Manual
i200
Mobeye Argos
SW version 6.n
Attention! Very important
This user manual contains important guidelines for the installation and
usage of the Mobeye Argos. Please read these thoroughly before you start
using the Mobeye Argos!
In case of damage caused by disregarding the guidelines, the warranty
becomes void.
The user must regularly check the proper functioning of the Mobeye Argos.
The manufacturer cannot be held liable for any damage or loss caused by
any incorrect use or incorrect functioning of the Mobeye Argos.
Safety guidelines
• The permitted ambient temperature during operation may not be
exceeded (not lower than -10°C and not higher than 55°C).
• The device is intended for use in dry and clean places.
• Protect the device from moisture, heat and water splashing. Not
intended for external use.
• The guidelines for the battery usage must be regarded.
• Do not expose the device to strong vibrations.
• Do not let it fall from height.
• Do not use in an environment where any inflammable gases, vapours or
dust are present or could be present.
• Repair of the device may only be carried out by people, trained for
Mobeye® repair.
• If the device must be repaired, only original replacement components
may be used. The use of different parts may lead to damage of the
Mobeye Argos.
Use in accordance with the regulations
The purpose of this device in accordance with the regulations is the
generation of SMS text messages and telephone calls after detection of
motion by the motion detector, if the measured temperature outreaches
the programmed limits, after the activation of one of the inputs, or after an
internal trigger; switching the outputs after an alarm or via incoming
call/SMS. Other uses are not permitted.
Table of Content
1.
Introduction
1
2.
2.1
2.2
2.3
2.4
To get ready in four steps
Step 1: SIM Card
Step 2: inserting the batteries
Step 3: Program the phone numbers
Step 4: Check the settings
2
2
2
2
3
3.1
3.2
Intruder alarm: operation
Switching on and off
Alarm message, confirmation and listen-in
4
4
4
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.10
4.11
4.12
4.13
4.14
4.15
4.16
Intruder alarm: basic functions
Configuration
Installation code
User code
SMS custom text
Telephone numbers
SMS ON/OFF
CALL ON/OFF
Sensor sensitivity
Entry delay
Entry indication
Siren
Exit indication
Interval test message
Set actual time and date
Automatic time-based arm/disarm
Inactive time after a movement detection
5
5
6
6
6
7
7
7
7
7
7
8
8
8
8
8
8
5.1
5.2
5.3
5.4
5.5
Temperature alarm
Configuration
Monitoring the temperature limits
Adjusting the temperature
Delay time
Alarm repeat
9
9
9
10
10
10
6.1
6.2
6.3
6.4
6.5
Advanced options
Request the list of settings
Reset to factory settings
Leave the menu
Position of Mobeye Argos
Test GSM network strength
11
11
11
11
11
12
7.
Connecting sensors, devices external power
13
8.
Inputs
Configuration
Alarm text
Input type
Input delay time
14
14
15
15
15
3.
4.
5.
6.
8.1
8.2
8.3
8.4
8.5
8.6
8.7
Inactive time
PIR sensor on/off
Alarm repeat
15
15
15
9.1
9.2
9.3
9.4
9.5
External power supply
Configuration
Sensitivity PIR
Power failure message
Power failure delay time
Authorisations and remote control
16
16
17
17
17
17
10.1
10.2
10.3
10.4
Outputs
Configuration
Duration of outputs: Switch or pulse times
Switch behavior
Authorising telephone numbers
18
18
19
19
19
11.
Mobeye Internet Portal
20
12.
Programming via SMS text messages
Program mode
How to Program by SMS
21
21
21
13.
Complete list of settings
22
14.
Reports and lists
Status request
List of settings
Authorisation list
24
24
24
24
Issue solving and technical data
25
9.
10.
12.1
12.2
14.1
14.2
14.3
15.
1. INTRODUCTION
The Mobeye Argos is an easy to install alarm
system that will notify you about an activation
using the built-in GSM communication module.
To use the Mobeye Argos you will need a SIMcard from any network.
Typical applications are the security of places
without any power supply or the temporary security of properties.
The Mobeye Argos has the following features:
Alarm notifications after movement detection
In case of the detection of an intruder, the Mobeye Argos will send an SMS
text message to your phone(s). The Mobeye Argos will also call the phone
numbers in order to be sure the message is not missed. It is also possible
to set on the siren sound. After an alarm the Mobeye will be in standby
status for about 5 minutes. Following the standby period, the Mobeye will
resume alerting you to new movement.
Alarm notifications after detection of out of range temperature
It is possible to program a minimum and/or maximum temperature alert in
to the Mobeye Argos. The system will monitor the actual temperature of its
environment and send an alert as soon as the temperature reaches the
limit.
Battery operated or using the mains
Although the Mobeye Argos is designed to run on batteries, it is possible to
use an external power supply. When powering the Mobeye Argos with
mains, it notifies the first set telephone number if the power fails and that it
has switched to battery backup. It is also possible to remotely control the
system when using mains power.
Connecting external sensors and devices
In addition to the integrated movement sensor and temperature sensor,
external sensors can be connected. The Mobeye Argos can also switch
external devices connected to it via the outputs when an event triggers it
(such as an alarm or incoming call).
Private numbers or Mobeye Internet Portal
The Mobeye Argos sends alarm messages to a maximum of five
telephone numbers. As an option the Mobeye Argos can be connected to
the Mobeye Internet Portal, which is explained in chapter 11.
Low battery message
The Mobeye Argos will send an SMS text message when the batteries
need to be replaced. When receiving this message, you need to change
the batteries as soon as possible, although the Mobeye Argos remains
functioning for a short time following the message. Even when the Mobeye
Argos is unset, it will measure the battery strength and send the message.
1
2. TO GET READY IN FOUR STEPS
To get started with the Mobeye Argos only four steps are needed.
1. Place the SIM card in the Mobeye Argos.
Make sure this SIM card is not secured by a PIN code.
2. Insert the four batteries.
3. Enter at least one phone number in the Mobeye Argos.
4. Check the settings
In this chapter these steps are explained.
2.1 STEP 1: SIM CARD
To use the Mobeye Argos a SIM card from any network is needed. On this
SIM card, the PIN code security needs to be disabled or 0000. If you have
a SIM card with PIN code, you can disable or change this using any mobile
phone and change the PIN code security. Please consult the manual for
that mobile phone for the procedure.
The SIM card needs to be inserted before the
batteries. When using a prepaid SIM card, take note
of the available credit. Additionally it is wise to set a
recurrent test message in the menu so the card will
be used at least once a month.
 Open the back cover
 Insert the SIM card in the holder. For
opening/closing, move the cover slightly.
2.2 STEP 2: INSERTING THE BATTERIES
Insert the four lithium 3,0 volt batteries (CR123). When replacing the
batteries, all settings remain unchanged.
After inserting the SIM card and the batteries, the Mobeye Argos will
perform a self test taking 1 minute. During the test, the light is red.
If the light is flashing red, a problem with the SIM card is detected. A
reason could be no SIM card was placed, or the PIN code security of the
SIM card was not disabled.
Close the Mobeye Argos using the 4 screws.
2.3 STEP 3: PROGRAM THE PHONE NUMBERS
You need to program at least one phone number in the unit as alarm
number.






Enter your 4 digit code (factory setting: “1111”)
Press “menu”
Enter “101”
Press “OK”
Enter the phone number (e.g. 0712345678 or 0044712345678)
Press “OK”
The light turns green and a confirmation melody is played.
The Mobeye Argos is ready to use.
2
2.4 STEP 4: CHECK THE SETTINGS
The settings can be sent to the programmed telephone number as SMS
text message. In this way you also check the correct working of the SIM
card.
 Enter your 4 digit code (factory setting: “1111”)
 Press “menu”
 Enter “10”
 Press “OK”
Within ca. 30 seconds the programmed phone number will receive the list
with settings.
3
3. INTRUDER ALARM: OPERATION
3.1 SWITCHING ON AND OFF
To activate the Mobeye Argos movement detector, use the installation
code or user code.
 Enter your code
 Press “OK”
The light turns red shortly and an indication tone is started. This
repetitive tone will last during the exit delay of 60 seconds. As soon as
the acoustic signal stops, the Mobeye Argos is active.
- If the code is entered incorrectly 3 times, the indicator turns red and the
Mobeye Argos will be blocked for 10 minutes.
- The action can be interrupted at any time, by twice pressing “OK”.
- The entry indication and siren are off as factory default. Look at the next
chapter how to activate them.
To de-activate the Mobeye Argos movement detector with your code.
 Enter your code
 Press “OK”
The light switches to green and a confirmation melody is played.
The system needs to be switched on and off using the same code; the
installation code and user code are not interchangeable.
3.2 ALARM MESSAGE, CONFIRMATION AND LISTEN-IN
When the armed system detects a movement, it first waits for the entry
delay period and then it alarms. During the entry delay the GSM module
starts to establish a connection to the network. If the system was not
disarmed, the alarm messages follow. First an SMS text message is sent
to all programmed alarm numbers; next a phone call is made to the
numbers. When you answer the phone, a beep tone is heard.
Confirm using “1”
It is possible to confirm the phone call by answering the phone and
pressing “1“. The other alarm numbers will not be called afterwards.
Listen-in using “9”
It is possible to start a listen-in connection by answering the phone call and
pressing “9”. You will then be able to hear anything in the immediate
vicinity of the Mobeye Argos. If the siren was set to “loud”, it is stopped.
After two minutes one hears two short beeps; if one presses “9” again, the
listen-in is extended by another two minutes. By pressing “9” the call is
confirmed as well and the other alarm numbers will not be called
afterwards.
4
4. INTRUDER ALARM: BASIC FUNCTIONS
The Mobeye Argos settings can be changed via the keypad. First the
method of programming is discussed, next the explanation of the settings.
This chapter describes the settings for the ‘all-in-one’ basic system.
Advanced options like using the external inputs, outputs, or external power
supply can be found in chapter 7 and further.
4.1 CONFIGURATION
To change the settings, please follow these instructions:
 Enter your 4-digit code (factory setting is
“1111”)
 Press “menu” - light turns green
 Enter the menu number (see list below)
 Press “OK”
 Enter the new setting
 Press “OK”. The light switches off, a
confirmation melody is played
In the event of an incorrect entry, the light turns red and a short beep
sounds. The menu can be left from any position, by twice pressing “OK”.
Following settings are possible:
Menu
nr.
Description
Options
Factory
settings
00
101
102
103
104
105
03
04
05
Installation code
1st tel. number
2nd tel. number
3rd tel. number
4th tel. number
5th tel. number
Sensitivity PIR
Entry delay
Interval test message
4-digit code
Tel. number
1111
-
07
Entry indication
08
09
12
13
50
60
61
Siren
Exit indication
SMS on/off
Call on/off
User code
Actual time
Actual date
0 (off), 1 (beep on),
2 (LED on)
0 (off), 1 (on)
0 (off), 1 (on)
0 (off), 1 (on)
0 (off), 1 (on)
4-digit
hhmm (e.g.1530)
yyyymmdd
62
63
Automatic arming time hhmm (0 to delete)
Automatic disarming
hhmm (0 to delete)
time
Inactive time PIR
00..60 (min.)
(0 to delete)
1(high), 2 (low)
1, 15, 30, 45 or 60
0-30 (days)
1 (high)
15
0 (no
message)
0 (off)
0 (off)
1 (on)
1 (on)
1 (on)
8888
(e.g. 20140331)
79
0 (empty)
0 (empty)
5
The menu can be left from any position, by twice pressing “OK”.
5
4.2 INSTALLATION CODE
The installation code is the 4-digit code for switching on/off and
programming the settings or activating the special functions. Factory
default is “1111”. It is possible to change the code to any 4-digit number.
Please change the code to make the unit more secure.
4.3 USER CODE
The Mobeye Argos offers the possibility to set a personal 4-digit user code,
for just arming and disarming the system. It is not possible to change the
settings with the user code. The system needs to be switched on and off
using the same code; the installation code and user code are not
interchangeable. Factory settings for the user code is “8888”. This code
can be changed by the installation code or user code (menu number 50).
We recommend that you change this code to make the unit more secure.
4.4 SMS CUSTOM TEXT
It is possible to add a custom text in the SMS text messages, to identify
the Mobeye Argos unit that sent the message. The second part of the SMS
text message contains a standard text like ‘Mobeye alarm’, or ‘Test
message OK’. The custom text will be written before the standard text.
This custom text (max. 20 characters) is programmed by sending an SMS
to the Mobeye Argos. Changing the custom text cannot be done via the
keypad, only via sending an SMS text message.
Switch the Mobeye Argos into the programming mode. In this mode the
GSM module is switched on and is able to receive messages.




Enter your 4-digit personal code. (factory setting: “1111”)
Press “menu”
Press “21” -> light turns green
Press “OK”
First the light flashes red (interval ca. 1 sec). As soon as the light turns
green, the Mobeye Argos is able to receive SMS-messages.
To program the custom text, send an SMS in following structure:
1111 NAME:myowntext
-
‘1111’ stands for the installation code (1111)
‘NAME’ is a standard command (capitals)
Replace ‘myowntext’ by a self-defined text (max. 20 characters)
Be aware of the space after 1111 and the colon after NAME
You will hear two short beeps in case of a correct command.
Leave the menu by pressing “OK” twice.
6
4.5 TELEPHONE NUMBERS
Up to five telephone numbers can be programmed in to the Mobeye Argos.
In the event of an alarm the Mobeye Argos first sends an SMS text
message to all numbers, next they are called. It is possible to confirm the
call, after which the other numbers will not be called anymore. Or to start a
listen-in connection.
Note: The first telephone number is required, the others are optional.
4.6 SMS ON/OFF
By default, the Mobeye Argos sends alarm notifications via text message
and calls to the preset contact persons. By turning off the SMS, the unit
will only call after the movement sensors send an alarm. Regardless of this
setting the temperature alarm always sends an SMS including the actual
temperature.
4.7 CALL ON/OFF
By default, the Mobeye Argos sends alarm notifications via text message
and calls to the preset contact persons. By turning off the CALL, the unit
will only send an SMS text message as alarm notification. It is not possible
to switch off both the SMS and the call.
4.8 SENSOR SENSITIVITY
The detectors’ sensitivity can be changed to a high or low value.
1= High
2 = Low
In the high sensitivity mode each detection will generate an alarm. In the
lower sensitivity mode the alarm will be generated only when the detector
is activated twice in any 15 second period. This mode prevents false
alarms in case of e.g. draught and is most suitable if the sensor is directed
towards an open space.
4.9 ENTRY DELAY
It is possible to choose from 5 entry delay times (1,15, 30, 45 and 60
seconds). The entry delay is the time between the moment of detection
and the moment of sending the first SMS text message.
Important note: If the GSM network has low signal strength, the time can
be longer as the network connection may not be established within the
time of the entry delay.
4.10 ENTRY INDICATION
No entry indication is set as the factory default. It is possible to hear an
indication beep during the entry delay. This can be used as a reminder that
the Mobeye is in active mode. It is also possible to just let the LED
indicator flash a few times, as an indication for the user.
7
4.11 SIREN
After the entry delay, the siren can sound for two minutes. At the same
time the SMS text messages and telephone calls will be sent. At soon as
the Mobeye is switched off, the siren will stop. The siren is set to silent as
the factory default.
4.12 EXIT INDICATION
Upon arming the system, you have one minute to leave the room. The PIR
is not active yet and an exit indication sounds. It is possible to change this
to a silent exit time. A short beep is heard and the LED flashes red during
the exit time.
4.13 INTERVAL TEST MESSAGE
The Mobeye Argos can send test messages. Through these ‘keep alive’
reports you will be informed about the status of your Mobeye Argos. You
can set the interval between the test reports. This is adjustable between 0
(no test reported) and 30 (every 30 days a test message). Note: the
interval of 1 day will result in a daily test message; the exact time between
the messages will be about 24 hours.
The smaller the interval between the test reports, the shorter is the battery
life. The test message only works if the system is on or a temperature limit
is set.
4.14 SET ACTUAL TIME AND DATE
If the system is to be armed automatically, the internal clock time needs to
be correct. Some Telecom providers offer this in the network, to be
synchronised by the Mobeye Argos during the start-up and after sending
test messages. It is possible to set the time and date manually. To view
the clock time, send a list of the settings to the first programmed phone
number (CODE MENU 10 OK).
4.15 AUTOMATIC TIME-BASED ARM/DISARM
The Mobeye Argos can be armed and/or disarmed based on a daily time
schedule. If the exit indication was set to ‘silent’, the system makes no
noise during arming and disarming. The first telephone number needs to
be set before the arming and/or disarming time can be set.
4.16 INACTIVE TIME AFTER A MOVEMENT DETECTION
The “PIR inactive time” is the time the movement sensor is inactive after
having seen and reported movement. If the time is set to “5” (minutes), the
sensor will only report new movements after a minimum of 5 minutes after
the previous movement.
The inactive time can be set in minutes from 0 to 999. As factory default
the inactive time is set to “5”.
8
5. TEMPERATURE ALARM
5.1 CONFIGURATION
To change the settings, please follow these instructions:
 Enter your 4-digit code (factory setting is “1111”)
 Press “menu” - light turns green
 Enter the menu number (see list below)
 Press “OK”
 Enter the new setting
 Press “OK”. The light switches off, a confirmation melody is played
In the event of an incorrect entry, the light turns red and a short beep
sounds. The menu can be left from any position, by twice pressing “OK”.
Following settings are possible:
Menu
nr.
Description
Options
Factory
setting
41
Minimum
temperature limit
999 (off)
42
Maximum
temperature limit
000-050 (0 to 50ºC)
110 -101 (-10 to -1ºC)
999 = off
000-050 (0 to 50ºC)
110-101 (-10 to -1ºC)
49
Correction factor
temperature
999 = off
01-09 (+1 to +9ºC)
11-19 (-1 to -9ºC)
78
84
Delay temperature
alarm
Repeat time
999 (off)
00
00 (no correction)
00..60 (min.)
1
0..99 (hours)
4
5.2 MONITORING THE TEMPERATURE LIMITS
The Mobeye Argos is able to send a temperature alarm as soon as the
actual temperature reaches a programmed min. or max. level. This
function can be used independently of the motion detection. As soon as
the temperature is too high or too low, an SMS text message is sent,
followed by a telephone call. As long as the out of range temperature
remains, the report will be repeated every four hours (factory default).
Once the temperature is back to normal, the Mobeye Argos confirms this
to you.
This function is active as soon as a temperature limit is programmed. By
resetting the limits, the function becomes inactive.
9
5.3 ADJUSTING THE TEMPERATURE
The built-in temperature sensor may have a standard deviation of the
actual temperature. In this case, the deviation will be similar at all
temperatures. It is possible to correct the temperature deviation in the
Mobeye Argos. In the SMS setting summary, you see the reported
temperature. If a correction is specified, it is processed in the displayed
temperature; the correction factor itself is displayed separately.
Example: Mobeye temperature: 13 °C. Actual temperature: 14 °C. To
correct this deviation, one degree should be added.
5.4 DELAY TIME
The temperature delay time defines the duration a temperature limit is
exceeded before an alarm is initiated. If the temperature returns to the nonalarm status within the delay time, no alarm is sent. The delay time can be
set between 0 and 999 minutes.
As default, the temperature delay time is set to 0 minutes.
5.5 ALARM REPEAT
In order to emphasize the urgency of the alarm messages, the
temperature alarm (and alarms on the inputs 1 and 2) can be repeated. As
long as the alarm status has not returned to the inactive status, the SMS
alarm will be repeated after the ‘alarm repeat time’ (as long as the alarm
SMS is “ON”). In the repeated temperature alarm message the actual
temperature is mentioned as well, to follow the temperature development.
The time can be set between 0 and 24 hours. As default the alarm repeat
time is set to 4 hours.
10
6. ADVANCED OPTIONS
6.1 REQUEST THE LIST OF SETTINGS
The settings can be sent to the set telephone number as SMS text
message. In this way you also check the correct working of the SIM card.
 Enter the 4 digit installation code (factory setting: “1111”)
 Press “menu”
 Enter “10”
 Press “OK”
Within ca. 30 seconds the programmed phone number will receive the list
of settings.
The advanced settings are listed in the ‘advanced setting list’:
 Enter your 4 digit installation code (factory setting: “1111”)
 Press “menu”
 Enter “11”
 Press “OK”
Within ca. 30 seconds the programmed phone number will receive the list
with advanced settings.
6.2 RESET TO FACTORY SETTINGS
It is possible to reset the Mobeye Argos to factory settings.
 Enter your 4 digit installation code (factory setting: “1111”)
 Press “menu”
 Enter “99”
 Press “OK”
After several seconds a short confirmation tone is heard. The installation
code is also reset to 1111.
6.3 LEAVE THE MENU
The menu can be left from any position, by twice pressing “OK”.
6.4 POSITION OF MOBEYE ARGOS
The built-in motion sensor has a 360º detection pattern and has a range of
about 8 meters. The Mobeye Argos can be positioned both vertically as
horizontally. It can be mounted to the wall, put down on its side in a
cabinet, put down with its sensor upward or downward. In case you wish to
hang the Mobeye Argos, the pre-punched holes can be opened, in order to
hang it on screws.
11
In order to check the positioning of the sensor, a sensor test can be
executed.
 Enter the installation code
 Press “menu”
 Press “511”
 Press “OK”
 A confirmation beep is heard. First the green light will be flashing. After
about 30 seconds the light will be on continuously.
In this mode the sensor test can be done; each time the sensor detects a
movement, a repeating beep will sound.
Leave the test by entering OK twice.
6.5 TEST GSM NETWORK STRENGTH
Before using the Mobeye Argos is it advised to test the GSM signal
strength at the location.
 Enter the installation code
 Press “menu”
 Press “512”
 Press “OK”
The Mobeye Argos now switches on the GSM module and searches for all
available networks. It also checks the network strength of the SIM card
provider in the device.
As soon as the GSM network is found, the light will turn green.
The GSM signal strength for the network your SIM is using can be gauged
from the LED indicator:
LED
Green during 30 seconds
Flashing green
Red
Flashing red
Description
Signal is very good
Signal is good
Signal is weak
Searching, no valid SIM card or SIM
card is not pin code free or no signal
The telephone number at memory position 01 will receive an SMS text
message, containing all existing GSM networks, sorted by provider. It also
tells the strength of each network.
This search function can take a few minutes. If you want to leave the
function before it is ready, please press “OK” twice.
Warning
In the event of a weak signal, the Mobeye Argos can still be used, but
there is a risk that messages cannot be sent or will be received with a
delay. In case of no signal, it is advised to try a different network.
12
7. CONNECTING SENSORS, DEVICES AND EXTERNAL POWER
In addition to the integrated movement sensor and temperature sensor,
external sensors can be connected as alarm input. The Mobeye Argos can
also switch external devices connected to it via the outputs when an event
triggers it (like an alarm or incoming call).
And although the Mobeye Argos is designed to run on batteries, it is
possible to use an external power supply in order to report power failure
and to remotely control the system.
In following chapters the inputs, outputs and external power settings are
explained. Please find below the architecture of the main unit.
13
8. INPUTS
External sensors can be connected to the inputs. Upon closing (or
opening) an input, the Mobeye Argos will send an alarm message to the
set alarm numbers (factory default: SMS and call).
1) Replace the
white grommet
with the rubber
ring (using a
tool)
2) Insert the 2 wires of an
external sensor through the
hole to the inside and in to
the two connectors of input 1
(press the orange pins).
3) Be sure the wires
are laid between the
tapped holes and the
wall of the casing
before closing.
When using a second input, connect this to input 2.
8.1 CONFIGURATION
To change the settings, please follow these instructions:
 Enter your 4-digit code (factory setting is “1111”)
 Press “menu” - light turns green
 Enter the menu number (see list below)
 Press “OK”
 Enter the new setting
 Press “OK”. The light switches off, a confirmation
melody is played
In the event of a incorrect entry, the light turns red and a short beep
sounds. The menu can be left from any position, by twice pressing “OK”.
Following settings are possible:
Menu
nr.
71
Description
Options
Input type input 1
72
Input type input 2
73
74
Inactive time input 1
Inactive time input 2
Inactive time PIR
PIR on/off
Delay input 1
Delay input 2
Repeat time
0 (off), 1 (normally
opened), 2 (normally
closed)
0 (off), 1 (normally
opened), 2 (normally
closed)
0..999 (min.)
0..999 (min.)
00..60 (min.)
0 (off), 1 (on)
00..999 (sec.)
00..999 (sec.)
0..99 (hours)
79
70
75
76
84
Factory
setting
1 (NO)
1 (NO)
5
5
5
1 (on)
1
1
4
14
8.2 ALARM TEXT
Custom alarm texts can be programmed. These texts have a maximum
length of 20 characters.
The following texts are programmed as factory default:
Triggered input 1
Triggered input 2
TEXT1: alarm 1
TEXT2: alarm 2
The alarm text can be changed by SMS command (see chapter 12 for
explanation):
SMS command TEXT1: CODE TEXT1:free text
SMS command TEXT2: CODE TEXT2: free text
8.3 INPUT TYPE
The input type defines the character of the inputs IN1 and IN2. This can be
Normally Open (NO) or Normally Closed (NC). If an input is set to NO, the
alarm will be triggered as soon as the terminals of the input are closed. If
the input is set to NC, the alarm is triggered if the connection between the
input terminals is broken. The default input type is set to NO.
8.4 INPUT DELAY TIME
The input delay time defines the time that the inputs are triggered before
an alarm is initiated. If the input returns to the non-alarm status within the
delay time, no alarm is sent. The delay time can be set between 0 and 999
seconds.
As default, the input delay time is set to 1 second.
8.5 INACTIVE TIME
The “inactive time” defines the time the movement sensor, input 1 or input
2 is not active after an activation. If the time is set to “0” (minutes), the
input is active again immediately after returning to the non-alarm status. If
the time is set to e.g. 30 minutes, the input remains inactive for the first 30
minutes. If the input is again (or still) activated after these 30 minutes, a
new alarm message is sent. The inactive time can be set between 0 and
60 minutes. As default, the inactive time is set to “5” for all inputs.
8.6 PIR SENSOR ON/OFF
If the inputs are in use, it could be useful to de-activate the integrated
movement sensor (PIR). The Mobeye Argos will then cease activating
alarms when movement is detected until this function is reinstated. As
factory settings the PIR is ON.
8.7 ALARM REPEAT
See 5.5 for explanation.
15
9. EXTERNAL POWER SUPPLY
Although the Mobeye Argos is designed to run on batteries, it is possible to
use an external power supply (9-24VDC). In this mode the module is
always in connection with the GSM network. The advantage of external
power is the longer battery lifetime, to receive power failure messages and
the possibility to perform remote actions, like arm/disarm, switch the
outputs, ask status reports and to program it via SMS-commands. Be
aware: the PIR sensor will be slightly less sensitive when using external
power supply.
1) Replace the
white grommet
with the rubber
ring (using a
tool)
2) Insert the 2 wires through
the hole to the inside part and
in to the two connectors
(press the orange pins):
V+
to “+”
“Ground” to “-“
3) Be sure the wires
are laid between
the tapped holes
and the wall of the
casing
before
closing.
Article 10027: black wire with white line is “+”, black wire is “-“
9.1 CONFIGURATION
To change the settings, please follow these instructions:
 Enter your 4-digit code (factory setting is “1111”)
 Press “menu” - light turns green
 Enter the menu number (see list below)
 Press “OK”
 Enter the new setting
 Press “OK”. The light switches off, a confirmation
melody is played
In the event of an incorrect entry, the light turns red and a short beep
sounds. The menu can be left from any position, by twice pressing “OK”.
Following settings are possible:
Menu
nr.
86
77
Description
Options
Power failure message
Power failure delay time
0 (off), 1 (on)
00..60 (min)
201…
210
Authorise telephone
number
Factory
setting
1 (on)
1
Telephone number
(0 to delete)
16
9.2 SENSITIVITY PIR
Using an external power source, the internal PIR sensor will react slight
slower after detecting movements, even when the sensitivity is set to
‘high’. Be sure the sensor is positioned well, so the intruder can be seen
while walking or working. Please test the PIR positioning to ensure the PIR
detects you in the areas you are trying to secure.
9.3 POWER FAILURE MESSAGE
Upon a power outage the batteries take over functioning. A ‘power failure’
SMS text message is sent to the first telephone number. The GSM
module turns to the low power status, meaning it closes and only
establishes network connection in case it needs to send a message
(alarm, test, battery low).
The power failure message can be deactivated (OFF). As factory default
the power failure message is set to ‘ON’.
9.4 POWER FAILURE DELAY TIME
The power failure delay time defines the time that the power fails before an
alarm is initiated. If the power is restored within the delay time, no alarm is
sent. The delay time can be set between 0 and 60 minutes. As default, the
delay time is set to 1.
9.5 AUTHORISATIONS AND REMOTE CONTROL
When connected to an external power, the GSM module is active all the
time, able to receive SMS commands. This enables both programming and
remote control. Remote control actions are: arming, disarming and
switching the outputs. As prerequisite for remote control the ‘controlling
telephone number’ needs to be authorised. . A maximum of ten numbers
can be authorised via keypad or SMS command. If it is not clear what
memory positions are available, it is possible to add a new number by the
SMS command ‘ADDTELA’ . The new number takes the first free position.
To receive a list with the authorised numbers, please refer to paragraph
14.3.
SMS-commands for remote control (no code is necessary, but numbers
need to be authorised):
Arm:
ARM
Disarm:
DISARM
Switch on output 1:
O1ON
Switch off output 1:
O1OFF
17
10. OUTPUTS
The Mobeye Argos has two outputs (O1 and O2).These (dry) relay outputs
can switch external devices. The maximum load is 2A/30V per output.
Output 1 is free to use for an external device. Switching the relay can be
done in several ways: after an alarm, upon arming, upon disarming or
remote (via SMS or call).
Output 2 (O2) is configured for an external siren. This output reacts similar
to the internal siren; if this is set to ‘silent’, O2 does not react. Upon a
(loud) alarm, it switches for 2 minutes.
1) Replace the white
grommet with the
rubber ring (using a
tool)
2) Insert the 2 wires
through the hole in to the
terminal connectors (press
the orange pins):
3) Be sure the wires are
laid between the tapped
holes and the wall of the
casing before closing
the casing.
10.1 CONFIGURATION
To change the settings, please follow the instructions:
 Enter your 4-digit code (factory setting is “1111”)
 Press “menu” -> light turns green
 Enter the menu number (see list below)
 Press “OK”
 Enter the new setting
 Press “OK”. The light switches off, a confirmation
melody is played
In the event of an incorrect entry, the light turns red and a short beep sounds.
The menu can be left from any position, by twice pressing “OK”.
Following settings are possible:
Menu
nr.
81
82
201…
210
83
Description
Options
Duration of output 1
Duration of output 2
Authorised telephone
number
Behaviour output 1
1..9999 (sec)
1..9999 (sec)
Telephone number (0 to
delete)
1 (RC), 2 (ARMED),
3 (DISARMED),
4 (INTRUDER), 5 (TEMP)
Factory
setting
0
120
1 (RC)
18
10.2 DURATION OF OUTPUTS: SWITCH OR PULSE TIMES
If an output is used, the time this output is activated can be set between 1
and 999 seconds. If the setting is set to 0, the output does not return to its
previous state automatically. An authorised number can switch it back by
the SMS command O1OFF (see 9.5). In the factory settings the duration of
the pulse time for output 1 is “0” and for output 2 “120”.
10.3 SWITCH BEHAVIOR
The reason why output 1 is switched can be configured. Choices are:
switch by remote control (RC), switch when arming the Mobeye Argos
(ARMED), switch when disarming the Mobeye Argos (DISARMED), switch
upon an intruder alarm (alarm on PIR, IN1 or IN2), switch upon a
temperature alarm (temp). For remote control (switch via SMS-commands,
please refer to 9.5), the senders’ telephone number needs to be
authorised. In the factory settings the switch behaviour of output 1 is set to
‘RC’.
10.4 AUTHORISING TELEPHONE NUMBERS
For remote control by telephone (arm, disarm, switch outputs), the
telephone numbers need to be ‘authorised’. A maximum of ten numbers
can be authorised via keypad or SMS command. In case it is not clear
which memory position is free, it is possible to add a new number by the
SMS command ‘ADDTELA’ . The new number takes the first free position.
To receive a list with the authorised numbers, please refer to paragraph
14.3.
19
11. MOBEYE INTERNET PORTAL
The Mobeye Argos sends GSM messages to the pre-set contact persons.
It is also possible to connect the system to the Mobeye Internet Portal. In
this secured internet environment the Mobeye Argos systems can be
administered. The portal offers various functions:
1) the portal dispatches alarm messages to contact persons (SMS
and/or mail), which are set in the portal. Different persons can be set
for alarm messages versus technical message.
2) the name and location can be set in the portal. This name is used in
SMS and mail messages.
3) the portal will check the receipt of test messages (‘keep alive’); in
case the message was not received on time, it sends an exception
message.
Please contact Mobeye for more information.
It is also possible to connect the Mobeye Argos to an alarm receiving
centre (ARC), if this ARC has an SMS receiver.
Please contact Mobeye for more information.
20
12. PROGRAMMING VIA SMS TEXT MESSAGES
Almost all options can be set via the keypad. It is also possible to program
by sending SMS commands to the SIM cards’ telephone number in the
Mobeye Argos.
12.1 PROGRAM MODE
If the unit runs on external power, it is always in program mode, ready to
receive SMS commands. For programming a battery operated Mobeye
Argos, first switch to the program mode::




Enter your 4-digit code
Press “menu” -> light turns green
Enter “21”
Press “OK”
First the light flashes red (interval ca. 1 sec). As soon as the light turns
green, the Mobeye Argos is able to receive SMS-messages.
After five minutes there is a time-out and a beep is heard. Leave the
program mode earlier by pressing “OK” twice.
12.2 HOW TO PROGRAM BY SMS
- Be sure the unit is in program mode
- Send an SMS message with following content:
CODE COMMAND:OPTION
-
The CODE stands for the installation code. Factory setting is “1111”.
Do not forget the space between CODE and COMMAND.
The complete scheme with SMS commands is listed chapter 13.
The commands are case sensitive.
Several commands may be combined in one SMS message (with a
maximum of 160 characters) by placing a # between the commands.
CODE COMMAND:OPTION#COMMAND:OPTION#COMMAND:OPTION
A confirmation melody is played to indicate a correct command. In the
event of an incorrect command, a beep is heard.
Examples (code is 1111):
To switch off exit indication
1111 EXITBEEP:OFF
To set the minimum temperature (lower limit) to 5 degrees:
1111 LTL:+05
Or: both commands in one message:
1111 EXITBEEP:OFF#LTL:+05
21
13. COMPLETE LIST OF SETTINGS
Setting
Installation code
Sensitivity PIR
Entry delay
Interval test
message
Entry indication
Sirene
Exit indication
SMS on/off
CALL on/off
Select ARC
ARC client
number.
ARC telephone
number
Keypad
SMS
Keypad
SMS
Keypad
SMS
Keypad
SMS
Keypad
SMS
Keypad
SMS
Keypad
SMS
Keypad
SMS
Keypad
SMS
Keypad
SMS
Keypad
SMS
Keypad
SMS
Menu/
command
00
INSTCODE:
03
SENS:
04
ENTRYDELAY:
05
TEST:
07
ENTRYBEEP:
08
SIREN:
09
EXITBEEP:
12
SMSALARM:
13
CALLALARM:
30
ARC:
31
ARCCLIENTNR:
32
ARCCALLERID:
Change minimum Keypad
temperature
SMS
41
Change maximum Keypad
temperature
SMS
42
Keypad
49
Correction factor
temperature
SMS
Keypad
User code
SMS
Keypad
Actual time
SMS
Keypad
Actual date
SMS
Automatic arming Keypad
time
SMS
Keypad
Automatic
disarming time
SMS
Keypad
PIR on/off
SMS
Keypad
Input type input 1
SMS
Keypad
Input type input 2
SMS
Keypad
Inactive time
Input 1
SMS
Keypad
Inactive time
input 2
SMS
Keypad
Delay time input 1
SMS
Keypad
Delay time input 2
SMS
LTL:
HTL:
TEMPOFFSET:
50
USERCODE:
60
SETTIME:
61
SETDATE:
62
TIMEARM:
63
TIMEDISARM:
70
PIR:
71
TYPEIN1:
72
TYPEIN2:
73
INACTIVEINP1:
74
INACTIVEINP2:
75
DELAY1:
76
DELAY2:
Options
Factory
default
4 digits
1111
1 (high) of 2 (low)
1 (high)
1, 15, 30, 45 or 60
15
0, 1, 2, 3, … or 30 (days)
0
0 (off), 1 (on), (LED)
ON, OFF, LED
0 (off), 1 (on)
ON, OFF
0 (off), 1 (on)
ON, OFF
0 (off), 1 (on)
ON, OFF
0 (off), 1 (on)
ON, OFF
00 (no), 01 (general)
00, 01
0 (OFF)
0 (OFF)
1 (ON)
1 (ON)
1 (ON)
00 (no)
5 digit client number
-
Telephone number
-
000-050 (0 to 50ºC)
110-101 (-10 to -1 ºC)
999 = off
-10 to +50
000-050 (0 to 50ºC)
110-101 (-10 to -1ºC)
999 = off
-10 to +50
01-09 (+1 to +9ºC)
11-19 (-1 to -9ºC)
00 (no correction)
-9 tot +9
4 digits
off
off
0
8888
hhmm
yyyymmdd
hhmm
hhmm (delete by “0”)
hhmm
hhmm (delete by “0”)
0 (off), 1 (on)
ON, OFF
0 (off), 1 (NO), 2 (NC)
OFF, NO, NC
0 (off), 1 (NO), 2 (NC)
OFF, NO, NC
1 (ON)
0..999 (min.)
5
0..999 (min.)
5
0..999 (sec.)
1
0..999 (sec.)
1 (NO)
1 (NO)
1
22
Setting
Power failure
delay time
Delay temperature
alarm
Inactive time PIR
Pulse time output
1
Pulse time
siren/output 2
Repeat
Power failure
message
TEL1
TEL2
TEL3
TEL4
TEL5
Delete telephone
number
Keypad
SMS
Keypad
SMS
Keypad
SMS
Keypad
SMS
Keypad
SMS
Keypad
SMS
Keypad
SMS
Keypad
SMS
Keypad
SMS
Keypad
SMS
Keypad
SMS
Keypad
SMS
Keypad
SMS
Keypad
Authorise
telephone number SMS
Delete authorised Keypad
number
SMS
Keypad
Behaviour
output 1
SMS
Keypad
SMS
Keypad
Alarm text input 1
SMS
Keypad
Alarm text input 2
SMS
Identification text
Menu/
command
77
DELAYPOW:
78
DELAYTEMP:
79
INACTIVEPIR:
81
TO1:
82
TO2:
84
REPEAT:
86
POWERSMS:
101
TEL1:
102
TEL2:
103
TEL3:
104
TEL4:
105
TEL5:
101…105
DEL1….DEL5
201…210
TELA1: ...TELA10:
of ADDTELA:
201…210
DELA:1..DELA:10
Options
Factory
default
00..60 (min.)
1
00..60 (min.)
1
0..999 (min.)
5
1..9999 (sec.)
0
1..9999 (sec.)
120
0..99 (hours)
4
0 (off), 1 (on)
ON / OFF
1 (ON)
Telephone number
Telephone number
Telephone number
Telephone number
Telephone number
0
Tel. number
0
1 (RC), 2 (ARMED), 3 (DISARMED), 4 (INTRUDER), 5 (TEMP)
RC, ARMED, DISARMED,
OUTPBEHAVIOR:
INTRUDER, TEMP
NAME:
20 characters
TEXT1:
20 characters
TEXT2:
20 characters
83
1 (RC)
Mobeye
Alarm 1
Alarm 2
Program method using the keypad:
CODE
menu
menu nr.
OK
option OK
Program method via SMS (in program mode):
CODE COMMAND:OPTION
Or several commands at once:
CODE COMMAND:OPTION#COMMAND:OPTION#COMMAND:OPTION
23
14. REPORTS AND LISTS
The programmed settings and the Mobeye Argos status can be requested
as SMS-text message via the keypad or SMS-command (for SMS: be sure
the unit is in program mode).
14.1 STATUS REQUEST
The status can be requested via ‘CODE menu 501 OK’ or by sending an
SMS with the content:
CODE STATUS?
The originator of the request receives the
armed/not armed status, the status of the inputs,
power and batteries as SMS text message.
14.2 LIST OF SETTINGS
The basic settings can be requested via ‘CODE menu 10 OK’ or by
sending an SMS with the content:
CODE SET?
The originator of the request receives the list of
basic settings.
The advanced settings can be requested via ‘CODE menu 11 OK’ or by
sending an SMS with the content:
CODE SETA?
The originator of the request receives the list of
advanced settings.
14.3 AUTHORISATION LIST
The list with authorised numbers for remote control can be requested via
‘CODE menu 200 OK’ or by sending an SMS with the content:
CODE ANL?
The originator of the request receives the
authorised numbers as list.
24
15. ISSUE SOLVING AND TECHNICAL DATA
Issues
Error
Possible reason
Solution
Mobeye Argos cannot be
switched on. You hear an
error tone, the red light is
turned on shortly.
No valid Telephone
number was entered.
Enter a valid
number.
The light is flashing red
during switching on.
No valid SIM card was
entered or the SIM card
was not made pin code
free.
Check the SIM
card.
It is impossible to change
the settings. After entering
your personal code,
followed by menu, the error
tone is played and the light
turns red.
Mobeye is activated.
Switch off the
Mobeye Argos.
No GSM signal during the
GSM test
No network is available,
belonging to the SIM
cards provider.
Choose another
network provider.
The light remains red.
You entered an
incorrect installation or
user code three times.
Wait 10 minutes
and then re-enter
the correct
installation or user
code.
You do not receive an SMS
with the settings.
Telephone number is
not correct.
Re-program the
telephone number
at position ‘01’
For other questions, please refer to the site www.mobeye.eu
Technical data
• GSM: Quad Band EGSM 850/900/1800/1900 MHz
compatible to the ETSI GSM Phase 2+ standard
• Output power:
Class 4 (2W @ 900 MHz)
Class 1 (1W @ 1800 and 1900 MHz)
• Temperature range: -10°C until +55°C
• Weight: ca. 290 gram incl. batteries
• Dimensions: 161 x 90 x 35 mm (LxWxH)
• Batteries: 4 x CR123 Lithium 3.0 V
• Power, battery operated: 50 μA, short peaks of max. 2 A
• Power, ext. powered: 50 mA, short peaks of max. 2 A
25
Declaration of Conformity
Herewith we, Mobeye, declare that the product
Mobeye i-200
is in compliance with the essential requirements of the
following European standards / EU Directives:
Directive 73/23/EEC (low voltage directive)
Directive IEC/EN 50130 Electromagnetic compatibility
Directive 1995/5/EC R&TTE (Radio &
Telecommunications Terminal Equipment)
The conformity with the essential requirements of
1995/5/EC has been verified against:
ETSI EN 301 489-1 V1.5.1
ETSI EN 301 489-7 V1.2.1
ETSI EN 301 511 V9.0.2
CENELEC EN 60950:2001
Mobeye B.V.
Poeldonkweg 5
5216 JX ‘s-Hertogenbosch
The Netherlands
Name: J.P.K. van de Vijver
Position:
Managing Director
Signature:
Date:
1 Augustus 2012
Support
For support on technical problems regarding Mobeye Argos please contact
info@mobeye.eu.
This manual is published by Mobeye.
All rights, the translation included are reserved. Any reproduction,
either photocopy, microfilm or saved in an automated data dictionary,
only after written approval of the Publisher. Reprinting, even in
summary, is prohibited.
This user manual meets the technical requirements at the moment of
printing. Changes in technology and equipment are reserved.
© Copyright 2015 by Mobeye, version i200EN150304