CTW-UL12VDC9P5A Specifications Model Specification Shape Dimension Input Output CTW-UL 12VDC-9P/5A 60W12V5A9P 24.5×20.8×8.7cm Input Voltage Input Voltage Frequency Average Input Current Efficiency Output Voltage Output Current Output Ripple Noise(Vpp) ≤3S Input 100Vac,Output rated load Type /Rating PTC 1.1A/60V When over voltage occurs, it will Over voltage protection switch to self-protection status to protect the load. When over current occurs, the corresponding channel output will automatically switch to selfOver current protection protection status, and the other channels output work normally, when clearing of fault, it switches back to normal. When short-circuit occurs, individual PTC fuse will break the circuit, when short-circuit protection clearing of fault, it switch back to normal automatically. Working Temperature 0℃~+50℃ Storage temperature -20℃~+80℃ RH 20%~90% Heat release Natural heat dissipation Input Three-pin socket Output 9channels output Input to output 1500Vac/60S leakage current≤1.5ma Input to FG 1500Vac/60S leakage current≤2.0ma FG to output 500Vac/60S leakage current≤1.5ma Input to output ≥20MΩ/500VDC@25℃ ≤0.12ma @AC110V(220V)/25℃ reply time of starting up Fuse Protection Circumstances Connection Dielectric Strength Insulating strength Leakage Current 88~264VAC 50Hz~60Hz 100Vac≤1.0A ≥80% 12VDC±5% 5A,9channels for 9 sets load 80mVp-p@25℃/Rated input voltage & Output rated load RG Inspection Equipment ≤0.011Ω@DC8V/25A/25℃ YF9901 Digital Power Meter MW –MOS-620 20MHz Oscillograph DZ2672A Hi-pot Tester VC9802A DMM IT815 300W/0-120V Electronic Load DZ2620 Leak Resistance Tester WB2678A RG Tester