoor use only
• Maximum distance between sensor and magnet: 12mm
• Battery life: Up to 4 years
&76
&76
/($51
9
/($51
21
21
9
*The indicated radio range refers to the open air range, i.e. no obstacles between
the receiver and the transmitter. Any obstacle or disturbance will reduce this range.
H2 - WARRANTY
• This product is guaranteed for parts and labour for 2 years from the date of purchase. Proof
of purchase must be retained for the duration of the warranty period.
• The warranty does not cover damage caused by negligence, knocks, or accidents.
• This product must not be opened or repaired by any persons not employed by AVIDSEN
except to insert or replace the batteries.
• The warranty will be void if the device is tampered with.
• Consumables such as batteries are not covered by the warranty.
150m
AVIDSEN hereby declares that the following equipment: Stand-alone radio smoke detector
alarm reference 510722
Complies with the R&TTE 1999/5/CE directive and its conformity has been
assessed pursuant to the applicable standards in force.
Signed at Chambray les Tours on 25/9/14 by
Alexandre Chaverot, CEO
Visit our website to find out more about our Thomson
Connected Home range on
www.thomsonbox.eu
H3 - ASSISTANCE AND ADVICE
• If, in spite of the care we have taken in designing our products and drafting these instructions,
you do encounter difficulties when installing your product or you have any questions, we
urge you to contact one of our specialists who will be glad to help.
• If you encounter operating problems during the installation or a few days afterwards, it is
essential that you are in front of your installation when contacting us, so that one of our
technicians can diagnose the source of the problem, as it will probably be the result of a
setting that is incorrect or an installation that is not to specification. If the problem is caused
by the product itself, the technician will give you an RMA number so that you can return the
unit to the shop.
Without this RMA number, the shop may refuse to exchange your product.
Any help during the installation of your Thombox, or during the association of your Thomson
Connected Homes range devices? Please call our technical team at the following number:
Helpline: +33 892 701 369.
(Audiotel: €0.337/min incl. VAT)
Monday to Friday, 9 AM to 12 PM and 2 PM to 6 PM.
/($51
&76
/($51
21
&76
9
INDOOR SIREN
• Radio frequency: ARW 868.3MHz protocol
• Radio range: Up to 300m in open air*
• Power supply: 3.6V via an ER34615M battery (included)
• Operating temperature: -10°C to +50°C, indoor use only
• Sound power level: >100dBa
• Battery life: Up to 4 years with one alarm per month
AVIDSEN hereby declares that the following equipment: Premium Security Pack reference
510764
Complies with the R&TTE 1999/5/CE directive and that its conformity has been assessed
pursuant to the applicable standards in force:
EN60950-1:2006+A11:2009+A1:2010+A12 :2011
EN60669-1:1999+A1:2002+A2:2008
EN60669-2-1:2004
EN14604
EN50130-4:1995+A1:1998+A2:2003
EN301489-1 V1.8.1
EN301489-1 V1.9.2
13
EN301 489-17 V2.1.1
0333
CPR-292056-1
EN301489-3 V1.4.1
EN300220-2 V2.3.1
EN300220-2 V2.4.1
EN300 328 V1.7.1
EN 62311:2008
EN 301 489-17 V2.2.1
EN 300 328 V1.8.1
BATTERY MODULE
• Power: supplied by the Thombox
• Battery: Li-ion 3500 mAh 7.4V
• Battery life: approximately 24h
SMOKE DETECTOR
• Power supplied by a non-replaceable battery (included).
• Battery life: 10 years.
• Radio frequency: ARW 868.3MHz protocol
• Radio range: 150m in open space. Any obstacle or disturbance will reduce this range.
• Operating temperature: 0°C to 40°C.
• Sound power level: 85dB(A) min. at 3m.
• Dimensions: Ø105mm x 69mm.
• For indoor use only.
• Standard: EN 14604:2005/AC:2008
With the R&TTE directive
21
9
720p IP camera
• Power supply: 5VDC / 2000mA
• Network interface: Ethernet cable 10/100 or WiFi 802.11 b/g/n
• Manual or automatic infra-red night vision, 8m range
• Compression: h264
• Resolution: 720p (main stream), VGA (secondary stream)
• Operating temperature: 0°C to 40°C
H4 - DECLARATION OF CONFORMITY
REMOTE CONTROL
• Radio frequency:
ARW 868.3MHz protocol
• Radio range:
Up to 300m in open air*
• Power supply:
3V via a CR2032 battery (included)
• Operating temperature:
-0°C to +50°C, indoor use only
Connect the battery wires to the '3.6V' connector on the siren electronic card. The detector
beeps briefly.
3G KEY
• Connectors: USB
• Card format: SIM
• Mobile network: GPRS/3G
• Data usage: varies according to use, approximately 20Mb per 24h period
• Operating temperature: -10°C to +40°C
• Humidity: 5% à 95%
• For indoor use only
is a TECHNICOLOR S.A. brand
used under licence by:
Avidsen France S.A.S.- 32, rue Augustin Fresnel