3 phase programmable rish pgd3a / pgd3v

3 PHASE PROGRAMMABLE RISH
PGD3A / PGD3V
Application:
The digital panel meters RISH
have been designed for
industrial applications, which frequently require precise and onsite adjustment of the display range. It can be used in industrial
automation and for laboratory uses.
RISH DPM measures important electrical parameters in 3 phase 4
Wire, 3 phase 3 Wire and single phase Network & replaces the
multiple analog panel meters.
Salient Features:
 Fast & Easy Installation on panel without any need of
external swivel screws (clip-in mounting for 96x96 size only)
 True RMS measurement.
 4 Digits ultra bright LED Display (up to 9999).
 On site Programmable CT/PT Ratios.
 User selectable CT Secondary 1A/5A.
 User selectable PT Secondary from 100 VLL to 500 VLL.
 User selectable 3ph3wire / 3ph4wire / single phase
Network.
 Wide auxillary Power Supply which can accept any input
between 40V – 300V AC/DC.
 Storage of MIN / MAX values.
Products Features:
True RMS measurement
The instrument measures distorted waveform up to 15th
Harmonic.
On site programmable PT/CT ratios:
It is possible to program primary of external potential Transformer
(PT) for Voltage DPM & primary of external Current Transformer
(CT) for Current DPM on site via front panel keys by entering into
Programming mode.
User selectable CT Secondary 5A/1A
The secondary of external Current Transformer (CT) can be
programmed on site to either 5A or 1A for Current DPM using
front panel keys.
User selectable PT Primary
The Primary of Potential transformer can be programmed on site
from 100V to 999kV for Voltage DPM using front panel keys.
User selectable PT Secondary
The secondary of external Potential Transformer (PT) can be
programmed on site from 100 VLL to 500 VLL for Voltage DPM
using front panel keys.
User selectable 3 phase 3Wire or 4Wire or Single phase
Network
User can program on site the network connection as either 3
Phase 3 Wire or 4 Wire or single phase network using front panel
keys.
Higher Security
Provides Security with user programmable password protection.
User selectable CT Primary
The Primary of current transformer can be programmed on site
from 1A to 999kA for Current DPM using front panel keys.
Onsite selection of Auto scroll / Fixed Screen
User can set the display in auto scrolling mode or fixed screen
mode using front panel keys.
RISHABH INSTRUMENTS PVT.LTD.
F-31, MIDC, Satpur, Nashik-422 007,India.
Tel.: +91 253 2202160, 2202202 Fax : +91 253 2351064
E-mail : India :- marketing@rishabh.co.in
International :- exp.marketing@rishabh.co.in
www.rishabh.co.in
Page 1/7
Rev : G 12/14
PGD3A / PGD3V
3 PHASE PROGRAMMABLE RISH
Available in two different Sizes:
DPM is available in two different sizes 96x96 and 48x96.
4 digits LED display (up to 9999):
14mm or 20mm ultra bright 4 digits LED display.
Enclosure Protection for dust and water:
Conforms to IP 50 (for front face) & IP 20 (for back) & as per
IEC60529.
Function keys:
Using two function keys it is possible to Display various
parameters in Current and Voltage DPM. These function keys are
also used for programming Password, Network selection, CT/PT
Primary & Secondary values, Reset min/max values, Auto
ON/OFF mode selection.
EMC Compatibility
Compliance to International standard IEC 61326.
 Interference Emission : IEC 61326-1 : 2005, Class A
 Interference Immunity : IEC 61326-1 : 2005
 Electrostatic discharge : IEC 61000-4-2 -- 4kV/8kV
contact/air. (ESD)
 EM Field
: IEC 61000-4-3 -- 10 V/m
(80 MHz to 1 GHz)
– 3 V/m (1.4 Ghz to 2 GHz)
-- 1 V/m (2 GHz to 2.7 GHz)
 Burst
: IEC 61000-4-4 -- 2 kV (5/50 ns, 5 kHz)
 Surge
: IEC 61000-4-5 -- 1 kVLL / 2 kVLN.
 Conducted RF
: IEC 61000-4-5 -- 3 V
(150 kHz to 80 MHZ)
 Rated Power Frequency
magnetic Field
: IEC 61000-4-8 -- 30 A/m
 Voltage dip
: IEC 61000-4-11 -- 0% during 1 cycle.
-- 40% during 10/12 cycles.
-- 70% during 25/30 cycles.
 Short interruptions
: IEC 61000-4-11 –
0% during 25/30 cycles.
25 cycles for 50 Hz test.
30 cycles for 60 Hz test.
Screen No. storage
In case of power failure, the instrument memorizes the last
screen stored. For every 1 min. the instrument stores the screen
no. in the non-volatile memory.
Min Max storage of parameters possible
The instrument stores minimum and maximum values for System
Voltage(in case of PGD3V) and System Current (in case of
PGD3A). Every 60 sec stored values are updated.
Low back depth
The instrument has very low back depth (behind the panel) of less
than 54mm for 96x96 and 68mm for 48x96 type DPM.
Technical Specifications:
Input Voltage (PGD3V):
Nominal input voltage (AC RMS)
Max continuous input voltage
Nominal input voltage burden
System PT secondary values
System PT primary values
Phase –Neutral 290V L-N , Line-Line 500V L-L
120% of rated value
< 0.3 VA approx. per phase.
100VLL to 500VLL programmable on site.
100VLL to 999kVLL programmable on site.
Input Current (PGD3A):
Nominal input current
System CT secondary values
System CT primary values
Max continuous input current
Nominal input current burden
5A AC RMS
1A & 5A programmable on site.
From 1A up to 999kA (for 1 or 5 Amp )
120% of rated value
< 0.2 VA approx. per phase
Auxiliary Supply:
External Aux
Frequency range
VA burden
40 V – 300V AC-DC
45 to 65 Hz
3 VA Approx.
Overload Withstand:
Voltage
Current
2 x rated value for 1 second, repeated 10 times at 10 second intervals
20x rated value for 1 second, repeated 5 times at 5 min intervals
(± 5 % )
RISHABH INSTRUMENTS PVT.LTD.
F-31, MIDC, Satpur, Nashik-422 007,India.
Tel.: +91 253 2202160, 2202202 Fax : +91 253 2351064
E-mail : India :- marketing@rishabh.co.in
International :- exp.marketing@rishabh.co.in
www.rishabh.co.in
Page 2/7
Rev : G 12/14
PGD3A / PGD3V
3 PHASE PROGRAMMABLE RISH
Technical Specifications:
Operating Measuring Ranges:
Voltage Range
Current Range
Frequency
10… 120% of rated value
10 … 120% of rated value
45…65 Hz
Reference conditions for Accuracy:
Reference temperature
Input waveform
Input frequency
Auxiliary supply voltage
Auxiliary supply frequency
23°C +/- 2°C
Sinusoidal (distortion factor 0.005)
50 or 60 Hz ±2%
Rated Value ±1%
Rated Value ±1%
Accuracy:
Voltage
Current
±0.5% of range + 1 Digit (10... 100% of Nominal value)
±0.5% of range + 1 Digit (10... 100% of Nominal value)
Influence of Variations:
Temperature coefficient :
(for rated value range of use (0…50°C))
0.05%/°C for Current
0.025%/°C for Voltage
Display update rate:
Response time to step input
1 sec approx.
Applicable Standards:
EMC
Safety
IP for water & dust
IEC 61326-1: 2005
IEC 61010-1-2001 , Permanently connected use
IEC60529
Safety :
Pollution degree:
Installation category:
High Voltage Test
2
III
3.3 kV AC, 50Hz for 1 minute between Aux. and measuring inputs
Environmental:
Operating temperature
Storage temperature
Relative humidity
Warm up time
Shock
Vibration
0 to +50°C
-25°C to +70°C
0... 90% non condensing
Minimum 3 minute
15g in 3 planes
10... 55 Hz, 0.15mm amplitude
RISHABH INSTRUMENTS PVT.LTD.
F-31, MIDC, Satpur, Nashik-422 007,India.
Tel.: +91 253 2202160, 2202202 Fax : +91 253 2351064
E-mail : India :- marketing@rishabh.co.in
International :- exp.marketing@rishabh.co.in
www.rishabh.co.in
Page 3/7
Rev : G 12/14
PGD3A / PGD3V
3 PHASE PROGRAMMABLE RISH
Technical Specifications:
Enclosure:
Front
Back
IP 50.
IP 20.
Dimensions and Weights:
a) 96x96 DPM
Bezel size
Panel cut-out
Overall depth
Weight
96 mm x 96 mm DIN 43 718.
92 +0.8 mm x 92 + 0.8 mm.
55 mm.
310 gm. Approx.
b) 48x96 DPM
Bezel size
Panel cut-out
Overall depth
Weight
96 mm x 48 mm DIN 43 718
92 + 0.8 mm x 43.5 + 0.6 mm.
68 mm.
250 gm. Approx.
Parameters measured and displayed:
A) PGD3V
B) PGD3A
Network
type
Displayed
Parameter
Network
type
1) 3 Phase 4 wire
a. Phase –Neutral Voltage VR
b. Phase –Neutral Voltage VY
c. Phase –Neutral Voltage VB
d. Line-Line Voltage VRY
e. Line-Line Voltage VYB
f. Line-Line Voltage VBR
g. System Voltage V
h. Max. system voltage V
i.Min. system voltage V
1) 3 Phase 4 wire
and 3 Phase 3 Wire
2) 3 Phase 3 wire
a. Line-Line Voltage VRY
b. Line-Line Voltage VYB
c. Line-Line Voltage VBR
d. System Voltage V
e. Max. system voltage V
f. Min. system voltage V
3) 1 Phase 2 wire
a. Phase –Neutral Voltage V
b. Max voltage V
c. Min voltage V
2) 1 Phase 2 wire
Displayed
Parameter
a. Phase Current AR
b. Phase Current AY
c. Phase Current AB
d. System Current A
e. Max. system Current A
f. Min. system Current A
a. Phase Current A
e. Max. Phase Current A
f. Min. Phase Current A
RISHABH INSTRUMENTS PVT.LTD.
F-31, MIDC, Satpur, Nashik-422 007,India.
Tel.: +91 253 2202160, 2202202 Fax : +91 253 2351064
E-mail : India :- marketing@rishabh.co.in
International :- exp.marketing@rishabh.co.in
www.rishabh.co.in
Page 4/7
Rev : G 12/14
PGD3A / PGD3V
3 PHASE PROGRAMMABLE RISH
Connection Diagram:A
A) For 96x96 DPM
5
2
11
8
13
14
L
N
2
8
5
13
14
L
N
2
-
+
L1
L2
L3
N
L
O
A
D
AUX
SUPPLY
L1
L2
L3
N
Connection For PGD3V
3PH - 4 Wire Network
1
3
6
4
9
7
13
14
L
N
1
3
9
7
AUX
SUPPLY
L
O
A
D
13
14
L
N
AUX
SUPPLY
L1
L2
L3
Connection For PGD3A
3PH - 4 Wire Network
14
L
N
-
AUX
SUPPLY
L1
N
L
O
A
D
Connection For PGD1V
1PH Network
3
1
-
+
L
O
A
D
13
+
Connection For PGD3V
3PH - 3 Wire Network
-
+
L1
L2
L3
-
+
AUX
SUPPLY
11
13
14
L
N
-
+
L
O
A
D
AUX
SUPPLY
L1
L2
L3
Connection For PGD3A
3PH - 3 Wire Network
L
O
A
D
Connection For PGD3A
1PH Network
*Note: For Measurement of parameters in PGD3V DPM Voltage must be present between terminal 2 & 11 (L1 phase) for single
phase or 3 phase 4 wire network and between terminal 2 & 5 (L12 phase) or 2 & 8 (L31 phase) for 3 phase 3 wire network.
And for PGD3A DPM current must be present between terminal 1 & 3 (L1 phase) for 3 phase 4 wire or 3 phase 3 wire or single
phase network.
B) For 48x96 DPM
6
8
1
3
B
A
L
N
8
3
6
B
A
L
N
8
-
+
+
AUX
SUPPLY
L1
L2
L3
N
L
O
A
D
AUX
SUPPLY
L1
L2
L3
1
3
6
7
9
10
B
A
L
N
+
L1
L2
L3
1
3
9
10
-
AUX
SUPPLY
Connection For PGD3A
3PH - 4 Wire Network
L
O
A
D
B
A
L
N
+
L
O
A
D
A
L
N
Connection For PGD3A
3PH - 3 Wire Network
-
AUX
SUPPLY
L1
N
L
O
A
D
Connection For PGD3V
1PH Network
9
-
AUX
SUPPLY
L1
L2
L3
B
+
Connection For PGD3V
3PH - 3 Wire Network
Connection For PGD3V
3PH - 4 Wire Network
1
-
10
B
A
L
N
+
L
O
A
D
-
AUX
SUPPLY
L1
N
L
O
A
D
Connection For PGD3A
1PH Network
*Note: For Measurement of parameters in PGD3V LD DPM Voltage must be present between terminal 8 & 1 (L1 phase) for single
phase or 3 phase 4 wire network and between terminal 6 & 8 (L12 phase) or 3 & 8 (L13 phase) for 3 phase 3 wire network.
And for PGD3A LD DPM current must be present between terminal 9 & 10 (L1 Phase) for 3 phase 4 wire or 3 phase 3 wire or single
phase network.
RISHABH INSTRUMENTS PVT.LTD.
F-31, MIDC, Satpur, Nashik-422 007,India.
Tel.: +91 253 2202160, 2202202 Fax : +91 253 2351064
E-mail : India :- marketing@rishabh.co.in
International :- exp.marketing@rishabh.co.in
www.rishabh.co.in
Page 5/7
Rev : G 12/14
3 PHASE PROGRAMMABLE RISH
PGD3A / PGD3V
Installation:
Easy Clip in Installation on Panel for 96 x 96 size:
Easy Clip - in
mounting
Swivel screw
Panel Thickness : 1 - 3 mm for self clicking,
1 – 6 mm for swivel screws.
A) For 96x96 DPM
55 mm
92mm+0.8
Display Area
92mm+0.8
96 mm
96 mm
4 mm
42 mm
Panel Cutout
B) For 48x96 DPM
Mounting Position
Installation Cutout
RISHABH INSTRUMENTS PVT.LTD.
F-31, MIDC, Satpur, Nashik-422 007,India.
Tel.: +91 253 2202160, 2202202 Fax : +91 253 2351064
E-mail : India :- marketing@rishabh.co.in
International :- exp.marketing@rishabh.co.in
www.rishabh.co.in
Page 6/7
Rev : G 12/14
PGD3A / PGD3V
3 PHASE PROGRAMMABLE RISH
Ordering information
Ordering Code
PROGRAMMABLE RISH DPM
DPM Panel Cutout
96x96 DPM
48x96 Low Depth DPM
96x96
48x96
Parameter Type
3 Phase Current
3 Phase Voltage
PGD3A
PGD3V
Display Type
14mm Display digit height
20mm Display digit height
(available in 96x96 size only)
14mm
20mm
Order Code Example:
PROGRAMMABLE RISH DPM– 48x96 - PGD3A – 14mm
PROGRAMMABLE RISH DPM, 48x96 Low Depth, 3 Phase Current, 14mm display digit height, Aux. – 40-300V AC/DC
*Note: For measurement of parameters R phase voltage (for PGD3V) or R phase current (for PGD3A)
Must always be present.
RISHABH INSTRUMENTS PVT.LTD.
F-31, MIDC, Satpur, Nashik-422 007,India.
Tel.: +91 253 2202160, 2202202 Fax : +91 253 2351064
E-mail : India :- marketing@rishabh.co.in
International :- exp.marketing@rishabh.co.in
www.rishabh.co.in
Page 7/7
Rev : G 12/14
1 PHASE PROGRAMMABLE RISH
PGDA / PGDV
Application:
The digital panel meters RISH
have been designed for
industrial applications, which frequently require precise and onsite adjustment of the display range.
It can be used in industrial automation and for laboratory uses.
Salient Features:
 Fast & Easy Installation on panel without any need of
external swivel screws (clip-in mounting for 96x96 size only)
 True RMS measurement.
 4 Digits ultra bright LED Display (up to 9999).
 On site Programmable CT/PT Ratios.
 User selectable CT Secondary 1A/5A.
 User selectable PT Secondary from 60 VLN to 290 VLN.
 Wide auxillary Power Supply which can accept any input
between 40V – 300V AC/DC.
 Storage of MIN / MAX values.
Products Features:
True RMS measurement
The instrument measures distorted waveform up to 15th
Harmonic.
On site programmable PT/CT ratios:
It is possible to program primary of external potential Transformer
(PT) for Voltage DPM & primary of external Current Transformer
(CT) for Current DPM on site via front panel keys by entering into
Programming mode.
User selectable CT Secondary 5A/1A
The secondary of external Current Transformer (CT) can be
programmed on site to either 5A or 1A for Current DPM using
front panel keys.
User selectable PT Secondary
The secondary of external Potential Transformer (PT) can be
programmed on site from 60 VLN to 290 VLN for Voltage DPM
using front panel keys.
Onsite selection of Auto scroll / Fixed Screen
User can set the display in auto scrolling mode or fixed screen
mode using front panel keys.
User selectable CT Primary
The Primary of current transformer can be programmed on site
from 1A to 999kA for Current DPM using front panel keys.
4 digits LED display (up to 9999):
14mm or 20mm ultra bright 4 digits LED display.
User selectable PT Primary
The Primary of Potential transformer can be programmed on site
from 60 VLN to 999 kVLN for Voltage DPM using front panel keys.
Higher Security
Provides Security with user programmable password protection.
RISHABH INSTRUMENTS PVT.LTD.
F-31, MIDC, Satpur, Nashik-422 007,India.
Tel.: +91 253 2202160, 2202202 Fax : +91 253 2351064
E-mail : India :- marketing@rishabh.co.in
International :- exp.marketing@rishabh.co.in
www.rishabh.co.in
Page 1/6
Rev : E 12/14
PGDA / PGDV
1 PHASE PROGRAMMABLE RISH
EMC Compatibility
Compliance to International standard IEC 61326.
 Interference Emission : IEC 61326-1 : 2005, Class A
 Interference Immunity : IEC 61326-1 : 2005
 Electrostatic discharge : IEC 61000-4-2 -- 4kV/8kV
contact/air. (ESD)
 EM Field
: IEC 61000-4-3 -- 10 V/m
(80 MHz to 1 GHz)
– 3 V/m (1.4 Ghz to 2 GHz)
-- 1 V/m (2 GHz to 2.7 GHz)
 Burst
: IEC 61000-4-4 -- 2 kV (5/50 ns, 5 kHz)
 Surge
: IEC 61000-4-5 -- 1 kVLL / 2 kVLN.
 Conducted RF
: IEC 61000-4-5 -- 3 V
(150 kHz to 80 Mhz)
 Rated Power Frequency
magnetic Field
: IEC 61000-4-8 -- 30 A/m
 Voltage dip
: IEC 61000-4-11 -- 0% during 1 cycle.
-- 40% during 10/12 cycles.
-- 70% during 25/30 cycles.
 Short interruptions
: IEC 61000-4-11 –
0% during 25/30 cycles.
25 cycles for 50 Hz test.
30 cycles for 60 Hz test.
Function keys:
Using two function keys it is possible to Display various
parameters in Current and Voltage DPM. These function keys are
also used for programming Password, CT/PT Primary &
Secondary values, Reset min/max values, Auto ON/OFF mode
selection.
Screen No. storage
In case of power failure, the instrument memorizes the last
screen stored. For every 1 min. the instrument stores the screen
no. in the non-volatile memory.
Min Max storage of parameters possible
The instrument stores minimum and maximum values for Voltage
(in case of PGDV) and Current (in case of PGDA). Every 60 sec
stored values are updated.
Low back depth
The instrument has very low back depth (behind the panel) of less
than 54mm for 96x96 and 68mm for 48x96 type DPM.
Enclosure Protection for dust and water:
Conforms to IP 50 (for front face) & IP 20 (for back) & as per
IEC60529.
Technical Specifications:
Input Voltage (PGDV):
Nominal input voltage (AC RMS)
Max continuous input voltage
Nominal input voltage burden
System PT secondary values
System PT primary values
Phase –Neutral 290VL-N .
120% of rated value
< 0.3 VA approx.
60VLN to 290VLN programmable on site.
60VLN to 999kVLN programmable on site.
Input Current (PGDA):
Nominal input current
System CT secondary values
System CT primary values
Max continuous input current
Nominal input current burden
5A AC RMS
1A & 5A programmable on site.
From 1A up to 999kA (for 1 or 5 Amp )
120% of rated value
< 0.2 VA approx. per phase
Auxiliary Supply:
External Aux
Frequency range
VA burden
40 V – 300V AC/DC
45 to 65 Hz
3 VA Approx.
(± 5 % )
RISHABH INSTRUMENTS PVT.LTD.
F-31, MIDC, Satpur, Nashik-422 007,India.
Tel.: +91 253 2202160, 2202202 Fax : +91 253 2351064
E-mail : India :- marketing@rishabh.co.in
International :- exp.marketing@rishabh.co.in
www.rishabh.co.in
Page 2/6
Rev : E 12/14
PGDA / PGDV
1 PHASE PROGRAMMABLE RISH
Technical Specifications:
Environmental:
Operating temperature
Storage temperature
Relative humidity
Warm up time
Shock
Vibration
0 to +50°C
-25°C to +70°C
0... 90% non condensing
Minimum 3 minute
15g in 3 planes
10... 55 Hz, 0.15mm amplitude
Enclosure:
Front
Back
IP 50.
IP 20.
Dimensions and Weights :
a) 96x96 DPM
Bezel size
Panel cut-out
Overall depth
Weight
b) 48x96 DPM
Bezel size
Panel cut-out
Overall depth
Weight
96 mm x 96 mm DIN 43 718.
92 +0.8 mm x 92 + 0.8 mm.
55 mm.
300 gm. Approx.
96 mm x 48 mm DIN 43 718
92 + 0.8 mm x 43.5 + 0.6 mm.
68 mm.
250 gm. Approx.
45…65 Hz
Overload Withstand:
Voltage
Current
2 x rated value for 1 second, repeated 10 times at 10 second intervals
20x rated value for 1 second, repeated 5 times at 5 min intervals
Operating Measuring Ranges:
Voltage Range
Current Range
Frequency
10… 120% of rated value
10 … 120% of rated value
45...65 Hz
Reference conditions for Accuracy:
Reference temperature
Input waveform
Input frequency
Auxiliary supply voltage
Auxiliary supply frequency
23°C +/- 2°C
Sinusoidal (distortion factor 0.005)
50 or 60 Hz ±2%
Rated Value ±1%
Rated Value ±1%
Accuracy:
Voltage
Current
±0.5% of range + 1 Digit (10... 100% of Nominal value)
±0.5% of range + 1 Digit (10... 100% of Nominal value)
RISHABH INSTRUMENTS PVT.LTD.
F-31, MIDC, Satpur, Nashik-422 007,India.
Tel.: +91 253 2202160, 2202202 Fax : +91 253 2351064
E-mail : India :- marketing@rishabh.co.in
International :- exp.marketing@rishabh.co.in
www.rishabh.co.in
Page 3/6
Rev : E 12/14
PGDA / PGDV
1 PHASE PROGRAMMABLE RISH
Technical Specifications:
Influence of Variations:
Temperature coefficient :
(for rated value range of use (0…50°C))
0.025%/°C for Voltage
0.05%/°C for Current
Display update rate:
Response time to step input
1 sec approx.
Applicable Standards:
EMC
Safety
IP for water & dust
IEC 61326-1: 2005
IEC 61010-1-2001 , Permanently connected use
IEC60529
Safety :
Pollution degree:
Installation category:
High Voltage Test
2
III
3.3 kV AC, 50Hz for 1 minute between Aux. and measuring inputs
Electrical Connections:
A) For 96x96 DPM
1
3
13
14
L
N
+
3
-
AUX
SUPPLY
L1
N
1
13
14
L
N
+
L
O
A
D
Connection For PGDV
1PH Network
-
AUX
SUPPLY
L1
N
L
O
A
D
Connection For PGDA
1PH Network
B) For 48x96 DPM
1
3
A
B
L
N
+
L1
N
1
3
-
AUX
SUPPLY
Connection For PGDV
1PH Network
A
B
L
N
+
L
O
A
D
-
AUX
SUPPLY
L1
N
L
O
A
D
Connection For PGDA
1PH Network
RISHABH INSTRUMENTS PVT.LTD.
F-31, MIDC, Satpur, Nashik-422 007,India.
Tel.: +91 253 2202160, 2202202 Fax : +91 253 2351064
E-mail : India :- marketing@rishabh.co.in
International :- exp.marketing@rishabh.co.in
www.rishabh.co.in
Page 4/6
Rev : E 12/14
PGDA / PGDV
1 PHASE PROGRAMMABLE RISH
Installation:
Easy Clip in Installation on Panel for 96 x 96 size:
Easy Clip - in
mounting
Swivel screw
Panel Thickness : 1 - 3 mm for self clicking,
1 – 6 mm for swivel screws.
A) For 96x96 DPM
55 mm
92mm+0.8
Display Area
92mm+0.8
96 mm
96 mm
4 mm
42 mm
Panel Cutout
B) For 48x96 DPM
Mounting Position
Installation Cutout
RISHABH INSTRUMENTS PVT.LTD.
F-31, MIDC, Satpur, Nashik-422 007,India.
Tel.: +91 253 2202160, 2202202 Fax : +91 253 2351064
E-mail : India :- marketing@rishabh.co.in
International :- exp.marketing@rishabh.co.in
www.rishabh.co.in
Page 5/6
Rev : E 12/14
PGDA / PGDV
1 PHASE PROGRAMMABLE RISH
Ordering information
Ordering Code
PROGRAMMABLE RISH DPM
DPM Panel Cutout
96x96 DPM
48x96 Low Depth DPM
96x96
48x96
Parameter Type
Phase Current
Phase Voltage
PGDA
PGDV
Display Type
14mm Display digit height
20mm Display digit height
(available in 96x96 size only)
14mm
20mm
Order Code Example:
PROGRAMMABLE RISH DPM– 96x96 - PGDV – 20mm
PROGRAMMABLE RISH DPM, 96x96, 1 Phase Voltage, 20mm display digit height, Aux. – 40-300V AC/DC
RISHABH INSTRUMENTS PVT.LTD.
F-31, MIDC, Satpur, Nashik-422 007,India.
Tel.: +91 253 2202160, 2202202 Fax : +91 253 2351064
E-mail : India :- marketing@rishabh.co.in
International :- exp.marketing@rishabh.co.in
www.rishabh.co.in
Page 6/6
Rev : E 12/14
Download PDF