Liebert® SXTM
60kVA to 200kVA UPS
Three Phase Input,
Three Phase Output
Enabling Tomorrow’s
CRITICAL EDGE
INFRASTRUCTURE
We helped some of the largest names
in the industry bring new capacity online
faster and at a lower cost when search
and social media increased demand for
storage and computing.
We were the first to introduce an
integrated enclosure system to
distributed networks.
Our portfolio spans power, thermal and
infrastructure management products,
software and solutions.
2
Protecting your critical technologies takes
more than just great software and equipment.
It takes a level of experience that only comes
from years of finding solutions when the industry
needed them most. We were the first to protect
mainframes with precision cooling systems.
And now as challenges and demands
grow, we continue to find better ways
to help you strengthen your most vital
applications. Formerly the Network
Power business of Vertiv, we’ve brought
together the most trusted
and experienced names in critical
infrastructure.
Complemented by a network of nearly
250 service centers worldwide. It’s a
combination of experience and
resources that allow us to better adapt
to what’s needed, anticipate what’s next
and continue to find solutions in ways
other companies simply can’t.
Liebert® SXTM
60kVA to 200kVA UPS
Three Phase Input, Three Phase Output
Liebert® SXTM features a full IGBT double conversion technology allowing it
to provide extraordinary savings on installation and running costs, while
at the same time providing first class load protection.
Maximized Active power, high efficiency
and complete compatibility for modern
mission critical IT and industrial loads
THDi < 3%
Clean grid
>0.99
NO deration
through
entire load
PF range
Input PF > 0.99
Maximum
power availability
• High efficiency upto 96%
in dual conversion mode
• 98% in Digital interactive mode
Automatic power
adjustment on
operating
temperature
Full galvanic isolation
as built-in option
Liebert® SXTM incorporates a full IGBT rectifier allowing for reductions in the size
of gensets, circuit protection, cabling and transformer.
3
Liebert® SXTM
60kVA to 200kVA UPS
Three Phase Input, Three Phase Output
Flexibility and
Compatibility
Liebert® SXTM can be fully adapted to
meet diverse requirements in terms
of battery backup time, power
redundancy and configuration.
Maximum flexibility is also
ensured from:
• Output Power Factor 1
• Output Power Factor diagram
symmetrical respect to zero
• Permanent 100% kVA - no derating
with any load (lagging or leading)
• Optimum space/power ratio
• Full compatibility with static transfer
switches
• Wide range of standard options
including: Isolation transformer
(integrated in UPS cabinet), System
Bypass Switch and Synchronization
Module (MBSM)
kVAr
Sustainability
Advanced digital technology and
maximum energy savings for increased
performance and optimized TCO.
100
Cos 0.5
80
Cos 0.8
60
Liebert® SXTM control platform incorporates double DSP, allowing it to provide
the most powerful control in the UPS
industry. Together with the patented
Vector Control technology it enables
an increased performance of power
converters and real time control of
output power quality. This combination
of technology provides the following
benefits:
• Zero impact on upstream
equipment
• Perfect compatibility with
generators
• Enhanced performance for
specific unbalanced load conditions
• Perfect load sharing for parallel
configurations
• Enhanced fault clearing capacity
(up to 300% of the inverter nominal
current)
• Intelligent double conversion for
maximum reliability and highest
energy savings.
Leading
100% KVA
Cos 0.9
40
100% KVA
20
Cos 1
0
100% KVA
20
40
Cos 0.9
60
Cos 0.8
80
Cos 0.6
Lagging
100
100% KVA
Full Galvanic Isolation
Integrated full galvanic isolation, meaning that UPS cabinet has a built- in
isolation transformer. This greatly reduces the footprint thus providing space
saving advantages. In addition, the transformer can be connected to the input or
to the output of the UPS, providing:
• Installation with two independent input sources ( with different neutrals)
• Installation in distribution without neutral
4
Liebert® SXTM
60kVA to 200kVA UPS
Three Phase Input, Three Phase Output
Energy Saving
Maximum Energy Savings
As a result of intelligent double
conversion technology, Liebert® SXTM
can achieve optimum efficiency values
in all operating conditions, making it
capable of reducing running costs also
at partial load. This architecture also
allows for reduced energy dissipation
(kW) thus significantly minimizing the
consumption of the cooling System.
Digital Interactive Mode (DIM)
If priority has been set to digital
interactive mode, intelligent double
conversion technology will allow
Liebert® SXTM to continuously monitor
the condition of the input supply,
including its failure rate, to ensure
maximum reliability for critical users.
On the basis of the analysis performed,
it will decide whether to supply the
load through the direct line or the
conditioned line. This operational
mode, which allows significant energy
savings by increasing the overall AC to
AC efficiency up to 98%.
• Upto 96% energy efficiency in dual conversion mode
• Upto 98% energy efficiency in Digital Interactive mode
Efficiency (%)
DIM
98
96
Double
Conversion
0 25 50
75
100 Load (%)
5
Liebert® SXTM
60kVA to 200kVA UPS
Three Phase Input, Three Phase Output
Commercial Tariff: Cost is based on Rs. 5 per kWH*
Rating
Traditional UPS
(=@92%) Energy
Charges(in INR)
(A)
Liebert SX UPS
(=@96%) Energy
Charges (in INR)
(B)
Annual Energy
Cost-Saving
(in INR)
(C=A-B)
Annual Aircon
Saving
(in INR)
(D)
Total Annual
Saving
(in INR)
(E=C+D)
Saving @
10 Years
(in INR)
60
2,856,522
2,737,500
119,022
56,110
175,132
1,751,317
80
3,808,696
3,650,000
158,696
74,814
233,510
2,335,097
100
4,760,870
4,562,500
198,370
93,517
291,887
2,918,866
120
5,713,043
5,475,000
238,043
112,220
350,263
3,502,635
160
7,617,391
7,300,000
317,391
149,627
467,018
4,670,183
200
9,521,739
9,125,000
396,739
187,034
583,773
5,837,731
Commercial Tariff: Cost is based on Rs. 7 per kWH*
Rating
Traditional UPS
(=@92%) Energy
Charges(in INR)
(A)
Liebert SX UPS
(=@96%) Energy
Charges (in INR)
(B)
Annual Energy
Cost-Saving
(in INR)
(C=A-B)
Annual Aircon
Saving
(in INR)
(D)
Total Annual
Saving
(in INR)
(E=C+D)
Saving @
10 Years
(in INR)
60
3,999,130
3,832,500
166,630
78,554
245,184
2,451,844
80
5,332,174
5,110,000
222,174
104,739
326,913
3,269,129
100
6,665,217
6,387,500
277,717
130,924
408,641
4,086,414
120
7,998,261
7,665,000
333,261
157,109
490,370
4,903,699
160
10,664,348
10,220,000
444,348
209,478
653,826
6,538,258
200
13,330,435
12,775,000
555,435
261,848
817,283
8,172,828
* Energy tariff assumed are the average electricity tariff in India
6
Liebert® SXTM
60kVA to 200kVA UPS
Three Phase Input, Three Phase Output
Respecting the environment
Environmental respect
Advanced battery care
Serviceability and Security
Liebert® SXTM meets our objective to
acknowledge its duty toward providing
the highest level of environmental
standards and encouraging environmental awareness, as a result of the
following features:
• Premium energy savings
• Maximized battery life with
Advanced Battery Care (ABC)
Using advanced battery care(ABC), the
Liebert® SXTM maximizes the running
time of the battery.
It has front access design. This
architecture considerably minimizes
the time needed for repairs and
optimizes installation and serviceability.
Features
• Ambient temperature compensated
battery charger
• Automatic battery test (can be set
by user at selectable intervals)
• Time compensated end of discharge
voltage
• Exact determination of remaining
battery life
Each UPS will be equipped with ID
card, including all UPS working
parameters. This card, uniquely related
to UPS, shortens UPS "off time" in case
where the control board needs to be
replaced.
Touch Screen Display
Hardware Connectivity
Software Connectivity
The control panel includes a touch
screen display for complete UPS
monitoring and control. The main page
of the touch screen displays a
single-line diagram of the UPS along
with the several menu items which
have detailed subsequent sections.
The display language is English only.
Manage UPS NET ensures the
monitoring and control of the
networked UPS, through the TCP/IP
protocol. Two different options permit:
• The integration UPS with Building
Monitoring and Automation
Systems via MODBUS RTU, MOD
BUS/TCP or JBUS protocols
• The monitoring of environmental
conditions where the UPS
systems are installed.
Multilink Professional provides the safe
shutdown of operating system in the
event of an interruption to the load.
This includes event logging and gives
notification vai e-mail.
Communication ports
Nform software provides a central
management system for critical power
infrastructures distributed within a
building, campus or wide area network
environment.
• Voltage-free contact ports
• Digital inputs and outputs
• Two serial ports and LAN
connection
• Two internal slots for LIFE.Net
and connectivity options.
7
Liebert® SXTM
60kVA to 200kVA UPS
Three Phase Input, Three Phase Output
Parallel Ready
Liebert® SXTM can be connected up to
eight units in parallel. A single
Liebert® SXTM unit can be upgraded to
parallel via easy to modify software
settings that allow the system to be
customized for the requested
configuration.
Liebert® SXTM self configuring, hot plug
parallel features means that the system
automatically selects when new units
have been added without the need for
stopping the system. This simplified
parallel process provides maximum
flexibility in terms of scalability for
capacity and redundancy.
AUTOMATIC AC BY-PASS
AC
AC
NORMAL NORMAL
AC
AC
AC
AC
AC
AC
NORMAL NORMAL NORMAL NORMAL NORMAL NORMAL
LOAD
8
Liebert® SXTM
60kVA to 200kVA UPS
Three Phase Input, Three Phase Output
Serviceability
LIFE.net 24x7 Remote Diagnostic System LIFE.net ensures that your critical power
protection system is maintained in an optimum state of readiness at all times.
LIFE.net maintenance program provides remote diagnosis, monitoring and
management of the operational status of UPS and power distribution system,
LIFE.net provides early warning of any alarm condition or out of tolerance status,
allowing effective proactive maintenance and fast incident response, for complete
security and peace of mind.
Maximise
Availability
Pre-emptive
maintenance
Reduce
operating costs
superior asset
management
Minimise
downtime
immediate
identification
of problem
Railway Application
Liebert® SXTM UPS is also available for
Railway Application in special ratings.
This specially deigned UPS has
flexibility of DC Bus and with higher
charger current. Assignalling system,
emergency lighting, ventilation
systems, Assignalling system,
emergency lighting, ventilation
systems, communication systems,
control infrastructure, ticketing or
passenger information systems and
traffic management all need continous
high quality electrical energy.
9
Liebert® SXTM
60kVA to 200kVA UPS
Three Phase Input, Three Phase Output
Specifications
System Rating(kVA)
Output Active Power(kW)
Apparent Nominal Output Power(kVA)
Input
Nominal Input Voltage (V)(1)
Nominal Bypass Voltage(1) (V)
Bypass Voltage Range (%)
Nominal Input Frequency/Frequency Tolerance(Hz)
Input Current distortion(2)(3) (%)
Input Power factor(2)
Walk in Soft Start(Seconds)
Rectifier Hold OFF(Seconds)
DC Parameter
Battery Compatibility
Flexibility in battery blocks
Output
Nominal Output Voltage(V)
Output Voltage Stability by load variation 0-100% (%)
- Static
- Dynamic
Nominal Output Frequency (Hz)
Output Frequency variation (%)
- with mains synchronization
- with internal reference
Inverter Overload Capacity
Compatibility with loads
60
60
60
80
80
80
200
200
200
400 (380/415 Selectable, 3ph+N)
±1%
Complies with IEC/EN 62040-3, Class 1"
50 (60 Selectable)
±1 (2, 3, 4 Selectable)
±0.1
125% for 10 min and 150% for 1min
Any power factor (leading or lagging) up to 1
Without output derating:crest factor up to 3:1"
VFI SS 111
From 0 to +70° C
0-40
< 95%
IP20
RAL 7021
Up to 96% in Double Conversion Mode
Up to 98% in Digital Interactive Mode"
1900
1200
900
1000
UPS weight(kg) Approx. (without Transformer option)
400
66 dBA
530
66 dBA 1400
530
68 dBA 68 dBA 1. In case of a split bypass configuration primary input and bypass mains must have a common earth.
The Neutral conductor could be part of the bypass or primary mains but it must be present.
2. At nominal voltage, nominal frequency.
3. With input voltage at nominal value and with THDV ‹1%.
* Declared Power @ 250C
* Specification subject to change without prior notice
* Please note, All data shown may not be applicable simultaneous. Please contact Vertiv application engineer for details.
10
160
160
160
VRLA/Wet Acid/Ni-Cd
40-50 12V Monoblocks(240 Cells to 300 Cells) - 2V
Overall Efficency(for tolerance see IEC 60146-1-1)(%)
Noise level
120
120
120
400 (3 ph + N(1))
400 (380/415 Selectable, 3Ph+N)
±10(5 to 15 Selectable)
50 (60 Selectable)/±10 (Selectable)
≤3
≥0.98
10 (1 to 90 Selectable)
10 (1 to 180 Selectable)
General
Classification according to IEC/EN 62040-3
Storage
Operating Temperature(°C)
Relative humidity(without condensation at 20°C(%))
Protection Level
Frame Colour
Dimensions and Weight
Height(mm)
Width(mm)
Depth(mm)
100
100
100
650
700 75 dBA 74.5 dBA VertivCo.com I E-mail : marketing.india@vertivco.com I Toll free : 1-800-2096070
Vertiv Energy Private Limited I Plot C-20, Rd No.19, Wagle Ind Estate, Thane (W), 400604. India
© 2017 Vertiv Co. All rights reserved.