CTW-UL12VDC9P5A Specifications
Model
Specification
Shape Dimension
Input
Output
CTW-UL 12VDC-9P/5A
60W12V5A9P
24.5×20.8×8.7cm
Input Voltage
Input Voltage Frequency
Average Input Current
Efficiency
Output Voltage
Output Current
Output Ripple Noise(Vpp)
≤3S Input 100Vac,Output rated
load
Type /Rating
PTC 1.1A/60V
When over voltage occurs, it will
Over voltage protection
switch to self-protection status to
protect the load.
When over current occurs, the
corresponding channel output will
automatically switch to selfOver current protection
protection status, and the other
channels output work normally,
when clearing of fault, it switches
back to normal.
When short-circuit occurs, individual
PTC fuse will break the circuit, when
short-circuit protection
clearing of fault, it switch back to
normal automatically.
Working Temperature
0℃~+50℃
Storage temperature
-20℃~+80℃
RH
20%~90%
Heat release
Natural heat dissipation
Input
Three-pin socket
Output
9channels output
Input to output
1500Vac/60S leakage current≤1.5ma
Input to FG
1500Vac/60S leakage current≤2.0ma
FG to output
500Vac/60S leakage current≤1.5ma
Input to output
≥20MΩ/500VDC@25℃
≤0.12ma @AC110V(220V)/25℃
reply time of starting up
Fuse
Protection
Circumstances
Connection
Dielectric Strength
Insulating strength
Leakage Current
88~264VAC
50Hz~60Hz
100Vac≤1.0A
≥80%
12VDC±5%
5A,9channels for 9 sets load
80mVp-p@25℃/Rated input voltage
& Output rated load
RG
Inspection
Equipment
≤0.011Ω@DC8V/25A/25℃
YF9901 Digital Power Meter MW –MOS-620 20MHz
Oscillograph
DZ2672A Hi-pot Tester
VC9802A DMM
IT815 300W/0-120V Electronic Load DZ2620 Leak Resistance
Tester
WB2678A RG Tester
Download PDF