PW6C... - Torfbud - Wagi elektroniczne.com

Single point load cells
Special features
− Accuracy class C3 with OIML-R60
test report
− Off center load compensated
(OIML R 76)
− Max. cpapacities: 3 kg ... 40 kg
− Degree of protection IP67
(according to EN 60 529)
− Shielded connection cable
− Optimized for static weighing
applications
Optional:
− Connection cable in six wire
circuit
− Different cable lengths
− Aligned output, suitable for
connection in parallel
Dimensions (in mm; 1 mm = 0.03937 inches)
Connection cable (see page 3)
Identification plate
22"0.2
Load direction
1−PW6CMR/xxKG−1
Plug (see page 3)
130"0.2
12
350+20
55"5
25.4"0.2*
15"0.1
106"0.2
4xM6
Mounting:
Fillister-head bolt M6−8.8
Tightening torque: 10 N⋅m
* PW6CC3MR/40 kg: 30
B1994-1.0 en
Data Sheet
PW6C...
Specifications
Max. platform size
mm
300 x 300
mV/V
2.2 "0.2
Zero signal
mV/V
0 "0.12
% of Cn
/ 10 K
"0.0175
5
10
% of Cn
"0.0166
% of Cn
"0.0166
Ratio of minimum dead load output
return (DR)
% of Cn
"0.0245
Off-center load error 3)
% of Cn
Ω
Ω
V
V
GΩ
"0.0233
300...500
300...500
5
1 ... 12
>2
°C [°F]
−10 ... +40 [+14 ... +104]
°C [°F]
°C [°F]
%
of Emax
mm
%
%max
of E
of Emax
mm
−10 ... +50 [+14 ... +122]
−25 ... +70 [−13 ... +158]
kg
0.25
Input resistance (RLC)
Output resistance (R0)
Reference excitation voltage (Uref)
Nom. range of excitation voltage (BU)
Isolation resistance (Ris) at 100 VDC
Nominal (rated) range of ambient temperature (BT)
Operating temperature range (Btu)
Storage temperature range (Btl)
Limit load (EL) *)
*) at max. eccentricity
Lateral load limit (Elq), static
Breaking load (Ed)
Nominal (rated) displacement at Emax
(snom), approx.
Weight (G), approx.
Degree of protection acc. to
EN 60 529 (IEC 529)
5
"0.0117
Non-linearity (dlin) 2)
Relative reversibility error (dhy)
2)
2
"0.0175
2
"0.0350
5
"0.0233
40
"0.0350
1
Sensitivity (Cn)
Temperature effect on sensitivity (TKC) 2)
in the temperature range
+20 ... +40 °C [+68 ... +104 °F]
−10 ... +20 °C [+14 ... +68 °F]
150
100
300
300
< 0.5
IP67
Material: Measuring body
Application protection
Cable sheath
1)
1
30
"0.0093
0.5
20
"0.0140
0.2
"0.0186
2
"0.0280
2
"0.0280
1
"0.0093
% of Cn
/ 10 K
0.5
"0.0140
Minimum LC verification interval (vmin)
(Accuracy class C3MR)
g
10
"0.0140
Minimum LC verification interval (vmin),
(Accuracy class C3MR)
% of Cn
/ 10 K
5
"0.0233
Temperature effect on zero
balance (TK0) (Accuracy class C3)
3
PW6C...
C3, C3MR
3000
15
"0.0093
Type
Accuracy class 1)
Maximum number of load cell intervals (nLC)
Maximum capacity (Emax)
kg
Minimum LC verification interval (vmin),
g
(Accuracy class C3)
Aluminum
Silicone caoutchouc
PVC
2)
According to OIMLR60 with PLC = 0.7
The values for linearity deviation (dlin), relative reversibility error (dhy) and temperature effect on sensitivity (TKC) are recommended values.
The sum of these values remain within the cumulated error limit acc. to OIML R60.
3)
According to OIML R76.
HBM
2
B1994-1.0 en
Wiring code
Connection with 4 wire cable (cable length: 0.35 m)
Detailed description of the Pancon plug (CE100F26-4), 4-pole
1
Wrap connection 1 (blue) = Excitation (+)
2
Wrap connection 2 (white) = Signal (+)
3
Wrap connection 3 (red) = Signal (−)
4
Shield (yellow) = Shield connected to load cell body
Wrap connection 4 (black) = Excitation (−)
blue marking
Connection wirh 6 wire cable (cable length, selectable: 0.35 m; 1.5 m; 3 m; 6 m)
Detailed description of the Pancon plug (CE100F26-6), 6-pole
1
Wrap connection 1 (white) = Signal (+)
2
Wrap connection 2 (red) = Signal (−)
3
Wrap connection 3 (black) = Excitation (−)
4
Wrap connection 4 (blue) = Excitation (+)
5
Wrap connection 5 (green) = Sense (+)
6
Shield (yellow) = Shield connected to load cell body
Wrap connection 6 (gray) = Sense (−)
blue marking
B1994-1.0 en
3
HBM
Ordering designations
PW6C... (Aluminum)
Type
Accuracy
Note
Capacity
3kg
5kg
10kg
15kg
20kg
30kg
40kg
PW6C
C3-MR (OIML)
Cable length 0.35m (4 wire)
Order no.
1-PW6CMR/3KG-1
1-PW6CMR/5KG-1
1-PW6CMR/10KG-1
1-PW6CMR/15KG-1
1-PW6CMR/20KG-1
1-PW6CMR/30KG-1
1-PW6CMR/40KG-1
K-PW6C-... (Aluminum), optional versions
Order no.
K-PW6C
Code Option 1: Mechanical version
N
Code Option 2: Accuracy
C3 C3 (OIML)
MR C3-MR (OIML)
Code
3
5
10
15
20
30
40
Option 3: Capacity
3kg
5kg
10kg
15kg
20kg
30kg
40kg
Code Option 4: NN
N
Code
4_0.35
6_0.35
6_1.5
6_3
6_6
Option 5: Cable length
0.35m (4 wire)
0.35m (6 wire)
1.5m (6 wire)
3m (6 wire)
6m (6 wire)
Code Option 6: Miscellaneous
without
N
2mV/V ±0.1% / 410 Ohms ±0.3 Ohms
A
(aligned output, suitable for connection in parallel)
K-PW6C - N -
-
- N -
Modifications reserved.
All details describe our products in general form only. They
are not to be understood as express warranty and do not
constitute any liability whatsoever.
B1994-1.0 en
-
Hottinger Baldwin Messtechnik GmbH
Im Tiefen See 45, D-64293 Darmstadt, Germany
Tel.: +49 6151 803-0 Fax: +49 6151 803 9100
Email: support@hbm.com Internet: www.hbm.com