Rack Mount Series
UL Listed CCTV Power Supplies
Installation Guide
Models Include:
• R248UL
- 24VAC @ 3.5 amp (85VA)
-
or 28VAC @ 3 amp (85VA).
Eight (8) Fuse Protected Outputs.
• R248ULCB
- 24VAC @ 3.5 amp (85VA).
-
or 28VAC @ 3 amp (85VA).
Eight (8) PTC Protected Outputs.
Rev. 040506
Overview:
These Altronix Rack Mount CCTV Power Supplies provide 24VAC or 28VAC distributed via eight (8) fuse or
PTC protected outputs for powering CCTV Cameras, heaters and other video accessories.
Cu
rre
Nu
nt
m
b
e
PT r
C o
(C Pr f Ou
la o
t
Dr ss 2 tecte puts
y p d
W loc ow Ou
et ati er tp
u
o
Fu loca ns) limi ts
se tio . (C ted
Cl Pr ns la fo
as ot ). ss r
s e
3f
In 1 O cted
or
div u
(m idu tpu
a a ts
ex x p l O
c er u
Fu eed out tput
se tot pu Cu
Ra al t - rr
tin out no ent
gs pu t to
Pr
tc
im
ur
Fu ary
ren
se In
t)
Ra -l
tin ine
gs
11
5V
In AC
pu 5
Ag t Cu 0/60
en rre Hz
nt
Li cy
sti
ng
s
To
ta
(P l Ou
ow tp
er) ut
Altronix
Model Number
Ou
tp
ut
Vo
lta
ge
Rack Mount Configuration Reference Chart:
24VAC 3.5 amp
R248UL
28VAC
3 amp
8
--
Yes
3.5
amp
3.5
amp
3.5 amp/
250V
.85
amp
Yes
--
--
8
2.5
amp
--
3.5 amp/
250V
.85
amp
24VAC 3.5 amp
R248ULCB
28VAC
3 amp
Yes
Specifications:
• UL Listed for Commercial
Closed-Circuit Television Equipment (UL2044).
CUL Listed - CSA Standard C22.2 No.1-98, Audio,
Video and Similar Equipment.
• 24VAC or 28VAC outputs.
• Surge suppression.
• Individual power LED indicators.
• Illuminated power disconnect circuit breaker
with manual reset.
• Spare fuse provided (fuse protected model only).
• Unit maintains camera synchronization.
• Ease of installation saves time and eliminates
costly labor.
• 2U rack mount chassis for use in standard EIA 19” rack.
• Removable terminal blocks w/locking screw flanges.
Rack Dimensions:
3.25”H x 19.125”W x 8.5”D
Installation Instructions:
1. Mount unit in desired rack location (Space unit at least 3” from any video monitors), Do not obstruct side air vents.
2. Set power disconnect circuit breaker to OFF position (Fig. 1D, pg. 3).
3 All units are factory set for 24VAC operation.
For 28VAC operation, adjust unit prior to mounting and applying power as follows:
Change the wire position so that the wire marked [28V] is connected to the terminal marked [P] and
the wire marked [24V] is connected to the terminal marked [S].
Note: R248ULCB set for 28VAC operation is not Class 2 Rated, not power limited.
4. Plug power cord into grounded 115VAC 50/60 Hz receptacle (Fig. 1C, pg. 3), ground should be connected
as indicated in (Fig. 1E, pg. 3).
5. Set power disconnect circuit breaker to RESET (ON) position (Fig. 1D, pg. 3).
6. Measure output voltage before connecting devices. This helps avoid potential damage.
All terminals with common suffix (P) “1P, 2P...” are the same polarity.
6. Set power disconnect circuit breaker to OFF position (Fig. 1D, pg. 3).
7. Connect devices to removable terminal blocks marked [1P & 1N through 8P & 8N] for eight (8) output models
(Fig. 1A, pg. 3).
When wiring is completed on terminal blocks they can be locked down by tightening screw flanges.
8. Upon completion of wiring, set power disconnect circuit breaker to RESET (ON) position (Fig. 1D, pg. 3).
-2-
Fig. 1
Fig. 1B
Fig. 1A
Fig. 1C
Fig. 1D
Fuse
Removable Terminal
Block
Strain Relief
Line Cord
Illuminated
Power Disconnect
Circuit Breaker with
manual reset
S
P
P N
N
XFMR
ALTRONIX CORP.
BROOKLYN, NY 11220
MADE IN USA
Divider
PTC1
Used
on PTC
Models
AC Power
LED's
AC Power
LED's
24VAC Output
(Factory Set)
S
P
28VAC Output
N
S
P
N
24VAC
28VAC
24VAC
28VAC
(Green Wire
Earth GND)
Fig. 1E
9. Green power LEDs on faceplate will illuminate when power is present. When an output is in a trouble condition
(blown fuse or tripped PTC) the corresponding LED will not be illuminated (Fig. 1, pg. 3).
a. Blown fuse (R248UL) - Set power disconnect circuit breaker on back of unit to the OFF position (Fig. 1D, pg. 3).
Remove front faceplate to access fuses. Replace with fuses rated @ 3.5A/250VA (Altronix model # Fuse1).
b.Tripped PTC (R248ULCB) - To reset PTC, set power disconnect circuit breaker on back of unit to the
OFF position. After approximately 30 secs. set power disconnect circuit breaker to the ON (RESET) position
(Fig. 1D, pg. 3).
10. Illuminated power disconnect circuit breaker with manual reset:
OFF position - Switch not Illuminated. Outputs not powered.
RESET (ON) position - Circuit breaker illuminated. Outputs powered.
Circuit breaker tripped - Circuit breaker is not Illuminated. Power LEDs on faceplate are not illuminated.
Outputs not powered.
To reset circuit breaker set power disconnect circuit breaker to RESET (ON) position (Fig. 1D, pg. 3).
Note: Do not exceed units electrical load ratings as indicated in reference chart (pg. 2).
Do not place mechanical load on unit. Unit is designed optimally for normal data room office installations.
Data racks should always be properly ventilated.
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture.
This installation should be made by qualified service personnel and should conform to all local codes
and in accordance with the National Electrical Code.
-3-
3.5A 250V
For fuse protected models:
Replace fuses with the same type and rating 3.5A/250V.
The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the
presence of an insulated “DANGEROUS VOLTAGE” within the products enclosure that may be of sufficient
magnitude to constitute an electric shock.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the literature accompanying the appliance.
CAUTION: To reduce the risk of electric shock do not open enclosure. There are
no user serviceable parts inside. Refer servicing to qualified service personnel.
Rack Mechanical Drawing & Dimensions
3.25”H x 19.125”W x 8.5”D
View from back
BACK
3.125"
32
N
31
P
N
30
P
N
29
P
N
28
P
N
27
P
N
26
P
N
24
25
P
N
P
N
23
P
N
21
22
P
N
P
N
20
P
N
18
19
P
N
P
N
P
16
17
N
P
N
P
15
N
P
14
N
P
13
N
P
12
N
P
11
N
10
P
N
P
8
9
N
P
N
7
P
N
6
P
N
4
5
P
N
P
N
3
P
N
2
P
N
1
P
N
P
17.625"
BOTTOM
8.5"
View from front
FACEPLATE
19.125"
.75"
Altronix is not responsible for any typographical errors.
Altronix Corp.
140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056
web site: www.altronix.com, e-mail: info@altronix.com, Lifetime Warranty, Made in U.S.A.